User guide | Cisco Systems OL-21636-01 Security Camera User Manual

Cisco IP Solution Center
L2VPN and Carrier Ethernet
User Guide, 6.0
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-21636-01
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public
domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at
www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1005R)
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display
output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in
illustrative content is unintentional and coincidental.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
Copyright © 2010 Cisco Systems, Inc. All rights reserved.
C O N T E N T S
About This Guide
CHAPTER
1
Getting Started
Overview
xi
1-1
1-1
Installing ISC and Configuring the Network
1-1
Configuring the Network to Support Layer 2 Services
1-2
Setting Up Basic ISC Services 1-2
Setting Up Providers, Customers, and Devices 1-2
Setting Up the N-PE Loopback Address 1-3
Setting Up ISC Resources for L2VPN and VPLS Services
Setting Up NPCs 1-3
Setting Up VPNs 1-3
Working with L2VPN and VPLS Policies and Service Requests
A Note on Terminology Conventions
CHAPTER
2
Setting Up the ISC Services
1-3
1-4
1-4
2-1
Creating Target Devices and Assigning Roles (N-PE or U-PE)
2-1
Configuring Device Settings to Support ISC 2-2
Configuring Switches in VTP Transparent Mode 2-2
Setting the Loopback Addresses on N-PE Devices 2-2
Setting Up Devices for IOS XR Support 2-3
Defining a Service Provider and Its Regions
Defining Customers and Their Sites
Defining VPNs
2-3
2-4
2-4
Creating Access Domains
Creating VLAN Pools
2-5
Creating a VC ID Pool
2-7
2-4
Creating Named Physical Circuits 2-8
Creating NPCs Through an NPC GUI Editor 2-8
Creating a Ring-Only NPC 2-9
Terminating an Access Ring on Two N-PEs 2-10
Creating NPC Links Through the Autodiscovery Process
2-10
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
iii
Contents
Creating and Modifying Pseudowire Classes for IOS XR Devices 2-10
Creating a Pseudowire Class 2-11
Modifying a Pseudowire Class Object 2-12
Configuring the Transport Mode When Pseudowire Classes are Not Supported
Defining L2VPN Group Names for IOS XR Devices
CHAPTER
3
Creating a FlexUNI/EVC Ethernet Policy
2-13
2-14
3-1
Overview of FlexUNI/EVC Support in ISC 3-1
FlexUNI/EVC Features 3-2
Platform Support for FlexUNI/EVC in ISC 6.0 3-3
IOS Platform Support 3-3
IOS XR Platform Support 3-4
Device Roles with FlexUNI/EVC 3-5
Topology Overview for FlexUNI/EVC 3-5
CE Directly Connected and FlexUNI 3-5
CE Directly Connected and No FlexUNI 3-5
CE Not Directly Connected and FlexUNI 3-5
CE Not Directly Connected and No FlexUNI 3-6
A Note on Checking of Configurations 3-6
Defining the FlexUNI/EVC Ethernet Policy
Setting the Service Options
3-6
3-8
Setting the FlexUNI Attributes 3-10
Setting the Service Attributes 3-11
Setting the VLAN Matching Criteria Attributes 3-13
Setting the VLAN Rewrite Criteria Attributes 3-14
CHAPTER
4
Setting the Interface Attributes
3-16
Enabling Template Association
3-23
Managing a FlexUNI/EVC Ethernet Service Request
Introducing FlexUNI/EVC Service Requests
Creating a FlexUNI/EVC Service Request
4-1
4-1
4-2
Setting the Service Request Details 4-2
Pseudowire Core Connectivity 4-3
VPLS Core Connectivity 4-5
Local Core Connectivity 4-7
Setting up Links to the N-PE 4-9
Setting Direct Connect Links 4-10
Setting Links with L2 Access Nodes
4-20
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
iv
OL-21636-01
Contents
Modifying the FlexUNI/EVC Service Request
4-21
Using Templates and Data Files with a FlexUNI/EVC Ethernet Service Request
Saving the FlexUNI/EVC Service Request
CHAPTER
5
4-23
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Overview
4-22
5-1
5-1
Defining the FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Service Options
5-2
5-4
Setting the ATM Interface Attributes
5-6
Setting the FlexUNI Attributes 5-7
Setting the Service Attributes 5-8
Setting the VLAN Matching Criteria Attributes 5-10
Setting the VLAN Rewrite Criteria Attributes 5-10
CHAPTER
6
Setting the Interface Attributes
5-12
Enabling Template Association
5-19
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Overview
6-1
6-1
Creating a FlexUNI/EVC ATM-Ethernet Interworking Service Request
6-2
Setting the Service Request Details 6-3
Pseudowire Core Connectivity 6-3
Local Core Connectivity 6-6
Setting up Links to the N-PE 6-8
Setting Direct Connect Links 6-8
Setting the ATM Link Attributes 6-18
Setting Links with L2 Access Nodes 6-22
Modifying the FlexUNI/EVC Service Request
6-23
Using Templates and Data Files with a FlexUNI/EVC Service Request
Saving the FlexUNI/EVC Service Request
CHAPTER
7
Creating an L2VPN Policy
Defining an L2VPN Policy
6-24
6-24
7-1
7-1
Defining an Ethernet ERS (EVPL) Policy with a CE
7-3
Defining an Ethernet ERS (EVPL) Policy without a CE
Defining an Ethernet EWS (EPL) Policy with a CE
7-15
Defining an Ethernet EWS (EPL) Policy without a CE
Defining a Frame Relay Policy with a CE
7-9
7-22
7-28
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
v
Contents
Defining a Frame Relay Policy without a CE
Defining an ATM Policy with a CE
7-33
Defining an ATM Policy without a CE
CHAPTER
7-36
Managing an L2VPN Service Request
8
7-31
8-1
Introducing L2VPN Service Requests
8-1
Creating an L2VPN Service Request 8-2
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request with a CE 8-2
Creating an EWS (EPL) L2VPN Service Request with a CE 8-8
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request without a CE 8-11
Creating an EWS (EPL) L2VPN Service Request without a CE 8-16
Modifying the L2VPN Service Request
Saving the L2VPN Service Request
CHAPTER
Creating a VPLS Policy
9
Defining a VPLS Policy
8-20
8-26
9-1
9-1
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE
9-3
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE
Defining an MPLS/EMS (EP-LAN) Policy with a CE
9-7
9-11
Defining an MPLS/EMS (EP-LAN) Policy without a CE
9-16
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
9-22
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
9-32
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
CHAPTER
10
Managing a VPLS Service Request
10-1
Introducing VPLS Service Requests
10-1
Creating a VPLS Service Request
9-37
10-2
Creating a VPLS Service Request with a CE
10-2
Creating a VPLS Service Request without a CE
Modifying the VPLS Service Request
Using the Bridge Domain ID Attribute
Saving the VPLS Service Request
9-27
10-6
10-10
10-13
10-14
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
vi
OL-21636-01
Contents
CHAPTER
11
Deploying, Monitoring, and Auditing Service Requests
11-1
Deploying Service Requests 11-1
Pre-Deployment Changes 11-1
Service Deployment 11-2
Verifying Service Requests 11-3
Service Request States 11-4
Viewing Service Request Details 11-7
Links 11-8
History 11-9
Configlets 11-9
Monitoring Service Requests
Auditing Service Requests
11-10
11-12
CHAPTER
12
Using Autodiscovery for L2 Services
CHAPTER
13
Generating L2 and VPLS Reports
Overview
12-1
13-1
13-1
Accessing L2 and VPLS Reports
13-1
L2 and VPLS Reports 13-2
L2 End-to-End Wire Report 13-3
L2 PE Service Report 13-6
L2 VPN Report 13-7
VPLS Attachment Circuit Report 13-8
VPLS PE Service Report 13-10
VPLS VPN Report 13-11
Creating Custom L2 and VPLS Reports
APPENDIX
A
Sample Configlets
Overview
13-11
A-1
A-2
ERS (EVPL) (Point-to-Point)
A-4
ERS (EVPL) (Point-to-Point, UNI Port Security)
ERS (EVPL) (1:1 VLAN Translation)
A-7
ERS (EVPL) (2:1 VLAN Translation)
A-8
A-5
ERS (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device)
ERS (EVPL) (NBI Enhancements for L2VPN, IOS Device)
ERS (EVPL) or EWS (EPL) (IOS XR Device)
A-9
A-10
A-11
ERS (EVPL) and EWS (EPL) (Local Connect on E-Line)
A-14
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
vii
Contents
ERS (EVPL), EWS (EPL), ATM, or Frame Relay (Additional Template Variables for L2VPN, IOS and IOS XR
Device) A-15
EWS (EPL) (Point-to-Point)
A-16
EWS (EPL) (Point-to-Point, UNI Port Security, BPDU Tunneling)
EWS (EPL) (Hybrid)
A-17
A-19
EWS (EPL) (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device)
EWS (EPL) (NBI Enhancements for L2VPN, IOS Device)
ATM over MPLS (VC Mode)
A-24
ATM over MPLS (VP Mode)
A-25
A-22
A-23
ATM (Port Mode, Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device)
Frame Relay over MPLS
Frame Relay (DLCI Mode)
A-26
A-27
A-28
VPLS (Multipoint, ERMS/EVP-LAN)
A-29
VPLS (Multipoint, EMS/EP-LAN), BPDU Tunneling)
A-30
FlexUNI/EVC (Pseudowire Core Connectivity, UNI Port Security)
A-31
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, without Port Security, with Bridge Domain)
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, and Pseudowire Tunneling)
FlexUNI/EVC (VPLS Core Connectivity, UNI Port Security)
FlexUNI/EVC (VPLS Core Connectivity, no UNI Port Security)
A-33
A-34
A-35
FlexUNI/EVC (Local Connect Core Connectivity, UNI Port Security)
A-36
FlexUNI/EVC (Local Connect Core Connectivity, UNI, no Port Security, Bridge Domain)
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge Domain, Pseudowire on SVI)
A-38
A-39
FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge Domain, no Pseudowire on SVI)
FlexUNI/EVC (AutoPick Service Instance Name)
A-32
A-40
A-41
FlexUNI/EVC (No AutoPick Service Instance Name, No Service Instance Name)
A-42
FlexUNI/EVC (User-Provided Service Instance Name, Pseudowire Core Connectivity)
FlexUNI/EVC (User-Provided Service Instance Name, Local Core Connectivity)
A-44
FlexUNI/EVC (User-Provided Service Instance Name, VPLS Core Connectivity)
A-45
A-43
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Point-to-Point Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Multipoint Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit)
A-47
A-48
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Multipoint Circuit)
A-49
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Multipoint Circuit)
A-50
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit)
A-46
A-51
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit)
A-52
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Multipoint Circuit)
A-53
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
viii
OL-21636-01
Contents
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit)
A-54
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, with Bridge
Domain) A-55
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, with Bridge
Domain) A-56
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, no Bridge
Domain) A-57
APPENDIX
B
Working with Templates and Data Files
B-1
Overview B-1
Summary of Template Manager Features
Template and Data File Workflow B-3
B-1
Using Templates with ISC Policies B-4
Overview of Template Support in ISC Policies B-4
Associating Templates and Data Files to a Policy B-5
Selectively Determining Templates for U-PE and PE-AGG Device Roles
Using Templates with Service Requests B-10
Overview of Template Use in Service Requests B-10
Associating Templates to a Service Request B-11
Associating Subtemplates During Service Provisioning B-11
Creating Data Files During Service Request Creation B-12
Using Negate Templates to Decommission Template Configurations
Using Templates and Data Files with Service Requests B-14
Choosing a Template in the Service Request Workflow B-14
Creating a Data File in the Service Request Workflow B-16
Decommissioning Service Requests with Added Templates B-18
Viewing Templates from the Service Requests Window B-18
APPENDIX
C
Setting Up VLAN Translation
C-1
VLAN Translation Overview
C-1
B-9
B-13
Setting Up VLAN Translation C-1
Creating a Policy C-2
Creating a Service Request C-3
No VLAN Translation C-3
1:1 VLAN Translation C-3
2:1 VLAN Translation C-4
Modifying a Service Request C-5
Deleting a Service Request C-5
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
ix
Contents
Platform-Specific Usage Notes C-6
VLAN Translation on the 3750 C-6
VLAN Translation on the 7600 C-6
Failed Service Requests When Hardware Does Not Support VLAN Translation
APPENDIX
D
Terminating an Access Ring on Two N-PEs
Overview
D-1
D-1
Setting Up an NPC Access Ring with Two N-PEs
APPENDIX
E
C-6
D-3
Using N-PE Redundancy in FlexUNI/EVC Service Requests
D-3
Additional Network Configurations and Sample Configlets
Example 1: Pseudowire Connectivity (A) D-5
Example 2: Pseudowire Connectivity (B) D-6
Example 3: Pseudowire Connectivity (C) D-8
Example 4: VPLS Connectivity D-9
D-5
ISC Layer 2 VPN Concepts
E-1
Layer 2 Terminology Conventions E-1
MEF Terminology Conventions E-1
Mapping MEF Terminologies to Network Technologies
ISC Terminology and Supported Network Types E-4
E-3
L2VPN Service Provisioning E-5
Point-to-Point Ethernet (EWS and ERS) (EPL and EVPL)
ATM over MPLS (ATMoMPLS) E-8
Frame Relay over MPLS (FRoMPLS) E-9
E-5
VPLS Service Provisioning E-10
Multipoint EWS (EP-LAN) for an MPLS-Based Provider Core E-11
Multipoint ERS (EVP-LAN) for an MPLS-Based Provider Core E-11
Topology for MPLS-Based VPLS E-11
VPLS for an Ethernet-Based (L2) Provider Core E-13
Multipoint EWS (EP-LAN) for an Ethernet-Based Provider Core E-13
Multipoint ERS (EVP-LAN) for an Ethernet-Based Provider Core E-13
Topology for Ethernet-Based VPLS E-13
INDEX
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
x
OL-21636-01
About This Guide
This preface contains the following sections:
•
Objective, page xi
•
Audience, page xi
•
Organization, page xi
•
Related Documentation, page xii
•
Obtaining Documentation and Submitting a Service Request, page xiv
Objective
The Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0 contains information about
creating L2VPN or VPLS policies and creating and deploying L2VPN or VPLS services using the Cisco
IP Solution Center (ISC).
Audience
This guide is designed for service provider network managers and operators who are responsible for
provisioning L2VPN or VPLS for their customers. Network managers and operators should be familiar
with the following topics:
•
Basic concepts and terminology used in internetworking.
•
Layer 2 Virtual Private Network (L2VPN), Virtual Private LAN Service (VPLS), VPN,
Multiprotocol Label Switching (MPLS), and terms and technology.
•
Network topologies and protocols.
Organization
This guide is organized as follows:
•
Chapter 1, “Getting Started,” provides information on getting started tasks for using the L2VPN
component of the Cisco IP Solution Center (ISC).
•
Chapter 2, “Setting Up the ISC Services,” provides information on setting up the ISC service.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
xi
About This Guide
•
Chapter 3, “Creating a FlexUNI/EVC Ethernet Policy,” provides information on creating a
FlexUNI/EVC policy.
•
Chapter 4, “Managing a FlexUNI/EVC Ethernet Service Request,” provides information on
creating, deploying, monitoring, and saving FlexUNI/EVC service requests.
•
Chapter 5, “Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy,” provides information on
creating a FlexUNI/EVC ATM-Ethernet Interworking policy.
•
Chapter 6, “Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request,” provides
information on creating, deploying, monitoring, and saving FlexUNI/EVC ATM-Ethernet
Interworking service requests.
•
Chapter 7, “Creating an L2VPN Policy,” provides information on creating an L2VPN policy.
•
Chapter 8, “Managing an L2VPN Service Request,” provides information on creating, deploying,
monitoring, and saving a L2VPN service requests.
•
Chapter 9, “Creating a VPLS Policy,” provides information on creating a VPLS policy.
•
Chapter 10, “Managing a VPLS Service Request,” provides information on creating, deploying,
monitoring, and saving VPLS service requests.
•
Chapter 11, “Deploying, Monitoring, and Auditing Service Requests,” provides information on how
to deploy, manage and audit service requests, and how to access task logs.
•
Chapter 12, “Using Autodiscovery for L2 Services,” provides an overview of L2 service discovery.
•
Chapter 13, “Generating L2 and VPLS Reports,” provides information on how to set up, run, and
format L2 and VPLS reports.
•
Appendix A, “Sample Configlets,” provides sample configlets for various network scenarios.
•
Appendix B, “Working with Templates and Data Files,” provides information about using templates
and data files in ISC policies and service requests.
•
Appendix C, “Setting Up VLAN Translation,” provides information on how to set up VLAN
translation for L2VPN ERS services.
•
Appendix D, “Terminating an Access Ring on Two N-PEs,” describes how to terminate an access
ring on two N-PEs.
•
Appendix E, “ISC Layer 2 VPN Concepts,” provides an overview of the major concepts that
structure the ISC L2VPN or VPLS service.
•
Index
Related Documentation
The entire documentation set for Cisco IP Solution Center, can be accessed at:
http://www.cisco.com/en/US/products/sw/netmgtsw/ps4748/tsd_products_support_series_home.html
or at:
http://www.cisco.com/go/isc
Tip
To copy and paste a two-line URL into the address field of your browser, you must copy and paste each
line separately to get the entire URL without a break.
The following documents comprise the ISC documentation set:
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
xii
OL-21636-01
About This Guide
General documentation (in suggested reading order)
•
Cisco IP Solution Center Getting Started and Documentation Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/roadmap/docguide.html
•
Release Notes for Cisco IP Solution Center, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/release/notes/relnotes.html
•
Cisco IP Solution Center Installation Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/installation/guide/
installation.html
•
Cisco IP Solution Center Infrastructure Reference, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/infrastructure/reference/
guide/infrastructure.html
•
Cisco IP Solution Center System Error Messages, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/system/messages/
messages.html
•
Cisco IP Solution Center Third Party and Open Source Copyrights, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/third_party/open_source/
ISC_Third_Party_and_Open_Source_Copyrights60.html
Application and technology documentation (listed alphabetically)
•
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/l2vpn/user/guide/
l2vpn60book.html
•
Cisco IP Solution Center MPLS Diagnostics Expert Failure Scenarios Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/mpls_failure_scenarios/user/
guide/mdefs.html
•
Cisco IP Solution Center MPLS Diagnostics Expert User Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/mpls_diagnostics/user/guide/
mdeuser.html
•
Cisco IP Solution Center MPLS VPN User Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/mpls_vpn/user/guide/
mpls60book.html
•
Cisco IP Solution Center Traffic Engineering Management User Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/traffic_management/user/
guide/tem.html
API Documentation
•
Cisco IP Solution Center API Programmer Guide, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/developer/guide/
api_gd.html
•
Cisco IP Solution Center API Programmer Reference, 6.0.
http://www.cisco.com/en/US/docs/net_mgmt/ip_solution_center/6.0/developer/reference/
xmlapi.zip
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
xiii
About This Guide
Note
All documentation might be upgraded over time. All upgraded documentation will be available at the
same URLs specified in this document.
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and
revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free
service and Cisco currently supports RSS Version 2.0.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
xiv
OL-21636-01
CH A P T E R
1
Getting Started
This chapter provides a road map to help you get started using the L2VPN component in ISC 6.0. It
contains the following sections:
•
Overview, page 1-1
•
Installing ISC and Configuring the Network, page 1-1
•
Configuring the Network to Support Layer 2 Services, page 1-2
•
Setting Up Basic ISC Services, page 1-2
•
Working with L2VPN and VPLS Policies and Service Requests, page 1-4
•
A Note on Terminology Conventions, page 1-4
Overview
Before you can use the L2VPN component to provision Layer 2 services (L2VPN or VPLS), you must
complete several installation and configuration steps, as outlined in this chapter. In addition, you should
be familiar with basic concepts for ISC and L2VPN (or VPLS) services. The following sections provide
a summary of the key tasks you must accomplish to be able to provision L2VPN or VPLS services using
ISC. You can use the information in this chapter as a checklist. Where appropriate, references to other
sections in this guide or to other guides in the ISC documentation set are provided. See the referenced
documentation for more detailed information. After the basic installation and configuration steps are
completed for both ISC and the L2VPN component, see the subsequent chapters of this guide to create
and provision L2VPN or VPLS services.
Installing ISC and Configuring the Network
Before you can use the L2VPN module in ISC to provision L2VPN or VPLS services, you must first
install ISC and do the basic network configuration required to support ISC. Details on these steps are
provided in the Cisco IP Solution Center Installation Guide, 6.0. See that guide for information about
ISC installation and general network configuration requirements.
Note
To use the L2VPN component within ISC, you must purchase and activate the L2VPN license.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
1-1
Chapter 1
Getting Started
Configuring the Network to Support Layer 2 Services
Configuring the Network to Support Layer 2 Services
In addition to basic network configuration required for ISC, you must perform the following network
configuration steps to support Layer 2 services. Information on doing these steps is not provided in the
ISC documentation. See the documentation for your devices for information on how to perform these
steps.
1.
Enable MPLS on the core-facing interfaces of the N-PE devices attached to the provider core.
2.
Set up /32 loopback addresses on N-PE devices. These loopback addresses should be the termination
of the LDP connection(s).
3.
Set all Layer 2 devices (switches) to VTP transparent mode. This ensures that none of the switches
will operate as VLAN servers and will prevent VLAN information from automatically propagating
through the network.
Setting Up Basic ISC Services
After the basic network configuration tasks are completed to support ISC and L2 services, you use ISC
to define elements in the ISC repository, such as providers and regions, customers and sites, devices,
VLAN and VC pools, NPCs, and other resources that are necessary to provision L2 services. Detailed
steps to perform general ISC tasks are covered in the Cisco IP Solution Center Infrastructure Reference,
6.0. You can also find a summary of some important ISC set up tasks in this guide in Chapter 2, “Setting
Up the ISC Services.” The information below is a checklist of basic ISC services you must set up before
provisioning L2 services.
Setting Up Providers, Customers, and Devices
Perform the following steps to set up providers, customers, and devices in the ISC repository. These are
global resources that can be used by all ISC services.
1.
Set up service providers and regions. The region is important because a single provider could have
multiple networks. The region is used as a further level of differentiation to allow for such
circumstances. To create a provider and a region, see the Cisco IP Solution Center Infrastructure
Reference, 6.0. See also Defining a Service Provider and Its Regions, page 2-3.
2.
Set up customers and customer sites. A customer is a requestor of a VPN service from an ISP.
Each customer can own many customer sites. Each customer site belongs to one and only one
Customer and can own many CEs. For detailed steps to create customers and sites, see the Cisco IP
Solution Center Infrastructure Reference, 6.0. See also Defining Customers and Their Sites,
page 2-4.
3.
Import or add raw devices. Every network element that ISC manages must be defined as a device
in the ISC repository. An element is any device from which ISC can collect information. In most
cases, devices are Cisco IOS routers and switches. You can set up devices in ISC manually, through
autodiscovery, or through importing device configuration files. For detailed steps for importing,
adding, and collecting configurations for devices, see the Cisco IP Solution Center Infrastructure
Reference, 6.0. See also Chapter 12, “Using Autodiscovery for L2 Services.”
4.
Assign devices roles as PE or CE. After devices are created in ISC, you must define them as
customer (CE) or provider (PE) devices. You do this by editing the device attributes on individual
devices or in batch editing through the ISC inventory manager. To set device attributes, see the Cisco
IP Solution Center Infrastructure Reference, 6.0.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
1-2
OL-21636-01
Chapter 1
Getting Started
Setting Up Basic ISC Services
Setting Up the N-PE Loopback Address
Within ISC, you must set the loopback address on the N-PE device(s). For details about this procedure,
see Setting the Loopback Addresses on N-PE Devices, page 2-2.
Setting Up ISC Resources for L2VPN and VPLS Services
Some ISC resources, such as access domains, VLAN pools, and VC pools are set up to support ISC
L2VPN and VPLS services only. Perform the following steps to set up these resources.
1.
Create access domain(s). For L2VPN and VPLS, you create an access domain if you provision an
Ethernet-based service and want ISC to automatically assign a VLAN for the link from the VLAN
pool. For each Layer 2 access domain, you need a corresponding access domain object in ISC.
During creation, you select all the N-PE devices that are associated with this domain. Later, one
VLAN pool can be created for an access domain. For detailed steps to create access domains, see
the Cisco IP Solution Center Infrastructure Reference, 6.0. See also Creating Access Domains,
page 2-4.
2.
Create VLAN pool(s). A VLAN pool is created for each access domain. For L2VPN and VPLS,
you create a VLAN pool so that ISC can assign a VLAN to the links. VLAN ID pools are defined
with a starting value and a size. For detailed steps to create VLAN pools, see the Cisco IP Solution
Center Infrastructure Reference, 6.0. See also Creating VLAN Pools, page 2-5.
3.
Create VC pool(s).VC ID pools are defined with a starting value and a size of the VC ID pool. A
given VC ID pool is not attached to any inventory object (a provider or customer). Create one VC
ID pool per network. For detailed steps to create VC pools, see the Cisco IP Solution Center
Infrastructure Reference, 6.0. See also Creating a VC ID Pool, page 2-7.
Setting Up NPCs
Before creating an L2VPN or VPLS service request, you must predefine the physical links between CEs
and PEs or between U-PEs and N-PEs. The Named Physical Circuit (NPC) represents a link going
through a group of physical ports. Thus, more than one logical link can be provisioned on the same NPC.
Therefore, the NPC is defined once but used by several L2VPN or VPLS service requests. For detailed
steps to create NPCs, see the Cisco IP Solution Center Infrastructure Reference, 6.0. See also Creating
Named Physical Circuits, page 2-8.
Setting Up VPNs
You must define VPNs before provisioning L2VPN or VPLS services. In L2VPN, one VPN can be
shared by different service types. In VPLS, one VPN is required for each VPLS instance. To define
VPNs, see the Cisco IP Solution Center Infrastructure Reference, 6.0. See also Defining VPNs,
page 2-4.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
1-3
Chapter 1
Getting Started
Working with L2VPN and VPLS Policies and Service Requests
Working with L2VPN and VPLS Policies and Service Requests
After you have set up providers, customers, devices, and resources in ISC, you are ready to create
L2VPN or VPLS policies, provision service requests (SRs), and deploy the services. After the service
requests are deployed you can monitor, audit and run reports on them. All of these tasks are covered in
this guide. To accomplish these tasks, perform the following steps.
1.
Review overview information about L2 services concepts. See Appendix E, “ISC Layer 2 VPN
Concepts”
2.
Set up a FlexUNI, L2VPN, or VPLS policy. See the appropriate chapter, depending on the type of
policy you want to create:
– Chapter 3, “Creating a FlexUNI/EVC Ethernet Policy.”
– Chapter 5, “Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy.”
– Chapter 7, “Creating an L2VPN Policy.”
– Chapter 9, “Creating a VPLS Policy.”
3.
Provision the FlexUNI, L2VPN, or VPLS service request. See the appropriate chapter, depending
on the type service request you want to provision:
– Chapter 4, “Managing a FlexUNI/EVC Ethernet Service Request.”
– Chapter 6, “Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request.”
– Chapter 8, “Managing an L2VPN Service Request.”
– Chapter 10, “Managing a VPLS Service Request.”
4.
Deploy the service request. See Chapter 11, “Deploying, Monitoring, and Auditing Service
Requests.”
5.
Check the status of deployed services. You can use one or more of the following methods:
– Monitor service requests. See Chapter 11, “Deploying, Monitoring, and Auditing Service
Requests.”
– Audit service requests. See Chapter 11, “Deploying, Monitoring, and Auditing Service
Requests.”
– Run L2 and VPLS reports. See Chapter 13, “Generating L2 and VPLS Reports.”
A Note on Terminology Conventions
The ISC GUI and this user guide use specific naming conventions for Ethernet services. These align
closely with the early MEF conventions. This is expected to be updated in future releases of ISC to
conform with current MEF conventions. For reference, the equivalent terms used by the MEF forum are
summarized in Table 1-1.
See Layer 2 Terminology Conventions, page E-1 for more information on terminology conventions and
how these align with underlying network technologies.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
1-4
OL-21636-01
Chapter 1
Getting Started
A Note on Terminology Conventions
Table 1-1
Ethernet Service Terminology Mappings
Term Used in ISC GUI and This User Guide
Current MEF Equivalent Term
L2VPN over MPLS Core
Ethernet Wire Service (EWS)
Ethernet Private Line (EPL)
Ethernet Relay Service (ERS)
Ethernet Virtual Private Line (EVPL)
ATM over MPLS (ATMoMPLS)
—
Frame Relay over MPLS (FRoMPLS)
—
VPLS Over MPLS Core
Ethernet Wire Service (EWS) or
Ethernet Multipoint Service (EMS)
Ethernet Private LAN (EP-LAN)
Ethernet Relay Service (ERS) or
Ethernet Relay Multipoint Service (ERMS)
Ethernet Virtual Private LAN (EVP-LAN)
VPLS over Ethernet Core
Ethernet Wire Service (EWS)
Ethernet Private LAN (EP-LAN)
Ethernet Relay Service (ERS)
Ethernet Virtual Private LAN (EVP-LAN)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
1-5
Chapter 1
Getting Started
A Note on Terminology Conventions
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
1-6
OL-21636-01
CH A P T E R
2
Setting Up the ISC Services
To create L2VPN, VPLS, and FlexUNI/EVC policies and service requests, you must first define the
service-related elements, such as target devices, VPNs, and network links. Normally, you create these
elements once.
This chapter contains the basic steps to set up the Cisco IP Solution Center (ISC) services for an L2VPN
services. It contains the following sections:
Note
•
Creating Target Devices and Assigning Roles (N-PE or U-PE), page 2-1
•
Configuring Device Settings to Support ISC, page 2-2
•
Defining a Service Provider and Its Regions, page 2-3
•
Defining Customers and Their Sites, page 2-4
•
Defining VPNs, page 2-4
•
Creating Access Domains, page 2-4
•
Creating VLAN Pools, page 2-5
•
Creating a VC ID Pool, page 2-7
•
Creating Named Physical Circuits, page 2-8
•
Creating and Modifying Pseudowire Classes for IOS XR Devices, page 2-10
•
Defining L2VPN Group Names for IOS XR Devices, page 2-14
This chapter presents high-level information on ISC services that are relevant to L2VPN. For more
detailed information on setting up these and other basic ISC services, see the Cisco IP Solution Center
Infrastructure Reference, 6.0.
Creating Target Devices and Assigning Roles (N-PE or U-PE)
Every network element that ISC manages must be defined as a device in the system. An element is any
device from which ISC can collect information. In most cases, devices are Cisco IOS routers that
function as N-PE, U-PE, or P. For detailed steps to create devices, see the Cisco IP Solution Center
Infrastructure Reference, 6.0.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-1
Chapter 2
Setting Up the ISC Services
Configuring Device Settings to Support ISC
Configuring Device Settings to Support ISC
Two device settings must be configured to support the use of ISC in the network:
Note
•
Switches in the network must be operating in VTP transparent mode.
•
Loopback addresses must be set on N-PE devices.
These are the two minimum device settings required for ISC to function properly in the network. You
must, of course, perform other device configuration steps for the proper functioning of the devices in the
network.
Configuring Switches in VTP Transparent Mode
For security reasons, ISC requires VTPs to be configured in transparent mode on all the switches
involved in ERS or EWS services before provisioning L2VPN service requests. To set the VTP mode,
enter the following Cisco IOS commands:
Switch# configure terminal
Switch(config)# vtp mode transparent
Enter the following Cisco IOS command to verify that the VTP mode has changed to transparent:
Switch# Show vtp status
Setting the Loopback Addresses on N-PE Devices
The loopback address for the N-PE has to be properly configured for an Any Transport over MPLS
(AToMPLS) connection. The IP address specified in the loopback interface must be reachable from the
remote pairing PE. The label distribution protocol (LDP) tunnels are established between the two
loopback interfaces of the PE pair. You set the PE loopback address in the Edit PE device window.
Access the Edit PE device window in ISC by doing the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager.
Step 2
Choose PE Devices in the Selection window.
Step 3
Choose a specific device and click the Edit button.
To prevent a wrong loopback address being entered into the system, the loopback IP address field on the
GUI is read-only. You choose the loopback address with the help of a separate pop-up window, which
you access by clicking the Select button. This ensures that you choose only a valid loopback address
defined on the device.
To further narrow the search, you can check the LDPTermination Only check box and click the Select
button. This limits the list to the LDP-terminating loopback interface(s).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-2
OL-21636-01
Chapter 2
Setting Up the ISC Services
Defining a Service Provider and Its Regions
Setting Up Devices for IOS XR Support
L2VPN in ISC 6.0 supports devices running Cisco’s IOS XR software. IOS XR, a new member of the
Cisco IOS family, is a unique self-healing and self-defending operating system designed for always-on
operation while scaling system capacity up to 92Tbps. In L2VPN, IOS XR is only supported on Cisco
XR12000 and CRS-1 series routers functioning as network provider edge (N-PE) devices.
In L2VPN, the following e-line services are supported for IOS XR:
•
Point-to-point ERS with or without a CE.
•
Point-to-point EWS with or without a CE.
The following L2VPN features are not supported for IOS XR:
•
Standard UNI port on an N-PE running IOS XR. (The attribute Standard UNI Port in the Link
Attributes window is disabled when the UNI is on an N-PE device running IOS XR.)
•
SVI interfaces on N-PEs running IOS XR. (The attribute N-PE Pseudo-wire On SVI in the Link
Attributes window is disabled for IOS XR devices.)
•
Pseudowire tunnel selection. (The attribute PW Tunnel Selection in the Link Attributes window is
disabled for IOS XR devices.)
•
EWS UNI (dot1q tunnel or Q-in-Q) on an N-PE running IOS XR.
•
Frame Relay/ATM and VPLS services.
To enable IOS XR support in L2VPN, perform the following steps.
Step 1
Set the DCPL property Provisioning\Service\l2vpn\platform\CISCO_ROUTER\IosXRConfigType to
XML.
Possible values are CLI, CLI_XML, and XML (the default).
Step 2
Create the device in ISC as an IOS XR device, as follows:
a.
Create the Cisco device by choosing Service Inventory > Inventory and Connection Manager >
Devices > Create. The Create Cisco Device window appears.
b.
Set the OS attribute, located under Device and Configuration Access Information, to IOS_XR.
Note
Step 3
For additional information on setting DCPL properties and creating Cisco devices, see the Cisco
IP Solution Center Infrastructure Reference, 6.0.
Create and deploy L2VPN service requests, following the procedures in this guide.
Sample configlets for IOS XR devices are provided in Appendix A, “Sample Configlets”.
Defining a Service Provider and Its Regions
You must define the service provider administrative domain before provisioning L2VPN. The provider
administrative domain is the administrative domain of an ISP with one BGP autonomous system (AS)
number. The network owned by the provider administrative domain is called the backbone network. If
an ISP has two AS numbers, you must define it as two provider administrative domains. Each provider
administrative domain can own many region objects.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-3
Chapter 2
Setting Up the ISC Services
Defining Customers and Their Sites
For detailed steps to define the provider administrative domain, see the Cisco IP Solution Center
Infrastructure Reference, 6.0.
Defining Customers and Their Sites
You must define customers and their sites before provisioning L2VPN. A customer is a requestor of a
VPN service from an ISP. Each customer can own many customer sites. Each customer site belongs to
one and only one Customer and can own many CPEs. For detailed steps to create customers, see the
Cisco IP Solution Center Infrastructure Reference, 6.0.
Defining VPNs
You must define VPNs before provisioning L2VPN or VPLS. In L2VPN, one VPN can be shared by
different service types. In VPLS, one VPN is required for each VPLS instance.
To create a VPN, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager.
Step 2
Click VPNs in the left column.
The VPNs window appears.
For detailed steps to create VPNs, see the Cisco IP Solution Center Infrastructure Reference, 6.0.
Note
The VPN in L2VPN is only a name used to group all the L2VPN links. It has no intrinsic meaning as it
does for MPLS VPN.
Creating Access Domains
For L2VPN and VPLS, you create an Access Domain if you provision an Ethernet-based service and
want ISC to automatically assign a VLAN for the link from the VLAN pool.
For each Layer 2 access domain, you need a corresponding Access Domain object in ISC. During
creation, you select all the N-PE devices that are associated with this domain. Later, one VLAN pool can
be created for an Access Domain. This is how N-PEs are automatically assigned a VLAN.
Before you begin, be sure that you:
•
Know the name of the access domain that you want to create.
•
Have created a service provider to associate with the new access domain.
•
Have created a provider region associated with your provider and PE devices.
•
Have created PE devices to associate with the new access domain.
•
Know the starting value and size of each VLAN to associate with the new access domain.
•
Know which VLAN will serve as the management VLAN.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-4
OL-21636-01
Chapter 2
Setting Up the ISC Services
Creating VLAN Pools
To create an Access Domain, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager.
Step 2
Click Access Domains in the left column.
The Access Domains window appears.
The Access Domains window contains the following:
•
Access Domain Name—Lists the names of access domains. The first character must be a letter. The
name can contain letters, numbers, and these punctuation characters: period, underscore, and dash.
Limit: 80 characters. You can sort the list by access domain name.
•
Provider Name—Lists the names of providers. Must begin with a letter. Can contain letters,
numbers, and these punctuation characters: period, underscore, and dash. Limited to 80 characters.
You can sort the list by provider name.
•
From the Access Domains window, you can create, edit, or delete access domains using the
following buttons:
– Create—Click to create new access domain. Enabled only if you do not select an access
domain.
– Edit—Click to edit the selected access domain (select by checking the corresponding box).
Enabled only if you select a a single access domain.
– Delete—Click to delete the selected access domain (select by checking the corresponding box).
Enabled only if you select one or more access domains.
Creating VLAN Pools
For L2VPN and VPLS, you create a VLAN pool so that ISC can assign a VLAN to the links. VLAN ID
pools are defined with a starting value and a size of the VLAN pool. A VLAN pool can be attached to
an access domain. During the deployment of an Ethernet service, VLAN IDs can be autoallocated from
the access domain’s pre-existing VLAN pools. When you deploy a new service, ISC changes the status
of the VLAN pool from Available to Allocated. Autoallocation gives the service provider tighter control
of VLAN ID allocation.
You can also allocate VLAN IDs manually.
Note
When you are setting a manual VLAN ID on an ISC service, ISC warns you if the VLAN ID is outside
the valid range of the defined VLAN pool. If so, ISC does not include the manually defined VLAN ID
in the VLAN pool. We recommend that you preset the range of the VLAN pool to include the range of
any VLAN IDs that you manually assign.
Create one VLAN pool per access domain. Within that VLAN pool, you can define multiple ranges.
Before you begin, be sure that you:
•
Know each VLAN pool start number.
•
Know each VLAN pool size.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-5
Chapter 2
Setting Up the ISC Services
Creating VLAN Pools
•
Have created an access domain for the VLAN pool. See Creating Access Domains, page 2-4.
•
Know the name of the access domain to which each VLAN pool will be allocated.
To have ISC automatically assign a VLAN to the links, perform the following steps.
Step 1
Choose Service Inventory.
Step 2
Choose Inventory and Connection Manager.
Step 3
Choose Resource Pools.
The Resource Pools window appears.
Step 4
Choose VLAN from the drop-down Pool Type list.
Step 5
Click Create.
The Create VLAN Pool window appears.
Step 6
Enter a VLAN Pool Start number.
Step 7
Enter a VLAN Pool Size number.
Step 8
If the correct access domain is not showing in the Access Domain field, click Select to the right of
Access Domain field.
The Access Domain for New VLAN Pool dialog box appears.
If the correct access domain is showing, continue with Step 9.
Step 9
a.
Choose an Access Domain Name by clicking the button in the Select column to the left of that
Access Domain.
b.
Click Select. The updated Create VLAN Pool window appears.
Click Save.
The updated VLAN Resource Pools window appears.
Note
The pool name is created automatically, using a combination of the provider name and the access domain
name.
Note
The Status field reads “Allocated” if you already filled in the Reserved VLANs information when you
created the access domain. If you did not fill in the Reserved VLANs information when you created the
access domain, the Status field reads “Available.” To allocate a VLAN pool, you must fill in the
corresponding VLAN information by editing the access domain. (See Creating Access Domains,
page 2-4.) The VLAN pool status automatically sets to “Allocated” on the Resource Pools window when
you save your work.
Step 10
Repeat this procedure for each range you want to define within the VLAN.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-6
OL-21636-01
Chapter 2
Setting Up the ISC Services
Creating a VC ID Pool
Creating a VC ID Pool
VC ID pools are defined with a starting value and a size of the VC ID pool. A given VC ID pool is not
attached to any inventory object (a provider or customer). During deployment of an L2VPN or VPLS
service, the VC ID can be autoallocated from the same VC ID pool or you can set it manually.
Note
When you are setting a manual VC ID on an ISC service, ISC warns you if the VC ID is outside the valid
range of the defined VC ID pool. If so, ISC does not include the manually defined VC ID in the VC ID
pool. We recommend that you preset the range of the VC ID pool to include the range of any VC IDs
that you manually assign.
Create one VC ID pool per network.
In a VPLS instance, all N-PE routers use the same VC ID for establishing emulated Virtual Circuits
(VCs). The VC-ID is also called the VPN ID in the context of the VPLS VPN. (Multiple attachment
circuits must be joined by the provider core in a VPLS instance. The provider core must simulate a
virtual bridge that connects the multiple attachment circuits. To simulate this virtual bridge, all N-PE
routers participating in a VPLS instance form emulated VCs among them.)
Note
VC ID is a 32-bit unique identifier that identifies a circuit/port.
Before you begin, be sure that you have the following information for each VC ID pool you must create:
•
The VC Pool start number
•
The VC Pool size
Perform the following steps for all L2VPN and VPLS services.
Step 1
Choose Service Inventory.
Step 2
Choose Inventory and Connection Manager.
Choose Resource Pools.
The Resource Pools window appears.
Step 3
Choose VC ID from the drop-down Pool Type list.
Because this pool is a global pool, it is not associated with any other object.
Step 4
Click Create.
The Create VC ID Pool window appears.
Step 5
Enter a VC pool start number.
Step 6
Enter a VC pool size number.
Step 7
Click Save.
The updated VC ID Resource Pools window appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-7
Chapter 2
Setting Up the ISC Services
Creating Named Physical Circuits
Creating Named Physical Circuits
Before creating an L2VPN or VPLS service request, you must predefine the physical links between CEs
and PEs. The Named Physical Circuit (NPC) represents a link going through a group of physical ports.
Thus, more than one logical link can be provisioned on the same NPC; therefore, the NPC is defined
once but used during several L2VPN or VPLS service request creations.
There are two ways to create the NPC links:
•
Through an NPC GUI editor. For details on how to do this, see Creating NPCs Through an NPC GUI
Editor, page 2-8.
•
Through the autodiscovery process. For details on how to do this, see Creating NPC Links Through
the Autodiscovery Process, page 2-10.
An NPC definition must observe the following creation rules:
•
An NPC must begin with a CE or an up-link of the device where UNI resides or a Ring.
•
An NPC must end with an N-PE or a ring that ends in an N-PE.
If you are inserting NPC information for a link between a CE and UNI, you enter the information as:
•
Source Device is the CE device.
•
Source Interface is the CE port connecting to UNI.
•
Destination Device is the UNI box.
•
Destination interface is the UNI port.
If you are inserting NPC information for a CE not present case, you enter the information as:
•
Source Device is the UNI box.
•
Source Interface is the UP-LINK port, not the UNI port, on the UNI box connecting to the N-PE or
another U-PE or PE-AGG.
•
Destination Device is the U-PE, PE-AGG, or N-PE.
•
Destination Interface is the DOWN-LINK port connecting to the N-PE or another U-PE or PE-AGG.
If you have a single N-PE and no CE (no U-PE and no CE), you do not have to create an NPC since there
is no physical link that needs to be presented.
If an NPC involves two or more links (three or more devices), for example, it connects ence11, enpe1,
and enpe12, you can construct this NPC as follows:
•
Build the link that connects two ends: mlce1 and mlpe4.
•
Insert a device (enpe12) to the link you just made.
•
Click Insert Device to insert the device.
Creating NPCs Through an NPC GUI Editor
To create NPCs through the NPC GUI editor, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Named Physical Circuits.
The Named Physical Circuits window appears.
To create a new NPC, you choose a CE as the beginning of the link and a N-PE as the end. If more than
two devices are in a link, you can add or insert more devices (or a ring) to the NPC.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-8
OL-21636-01
Chapter 2
Setting Up the ISC Services
Creating Named Physical Circuits
Note
The new device or ring added is always placed after the device selected, while a new device or ring
inserted is placed before the device selected.
Each line on the Point-to-Point Editor represents a physical link. Each physical link has five attributes:
Note
•
Source Device
•
Source Interface
•
Destination Device (must be an N-PE)
•
Destination Interface
•
Ring
Before adding or inserting a ring in an NPC, you must create a ring and save it in the repository. To obtain
information on creating NPC rings, see the Cisco IP Solution Center Infrastructure Reference, 6.0.
Source Device is the beginning of the link and Destination Device is the end of the link.
Step 2
Click Create.
The Create a Named Physical Circuit window appears.
Step 3
Click Add Device.
The Select a Device window appears.
Step 4
Choose a CE as the beginning of the link.
Step 5
Click Select.
The device appears in the Create a Named Physical Circuit window.
Step 6
To insert another device or a ring, click Insert Device or Insert Ring.
To add another device or ring to the NPC, click Add Device or Add Ring. For this example, click Add
Device to add the N-PE.
Step 7
Choose a PE as the destination device.
Step 8
Click Select.
The device appears.
Step 9
In the Outgoing Interface column, click Select outgoing interface.
A list of interfaces defined for the device appears.
Step 10
Choose an interface from the list and click Select.
Step 11
Click Save.
The Named Physical Circuits window now displays the NPC that you created.
Creating a Ring-Only NPC
To create an NPC that contains only a ring without specifying a CE, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Named Physical Circuits.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-9
Chapter 2
Setting Up the ISC Services
Creating and Modifying Pseudowire Classes for IOS XR Devices
Step 2
Click Create.
The Create a Named Physical Circuit window appears.
Step 3
Click Add Ring.
The Select NPC Ring window appears.
Step 4
Choose a ring and click Select. The ring appears.
Step 5
Click the Select device link to select the beginning of the ring.
A window appears showing a list of devices.
Step 6
Choose the device that is the beginning of the ring and click Select.
Step 7
Click the Select device link to choose the end of the ring.
Step 8
Choose the device that is the end of the ring and click Select.
Note
The device that is the end of the ring in a ring-only NPC must be an N-PE.
Step 9
The Create a Named Physical Circuit window appears showing the Ring-Only NPC.
Step 10
Click Save to save the NPC to the repository.
Terminating an Access Ring on Two N-PEs
ISC supports device-level redundancy in the service topology to provide a failover in case one access
link should drop. This is accomplished through a special use of an NPC ring that allows an access link
to terminate at two different N-PE devices. The N-PEs in the ring are connected by a logical link using
loopback interfaces on the N-PEs. The redundant link starts from a U-PE device and may, optionally,
include PE-AGG devices.
For details on how to implement this in ISC, see Appendix D, “Terminating an Access Ring on Two
N-PEs.”
Creating NPC Links Through the Autodiscovery Process
With autodiscovery, the existing connectivity of network devices can be automatically retrieved and
stored in the ISC database. NPCs are further abstracted from the discovered connectivity.
For detailed steps to create NPCs using autodiscovery, see the Cisco IP Solution Center Infrastructure
Reference, 6.0.
Creating and Modifying Pseudowire Classes for IOS XR Devices
The pseudowire class feature provides you with the capability to configure various attributes associated
with a pseudowire that is deployed as part of an L2VPN service request on IOS XR-capable devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-10
OL-21636-01
Chapter 2
Setting Up the ISC Services
Creating and Modifying Pseudowire Classes for IOS XR Devices
Note
The pseudowire class feature is supported for IOS XR 3.6.1 and higher.
The pseudowire class feature supports configuration of the encapsulation, transport mode, fallback
options, and selection of a traffic engineering tunnel down which the pseudowire can be directed. For
tunnel selection, you can select the tunnel using the ISC Traffic Engineering Management (TEM)
application, if it is being used. Otherwise, you can specify the identifier of a tunnel that is already
provisioned within the network. For IOS XR-capable devices, the pseudowire class is a separately
defined object in the ISC repository, which can be attached to an L2VPN service policy or service
request. The pseudowire class feature is only available for use in L2VPN ERS, EWS and ATM policies
and service requests.
This section describes how to create and modify pseudowire classes. For information on how the
pseudowire class is associated to a L2VPN policy and used within a service request, see Chapter 7,
“Creating an L2VPN Policy” and Chapter 8, “Managing an L2VPN Service Request.”
Creating a Pseudowire Class
To create a pseudowire class, perform the following steps.
Step 1
Navigate to Service Inventory > Inventory and Connection Manager.
Step 2
Click the PseudoWireClass icon.
The Pseudowire Classes window appears.
Step 3
Click the Create button.
The Create PseudowireClass window appears, as shown in Figure 2-1.
Figure 2-1
Step 4
Create PseudoWireClass Window
In the Name field, enter a valid PseudoWireClass name.
The pseudowire class name is used for provisioning pw-class commands on the XR device. The name
should not exceed 32 characters and should not contain spaces.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-11
Chapter 2
Setting Up the ISC Services
Creating and Modifying Pseudowire Classes for IOS XR Devices
Step 5
In the Description field, enter a meaningful description of less than 128 characters.
This field is optional.
Step 6
Choose the MPLS encapsulation type from the Encapsulation drop-down list.
Note
Step 7
Choose the transport mode from the TransportMode drop-down list. The choices are:
•
Ethernet
•
Vlan
•
NONE (default)
Note
Step 8
Currently, the only encapsulation type supported is MPLS.
If you want to set the TransportMode to Vlan, we recommend you do this via a pseudowire class,
if supported by the version of IOS XR being used. If pseudowire class is not supported in a
particular version of IOS XR, then you must set the TransportMode using a Dynamic Component
Properties Library (DCPL) property, as explained in the section Configuring the Transport Mode
When Pseudowire Classes are Not Supported, page 2-13.
Enter a Tunnel ID of a TE tunnel that has already been provisioned by ISC or that has been manually
provisioned on the device.
This value is optional. You can also select a TE tunnel that has already been provisioned by ISC, as
covered in the next step.
Step 9
Click Select TE Tunnel if you want to select a TE tunnel that has been previously provisioned by ISC.
The Select TE Tunnel pop-up window appears. Choose a TE tunnel and click Select. This populates the
TE Tunnel field with the ID of the selected TE tunnel.
Note
Step 10
After a TE tunnel is associated to a pseudowire class or provisioned in a service request, you will
receive an error message if you try to delete the TE tunnel using the Traffic Engineering
Management (TEM) application. TE tunnels associated with a pseudowire class or service
request cannot be deleted.
Check the Disable Fallback check box to disable the fallback option for the pseudowire tunnel.
Choose this option based on your version of IOS XR. It is required for IOS XR 3.6.1 and optional for
IOS XR 3.7 and above.
Modifying a Pseudowire Class Object
This section describes how to modify (edit) an existing pseudowire class and how the editing operation
might impact L2VPN service requests.
To modify a pseudowire class, perform the following steps.
Step 1
Navigate to Service Inventory > Inventory and Connection Manager > PseudoWireClass.
The PseudoWire Classes window appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-12
OL-21636-01
Chapter 2
Setting Up the ISC Services
Creating and Modifying Pseudowire Classes for IOS XR Devices
Step 2
Select the pseudowire class object you want to modify, and click Edit.
The Edit PseudoWire Class window appears.
Step 3
Make the desired changes and click Save.
Note
The Name field is not editable if the pseudowire class is associated with any service requests.
If the pseudowire class being modified is associated with any L2VPN service requests, the Affected Jobs
window appears, which displays a list of affected service requests, as shown in Figure 2-2.
Note
A list of affected service requests only appears if the Transport Mode, Tunnel ID, or Disable
Fallback values are changed in the pseudowire class being modified.
Figure 2-2
Step 4
Affected Jobs
Click Save to update service requests associated with the modified pseudowire class.
The impacted service requests are moved to the Requested state.
Step 5
Click Save and Deploy to update and deploy service requests associated with the modified pseudowire
class.
Deployment tasks are created for the impacted service requests that were previously in the Deployed
state.
Step 6
Click Cancel to discard changes made to the modified pseudowire class.
In this case, no change of state occurs for any service requests associated with the pseudowire class.
Configuring the Transport Mode When Pseudowire Classes are Not Supported
This section describes how to configure the pseudowire transport mode to be of type Vlan for versions
of IOS XR that do not support pseudowire classes. This is done through setting a Dynamic Component
Properties Library (DCPL) property. See the usage notes following the steps for additional information.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
2-13
Chapter 2
Setting Up the ISC Services
Defining L2VPN Group Names for IOS XR Devices
Perform the following steps.
Step 1
In ISC, navigate to Administration > Control Center > Hosts.
Step 2
Check a check box for a specific host and click the Config button.
Step 3
Navigate to the DCPL property Services\Common\pseudoWireVlanMode.
Step 4
Set the property to true.
Step 5
Click Set Property.
ISC then generates VLAN transport mode configuration for the pseudowire.
Usage notes:
•
To set the transport mode to Vlan, it is recommended that you do this via a pseudowire class, if
supported by the version of IOS XR being used. If the pseudowire class feature is not supported,
then the transport mode must be set using a DCPL property, as explained in the steps of this section
•
The DCPL property pseudoWireVlanMode only sets the default value for PseudoWireClass
TransportMode as Vlan if the DCPL property is set to true. Users can always over ride it.
•
The DCPL property pseudoWireVlanMode acts in a dual way:
– It sets a default value for PseudoWireClass TransportMode to Vlan.
– In the absence of a pseudowire class, it generates a deprecated command transport-mode vlan.
The transport-mode vlan command is a deprecated command in IOS XR 3.6 and later. Thus,
when a pseudowire class is selected for an IOS XR device and the DCPL property is also set to
true, the transport-mode vlan command is not generated. Pseudowire class and the
transport-mode vlan command do not co-exist. If a pseudowire class is present, it takes
precedence over the deprecated transport-mode vlan command.
•
The value of the DCPL property pseudoWireVlanMode should not be changed during the life of a
service request.
Defining L2VPN Group Names for IOS XR Devices
This section describes how to specify the available L2VPN group names for policies and service requests
for IOS XR devices. The choices appear in a drop-down list of the L2VPN Group Name attribute in
policies and service requests. The name chosen is used for provisioning the L2VPN group name on IOS
XR devices. The choices are defined through setting a Dynamic Component Properties Library (DCPL)
property.
Perform the following steps.
Step 1
In ISC, navigate to Administration > Control Center > Hosts.
Step 2
Check a check box for a specific host and click the Config button.
Step 3
Navigate to the DCPL property Services\Common\l2vpnGroupNameOptions.
Step 4
Enter a comma-separated list of L2VPN group names in the New Value field.
Step 5
Click Set Property.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
2-14
OL-21636-01
CH A P T E R
3
Creating a FlexUNI/EVC Ethernet Policy
This chapter contains an overview of FlexUNI/EVC support in ISC, as well as the basic steps to create
a FlexUNI/EVC Ethernet policy. It contains the following sections:
•
Overview of FlexUNI/EVC Support in ISC, page 3-1
•
Defining the FlexUNI/EVC Ethernet Policy, page 3-6
•
Setting the Service Options, page 3-8
•
Setting the FlexUNI Attributes, page 3-10
•
Setting the Interface Attributes, page 3-16
•
Enabling Template Association, page 3-23
For information on creating FlexUNI/EVC Ethernet service requests, see Chapter 4, “Managing a
FlexUNI/EVC Ethernet Service Request.”
Note
For Ethernet (E-Line and E-LAN) services, use of the FlexUNI/EVC policy and service request is
recommended. If you are provisioning services using the FlexUNI/EVC syntax, or plan to do so in the
future, use the FlexUNI/EVC service. Existing services that have been provisioned using the L2VPN and
VPLS service policy types are still supported and can be maintained with those service types. For ATM
and FRoMPLS services, use the L2VPN service policy, as before.
Overview of FlexUNI/EVC Support in ISC
Flexible user network interface (FlexUNI) is a generic approach for creating Ethernet services in ISC. It
can, if supported by the hardware, be used for all Ethernet provisioning. (For information on what
platforms support FlexUNI/EVC see Platform Support for FlexUNI/EVC in ISC 6.0, page 3-3.) The
FlexUNI/EVC policy is flexible and generic and allows for service designers to provide greater service
offerings than available through traditional ISC L2VPN and VPLS services.
Certain line cards have interfaces that support the Cisco IOS Ethernet Virtual Circuit (EVC) syntax.
These interfaces can be configured with either EVC infrastructure features or with switch-port
command-line interface commands (Class). FlexUNI optionally supports the EVC CLI
syntax/infrastructure. For this reason, the FlexUNI policies and service requests are referred to by the
umbrella term “FlexUNI/EVC.” However, it is important to note that FlexUNI/EVC policies and service
request are not tied to the new EVC syntax. Service endpoints can use non-EVC syntax also.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-1
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Overview of FlexUNI/EVC Support in ISC
Services leveraging the FlexUNI/EVC infrastructure are varied in nature, and there is not always a clear
delineation between different services. This is because FlexUNI/EVC provides great flexibility in the
way these services can be delivered. This can make it challenging to define the services. For example, a
traditional ERS could be delivered in several ways by variations of the Class on the platform.
The FlexUNI/EVC policy and associated service request offer a generic and flexible service construct to
support device capabilities. This policy is flexible enough to cater to different service offerings using the
EVC architecture. It allows service designers to utilize most of the EVC features in a flexible manner,
to match the hardware and platform capabilities.
The FlexUNI/EVC policy can be used to create only a FlexUNI/EVC service request and not any other
existing ISC service request types, such as L2VPN, VPLS, and so on. Likewise, a FlexUNI/EVC service
request can be created using only a FlexUNI/EVC policy and not any other existing ISC policies.
The FlexUNI/EVC infrastructure provides several benefits to Carrier Ethernet (CE) deployments,
including:
•
Flexible frame matching.
•
Flexible VLAN tag manipulation and/or translation.
•
Multiple services on the same port.
•
Flexible service mapping.
•
VLAN scaling and locally significant VLANs.
FlexUNI/EVC supports a variety of network configurations, such as the following:
•
Provisioning of Ethernet access as a EVC-capable EWS interface on the N-PE.
•
Interconnecting Ethernet accesses terminating on a single Cisco 7600 N-PE on one or multiple ports
in a bridge domain.
•
Interconnecting Ethernet accesses terminating on multiple Cisco 7600 N-PEs in a VPLS service.
•
FlexUNI/EVC service support on Cisco ASR 9000 Series Routers running IOS XR.
•
Services that combine the existing services with the Ethernet access, including the ERS/EWS
interworking service.
•
Provisioning of E-Line services, in which one or both N-PE interfaces are FlexUNI.
FlexUNI/EVC Features
This section summarizes the features supported by the FlexUNI/EVC policy and service request in ISC:
•
Choice of topology:
– Customer edge device (CE) directly connected.
– CE connected through Ethernet access devices.
•
Choice of platforms:
– FlexUNI/EVC on all N-PEs.
– FlexUNI/EVC on none of the N-PEs.
– Mix of FlexUNI/EVC and the old infrastructure. This allows both the old and new platforms to
co-exist, in order to ensure continued support for deployed platforms.
•
Choice of connectivity across the MPLS core (with or without bridge-domain):
– Pseudo wires
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-2
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Overview of FlexUNI/EVC Support in ISC
– VPLS
– Local (local connects)
•
Flexible VLAN handling mechanism that deals with up to two levels of VLAN tags:
– VLAN matching for service classification. This provides the ability to match both outer and
inner VLAN tags, or the ability to match a range of inner VLAN tags.
– VLAN manipulations, such as pop outer tag, pop inner tag, push outer tag, push inner tag, and
VLAN translations (1:1, 2:1, 1:2, 2:2).
•
Flexible forwarding options:
– Configure a pseudowire on the MPLS core directly under a service instance (for E-Line only).
– Configure a pseudowire on the MPLS core under a switch virtual interface (SVI) by associating
it to a bridge domain.
The appropriate VLAN manipulations are applicable to pseudowire in both cases.
Note
– Associate traffic from different interfaces and/or VLANs onto a single bridge domain, with
appropriate VLAN manipulations for VPLS.
– Associate traffic from different interfaces and/or VLANs onto a single bridge domain with
appropriate VLAN manipulations for local connects.
Platform Support for FlexUNI/EVC in ISC 6.0
FlexUNI/EVC services are supported on both IOS and IOS XR platforms, as detailed in the following
sections.
IOS Platform Support
The following IOS platforms are supported for the FlexUNI/EVC service:
•
IOS 12.2(33)SRB and SRC
•
ES20 line cards (2x10GE and 20x1GE)
•
Shared Port Adaptor (SPA) Interface Processor-400 (SIP-400) line cards, version 2.0 (2x1GE and
5x1GE)
The interfaces on the ES20 and SIP-400 line cards support the IOS EVC syntax.
Two example platform scenarios are covered in the next sections. Note that the UNI characteristics and
the FlexUNI capabilities of the N-PE are not inter-dependent.
Example 1
FlexUNI/EVC service requests allow operators to add links with either a EVC-capable interface and/or
the nonEVC-capable interface on the N-PE. For example, an operator can add three links to a
FlexUNI/EVC service request (with VPLS connectivity) with the following configurations:
•
Link one has a Cisco 67xx interface and an IOS 12.2 (33)SRB image on a Cisco 7600 N-PE.
•
Link two has a Cisco 67xx interface and an IOS 12.2 (33)SRB image on a Cisco 7600 N-PE.
•
Link three has an ES20-based interface and an IOS 12.2 (33)SRB image on a Cisco 7600 N-PE.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-3
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Overview of FlexUNI/EVC Support in ISC
Example 2
As far as Layer 2 access nodes are concerned, configurations on the UNI/NNI of a U-PE and/or PE-AGG
are not influenced by the FlexUNI/EVC capability on the N-PE. However, if a selected named physical
circuit (NPC) with N-PE interface is configured with FlexUNI/EVC, it cannot be provisioned for
traditional configuration. An error will be generated while saving the service request.
On the other hand, if a selected NPC with N-PE interface is configured without FlexUNI, it cannot be
provisioned for FlexUNI configuration. An error will be generated while saving the service request.
For example, if for link one of a FlexUNI/EVC service request, if the encapsulation is selected as dot1Q,
the interface can share other L2 ERS/VPLS ERMS UNIs on the same U-PE/PE-AGG.
If the N-PE interface that is part of the NPC being picked is already configured with non-FlexUNI/EVC
features (using an existing L2VPN or VPLS service request), you cannot configure FlexUNI/EVC on it.
Note
If “Dot1Q Tunnel” is selected as the encapsulation type, the port cannot be shared with other services.
IOS XR Platform Support
FlexUNI/EVC services are supported on Cisco ASR 9000 Series Routers running IOS XR 3.7.3 and
3.9.0.
The following FlexUNI/EVC features are supported on IOS XR platforms:
•
E-line connections. If an ASR 9000 is added on a direct link, only DOT1Q encapsulation is
supported for E-Line services. When using L2 access nodes with NPCs, all supported encapsulations
are available.
•
E-LAN connections.
•
Flexible frame matching.
•
Flexible VLAN tag manipulation/translation.
•
VLAN scaling and locally significant VLANs.
•
The ability to create L2 and L3 services under the same physical interface, restricted only to
subinterface.
•
All the Layer 2 ports on Cisco ASR 9000 devices are trunk ports, hence only trunk port-based
configuration is supported.
The following FlexUNI/EVC services are not supported on IOS XR platforms:
Note
•
The N-PE Pseudo-wire on SVI attribute is not supported. SVI interfaces are not available on the
devices, which restricts support for Standard UNI and Port Security configuration when the UNI is
configured on an N-PE.
•
xconnect commands are not directly supported under interface configuration. Support for these
commands has been moved to different a hierarchy in IOS XR.
•
When the UNI is configured on an N-PE device, EWS service is not supported. Since the Cisco
ASR 9000 device is a router, all the Layer 2 ports are default trunk. There is no option for
configuring access ports, which restricts support for access port-based services.
Unless otherwise noted, all of the FlexUNI/EVC policy and service request features documented in this
guide are applicable for both IOS and IOS XR platforms.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-4
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Overview of FlexUNI/EVC Support in ISC
Device Roles with FlexUNI/EVC
Presently, ISC has U-PE, PE-AGG and N-PE devices. The basic PE device role association of ISC
continues for FlexUNI/EVC policy and service requests. In this release of ISC, there are no changes
made to the PE role assignment. A device having FlexUNI/EVC capabilities will not call for a change
in the existing role assignment in ISC. However, FlexUNI/EVC capabilities in ISC are supported only
for interfaces on N-PE and not on PE-AGG or U-PE devices.
Note
ISC does not support customer edge devices (CEs) for FlexUNI/EVC. If the access port contains any
DSLAMS, non-Cisco Ethernet devices and/or other Cisco devices that are not supported by ISC, such
nodes and beyond are not in the scope of ISC. In such cases, from the ISC perspective, the interface on
the first ISC-managed device is the UNI.
Topology Overview for FlexUNI/EVC
This section provides examples of various topologies supported with FlexUNI/EVC. As mentioned in
the note at the end of section Device Roles with FlexUNI/EVC, page 3-5, ISC does not support customer
edge devices (CEs) with FlexUNI/EVC. References to the term “CE” in the following topology
variations (such as “CE directly connected” and so on) is only to indicate how the customer or third-party
devices connect to the N-PE. For all the cases involving FlexUNI/EVC, the CE is not supported in ISC.
Also, any provider device that is not supported by ISC, and which is used in the access circuit, marks the
boundary for the scope of ISC, beyond which no devices (that is, towards the CE, and including the
unsupported node) is managed by ISC.
CE Directly Connected and FlexUNI
With this combination, the UNI is the interface on a supported line card, with EVC capability configured.
ISC does not configure ISC’s standard UNI functionality (for example, port-security, storm control, and
Layer 2 Protocol Tunneling). This is because of lack of command support on the FlexUNI/EVC-capable
hardware. Operators can use templates to configure relevant platform supported parameters to realize
any of these features not provided by ISC. ISC configures only the service instance with VLAN
manipulations and pseudowire, VPLS, or local-connect on the UNI. NPCs are not needed while creating
such links because NPCs are only required when there are access nodes between the N-PE and CE. Other
intermediate Ethernet access nodes are not involved in this topology.
CE Directly Connected and No FlexUNI
This is similar to the UNI on N-PE case in ISC. The FlexUNI/EVC service request can be used to create
such links with older Cisco 7600 platforms (that is, N-PE interfaces without FlexUNI/EVC capability),
but with plans of adding one or more future links with EVC support. If not, one could use the existing
ERS/EWS/ERMS/EMS functionality in ISC. NPCs are not needed while creating such links because
NPCs are only required when there are access nodes between the N-PE and CE. Other intermediate
Ethernet access nodes are not involved in this topology.
CE Not Directly Connected and FlexUNI
This topology involves the following configurations:
•
UNI on a U-PE or PE-AGG to which the CE is connected.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-5
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Defining the FlexUNI/EVC Ethernet Policy
•
Ethernet U-PE and/or PE-AGGs.
•
N-PE with FlexUNI-capable interface on the CE-facing side.
All service-specific parameters, such as port-security, L2 Protocol Tunneling, storm control, and so on,
are applicable to the UNI (Standard UNI) in such links. The U-PE and/or PE-AGG configurations will
also have no change in CLIs. However, the EVC commands are applicable only on the N-PE (on the
CE-facing interface). NPCs are used while creating such links.
CE Not Directly Connected and No FlexUNI
This link is identical to an attachment circuit in existing ISC implementations. This has a standard UNI
as in existing ISC services. NPCs are used while creating such links.
A Note on Checking of Configurations
ISC attempts to provision all configurations generated by a FlexUNI/EVC service request. ISC does not
perform any prior checks to verify if the CLIs are compatible with the specific devices being
provisioned. This is to ensure flexibility of support for device/platform features, which could change
over time. Hence, it is important for the service designer or operator to carefully create the
FlexUNI/EVC policies and service requests.
Defining the FlexUNI/EVC Ethernet Policy
You must define a FlexUNI/EVC Ethernet policy before you can provision a service. A policy can be
shared by one or more service requests that have similar service requirements.
A policy is a template of most of the parameters needed to define a FlexUNI/EVC service request. After
you define it, a FlexUNI/EVC policy can be used by all the FlexUNI/EVC service requests that share a
common set of characteristics. You create a new FlexUNI/EVC policy whenever you create a new type
of service or a service with different parameters. FlexUNI/EVC policy creation is normally performed
by experienced network engineers.
An Editable check box in for an attribute in the policy gives the network operator the option of making
a field editable. If the value is set to editable, the service request creator can change the value(s) of the
particular policy attribute. If the value is not set to editable, the service request creator cannot change
the attribute.
You can also associate Cisco IP Solution Center (ISC) templates and data files with a service request.
See Appendix B, “Working with Templates and Data Files,” for more about using templates and data
files in service requests.
To define a FlexUNI/EVC Ethernet policy, you start by setting the service type attributes. To do this,
perform the following steps.
Step 1
Choose Service Design > Policies.
The Policies window appears.
Step 2
Click Create.
Step 3
Choose FlexUNI (EVC) Policy.
The EVC Policy Editor - Service Type window appears, as shown in Figure 3-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-6
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Defining the FlexUNI/EVC Ethernet Policy
Figure 3-1
EVC Policy Editor - Service Type
Step 4
Enter a Policy Name for the FlexUNI/EVC policy.
Step 5
Choose the Policy Owner for the FlexUNI/EVC policy.
There are three types of FlexUNI/EVC policy ownership:
•
Customer ownership
•
Provider ownership
•
Global ownership—Any service operator can make use of this policy.
This ownership has relevance when the ISC Role-Based Access Control (RBAC) comes into play. For
example, a FlexUNI/EVC policy that is customer-owned can only be seen by operators who are allowed
to work on this customer-owned policy. Similarly, operators who are allowed to work on a provider’s
network can view, use, and deploy a particular provider-owned policy.
Step 6
Click Select to choose the owner of the FlexUNI/EVC policy.
The policy owner was established when you created customers or providers during ISC setup. If the
ownership is global, the Select function does not appear.
Step 7
Choose the Policy Type.
The choices are:
Note
Step 8
•
ETHERNET
•
ATM-Ethernet Interworking
This chapter describes creating the ETHERNET policy type. For information on using the FlexUNI/EVC
ATM-Ethernet Interworking policy type, see Chapter 5, “Creating a FlexUNI/EVC ATM-Ethernet
Interworking Policy.”
Click Next.
The EVC Policy Editor - Service Options window appears, as show in Figure 3-2.
Step 9
Continue with the steps contained in the next section, Setting the Service Options, page 3-8.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-7
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Service Options
Setting the Service Options
This section describes how to set the service options for the FlexUNI/EVC Ethernet policy, as shown in
Figure 3-2.
Figure 3-2
EVC Policy Editor - Service Options Window
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this FlexUNI/EVC policy can modify the editable parameter
during FlexUNI/EVC service request creation.
To set the FlexUNI/EVC service options, perform the following steps.
Step 1
Check the CE Directly Connected to FlexUNI check box if the CEs are directly connected to the N-PE.
This check box is not checked by default.
Usage notes:
Step 2
•
If the check box is checked, a service request created using this policy can have only directly
connected links. No Ethernet access nodes will be involved.
•
If the check box is unchecked, a service request created using this policy might or might not have
Ethernet access nodes in the links.
•
When a CE is directly connected to the N-PE, NPCs are not applicable to the link while creating
service requests.
•
When a CE is not directly connected to the N-PE, NPCs are used during service request creation, as
per standard ISC behavior. There is no change in NPC implementation to support FlexUNI/EVC
functionality.
Check the All Links Terminate on FlexUNI check box if all links need to be configured with
FlexUNI/EVC features.
This check box is not check by default. Usage notes:
•
If the check box is checked, a service request created using such policy will have all links using the
FlexUNI/EVC feature.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-8
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Service Options
•
If the check box is unchecked, zero or more links can use the FlexUNI/EVC feature. This ensures
that existing platforms can still be used in one or more links while delivering the services. This
allows the possibility of a link with FlexUNI/EVC support being added in the future.
Note
•
Step 3
Note
If the check box is unchecked, in the service request creation process the user must indicate
whether or not the created link is FlexUNI or non-FlexUNI.
If no links are expected to use the FlexUNI/EVC feature even in the future (for example, if the
provider is not planning to upgrade to the EVC infrastructure for the service that is being created),
existing ISC policy types (L2VPN or VPLS) can be used instead of FlexUNI/EVC.
Choose an MPLS Core Connectivity Type from the drop-down list.
The core option supports MPLS only. There is no L2TPv3 support for this service.
The choices are:
•
PSEUDOWIRE—Choose this option to allow connectivity between two N-PEs across the MPLS
core. This option does not limit the service to point-to-point (E-Line). This is because even with the
PSEUDOWIRE option selected, there can still be multiple CEs connected to a bridge domain on one
or both sides of the pseudowire.
•
VPLS—Choose this option to allow connectivity between multiple N-PEs across the MPLS core.
There is no limit on the number of N-PEs across the MPLS core within a service request. However,
many service requests can refer to the same customer-associated VPN.
•
LOCAL—Choose this option for local connect cases in which there is no connectivity required
across the MPLS core.
Local connect supports the following scenarios:
– All interfaces on the N-PE are FlexUNI-capable and using the EVC infrastructure. This is
configured by associating all of the customer traffic on these interfaces to a bridge domain. This
consumes a VLAN ID on the N-PE (equal to the bridge domain ID).
– Some interfaces on the N-PE are FlexUNI-capable, while others are switch-port-based. In such
cases, all of the customer traffic on the interfaces that are configured with the EVC
infrastructure are associated to a bridge domain. The traffic on the non-FlexUNI interfaces (and
all the access nodes/interfaces beyond this N-PE) are configured with the Service Provider
VLAN ID, where the Service Provider VLAN ID is the same as the bridge domain ID for the
EVC-based services.
– Only two interfaces on the N-PE are involved, and both are based on FlexUNI-capable line
cards. In the first case, the operator might choose not to configure the bridge domain option. In
this case, the connect command that is used for the local connects are used, and the global
VLAN is conserved on the device. If the operator chooses to configure with the bridge domain
option, both interfaces are associated to a bridge domain ID, so that additional local links can
be added to the service in future. This consumes a VLAN ID (bridge domain ID) on the N-PE.
Note
Attributes available in subsequent windows of the policy workflow dynamically change based on the
choice made for the MPLS Core Connectivity Type (PSEUDOWIRE, LOCAL, or VPLS). For
completeness, all attributes available for the different core types are documented in the following steps.
Attributes apply to all core types, unless otherwise noted.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-9
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the FlexUNI Attributes
Note
Step 4
Also, some attributes are supported only on IOS or IOS XR platforms. Attributes apply to both
platforms, unless otherwise noted. All platform-specific attributes are visible in the policy workflow
windows. Later, when a service request is created based on the policy (and specific devices are
associated with the service request), platform-specific attributes are filtered from service request
windows, depending on the device type (IOS or IOS XR).
Check the Configure With Bridge Domain check box to determine bridge domain characteristics.
The behavior of the Configure With Bridge-Domain option works in tandem with the choice you selected
in the MPLS Core Connectivity Type option, as follows.
•
PSEUDOWIRE as the MPLS Core Connectivity Type. There are two cases:
A. With FlexUNI:
– If Configure With Bridge Domain is checked, the policy configures pseudowires under SVIs
associated to the bridge domain.
– If Configure With Bridge Domain is unchecked, the policy will configure pseudowires
directly under the service instance. This conserves the global VLAN.
B. Without FlexUNI:
– If Configure With Bridge Domain is checked, the policy configures pseudowires as in L2VPN
services (with SVIs).
– If Configure With Bridge Domain is unchecked, the policy configures pseudowires directly
under subinterfaces.
Only pseudowires can be either configured directly under service instance of the corresponding
FlexUNI-capable interface or under SVIs associated to the bridge domain.
•
LOCAL as the MPLS Core Connectivity Type:
– If Configure With Bridge Domain is checked, the policy allows either point-to-point or
multipoint local connect services.
– If Configure With Bridge Domain is unchecked, ISC allows only point-to-point local connects
without bridge domain.
•
Step 5
VPLS—Configure With Bridge Domain is checked by default and non-editable.
Click Next.
The EVC Policy Editor - FlexUNI Attribute window appears, as shown in Figure 3-3.
Step 6
Continue with the steps contained in the next section, Setting the FlexUNI Attributes, page 3-10.
Setting the FlexUNI Attributes
This section describes how to set the FlexUNI attributes for the FlexUNI/EVC Ethernet policy, as shown
in Figure 3-3.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-10
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the FlexUNI Attributes
Figure 3-3
EVC Policy Editor - FlexUNI Attribute Window
FlexUNI attributes are organized under the following categories:.
•
Service Attributes
•
VLAN Match Criteria
•
VLAN Rewrite Criteria
The following sections describe how to set the options under each category.
Setting the Service Attributes
To set the FlexUNI service attributes, perform the following steps.
Step 1
Check the AutoPick Service Instance ID check box to specify that the service instance ID will be
autogenerated and allocated to the link during service request creation.
If the check box is unchecked, while setting the ISC link attributes during service request creation, ISC
will prompt the operator to specify the service instance ID.
Usage notes:
Step 2
•
The service instance ID represents an Ethernet Flow Point (EFP) on an interface in the EVC
infrastructure. The service instance ID is locally significant to the interface. This ID has to be unique
only at the interface level. The ID must be a value from 1 to 8000.
•
There are no resource pools available in ISC from which to allocate the service instance IDs.
•
It is the responsibility of the operator creating the service request to maintain the uniqueness of the
ID at the interface level.
Check the AutoPick Service Instance Name check box to have ISC autogenerate a service instance
name when you create a service request based on the policy. The autogenerated value is in the following
pattern: CustomerName_ServiceRequestJobID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-11
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the FlexUNI Attributes
If the check box is unchecked, then you can enter a value during service request creation.
Step 3
Check the Enable PseudoWire Redundancy check box to enable pseudowire redundancy (alternative
termination device) under certain conditions.
Usage notes:
Step 4
•
Enable Pseudo Wire Redundancy is only available if the MPLS Core Connectivity Type was set as
PSEUDOWIRE in the Service Options window (see Setting the Service Options, page 3-8).
•
See Appendix D, “Terminating an Access Ring on Two N-PEs” and, specifically, the section Using
N-PE Redundancy in FlexUNI/EVC Service Requests, page D-3, for notes on how this option can
be used.
Check the AutoPick VC ID check box to have ISC autopick the VC ID during service request creation.
If this check box is unchecked, the operator will be prompted to specify a VC ID during service request
creation.
Usage notes:
Step 5
•
This attribute is available only if MPLS Core Connectivity of Type was set as PSEUDOWIRE or
VPLS in the Service Options window (see Setting the Service Options, page 3-8).
•
When AutoPick VC ID is checked, ISC allocates a VC ID for pseudowires from the ISC-managed
VC ID resource pool.
•
If MPLS Core Connectivity of Type is VPLS, ISC allocates the VPLS VPN ID from the
ISC-managed VC ID resource pool.
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID for the
service request during service request creation.
If this check box is unchecked, the operator will be prompted to specify a VLAN ID during service
request creation.
Usage notes:
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain/VLAN ID is picked from the existing ISC VLAN pool. Once the VLAN ID is
assigned in the service request, ISC makes the VLAN ID unavailable for subsequent service
requests.
•
In the case of manual VLAN ID allocation, ISC does not manage the VLAN ID if the ID lies outside
the range of an ISC-managed VLAN pool. In this case, the operator must ensure the uniqueness of
the ID in the Ethernet access domain. If an operator specifies a VLAN ID that is within the range of
an ISC-managed VLAN pool and the VLAN ID is already in use in the access domain, ISC displays
an error message indicating that the VLAN ID is in use.
Note on Access VLAN IDs
An access VLAN ID is of local significance to the FlexUNI-capable ports. It should not be confused with
the global VLANs. This can be visualized as a partitioning of the Ethernet access network beyond the
FlexUNI ports into several subEthernet access domains (one each for a FlexUNI-capable port).
However, all the service interfaces on the Ethernet access nodes beyond the FlexUNI ports will have this
very same VLAN ID for a link. This ID must be manually specified by the operator when setting the link
attributes during service request creation. The operator must ensure the uniqueness of the ID across the
FlexUNI-demarcated Ethernet access domain.
These VLAN IDs are not managed by ISC by means of locally-significant VLAN pools. But once a
VLAN ID is assigned for a link in the service request, ISC makes the VLAN unavailable for subsequent
service requests within the Ethernet access domain demarcated by the FlexUNI. Likewise, if a
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-12
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the FlexUNI Attributes
manually-specified VLAN is already in use in the access domain delimited by the FlexUNI, ISC will
display an error message indicating that the new VLAN ID being specified is already in use on the NPC.
The operator will be prompted to specify a different VLAN ID, which will be provisioned on the L2
access nodes.
Step 6
Check the AutoPick Bridge Group Name check box to have ISC autopick the group name for the
service request during service request creation.
If this check box is unchecked, the operator will be prompted to specify a group name during service
request creation. If the check box is checked, the group name will default to the customer name.
Note
Step 7
This attribute is applicable only for supported IOS XR devices.
Check the AutoPick Bridge Domain Name check box to have ISC autopick the domain name for the
service request during service request creation.
Usage notes:
•
If this check box is unchecked, the operator will be prompted to specify a domain name during
service request creation.
•
If the check box is checked, the domain name will default to the following format:
– For pseudowire and local connect core types: ISC-Job-Job_ID, where Job_ID is the service
request job ID.
– For VPLS core type: ISC-VPN_Name-VPN_ID, where VPN_Name is the name of the VPLS
VPN being used, and VPN_ID is the VPN ID used in the service request.
Note
Step 8
This attribute is applicable only for supported IOS XR devices.
Continue with the steps contained in the next section, Setting the VLAN Matching Criteria Attributes,
page 3-13.
Setting the VLAN Matching Criteria Attributes
Prior to the introduction of the FlexUNI capability, service providers could either deploy
service-multiplexed services (ERS/ERMS or EVPL/EVCS) or service-bundled services on a single port.
Both could not be supported simultaneously due to the limitations in the infrastructure, which only
allowed matching the outer-most VLAN tag.
One of the key benefits of FlexUNI/EVC support in ISC is to provide a flexible means to examine the
VLAN tags (up to two levels) of the incoming frames and associate them to appropriate Ethernet Flow
Points (EFPs). This allows service providers to deploy simultaneously both the service-multiplexed and
service-bundled services on a single port.
To set the FlexUNI VLAN matching criteria attributes, perform the following steps.
Step 1
Check the Both Tags check box to enable service requests created with the policy to match both the inner
and outer VLAN tags of the incoming frames.
If you do not check this check box, service requests created with the policy will match only the outer
VLAN tag of the incoming frames.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-13
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the FlexUNI Attributes
Checking the Both Tags attribute causes the Inner VLAN Ranges attribute (covered in the next steps) to
appear in the FlexUNI Attribute window.
Step 2
Check the Inner VLAN Ranges check box to enable the range of inner VLAN tags to be specified
during service request creation.
If the check box is unchecked, the range of inner VLAN tags are not allowed. In this case, the operator
must specify discrete VLAN IDs during service request creation.
Step 3
Continue with the steps contained in the next section, Setting the VLAN Rewrite Criteria Attributes,
page 3-14.
Setting the VLAN Rewrite Criteria Attributes
Together with VLAN matching criteria, VLAN rewrite makes the FlexUNI/EVC infrastructure very
powerful and flexible. The following VLAN rewrite options are supported:
•
Pop one or two tags.
•
Push one or two tags.
•
Translation (1:1, 2:1, 1:2, 2:2).
Be aware of the following considerations when setting the VLAN rewrite criteria attributes:
•
Only one kind of rewrite can be done on every CE-facing FlexUNI link.
•
All VLAN rewrites are done using the symmetric keyword on the ingress traffic (for example,
rewrite ingress tag pop 2 symmetric).
•
For any service instance, only one type of rewrite option (pop, push, or translate) is allowed per
instance. For example, if pop out is enabled, push inner, push outer, translate inner, and translate
outer are not available.
To set the FlexUNI VLAN rewrite criteria attributes, perform the following steps.
Step 1
Check the Pop Outer check box to pop the outer VLAN ID tag of the incoming frames that fulfill the
match criteria.
If this check box is unchecked, the outer tag of the incoming traffic is not popped.
Step 2
Check the Pop Inner check box to pop the inner VLAN ID tag of the incoming frames that fulfill the
match-criteria.
If this check box is unchecked, the inner tag is not popped. Note that, if Pop Inner is checked, Pop Outer
is automatically checked.
Step 3
Check the Push Outer check box to impose an outer VLAN ID tag onto the incoming frames that fulfill
the match criteria.
If this check box is unchecked, no outer tag is imposed on the incoming frames.
Usage notes:
•
If Push Outer is checked, all service requests created with the policy push a dot1q outer tag on the
incoming frames matching the match criteria. When creating the link during service creation, the
operator can specify an outer tag with a value from 1 to 4096.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-14
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the FlexUNI Attributes
Step 4
•
This attribute is available regardless of the number of tags used in the match criteria. Whether the
incoming traffic is double tagged or single tagged, if Push Outer is enabled, all corresponding
service requests push an outer tag. All subsequent nodes consider only the outer-most two tags (if
FlexUNI-capable) or just one tag (not FlexUNI-capable) and treat the inner-most tags transparently
as payload.
•
This VLAN ID is not derived from ISC-managed VLAN ID pools.
Check the Push Inner check box to impose an inner VLAN ID tag onto the incoming frames that fulfill
the match criteria.
This operation pushes both an inner and an outer tag onto the incoming packet, not just an inner tag. If
this check box is unchecked, no inner tag is imposed on the incoming frames.
Usage notes:
Step 5
•
If Push Inner is checked, all service requests created with the policy push a dot1q inner tag on the
incoming frames matching the match criteria. When creating the link during service creation, the
operator can specify an inner tag with a value from 1 to 4096.
•
If Push Inner is checked, Push Outer is automatically checked.
•
This attribute is available regardless of the number of tags used in the match criteria. Regardless of
whether the incoming traffic is double tagged or single tagged, if Push Inner is enabled, all
corresponding service requests push an inner tag. All subsequent nodes consider only the outer-most
two tags (if FlexUNI-capable) or just one tag (not FlexUNI-capable) and treat the inner-most tags
transparently as payload.
•
This VLAN ID is not derived from ISC-managed VLAN ID pools.
Check the Translate Outer check box to allow the operator to specify a target outer VLAN ID during
service request creation.
The outer tag of all the incoming frames that fulfill the match criteria are translated to this ID. If the
check box is unchecked, no outer tag translation is performed. See Table 3-1.
Step 6
Check the Translate Inner check box to allow the operator to specify a target inner VLAN ID during
service request creation.
The inner tag of all the incoming frames that fulfill the match criteria are translated to this ID. If the
check box is unchecked, no inner tag translation is performed. See Table 3-1.
Note
Table 3-1 summarizes the realization of different VLAN translations available in the FlexUNI/EVC
infrastructure. The second and third columns (Match Outer Tag and Match Inner Tag) refer to policy
settings. The last two columns (Translate Outer Tag and Translate Inner Tag) indicate the VLAN
translation that occurs on the incoming frames.
Table 3-1
Step 7
VLAN Translation Summary Table
Type
Match Outer Tag
Match Inner Tag
Translate Outer Tag
Translate Inner Tag
1:1
True
N/A
Yes
No
1:2
True
N/A
Yes
Yes
2:1
True
True
Yes
No
2:2
True
True
Yes
Yes
Click Next.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-15
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
The EVC Policy Editor - Interface Attribute window appears, as shown in Figure 3-3.
Step 8
Continue with the steps contained in the next section, Setting the Interface Attributes, page 3-16.
Setting the Interface Attributes
This step of creating the FlexUNI/EVC Ethernet policy involves setting the interface attributes, as shown
in the EVC Policy Editor - Interface Attribute window in Figure 3-4. The attributes you can configure in
this window are grouped under the following categories:
•
N-PE/U-PE information
•
Speed and duplex information
•
ACL name and MAC addresses
•
UNI port security
•
Storm control
•
L2 protocol tunneling
In some cases, checking an attribute causes additional attributes to appear in the GUI. This is covered in
the steps that follow.
Note
If the CE is directly connected to an N-PE, only speed, duplex, UNI shutdown, and other generic options
are presented. In this case, port security, storm control, L2 protocol tunneling, and other advanced
features are not supported due to the current platform limitations. If these features are needed for a
service, the service provider must deploy Layer 2 Ethernet access nodes beyond the FlexUNI to support
these requirements.
Note
Attributes available in the Interface Attributes window dynamically change based on the choice made
for the MPLS Core Connectivity Type (PSEUDOWIRE, LOCAL, or VPLS) in the Service Options
window (see Setting the Service Options, page 3-8). For completeness, all attributes available for the
different core types are documented in the following steps. Attributes apply to all core types, unless
otherwise noted.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-16
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
Figure 3-4
EVC Policy Editor - Interface Attributes Window
To set the FlexUNI/EVC interface attributes, perform the following steps.
Step 1
Choose an Encapsulation type.
The choices are:
Step 2
•
DOT1QTRUNK—Configures the UNI as a trunk with 802.1q encapsulation. If the UNI belongs to
a directly connected and FlexUNI link, this setting signifies that the incoming frames are 802.1q
encapsulated and that they match the VLAN ID configured for the link. This specific topology does
not involve a trunk UNI as such.
•
DOT1QTUNNEL—Configures the UNI as an 802.1q tunnel (also known as a dot1q tunnel or
Q-in-Q) port.
•
ACCESS—Configures the UNI as an access port.
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 3
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-17
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
Step 4
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable, in order to support modification on a per-service request basis.
Step 5
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 6
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 7
Check the Use Existing ACL Name check box if you want to assign your own named access list to the
port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 8
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
Step 9
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 10
Check the UNI Port Security check box (see Figure 3-5) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-18
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
Figure 3-5
Step 11
UNI Port Security
Check the Enable Storm Control check box (see Figure 3-6) to help prevent the UNI port from being
disrupted by a broadcast, multicast, or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 3-6
Step 12
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 3-7) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 3-7
Protocol Tunnelling
For each protocol that you choose, enter the shutdown threshold and drop threshold for that protocol:
a.
Enable cdp—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
cdp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-19
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
Step 13
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Enable vtp—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
vtp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Enable stp—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
stp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Check the N-PE Pseudo-wire on SVI check box to have ISC generate forwarding commands under SVIs
(switch virtual interfaces).
By default, this check box is not checked. In this case, ISC generates forwarding commands under the
service instance.
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (this is available in the policy workflow in the EVC Policy Editor Service Options window). N-PE Pseudo-wire on SVI, if enabled, will be reflected only when Configure
with Bridge Domain is set to true. Otherwise, the service request will not be created with xconnect under
SVI, even if N-PE Pseudo-wire on SVI is enabled.
Usage notes:
•
ISC supports a hybrid configuration for FlexUNI/EVC service requests. In a hybrid configuration,
the forwarding commands (such as xconnect) for one side of an attachment circuit can be configured
under a service instance, and the xconnect configuration for the other side of the attachment circuit
can be configured under a switch virtual interface (SVI).
•
For examples of these cases, see configlet examples FlexUNI/EVC (Pseudowire Core Connectivity,
Bridge Domain, Pseudowire on SVI) and FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge
Domain, no Pseudowire on SVI).
•
N-PE Pseudo-wire on SVI is applicable for all connectivity types (PSEUDOWIRE, VPLS, and
LOCAL), but a hybrid SVI configuration is possible only for pseudowire connectivity.
•
When MPLS Core Connectivity Type is set as VPLS, the N-PE Pseudo-wire on SVI attribute is
always enabled in the policy and service request.
•
When MPLS Core Connectivity Type is set as LOCAL connectivity type, the N-PE Pseudo-wire on
SVI attribute is always disabled in the policy and service request.
•
The N-PE Pseudo-wire on SVI attribute is not supported for IOS XR devices. Only subinterfaces are
supported on ASR 9000 devices; service instance is not supported. All the xconnect commands are
configured on L2 subinterfaces.
•
Table 3-2 shows various use cases for hybrid configuration for FlexUNI/EVC service requests.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-20
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
Table 3-2
Use Bridge
Domain
FlexUNI
N-PE
Pseudowire
on SVI
True
True
True
True
False
Step 14
Use Cases for Hybrid Configuration for FlexUNI /EVC Service Requests
True
True
False
N/A
CLIs Generated
•
xconnect under VLAN interface.
•
Service instance under main interface.
•
xconnect under service instance.
•
Service instance under main interface.
•
xconnect under service instance.
•
Service instance under main interface.
True
False
True
xconnect under VLAN interface.
True
False
False
xconnect under subinterface.
False
False
False
xconnect under subinterface.
Specify the type of VLAN Translation for this policy by clicking the appropriate radio button.
The choices are:
Step 15
•
No—No VLAN translation is performed. (This is the default.)
•
1:1—1:1 VLAN translation.
•
2:1—2:1 VLAN translation.
Note
For detailed coverage of setting up VLAN translation, see Appendix C, “Setting Up VLAN
Translation.”
Note
VLAN translation is only supported on links that are specified as non-FlexUNI at the service
request level.
Enter the MTU Size in bytes.
The maximum transmission unit (MTU) size is configurable and optional. The default size is 9216, and
the range is 1500 to 9216. ISC does not perform an integrity check for this customized value. If a service
request goes to the Failed Deploy state because this size is not accepted, you must adjust the size until
the Service Request is deployed.
In ISC 6.0, different platforms support different ranges.
Step 16
•
For the 3750 and 3550 platforms, the MTU range is 1500 to 1546.
•
For the Cisco 7600 Ethernet port, the MTU size is always 9216. Even with the same platform and
same IOS release, different line cards support the MTU differently. For example, older line cards
only take an MTU size of 9216 and newer cards support 1500 to 9216. However, ISC 6.0 uses 9216
in both cases.
•
For the Cisco 7600 SVI (interface VLAN), the MTU size is 1500 to 9216.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-21
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Setting the Interface Attributes
This attribute is unchecked by default.
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Step 17
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is unchecked by default.
Usage notes:
Step 18
•
The pseudowire class name is used for provisioning pw-class commands on IOS XR devices. See
Creating and Modifying Pseudowire Classes for IOS XR Devices, page 2-10 for additional
information on pseudowire class support for IOS XR devices.
•
If Use PseudoWireClass is checked, an additional attribute, PseudoWireClass, appears in the GUI.
Click the Select button of PseudoWireClass attribute to choose a pseudowire class previously
created in ISC.
•
The Use PseudoWireClass attribute is only available if the MPLS core connectivity type was set as
PSEUDOWIRE in the Service Options window (see Setting the Service Options, page 3-8).
•
Use PseudoWireClass is only applicable for IOS XR devices.
For L2VPN Group Name choose one of the following from the drop-down list:
•
ISC
•
VPNSC
Usage notes:
•
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 19
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the
drop-down list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
•
The L2VPN Group Name attribute is not available if the MPLS core connectivity type was set as
VPLS in the Service Options window (see Setting the Service Options, page 3-8).
•
L2VPN Group Name is only applicable for IOS XR devices.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
Usage notes:
•
If no value is specified for the E-Line Name in either the policy or the service request based on the
policy, ISC autogenerates a default name as follows:
– For PSEUDOWIRE core connectivity type, the format is:
DeviceName--VC_ID
– For LOCAL core connectivity type, the format is:
DeviceName--0--VLAN_ID
If the default name is more than 32 characters, the device names are truncated.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-22
OL-21636-01
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Enabling Template Association
Step 20
•
The E-Line Name attribute is not available if the MPLS core connectivity type was set as VPLS in
the Service Options window (see Setting the Service Options, page 3-8).
•
E-Line Name is only applicable for IOS XR devices.
If you would like to enable template association for this policy, click the Next button.
See the section Enabling Template Association, page 3-23 for information about this feature.
Step 21
To save the FlexUNI/EVC policy, click Finish.
To create a service request based on a FlexUNI/EVC policy, see Chapter 4, “Managing a FlexUNI/EVC
Ethernet Service Request.”
Enabling Template Association
The ISC template feature gives you a means to download free-format CLIs to a device. If you enable
templates, you can create templates and data files to download commands that are not currently
supported by ISC.
Step 1
To enable template association for the policy, click the Next button in EVC Policy Editor - Interface
Attribute window (before clicking Finish).
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”.
Step 2
When you have completed setting up templates and data files for the policy, click Finish in the Template
Association window to close it and return to the Policy Editor window.
Step 3
To save the FlexUNI/EVC policy, click Finish.
To create a service request based on a FlexUNI/EVC policy, see Chapter 4, “Managing a FlexUNI/EVC
Ethernet Service Request.”
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
3-23
Chapter 3
Creating a FlexUNI/EVC Ethernet Policy
Enabling Template Association
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
3-24
OL-21636-01
CH A P T E R
4
Managing a FlexUNI/EVC Ethernet Service
Request
This chapter provides information on how to provision a FlexUNI/EVC Ethernet service request. It
contains the following sections:
•
Introducing FlexUNI/EVC Service Requests, page 4-1
•
Creating a FlexUNI/EVC Service Request, page 4-2
•
Setting the Service Request Details, page 4-2
•
Modifying the FlexUNI/EVC Service Request, page 4-21
•
Using Templates and Data Files with a FlexUNI/EVC Ethernet Service Request, page 4-22
•
Saving the FlexUNI/EVC Service Request, page 4-23
Introducing FlexUNI/EVC Service Requests
A FlexUNI/EVC Ethernet service request allows you to configure interfaces on an N-PE to support the
FlexUNI/EVC features described in Chapter 3, “Creating a FlexUNI/EVC Ethernet Policy.” To create a
FlexUNI/EVC service request, a FlexUNI/EVC service policy must already be defined, as described in
Chapter 3, “Creating a FlexUNI/EVC Ethernet Policy.” Based on the predefined FlexUNI/EVC policy,
an operator creates a FlexUNI/EVC service request, with or without modifications to the policy, and
deploys the service. One or more templates can also be associated to the N-PE as part of the service
request.
Creating a FlexUNI/EVC Ethernet service request involves the following steps:
•
Choose an existing FlexUNI/EVC Ethernet policy.
•
Choose a VPN.
Note
When working with VPN objects in the context of FlexUNI/EVC Ethernet policies and service
requests, only the VPN name and customer attributes are relevant. Other VPN attributes related
to MPLS and VPLS are ignored.
•
Specify a bridge domain configuration (if applicable).
•
Specify a service request description.
•
Specify automatic or manual allocation of the VC ID or VPLS VPN ID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-1
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Creating a FlexUNI/EVC Service Request
•
Add direct connect links (if applicable).
•
Add links with L2 access nodes (if applicable).
•
Choose the N-PE and UNI interface for links.
•
For links with L2 access nodes, choose a Named Physical Circuit (NPC) if more than one NPC exists
from the N-PE or the UNI interface.
•
Edit the link attributes.
•
Modify the service request.
•
Save the service request.
For sample configlets for ATM-Ethernet Interworking scenarios, see Appendix A, “Sample Configlets.”
Creating a FlexUNI/EVC Service Request
To create a FlexUNI/EVC Ethernet service request, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears.
Step 2
Click Create.
Step 3
Choose FlexUNI (EVC) from the drop-down list.
The Select EVC Policy window appears. If more than one FlexUNI/EVC policy exists, a list of
FlexUNI/EVC policies appears. FlexUNI/EVC service requests must be associated with a FlexUNI/EVC
policy. You choose a FlexUNI/EVC policy from the policies previously created (see Chapter 3,
“Creating a FlexUNI/EVC Ethernet Policy”).
Step 4
Choose a FlexUNI/EVC Ethernet policy from the list.
Step 5
Click OK.
The EVC Service Request Editor window appears. The new service request inherits all the properties of
the chosen FlexUNI/EVC policy, such as all the editable and non-editable features and pre-set
parameters.
Step 6
Continue with the steps contained in the next section, Setting the Service Request Details, page 4-2.
Setting the Service Request Details
After you have selected the FlexUNI/EVC Ethernet policy to be used as the basis of the service request,
the EVC Service Request Editor window appears. It is divided into three main sections:
•
Service Request Details
•
Direct Connect Links (no NPCs)
•
Links with L2 Access Nodes (involves NPCs)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-2
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
This window enables you to specify options for the service request, as well as configure directly
connected links and links with L2 access nodes. The options displayed in first section of the window
change, depending on the MPLS Core Connectivity Type that was specified in the policy (pseudowire,
VPLS, or local). For clarity, each of these scenarios is presented in a separate section below, to highlight
the different window configurations and behavior of the displayed options.
Proceed to the appropriate section, as determined by the MPLS Core Connectivity Type for the policy:
•
Pseudowire Core Connectivity, page 4-3
•
VPLS Core Connectivity, page 4-5
•
Local Core Connectivity, page 4-7
Instructions for setting up direct connect links and links with L2 access nodes are presented in later
sections.
Pseudowire Core Connectivity
If the MPLS Core Connectivity Type for the FlexUNI/EVC Ethernet policy is PSEUDOWIRE, the EVC
Service Request Editor window shown Figure 4-1 appears.
Figure 4-1
EVC Service Request Details Window for Pseudowire Core Connectivity
Perform the following steps to set the attributes in the first section of the Service Request Details
window:
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-3
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Note
The Job ID and SR ID fields are read-only. When the service request is being created for the first time,
the fields display a value of NEW. When an existing service request is being modified, the values of the
fields indicate the respective IDs that the ISC database holds within the editing flow of the service
request.
Note
The Policy field is read-only. It displays the name of the policy on which the service request is based.
Clicking on the read-only policy name displays a list of all the attribute values set within the policy.
Step 1
Click Select VPN to choose a VPN for use with this service request.
The Select VPN window appears with the VPNs defined in the system.
Note
The same VPN can be used by service requests with LOCAL and PSEUDOWIRE core types. If
a VPN for a service request is used with VPLS core type, the same VPN cannot be used for
service requests with LOCAL or PSEUDOWIRE core type.
Step 2
Choose a VPN Name in the Select column.
Step 3
Click Select.
The EVC Service Request Editor window appears with the VPN name displayed.
Step 4
Check the AutoPick VC ID check box if you want ISC to choose a VC ID.
If you do not check this check box, you will be prompted to provide the ID in the VC ID field, as covered
in the next step.
When AutoPick VC ID is checked, ISC allocates a VC ID for pseudowires from the ISC-managed VC
ID resource pool. In this case, the text field for the VC ID option is non-editable.
Step 5
If AutoPick VC ID was unchecked, enter a VC ID in the VC ID field.
Usage notes:
Step 6
•
The VC ID value must be an integer value corresponding to a VC ID.
•
When a VC ID is manually allocated, ISC verifies the VC ID to see if it lies within ISC’s VC ID
pool. If the VC ID is in the pool but not allocated, the VC ID is allocated to the service request. If
the VC ID is in the pool and is already in use, ISC prompts you to allocate a different VC ID. If the
VC ID lies outside of the ISC VC ID pool, ISC does not perform any verification about whether or
not the VC ID allocated. The operator must ensure the VC ID is available.
•
The VC ID can be entered only while creating a service. If you are editing the service request, the
VC ID field is not editable.
Check the Enable PseudoWire Redundancy check box to enable pseudowire redundancy (alternative
termination device) under certain conditions.
See Appendix D, “Terminating an Access Ring on Two N-PEs” and, specifically, the section Using N-PE
Redundancy in FlexUNI/EVC Service Requests, page D-3, for notes on how this option can be used.
Step 7
If the AutoPick VC ID attribute was unchecked, enter a VC ID for the backup pseudowire in the Backup
PW VC ID field.
See the usage notes for the AutoPick VC ID attribute in Step 7, above. The backup VC ID behaves the
same as the VC ID of the primary pseudowire.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-4
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Step 8
Check the Configure Bridge Domain check box to determine bridge domain characteristics.
The behavior of the Configure Bridge Domain option works in tandem with the choice you selected in
the MPLS Core Connectivity Type option in the FlexUNI/EVC policy, which in this case is pseudowire
core connectivity. There are two cases:
•
With FlexUNI:
– If Configure With Bridge Domain is checked, the policy will configure pseudowires under
SVIs associated to the bridge domain.
– If Configure With Bridge Domain is unchecked, the policy will configure pseudowires
directly under the service instance. This will conserve the global VLAN.
•
Without FlexUNI:
– If Configure With Bridge Domain is checked, the policy will configure pseudowires under
SVIs.
– If Configure With Bridge Domain is unchecked, the policy will configure pseudowires
directly under subinterfaces.
Pseudowires can be configured either directly under service instance of the corresponding
FlexUNI-capable interface or under SVIs associated to the bridge domain.
Step 9
Check the Use Split Horizon check box to enable split horizon with bridge domain.
Usage notes:
Step 10
•
The Use Split Horizon attribute is disabled by default.
•
The Use Split Horizon attribute can be used only when the Configure Bridge Domain check box is
checked (enabled).
•
When Use Split Horizon is enabled, the bridge domain command in the CLI will be generated with
split horizon. When it is disabled, the bridge domain command will be generated without split
horizon.
Click the “Click here” link of the Description attribute to enter a description label for the service
request.
This is useful for searching the ISC database for the particular service request.
A dialogue appears in which you can enter a description.
Step 11
To set up direct connect links, see the section Setting Direct Connect Links, page 4-10.
Step 12
To set up links with L2 access nodes, see the section Setting Links with L2 Access Nodes, page 4-20.
VPLS Core Connectivity
If the MPLS Core Connectivity Type for the FlexUNI/EVC Ethernet policy is VPLS, the EVC Service
Request Editor window shown Figure 4-2 appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-5
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Figure 4-2
EVC Service Request Details Window for VPLS Core Connectivity
Perform the following steps to set the attributes in the first section of the Service Request Details
window:
Step 1
The Job ID and SR ID fields are read-only.
When the service request is being created for the first time, the fields display a value of NEW. When an
existing service request is being modified, the values of the fields indicate the respective IDs that the ISC
database holds within the editing flow of the service request.
Step 2
The Policy field is read-only. It displays the name of the policy on which the service request is based.
Step 3
Click Select VPN to choose a VPN for use with this service request.
The Select VPN window appears with the VPNs defined in the system.
Note
The same VPN can be used by service requests with LOCAL and PSEUDOWIRE core types. If
a VPN for a service request is used with VPLS core type, the same VPN cannot be used for
service requests with LOCAL or PSEUDOWIRE core type.
Note
If the same VPN is used among multiple service requests, all having VPLS core type, then all
these service requests participate in the same VPLS service.
Step 4
Choose a VPN Name in the Select column.
Step 5
Click Select.
The EVC Service Request Editor window appears with the VPN name displayed.
Step 6
Check the AutoPick VPLS VPN ID check box if you want ISC to choose a VPLS VPN ID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-6
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
If you do not check this check box, you will be prompted to provide the VPN ID in the VPLS VPN ID
field, as covered in the next step.
Step 7
•
When AutoPick VPLS VPN ID is checked, ISC allocates a VPLS VPN ID from the ISC-managed
VC ID resource pool. In this case, the text field for the VPLS VPN ID option is non-editable.
•
If AutoPick VPLS VPN ID is checked and a service request already exists that refers to same VPN
object, the VPLS VPN ID of the existing service request is allocated to the new service request.
If AutoPick VPLS VPN ID was unchecked, enter a VPLS VPN ID in the VPLS VPN ID field.
Usage notes:
Step 8
•
The VPLS VPN ID value must be an integer value corresponding to a VPN ID.
•
When a VPLS VPN ID is manually allocated, ISC verifies the VPLS VPN ID to see if it lies within
ISC’s VC ID pool. If the VPLS VPN ID is in the pool but not allocated, the VPLS VPN ID is
allocated to the service request. If the VPLS VPN ID is in the pool and is already in use, ISC prompts
you to allocate a different VPLS VPN ID. If the VPLS VPN ID lies outside of the VC ID pool, ISC
does not perform any verification about whether the VPLS VPN ID allocated. The operator must
ensure the VPLS VPN ID is available.
•
The VPLS VPN ID can be entered only while creating a service. If you are editing the service
request, the VPLS VPN ID field is not editable.
The Configure Bridge Domain check box is check by default and cannot be changed.
Usage notes:
Step 9
•
For VPLS, all configurations are under the SVI.
•
When the FlexUNI feature is used, all configurations are under the SVI and also associated to a
bridge domain.
Check the Use Split Horizon check box to enable split horizon with bridge domain.
Usage notes:
Step 10
•
The Use Split Horizon attribute is disabled by default.
•
The Use Split Horizon attribute can be used only when the Configure Bridge Domain check box is
checked (enabled).
•
When Use Split Horizon is enabled, the bridge domain command in the CLI will be generated with
split horizon. When it is disabled, the bridge domain command will be generated without split
horizon.
Click the “Click here” link of the Description attribute to enter a description label for the service
request.
A dialogue appears in which you can enter a description.
Step 11
To set up direct connect links, see the section Setting Direct Connect Links, page 4-10.
Step 12
To set up links with L2 access nodes, see the section Setting Links with L2 Access Nodes, page 4-20.
Local Core Connectivity
If the MPLS Core Connectivity Type for the FlexUNI/EVC Ethernet policy is LOCAL, the EVC Service
Request Editor window shown Figure 4-3 appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-7
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Figure 4-3
EVC Service Request Details Window for Local Core Connectivity
Perform the following steps to set the attributes in the first section of the Service Request Details
window:
Step 1
The Job ID and SR ID fields are read-only.
When the service request is being created for the first time, the fields display a value of NEW. When an
existing service request is being modified, the values of the fields indicate the respective IDs that the ISC
database holds within the editing flow of the service request.
Step 2
The Policy field is read-only.
It displays the name of the policy on which the service request is based.
Step 3
Click Select VPN to choose a VPN for use with this service request.
The Select VPN window appears with the VPNs defined in the system.
Note
The same VPN can be used by service requests with LOCAL and PSEUDOWIRE core types. If
a VPN for a service request is used with VPLS core type, the same VPN cannot be used for
service requests with LOCAL or PSEUDOWIRE core type.
Step 4
Choose a VPN Name in the Select column.
Step 5
Click Select.
The EVC Service Request Editor window appears with the VPN name displayed.
Step 6
Check the Configure Bridge Domain check box to determine bridge domain characteristics.
Usage notes:
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-8
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
•
If Configure Bridge Domain is checked, all links will have the same bridge domain ID allocated
from the VLAN pool on the N-PE. All non-FlexUNI links will have the Service Provider VLAN as
the bridge domain ID. On the other hand, if no FlexUNI links are added, the Service Provider VLAN
will be allocated first and this will be used as the bridge domain ID when FlexUNI links are added.
•
If Configure Bridge Domain is unchecked, a maximum of two links that terminate on the same N-PE
can be added. (This uses the connect command available in the EVC infrastructure.)
Note
See the following comments for details on how ISC autogenerates the connect name.
Because the device only accepts a maximum of 15 characters for the connect name, the connect
name is generated using the following format:
CustomerNameTruncatedToMaxPossibleCharacters_ServiceRequestJobID
For example, if the customer name is NorthAmericanCustomer and the service request job ID is
56345, the autogenerated connect name would be NorthAmer_56345.
The CLI generated would be:
connect NorthAmer_56345 GigabitEthernet7/0/5 11 GigabitEthernet7/0/4 18
In this case, 11 and 18 are service instance IDs.
•
Step 7
If the policy setting for Configure Bridge Domain is non-editable, the option in the service request
will be read-only.
Check the Use Split Horizon check box to enable split horizon with bridge domain.
Usage notes:
Step 8
•
The Use Split Horizon attribute is disabled by default.
•
The Use Split Horizon attribute can be used only when the Configure Bridge Domain check box is
checked (enabled).
•
When Use Split Horizon is enabled, the bridge domain command in the CLI will be generated with
split horizon. When it is disabled, the bridge domain command will be generated without split
horizon.
Click the “Click here” link of the Description attribute to enter a description label for the service
request.
A dialogue appears in which you can enter a description.
Step 9
To set up direct connect links, see the section Setting Direct Connect Links, page 4-10.
Step 10
To set up links with L2 access nodes, see the section Setting Links with L2 Access Nodes, page 4-20.
Setting up Links to the N-PE
The lower two sections of the EVC Service Request Editor window allow you to set up links to the N-PE.
For direct connect links, the CE is directly connected to the N-PE, with no intermediate L2 access nodes.
For links with L2 access nodes, there are intermediate devices present between the CE and NPE
requiring NPCs to be created in ISC.
The Direct Connect Link section of the window is where you set up links that directly connect to the
N-PE. No NPC are involved. The Links with L2 Access Nodes section is where you set up links with L2
(Ethernet) access nodes. NPCs are involved.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-9
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
See the appropriate section, depending on which type of link you are setting up:
Note
•
Setting Direct Connect Links, page 4-10
•
Setting Links with L2 Access Nodes, page 4-20
Many of steps for setting up the two link types are the same. The basic workflow for setting up links, as
well as the attributes to be set, are presented in the section Setting Direct Connect Links, page 4-10. Even
if you are setting up links with L2 access nodes, it will be helpful to refer to the information presented
in that section, as the section on L2 access nodes only covers the unique steps for such links.
Setting Direct Connect Links
Perform the following steps to set up the direct connect links. Most of these steps apply to links with L2
access nodes also.
Step 1
Click Add to add a link.
A new numbered row for the link attributes appears.
Step 2
Click Select NPE in N-PE column.
The Select PE Device window appears. This window displays the list of currently defined PEs.
a.
The Show PEs with drop-down list shows PEs by Provider, PE Region Name, or by Device Name.
b.
The Find button allows a search for a specific PE or a refresh of the window.
c.
The Rows per page drop-down list allows the user to configure the number of entries displayed on
the screen at one time.
Step 3
In the Select column, choose the PE device name for the link.
Step 4
Click Select.
The EVC Service Request Editor window reappears displaying the name of the selected PE in the NPE
column.
Step 5
Choose the UNI interface from the drop-down list in the UNI column.
Note
ISC only displays the available interfaces for the service, based on the configuration of the underlying
interfaces, existing service requests that might be using the interface, and the customer associated with
the service request. You can click the Details button to display a pop-up window with information on
the available interfaces, such as interface name, customer name, VPN name, job ID, service request ID,
service request type, translation type, and VLAN ID information.
Note
When the UNI is configured on an N-PE device running IOS XR, the Standard UNI Port attribute is not
supported. All the CLIs related to Standard UNI Port and UNI Port Security are ignored in this case.
Step 6
Note
Check the FlexUNI check box to mark the link for configuring service instance for the links.
The FlexUNI check box is mentioned at this stage because the setting of the check box alters the
behavior of the link editing function available in the Link Attributes column. This is covered in the next
steps.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-10
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Editing the Link Attributes
The next steps document the use of the Edit link in the Link Attributes column. (In the case where the
link attributes have already been set, this link changes from Edit to Change.) The link editing workflow
changes depending on the status of the FlexUNI check box for the link. If the FlexUNI check box is
checked, the editing workflow involves setting attributes in two windows, for two sets of link attributes:
•
The FlexUNI Details
•
Standard UNI Details
If the FlexUNI check box for the link is not checked, only the Standard UNI Details window is presented.
In the steps that follow, both scenarios covered.
Step 7
Click Edit in the Link Attributes column to specify the UNI attributes.
FlexUNI Details Window
If the FlexUNI check box is checked, the FlexUNI Details window appears, as shown in Figure 4-4.
Figure 4-4
FlexUNI Details Window
All of the fields in the FlexUNI Details screen are enabled based on the policy settings. For example, if
Both Tags is selected in the policy and is editable, then the Match Inner and Outer Tags check box will
be selected and editable in this window. The behavior is similar for the other attributes in the FlexUNI
Details window
Step 8
Check the AutoPick Service Instance ID check box to specify that the service instance ID will be
autogenerated and allocated to the link during service request creation.
If the check box is unchecked, you must specify the service instance ID (see the next step).
Usage notes:
•
The service instance ID represents an Ethernet Flow Point (EFP) on an interface in the EVC
infrastructure. The service instance ID is locally significant to the interface. This ID has to be unique
only at the interface level. The ID must be a value from 1 to 8000.
•
There are no resource pools available in ISC from which to allocate the service instance IDs.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-11
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Step 9
•
In the case of a manually provided service instance ID, it is the responsibility of the operator to
maintain the uniqueness of the ID at the interface level.
•
This attribute is not displayed for IOS XR devices.
If the AutoPick Service Instance ID check box is not checked, enter an appropriate value for the service
instance ID in the Service Instance ID field.
This attribute is not displayed for IOS XR devices.
Step 10
Check the AutoPick Service Instance Name check box to specify that the service instance name will
be autogenerated.
If the check box is unchecked, you can specify the service instance name (see the next step).
Usage notes:
Step 11
•
If the check box is checked, the Service Instance Name text field is disabled.
•
The service instance name is autogeneratedi n the following pattern:
CustomerName_ServiceRequestJobID.
•
For example configlets, see FlexUNI/EVC (No AutoPick Service Instance Name, No Service
Instance Name), page A-42, FlexUNI/EVC (User-Provided Service Instance Name, Pseudowire
Core Connectivity), page A-43, and FlexUNI/EVC (User-Provided Service Instance Name, Local
Core Connectivity), page A-44.
•
This attribute is not displayed for IOS XR devices.
If the AutoPick Service Instance Name check box is not checked, enter an appropriate value for the
service instance ID in the Service Instance Name field.
Usage notes:
Step 12
•
The text string representing the service instance name must be 40 characters or less and contain no
spaces. Other special characters are allowed.
•
If AutoPick Service Instance Name is unchecked and no service instance name is entered in the text
field, then ISC does not generate the global ethernet evc evcname command in the device
configuration generated by the service request.
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID for the
service request during service request creation.
If this check box is unchecked, the you must specify a bridge domain VLAN ID (see the next step).
Usage notes:
Step 13
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain VLAN ID is picked from the existing ISC VLAN pool.
If the AutoPick Bridge Domain/VLAN ID check box is unchecked, enter an appropriate value in the
Bridge Domain/VLAN ID field.
Note
This configuration applies in conjunction with the Configure Bridge Domain option in the EVC
Service Request Editor window. If the option is not enabled in that window, then AutoPick
Bridge Domain/VLAN ID check box is redundant and not required.
When a VLAN ID is manually allocated, ISC verifies the VLAN ID to see if it lies within ISC’s VLAN
ID pool. If the VLAN ID is in the pool but not allocated, the VLAN ID is allocated to the service request.
If the VLAN ID is in the pool and is already in use, ISC prompts you to allocate a different VLAN ID.
If the VLAN ID lies outside of the ISC VLAN ID pool, ISC does not perform any verification about
whether the VLAN ID allocated. The operator must ensure the VLAN ID is available.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-12
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Step 14
Check the Match Inner and Outer Tags check box to enable service requests created with the policy
to match both the inner and outer VLAN tags of the incoming frames.
If you do not check this check box, service requests created with the policy will match only the outer
VLAN tag of the incoming frames.
Checking the Match Inner and Outer Tags attribute causes the Inner VLAN ID and Outer VLAN ID
fields (covered in the next steps) to appear.
Step 15
If the Match Inner and Outer Tags check box is checked, enter the inner and outer VLAN tags in the
Inner VLAN ID and Outer VLAN ID fields.
Usage notes:
•
You can specify single values, single ranges, multiples values, multiple ranges, or combinations of
these. Examples:
– 10
– 10, 15,17
– 10-15
– 10-15,17-20
– 10,20-25
•
Step 16
Note
Step 17
If the Inner VLAN Ranges attribute is set to true in the policy, the Inner VLAN ID field can take a
range of inner VLAN tags.
If the Match Inner and Outer Tags check box is unchecked, enter the outer VLAN tag in the Outer
VLAN ID field.
The VLAN specified in Outer VLAN ID will be provisioned on the rest of the L2 access nodes (if the
link has any), including the customer-facing UNI.
In the VLAN Rewrite section of the window, choose a Rewrite Type from the drop-down list.
The choices are:
•
Pop
•
Push
•
Translate
The subsequent attributes in the GUI change depending on the choice of Rewrite Type, as covered in the
next steps.
Step 18
If Pop is the Rewrite Type, two check boxes appear:
a.
Check the Pop Outer Tag check box to pop the outer VLAN ID tag of the incoming frames that
fulfill the match criteria. If this check box is unchecked, the outer tag of the incoming traffic will
not be popped.
b.
Check the Pop Inner Tag check box to pop the inner VLAN ID tag of the incoming frames that
fulfill the match-criteria. If this check box is unchecked, the inner tag will not be changed.
Note that if Pop Inner Tag is checked, Pop Outer Tag is automatically checked.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-13
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Step 19
Step 20
If Push is the Rewrite Type, two text boxes appear:
a.
In the text box Outer VLAN ID, enter an outer VLAN ID tag that will be imposed on the incoming
frames that fulfill the match criteria. All service requests created with this setting push a dot1q outer
tag on the incoming frames matching the match criteria. If a value is not provided, the push
operation is ignored and not configured on the device.
b.
In the text box Inner VLAN ID, enter an inner VLAN ID tag that will be imposed on the incoming
frames that fulfill the match criteria. All service requests created with this setting push a dot1q inner
tag on the incoming frames matching the match criteria. The Inner VLAN tag cannot be pushed
without an Outer VLAN tag. That is, when pushing an Inner VLAN tag, the Outer VLAN tag also
must be defined.
If Translate is the Rewrite Type, a Translation Type drop-down list appears.
The choices available in this list vary depending on the setting of the Match Inner and Outer Tags
attribute (set in a previous step).
a.
If the Match Inner and Outer Tags check box is checked (true), choose a translation type of 1:1, 1:2,
2:1, or 2:2 from the Translation Type drop-down list.
– If you choose 1:1 or 2:1, enter a value in the Outer VLAN ID text box that appears. The outer
tag of all the incoming frames that fulfill the match criteria will be translated to this ID.
– If you choose 1:2 or 2:2, enter values in the Outer VLAN ID and Inner VLAN ID text boxes
that appear. The outer and inner tags of all the incoming frames that fulfill the match criteria
will be translated to these IDs.
b.
If the Match Inner and Outer Tags check box is unchecked (false), choose a translation type of 1:1
or 1:2 from the Translation Type drop-down list.
– If you choose 1:1, enter a value in the Outer VLAN ID text box that appears. The outer tag of
all the incoming frames that fulfill the match criteria will be translated to this ID.
– If you choose 1:2, enter values in the Outer VLAN ID and Inner VLAN ID text boxes that
appear. The outer and inner tags of all the incoming frames that fulfill the match criteria will be
translated to these IDs.
Step 21
Clicked Next to save the settings in the FlexUNI Details window.
The Standard UNI Details window appears, as shown in Figure 4-6.
Step 22
Continue with setting the standard UNI link attributes in the next steps.
Editing the Standard UNI Attributes
The following steps cover setting the attributes in the Standard UNI Details window. In the case of a link
which is not set as a FlexUNI link (by not checking the FlexUNI check box in the Service Request
Details window), editing the link attributes begins with this window.
Note
The attributes that appear in the Standard UNI Details window are dynamically configured by ISC. Some
of the attributes covered in the steps below might not appear in the window, depending on the policy and
service request settings or the link type. For example, if the MPLS core connectivity type of the
FlexUNI/EVC policy is VPLS or local, the pseudowire-related attributes will not appear. Also, setting
the link as FlexUNI or non-FlexUNI will change the attributes that appear in the window. In addition,
attributes are filtered based on device type (IOS or IOS XR). These and other cases are noted in the steps,
for reference.
Some possible presentations of the Standard UNI attributes are shown in Figure 4-5 through Figure 4-7.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-14
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Figure 4-5 is an example of a direct connect link for a Cisco 7600 device running IOS with pseudowire
core connectivity, configure bridge domain enabled, and the FlexUNI check box checked.
Figure 4-5
Standard UNI Details Window (Cisco 7600, Configure Bridge Domain Enabled)
Figure 4-6 is an example of a direct connect link for a Cisco ASR 9000 running IOS XR with pseudowire
core connectivity, configure bridge domain enabled, and the FlexUNI check box checked.
Figure 4-6
Standard UNI Details Window (Cisco ASR 9000, Configure Bridge Domain Enabled)
Figure 4-7 is an example of a direct connect link for a Cisco ASR 9000 running IOS XR with pseudowire
core connectivity, configure bridge domain not enabled, and the FlexUNI check box checked.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-15
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Figure 4-7
Step 23
Standard UNI Details Window (Cisco ASR 9000, Configure Bridge Domain not
Enabled)
The N-PE/U-PE Information and Interface Name fields display the PE device and interface name
selected in previous steps.
These fields are read-only.
Step 24
Choose an Encapsulation type from the drop-down list.
The choices are:
•
DOT1QTRUNK—Configures the UNI as a trunk with 802.1q encapsulation. If the UNI belongs to
a directly connected and FlexUNI link, this setting signifies that the incoming frames are 802.1q
encapsulated and that they match the VLAN ID configured for the link. This specific topology does
not involve a trunk UNI as such.
•
DOT1QTUNNEL—Configures the UNI as an 802.1q tunnel (also known as a dot1q tunnel or
Q-in-Q) port.
•
ACCESS—Configures the UNI as an access port.
This attribute allows you to deploy different types of UNI encapsulation on different links of a service.
Usage notes:
•
When a U-PE running with IOS is added in the same circuit terminating on an ASR 9000
(functioning in an N-PE role), the all three encapsulation types values will be visible in the
drop-down list of the Encapsulation attribute.
•
DOT1Q TUNNEL is not directly supported for ASR 9000 devices.
Step 25
In the PE/UNI Interface Description field, enter a description for the interface, if desired.
Step 26
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation
(for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time).
Step 27
Specify the type of VLAN Translation for the service request by clicking the appropriate radio button.
The choices are:
•
No—No VLAN translation is performed. (This is the default.)
•
1:1—1:1 VLAN translation.
•
2:1—2:1 VLAN translation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-16
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Note
For detailed coverage of setting up VLAN translation, see Appendix C, “Setting Up VLAN
Translation.”
This attribute is not displayed for IOS XR devices.
Step 28
Check the N-PE Pseudo-wire on SVI check box to have ISC generate forwarding commands under SVIs
(switch virtual interfaces).
By default, this check box is not checked. In this case, ISC generates forwarding commands under the
service instance.
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (this is available in the service request workflow in the EVC Service
Request Editor window). N-PE Pseudo-wire on SVI, if enabled, will be reflected only when Configure
with Bridge Domain is set to true. Otherwise, the service request will not be created with xconnect under
SVI, even if N-PE Pseudo-wire on SVI is enabled.
Usage notes:
Step 29
•
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (in the EVC Service Request Editor window). N-PE Pseudo-wire on
SVI, if enabled, will be reflected only when Configure with Bridge Domain is set to true. Otherwise,
the service request will not be created with xconnect under SVI, even if N-PE pseudo-wire on SVI
is enabled.
•
ISC supports a hybrid configuration for FlexUNI/EVC service requests. In a hybrid configuration,
the forwarding commands (such as xconnect) for one side of an attachment circuit can be configured
under a service instance, and the xconnect configuration for the other side of the attachment circuit
can be configured under a switch virtual interface (SVI).
•
N-PE Pseudo-wire on SVI is applicable for all connectivity types (PSEUDOWIRE, VPLS, and
LOCAL), but a hybrid SVI configuration is possible only for pseudowire connectivity.
•
When MPLS Core Connectivity Type is set as VPLS, the N-PE Pseudo-wire on SVI attribute is
always enabled in the policy and service request.
•
When MPLS Core Connectivity Type is set as LOCAL connectivity type, the N-PE Pseudo-wire on
SVI attribute is always disabled in the policy and service request.
•
For examples of these cases, see configlet examples FlexUNI/EVC (Pseudowire Core Connectivity,
Bridge Domain, Pseudowire on SVI) and FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge
Domain, no Pseudowire on SVI).
•
For additional information on the N-PE Pseudo-wire on SVI attribute, see the corresponding
coverage in the FlexUNI/EVC policy chapter in the section Setting the Interface Attributes.
•
The N-PE Pseudo-wire on SVI attribute is not supported for IOS XR devices. All the xconnect
commands are configured on L2 subinterfaces.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
Usage notes:
•
Checking the PW Tunnel Selection check box activates the Interface Tunnel attribute field (see the
next step).
•
This attribute only appears if the MPLS core connectivity type is set as pseudowire in the
FlexUNI/EVC policy.
•
The PW Tunnel Selection attribute is not supported for IOS XR devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-17
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Step 30
If you checked the PW Tunnel Selection check box, enter the TE tunnel ID in the Interface Tunnel text
field.
Usage notes:
•
ISC uses the tunnel information to create and provision a pseudowire class that describes the
pseudowire connection between two N-PEs. This pseudowire class can be shared by more than one
pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
During service request creation, ISC does not check the validity of the tunnel ID number. That is,
ISC does not verify the existence of the tunnel.
•
The Interface Tunnel attribute is not supported for IOS XR devices.
•
Step 31
Check the AutoPick Bridge Group Name check box to have ISC autopick the bridge group name during
service request creation.
If this check box is unchecked, you are prompted to specify a bridge group name during service request
creation (see the next step).
Usage notes:
Step 32
•
This attribute only displays for IOS XR devices.
•
If the AutoPick Bridge Group Name check box is unchecked, enter an bridge group name in the
Bridge Group Name text field.
•
The AutoPick Bridge Group Name and Bridge Group Name attributes only appear if Configure
Bridge Domain was enabled in the EVC Service Request Editor window earlier in the service
request workflow.
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID during
service request creation.
If this check box is unchecked, you are prompted to specify a VLAN ID during service request creation
(see the next step).
Usage notes:
Step 33
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain VLAN ID is picked from the existing ISC VLAN pool.
•
The AutoPick Bridge Domain/VLAN ID attribute appears for both Cisco 7600 and ASR 9000
devices. It will be displayed only for non-FlexUNI links.
If the AutoPick Bridge Domain/VLAN ID check box is unchecked, enter an ID number in the Bridge
Domain/VLAN ID text field.
Usage notes:
Step 34
•
If AutoPick Bridge Domain/VLAN ID is checked, this field is non-editable.
•
When a VLAN ID is manually allocated, ISC verifies the VLAN ID to see if it lies within ISC’s
VLAN ID pool. If the VLAN ID is in the pool but not allocated, the VLAN ID is allocated to the
service request. If the VLAN ID is in the pool and is already in use, ISC prompts you to allocate a
different VLAN ID. If the VLAN ID lies outside of the ISC VLAN ID pool, ISC does not perform
any verification about whether the VLAN ID allocated. The operator must ensure the VLAN ID is
available.
•
The Bridge Domain/VLAN ID text field appears for both Cisco 7600 and ASR 9000 devices. It will
be displayed only for non-FlexUNI links.
Check the AutoPick Bridge Domain Name check box to have ISC autopick the bridge domain name
during service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-18
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
If this check box is unchecked, you are prompted to specify a bridge domain name during service request
creation (see the next step).
Usage notes:
Step 35
•
The AutoPick Bridge Domain Name attribute appears only for Cisco ASR 9000 devices.
•
The AutoPick Bridge Domain Name attribute only appears if Configure Bridge Domain was enabled
in the EVC Service Request Editor window earlier in the service request workflow.
If the AutoPick Bridge Domain Name check box is unchecked, enter a bridge domain name in the Bridge
Domain Name text field.
Usage notes:
Step 36
•
Bridge Domain Name field appears only for Cisco ASR 9000 devices.
•
The Bridge Domain Name attribute only appears if Configure Bridge Domain was enabled in the
EVC Service Request Editor window earlier in the service request workflow.
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is unchecked by default.
Usage notes:
Step 37
•
The pseudowire class name is used for provisioning pw-class commands on IOS XR devices. See
Creating and Modifying Pseudowire Classes for IOS XR Devices, page 2-10 for additional
information on pseudowire class support for IOS XR devices.
•
If Use PseudoWireClass is checked, an additional attribute, PseudoWireClass, appears in the GUI.
Click the Select button of PseudoWireClass attribute to choose a pseudowire class previously
created in ISC.
•
The Use PseudoWireClass attribute is only available if the MPLS core connectivity type was set as
PSEUDOWIRE in the Service Options window (see Setting the Service Options, page 3-8).
•
Use PseudoWireClass is only applicable for IOS XR devices.
•
The Use PseudoWireClass and PseudoWireClass attributes only appear if Configure Bridge Domain
was not enabled in the EVC Service Request Editor window earlier in the service request workflow.
For L2VPN Group Name choose one of the following from the drop-down list:
•
ISC
•
VPNSC
Usage notes:
•
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 38
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the
drop-down list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
•
The L2VPN Group Name attribute is not available if the MPLS core connectivity type was set as
VPLS in the Service Options window (see Setting the Service Options, page 3-8).
•
L2VPN Group Name is only applicable for IOS XR devices.
•
The L2VPN Group Name attribute only appears if Configure Bridge Domain was not enabled in the
EVC Service Request Editor window earlier in the service request workflow.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-19
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Setting the Service Request Details
Usage notes:
•
If no value is specified for the E-Line Name, ISC autogenerates a default name as follows:
– For PSEUDOWIRE core connectivity type, the format is:
DeviceName--VC_ID
– For LOCAL core connectivity type, the format is:
DeviceName--VLAN_ID
If the default name is more than 32 characters, the device names are truncated.
Step 39
•
The E-Line Name attribute is not available if the MPLS core connectivity type was set as VPLS in
the Service Options window (see Setting the Service Options, page 3-8).
•
E-Line Name is only applicable for IOS XR devices.
•
The E-Line Name attribute only appears if Configure Bridge Domain was not enabled in the EVC
Service Request Editor window earlier in the service request workflow.
Click OK to save the Standard UNI settings and return to the EVC Service Request window.
The value in the Link Attributes column now displays as “Changed,” signifying that the link settings
have been updated. You can edit the link attributes now or at a future time by clicking on the Changed
link and modifying the settings in the Standard UNI Details window.
See Modifying the FlexUNI/EVC Service Request, page 4-21 for details on editing the link attributes.
Step 40
To add another link click the Add button and set the attributes for the new link as in the previous steps
in this section.
Step 41
To delete a link, check the check box in the first column of the row for that link and click the Delete
button.
Step 42
If you want to set up links with L2 access nodes for this service request, see Setting Links with L2 Access
Nodes, page 4-20.
Step 43
When you have completed setting the attributes in the EVC Service Request Editor window, click the
Save button at the bottom of the window to save the settings and create the FlexUNI/EVC service
request.
If any attributes are missing or incorrectly set, ISC displays a warning in the lower left of the window.
Make any corrections or updates needed (based on the information provided by ISC), and click the Save
button.
For information on modifying a FlexUNI/EVC service request see the section Modifying the
FlexUNI/EVC Service Request, page 4-21. For additional information about saving a FlexUNI/EVC
service request, see Saving the FlexUNI/EVC Service Request, page 4-23.
Setting Links with L2 Access Nodes
The Links with L2 Access Nodes section of the EVC Service Request Editor window allows you to set
up links with L2 (Ethernet) access nodes. These are similar to direct connect links, except that they have
L2/Ethernet access nodes beyond the N-PE (towards the CE). Therefore, NPCs are involved. The steps
for setting up links with L2 access nodes are similar to those covered in the section Setting Direct
Connect Links, page 4-10. See that section for detailed steps on the following common operations:
•
Adding and deleting links.
•
Selecting the N-PE.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-20
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Modifying the FlexUNI/EVC Service Request
•
Choosing the UNI interface.
•
Setting the link as a FlexUNI link.
•
Editing the standard and FlexUNI link attributes.
The main difference in setting up links with L2 access does is specifying the NPC details.
Perform the following steps to set the NPC details for links with L2 access nodes:
Step 1
The first step in the process of adding a link using NPCs is selecting the U-PE/PE-AGG device, rather
than the N-PE.
If only one NPC exists for the chosen interface, that NPC is autopopulated in the Circuit Details column,
and you need not choose it explicitly.
If more then one NPC is available, click Select one circuit in the Circuit Selection column. The NPC
window appears, enabling you to choose the appropriate NPC.
Step 2
Click OK.
Each time you choose a PE and its interface, the NPC that was set up from this PE and interface is
automatically displayed under Circuit Selection. This means that you do not have to further specify the
PE to complete the link.
If you want to review the details of this NPC, click Circuit Details in the Circuit Details column. The
NPC Details window appears and lists the circuit details for this NPC.
Step 3
For details about editing link attributes, adding or deleting links, or using the FlexUNI check box, see
the corresponding steps in the section Setting Direct Connect Links, page 4-10.
Step 4
When you have completed setting the attributes in the EVC Service Request Editor window, click the
Save button at the bottom of the window to save the settings and create the FlexUNI/EVC service
request.
If any attributes are missing or incorrectly set, ISC displays a warning in the lower left of the window.
Make any corrections or updates needed (based on the information provided by ISC), and click the Save
button.
For information on modifying a FlexUNI/EVC service request see the section Modifying the
FlexUNI/EVC Service Request, page 4-21. For additional information about saving a FlexUNI/EVC
service request, see Saving the FlexUNI/EVC Service Request, page 4-23.
Modifying the FlexUNI/EVC Service Request
You can modify a FlexUNI/EVC service request if you must change or modify the links or other settings
of the service request.
To modify a FlexUNI/EVC service request, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears, showing service request available in ISC.
Step 2
Check a check box for a service request.
Step 3
Click Edit.
EVC Service Editor window appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-21
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Using Templates and Data Files with a FlexUNI/EVC Ethernet Service Request
Step 4
Modify any of the attributes, as desired.
See the sections start with “Setting the Service Request Details” section on page 4-2 for detailed
coverage of setting attributes in this window.
Note
Once the VC ID, VPLS VPN ID, and VLAN ID have been set in a service request they cannot
be modified.
Step 5
To add a template/data file to an attachment circuit, see the section Using Templates and Data Files with
a FlexUNI/EVC Ethernet Service Request, page 4-22.
Step 6
When you are finished editing the FlexUNI/EVC service request, click Save.
For additional information about saving a FlexUNI/EVC service request, see Saving the FlexUNI/EVC
Service Request, page 4-23.
Using Templates and Data Files with a FlexUNI/EVC Ethernet
Service Request
ISC does not support configuration of all the available CLI commands on a device being managed by the
application. In order to configure such commands on the devices, you can use ISC Template Manager
functionality. Templates can be associated at the policy level on a per-device role basis. Templates can
be overridden at service request level, if the policy-level setting permits the operator to do so.
To associate templates and data files in a service request select any link in the Service Request Editor
window and click the Template button at the bottom of the window.
Note
If the template feature has not been enabled in the associated policy then the Template button will not
be available for selection.
The SR Template Association window appears, as shown in Figure 4-8. In this window, you can
associate templates at a per-device level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-22
OL-21636-01
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Saving the FlexUNI/EVC Service Request
Figure 4-8
Sample Templates Association Window
As shown in Figure 4-8, the Template Association window lists the devices comprising the link, the
device roles, and the template(s)/data file(s) associated with the devices. In this case, the
template(s)/data file(s) have not yet been set up.
For further instructions on how to associate templates and data files with a service request, see
Appendix B, “Working with Templates and Data Files,” especially the section Using Templates with
Service Requests, page B-10.
Saving the FlexUNI/EVC Service Request
To save a FlexUNI/EVC Ethernet service request, perform the following steps.
Step 1
When you have finished setting the attributes for the FlexUNI/EVC Ethernet service request, click Save
to create the service request.
If the FlexUNI/EVC service request is successfully created, you will see the service request list window,
similar to what appears in Figure 4-9.
Figure 4-9
FlexUNI/EVC Service Request Created
The newly created FlexUNI/EVC Ethernet service request is added with the state of REQUESTED, as
shown in the figure.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
4-23
Chapter 4
Managing a FlexUNI/EVC Ethernet Service Request
Saving the FlexUNI/EVC Service Request
Step 2
If, however, the FlexUNI Ethernet service request creation failed for some reason (for example, a value
chosen is out of bounds), you are warned with an error message.
In such a case, you should correct the error and save the service request again.
Step 3
If you are ready to deploy the FlexUNI/EVC Ethernet service request, see Deploying Service Requests,
page 11-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
4-24
OL-21636-01
CH A P T E R
5
Creating a FlexUNI/EVC ATM-Ethernet
Interworking Policy
This chapter contains an overview of FlexUNI/EVC ATM-Ethernet Interworking support in ISC, as well
as the basic steps to create a FlexUNI/EVC ATM-Ethernet Interworking policy. It contains the following
sections:
•
Overview, page 5-1
•
Defining the FlexUNI/EVC ATM-Ethernet Interworking Policy, page 5-2
•
Setting the Service Options, page 5-4
•
Setting the ATM Interface Attributes, page 5-6
•
Setting the FlexUNI Attributes, page 5-7
•
Setting the Interface Attributes, page 5-12
•
Enabling Template Association, page 5-19
For information on creating FlexUNI/EVC ATM-Ethernet service requests, see Chapter 6, “Managing a
FlexUNI/EVC ATM-Ethernet Interworking Service Request.”
Note
For a general overview of FlexUNI/EVC support in ISC (not restricted to ATM-Ethernet Interworking),
see Overview of FlexUNI/EVC Support in ISC, page 3-1.
Overview
ISC supports interworking of a service with ATM and Ethernet protocols across the MPLS core or local
switching. ATM-Ethernet interworking is supported through the following features:
•
Creation of a FlexUNI/EVC policy of type “ATM-Ethernet Interworking.” The ATM-Ethernet
Interworking policy type supports a choice of MPLS core options:
– Pseudowire
– Local (local connects)
•
Provisioning of ATM-Ethernet interworking using a single FlexUNI/EVC service request.
•
Combination of EVC and non-EVC syntax, that is, the creation of an L2 circuit consisting of an L2
syntax and EVC syntax.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-1
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Defining the FlexUNI/EVC ATM-Ethernet Interworking Policy
•
Supported platforms:
– ATM interworking is supported on the Cisco 7600 with ES-20 cards.
– ASR 9000 device is supported for IOS XR 3.7.3 and IOS XR 3.9. Because there are no ATM
interfaces on the Cisco ASR 9000, ISC does not support interworking on the ASR 9000 for
ATM interfaces. Only Ethernet interfaces are supported.
Defining the FlexUNI/EVC ATM-Ethernet Interworking Policy
You must define a FlexUNI/EVC ATM-Ethernet Interworking policy before you can provision a service.
A policy can be shared by one or more service requests that have similar service requirements.
A policy is a template of most of the parameters needed to define a FlexUNI/EVC service request. After
you define it, a FlexUNI/EVC policy can be used by all the FlexUNI/EVC service requests that share a
common set of characteristics. You create a new FlexUNI/EVC policy whenever you create a new type
of service or a service with different parameters. FlexUNI/EVC policy creation is normally performed
by experienced network engineers.
The Editable check box for an attribute in the policy gives the network operator the option of making a
field editable. If the value is set to editable, the service request creator can change the value(s) of the
particular policy attribute. If the value is not set to editable, the service request creator cannot change
the attribute.
You can also associate Cisco IP Solution Center (ISC) templates and data files with a service request.
See Appendix B, “Working with Templates and Data Files,” for more about using templates and data
files in service requests.
To define a FlexUNI/EVC ATM-Ethernet Interworking policy, you start by setting the service type
attributes. To do this, perform the following steps.
Step 1
Choose Service Design > Policies.
The Policies window appears.
Step 2
Click Create.
Step 3
Choose FlexUNI (EVC) Policy.
The EVC Policy Editor - Service Type window appears, as shown in Figure 5-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-2
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Defining the FlexUNI/EVC ATM-Ethernet Interworking Policy
Figure 5-1
EVC Policy Editor - Service Type
Step 4
Enter a Policy Name for the FlexUNI/EVC ATM-Ethernet Interworking policy.
Step 5
Choose the Policy Owner for the FlexUNI/EVC policy.
There are three types of FlexUNI/EVC policy ownership:
•
Customer ownership
•
Provider ownership
•
Global ownership—Any service operator can make use of this policy.
This ownership has relevance when the ISC Role-Based Access Control (RBAC) comes into play. For
example, a FlexUNI/EVC policy that is customer-owned can only be seen by operators who are allowed
to work on this customer-owned policy. Similarly, operators who are allowed to work on a provider’s
network can view, use, and deploy a particular provider-owned policy.
Step 6
Click Select to choose the owner of the FlexUNI/EVC policy.
The policy owner was established when you created customers or providers during ISC setup. If the
ownership is global, the Select function does not appear.
Step 7
Choose the Policy Type.
The choices are:
Note
Step 8
•
ETHERNET
•
ATM-Ethernet Interworking
This chapter describes creating the ATM-Ethernet Interworking policy type. For information on using
the FlexUNI/EVC ETHERNET policy type, see Chapter 3, “Creating a FlexUNI/EVC Ethernet Policy.”
Click Next.
The EVC Policy Editor - Service Options window appears, as show in Figure 5-2.
Step 9
Continue with the steps contained in the next section, Setting the Service Options, page 5-4.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-3
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Service Options
Setting the Service Options
This section describes how to set the service options for the FlexUNI/EVC policy, as shown in
Figure 5-2.
Figure 5-2
EVC Policy Editor - Service Options Window
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this FlexUNI/EVC policy can modify the editable parameter
during FlexUNI/EVC service request creation.
To set the FlexUNI/EVC service options, perform the following steps.
Step 1
Check the CE Directly Connected to FlexUNI check box if the CEs are directly connected to the N-PE.
This check box is not checked by default.
Usage notes:
Step 2
•
If the check box is checked, a service request created using this policy can have only directly
connected links. No Ethernet access nodes will be involved.
•
If the check box is unchecked, a service request created using this policy might or might not have
Ethernet access nodes in the links.
•
When a CE is directly connected to the N-PE, NPCs are not applicable to the link while creating
service requests.
•
When a CE is not directly connected to the N-PE, NPCs are used during service request creation, as
per standard ISC behavior. There is no change in NPC implementation to support FlexUNI/EVC
functionality.
Check the All Links Terminate on FlexUNI check box if all links need to be configured with
FlexUNI/EVC features.
This check box is not check by default. Usage notes:
•
If the check box is checked, a service request created using such policy will have all links using the
FlexUNI/EVC feature.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-4
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Service Options
•
If the check box is unchecked, zero or more links can use the FlexUNI/EVC feature. This ensures
that existing platforms can still be used in one or more links while delivering the services. This
allows the possibility of a link with FlexUNI/EVC support being added in the future.
Note
•
Step 3
Note
If the check box is unchecked, in the service request creation process the user must indicate
whether or not the created link is FlexUNI or non-FlexUNI.
If no links are expected to use the FlexUNI/EVC feature even in the future (for example, if the
provider is not planning to upgrade to the EVC infrastructure for the service that is being created),
existing ISC policy types (L2VPN or VPLS) can be used instead of FlexUNI/EVC.
Choose an MPLS Core Connectivity Type from the drop-down list.
The core option supports MPLS only. There is no L2TPv3 support for this service.
The choices are:
•
PSEUDOWIRE—Choose this option to allow connectivity between two N-PEs across the MPLS
core. This option does not limit the service to point-to-point (E-Line). This is because even with the
PSEUDOWIRE option selected, there can still be multiple CEs connected to a bridge domain on one
or both sides of the pseudowire.
•
LOCAL—Choose this option for local connect cases in which there is no connectivity required
across the MPLS core.
Local connect supports the following scenarios:
– All interfaces on the N-PE are FlexUNI-capable and using the EVC infrastructure. This is
configured by associating all of the customer traffic on these interfaces to a bridge domain. This
consumes a VLAN ID on the N-PE (equal to the bridge domain ID).
– Some interfaces on the N-PE are FlexUNI-capable, while others are switch-port-based. In such
cases, all of the customer traffic on the interfaces that are configured with the EVC
infrastructure are associated to a bridge domain. The traffic on the non-FlexUNI interfaces (and
all the access nodes/interfaces beyond this N-PE) are configured with the Service Provider
VLAN ID, where the Service Provider VLAN ID is the same as the bridge domain ID for the
EVC-based services.
– Only two interfaces on the N-PE are involved, and both are based on FlexUNI-capable line
cards. In the first case, the operator might choose not to configure the bridge domain option. In
this case, the connect command that is used for the local connects are used, and the global
VLAN is conserved on the device. If the operator chooses to configure with the bridge domain
option, both interfaces are associated to a bridge domain ID, so that additional local links can
be added to the service in future. This consumes a VLAN ID (bridge domain ID) on the N-PE.
•
Note
VPLS—This option is not supported for FlexUNI/EVC ATM-Ethernet Interworking policies and
services requests.
Attributes available in subsequent windows of the policy workflow dynamically change based on the
choice made for the MPLS Core Connectivity Type (PSEUDOWIRE or LOCAL). For completeness, all
attributes available for the different core types are documented in the following steps. Attributes apply
to all core types, unless otherwise noted.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-5
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the ATM Interface Attributes
Note
Step 4
Also, some attributes are supported only on IOS or IOS XR platforms. Attributes apply to both
platforms, unless otherwise noted. All platform-specific attributes are visible in the policy workflow
windows. Later, when a service request is created based on the policy (and specific devices are
associated with the service request), platform-specific attributes are filtered from service request
windows, depending on the device type (IOS or IOS XR).
Check the Configure With Bridge Domain check box to determine bridge domain characteristics.
The behavior of the Configure With Bridge-Domain option works in tandem with the choice you selected
in the MPLS Core Connectivity Type option, as follows.
•
PSEUDOWIRE as the MPLS Core Connectivity Type. There are two cases:
A. With FlexUNI:
– If Configure With Bridge Domain is checked, the policy configures pseudowires under SVIs
associated to the bridge domain.
– If Configure With Bridge Domain is unchecked, the policy will configure pseudowires
directly under the service instance. This conserves the global VLAN.
B. Without FlexUNI:
– If Configure With Bridge Domain is checked, the policy configures pseudowires as in L2VPN
services (with SVIs).
– If Configure With Bridge Domain is unchecked, the policy configures pseudowires directly
under subinterfaces.
Only pseudowires can be either configured directly under service instance of the corresponding
FlexUNI-capable interface or under SVIs associated to the bridge domain.
•
LOCAL as the MPLS Core Connectivity Type:
– If Configure With Bridge Domain is checked, the policy allows either point-to-point or
multipoint local connect services.
– If Configure With Bridge Domain is unchecked, ISC allows only point-to-point local connects
without bridge domain.
Step 5
Click Next.
The EVC Policy Editor - ATM Interface Attribute window appears, as shown in Figure 5-3.
Step 6
Continue with the steps contained in the next section, Setting the ATM Interface Attributes, page 5-6.
Setting the ATM Interface Attributes
This section describes how to set the ATM Interface attributes for the FlexUNI/EVC ATM-Ethernet
Interworking policy, as shown in Figure 5-3.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-6
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the FlexUNI Attributes
Figure 5-3
EVC Policy Editor - ATM Interface Attributes Window
To set the ATM interface attributes, perform the following steps.
Step 7
Choose the Transport Mode from the drop-down list.
The choices are:
Step 8
•
VP—Virtual path mode. This is the default.
•
VC—Virtual circuit mode.
Choose the ATM Encapsulation from the drop-down list.
•
Step 9
AAL5SNAP
Click Next.
The EVC Policy Editor - FlexUNI Attribute window appears, as shown in Figure 5-4.
Step 10
Continue with the steps contained in the next section, Setting the FlexUNI Attributes, page 5-7.
Setting the FlexUNI Attributes
This section describes how to set the FlexUNI attributes for the FlexUNI/EVC ATM-Ethernet
Interworking policy, as shown in Figure 5-4.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-7
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the FlexUNI Attributes
Figure 5-4
EVC Policy Editor - FlexUNI Attribute Window
FlexUNI attributes are organized under the following categories:
•
Service Attributes
•
VLAN Match Criteria
•
VLAN Rewrite Criteria
The following sections describe how to set the options under each category.
Setting the Service Attributes
To set the FlexUNI service attributes, perform the following steps.
Step 1
Check the AutoPick Service Instance ID check box to specify that the service instance ID will be
autogenerated and allocated to the link during service request creation.
If the check box is unchecked, while setting the ISC link attributes during service request creation, ISC
will prompt the operator to specify the service instance ID.
Usage notes:
•
The service instance ID represents an Ethernet Flow Point (EFP) on an interface in the EVC
infrastructure. The service instance ID is locally significant to the interface. This ID has to be unique
only at the interface level. The ID must be a value from 1 to 8000.
•
There are no resource pools available in ISC from which to allocate the service instance IDs.
•
It is the responsibility of the operator creating the service request to maintain the uniqueness of the
ID at the interface level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-8
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the FlexUNI Attributes
Step 2
Check the AutoPick Service Instance Name check box to have ISC autogenerate a service instance
name when you create a service request based on the policy. The autogenerated value is in the following
pattern: CustomerName_ServiceRequestJobID.
If the check box is unchecked, then you can enter a value during service request creation.
Step 3
Check the Enable PseudoWire Redundancy check box to enable pseudowire redundancy (alternative
termination device) under certain conditions.
Usage notes:
•
Step 4
Enable Pseudo Wire Redundancy is only available if the MPLS Core Connectivity Type was set as
PSEUDOWIRE in the Service Options window (see Setting the Service Options, page 5-4).
Check the AutoPick VC ID check box to have ISC autopick the VC ID during service request creation.
If this check box is unchecked, the operator will be prompted to specify a VC ID during service request
creation.
Usage notes:
•
Step 5
When AutoPick VC ID is checked, ISC allocates a VC ID for pseudowires from the ISC-managed
VC ID resource pool.
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID for the
service request during service request creation.
If this check box is unchecked, the operator will be prompted to specify a VLAN ID during service
request creation.
Usage notes:
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain/VLAN ID is picked from the existing ISC VLAN pool. Once the VLAN ID is
assigned in the service request, ISC makes the VLAN ID unavailable for subsequent service
requests.
•
In the case of manual VLAN ID allocation, ISC does not manage the VLAN ID if the ID lies outside
the range of an ISC-managed VLAN pool. In this case, the operator must ensure the uniqueness of
the ID in the Ethernet access domain. If an operator specifies a VLAN ID that is within the range of
an ISC-managed VLAN pool and the VLAN ID is already in use in the access domain, ISC displays
an error message indicating that the VLAN ID is in use.
Note on Access VLAN IDs
An access VLAN ID is of local significance to the FlexUNI-capable ports. It should not be confused with
the global VLANs. This can be visualized as a partitioning of the Ethernet access network beyond the
FlexUNI ports into several subEthernet access domains (one each for a FlexUNI-capable port).
However, all the service interfaces on the Ethernet access nodes beyond the FlexUNI ports will have this
very same VLAN ID for a link. This ID must be manually specified by the operator when setting the link
attributes during service request creation. The operator must ensure the uniqueness of the ID across the
FlexUNI-demarcated Ethernet access domain.
These VLAN IDs are not managed by ISC by means of locally-significant VLAN pools. But once a
VLAN ID is assigned for a link in the service request, ISC makes the VLAN unavailable for subsequent
service requests within the Ethernet access domain demarcated by the FlexUNI. Likewise, if a
manually-specified VLAN is already in use in the access domain delimited by the FlexUNI, ISC will
display an error message indicating that the new VLAN ID being specified is already in use on the NPC.
The operator will be prompted to specify a different VLAN ID, which will be provisioned on the L2
access nodes.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-9
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the FlexUNI Attributes
Step 6
Continue with the steps contained in the next section, Setting the VLAN Matching Criteria Attributes,
page 5-10.
Setting the VLAN Matching Criteria Attributes
Prior to the introduction of the FlexUNI capability, service providers could either deploy
service-multiplexed services (ERS/ERMS or EVPL/EVCS) or service-bundled services on a single port.
Both could not be supported simultaneously due to the limitations in the infrastructure, which only
allowed matching the outer-most VLAN tag.
One of the key benefits of FlexUNI/EVC support in ISC is to provide a flexible means to examine the
VLAN tags (up to two levels) of the incoming frames and associate them to appropriate Ethernet Flow
Points (EFPs). This allows service providers to deploy simultaneously both the service-multiplexed and
service-bundled services on a single port.
To set the FlexUNI VLAN matching criteria attributes, perform the following steps.
Step 1
Check the Both Tags check box to enable service requests created with the policy to match both the inner
and outer VLAN tags of the incoming frames.
If you do not check this check box, service requests created with the policy will match only the outer
VLAN tag of the incoming frames.
Checking the Both Tags attribute causes the Inner VLAN Ranges attribute (covered in the next steps) to
appear in the FlexUNI Attribute window.
Step 2
Check the Inner VLAN Ranges check box to enable the range of inner VLAN tags to be specified
during service request creation.
If the check box is unchecked, the range of inner VLAN tags are not allowed. In this case, the operator
must specify discrete VLAN IDs during service request creation.
Step 3
Continue with the steps contained in the next section, Setting the VLAN Rewrite Criteria Attributes,
page 5-10.
Setting the VLAN Rewrite Criteria Attributes
Together with VLAN matching criteria, VLAN rewrite makes the FlexUNI/EVC infrastructure very
powerful and flexible. The following VLAN rewrite options are supported:
•
Pop one or two tags.
•
Push one or two tags.
•
Translation (1:1, 2:1, 1:2, 2:2).
Be aware of the following considerations when setting the VLAN rewrite criteria attributes:
•
Only one kind of rewrite can be done on every CE-facing FlexUNI link.
•
All VLAN rewrites are done using the symmetric keyword on the ingress traffic (for example,
rewrite ingress tag pop 2 symmetric).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-10
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the FlexUNI Attributes
•
For any service instance, only one type of rewrite option (pop, push, or translate) is allowed per
instance. For example, if pop out is enabled, push inner, push outer, translate inner, and translate
outer are not available.
To set the FlexUNI VLAN rewrite criteria attributes, perform the following steps.
Step 1
Check the Pop Outer check box to pop the outer VLAN ID tag of the incoming frames that fulfill the
match criteria.
If this check box is unchecked, the outer tag of the incoming traffic is not popped.
Step 2
Check the Pop Inner check box to pop the inner VLAN ID tag of the incoming frames that fulfill the
match-criteria.
If this check box is unchecked, the inner tag is not popped. Note that, if Pop Inner is checked, Pop Outer
is automatically checked.
Step 3
Check the Push Outer check box to impose an outer VLAN ID tag onto the incoming frames that fulfill
the match criteria.
If this check box is unchecked, no outer tag is imposed on the incoming frames.
Usage notes:
Step 4
•
If Push Outer is checked, all service requests created with the policy push a dot1q outer tag on the
incoming frames matching the match criteria. When creating the link during service creation, the
operator can specify an outer tag with a value from 1 to 4096.
•
This attribute is available regardless of the number of tags used in the match criteria. Whether the
incoming traffic is double tagged or single tagged, if Push Outer is enabled, all corresponding
service requests push an outer tag. All subsequent nodes consider only the outer-most two tags (if
FlexUNI-capable) or just one tag (not FlexUNI-capable) and treat the inner-most tags transparently
as payload.
•
This VLAN ID is not derived from ISC-managed VLAN ID pools.
Check the Push Inner check box to impose an inner VLAN ID tag onto the incoming frames that fulfill
the match criteria.
This operation pushes both an inner and an outer tag onto the incoming packet, not just an inner tag. If
this check box is unchecked, no inner tag is imposed on the incoming frames.
Usage notes:
Step 5
•
If Push Inner is checked, all service requests created with the policy push a dot1q inner tag on the
incoming frames matching the match criteria. When creating the link during service creation, the
operator can specify an inner tag with a value from 1 to 4096.
•
If Push Inner is checked, Push Outer is automatically checked.
•
This attribute is available regardless of the number of tags used in the match criteria. Regardless of
whether the incoming traffic is double tagged or single tagged, if Push Inner is enabled, all
corresponding service requests push an inner tag. All subsequent nodes consider only the outer-most
two tags (if FlexUNI-capable) or just one tag (not FlexUNI-capable) and treat the inner-most tags
transparently as payload.
•
This VLAN ID is not derived from ISC-managed VLAN ID pools.
Check the Translate Outer check box to allow the operator to specify a target outer VLAN ID during
service request creation.
The outer tag of all the incoming frames that fulfill the match criteria are translated to this ID. If the
check box is unchecked, no outer tag translation is performed. See Table 5-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-11
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
Step 6
Check the Translate Inner check box to allow the operator to specify a target inner VLAN ID during
service request creation.
The inner tag of all the incoming frames that fulfill the match criteria are translated to this ID. If the
check box is unchecked, no inner tag translation is performed. See Table 5-1.
Note
Table 5-1 summarizes the realization of different VLAN translations available in the FlexUNI/EVC
infrastructure. The second and third columns (Match Outer Tag and Match Inner Tag) refer to policy
settings. The last two columns (Translate Outer Tag and Translate Inner Tag) indicate the VLAN
translation that occurs on the incoming frames.
Table 5-1
Step 7
VLAN Translation Summary Table
Type
Match Outer Tag
Match Inner Tag
Translate Outer Tag
Translate Inner Tag
1:1
True
N/A
Yes
No
1:2
True
N/A
Yes
Yes
2:1
True
True
Yes
No
2:2
True
True
Yes
Yes
Click Next.
The EVC Policy Editor - Interface Attribute window appears, as shown in Figure 5-4.
Step 8
Continue with the steps contained in the next section, Setting the Interface Attributes, page 5-12.
Setting the Interface Attributes
This step of creating the FlexUNI/EVC ATM-Ethernet Interworking policy involves setting the interface
attributes, as shown in the EVC Policy Editor - Interface Attribute window in Figure 5-5. The attributes
you can configure in this window are grouped under the following categories:
•
N-PE/U-PE information
•
Speed and duplex information
•
ACL name and MAC addresses
•
UNI port security
•
Storm control
•
L2 protocol tunneling
In some cases, checking an attribute causes additional attributes to appear in the GUI. This is covered in
the steps that follow.
Note
If the CE is directly connected to an N-PE, only speed, duplex, UNI shutdown, and other generic options
are presented. In this case, port security, storm control, L2 protocol tunneling, and other advanced
features are not supported due to the current platform limitations. If these features are needed for a
service, the service provider must deploy Layer 2 Ethernet access nodes beyond the FlexUNI to support
these requirements.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-12
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
Note
Attributes available in the Interface Attributes window dynamically change based on the choice made
for the MPLS Core Connectivity Type (PSEUDOWIRE or LOCAL) in the Service Options window (see
Setting the Service Options, page 5-4). For completeness, all attributes available for the different core
types are documented in the following steps. Attributes apply to all core types, unless otherwise noted.
Figure 5-5
EVC Policy Editor - Interface Attributes Window
To set the FlexUNI/EVC interface attributes, perform the following steps.
Step 1
Choose an Encapsulation type.
The choices are:
Step 2
•
DOT1QTRUNK—Configures the UNI as a trunk with 802.1q encapsulation. If the UNI belongs to
a directly connected and FlexUNI link, this setting signifies that the incoming frames are 802.1q
encapsulated and that they match the VLAN ID configured for the link. This specific topology does
not involve a trunk UNI as such.
•
DOT1QTUNNEL—Configures the UNI as an 802.1q tunnel (also known as a dot1q tunnel or
Q-in-Q) port.
•
ACCESS—Configures the UNI as an access port.
Check the Standard UNI Port check box to enable port security.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-13
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Note
When the UNI is configured on an N-PE device running IOS XR, the Standard UNI Port attribute is not
supported. All the CLIs related to Standard UNI Port and UNI Port Security are ignored in this case.
Step 3
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 4
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable, in order to support modification on a per-service request basis.
Step 5
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 6
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 7
Check the Use Existing ACL Name check box if you want to assign your own named access list to the
port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 8
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
Step 9
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 10
Check the UNI Port Security check box (see Figure 5-6) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-14
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 5-6
Step 11
UNI Port Security
Check the Enable Storm Control check box (see Figure 5-7) to help prevent the UNI port from being
disrupted by a broadcast, multicast, or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 5-7
Step 12
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 5-8) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 5-8
Protocol Tunnelling
For each protocol that you choose, enter the shutdown threshold and drop threshold for that protocol:
a.
Enable cdp—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-15
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
Step 13
b.
cdp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Enable vtp—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
vtp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Enable stp—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
stp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Check the N-PE Pseudo-wire on SVI check box to have ISC generate forwarding commands under SVIs
(switch virtual interfaces).
By default, this check box is not checked. In this case, ISC generates forwarding commands under the
service instance.
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (this is available in the policy workflow in the EVC Policy Editor Service Options window). N-PE Pseudo-wire on SVI, if enabled, will be reflected only when Configure
with Bridge Domain is set to true. Otherwise, the service request will not be created with xconnect under
SVI, even if N-PE Pseudo-wire on SVI is enabled.
Usage notes:
•
ISC supports a hybrid configuration for FlexUNI/EVC service requests. In a hybrid configuration,
the forwarding commands (such as xconnect) for one side of an attachment circuit can be configured
under a service instance, and the xconnect configuration for the other side of the attachment circuit
can be configured under a switch virtual interface (SVI).
•
For examples of these cases, see configlet examples FlexUNI/EVC (Pseudowire Core Connectivity,
Bridge Domain, Pseudowire on SVI), page A-39 and FlexUNI/EVC (Pseudowire Core Connectivity,
no Bridge Domain, no Pseudowire on SVI), page A-40.
•
N-PE Pseudo-wire on SVI is applicable for all connectivity types, but a hybrid SVI configuration is
possible only for pseudowire connectivity.
•
When MPLS Core Connectivity Type is set as LOCAL connectivity type, the N-PE Pseudo-wire on
SVI attribute is always disabled in the policy and service request.
•
The N-PE Pseudo-wire on SVI attribute is not supported for IOS XR devices. All the xconnect
commands are configured on L2 subinterfaces/service instance.
•
Table 5-2 shows various use cases for hybrid configuration for FlexUNI/EVC service requests.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-16
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
Table 5-2
Use Bridge
Domain
FlexUNI
N-PE
Pseudowire
on SVI
True
True
True
True
False
Step 14
Use Cases for Hybrid Configuration for FlexUNI /EVC Service Requests
True
True
False
N/A
CLIs Generated
•
xconnect under VLAN interface.
•
Service instance under main interface.
•
xconnect under service instance.
•
Service instance under main interface.
•
xconnect under service instance.
•
Service instance under main interface.
True
False
True
xconnect under VLAN interface.
True
False
False
xconnect under subinterface.
False
False
False
xconnect under subinterface.
Specify the type of VLAN Translation for this policy by clicking the appropriate radio button.
The choices are:
Step 15
•
No—No VLAN translation is performed. (This is the default.)
•
1:1—1:1 VLAN translation.
•
2:1—2:1 VLAN translation.
Note
For detailed coverage of setting up VLAN translation, see Appendix C, “Setting Up VLAN
Translation.”
Note
VLAN translation is only supported on links that are specified as non-FlexUNI at the service
request level.
Enter the MTU Size in bytes.
The maximum transmission unit (MTU) size is configurable and optional. The default size is 9216, and
the range is 1500 to 9216. ISC does not perform an integrity check for this customized value. If a service
request goes to the Failed Deploy state because this size is not accepted, you must adjust the size until
the Service Request is deployed.
In ISC 6.0, different platforms support different ranges.
Step 16
•
For the 3750 and 3550 platforms, the MTU range is 1500 to 1546.
•
For the Cisco 7600 Ethernet port, the MTU size is always 9216. Even with the same platform and
same IOS release, different line cards support the MTU differently. For example, older line cards
only take an MTU size of 9216 and newer cards support 1500 to 9216. However, ISC 6.0 uses 9216
in both cases.
•
For the Cisco 7600 SVI (interface VLAN), the MTU size is 1500 to 9216.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-17
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Setting the Interface Attributes
This attribute is unchecked by default.
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Step 17
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is unchecked by default.
Usage notes:
Step 18
•
The pseudowire class name is used for provisioning pw-class commands on IOS XR devices. See
Creating and Modifying Pseudowire Classes for IOS XR Devices, page 2-10 for additional
information on pseudowire class support for IOS XR devices.
•
If Use PseudoWireClass is checked, an additional attribute, PseudoWireClass, appears in the GUI.
Click the Select button of PseudoWireClass attribute to choose a pseudowire class previously
created in ISC.
•
The Use PseudoWireClass attribute is only available if the MPLS core connectivity type was set as
PSEUDOWIRE in the Service Options window (see Setting the Service Options, page 5-4).
•
Use PseudoWireClass is only applicable for IOS XR devices.
For L2VPN Group Name choose one of the following from the drop-down list:
•
ISC
•
VPNSC
Usage notes:
•
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
•
Step 19
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the
drop-down list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
L2VPN Group Name is only applicable for IOS XR devices.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
Usage notes:
•
If no value is specified for the E-Line Name in either the policy or the service request based on the
policy, ISC autogenerates a default name as follows:
– For PSEUDOWIRE core connectivity type, the format is:
DeviceName--VC_ID
– For LOCAL core connectivity type, the format is:
DeviceName--VLAN_ID
If the default name is more than 32 characters, the device names are truncated.
•
Step 20
E-Line Name is only applicable for IOS XR devices.
If you want to enable template association for this policy, click the Next button.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-18
OL-21636-01
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Enabling Template Association
See the section Enabling Template Association, page 5-19 for information about this feature.
Step 21
To save the FlexUNI/EVC policy, click Finish.
To create a service request based on a FlexUNI/EVC ATM-Ethernet Interworking policy, see Chapter 6,
“Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request.”
Enabling Template Association
The ISC template feature gives you a means to download free-format CLIs to a device. If you enable
templates, you can create templates and data files to download commands that are not currently
supported by ISC.
Step 1
To enable template association for the policy, click the Next button in EVC Policy Editor - Interface
Attribute window (before clicking Finish).
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”.
Step 2
When you have completed setting up templates and data files for the policy, click Finish in the Template
Association window to close it and return to the Policy Editor window.
Step 3
To save the FlexUNI/EVC ATM-Ethernet Interworking policy, click Finish.
To create a service request based on a FlexUNI/EVCATM-Ethernet Interworking policy, see Chapter 6,
“Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request.”
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
5-19
Chapter 5
Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy
Enabling Template Association
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
5-20
OL-21636-01
CH A P T E R
6
Managing a FlexUNI/EVC ATM-Ethernet
Interworking Service Request
This chapter provides information on how to provision a FlexUNI/EVC ATM-Ethernet Interworking
service request. It contains the following sections:
•
Overview, page 6-1
•
Creating a FlexUNI/EVC ATM-Ethernet Interworking Service Request, page 6-2
•
Setting the Service Request Details, page 6-3
•
Modifying the FlexUNI/EVC Service Request, page 6-23
•
Using Templates and Data Files with a FlexUNI/EVC Service Request, page 6-24
•
Saving the FlexUNI/EVC Service Request, page 6-24
Overview
A FlexUNI/EVC ATM-Ethernet Interworking service request allows you to configure interfaces on an
N-PE to support the FlexUNI/EVC features described in Chapter 5, “Creating a FlexUNI/EVC
ATM-Ethernet Interworking Policy.” To create a FlexUNI/EVC ATM-Ethernet Interworking service
request, a FlexUNI/EVC ATM-Ethernet Interworking service policy must already be defined, as
described in Chapter 5, “Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy.” Based on the
predefined FlexUNI/EVC policy, an operator creates a FlexUNI/EVC service request, with or without
modifications to the policy, and deploys the service. One or more templates can also be associated to the
N-PE as part of the service request.
ATM-Ethernet interworking is supported through the following configurations:
•
ATM Transport Mode (VC)
– ATM-Ethernet Pseudowire
– ATM-ATM Local connect
– ATM-Ethernet Local connect
•
ATM Transport Mode (VP)
– ATM-ATM Local connect
The following steps are involved in creating a FlexUNI/EVC ATM-Ethernet Interworking service
request:
•
Choose an existing FlexUNI/EVC ATM-Ethernet Interworking policy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-1
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Creating a FlexUNI/EVC ATM-Ethernet Interworking Service Request
•
Note
Choose a VPN.
When working with VPN objects in the context of FlexUNI/EVC policies and service requests,
only the VPN name and customer attributes are relevant. Other VPN attributes related to MPLS
and VPLS are ignored.
•
Specify a bridge domain configuration (if applicable).
•
Specify a service request description.
•
Specify automatic or manual allocation of the VC ID or VPLS VPN ID.
•
Add direct connect links (if applicable).
•
Add links with L2 access nodes (if applicable).
•
Choose the N-PE and UNI interface for links.
•
For links with L2 access nodes, choose a Named Physical Circuit (NPC) if more than one NPC exists
from the N-PE or the UNI interface.
•
Edit the link attributes.
•
Modify the service request.
•
Save the service request.
Creating a FlexUNI/EVC ATM-Ethernet Interworking Service
Request
To create a FlexUNI/EVC ATM-Ethernet Interworking service request, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears.
Step 2
Click Create.
Step 3
Choose FlexUNI (EVC) from the drop-down list.
The Select EVC Policy window appears. If more than one FlexUNI/EVC policy exists, a list of
FlexUNI/EVC policies appears. FlexUNI/EVC service requests must be associated with a FlexUNI/EVC
policy. You choose a FlexUNI/EVC ATM-Ethernet Interworking policy from the policies previously
created (see Chapter 5, “Creating a FlexUNI/EVC ATM-Ethernet Interworking Policy”).
Step 4
Choose a FlexUNI/EVC ATM-Ethernet Interworking policy from the list.
Step 5
Click OK.
The EVC Service Request Editor window appears. The new service request inherits all the properties of
the chosen FlexUNI/EVC ATM-Ethernet Interworking policy, such as all the editable and non-editable
features and pre-set parameters.
Step 6
Continue with the steps contained in the next section, Setting the Service Request Details, page 6-3.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-2
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Setting the Service Request Details
After you have selected the FlexUNI/EVC policy to be used as the basis of the service request, the EVC
Service Request Editor window appears. It is divided into three main sections:
•
Service Request Details
•
Direct Connect Links (no NPCs)
•
Links with L2 Access Nodes (involves NPCs)
This window enables you to specify options for the service request, as well as configure directly
connected links and links with L2 access nodes. The options displayed in first section of the window
change, depending on the MPLS Core Connectivity Type that was specified in the policy (pseudowire or
local). For clarity, each of these scenarios is presented in a separate section below, to highlight the
different window configurations and behavior of the displayed options.
Proceed to the appropriate section, as determined by the MPLS Core Connectivity Type for the policy:
•
Pseudowire Core Connectivity, page 6-3
•
Local Core Connectivity, page 6-6
Instructions for setting up direct connect links and links with L2 access nodes are presented in later
sections.
Pseudowire Core Connectivity
If the MPLS Core Connectivity Type for the FlexUNI/EVC ATM-Ethernet Interworking policy is
PSEUDOWIRE, the EVC Service Request Editor window shown Figure 6-1 appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-3
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Figure 6-1
EVC Service Request Details Window for Pseudowire Core Connectivity
Perform the following steps to set the attributes in the first section of the Service Request Details
window:
Note
The Job ID and SR ID fields are read-only. When the service request is being created for the first time,
the fields display a value of NEW. When an existing service request is being modified, the values of the
fields indicate the respective IDs that the ISC database holds within the editing flow of the service
request.
Note
The Policy field is read-only. It displays the name of the policy on which the service request is based.
Clicking on the read-only policy name displays a list of all the attribute values set within the policy.
Step 1
Click Select VPN to choose a VPN for use with this service request.
The Select VPN window appears with the VPNs defined in the system.
Note
The same VPN can be used by service requests with LOCAL and PSEUDOWIRE core types. If
a VPN for a service request is used with VPLS core type, the same VPN cannot be used for
service requests with LOCAL or PSEUDOWIRE core type.
Step 2
Choose a VPN Name in the Select column.
Step 3
Click Select.
The EVC Service Request Editor window appears with the VPN name displayed.
Step 4
Check the AutoPick VC ID check box if you want ISC to choose a VC ID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-4
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
If you do not check this check box, you will be prompted to provide the ID in the VC ID field, as covered
in the next step.
When AutoPick VC ID is checked, ISC allocates a VC ID for pseudowires from the ISC-managed VC
ID resource pool. In this case, the text field for the VC ID option is non-editable.
Step 5
If AutoPick VC ID was unchecked, enter a VC ID in the VC ID field.
Usage notes:
Step 6
•
The AutoPick VC ID attribute appears during the creation of a FlexUNI/EVC pseudowire service
request.
•
The VC ID value must be an integer value corresponding to a VC ID.
•
When a VC ID is manually allocated, ISC verifies the VC ID to see if it lies within ISC’s VC ID
pool. If the VC ID is in the pool but not allocated, the VC ID is allocated to the service request. If
the VC ID is in the pool and is already in use, ISC prompts you to allocate a different VC ID. If the
VC ID lies outside of the ISC VC ID pool, ISC does not perform any verification about whether or
not the VC ID allocated. The operator must ensure the VC ID is available.
•
The VC ID can be entered only while creating a service. If you are editing the service request, the
VC ID field is not editable.
Check the Configure Bridge Domain check box to determine bridge domain characteristics.
The behavior of the Configure Bridge Domain option works in tandem with the choice you selected in
the MPLS Core Connectivity Type option in the FlexUNI/EVC policy, which in this case is pseudowire
core connectivity. There are two cases:
•
With FlexUNI:
– If Configure With Bridge Domain is checked, the policy will configure pseudowires under
SVIs associated to the bridge domain.
– If Configure With Bridge Domain is unchecked, the policy will configure pseudowires
directly under the service instance. This will conserve the global VLAN.
•
Without FlexUNI:
– If Configure With Bridge Domain is checked, the policy will configure pseudowires under
SVIs.
– If Configure With Bridge Domain is unchecked, the policy will configure pseudowires
directly under subinterfaces.
Pseudowires can be configured either directly under service instance of the corresponding
FlexUNI-capable interface or under SVIs associated to the bridge domain.
Step 7
Check the Use Split Horizon check box to enable split horizon with bridge domain.
Usage notes:
Step 8
•
The Use Split Horizon attribute is disabled by default.
•
The Use Split Horizon attribute can be used only when the Configure Bridge Domain check box is
checked (enabled).
•
When Use Split Horizon is enabled, the bridge domain command in the CLI will be generated with
split horizon. When it is disabled, the bridge domain command will be generated without split
horizon.
Click the “Click here” link of the Description attribute to enter a description label for the service
request.
This is useful for searching the ISC database for the particular service request.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-5
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
A dialogue appears in which you can enter a description.
Step 9
To set up direct connect links, see the section Setting Direct Connect Links, page 6-8.
Step 10
To set up links with L2 access nodes, see the section Setting Links with L2 Access Nodes, page 6-22.
Local Core Connectivity
If the MPLS Core Connectivity Type for the FlexUNI/EVC ATM-Ethernet Interworking policy is
LOCAL, the EVC Service Request Editor window shown Figure 6-2 appears.
Figure 6-2
EVC Service Request Details Window for Local Core Connectivity
Perform the following steps to set the attributes in the first section of the Service Request Details
window:
Step 1
The Job ID and SR ID fields are read-only.
When the service request is being created for the first time, the fields display a value of NEW. When an
existing service request is being modified, the values of the fields indicate the respective IDs that the ISC
database holds within the editing flow of the service request.
Step 2
The Policy field is read-only.
It displays the name of the policy on which the service request is based.
Step 3
Click Select VPN to choose a VPN for use with this service request.
The Select VPN window appears with the VPNs defined in the system.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-6
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Note
The same VPN can be used by service requests with LOCAL and PSEUDOWIRE core types. If
a VPN for a service request is used with VPLS core type, the same VPN cannot be used for
service requests with LOCAL or PSEUDOWIRE core type.
Step 4
Choose a VPN Name in the Select column.
Step 5
Click Select.
The EVC Service Request Editor window appears with the VPN name displayed.
Step 6
Check the Configure Bridge Domain check box to determine bridge domain characteristics.
Usage notes:
•
If Configure Bridge Domain is checked, all links will have the same bridge domain ID allocated
from the VLAN pool on the N-PE. All non-FlexUNI links will have the Service Provider VLAN as
the bridge domain ID. On the other hand, if no FlexUNI links are added, the Service Provider VLAN
will be allocated first and this will be used as the bridge domain ID when FlexUNI links are added.
•
If Configure Bridge Domain is unchecked, a maximum of two links that terminate on the same N-PE
can be added. (This uses the connect command available in the EVC infrastructure.) This is only
supported for ATM-ATM local connect.
Note
See the following comments for details on how ISC autogenerates the connect name.
Because the device only accepts a maximum of 15 characters for the connect name, the connect
name is generated using the following format:
CustomerNameTruncatedToMaxPossibleCharacters_ServiceRequestJobID
For example, if the customer name is NorthAmericanCustomer and the service request job ID is
56345, the autogenerated connect name would be NorthAmer_56345.
The CLI generated would be:
connect NorthAmer_56345 ATM7/0/5 11 ATM7/0/4 18
In this case, 11 and 18 are service instance VPIs.
•
Step 7
If the policy setting for Configure Bridge Domain is non-editable, the option in the service request
will be read-only.
Check the Use Split Horizon check box to enable split horizon with bridge domain.
Usage notes:
Step 8
•
The Use Split Horizon attribute is disabled by default.
•
The Use Split Horizon attribute can be used only when the Configure Bridge Domain check box is
checked (enabled).
•
When Use Split Horizon is enabled, the bridge domain command in the CLI will be generated with
split horizon. When it is disabled, the bridge domain command will be generated without split
horizon.
Click the “Click here” link of the Description attribute to enter a description label for the service
request.
A dialogue appears in which you can enter a description.
Step 9
To set up direct connect links, see the section Setting Direct Connect Links, page 6-8.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-7
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 10
To set up links with L2 access nodes, see the section Setting Links with L2 Access Nodes, page 6-22.
Setting up Links to the N-PE
The lower two sections of the EVC Service Request Editor window allow you to set up links to the N-PE.
For direct connect links, the CE is directly connected to the N-PE, with no intermediate L2 access nodes.
For links with L2 access nodes, there are intermediate devices present between the CE and NPE
requiring NPCs to be created in ISC.
The Direct Connect Link section of the window is where you set up links that directly connect to the
N-PE. No NPCs are involved. ATM links are supported for direct connect links.
The Links with L2 Access Nodes section is where you set up links with L2 (Ethernet) access nodes.
NPCs are involved.
Note
ATM interfaces cannot be in L2 access nodes.
See the appropriate section, depending on which type of link you are setting up:
Note
•
Setting Direct Connect Links, page 6-8
•
Setting Links with L2 Access Nodes, page 6-22
Many of steps for setting up the two link types are the same. The basic workflow for setting up links, as
well as the attributes to be set, are presented in the following section Setting Direct Connect Links,
page 6-8. Even if you are setting up links with L2 access nodes, it will be helpful to refer to the
information presented in that section, as the section on L2 access nodes only covers the unique steps for
such links.
Setting Direct Connect Links
Perform the following steps to set up the direct connect links. Most of these steps apply to links with L2
access nodes also.
Step 1
Click Add to add a link.
A new numbered row for the link attributes appears.
Step 2
Click Select NPE in N-PE column.
The Select PE Device window appears. This window displays the list of currently defined PEs.
Step 3
a.
The Show PEs with drop-down list shows PEs by Provider, PE Region Name, or by Device Name.
b.
The Find button allows a search for a specific PE or a refresh of the window.
c.
The Rows per page drop-down list allows the user to configure the number of entries displayed on
the screen at one time.
In the Select column, choose the PE device name for the link.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-8
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 4
Click Select.
The EVC Service Request Editor window reappears displaying the name of the selected PE in the NPE
column.
Step 5
Choose the UNI interface from the drop-down list in the UNI column.
Note
ISC only displays the available interfaces for the service, based on the configuration of the underlying
interfaces, existing service requests that might be using the interface, and the customer associated with
the service request. You can click the Details button to display a pop-up window with information on
the available interfaces, such as interface name, customer name, VPN name, job ID, service request ID,
service request type, translation type, and VLAN ID information.
Note
When the UNI is configured on an N-PE device running IOS XR, the Standard UNI Port attribute is not
supported. All the CLIs related to Standard UNI Port and UNI Port Security are ignored in this case.
Step 6
Note
Check the FlexUNI check box to mark the link for configuring service instance for the links.
The FlexUNI check box is mentioned at this stage because the setting of the check box alters the
behavior of the link editing function available in the Link Attributes column. This is covered in the next
steps.
Editing the Link Attributes
The next steps document the use of the Edit link in the Link Attributes column. (In the case where the
link attributes have already been set, this link changes from Edit to Change.) The link editing workflow
changes depending on the status of the FlexUNI check box for the link. If the FlexUNI check box is
checked, the editing workflow involves setting attributes in two windows, for two sets of link attributes:
•
The FlexUNI Details
•
Standard UNI Details
If the FlexUNI check box for the link is not checked, only the Standard UNI Details window is presented.
In the steps that follow, both scenarios covered.
Note
Step 7
If you are setting up and ATM link (by choosing an ATM interface as the UNI on the N-PE device, there
is a different workflow. The check box in the FlexUNI(EVC) column dynamically disappears, and
clicking the Edit link in the link attributes column brings up the ATM-Ethernet Attributes window. For
information on using this window to set up an ATM link, see Setting the ATM Link Attributes,
page 6-18.
Click Edit in the Link Attributes column to specify the UNI attributes.
FlexUNI Details Window
If the FlexUNI check box is checked, the FlexUNI Details window appears, as shown in Figure 6-3.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-9
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Figure 6-3
FlexUNI Details Window
All of the fields in the FlexUNI Details screen are enabled based on the policy settings. For example, if
Both Tags is selected in the policy and is editable, then the Match Inner and Outer Tags check box will
be selected and editable in this window. The behavior is similar for the other attributes in the FlexUNI
Details window
Step 8
Check the AutoPick Service Instance ID check box to specify that the service instance ID will be
autogenerated and allocated to the link during service request creation.
If the check box is unchecked, you must specify the service instance ID (see the next step).
Usage notes:
•
The service instance ID represents an Ethernet Flow Point (EFP) on an interface in the EVC
infrastructure. The service instance ID is locally significant to the interface. This ID has to be unique
only at the interface level. The ID must be a value from 1 to 8000.
•
There are no resource pools available in ISC from which to allocate the service instance IDs.
•
In the case of a manually provided service instance ID, it is the responsibility of the operator to
maintain the uniqueness of the ID at the interface level.
•
This attribute is not displayed for IOS XR devices.
Step 9
If the AutoPick Service Instance ID check box is not checked, enter an appropriate value for the service
instance ID in the Service Instance ID field.
Step 10
Check the AutoPick Service Instance Name check box to specify that the service instance name will
be autogenerated.
If the check box is unchecked, you can specify the service instance name (see the next step).
Usage notes:
•
If the check box is checked, the Service Instance Name text field is disabled.
•
The service instance name is autogenerated in the following pattern:
CustomerName_ServiceRequestJobID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-10
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 11
•
For example configlets, see FlexUNI/EVC (No AutoPick Service Instance Name, No Service
Instance Name), page A-42, FlexUNI/EVC (User-Provided Service Instance Name, Pseudowire
Core Connectivity), page A-43, and FlexUNI/EVC (User-Provided Service Instance Name, Local
Core Connectivity), page A-44.
•
This attribute is not displayed for IOS XR devices.
If the AutoPick Service Instance Name check box is not checked, enter an appropriate value for the
service instance ID in the Service Instance Name field.
Usage notes:
Step 12
•
The text string representing the service instance name must be 40 characters or less and contain no
spaces. Other special characters are allowed.
•
If AutoPick Service Instance Name is unchecked and no service instance name is entered in the text
field, then ISC does not generate the global ethernet evc evcname command in the device
configuration generated by the service request.
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID for the
service request during service request creation.
If this check box is unchecked, the you must specify a bridge domain VLAN ID (see the next step).
Usage notes:
Step 13
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain VLAN ID is picked from the existing ISC VLAN pool.
•
This attribute is not displayed for IOS XR devices.
If the AutoPick Bridge Domain/VLAN ID check box is unchecked, enter an appropriate value in the
Bridge Domain/VLAN ID field.
Note
This configuration applies in conjunction with the Configure Bridge Domain option in the EVC
Service Request Editor window. If the option is not enabled in that window, then AutoPick
Bridge Domain/VLAN ID check box is redundant and not required.
When a VLAN ID is manually allocated, ISC verifies the VLAN ID to see if it lies within ISC’s VLAN
ID pool. If the VLAN ID is in the pool but not allocated, the VLAN ID is allocated to the service request.
If the VLAN ID is in the pool and is already in use, ISC prompts you to allocate a different VLAN ID.
If the VLAN ID lies outside of the ISC VLAN ID pool, ISC does not perform any verification about
whether the VLAN ID allocated. The operator must ensure the VLAN ID is available.
Step 14
Check the Match Inner and Outer Tags check box to enable service requests created with the policy
to match both the inner and outer VLAN tags of the incoming frames.
If you do not check this check box, service requests created with the policy will match only the outer
VLAN tag of the incoming frames.
Checking the Match Inner and Outer Tags attribute causes the Inner VLAN ID and Outer VLAN ID
fields (covered in the next steps) to appear.
Step 15
If the Match Inner and Outer Tags check box is checked, enter the inner and outer VLAN tags in the
Inner VLAN ID and Outer VLAN ID fields.
Usage notes:
•
You can specify single values, single ranges, multiples values, multiple ranges, or combinations of
these. Examples:
– 10
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-11
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
– 10, 15,17
– 10-15
– 10-15,17-20
– 10,20-25
•
Step 16
Note
Step 17
If the Inner VLAN Ranges attribute is set to true in the policy, the Inner VLAN ID field can take a
range of inner VLAN tags.
If the Match Inner and Outer Tags check box is unchecked, enter the outer VLAN tag in the Outer
VLAN ID field.
The VLAN specified in Outer VLAN ID will be provisioned on the rest of the L2 access nodes (if the
link has any), including the customer-facing UNI.
In the VLAN Rewrite section of the window, choose a Rewrite Type from the drop-down list.
The choices are:
•
Pop
•
Push
•
Translate
The subsequent attributes in the GUI change depending on the choice of Rewrite Type, as covered in the
next steps.
Step 18
If Pop is the Rewrite Type, two check boxes appear:
a.
Check the Pop Outer Tag check box to pop the outer VLAN ID tag of the incoming frames that
fulfill the match criteria. If this check box is unchecked, the outer tag of the incoming traffic will
not be popped.
b.
Check the Pop Inner Tag check box to pop the inner VLAN ID tag of the incoming frames that
fulfill the match-criteria. If this check box is unchecked, the inner tag will not be changed.
Note that if Pop Inner Tag is checked, Pop Outer Tag is automatically checked.
Step 19
Step 20
If Push is the Rewrite Type, two text boxes appear:
a.
In the text box Outer VLAN ID, enter an outer VLAN ID tag that will be imposed on the incoming
frames that fulfill the match criteria. All service requests created with this setting push a dot1q outer
tag on the incoming frames matching the match criteria. If a value is not provided, the push
operation is ignored and not configured on the device.
b.
In the text box Inner VLAN ID, enter an inner VLAN ID tag that will be imposed on the incoming
frames that fulfill the match criteria. All service requests created with this setting push a dot1q inner
tag on the incoming frames matching the match criteria. The Inner VLAN tag cannot be pushed
without an Outer VLAN tag. That is, when pushing an Inner VLAN tag, the Outer VLAN tag also
must be defined.
If Translate is the Rewrite Type, a Translation Type drop-down list appears.
The choices available in this list vary depending on the setting of the Match Inner and Outer Tags
attribute (set in a previous step).
a.
If the Match Inner and Outer Tags check box is checked (true), choose a translation type of 1:1, 1:2,
2:1, or 2:2 from the Translation Type drop-down list.
– If you choose 1:1 or 2:1, enter a value in the Outer VLAN ID text box that appears. The outer
tag of all the incoming frames that fulfill the match criteria will be translated to this ID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-12
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
– If you choose 1:2 or 2:2, enter values in the Outer VLAN ID and Inner VLAN ID text boxes
that appear. The outer and inner tags of all the incoming frames that fulfill the match criteria
will be translated to these IDs.
b.
If the Match Inner and Outer Tags check box is unchecked (false), choose a translation type of 1:1
or 1:2 from the Translation Type drop-down list.
– If you choose 1:1, enter a value in the Outer VLAN ID text box that appears. The outer tag of
all the incoming frames that fulfill the match criteria will be translated to this ID.
– If you choose 1:2, enter values in the Outer VLAN ID and Inner VLAN ID text boxes that
appear. The outer and inner tags of all the incoming frames that fulfill the match criteria will be
translated to these IDs.
Step 21
Clicked Next to save the settings in the FlexUNI Details window.
The Standard UNI Details window appears, as shown in Figure 6-5.
Step 22
Continue with setting the standard UNI link attributes in the next steps.
Editing the Standard UNI Attributes
The following steps cover setting the attributes in the Standard UNI Details window. In the case of a link
which is not set as a FlexUNI link (by not checking the FlexUNI check box in the Service Request
Details window), editing the link attributes begins with this window.
Note
The attributes that appear in the Standard UNI Details window are dynamically configured by ISC. Some
of the attributes covered in the steps below might not appear in the window, depending on the policy and
service request settings or the link type. For example, if the MPLS core connectivity type of the
FlexUNI/EVC policy is local, the pseudowire-related attributes will not appear. Also, setting the link as
FlexUNI or non-FlexUNI will change the attributes that appear in the window. In addition, attributes are
filtered based on device type (IOS or IOS XR). These cases are noted in the steps, for reference.
Some possible presentations of the Standard UNI attributes are shown in Figure 6-4 through Figure 6-6.
Figure 6-4 is an example of a direct connect link for a Cisco 7600 device running IOS with pseudowire
core connectivity, configure bridge domain enabled, and the FlexUNI check box checked.
Figure 6-4
Standard UNI Details Window (Cisco 7600, Configure Bridge Domain Enabled)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-13
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Figure 6-5 is an example of a direct connect link for a Cisco ASR 9000 running IOS XR with pseudowire
core connectivity, configure bridge domain enabled, and the FlexUNI check box checked.
Figure 6-5
Standard UNI Details Window (Cisco ASR 9000, Configure Bridge Domain Enabled)
Figure 6-6 is an example of a direct connect link for a Cisco ASR 9000 running IOS XR with pseudowire
core connectivity, configure bridge domain not enabled, and the FlexUNI check box checked.
Figure 6-6
Step 23
Standard UNI Details Window (Cisco ASR 9000, Configure Bridge Domain not
Enabled)
The N-PE/U-PE Information and Interface Name fields display the PE device and interface name
selected in previous steps.
These fields are read-only.
Step 24
Choose an Encapsulation type from the drop-down list.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-14
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
The choices are:
•
DOT1QTRUNK—Configures the UNI as a trunk with 802.1q encapsulation. If the UNI belongs to
a directly connected and FlexUNI link, this setting signifies that the incoming frames are 802.1q
encapsulated and that they match the VLAN ID configured for the link. This specific topology does
not involve a trunk UNI as such.
•
DOT1QTUNNEL—Configures the UNI as an 802.1q tunnel (also known as a dot1q tunnel or
Q-in-Q) port.
•
ACCESS—Configures the UNI as an access port.
This attribute allows you to deploy different types of UNI encapsulation on different links of a service.
Step 25
In the PE/UNI Interface Description field, enter a description for the interface, if desired.
Step 26
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation
(for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time).
Step 27
Specify the type of VLAN Translation for the service request by clicking the appropriate radio button.
The choices are:
Step 28
•
No—No VLAN translation is performed. (This is the default.)
•
1:1—1:1 VLAN translation.
•
2:1—2:1 VLAN translation.
Note
VLAN translation, and all standard UNI and port security attributes are applicable for links with
L2 access. If the UNI is on an N-PE, these attributes will not appear.
Note
For detailed coverage of setting up VLAN translation, see Appendix C, “Setting Up VLAN
Translation.”
Check the N-PE Pseudo-wire on SVI check box to have ISC generate forwarding commands under SVIs
(switch virtual interfaces).
By default, this check box is not checked. In this case, ISC generates forwarding commands under the
service instance.
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (this is available in the service request workflow in the EVC Service
Request Editor window). N-PE Pseudo-wire on SVI, if enabled, will be reflected only when Configure
with Bridge Domain is set to true. Otherwise, the service request will not be created with xconnect under
SVI, even if N-PE Pseudo-wire on SVI is enabled.
Usage notes:
•
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (in the EVC Service Request Editor window). N-PE Pseudo-wire on
SVI, if enabled, will be reflected only when Configure with Bridge Domain is set to true. Otherwise,
the service request will not be created with scanned under SVI, even if N-PE pseudo-wire on SVI is
enabled.
•
ISC supports a hybrid configuration for FlexUNI/EVC service requests. In a hybrid configuration,
the forwarding commands (such as scanned) for one side of an attachment circuit can be configured
under a service instance, and the xconnect configuration for the other side of the attachment circuit
can be configured under a switch virtual interface (SVI).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-15
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 29
•
N-PE Pseudo-wire on SVI is applicable for all connectivity types (PSEUDOWIRE or LOCAL), but
a hybrid SVI configuration is possible only for pseudowire connectivity.
•
When MPLS Core Connectivity Type is set as LOCAL connectivity type, the N-PE Pseudo-wire on
SVI attribute is always disabled in the policy and service request.
•
For examples of these cases, see configlet examples FlexUNI/EVC (Pseudowire Core Connectivity,
Bridge Domain, Pseudowire on SVI) and FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge
Domain, no Pseudowire on SVI).
•
For additional information on the N-PE Pseudo-wire on SVI attribute, see the corresponding
coverage in the FlexUNI/EVC policy chapter in the section Setting the Interface Attributes,
page 3-16.
•
The N-PE Pseudo-wire on SVI attribute is not supported for IOS XR devices. All the xconnect
commands are configured on L2 subinterfaces/service instance.
Check the Use Existing PW Class check box to enable the selection of a pseudowire class.
This attribute is unchecked by default.
Usage notes:
Step 30
•
If Use Existing PW Class is checked, an additional attribute, Existing PW Class Name, appears in
the GUI. Enter the name of a pseudowire class which already exists in the device.
•
If Use Existing PW Class is checked, the PW Tunnel Selection and Interface Tunnel attributes will
disappear from the window. This is to prevent ISC from generating the pseudowire class.
•
The Use PseudoWireClass attribute is only available if the MPLS core connectivity type was set as
PSEUDOWIRE in the Service Options window (see Pseudowire Core Connectivity, page 6-3).
•
Use PseudoWireClass is only applicable for IOS XR devices.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
Usage notes:
Step 31
•
Checking the PW Tunnel Selection check box activates the Interface Tunnel attribute field (see the
next step).
•
This attribute only appears if the MPLS core connectivity type is set as pseudowire in the
FlexUNI/EVC policy.
If you checked the PW Tunnel Selection check box, enter the TE tunnel ID in the Interface Tunnel text
field.
ISC uses the tunnel information to create and provision a pseudowire class that describes the pseudowire
connection between two N-PEs. This pseudowire class can be shared by more than one pseudowire, as
long as the pseudowires share the same tunnel ID and remote loopback address. During service request
creation, ISC does not check the validity of the tunnel ID number. That is, ISC does not verify the
existence of the tunnel.
Step 32
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is unchecked by default.
Usage notes:
•
The pseudowire class name is used for provisioning pw-class commands on IOS XR devices. See
Creating and Modifying Pseudowire Classes for IOS XR Devices, page 2-10 for additional
information on pseudowire class support for IOS XR devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-16
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 33
•
If Use PseudoWireClass is checked, an additional attribute, PseudoWireClass, appears in the GUI.
Click the Select button of PseudoWireClass attribute to choose a pseudowire class previously
created in ISC.
•
The Use PseudoWireClass attribute is only available if the MPLS core connectivity type was set as
PSEUDOWIRE in the Service Options window (see Setting the Service Options, page 5-4).
•
Use PseudoWireClass is only applicable for IOS XR devices.
Check the AutoPick Bridge Group Name check box to have ISC autopick the bridge group name during
service request creation.
If this check box is unchecked, you are prompted to specify a bridge group name during service request
creation (see the next step).
Usage notes:
Step 34
•
This attribute only displays for IOS XR devices.
•
If the AutoPick Bridge Group Name check box is unchecked, enter an bridge group name in the
Bridge Group Name text field.
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID during
service request creation.
If this check box is unchecked, you are prompted to specify a VLAN ID during service request creation
(see the next step).
Usage notes:
Step 35
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain VLAN ID is picked from the existing ISC VLAN pool.
•
The AutoPick Bridge Domain/VLAN ID attribute appears for both Cisco 7600 and ASR 9000
devices. It will be displayed only for non-FlexUNI links.
If the AutoPick Bridge Domain/VLAN ID check box is unchecked, enter an ID number in the Bridge
Domain/VLAN ID text field.
Usage notes:
Step 36
•
If AutoPick Bridge Domain/VLAN ID is checked, this field is non-editable.
•
When a VLAN ID is manually allocated, ISC verifies the VLAN ID to see if it lies within ISC’s
VLAN ID pool. If the VLAN ID is in the pool but not allocated, the VLAN ID is allocated to the
service request. If the VLAN ID is in the pool and is already in use, ISC prompts you to allocate a
different VLAN ID. If the VLAN ID lies outside of the ISC VLAN ID pool, ISC does not perform
any verification about whether the VLAN ID allocated. The operator must ensure the VLAN ID is
available.
•
The Bridge Domain/VLAN ID text field appears for both Cisco 7600 and ASR 9000 devices. It will
be displayed only for non-FlexUNI links.
For L2VPN Group Name choose one of the following from the drop-down list:
•
ISC
•
VPNSC
Usage notes:
•
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-17
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Note
•
Step 37
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the
drop-down list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
L2VPN Group Name is only applicable for IOS XR devices.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
Usage notes:
•
If no value is specified for the E-Line Name, ISC autogenerates a default name as follows:
– For PSEUDOWIRE core connectivity type, the format is:
DeviceName--VC_ID
– For LOCAL core connectivity type, the format is:
DeviceName--VLAN_ID
If the default name is more than 32 characters, the device names are truncated.
•
Step 38
E-Line Name is only applicable for IOS XR devices.
Click OK to save the Standard UNI settings and return to the EVC Service Request window.
The value in the Link Attributes column now displays as “Changed,” signifying that the link settings
have been updated. You can edit the link attributes now or at a future time by clicking on the Changed
link and modifying the settings in the Standard UNI Details window.
See Modifying the FlexUNI/EVC Service Request, page 6-23 for details on editing the link attributes.
Step 39
To add another link click the Add button and set the attributes for the new link as in the previous steps
in this section.
Step 40
To delete a link, check the check box in the first column of the row for that link and click the Delete
button.
Step 41
If you want to set up links with L2 access nodes for this service request, see Setting Links with L2 Access
Nodes, page 6-22.
Step 42
When you have completed setting the attributes in the EVC Service Request Editor window, click the
Save button at the bottom of the window to save the settings and create the FlexUNI/EVC service
request.
If any attributes are missing or incorrectly set, ISC displays a warning in the lower left of the window.
Make any corrections or updates needed (based on the information provided by ISC), and click the Save
button.
For information on modifying a FlexUNI/EVC service request see the section Modifying the
FlexUNI/EVC Service Request, page 6-23. For additional information about saving a FlexUNI/EVC
service request, see Saving the FlexUNI/EVC Service Request, page 6-24.
Setting the ATM Link Attributes
This section describes how to set up a direct connect link as an ATM link.
Perform the following steps to set up the ATM link.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-18
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 1
In the Direct Connect Links section of the FlexUNI(EVC) Service Request Editor window, specify the
device for which you would like to set up an ATM link.
Step 2
Choose an ATM interface for the UNI.
Note
ATM interfaces are displayed in the drop-down list in the UNI column only if the FlexUNI/EVC
service request is based on an ATM-Ethernet Interworking policy type.
When you choose an ATM interface, the check box in the FlexUNI(EVC) column dynamically
disappears from the GUI.
Step 3
In the Link Attributes column, click the Edit link of the device on which you want to add an ATM link.
The ATM-Ethernet Attributes window appears, as shown in Figure 6-7.
Figure 6-7
ATM-Ethernet Attributes Window
All of the fields in the ATM-Ethernet Attributes window are enabled based on the policy settings.
Step 4
Choose the Transport Mode from the drop-down list.
The choices are:
Step 5
•
VP—Virtual path mode. This is the default.
•
VC—Virtual circuit mode.
Choose the ATM Encapsulation from the drop-down list.
•
Step 6
AAL5SNAP
To specify the ATM virtual channel descriptor (VCD)/subinterface number, enter a value in the ATM
VCD/Sub-Interface # field.
The value can be from 1 to 2147483647.
Step 7
To specify the ATM virtual path identifier (VPI), enter a value in the ATM VPI field.
The value can be from 0 to 255.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-19
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 8
To specify the ATM virtual channel identifier (VCI), a value in the ATM VCI field.
The value can be from 32 to 65535.
Step 9
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation
(for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time).
Step 10
Check the Use Existing PW Class check box to enable the selection of a pseudowire class.
This attribute is unchecked by default.
Usage notes:
Step 11
•
If Use Existing PW Class is checked, an additional attribute, Existing PW Class Name, appears in
the GUI. Enter the name of a pseudowire class which already exists in the device.
•
If Use Existing PW Class is checked, the PW Tunnel Selection and Interface Tunnel attributes will
disappear from the window. This is to prevent ISC from generating the pseudowire class.
•
The Use PseudoWireClass attribute is only available if the MPLS core connectivity type was set as
PSEUDOWIRE in the Service Options window (see Pseudowire Core Connectivity, page 6-3).
•
Use PseudoWireClass is only applicable for IOS XR devices.
Check the N-PE Pseudo-wire on SVI check box to have ISC generate forwarding commands under SVIs
(switch virtual interfaces).
By default, this check box is not checked. In this case, ISC generates forwarding commands under the
service instance.
For a FlexUNI link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (this is available in the service request workflow in the EVC Service
Request Editor window). N-PE Pseudo-wire on SVI, if enabled, will be reflected only when Configure
with Bridge Domain is set to true. Otherwise, the service request will not be created with xconnect under
SVI, even if N-PE Pseudo-wire on SVI is enabled.
Usage notes:
•
For an ATM link, the attribute N-PE Pseudo-wire on SVI is dependent on the value of the attribute
Configure with Bridge Domain (in the EVC Service Request Editor window). N-PE Pseudo-wire on
SVI, if enabled, will be reflected only when Configure with Bridge Domain is set to true. Otherwise,
the service request will not be created with xconnect under SVI, even if N-PE pseudo-wire on SVI
is enabled.
•
ISC supports a hybrid configuration for FlexUNI/EVC service requests. In a hybrid configuration,
the forwarding commands (such as xconnect) for one side of an attachment circuit can be configured
under a service instance, and the xconnect configuration for the other side of the attachment circuit
can be configured under a switch virtual interface (SVI).
•
N-PE Pseudo-wire on SVI is applicable for all connectivity types (PSEUDOWIRE or LOCAL), but
a hybrid SVI configuration is possible only for pseudowire connectivity.
•
When MPLS Core Connectivity Type is set as LOCAL connectivity type, the N-PE Pseudo-wire on
SVI attribute is always disabled in the policy and service request.
•
For examples of these cases, see configlet examples FlexUNI/EVC (Pseudowire Core Connectivity,
Bridge Domain, Pseudowire on SVI) and FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge
Domain, no Pseudowire on SVI).
•
For additional information on the N-PE Pseudo-wire on SVI attribute, see the corresponding
coverage in the FlexUNI/EVC policy chapter in the section Setting the Interface Attributes,
page 3-16.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-20
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
•
Step 12
The N-PE Pseudo-wire on SVI attribute is not supported for IOS XR devices. All the xconnect
commands are configured on L2 subinterfaces/service instance.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
Usage notes:
Step 13
•
Checking the PW Tunnel Selection check box activates the Interface Tunnel attribute field (see the
next step).
•
This attribute only appears if the MPLS core connectivity type is set as pseudowire in the
FlexUNI/EVC policy.
If you checked the PW Tunnel Selection check box, enter the TE tunnel ID in the Interface Tunnel text
field.
ISC uses the tunnel information to create and provision a pseudowire class that describes the pseudowire
connection between two N-PEs. This pseudowire class can be shared by more than one pseudowire, as
long as the pseudowires share the same tunnel ID and remote loopback address. During service request
creation, ISC does not check the validity of the tunnel ID number. That is, ISC does not verify the
existence of the tunnel.
Step 14
Check the AutoPick Bridge Domain/VLAN ID check box to have ISC autopick the VLAN ID during
service request creation.
If this check box is unchecked, you are prompted to specify a VLAN ID during service request creation
(see the next step).
Usage notes:
Step 15
•
AutoPick Bridge Domain/VLAN ID consumes a global VLAN ID on the device.
•
The bridge domain VLAN ID is picked from the existing ISC VLAN pool.
If the AutoPick Bridge Domain/VLAN ID check box is unchecked, enter an ID number in the Bridge
Domain/VLAN ID text field.
Usage notes:
Step 16
•
If AutoPick Bridge Domain/VLAN ID is checked, this field is non-editable.
•
When a VLAN ID is manually allocated, ISC verifies the VLAN ID to see if it lies within ISC’s
VLAN ID pool. If the VLAN ID is in the pool but not allocated, the VLAN ID is allocated to the
service request. If the VLAN ID is in the pool and is already in use, ISC prompts you to allocate a
different VLAN ID. If the VLAN ID lies outside of the ISC VLAN ID pool, ISC does not perform
any verification about whether the VLAN ID allocated. The operator must ensure the VLAN ID is
available.
Click OK to save the ATM-Ethernet Attributes settings and return to the FlexUNI(EVC) Service Request
Editor window.
The value in the Link Attributes column now displays as “Changed,” signifying that the link settings
have been updated. You can edit the link attributes now or at a future time by clicking on the Changed
link and modifying the settings in the Standard UNI Details window.
See Modifying the FlexUNI/EVC Service Request, page 6-23 for details on editing the link attributes.
Step 17
To add another link click the Add button and set the attributes for the new link as in the previous steps
in this section.
Step 18
To delete a link, check the check box in the first column of the row for that link and click the Delete
button.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-21
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Setting the Service Request Details
Step 19
If you want to set up links with L2 access nodes for this service request, see Setting Links with L2 Access
Nodes, page 6-22.
Step 20
When you have completed setting the attributes in the FlexUNI(EVC) Service Request Editor window,
click the Save button at the bottom of the window to save the settings and create the FlexUNI/EVC
service request.
If any attributes are missing or incorrectly set, ISC displays a warning in the lower left of the window.
Make any corrections or updates needed (based on the information provided by ISC), and click the Save
button.
For information on modifying a FlexUNI/EVC service request see the section Modifying the
FlexUNI/EVC Service Request, page 6-23. For additional information about saving a FlexUNI/EVC
service request, see Saving the FlexUNI/EVC Service Request, page 6-24.
Setting Links with L2 Access Nodes
The Links with L2 Access Nodes section of the FlexUNI(EVC) Service Request Editor window allows
you to set up links with L2 (Ethernet) access nodes. These are similar to direct connect links, except that
they have L2/Ethernet access nodes beyond the N-PE (towards the CE). Therefore, NPCs are involved.
Note
ATM links are not supported in L2 access nodes. ATM links must be set up as direct connect links. For
more information, see Setting the ATM Link Attributes, page 6-18.
The steps for setting up links with L2 access nodes are similar to those covered in the section Setting
Direct Connect Links, page 6-8. See that section for detailed steps on the following common operations:
•
Adding and deleting links.
•
Selecting the N-PE.
•
Choosing the UNI interface.
•
Setting the link as a FlexUNI link.
•
Editing the standard and FlexUNI link attributes.
The main difference in setting up links with L2 access does is specifying the NPC details.
Perform the following steps to set the NPC details for links with L2 access nodes:
Step 1
The first step in the process of adding a link using NPCs is selecting the U-PE/PE-AGG device, rather
than the N-PE.
If only one NPC exists for the chosen interface, that NPC is autopopulated in the Circuit Details column,
and you need not choose it explicitly.
If more then one NPC is available, click Select one circuit in the Circuit Selection column. The NPC
window appears, enabling you to choose the appropriate NPC.
Step 2
Click OK.
Each time you choose a PE and its interface, the NPC that was set up from this PE and interface is
automatically displayed under Circuit Selection. This means that you do not have to further specify the
PE to complete the link.
If you want to review the details of this NPC, click Circuit Details in the Circuit Details column. The
NPC Details window appears and lists the circuit details for this NPC.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-22
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Modifying the FlexUNI/EVC Service Request
Step 3
For details about editing link attributes, adding or deleting links, or using the FlexUNI check box, see
the corresponding steps in the section Setting Direct Connect Links, page 6-8.
Step 4
When you have completed setting the attributes in the EVC Service Request Editor window, click the
Save button at the bottom of the window to save the settings and create the FlexUNI/EVC service
request.
If any attributes are missing or incorrectly set, ISC displays a warning in the lower left of the window.
Make any corrections or updates needed (based on the information provided by ISC), and click the Save
button.
For information on modifying a FlexUNI/EVC service request see the section Modifying the
FlexUNI/EVC Service Request, page 6-23. For additional information about saving a FlexUNI/EVC
service request, see Saving the FlexUNI/EVC Service Request, page 6-24.
Modifying the FlexUNI/EVC Service Request
You can modify a FlexUNI/EVC service request if you must change or modify the links or other settings
of the service request.
To modify a FlexUNI/EVC service request, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears, showing service request available in ISC.
Step 2
Check a check box for a service request.
Step 3
Click Edit.
EVC Service Editor window appears.
Step 4
Modify any of the attributes, as desired.
See the sections start with “Setting the Service Request Details” section on page 6-3 for detailed
coverage of setting attributes in this window.
Note
Once the VC ID, VPLS VPN ID, and VLAN ID have been set in a service request they cannot
be modified.
Step 5
To add a template/data file to an attachment circuit, see the section Using Templates and Data Files with
a FlexUNI/EVC Service Request, page 6-24.
Step 6
When you are finished editing the FlexUNI/EVC service request, click Save.
For additional information about saving a FlexUNI/EVC service request, see Saving the FlexUNI/EVC
Service Request, page 6-24.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-23
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Using Templates and Data Files with a FlexUNI/EVC Service Request
Using Templates and Data Files with a FlexUNI/EVC Service
Request
ISC does not support configuration of all the available CLI commands on a device being managed by the
application. In order to configure such commands on the devices, you can use ISC Template Manager
functionality. Templates can be associated at the policy level on a per-device role basis. Templates can
be overridden at service request level, if the policy-level setting permits the operator to do so.
To associate templates and data files in a service request select any link in the Service Request Editor
window and click the Template button at the bottom of the window.
Note
If the template feature has not been enabled in the associated policy then the Template button will not
be available for selection.
The SR Template Association window appears, as shown in Figure 6-8. In this window, you can
associate templates at a per-device level.
Figure 6-8
Sample Templates Association Window
As shown in Figure 6-8, the Template Association window lists the devices comprising the link, the
device roles, and the template(s)/data file(s) associated with the devices. In this case, the
template(s)/data file(s) have not yet been set up.
For further instructions on how to associate templates and data files with a service request, see
Appendix B, “Working with Templates and Data Files,” especially the section Using Templates with
Service Requests, page B-10.
Saving the FlexUNI/EVC Service Request
To save a FlexUNI/EVC service request, perform the following steps.
Step 1
When you have finished setting the attributes for the FlexUNI/EVC service request, click Save to create
the service request.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-24
OL-21636-01
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Saving the FlexUNI/EVC Service Request
If the FlexUNI/EVC service request is successfully created, you will see the service request list window,
similar to what appears in Figure 6-9.
Figure 6-9
FlexUNI/EVC Service Request Created
The newly created FlexUNI/EVC service request is added with the state of REQUESTED, as shown in
the figure.
Step 2
If, however, the FlexUNI service request creation failed for some reason (for example, a value chosen is
out of bounds), you are warned with an error message.
In such a case, you should correct the error and save the service request again.
Step 3
If you are ready to deploy the FlexUNI/EVC service request, see Deploying Service Requests,
page 11-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
6-25
Chapter 6
Managing a FlexUNI/EVC ATM-Ethernet Interworking Service Request
Saving the FlexUNI/EVC Service Request
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
6-26
OL-21636-01
CH A P T E R
7
Creating an L2VPN Policy
This chapter covers the basic steps to create an L2VPN policy. It contains the following sections:
•
Defining an L2VPN Policy, page 7-1
•
Defining an Ethernet ERS (EVPL) Policy with a CE, page 7-3
•
Defining an Ethernet ERS (EVPL) Policy without a CE, page 7-9
•
Defining an Ethernet EWS (EPL) Policy with a CE, page 7-15
•
Defining an Ethernet EWS (EPL) Policy without a CE, page 7-22
•
Defining a Frame Relay Policy with a CE, page 7-28
•
Defining a Frame Relay Policy without a CE, page 7-31
•
Defining an ATM Policy with a CE, page 7-33
•
Defining an ATM Policy without a CE, page 7-36
Defining an L2VPN Policy
You must define an L2VPN policy before you can provision a Cisco IP Solution Center (ISC) service.
An L2VPN policy defines the common characteristics shared by the end-to-end wire attributes and
Attachment Circuit (AC) attributes.
A policy is a template of most of the parameters needed to define an L2VPN service request. After you
define it, an L2VPN policy can be used by all the L2VPN service requests that share a common set of
characteristics. You create a new L2VPN policy whenever you create a new type of service or a service
with different parameters. L2VPN policy creation is normally performed by experienced network
engineers.
A policy can be shared by one or more service requests that have similar service requirements. The
Editable check box gives the network operator the option of making a field editable. If the value is set
to editable, the service request creator can change to other valid values for the particular policy item. If
the value is not set to editable, the service request creator cannot change the policy item.
The four major categories of an L2VPN policy correspond to the four major services that L2VPN
provides:
•
Point-to-point Ethernet Relay Service (ERS). The Metro Ethernet Forum (MEF) name for this
service is Ethernet Virtual Private Line (EVPL). See Layer 2 Terminology Conventions, page E-1
for more information about terms used to denote L2VPN services in this guide.
•
Point-to-point Ethernet Wire Service (EWS). The MEF name for this service is Ethernet Private Line
(EPL).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-1
Chapter 7
Creating an L2VPN Policy
Defining an L2VPN Policy
•
Frame Relay over MPLS (FRoMPLS)
•
ATM over MPLS (ATMoMPLS)
To define an L2VPN policy in ISC, perform the following steps.
Step 1
Choose Service Design > Policies.
The Policies window appears.
Step 2
Click Create.
Step 3
Choose L2VPN (P2P) Policy.
When you choose L2VPN (P2P) Policy, the L2VPN (Point to Point) Policy Creation window appears.
Step 4
Choose L2VPN on MPLS Core.
The window in Figure 7-1 appears.
Figure 7-1
Creating an L2VPN Policy
Step 5
Enter a Policy Name for the L2VPN policy.
Step 6
Choose the Policy Owner for the L2VPN policy.
There are three types of L2VPN policy ownership:
•
Customer ownership
•
Provider ownership
•
Global ownership—Any service operator can make use of this L2VPN policy.
This ownership has relevance when the ISC Role-Based Access Control (RBAC) comes into play. For
example, an L2VPN policy that is customer-owned can only be seen by operators who are allowed to
work on this customer-owned policy.
Similarly, operators who are allowed to work on a provider’s network can view, use, and deploy a
particular provider-owned policy.
Step 7
Click Select to choose the owner of the L2VPN.
(If you choose Global ownership, the Select function is not available.) The Select Customer window or
the Select Provider window appears and you can choose an owner of the policy and click Select.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-2
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy with a CE
Step 8
Choose the Service Type of the L2VPN policy.
There are four service types for L2VPN policies:
•
L2VPN ERS (EVPL)
•
L2VPN EWS (EPL)
•
Frame Relay
•
ATM
Subsequent sections of this chapter cover setting up the policies for each of these services.
Step 9
Check the CE Present check box if you want ISC to ask the service operator who uses this L2VPN
policy to provide a CE router and interface during service activation.
The default is CE present in the service.
If you do not check the CE Present check box, ISC asks the service operator, during service activation,
only for the U-PE or the N-PE router and customer-facing interface.
Step 10
Click Next.
The next sections contain examples of setting policies for the service types, with and without a CE
present.
Defining an Ethernet ERS (EVPL) Policy with a CE
This section describes defining an Ethernet ERS (EVPL) policy with CE present. Figure 7-2 is an
example of the first page of this policy.
Figure 7-2
Ethernet ERS (EVPL) Policy with a CE
Perform the following steps.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-3
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy with a CE
Step 1
Click Next. The window in Figure 7-3 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Figure 7-3
Step 2
Ethernet ERS (EVPL) with CE Policy Attributes
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Note
Step 3
The Standard UNI Port attribute will be unavailable within service requests based on this policy if the
UNI is on an N-PE device running IOS XR.
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a U-PE or N-PE interface based on the service provider’s POP
design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-4
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy with a CE
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during
L2VPN service request creation.
Step 4
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose an Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Note
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 10
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 11
Check the VC ID AutoPick check box if you want ISC to choose a VC ID.
If you do not check this check box, you will be prompted to provide the VC ID in a VC ID field during
service activation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-5
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy with a CE
Step 12
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique.
Step 13
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is only applicable for IOS XR devices. If the check box is checked, an additional attribute,
PseudoWireClass, appears in the GUI. Click the Select button of PseudoWireClass attribute to choose
a pseudowire class previously created in ISC. The pseudowire class name is used for provisioning
pw-class commands on IOS XR devices. See Creating and Modifying Pseudowire Classes for IOS XR
Devices, page 2-10 for additional information on pseudowire class support for IOS XR devices.
Step 14
Choose an L2VPN Group Name from the drop-down list.
The choices are:
•
ISC
•
VPNSC
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 15
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the drop-down
list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
This attribute is only applicable for IOS XR devices. If no value is specified for the p2p name, ISC
generates a default name consisting of the names of the two PEs forming the pseudowire, separated by
hyphens (for example, 6503-A----6503-B). If the default name is more than 32 characters, the device
names are truncated.
Step 16
Enter a Link Media type (optional) of None, auto-select, rj45, or sfp.
Usage notes:
•
The default is None.
•
When this attribute is used, a new CLI will be generated in the UNI interface to define the media
type.
•
The Link Media attribute is supported only for ME3400 platforms.
Step 17
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 18
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 19
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this box is unchecked and ISC automatically assigns a MAC-based ACL on the customer
facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 20
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-6
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy with a CE
Step 21
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 22
Choose a UNI Port Type.
The choices are:
•
Access Port
•
Trunk with Native VLAN
Note
Step 23
Enter a UNI Port Type only if the encapsulation type is DEFAULT.
Check the UNI Port Security check box (see Figure 7-4) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 7-4
Step 24
UNI Port Security
Check the Enable Storm Control check box (see Figure 7-5) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-7
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy with a CE
Figure 7-5
Step 25
Enable Storm Control
Check the N-PE Pseudo-wire On SVI check box to configure the pseudowire connection on the
switched virtual interface of the OSM card.
This check box is checked by default. If the check box is not checked, the pseudowire will be provisioned
on the subinterface of the PFC card, if it is available. This option is only available for C76xx devices.
Note
Step 26
The N-PE Pseudo-wire on SVI attribute will be unavailable within service requests based on this policy
for devices running IOS XR.
Specify the type of VLAN Translation for this policy by clicking the appropriate radio button.
The choices are:
•
No—No VLAN translation is performed. (This is the default.)
•
1:1—1:1 VLAN translation.
•
2:1—2:1 VLAN translation.
Note
Step 27
For detailed coverage of setting up VLAN translation, see Appendix C, “Setting Up VLAN
Translation.”
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Note
Step 28
The PW Tunnel Selection attribute will be unavailable within service requests based on this policy for
devices running IOS XR.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-8
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy without a CE
Step 29
Click Finish.
Defining an Ethernet ERS (EVPL) Policy without a CE
This section describes defining an Ethernet ERS (EVPL) policy without a CE present. Figure 7-6 is an
example of the first page of this policy.
Figure 7-6
Ethernet ERS (EVPL) Policy without a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-7 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-9
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy without a CE
Figure 7-7
Step 2
Ethernet ERS (EVPL) without CE Policy Attributes
Choose a N-PE/U-PE Interface Type from the drop-down list.
You can choose a particular interface as a CE, N-PE, or U-PE interface based on the service provider’s
POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during
L2VPN service request creation.
Step 3
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-10
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy without a CE
Note
Step 4
The Standard UNI Port attribute will be unavailable within service requests based on this policy if the
UNI is on an N-PE device running IOS XR.
Enter an Interface Format as the slot number/port number for the PE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose an Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Note
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 10
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID. If you do not check
this check box, you will be prompted to provide the VLAN in a Provider VLAN ID field during service
activation.
Step 11
Check the VC ID AutoPick check box if you want ISC to choose a VC ID.
If you do not check this check box, you will be prompted to provide the VC ID in a VC ID field during
service activation.
Step 12
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is only applicable for IOS XR devices. If the check box is checked, an additional attribute,
PseudoWireClass, appears in the GUI. Click the Select button of PseudoWireClass attribute to choose
a pseudowire class previously created in ISC. The pseudowire class name is used for provisioning
pw-class commands on IOS XR devices. See Creating and Modifying Pseudowire Classes for IOS XR
Devices, page 2-10 for additional information on pseudowire class support for IOS XR devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-11
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy without a CE
Step 13
Choose an L2VPN Group Name from the drop-down list.
The choices are:
•
ISC
•
VPNSC
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 14
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the drop-down
list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
This attribute is only applicable for IOS XR devices. If no value is specified for the p2p name, ISC
generates a default name consisting of the names of the two PEs forming the pseudowire, separated by
hyphens (for example, 6503-A----6503-B). If the default name is more than 32 characters, the device
names are truncated.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique.
Step 16
Enter a Link Media type (optional) of None, auto-select, rj45, or sfp.
Usage notes:
•
The default is None.
•
When this attribute is used, a new CLI will be generated in the UNI interface to define the media
type.
•
The Link Media attribute is supported only for ME3400 platforms.
Step 17
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 18
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 19
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is unchecked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 20
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
Step 21
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you unchecked the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 22
Choose a UNI Port Type.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-12
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy without a CE
The choices are:
•
Access Port
•
Trunk with Native VLAN
Note
Step 23
Enter a UNI Port Type only if the encapsulation type is DEFAULT.
Check the UNI Port Security check box (see Figure 7-8) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 7-8
Step 24
UNI Port Security
Check the Enable Storm Control check box (see Figure 7-9) to help prevent the UNI port from being
disrupted by a broadcast, multicast, or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 7-9
Enable Storm Control
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-13
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet ERS (EVPL) Policy without a CE
Step 25
Check the N-PE Pseudo-wire On SVI check box to configure the pseudowire connection on the
switched virtual interface of the OSM card.
This check box is checked by default. If the check box is not checked, the pseudowire will be provisioned
on the subinterface of the PFC card, if it is available. This option is only available for C76xx devices.
Note
Step 26
The N-PE Pseudo-wire On SVI attribute will be unavailable within service requests based on this policy
for devices running IOS XR.
Specify the type of VLAN Translation for this policy by clicking the appropriate radio button.
The choices are:
•
No—No VLAN translation is performed. (This is the default.)
•
1:1—1:1 VLAN translation.
•
2:1—2:1 VLAN translation.
Note
Step 27
For detailed coverage of setting up VLAN translation, see Appendix C, “Setting Up VLAN
Translation.”
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Note
Step 28
The PW Tunnel Selection attribute will be unavailable within service requests based on this policy for
devices running IOS XR.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 29
Click Finish.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-14
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
Defining an Ethernet EWS (EPL) Policy with a CE
This section describes defining an Ethernet EWS (EPL) policy with CE present. Figure 7-10 is an
example of the first page of this policy.
Figure 7-10
Ethernet EWS (EPL) Policy with a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-11 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-15
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
Figure 7-11
Step 2
Ethernet EWS (EPL) with CE Policy Attributes
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Note
The Standard UNI Port attribute will be unavailable within service requests based on this policy if the
UNI is on an N-PE device running IOS XR.
Note
In previous releases, the only Layer 2 VPN support for EWS (EPL) was from EWS (EPL) to EWS (EPL).
In ISC 4.1.2 and later, support is also from EWS (EPL) to Network to Network Interface (NNI) as a trunk
port. To create this new type of service request, you need to create an EWS (EPL) “hybrid” policy by
unchecking the standard UNI flag. When using the EWS (EPL) hybrid policy for service request
creation, check the Standard UNI Port flag for the EWS (EPL) side of the connection and uncheck the
standard UNI flag for the NNI side of the connection.
Note
In the case of hybrid services, UNI on an N-PE running IOS XR is not supported.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-16
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
Step 3
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a U-PE or N-PE interface based on the service provider’s POP
design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during
L2VPN service request creation.
Step 4
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose an Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Note
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-17
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
Step 10
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 11
Check the VC ID AutoPick check box if you want ISC to choose a VC ID.
If you do not check this check box, you will be prompted to provide the VC ID in a VC ID field during
service activation.
Step 12
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is only applicable for IOS XR devices. If the check box is checked, an additional attribute,
PseudoWireClass, appears in the GUI. Click the Select button of PseudoWireClass attribute to choose
a pseudowire class previously created in ISC. The pseudowire class name is used for provisioning
pw-class commands on IOS XR devices. See Creating and Modifying Pseudowire Classes for IOS XR
Devices, page 2-10 for additional information on pseudowire class support for IOS XR devices.
Step 13
Choose an L2VPN Group Name from the drop-down list.
The choices are:
•
ISC
•
VPNSC
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 14
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the drop-down
list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
This attribute is only applicable for IOS XR devices. If no value is specified for the p2p name, ISC
generates a default name consisting of the names of the two PEs forming the pseudowire, separated by
hyphens (for example, 6503-A----6503-B). If the default name is more than 32 characters, the device
names are truncated.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique.
Step 16
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID. If you do not check
this check box, you will be prompted to provide the VLAN in a Provider VLAN ID field during service
activation.
Step 17
Enter a Link Media type (optional) of None, auto-select, rj45, or sfp.
Usage notes:
•
The default is None.
•
When this attribute is used, a new CLI will be generated in the UNI interface to define the media
type.
•
The Link Media attribute is supported only for ME3400 platforms.
Step 18
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 19
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-18
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
Step 20
Check the Use Existing ACL Name check box if you want assign your own named access list to the
port. By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 21
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
Step 22
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 23
Check the UNI Port Security check box (see Figure 7-12) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 7-12
Step 24
UNI Port Security
Check the Enable Storm Control check box (see Figure 7-13) to help prevent the UNI port from being
disrupted by a broadcast, multicast, or unicast storm. Enter a threshold value for each type of traffic.
The value, which can be specified to two significant digits, represents the percentage of the total
available bandwidth of the port. If the threshold of a traffic type is reached, further traffic of that type is
suppressed until the incoming traffic falls below the threshold level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-19
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
Figure 7-13
Step 25
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 7-14) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 7-14
Protocol Tunnelling
For each protocol that you choose, enter the shutdown threshold and drop threshold for that protocol:
Step 26
a.
Enable cdp—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
cdp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Enable vtp—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
vtp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Enable stp—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
stp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Check the N-PE Pseudo-wire On SVI check box to configure the pseudowire connection on the
switched virtual interface of the OSM card.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-20
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy with a CE
This check box is checked by default. If the check box is not checked, the pseudowire will be provisioned
on the subinterface of the PFC card, if it is available. This option is only available for C76xx devices.
Note
Step 27
The N-PE Pseudo-wire On SVI attribute will be unavailable within service requests based on this policy
for devices running IOS XR.
Enter the MTU Size in bytes.
The maximum transmission unit (MTU) size is configurable and optional. The default size is 9216, and
the range is 1500 to 9216. ISC does not perform an integrity check for this customized value. If a service
request goes to the Failed Deploy state because this size is not accepted, you must adjust the size until
the Service Request is deployed.
In ISC 6.0, different platforms support different ranges.
Step 28
•
For the 3750 and 3550 platforms, the MTU range is 1500-1546.
•
For the 7600 ethernet port, the MTU size is always 9216. Even with the same platform and same
IOS release, different line cards support the MTU differently. For example, older line cards only take
an MTU size of 9216 and newer cards support 1500-9216. However, ISC 6.0 uses 9216 in both cases.
•
For the 7600 SVI (interface VLAN), the MTU size is 1500-9216.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Note
Step 29
The PW Tunnel Selection attribute will be unavailable within service requests based on this policy for
devices running IOS XR.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 30
Click Finish.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-21
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy without a CE
Defining an Ethernet EWS (EPL) Policy without a CE
This section describes how to define an Ethernet EWS (EPL) policy without a CE present. Figure 7-15
is an example of the first page of this policy.
Figure 7-15
Ethernet EWS (EPL) Policy without a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-16 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-22
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy without a CE
Figure 7-16
Step 2
Ethernet EWS (EPL) without CE Policy Attributes
Choose a N-PE/U-PE Interface Type from the drop-down list.
You can choose a particular interface as a CE, N-PE, or U-PE interface based on the service provider’s
POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during
L2VPN service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-23
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy without a CE
Step 3
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Note
The Standard UNI Port attribute will be unavailable within service requests based on this policy if the
UNI is on an N-PE device running IOS XR.
Note
In previous releases, the only Layer 2 VPN support for EWS (EPL) was from EWS (EPL) to EWS (EPL).
In ISC 4.1.2 and later, support is also from EWS (EPL) to Network to Network Interface (NNI) as a trunk
port. To create this new type of service request, you need to create an EWS (EPL) “hybrid” policy by
unchecking the standard UNI flag. When using the EWS (EPL) hybrid policy for service request
creation, check the Standard UNI Port flag for the EWS (EPL) side of the connection and uncheck the
standard UNI flag for the NNI side of the connection.
Note
In the case of hybrid services, UNI on an N-PE running IOS XR is not supported.
Step 4
Enter an Interface Format as the slot number/port number for the PE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose an Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Note
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is not checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is not checked by default.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-24
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy without a CE
Step 10
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 11
Check the VC ID AutoPick check box if you want ISC to choose a VC ID.
If you do not check this check box, you will be prompted to provide the VC ID in a VC ID field during
service activation.
Step 12
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is only applicable for IOS XR devices. If the check box is checked, an additional attribute,
PseudoWireClass, appears in the GUI. Click the Select button of PseudoWireClass attribute to choose
a pseudowire class previously created in ISC. The pseudowire class name is used for provisioning
pw-class commands on IOS XR devices. See Creating and Modifying Pseudowire Classes for IOS XR
Devices, page 2-10 for additional information on pseudowire class support for IOS XR devices.
Step 13
Choose an L2VPN Group Name from the drop-down list.
The choices are:
•
ISC
•
VPNSC
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 14
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the drop-down
list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
This attribute is only applicable for IOS XR devices. If no value is specified for the p2p name, ISC
generates a default name consisting of the names of the two PEs forming the pseudowire, separated by
hyphens (for example, 6503-A----6503-B). If the default name is more than 32 characters, the device
names are truncated.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique.
Step 16
Enter a Link Media type (optional) of None, auto-select, rj45, or sfp.
Usage notes:
•
The default is None.
•
When this attribute is used, a new CLI will be generated in the UNI interface to define the media
type.
•
The Link Media attribute is supported only for ME3400 platforms.
Step 17
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 18
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 19
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-25
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy without a CE
Step 20
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
Step 21
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 22
Check the UNI Port Security check box (see Figure 7-4) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 7-17
Step 23
UNI Port Security
Check the Enable Storm Control check box (see Figure 7-18) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-26
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an Ethernet EWS (EPL) Policy without a CE
Figure 7-18
Step 24
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 7-14) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 7-19
Protocol Tunnelling
For each protocol that you check, enter the shutdown threshold and drop threshold for that protocol:
Step 25
a.
Enable cdp—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
cdp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Enable vtp—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
vtp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Enable stp—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
stp shutdown threshold—Enter the number of packets per second to be received before the
interface is shut down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Check the N-PE Pseudo-wire On SVI check box to configure the pseudowire connection on the
switched virtual interface of the OSM card.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-27
Chapter 7
Creating an L2VPN Policy
Defining a Frame Relay Policy with a CE
This check box is checked by default. If the check box is not checked, the pseudowire will be provisioned
on the subinterface of the PFC card, if it is available. This option is only available for C76xx devices.
Note
Step 26
The N-PE Pseudo-wire On SVI attribute will be unavailable within service requests based on this policy
for devices running IOS XR.
Enter the MTU Size in bytes.
The maximum transmission unit (MTU) size is configurable and optional. The default size is 9216, and
the range is 1500 to 9216. ISC does not perform an integrity check for this customized value. If a service
request goes to the Failed Deploy state because this size is not accepted, you must adjust the size until
the Service Request is deployed.
In ISC 6.0, different platforms support different ranges.
Step 27
•
For the 3750 and 3550 platforms, the MTU range is 1500-1546.
•
For the 7600 ethernet port, the MTU size is always 9216. Even with the same platform and same
IOS release, different line cards support the MTU differently. For example, older line cards only take
an MTU size of 9216 and newer cards support 1500-9216. However, ISC 6.0 uses 9216 in both cases.
•
For the 7600 SVI (interface VLAN), the MTU size is 1500-9216.
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Note
Step 28
The PW Tunnel Selection attribute will be unavailable within service requests based on this policy for
devices running IOS XR.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 29
Click Finish.
Defining a Frame Relay Policy with a CE
This section describes how to define a Frame Relay policy with CE present. Figure 7-20 is an example
of the first page of this policy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-28
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining a Frame Relay Policy with a CE
Note
Frame Relay policies are not supported for devices running IOS XR.
Figure 7-20
Frame Relay Policy with a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-21 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Figure 7-21
Step 2
Frame Relay with CE Policy Attributes
Choose the Interface Type for the CE from the drop-down list.
The choices are:
•
ANY
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-29
Chapter 7
Creating an L2VPN Policy
Defining a Frame Relay Policy with a CE
Step 3
•
Serial
•
MFR
•
POS
•
Hssi
•
BRI
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 4
Choose the CE Encapsulation type.
The choices are:
Note
•
FRAME RELAY
•
FRAME RELAY IETF
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 5
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 6
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Step 7
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 8
Click Finish.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-30
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining a Frame Relay Policy without a CE
Defining a Frame Relay Policy without a CE
This section describes how to define a Frame Relay policy without a CE present. Figure 7-22 is an
example of the first page of this policy.
Figure 7-22
Frame Relay Policy without a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-23 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Figure 7-23
Frame Relay without CE Policy Attributes
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-31
Chapter 7
Creating an L2VPN Policy
Defining a Frame Relay Policy without a CE
Step 2
Choose the N-PE/U-PE Interface Type for the CE from the drop-down list.
The choices are:
Step 3
•
ANY
•
Serial
•
MFR
•
POS
•
Hssi
•
BRI
Enter an Interface Format as the slot number/port number for the PE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 4
Choose the N-PE/U-PE Encapsulation type.
The choices are:
Note
•
FRAME RELAY
•
FRAME RELAY IETF
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 5
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 6
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Step 7
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 8
Click Finish.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-32
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an ATM Policy with a CE
Defining an ATM Policy with a CE
This section describes how to define an ATM policy with CE present. Figure 7-24 is an example of the
first page of this policy.
Figure 7-24
ATM Policy with a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-25 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Figure 7-25
ATM with CE Policy Attributes
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-33
Chapter 7
Creating an L2VPN Policy
Defining an ATM Policy with a CE
Step 2
Choose the Transport Mode from the drop-down list.
The choices are:
•
VP—Virtual path mode. This is the default.
•
VC—Virtual circuit mode.
•
PORT—Port mode. (Only supported for the IOS XR 3.7 platform.)
Note
Step 3
If you choose PORT as the transport mode, the attributes ATM VCD/Sub-interface # and
ATM VPI will be disabled in the Link Attributes window of the service request based on this
policy.
Choose the CE Interface Type from the drop-down list.
The choices are:
Step 4
•
ANY
•
ATM
•
Switch
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose a CE Encapsulation.
The choices are:
Note
•
AAL5SNAP
•
AAL5MUX
•
AAL5NLPID
•
AAL2
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is only applicable for IOS XR devices. If the check box is checked, an additional attribute,
PseudoWireClass, appears in the GUI. Click the Select button of PseudoWireClass attribute to choose
a pseudowire class previously created in ISC. The pseudowire class name is used for provisioning
pw-class commands on IOS XR devices. See Creating and Modifying Pseudowire Classes for IOS XR
Devices, page 2-10 for additional information on pseudowire class support for IOS XR devices.
Step 8
Choose an L2VPN Group Name from the drop-down list.
The choices are:
•
ISC
•
VPNSC
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-34
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an ATM Policy with a CE
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Note
Step 9
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the drop-down
list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
This attribute is only applicable for IOS XR devices. If no value is specified for the p2p name, ISC
generates a default name consisting of the names of the two PEs forming the pseudowire, separated by
hyphens (for example, 6503-A----6503-B). If the default name is more than 32 characters, the device
names are truncated.
Step 10
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Step 11
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 12
Click Finish.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-35
Chapter 7
Creating an L2VPN Policy
Defining an ATM Policy without a CE
Defining an ATM Policy without a CE
This section describes how to define an ATM policy without a CE present. Figure 7-26 is an example of
the first page of this policy.
Figure 7-26
ATM Policy without a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 7-27 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this L2VPN policy can modify the editable parameter during
L2VPN service request creation.
Figure 7-27
ATM without CE Policy Attributes
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-36
OL-21636-01
Chapter 7
Creating an L2VPN Policy
Defining an ATM Policy without a CE
Step 2
Choose the Transport Mode from the drop-down list.
The choices are:
•
VP—Virtual path mode. This is the default.
•
VC—Virtual circuit mode.
•
PORT—Port mode. (Only supported for the IOS XR 3.7 platform.)
Note
Step 3
If you choose PORT as the transport mode, the attributes ATM VCD/Sub-interface # and
ATM VPI will be disabled in the Link Attributes window of the service request based on this
policy.
Choose the N-PE/U-PE Interface Type from the drop-down list.
The choices are:
Step 4
•
ANY
•
ATM
•
Switch
Enter an Interface Format as the slot number/port number for the PE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose a PE Encapsulation.
The choices are:
Note
•
AAL5
•
AAL0
If the Interface Type is ANY, ISC will not ask for an Encapsulation type in the policy.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Use PseudoWireClass check box to enable the selection of a pseudowire class.
This attribute is only applicable for IOS XR devices. If the check box is checked, an additional attribute,
PseudoWireClass, appears in the GUI. Click the Select button of PseudoWireClass attribute to choose
a pseudowire class previously created in ISC. The pseudowire class name is used for provisioning
pw-class commands on IOS XR devices. See Creating and Modifying Pseudowire Classes for IOS XR
Devices, page 2-10 for additional information on pseudowire class support for IOS XR devices.
Step 8
Choose an L2VPN Group Name from the drop-down list.
The choices are:
•
ISC
•
VPNSC
This attribute is used for provisioning the L2VPN group name on IOS XR devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
7-37
Chapter 7
Creating an L2VPN Policy
Defining an ATM Policy without a CE
Note
Step 9
The choices in the drop-down list are derived from a configurable DCPL property. For
information about how to define the L2VPN Group Name choices available in the drop-down
list, see Defining L2VPN Group Names for IOS XR Devices, page 2-14.
Enter an E-Line Name to specify the point-to-point (p2p) E-line name.
This attribute is only applicable for IOS XR devices. If no value is specified for the p2p name, ISC
generates a default name consisting of the names of the two PEs forming the pseudowire, separated by
hyphens (for example, 6503-A----6503-B). If the default name is more than 32 characters, the device
names are truncated.
Step 10
Check the PW Tunnel Selection check box if you want to be able to manually select the Traffic
Engineering (TE) tunnel for the pseudowire connecting point-to-point N-PEs.
This attribute is unchecked by default
Subsequently, when you create a service request based on this policy, you must specify the TE tunnel ID
in a field provided. ISC uses the tunnel information to create and provision a pseudowire class that
describes the pseudowire connection between two N-PEs. This pseudowire class can be shared by more
than one pseudowire, as long as the pseudowires share the same tunnel ID and remote loopback address.
You are responsible to ensure that the tunnel interface and associated ID are configured. During service
request creation when you specify the tunnel ID number, ISC does not check the validity of the value.
That is, ISC does not verify the existence of the tunnel.
Step 11
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 12
Click Finish.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
7-38
OL-21636-01
CH A P T E R
8
Managing an L2VPN Service Request
This chapter covers the basic steps to provision an ERS (EVPL), EWS (EPL), ATM, or Frame Relay
L2VPN service. It contains the following sections:
•
Introducing L2VPN Service Requests, page 8-1
•
Creating an L2VPN Service Request, page 8-2
•
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request with a CE, page 8-2
•
Creating an EWS (EPL) L2VPN Service Request with a CE, page 8-8
•
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request without a CE, page 8-11
•
Creating an EWS (EPL) L2VPN Service Request without a CE, page 8-16
•
Modifying the L2VPN Service Request, page 8-20
•
Saving the L2VPN Service Request, page 8-26
Introducing L2VPN Service Requests
An L2VPN service request consists of one or more end-to-end wires, connecting various sites in a
point-to-point topology. When you create a service request, you enter several parameters, including the
specific interfaces on the CE and PE routers. You can also associate Cisco IP Solution Center (ISC)
templates and data files with a service request. See Appendix B, “Working with Templates and Data
Files,” for more about using templates and data files in service requests.
To create a service request, a Service Policy must already be defined, as described in Chapter 7,
“Creating an L2VPN Policy.”
Based on the predefined L2VPN policy, an operator creates an L2VPN service request, with or without
modifications to the L2VPN policy, and deploys the service. Service creation and deployment are
normally performed by regular network technicians for daily operation of network provisioning.
Note
Not all of the attributes defined in an L2VPN policy might be applicable to a service request. For specific
information, see L2VPN policy attribute descriptions in Chapter 7, “Creating an L2VPN Policy”.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-1
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
The following steps are involved in creating a service request for Layer 2 connectivity between customer
sites:
•
Choose a CE Topology for ERS (EVPL)/Frame Relay/ATM services.
•
Choose the endpoints (CE and PE) that must be connected. For each end-to-end Layer 2 connection,
ISC creates an end-to-end wire object in the repository for the service request.
•
Choose a CE or PE interface.
•
Choose a Named Physical Circuit (NPC) for the CE or PE.
•
Edit the end-to-end connection.
•
Edit the link attributes.
•
(0ptional) Associate templates and data files to devices in the service request.
Creating an L2VPN Service Request
To create an L2VPN service request, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manage > Service Requests.
The Service Requests window appears.
Step 2
Click Create.
Step 3
Choose L2VPN from the drop-down list.
L2VPN service requests must be associated with an L2VPN policy. You choose an L2VPN policy from
the policies previously created (see Chapter 7, “Creating an L2VPN Policy”).
Step 4
Choose the L2VPN policy of choice.
If more than one L2VPN policy exists, a list of L2VPN policies appears.
Step 5
When you make the choice, click OK.
As soon as you make the choice, the new service request inherits all the properties of that L2VPN policy,
such as all the editable and non-editable features and pre-set parameters.
To continue creating an L2VPN service request, go to one of the following sections:
•
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request with a CE, page 8-2.
•
Creating an EWS (EPL) L2VPN Service Request with a CE, page 8-8.
•
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request without a CE, page 8-11.
•
Creating an EWS (EPL) L2VPN Service Request without a CE, page 8-16.
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request with a CE
This section includes detailed steps for creating an L2VPN service request with a CE present for ERS
(EVPL), ATM, and Frame Relay policies. If you are creating an L2VPN service request for an EWS
(EPL) policy, go to Creating an EWS (EPL) L2VPN Service Request with a CE, page 8-8.
After you choose an L2VPN policy, the L2VPN Service Request Editor window appears. (See
Figure 8-1.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-2
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-1
L2VPN Service Request Editor
Perform the following steps.
Step 1
Choose a Topology from the drop-down list. If you choose Full Mesh, each CE will have direct
connections to every other CE.
If you choose Hub and Spoke, then only the Hub CE has connection to each Spoke CE and the Spoke
CEs do not have direct connection to each other.
Note
Step 2
The full mesh and the hub and spoke topologies make a difference only when you choose more
than two endpoints. For example, with four endpoints, ISC automatically creates six links with
full mesh topology. With hub and spoke topology, however, ISC creates only three links.
Click Add Link.
You specify the CE endpoints using the Attachment Tunnel Editor. You can create one or more CEs from
a window like the one in Figure 8-2.
Figure 8-2
Note
Select CE
All the services that deploy point-to-point connections (ERS/EVPL, EWS/EPL, ATMoMPLS,
and FRoMPLS) must have at least two CEs specified.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-3
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Step 3
Click Select CE in the CE column.
The CPE for Attachment Circuit window appears. (See Figure 8-3.) This window displays the list of
currently defined CEs.
a.
From the Show CPEs with drop-down list, you can display CEs by Customer Name, by Site, or by
Device Name.
b.
You can use the Find button to either search for a specific CE, or to refresh the display.
c.
You can set the Rows per page to 5, 10, 20, 30, 40, or All.
Figure 8-3
Select CPE Device
Step 4
In the Select column, choose a CE for the L2VPN link.
Step 5
Click Select.
The Service Request Editor window appears displaying the name of the selected CE in the CE column.
Step 6
Choose the CE interface from the drop-down list. (See Figure 8-4.)
Figure 8-4
Note
Select the CE Interface
When you provision an L2VPN ERS (EVPL) service, when you choose a UNI for a particular device,
ISC determines if there are other services using the same UNI. If so, a warning message is displayed. If
you ignore the message and save the service request, all of the underlying service requests relying on the
same UNI are synchronized with the modified shared attributes of the latest service request. In addition,
the state of the existing service requests is changed to the Requested state.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-4
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Note
ISC only displays the available interfaces for the service, based on the configuration of the underlying
interfaces, existing service requests that might be using the interface, and the customer associated with
the service request. You can click the Details button to display a pop-up window with information on
the available interfaces, such as interface name, customer name, VPN name and service request ID,
service request type, VLAN translation type, and VLAN ID information.
Step 7
If only one NPC exists for the Chosen CE and CE interface, that NPC is autopopulated in the Circuit
Selection column and you need not choose it explicitly. If more then one NPC is available, click Select
one circuit in the Circuit Selection column.
The NPC window appears, enabling you to choose the appropriate NPC.
Step 8
Click OK.
Each time you choose a CE and its interface, the NPC that was precreated from this CE and interface is
automatically displayed under Circuit Selection. (See Figure 8-5.) This means that you do not have to
further specify the PE to complete the link.
Figure 8-5
NPC Created
If you want to review the details of this NPC, click Circuit Details in the Circuit Details column. The
NPC Details window appears and lists the circuit details for this NPC.
Step 9
Continue to specify additional CEs, as in previous steps.
ISC creates the links between CEs based on the Topology that you chose.
Step 10
Click OK in Figure 8-6.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-5
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-6
NPCs Created
For ERS (EVPL), ATM, and Frame Relay, the End-to-End Wire Editor window appears. (See
Figure 8-7.)
Figure 8-7
Step 11
End-to-End Wire Editor
The VPN for this service request appears in the VPN field.
If there is more than one VPN, click Select VPN to choose a VPN. The VPN for L2VPN service request
window appears.
Step 12
Choose a VPN Name and click Select.
The L2VPN Service Request Editor window appears with the VPN name displayed.
Step 13
If necessary, click Add AC in the Attachment Circuit AC2 column, and repeat Steps 3 to 10 for AC2.
The End-to-End Wire Editor window displays the complete end-to-end wire. (See Figure 8-8.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-6
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-8
Step 14
Step 15
End-to-End Wire Created
Specify remaining items in the End-to-End-Wire Editor window as necessary for your configuration:
•
You can choose any of the blue highlighted values to edit the End-to-End Wire.
•
You can edit the AC link attributes to change the default policy settings. After you edit these fields,
the blue link changes from Default to Changed. For more information, see the section Modifying the
L2VPN Service Request, page 8-20.
•
You can enter a description for the service request in the first Description field. The description will
show up in this window and also in the Description column of the Service Requests window. The
maximum length for this field is 256 characters.
•
You can enter a description for each end-to-end wire in the Description field provided for each wire.
The description shows up only in this window. The data in this field is not pushed to the device(s).
The maximum length for this field is 256 characters.
•
The ID number is system-generated identification number for the circuit.
•
The Circuit ID is created automatically, based on the service. For example, for Ethernet, it is based
on the VLAN number; for Frame Relay, it is based on the DLCI; for ATM, it is based on the
VPI/VCI.
•
If the policy was set up for you to define a VC ID manually, enter it into the empty VC ID field. If
policy was set to “auto pick” the VC ID, ISC will supply a VC ID, and this field will not be editable.
In the case where you supply the VC ID manually, if the entered value is in the provider’s range,
ISC validates if the entered value is available or allocated. If the entered value has been already
allocated, ISC generates an error message saying that the entered value is not available and prompts
you to re-enter the value. If the entered value is in the provider’s range, and if it is available, then it
is allocated and is removed from the VC ID pool. If the entered value is outside the provider’s range,
ISC displays a warning saying that no validation could be performed to verify if it is available or
allocated.
•
You can also click Add Link to add an end-to-end wire.
•
You can click Delete Link to delete an end-to-end wire.
When you are finished editing the end-to-end wires, click Save.
The service request is created and saved into ISC.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-7
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Creating an EWS (EPL) L2VPN Service Request with a CE
This section includes detailed steps for creating an L2VPN service request with a CE present for EWS
(EPL). If you are creating an L2VPN service request for an ERS (EVPL), ATM, or Frame Relay policy,
go to Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request with a CE, page 8-2.
Perform the following steps.
Step 1
Create the L2VPN service request for EWS (EPL) with CE.
The L2VPN Service Request Editor window appears. (See Figure 8-9.)
Figure 8-9
Step 2
EWS (EPL) Service Request Editor
Click Select VPN to choose a VPN for use with this CE.
The Select VPN window appears with the VPNs defined in the system.
Step 3
Choose a VPN Name in the Select column.
Step 4
Click Select.
The L2VPN Service Request Editor window appears with the VPN name displayed.
Step 5
Click Add Link. (See Figure 8-10.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-8
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-10
Step 6
End-To-End Wire Editor
•
You can enter a description for the service request in the first Description field. The description will
show up in this window and also in the Description column of the Service Requests window. The
maximum length for this field is 256 characters.
•
You can enter a description for each end-to-end wire in the Description field provided for each wire.
The description shows up only in this window. The data in this field is not pushed to the device(s).
The maximum length for this field is 256 characters.
•
The ID number is system-generated identification number for the circuit.
•
The Circuit ID is created automatically, based on the service. For example, for Ethernet, it is based
on the VLAN number; for Frame Relay, it is based on the DLCI; for ATM, it is based on the
VPI/VCI.
Click Add AC in the Attachment Circuit (A1) column.
The Attachment Tunnel Editor appears. (See Figure 8-11.)
Figure 8-11
Step 7
Select CE for Attachment Circuit
Click Select CE.
The Select CPE window appears. (See Figure 8-12.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-9
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-12
CPE for Attachment Circuit
This window displays the list of currently defined CEs.
a.
From the Show CPEs with drop-down list, you can display CEs by Customer Name, by Site, or by
Device Name.
b.
You can use the Find button to either search for a specific CE, or to refresh the display.
c.
You can set the Rows per page to 5, 10, 20, 30, 40, or All.
Step 8
In the Select column, choose a CE for the L2VPN link.
Step 9
Click Select.
Step 10
In the Attachment Tunnel Editor window, choose a CE interface from the drop-down list.
Step 11
If only one NPC exists for the Chosen CE and CE interface, that NPC is autopopulated in the Circuit
Selection column and you need not choose it explicitly.
If more then one NPC is available, click Select one circuit in the Circuit Selection column. The NPC
window appears, enabling you to choose the appropriate NPC. Each time you choose a CE and its
interface, the NPC that was precreated from this CE and interface is automatically displayed under
Circuit Selection. This means that you do not have to further specify the PE to complete the link.
Step 12
Click OK.
The EndToEndWire Editor window appears displaying the name of the selected CE in the AC1 column.
(See Figure 8-13.)
Figure 8-13
NPC Created
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-10
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Step 13
Click AC1 Link Attributes and edit the attributes if desired.
For more information, see the section Modifying the L2VPN Service Request, page 8-20.
Step 14
Click OK.
Step 15
Repeat Steps 6 through 14 for AC2.
Step 16
Click OK.
You see a window like Figure 8-14.
Figure 8-14
Step 17
Attachment Circuits Selected
Click Save.
The EWS (EPL) service request is created and saved in ISC.
Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request without a
CE
This section includes detailed steps for creating an L2VPN service request without a CE present for ERS
(EVPL), ATM, and Frame Relay policies. If you are creating an L2VPN service request for an EWS
(EPL) policy, go to Creating an EWS (EPL) L2VPN Service Request without a CE, page 8-16.
Perform the following steps.
Step 1
Create the L2VPN service request for ERS (EVPL) without a CE.
The L2VPN Service Request Editor window appears. (See Figure 8-15.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-11
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-15
Step 2
L2VPN Service Request Editor
Choose a Topology from the drop-down list.
If you choose Full Mesh, each CE will have direct connections to every other CE. If you choose Hub
and Spoke, then only the Hub CE has connection to each Spoke CE and the Spoke CEs do not have direct
connection to each other.
Note
Step 3
The full mesh and the hub and spoke topologies make a difference only when you choose more
than two endpoints. For example, with four endpoints, ISC automatically creates six links with
full mesh topology. With hub and spoke topology, however, ISC creates only three links.
Click Add Link.
The Attachment Tunnel Editor window appears. (See Figure 8-16.)
Figure 8-16
Select U-PE/PE-AGG/N-PE
Step 4
Specify the N-PE/PE-AGG/U-PE endpoints using the Attachment Tunnel Editor, as covered in the
following steps.
Step 5
Click Select U-PE/PE-AGG/N-PE in the U-PE/PE-AGG/N-PE column.
The PE for Attachment Circuit window appears. (See Figure 8-17).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-12
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-17
Select PE Device
This window displays the list of currently defined PEs.
a.
The Show PEs with drop-down list shows PEs by customer name, by site, or by device name.
b.
The Find button allows a search for a specific PE or a refresh of the window.
c.
The Rows per page drop-down list allows the page to be set to 5, 10, 20, 30, 40, or All.
Step 6
In the Select column, choose the PE device name for the L2VPN link.
Step 7
Click Select.
The Service Request Editor window appears displaying the name of the selected PE in the PE column.
(See Figure 8-18.)
Figure 8-18
Step 8
Note
Select the UNI Interface
Choose the UNI interface from the drop-down list.
When you provision an L2VPN ERS (EVPL) service, when you choose a UNI for a particular device,
ISC determines if there are other services using the same UNI. If so, a warning message is displayed. If
you ignore the message and save the service request, all of the underlying service requests lying on the
same UNI are synchronized with the modified shared attributes of the latest service request. In addition,
the state of the existing service requests is changed to the Requested state.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-13
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Note
Step 9
ISC only displays the available interfaces for the service, based on the configuration of the underlying
interfaces, existing service requests that might be using the interface, and the customer associated with
the service request. You can click the Details button to display a pop-up window with information on
the available interfaces, such as interface name, customer name, VPN name and service request ID,
service request type, VLAN translation type, and VLAN ID information.
If the PE role type is U-PE, click Select one circuit in the Circuit Selection column.
The NPC window appears. (See Figure 8-19.)
Figure 8-19
Select NPC
If only one NPC exists for the Chosen PE and PE interface, that NPC is auto populated in the Circuit
Selection column and you need not choose it explicitly.
Note
If the PE role type is N-PE, the columns Circuit Selection and Circuit Details are disabled.
Step 10
Choose the name of the NPC from the Select column.
Step 11
Click OK.
Each time you choose a PE and its interface, the NPC that was precreated from this PE and interface is
automatically displayed under Circuit Selection. (See Figure 8-20.) This means that you do not have to
further specify the PE to complete the link.
Figure 8-20
Step 12
NPC Created
If you want to review the details of this NPC, click Circuit Details in the Circuit Details column.
The NPC Details window appears and lists the circuit details for this NPC.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-14
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Step 13
After you specify all the PEs, ISC creates the links between PEs based on the Topology that you chose.
Step 14
Click OK.
For ERS (EVPL), ATM, and Frame Relay, the End-to-End-Wire Editor window appears. (See
Figure 8-21.)
Figure 8-21
Step 15
End-to-End Wire Editor
The VPN for this service request appears in the Select VPN field.
If there is more than one VPN, click Select VPN to choose a VPN.
Step 16
Specify remaining items in the End-to-End-Wire Editor window, as necessary for your configuration:
•
You can choose any of the blue highlighted values to edit the End-to-End Wire.
•
You can edit the AC link attributes to change the default policy settings. After you edit these fields,
the blue link changes from Default to Changed. For more information, see the section Modifying the
L2VPN Service Request, page 8-20.
•
You can also click Add Link to add an end-to-end wire.
•
You can click Delete Link to delete an end-to-end wire.
Note
If you are attempting to decommission a service request to which a template has been added, see
Monitoring Service Requests, page 11-10 for information on the proper way to do this.
•
You can enter a description for the service request in the first Description field. The description will
show up in this window and also in the Description column of the Service Requests window. The
maximum length for this field is 256 characters.
•
You can enter a description for each end-to-end wire in the Description field provided for each wire.
The description shows up only in this window. The data in this field is not pushed to the device(s).
The maximum length for this field is 256 characters.
•
The ID number is system-generated identification number for the circuit.
•
The Circuit ID is created automatically, based on the service. For example, for Ethernet, it is based
on the VLAN number; for Frame Relay, it is based on the DLCI; for ATM, it is based on the
VPI/VCI.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-15
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Step 17
When you are finished editing the end-to-end wires, click Save.
The service request is created and saved into ISC.
Creating an EWS (EPL) L2VPN Service Request without a CE
This section includes detailed steps for creating an L2VPN service request without a CE present for EWS
(EPL). If you are creating an L2VPN service request for an ERS (EVPL), ATM, or Frame Relay policy,
see Creating an ERS (EVPL), ATM, or Frame Relay L2VPN Service Request without a CE, page 8-11.
Step 1
Create the L2VPN service request for EWS (EPL) without a CE.
The L2VPN Service Request Editor window appears. (See Figure 8-22.)
Figure 8-22
Step 2
EWS (EPL) Service Request Editor
Click Select VPN to choose a VPN for use with this PE.
The Select a VPN window appears with the VPNs defined in the system.
Step 3
Choose a VPN Name in the Select column.
Step 4
Click Select.
The End-To-End Wire Editor window appears with the VPN name displayed. (See Figure 8-23.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-16
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-23
Step 5
End-To-End Wire Editor
Click Add AC in the Attachment Circuit (AC1) column.
The Attachment Tunnel Editor window appears. (See Figure 8-24.)
Figure 8-24
Step 6
Select the PE for the Attachment Circuit
Click Select N-PE/PE-AGG/U-PE.
The Select PE Device window appears. (See Figure 8-25.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-17
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Figure 8-25
PE for Attachment Circuit
This window displays the list of currently defined PEs.
a.
From the Show PEs with drop-down list, you can display PEs by Customer Name, by Site, or by
Device Name.
b.
You can use the Find button to either search for a specific PE, or to refresh the display.
c.
You can set the Rows per page to 5, 10, 20, 30, 40, or All.
Step 7
In the Select column, choose a PE for the L2VPN link.
Step 8
Click Select.
The Attachment Tunnel Editor window appears. (See Figure 8-26.)
Figure 8-26
Step 9
Note
PE Interface
Choose a PE interface from the drop-down list.
ISC only displays the available interfaces for the service, based on the configuration of the underlying
interfaces, existing service requests that might be using the interface, and the customer associated with
the service request. You can click the Details button to display a pop-up window with information on
the available interfaces, such as interface name, customer name, VPN name and service request ID,
service request type, VLAN translation type, and VLAN ID information.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-18
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Creating an L2VPN Service Request
Step 10
If the PE role type is N-PE, the columns Circuit Selection and Circuit Details are disabled. In this case,
skip to Step 13.
Step 11
If the PE role type is U-PE, click Select one circuit in the Circuit Selection column.
The Select NPC window appears. (See Figure 8-27.)
Figure 8-27
Note
Select NPC
If only one NPC exists for the Chosen PE and PE interface, that NPC is auto populated in the Circuit
Selection column and you need not choose it explicitly.
Step 12
If applicable, choose the name of the NPC from the Select column.
Step 13
Click OK.
The Attachment Tunnel Editor appears. (See Figure 8-28.)
Figure 8-28
Note
Step 14
NPC Created
Each time you choose a PE and its interface, the NPC that was precreated from this PE and interface is
automatically displayed under Circuit Selection. (See Figure 8-28.) This means that you do not have to
further specify the PE to complete the link.
Click OK.
The Service Request Editor window appears displaying the name of the selected PE in the AC1 column.
(See Figure 8-29.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-19
Chapter 8
Managing an L2VPN Service Request
Modifying the L2VPN Service Request
Figure 8-29
Step 15
Attachment Circuit Selected
Click AC1 Link Attributes and edit the attributes, if desired.
For more information, see the section Modifying the L2VPN Service Request, page 8-20.
Step 16
Repeat Steps 5 through 14 for AC2.
Step 17
Specify remaining items in the End-to-End-Wire Editor window, as necessary for your configuration.
Step 18
•
You can enter a description for the service request in the first Description field. The description will
show up in this window and also in the Description column of the Service Requests window. The
maximum length for this field is 256 characters.
•
You can enter a description for each end-to-end wire in the Description field provided for each wire.
The description shows up only in this window. The data in this field is not pushed to the device(s).
The maximum length for this field is 256 characters.
•
The ID number is system-generated identification number for the circuit.
•
The Circuit ID is created automatically, based on the service. For example, for Ethernet, it is based
on the VLAN number; for Frame Relay, it is based on the DLCI; for ATM, it is based on the
VPI/VCI.
Click Save.
The EWS (EPL) service request is created and saved in ISC.
Modifying the L2VPN Service Request
This section describes how to edit the L2VPN service request attributes. This is also where you can
associate templates and data files to devices that are part of the ACs.
Perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests. (See
Figure 8-30.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-20
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Modifying the L2VPN Service Request
Figure 8-30
L2VPN Service Activation
Step 2
Check a check box for a service request.
Step 3
Click Edit.
The End-to-End-Wire Editor window appears. (See Figure 8-31.)
Figure 8-31
Step 4
End-to-End Wire Editor
Modify any of the attributes, as desired:
•
The VPN for this service request appears in the Select VPN field. If this request has more than one
VPN, click Select VPN to choose a VPN.
•
You can choose any of the blue highlighted values to edit the End-to-End Wire.
•
You can edit the AC link attributes to change the default policy settings. After you edit these fields,
the blue link changes from Default to Changed.
•
You can enter a description for the service request in the first Description field. The description will
show up in this window and also in the Description column of the Service Requests window. The
maximum length for this field is 256 characters.
•
You can enter a description for each end-to-end wire in the Description field provided for each wire.
The description shows up only in this window. The data in this field is not pushed to the device(s).
The maximum length for this field is 256 characters.
•
The Circuit ID is created automatically, based on the VLAN data for the circuit.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-21
Chapter 8
Managing an L2VPN Service Request
Modifying the L2VPN Service Request
•
If the policy was set up for you to define a VC ID manually, enter it into the empty VC ID field. If
policy was set to “auto pick” the VC ID, ISC will supply a VC ID, and this field will not be editable.
In the case where you supply the VC ID manually, if the entered value is in the provider’s range,
ISC validates if the entered value is available or allocated. If the entered value has been already
allocated, ISC generates an error message saying that the entered value is not available and prompts
you to re-enter the value. If the entered value is in the provider’s range, and if it is available, then it
is allocated and is removed from the VC ID pool. If the entered value is outside the provider’s range,
ISC displays a warning saying that no validation could be performed to verify if it is available or
allocated.
•
You can also click Add Link to add an end-to-end wire.
•
You can click Delete Link to delete an end-to-end wire.
Note
Step 5
If you are attempting to decommission a service request to which a template has been added, see
Monitoring Service Requests, page 11-10 for information on the proper way to do this.
•
The ID number is system-generated identification number for the circuit.
•
The Circuit ID is created automatically, based on the service. For example, for Ethernet, it is based
on the VLAN number; for Frame Relay, it is based on the DLCI; for ATM, it is based on the
VPI/VCI.
To edit AC attributes, click the Default button.
The Link Attributes window appears. (See Figure 8-32.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-22
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Modifying the L2VPN Service Request
Figure 8-32
Link Attributes Window
Step 6
Edit any of the link attributes, as desired.
Step 7
To add a template and data file to an attachment circuit, choose a Device Name, and click Add under
Templates.
The Add/Remove Templates window appears. (See Figure 8-33.)
Note
To add a template to an attachment circuit, you must have already created the template. For
detailed steps to create templates, see the Cisco IP Solution Center Infrastructure Reference, 6.0.
For more information on how to use templates and data files in service requests, see Appendix B,
“Working with Templates and Data Files.”
Figure 8-33
Step 8
Add/Remove Templates
Click Add.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-23
Chapter 8
Managing an L2VPN Service Request
Modifying the L2VPN Service Request
The Template Data File Chooser window appears. (See Figure 8-34.)
Figure 8-34
Step 9
Template Datafile Chooser
In the left pane, navigate to and select a template.
The associated data files are listed in rows in the main window, as shown in Figure 8-34.
Step 10
Check the data file that you want to add and click Accept.
The Add/Remove Templates window appears with the template displayed. (See Figure 8-35.)
Figure 8-35
Add/Remove Templates with Templates Shown
Step 11
Choose a Template name.
Step 12
Under Action, use the drop-down list and choose APPEND or PREPEND.
Append tells ISC to append the template generated CLI to the regular ISC (non-template) CLI. Prepend
is the reverse and does not append the template to the ISC CLI.
Step 13
Choose Active to use this template for this service request.
If you do not choose Active, the template is not used.
Step 14
Click OK.
The Link Attributes with the template added appears. (See Figure 8-36.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-24
OL-21636-01
Chapter 8
Managing an L2VPN Service Request
Modifying the L2VPN Service Request
Figure 8-36
Note
Step 15
Link Attributes with Template Added
For more information about using templates and data files in service requests, see Appendix B,
“Working with Templates and Data Files.”
Click OK.
The Service Request Editor window appears showing the default for AC1 changed. (See Figure 8-37.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
8-25
Chapter 8
Managing an L2VPN Service Request
Saving the L2VPN Service Request
Figure 8-37
Step 16
Service Request Editor with Link Attributes Changed.
When you are finished editing the end-to-end wires, click Save.
Saving the L2VPN Service Request
To save an L2VPN service request, perform the following steps.
Step 1
When you are finished with Link Attributes for all the Attachment Circuits, click Save to finish the
L2VPN service request creation. If the L2VPN service request is successfully created, you will see the
service request list window. (See Figure 8-38.) The newly created L2VPN service request is added with
the state of REQUESTED, as shown in the figure.
Figure 8-38
Step 2
L2VPN Service Request Created
If, however, the L2VPN service request creation failed for some reason (for example, a value chosen is
out of bounds), you are warned with an error message. In such a case, you should correct the error and
save the service request again.
For information on deploying L2VPN service requests, see Deploying Service Requests, page 11-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
8-26
OL-21636-01
CH A P T E R
9
Creating a VPLS Policy
This chapter contains the basic steps to create a VPLS policy. It contains the following sections:
•
Defining a VPLS Policy, page 9-1
•
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE, page 9-3
•
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE, page 9-7
•
Defining an MPLS/EMS (EP-LAN) Policy with a CE, page 9-11
•
Defining an MPLS/EMS (EP-LAN) Policy without a CE, page 9-16
•
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE, page 9-22
•
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE, page 9-27
•
Defining an Ethernet/EMS (EP-LAN) Policy with a CE, page 9-32
•
Defining an Ethernet/EMS (EP-LAN) Policy without a CE, page 9-37
Defining a VPLS Policy
You must define a VPLS policy before you can provision a service. A VPLS policy defines the common
characteristics shared by the Attachment Circuit (AC) attributes.
A policy can be shared by one or more service requests that have similar service requirements. The
Editable check box gives the network operator the option of making a field editable. If the value is set
to editable, the service request creator can change to other valid values for the particular policy item. If
the value is not set to editable, the service request creator cannot change the policy item.
You can also associate Cisco IP Solution Center (ISC) templates and data files with a service request.
See Appendix B, “Working with Templates and Data Files,” for more about using templates and data
files in service requests.
VPLS policies correspond to the one of the core types that VPLS provides:
•
MPLS core type—provider core network is MPLS enabled
•
Ethernet core type—provider core network uses Ethernet switches
and to one of the service types that VPLS provides:
•
Ethernet Relay Multipoint Service (ERMS). The Metro Ethernet Forum name for ERMS is Ethernet
Virtual Private LAN (EVP-LAN). See Layer 2 Terminology Conventions, page E-1 for more
information about terms used to denote VPLS services in this guide.
•
Ethernet Multipoint Service (EMS). The MEF name for EMS is Ethernet Private LAN (EP-LAN).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-1
Chapter 9
Creating a VPLS Policy
Defining a VPLS Policy
A policy is a template of most of the parameters needed to define a VPLS service request. After you
define it, a VPLS policy can be used by all the VPLS service requests that share a common set of
characteristics.
You create a new VPLS policy whenever you create a new type of service or a service with different
parameters. VPLS policy creation is normally performed by experienced network engineers.
To define a VPLS policy in the Cisco IP Solution Center (ISC), perform the following steps.
Step 1
Choose Service Design > Policies.
The Policies window appears.
Step 2
Click Create.
Step 3
Choose VPLS Policy.
The VPLS Policy Editor window appears. (See Figure 9-1.)
Figure 9-1
Creating a VPLS Policy
Step 4
Enter a Policy Name for the VPLS policy.
Step 5
Choose the Policy Owner for the VPLS policy.
There are three types of VPLS policy ownership:
•
Customer ownership
•
Provider ownership
•
Global ownership—Any service operator can make use of this VPLS policy.
This ownership has relevance when the ISC Role-Based Access Control (RBAC) comes into play. For
example, a VPLS policy that is customer owned can only be seen by operators who are allowed to work
on this customer-owned policy.
Similarly, operators who are allowed to work on a provider’s network can view, use, and deploy a
particular provider-owned policy.
Step 6
Click Select to choose the owner of the VPLS policy.
The policy owner was established when you created customers or providers during ISC setup. If the
ownership is global, the Select function does not appear.
Step 7
Choose the Core Type of the VPLS policy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-2
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE
There are two core types for VPLS policies:
Step 8
•
MPLS—running on an IP network
•
Ethernet—all PEs are on an Ethernet provider network
Choose the Service Type of the VPLS policy.
There are two service types for VPLS policies:
Step 9
•
Ethernet Relay Multipoint Service (ERMS). (The MEF name for ERMS is EVP-LAN.)
•
Ethernet Multipoint Service (EMS). (The MEF name for EMS is EP-LAN.)
Check the CE Present check box if you want ISC to ask the service operator who uses this VPLS policy
to provide a CE router and interface during service activation.
The default is CE present in the service.
If you do not check the CE Present check box, ISC asks the service operator, during service activation,
only for the PE router and customer-facing interface.
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE
This section describes how to define a VPLS policy with an MPLS core type and an ERMS (EVP-LAN)
service type with CE present. Figure 9-2 is an example of the first page of this policy.
Figure 9-2
MPLS/ERMS (EVP-LAN) Policy with a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 9-3 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-3
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE
Figure 9-3
Step 2
MPLS/ERMS (EVP-LAN) with a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a CE, N-PE, PE-AGG, or U-PE interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-4
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 4
Choose a CE Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Step 5
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 6
Check UNI Shutdown box if you want to leave the UNI port shut during service activation, for example,
when the service provider wants to deploy a service in the network but wants to activate it at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Choose a Port Type.
The choices are:
•
Access Port
•
Trunk with Native VLAN
Step 12
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 13
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 14
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B
ERMS (EVP-LAN) Service.
Step 15
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 16
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-5
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy with a CE
Step 17
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the Filter BPDU check box to specify that the UNI port should not process Layer 2 Bridge
Protocol Data Units (BPDUs).
Step 21
Check the UNI Port Security check box (see Figure 9-4) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses. Click the Edit
button to enter the addresses.
Figure 9-4
Step 22
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-5) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-6
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE
Figure 9-5
Step 23
Enable Storm Control
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE
This section describes defining a VPLS policy with an MPLS core type and an ERMS (EVP-LAN)
service type without a CE present. Figure 9-6 is an example of the first page of this policy.
Figure 9-6
MPLS/ERMS (EVP-LAN) Policy without a CE
Perform the following steps.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-7
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE
Step 1
Click Next. The window in Figure 9-7 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Figure 9-7
Step 2
MPLS/ERMS (EVP-LAN) without a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Check the Standard UNI Port check box to enable port security.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-8
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 4
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose a CE Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Step 6
Check UNI Shutdown box if you want to leave the UNI port shut during service activation, for example,
when the service provider wants to deploy a service in the network but wants to activate it at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy). This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Choose a Port Type.
The choices are:
•
Access Port
•
Trunk with Native VLAN
Step 12
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 13
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 14
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B
ERMS (EVP-LAN) Service.
Step 15
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 16
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-9
Chapter 9
Creating a VPLS Policy
Defining an MPLS/ERMS (EVP-LAN) Policy without a CE
Step 17
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the Filter BPDU check box to specify that the UNI port should not process Layer 2 Bridge
Protocol Data Units (BPDUs).
Step 21
Check the UNI Port Security check box (see Figure 9-8) if you to want to provision port security-related
CLIs to the UNI port by controlling the MAC addresses that are allowed to go through the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 9-8
Step 22
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-9) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-10
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy with a CE
Figure 9-9
Step 23
Enable Storm Control
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Defining an MPLS/EMS (EP-LAN) Policy with a CE
This section describes defining a VPLS policy with an MPLS core type and an EMS (EP-LAN) service
type with CE present. Figure 9-10 is an example of the first page of this policy.
Figure 9-10
MPLS/EMS (EP-LAN) Policy with a CE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-11
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy with a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 9-11 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Figure 9-11
Step 2
MPLS/EMS (EP-LAN) with a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a CE, N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-12
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy with a CE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 4
Choose a CE Encapsulation type.
The choices are:
Note
Step 5
•
DOT1Q
•
DEFAULT
When creating a service request based on the MPLS/EMS (EP-LAN) with CE policy, the Encapsulation
attribute is ignored. Therefore, setting this value has no effect.
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy). This check box is checked by default.
Step 9
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 10
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 11
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 12
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 13
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B EMS
(EP-LAN) Service.
Step 14
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-13
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy with a CE
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Step 16
Enter the System MTU in bytes.
The maximum transmission unit (MTU) size is configurable and optional. ISC does not perform an
integrity check for this customized value. If a service request goes to the Failed Deploy state because
this size is not accepted, you must adjust the size until the service request is deployed. ISC supports,
ranges for different platforms, as specified below. The range is 1500 to 9216.
Step 17
•
For the 3750 and 3550 platforms, the MTU range is 1500-1546.
•
For the 7600 ethernet port, the MTU size is always 9216. Even with the same platform and same
IOS release, different line cards support the MTU differently. For example, older line cards only take
an MTU size of 9216 and newer cards support 1500-9216. However, ISC uses 9216 in both cases.
•
For the 7600 SVI (interface VLAN), the MTU size is 1500-9216.
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the UNI Port Security check box (see Figure 9-12) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-14
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy with a CE
Figure 9-12
Step 21
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-13) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 9-13
Step 22
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 9-14) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 9-14
Protocol Tunnelling
For each protocol that you check, enter the shutdown threshold and drop threshold for that protocol:
a.
Tunnel CDP—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
CDP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-15
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy without a CE
Step 23
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Tunnel VTP—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
VTP threshold—Enter the number of packets per second to be received before the interface is shut
down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Tunnel STP—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
STP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Defining an MPLS/EMS (EP-LAN) Policy without a CE
This section describes defining a VPLS policy with an MPLS core type and an EMS (EP-LAN) service
type without a CE present. Figure 9-15 is an example of the first page of this policy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-16
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy without a CE
Figure 9-15
MPLS/EMS (EP-LAN) Policy without a CE
Perform the following steps.
Step 1
Click Next. The window in Figure 9-16 appears.
The Editable check box gives you the option of making a field editable. If you check Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-17
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy without a CE
Figure 9-16
Step 2
MPLS/EMS (EP-LAN) without a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-18
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy without a CE
Step 4
Enter an Interface Format as the slot number/port number for the PE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose a N-PE/U-PE Encapsulation type.
The choices are:
Note
•
DOT1Q
•
DEFAULT
When creating a service request based on the MPLS/EMS (EP-LAN) without CE policy, the
Encapsulation attribute is ignored. Therefore, setting this value has no effect.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy). This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 12
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 13
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B EMS
(EP-LAN) Service.
Step 14
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Step 16
Enter the System MTU in bytes.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-19
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy without a CE
The maximum transmission unit (MTU) size is configurable and optional. ISC does not perform an
integrity check for this customized value. If a service request goes to the Failed Deploy state because
this size is not accepted, you must adjust the size until the service request is deployed. ISC supports,
ranges for different platforms, as specified below. The range is 1500 to 9216.
Step 17
•
For the 3750 and 3550 platforms, the MTU range is 1500-1546.
•
For the 7600 ethernet port, the MTU size is always 9216. Even with the same platform and same
IOS release, different line cards support the MTU differently. For example, older line cards only take
an MTU size of 9216 and newer cards support 1500-9216. However, ISC uses 9216 in both cases.
•
For the 7600 SVI (interface VLAN), the MTU size is 1500-9216.
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the UNI Port Security check box (see Figure 9-17) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-20
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an MPLS/EMS (EP-LAN) Policy without a CE
Figure 9-17
Step 21
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-18) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 9-18
Step 22
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 9-19) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 9-19
Protocol Tunnelling
For each protocol that you check, enter the shutdown threshold and drop threshold for that protocol:
a.
Tunnel CDP—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
CDP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-21
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
Step 23
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Tunnel VTP—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
VTP threshold—Enter the number of packets per second to be received before the interface is shut
down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Tunnel STP—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
STP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
This section describes defining a VPLS policy with an Ethernet core type and an ERMS (EVP-LAN)
service type with CE present. Figure 9-20 is an example of the first page of this policy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-22
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
Figure 9-20
Ethernet/ERMS (EVP-LAN) Policy with a CE
Perform the following steps.
Step 1
Click Next.
The window in Figure 9-21 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-23
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
Figure 9-21
Step 2
Ethernet ERMS (EVP-LAN) with a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a CE, N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-24
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
Step 4
Choose a CE Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Step 5
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Choose a Port Type.
The choices are:
•
Access Port
•
Trunk with Native VLAN
Step 12
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 13
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 14
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B
ERMS (EVP-LAN) Service.
Step 15
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 16
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-25
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy with a CE
Step 17
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the Filter BPDU check box to specify that the UNI port should not process Layer 2 Bridge
Protocol Data Units (BPDUs).
Step 21
Check the UNI Port Security check box (see Figure 9-22) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 9-22
Step 22
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-22) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-26
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
Figure 9-23
Step 23
Enable Storm Control
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
This section describes defining a VPLS policy with an Ethernet core type and an ERMS (EVP-LAN)
service type without a CE present. Figure 9-24 is an example of the first page of this policy.
Figure 9-24
Ethernet/ERMS (EVP-LAN) Policy without a CE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-27
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
Perform the following steps.
Step 1
Click Next.
The window in Figure 9-25 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Figure 9-25
Step 2
Ethernet/ERMS (EVP-LAN) without a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a CE, N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-28
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 4
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose a CE Encapsulation type.
The choices are:
•
DOT1Q
•
DEFAULT
If DEFAULT is the CE encapsulation type, ISC shows another field for the UNI port type.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy). This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Choose a Port Type.
The choices are:
•
Access Port
•
Trunk with Native VLAN
Step 12
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 13
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 14
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B
ERMS (EVP-LAN) Service.
Step 15
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-29
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
Step 16
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Step 17
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the Filter BPDU check box to specify that the UNI port should not process Layer 2 Bridge
Protocol Data Units (BPDUs).
Step 21
Check the UNI Port Security check box (see Figure 9-26) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 9-26
Step 22
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-27) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-30
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/ERMS (EVP-LAN) Policy without a CE
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 9-27
Step 23
Enable Storm Control
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-31
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
This section describes defining a VPLS policy with an Ethernet core type and an EMS (EP-LAN) service
type with a CE present. Figure 9-28 is an example of the first page of this policy.
Figure 9-28
Ethernet/EMS (EP-LAN) Policy with CE Present
Perform the following steps.
Step 1
Click Next.
The window in Figure 9-29 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-32
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
Figure 9-29
Step 2
Ethernet/EMS (EP-LAN) with a CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a CE, N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design.
The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-33
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
Step 4
Choose a CE Encapsulation type.
The choices are:
Note
Step 5
•
DOT1Q
•
DEFAULT
When creating a service request based on the Ethernet/EMS (EP-LAN) with CE policy, the
Encapsulation attribute is ignored. Therefore, setting this value has no effect.
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 12
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 13
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B EMS
(EP-LAN) Service.
Step 14
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID.
If you do not check this check box, you will be prompted to provide the VLAN in a Provider VLAN ID
field during service activation.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Step 16
Enter the System MTU in bytes.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-34
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
The maximum transmission unit (MTU) size is configurable and optional. The default size is 9216, and
the range is 1500 to 9216. ISC does not perform an integrity check for this customized value. If a service
request goes to the Failed Deploy state because this size is not accepted, you must adjust the size until
the Service Request is deployed.
In ISC 6.0, different platforms support different ranges.
Step 17
•
For the 3750 and 3550 platforms, the MTU range is 1500-1546.
•
For the 7600 ethernet port, the MTU size is always 9216. Even with the same platform and same
IOS release, different line cards support the MTU differently. For example, older line cards only take
an MTU size of 9216 and newer cards support 1500-9216. However, ISC 6.0 uses 9216 in both cases.
•
For the 7600 SVI (interface VLAN), the MTU size is 1500-9216.
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this is not checked and ISC automatically assigns a MAC-based ACL on the customer facing
UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the UNI Port Security check box (see Figure 9-30) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-35
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy with a CE
Figure 9-30
Step 21
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-31) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 9-31
Step 22
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 9-32) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 9-32
Protocol Tunnelling
For each protocol that you check, enter the shutdown threshold and drop threshold for that protocol:
a.
Tunnel CDP—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
CDP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-36
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Step 23
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Tunnel VTP—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
VTP threshold—Enter the number of packets per second to be received before the interface is shut
down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Tunnel STP—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
STP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
This section describes defining a VPLS policy with an Ethernet core type and an EMS (EP-LAN) service
type without a CE present. Figure 9-33 is an example of the first page of this policy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-37
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Figure 9-33
Ethernet/EMS (EP-LAN) Policy without a CE
Perform the following steps.
Step 1
Click Next.
The window in Figure 9-34 appears.
The Editable check box gives you the option of making a field editable. If you check the Editable check
box, the service operator who is using this VPLS policy can modify the editable parameter during VPLS
service request creation.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-38
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Figure 9-34
Step 2
Ethernet/EMS (EP-LAN) without CE Policy Attributes
Choose an Interface Type from the drop-down list.
You can choose a particular interface on a CE, N-PE, U-PE, or PE-AGG interface based on the service
provider’s POP design. The interfaces are:
•
ANY (Any interface can be chosen.)
•
Port-Channel (A bundle of ports that share the same characteristics—this gives the service provider
the ability to aggregate bandwidth and protection.)
•
Ethernet
•
FastEthernet
•
GE-WAN
•
GigabitEthernet
•
TenGigabitEthernet
•
TenGigE
The value defined here functions as a filter to restrict the interface types an operator can see during VPLS
service request creation. If defined as ANY, the operator can see all interface types.
Step 3
Check the Standard UNI Port check box to enable port security.
This is the default. When you uncheck the check box, the port is treated as an uplink with no security
features, and the window dynamically changes to eliminate items related to port security.
Step 4
Enter an Interface Format as the slot number/port number for the CE interface (for example, 1/0
indicates that the interface is located at slot 1, port 0).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-39
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
This is especially useful to specify here if you know that the link will always go through a particular
interface’s slot/port location on all or most of the network devices in the service.
Step 5
Choose a N-PE/U-PE Encapsulation type.
The choices are:
Note
•
DOT1Q
•
DEFAULT
When creating a service request based on the Ethernet/EMS (EP-LAN) without CE policy, the
Encapsulation attribute is ignored. Therefore, setting this value has no effect.
Step 6
Check the UNI Shutdown check box if you want to leave the UNI port shut during service activation,
for example, when the service provider wants to deploy a service in the network but wants to activate it
at a later time.
Step 7
Check the Keep Alive check box to configure keepalives on the UNI port.
By default, this check box is unchecked, which causes the command no keepalive to be provisioned on
the UNI port. This prevents a CPE from sending keepalive packets to the U-PE, for security purposes.
This attribute is editable to support modification on a per-service request basis.
Step 8
Check the ANY check box to display all interface types as choices for the UNI interface (when creating
service requests based on this policy).
This check box is checked by default.
Step 9
Check the UNI check box to display all interfaces defined as type UNI as choices for the UNI interface
(when creating service requests based on this policy).
This check box is checked by default.
Step 10
Enter one or more Ethernet MAC addresses in UNI MAC addresses.
This selection is present only if you uncheck the Use Existing ACL Name check box. Click the Edit
button to bring up a pop-up window in which you enter MAC addresses to be allowed or denied on the
port. You can also specify a range of addresses by setting a base MAC address and a filtered MAC
address.
Step 11
Enter a Link Speed (optional) of None, 10, 100, 1000, Auto, or nonegotiate.
Step 12
Enter a Link Duplex (optional) of None, Full, Half, or Auto.
Step 13
In the PE/UNI Interface Description field, enter an optional description, for example Customer-B EMS
(EP-LAN) Service.
Step 14
Check the VLAN ID AutoPick check box if you want ISC to choose a VLAN ID. If you do not check
this check box, you will be prompted to provide the VLAN in a Provider VLAN ID field during service
activation.
Step 15
Enter a VLAN NAME (optional) to specify a name to describe the VLAN.
The name must be one token (no spaces allowed.) The limit for the VLAN name is 32 characters. The
name has to be unique. Two VLANs cannot share the same name.
Step 16
Enter the System MTU in bytes.
The maximum transmission unit (MTU) size is configurable and optional. ISC does not perform an
integrity check for this customized value. If a service request goes to the Failed Deploy state because
this size is not accepted, you must adjust the size until the service request is deployed. ISC supports,
ranges for different platforms, as specified below. The range is 1500 to 9216.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-40
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Step 17
•
For the 3750 and 3550 platforms, the MTU range is 1500-1546.
•
For the 7600 ethernet port, the MTU size is always 9216. Even with the same platform and same
IOS release, different line cards support the MTU differently. For example, older line cards only take
an MTU size of 9216 and newer cards support 1500-9216. However, ISC uses 9216 in both cases.
•
For the 7600 SVI (interface VLAN), the MTU size is 1500-9216.
Check the Use Existing ACL Name check box if you want assign your own named access list to the port.
By default, this check box is not checked and ISC automatically assigns a MAC-based ACL on the
customer facing UNI port, based on values you enter in UNI MAC addresses (below).
Step 18
Enter a Port-Based ACL Name (if you checked the Use Existing ACL Name check box, as mentioned
in the previous step).
Note
ISC does not create this ACL automatically. The ACL must already exist on the device, or be
added as part of a template, before the service request is deployed. Otherwise, deployment will
fail.
Step 19
Check the Disable CDP check box if you want to disable the Cisco Discover Protocol (CDP) on the UNI
port.
Step 20
Check the UNI Port Security check box (see Figure 9-35) if you to want to provision port
security-related CLIs to the UNI port by controlling the MAC addresses that are allowed to go through
the interface.
a.
For Maximum Number of MAC address, enter the number of MAC addresses allowed for port
security.
b.
For Aging, enter the length of time the MAC address can stay on the port security table.
c.
For Violation Action, choose what action will occur when a port security violation is detected:
•
PROTECT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value.
•
RESTRICT—Drops packets with unknown source addresses until a sufficient number of secure
MAC addresses are removed to drop below the maximum value and causes the Security Violation
counter to increment.
•
SHUTDOWN—Puts the interface into the error-disabled state immediately and sends an SNMP
trap notification.
d.
In the Secure MAC Addresses field, enter one or more Ethernet MAC addresses.
Figure 9-35
Step 21
UNI Port Security
Check the Enable Storm Control check box (see Figure 9-36) to help prevent the UNI port from being
disrupted by a broadcast, multicast or unicast storm.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-41
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Enter a threshold value for each type of traffic. The value, which can be specified to two significant
digits, represents the percentage of the total available bandwidth of the port. If the threshold of a traffic
type is reached, further traffic of that type is suppressed until the incoming traffic falls below the
threshold level.
Figure 9-36
Step 22
Enable Storm Control
Check the Protocol Tunnelling check box (see Figure 9-37) if you want to define the Layer 2 Bridge
Protocol Data Unit (BPDU) frames that can be tunneled over the core to the other end.
Figure 9-37
Protocol Tunnelling
For each protocol that you check, enter the shutdown threshold and drop threshold for that protocol:
a.
Tunnel CDP—Enable Layer 2 tunnelling on Cisco Discover Protocol (CDP).
b.
CDP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
c.
cdp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping CDP packets.
d.
Tunnel VTP—Enable Layer 2 tunnelling on VLAN Trunk Protocol (VTP).
e.
VTP threshold—Enter the number of packets per second to be received before the interface is shut
down.
f.
vtp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping VTP packets.
g.
Tunnel STP—Enable Layer 2 tunnelling on Spanning Tree Protocol (STP).
h.
STP Threshold—Enter the number of packets per second to be received before the interface is shut
down.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-42
OL-21636-01
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Step 23
i.
stp drop threshold—Enter the number of packets per second to be received at which point the
interface will start dropping STP packets.
j.
Recovery Interval—Enter the amount of time, in seconds, to wait before recovering a UNI port.
Click the Next button, if you want to enable template support for the policy.
The Template Association window appears. In this window, you can enable template support and,
optionally, associate templates and data files with the policy. For instructions about associating
templates with policies and how to use the features in this window, see Appendix B, “Working with
Templates and Data Files”. When you have completed setting up templates and data files for the policy,
click Finish in the Template Association window to close it and return to the Policy Editor window.
Step 24
Note
Click Finish.
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this box, you can manually enter a VPN ID
in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
9-43
Chapter 9
Creating a VPLS Policy
Defining an Ethernet/EMS (EP-LAN) Policy without a CE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
9-44
OL-21636-01
CH A P T E R
10
Managing a VPLS Service Request
This chapter contains the basic steps to provision a VPLS service. It contains the following sections:
•
Introducing VPLS Service Requests, page 10-1
•
Creating a VPLS Service Request, page 10-2
•
Creating a VPLS Service Request with a CE, page 10-2
•
Creating a VPLS Service Request without a CE, page 10-6
•
Modifying the VPLS Service Request, page 10-10
•
Using the Bridge Domain ID Attribute, page 10-13
•
Saving the VPLS Service Request, page 10-14
Introducing VPLS Service Requests
A VPLS service request consists of one or more attachment circuits, connecting various sites in a
multipoint topology. When you create a service request, you enter several parameters, including the
specific interfaces on the CE and PE routers and UNI parameters. You can also integrate a Cisco IP
Solution Center (ISC) template with a service request. You can associate one or more templates to the
CE, PE, or any U-PE in the middle.
To create a service request, a service policy must already be defined, as described in Chapter 9, “Creating
a VPLS Policy.” Based on the predefined VPLS policy, an operator creates a VPLS service request, with
or without modifications to the VPLS policy, and deploys the service. The service request must be the
same service type (ERMS/EVP-LAN or EMS/EP-LAN) as the policy selected. Service creation and
deployment are normally performed by regular network technicians for daily operation of network
provisioning.
The following steps are involved in creating a service request for Layer 2 connectivity between customer
sites:
•
Choose a VPLS policy.
•
Choose a VPN. For more information, see Defining VPNs, page 2-4.
•
Add a link.
•
Choose a CE or UNI interface.
•
Choose a Named Physical Circuit (NPC) if more than one NPC exists from the CE or the UNI
interface.
•
Edit the link attributes.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-1
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request
Creating a VPLS Service Request
To create a VPLS service request, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears.
Step 2
Click Create.
Step 3
Choose VPLS from the drop-down list.
VPLS service requests must be associated with a VPLS policy. You choose a VPLS policy from the
policies previously created (see Chapter 9, “Creating a VPLS Policy”).
Step 4
If more than one VPLS policy exists, a list of VPLS policies appears. Choose the button for the VPLS
policy of choice.
Step 5
After you make the choice, click OK.
The new service request inherits all the properties of that VPLS policy, such as all the editable and
noneditable features and preset parameters.
Creating a VPLS Service Request with a CE
This section includes detailed steps for creating a VPLS service request with a CE present. In this
example, the service request is for an VPLS policy over an MPLS core with an ERMS (EVP-LAN)
service type and CE present.
Perform the following steps.
Step 1
Choose the appropriate VPLS policy.
The VPLS Service Request Editor window appears. (See Figure 10-1.)
Figure 10-1
VPLS Service Request Editor
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-2
OL-21636-01
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request with a CE
Step 2
Click Select VPN to choose a VPN for use with this CE.
The Select VPN window appears with the VPNs defined in the system. Only VPNs with the same service
type (ERMS/EVP-LAN or EMS/EP-LAN) as the policy you chose appear. (See Figure 10-2.)
Figure 10-2
Note
Select a VPN
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this check box, you can manually enter a VPN
ID in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Step 3
Choose a VPN Name in the Select column.
Step 4
Click Select. The VPLS Link Editor window appears with the VPN name displayed.
Step 5
Click Add Link.
You specify the CE endpoints using the VPLS Link Editor. You can add one or more links from a window
like the one in Figure 10-3.
Figure 10-3
Select CE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-3
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request with a CE
Step 6
You can enter a description for the service request in the first Description field.
The description will show up in this window and also in the Description column of the Service Requests
window. The maximum length for this field is 256 characters.
Step 7
Click Select CE in the CE column.
The Select CPE Device window appears. (See Figure 10-4.)
Figure 10-4
Select CPE Device
This window displays the list of currently defined CEs.
a.
From the Show CPEs with drop-down list, you can display CEs by Customer Name, by Site, or by
Device Name.
b.
You can use the Find button to either search for a specific CE, or to refresh the display.
c.
You can set the Rows per page to 5, 10, 20, 30, 40, or All.
Step 8
In the Select column, choose a CE for the VPLS link.
Step 9
Click Select.
The VPLS Link Editor window appears displaying the name of the selected CE in the CE column.
Step 10
Choose the CE interface from the drop-down list. (See Figure 10-5.)
Figure 10-5
Select the CE Interface
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-4
OL-21636-01
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request with a CE
Note
Step 11
When you provision an ERMS (EVP-LAN) service (and when you choose a UNI for a particular device),
ISC determines if there are other services using the same UNI. If so, a warning message is displayed. If
you ignore the message and save the service request, all of the underlying service requests lying on the
same UNI are synchronized with the modified shared attributes of the latest service request. In addition,
the state of the existing service requests is changed to the Requested state.
Click Select one circuit in the Circuit Selection column.
The Select NPC window appears. If only one NPC exists for the chosen CE and CE interface, that NPC
is automatically populated in the Circuit Selection column and you need not choose it explicitly.
Step 12
Choose the name of the NPC from the Select column.
Step 13
Click OK.
Each time you choose a CE and its interface, the NPC that was precreated from this CE and interface is
automatically displayed under Circuit Selection. (See Figure 10-6.) This means that you do not have to
further specify the PE to complete the link.
Figure 10-6
Step 14
NPC Selected
If you want to review the details of this NPC, click Circuit Details in the Circuit Details column.
The NPC Details window appears and lists the circuit details for this NPC.
Step 15
The Circuit ID is created automatically, based on the VLAN data for the circuit.
Step 16
To edit values that were set by the VPLS policy, that is, the values that were marked “editable” during
the VPLS policy creation, click the Edit link in the Link Attributes column for a link.
The Link Attributes window appears.
Note
For more information on setting attributes in this window, see Modifying the VPLS Service Request,
page 10-10.
Note
For information on the Bridge Domain ID attribute, which shows up in some VPLS service request
scenarios, see Modifying the VPLS Service Request, page 10-10.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-5
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request without a CE
Step 17
Continue to specify additional CEs, as in previous steps, if desired.
Step 18
Click OK.
Step 19
Click Save.
The service request is created and saved into ISC.
Creating a VPLS Service Request without a CE
This section includes detailed steps for creating a VPLS service request without a CE present. In this
example, the service request is for an VPLS policy over an MPLS core with an EMS (EP-LAN) service
type and no CE present.
Perform the following steps.
Step 1
Choose the appropriate VPLS policy.
The VPLS Service Request Editor window appears. (See Figure 10-7.)
Figure 10-7
Step 2
VPLS Service Request Editor
Click Select VPN to choose a VPN for use with this PE.
The Select VPN window appears with the VPNs defined in the system. Only VPNs with the same service
type (ERMS/EVP-LAN or EMS/EP-LAN) as the policy you chose appear. (See Figure 10-8.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-6
OL-21636-01
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request without a CE
Figure 10-8
Note
Select a VPN
The VC ID is mapped from the VPN ID. By default, ISC will “auto pick” this value. However, you can
set this manually, if desired. This is done by editing the associated VPN configuration. The Edit VPN
window has an Enable VPLS check box. When you check this check box, you can manually enter a VPN
ID in a field provided. For more information on creating and modifying VPNs, see the Cisco IP Solution
Center Infrastructure Reference, 6.0.
Step 3
Choose a VPN Name in the Select column.
Step 4
Click Select.
The VPLS Link Editor window appears with the VPN name displayed.
Step 5
Click Add Link.
You specify the U-PE/PE-AGG/U-PE endpoints using the VPLS Link Editor. You can add one or more
links from a window like the one in Figure 10-9.
Figure 10-9
Step 6
Select N-PE/PE-AGG/U-PE
You can enter a description for the service request in the first Description field.
The description will show up in this window and also in the Description column of the Service Requests
window. The maximum length for this field is 256 characters.
Step 7
Click Select N-PE/PE-AGG/U-PE in the N-PE/PE-AGG/U-PE column.
The Select PE Device window appears. (See Figure 10-10.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-7
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request without a CE
Figure 10-10
Select PE Device
This window displays the list of currently defined PEs.
a.
The Show PEs with drop-down list shows PEs by customer name, by site, or by device name.
b.
The Find button allows a search for a specific PE or a refresh of the window.
c.
The Rows per page drop-down list allows the page to be set to 5, 10, 20, 30, 40, or All.
Step 8
In the Select column, choose the PE device name for the VPLS link.
Step 9
Click Select.
The VPLS Link Editor window appears displaying the name of the selected N-PE/PE-AGG/U-PE in the
N-PE/PE-AGG/U-PE column
Step 10
Choose the UNI interface from the drop-down list. (See Figure 10-11.)
Figure 10-11
Select the UNI Interface
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-8
OL-21636-01
Chapter 10
Managing a VPLS Service Request
Creating a VPLS Service Request without a CE
Note
Step 11
When you provision an ERMS (EVP-LAN) service (and when you choose a UNI for a particular device),
ISC determines if there are other services using the same UNI. If so, a warning message is displayed. If
you ignore the message and save the service request, all of the underlying service requests lying on the
same UNI are synchronized with the modified shared attributes of the latest service request. In addition,
the state of the existing service requests is changed to the Requested state.
If the PE role type is U-PE, click Select one circuit in the Circuit Selection column.
The Select NPC window appears. If only one NPC exists for the chosen PE and PE interface, that NPC
is automatically populated in the Circuit Selection column and you need not choose it explicitly.
Note
If the PE role type is N-PE, the columns Circuit Selection and Circuit Details are disabled.
Step 12
Choose the name of the NPC from the Select column.
Step 13
Click OK.
Each time you choose a PE and its interface, the NPC that was precreated from this PE and interface is
automatically displayed under Circuit Selection. (See Figure 10-12.) This means that you do not have
to further specify the PE to complete the link.
Figure 10-12
Step 14
NPC Created
If you want to review the details of this NPC, click Circuit Details in the Circuit Details column.
The NPC Details window appears and lists the circuit details for this NPC.
The Circuit ID is created automatically, based on the VLAN data for the circuit.
Step 15
To edit values that were set by the VPLS policy, that is, the values that were marked “editable” during
the VPLS policy creation, click the Edit link in the Link Attributes column for a link.
Note
For more information on setting attributes in this window, see Modifying the VPLS Service Request,
page 10-10.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-9
Chapter 10
Managing a VPLS Service Request
Modifying the VPLS Service Request
Note
For information on the Bridge Domain ID attribute, which shows up in some VPLS service request
scenarios, see Modifying the VPLS Service Request, page 10-10.
Step 16
Continue to specify additional PEs, as in previous steps, if desired.
Step 17
Click Save.
The VPLS service request is created and saved into ISC.
Modifying the VPLS Service Request
You can modify a VPLS service request if you must change or modify the VPLS links. This is also where
you can associate templates and data files to a link.
Perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests. (See
Figure 10-13.)
Figure 10-13
VPLS Service Activation
Step 2
Check a check box for a service request.
Step 3
Click Edit.
The VPLS Link Editor window appears. (See Figure 10-14.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-10
OL-21636-01
Chapter 10
Managing a VPLS Service Request
Modifying the VPLS Service Request
Figure 10-14
Step 4
Specify remaining items in the End-to-End-Wire Editor window, as necessary for your configuration:
•
Choose any of the blue highlighted values to edit the VPLS links.
•
Click Add Link to add a VPLS link.
•
Click Delete Link to delete a VPLS link.
Note
Step 5
VPLS Link Editor
If you are attempting to decommission a service request to which a template has been added, see
Monitoring Service Requests, page 11-10 for information on the proper way to do this.
•
You can enter a description for the service request in the first Description field. The description will
show up in this window and also in the Description column of the Service Requests window. The
maximum length for this field is 256 characters.
•
The Circuit ID is created automatically, based on the VLAN data for the circuit.
To modify the link attributes, click Edit in the Link Attributes column as shown in the VPLS link editor.
The Link Attributes window appears.
Step 6
Step 7
Edit the link attributes as desired.
Note
If you did not choose VLANI D AutoPick in the VPLS policy, you are prompted to provide the
VLAN in a Provider VLAN ID field.
Note
For information on the Bridge Domain ID attribute, which shows up in some VPLS service
request scenarios, see Modifying the VPLS Service Request, page 10-10.
To add a template and data file to a link, choose a Device Name, and click Add under Templates.
The Add/Remove Templates window appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-11
Chapter 10
Managing a VPLS Service Request
Modifying the VPLS Service Request
Note
Step 8
To add a template to a link, you must have already created the template. For detailed steps to
create templates, see the Cisco IP Solution Center Infrastructure Reference, 6.0. For more
information on how to use templates and data files in service requests, see Appendix B,
“Working with Templates and Data Files.”
Click Add.
The Template Data File Chooser window appears.
Step 9
In the left pane, navigate to and select a template.
The associated data files are listed in rows in the main window.
Step 10
Check the data file that you want to add and click Accept.
The Add/Remove Templates window appears with the template displayed.
Step 11
Choose a Template name.
Step 12
Under Action, use the drop-down list and choose APPEND or PREPEND.
Append tells ISC to append the template generated CLI to the regular ISC (non-template) CLI. Prepend
is the reverse and does not append the template to the ISC CLI.
Step 13
Choose Active to use this template for this service request.
If you do not choose Active, the template is not used.
Step 14
Click OK.
The Link Attributes with the template added appears.
Step 15
Click OK.
The Service Request Editor window appears.
Step 16
When you are finished editing the VPLS links, click Save.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-12
OL-21636-01
Chapter 10
Managing a VPLS Service Request
Using the Bridge Domain ID Attribute
Using the Bridge Domain ID Attribute
The Bridge Domain ID attribute appears in the Link Attributes window of some VPLS service request
scenarios, as shown in Figure 10-15.
Figure 10-15
Bridge Domain ID Attribute
To use the Bridge Domain ID attribute, enter an ID number in the Bridge Domain ID text field to enable
bridge domain functionality for the VPLS service request.
Acceptable values are 1 to 4294967295.
Usage notes:
•
The Bridge Domain ID attribute is only available for the following service request scenarios:
– Ethernet/ERMS (EVP-LAN) with a CE
– Ethernet/ERMS (EVP-LAN) without a CE
– Ethernet/EMS (EP-LAN) with a CE
– Ethernet/EMS (EP-LAN) without a CE
•
The Bridge Domain ID attribute is only supported for the Cisco GSR 12406 running
IOS 12.0(32)SY6 and functioning in an N-PE role. This attribute will show up in a service request
only for this platform; otherwise, the attribute will be filtered from the Link Attributes window of
the service request.
•
The following points apply to service requests based on this policy:
– When an N-PE (GSR platform) is used as a UNI device, the standard UNI attributes are not
displayed in the Link Attributes window of the service request workflow.
– When a U-PE (non-GSR platform) is used as a UNI device, all standard UNI attributes are
displayed in the Link Attributes window of the service request workflow.
– For VPLS EMS services, a U-PE (non-GSR platform) should be used in the same circuit which
is terminating on a GSR device (N-PE). In other words, an NPC circuit should be used to
provision VPLS EMS on GSR devices.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
10-13
Chapter 10
Managing a VPLS Service Request
Saving the VPLS Service Request
Saving the VPLS Service Request
To save a VPLS service request, perform the following steps.
Step 1
When you are finished with Link Attributes for all the Attachment Circuits, click Save to finish the
VPLS service request creation.
If the VPLS service request is successfully created, you will see the service request list window. (See
Figure 10-16.) The newly created VPLS service request is added with the state of REQUESTED, as
shown in the figure.
Figure 10-16
Step 2
VPLS Service Request Created
If, however, the VPLS service request creation failed for some reason (for example, a value chosen is
out of bounds), you are warned with an error message.
In such a case, you should correct the error and save the service request again.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
10-14
OL-21636-01
CH A P T E R
11
Deploying, Monitoring, and Auditing Service
Requests
This chapter describes how to deploy, monitor and audit L2VPN, VPLS or FlexUNI/EVC service
requests, and how to access task logs. It contains the following sections:
•
Deploying Service Requests, page 11-1
•
Monitoring Service Requests, page 11-10
•
Auditing Service Requests, page 11-12
Deploying Service Requests
To apply L2VPN, VPLS, or FlexUNI policies to network devices, you must deploy the service request.
When you deploy a service request, ISC compares the device information in the Repository (the ISC
database) with the current device configuration and generates a configlet.
Pre-Deployment Changes
You can change the Dynamic Component Properties Library (DCPL) parameter
actionTakenOnUNIVlanList before you deploy an L2VPN or VPLS service request. This will be
necessary if the trunk allowed vlan list is not present on the User Network Interface (UNI).
To make this change, perform the following steps.
Step 1
Choose Administration > Control Center.
Step 2
Choose the host that you want to change.
Step 3
Click Config.
Step 4
Choose Provisioning > Service > shared > actionTakenOnUNIVlanList.
The window shown in Figure 11-1 appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-1
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
Figure 11-1
Step 5
Step 6
Change DCPL Parameter
Choose one of the following:
•
prune to have ISC create the minimum VLAN list. This is the default.
•
abort to have ISC stop the L2VPN or VPLS service request provisioning with the error message:
trunk allowed vlan list is absent on ERS UNI.
•
nochange to have ISC allow all VLANs.
Click Set Property.
Service Deployment
After you create a service request and save it in the ISC repository, you can deploy or force-deploy it.
Perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears.
Step 2
Choose a service request.
Step 3
Click Deploy and choose Deploy or Force-Deploy.
Use Deploy when the service request state is Requested or Invalid.
Use Force Deploy when the service request state is Deployed, Failed Deployed, or Failed Audit.
The Deploy Service Requests window appears. (See Figure 11-2.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-2
OL-21636-01
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
Figure 11-2
Schedule Service Activation
Step 4
Choose a schedule for the activation of the service.
Step 5
After you schedule the service request, click Save.
After you schedule the service request, you can monitor the service request that is being deployed. See
Verifying Service Requests, page 11-3 and Monitoring Service Requests, page 11-10 for more
information.
Verifying Service Requests
After you deploy a service request, you should verify that there were no errors.
You can verify a service request through the following:
•
Transition state—The transition state of a service request is listed on the Service Requests window
in the State column. When the service request is successfully deployed, its state changes to
DEPLOYED. For more information, see Service Request States, page 11-4.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-3
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
•
View service request details—From the Service Requests Details window, you can view the link
endpoints and the configlets for this service request. For more information, See Viewing Service
Request Details, page 11-7.
•
Task Logs—Access the task logs from the Monitoring tab to help you troubleshoot a failed service
request or to view more details about a service request. For more information, see Monitoring
Service Requests, page 11-10.
Service Request States
A service request transition state describes the different stages a service request enters during the
provisioning process. For example, when you deploy a service request, ISC compares the device
information in the Repository (the ISC database) with the current device configuration and generates a
configlet. When the configlet is generated and downloaded to the device, the service request enters the
Pending state. When the device is audited, the service request enters the Deployed state.
Figure 11-3, “Service Requests States Transition Diagram,” shows a high-level diagram of the
relationships and movement among ISC service request states.
Figure 11-3
Service Requests States Transition Diagram
Table 11-1, “Summary of Cisco IP Solution Center Service Request States,” describes the functions of
each ISC service request state. They are listed in alphabetic order.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-4
OL-21636-01
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
Table 11-1
Summary of Cisco IP Solution Center Service Request States
Service Request Type
Description
Broken
The router is correctly configured but the service is unavailable (due to a
broken cable or Layer 2 problem, for example).
(valid only for MPLS
services)
An MPLS service request moves to Broken if the auditor finds the routing
and forwarding tables for this service, but they do not match the service
intent.
Closed
A service request moves to Closed if the service request should no longer be
used during the provisioning or auditing process. A service request moves to
the Closed state only upon successful audit of a decommission service
request. ISC does not remove a service request from the database to allow
for extended auditing. Only a specific administrator purge action results in
service requests being removed.
Deployed
A service request moves to Deployed if the intention of the service request
is found in the router configuration file. Deployed indicates that the
configuration file has been downloaded to the router, and the intent of the
request has been verified at the configuration level. That is, ISC downloaded
the configlets to the routers and the service request passed the audit process.
Failed Audit
This state indicates that ISC downloaded the configlet to the router
successfully, but the service request did not pass the audit. Therefore, the
service did not move to the Deployed state. The Failed Audit state is
initiated from the Pending state. After a service request is deployed
successfully, it cannot re-enter the Failed Audit state (except if the service
request is redeployed).
Failed Deploy
The cause for a Failed Deploy status is that DCS reports that either the
upload of the initial configuration file from the routers failed or the
download of the configuration update to the routers failed (due to lost
connection, faulty password, and so on).
Functional
An MPLS service request moves to Functional when the auditor finds the
VPN routing and forwarding tables (VRF) for this service and they match
with the service intent. This state requires that both the configuration file
audit and the routing audit are successful.
(valid only for MPLS
services)
Invalid
Invalid indicates that the service request information is incorrect in some
way. A service request moves to Invalid if the request was either internally
inconsistent or not consistent with the rest of the existing network/router
configurations (for example, no more interfaces were available on the
router). The Provisioning Driver cannot generate configuration updates to
service this request.
Lost
A service request moves to Lost when the Auditor cannot find a
configuration-level verification of intent in the router configuration files.
The service request was in the Deployed state, but now some or all router
configuration information is missing. A service request can move to the Lost
state only when the service request had been Deployed.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-5
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
Table 11-1
Summary of Cisco IP Solution Center Service Request States (continued)
Service Request Type
Description
Pending
A service request moves to Pending when the Provisioning Driver
determines that the request looks consistent and was able to generate the
required configuration updates for this request. Pending indicates that the
service request has generated the configuration updates and the
configuration updates are successfully downloaded to the routers.
The Auditor regards pending service requests as new requests and begins the
audit. If the service has been freshly provisioned and not yet audited, it is not
an error (pending audit). However, if an audit is performed and the service is
still pending, it is in an error state.
Requested
If the service is newly entered and not yet deployed, it is not an error.
However, if a Deploy is done and it remains Requested, the service is in an
error state.
Wait Deploy
This service request state pertains only when downloading configlets to a
server running Cisco Configuration Engine. Wait Deploy indicates that the
configlet has been generated, but it has not been downloaded to the Cisco
Configuration Engine server because the device is not currently online. The
configlet is staged in the repository until such time as the Cisco
Configuration Engine server notifies ISC that it is up. Configlets in the
Wait Deploy state are then downloaded to the Cisco Configuration Engine
server.
Table 11-2, “User Operations on ISC Service Requests,” describes user operations and their impact on
ISC service requests.
Table 11-2
User Operations on ISC Service Requests
User Operations
Description
Decommission
This user operation removes the service from all devices in the service
request.
Force Deploy
This user operation allows you to Deploy a service request from any state
except Closed. This is equivalent to restarting the state diagram. The service
request can move from its current state to any other possible state. However,
it does not move to the Requested state.
Force Purge
This user operation removes a service request from the database irrespective
of its state. If you Force Purge a service request from the ISC repository
before first decommissioning the service request, the service remains
running on the network (specifically, the configuration remains on the
devices on which the service was provisioned), but all record of the service
request that created the service is removed from ISC.
Purged
When a service request is Purged, it is removed from the ISC database.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-6
OL-21636-01
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
Viewing Service Request Details
The service request details include the link endpoints for the service request, the history, and the
configlet generated during the service request deployment operation. Use the service request details to
help you troubleshoot a problem or error with the service request or to check the commands in the
configlet.
From the Service Request Details page, you can view more information about:
•
Links—the link endpoint details
•
History—Service request history report
•
Audit—Audit reports for the link IDs
•
Configlets—View the ISC generated configlet for the L2VPN or VPLS service request
The following sections describe the links, history, and configlet details for an L2VPN or VPLS service
request. The audit details are described in Auditing Service Requests, page 11-12.
To view service request details, perform the following steps.
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears.
Step 2
Choose the service request and click Details.
The Service Request Details window appears. (See Figure 11-4.)
Figure 11-4
Example Service Request Details Window
The service request attribute details include the type, transition state, operation type, ID, modification
history, customer, and policy name.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-7
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
Links
The service request link details include the link endpoints, PE secured interface, VLAN ID, and whether
a CE is present.
To see this information, perform the following steps.
Step 1
Click Links on the Service Request Details window. (See Figure 11-4.)
The Service Request Links window appears. (See Figure 11-5.)
Figure 11-5
Step 2
Service Request Links
Choose a link and click Details.
The Link Details window appears. (See Figure 11-6.)
Figure 11-6
Link Details Window
Step 3
Click OK to return to the Service Request Links window.
Step 4
Choose another link to view or click OK to return to the Service Request Details window.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-8
OL-21636-01
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Deploying Service Requests
History
To view history information about the service request, perform the following steps.
Step 1
Click History on the Service Request Details window. (See Figure 11-4.)
The Service Request State Change Report window appears. (See Figure 11-7.)
Figure 11-7
Service Request State Change Report
The history reports lists the following information about the service request:
Step 2
•
Element Name—the device, interface, and subinterfaces participating in this service request
•
State—the transition states the element has gone through
•
Create Time—the time the element was created for this service request
•
Report—the action taken by ISC for the element in this service request
Click OK to return to the Service Request Details window.
Configlets
After you deploy the service request, ISC generates Cisco IOS commands to turn on L2VPN or VPLS
Services on all the network devices that participate in the service request.
To view the configlets that are generated, perform the following steps.
Step 1
Click Configlets on the Service Request Details window. (See Figure 11-4.)
You see a list of network devices for which a configlet was generated. (See Figure 11-8.)
Figure 11-8
Step 2
Service Request Configlets
Choose the device for which you want to view the configlet.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-9
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Monitoring Service Requests
Step 3
Click View Configlet.
The Configlet for Device window appears. (See Figure 11-9.)
Figure 11-9
L2VPN or VPLS Configlet Example
The device configlet shows all commands downloaded to the device configuration during the service
request deployment operation.
Step 4
Click OK to exit.
Monitoring Service Requests
To monitor a service request that is being deployed, you must use the task logs to help you troubleshoot
why a service request has failed or to find more details about a service request.
To monitor a service request, perform the following steps.
Step 1
Choose Monitoring > Task Manager.
The Tasks window appears. (See Figure 11-10.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-10
OL-21636-01
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Monitoring Service Requests
Figure 11-10
Step 2
Tasks Window
Click Find to refresh the window.
The task that is executing will be the first in the list of tasks that being performed in ISC.
Step 3
Choose the task you want to monitor and click Logs.
The Task Logs window appears. (See Figure 11-11.)
Figure 11-11
Step 4
Task Logs
Choose the run-time task that you want to monitor and click View Log.
A window like the one shown in Figure 11-12 appears.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-11
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Auditing Service Requests
Figure 11-12
Step 5
Task Logs
Choose the log level from the drop-down list and click Filter.
The log levels are All, Severe, Warning, Info, Config, Fine, Finer, and Finest.
Step 6
Click Return to Logs.
Step 7
Click Close in the Task Logs window.
Auditing Service Requests
Each time a service request is deployed in the Cisco IP Solution Center (ISC), a configuration audit
occurs. You can view the results of these in configuration audit reports. Use configuration audits and
reports to verify that the network devices have the correct configuration for the services provided.
A configuration audit occurs automatically each time you deploy a service request. During this
configuration audit, ISC verifies that all Cisco IOS commands are present and that they have the correct
syntax. An audit also verifies that there were no errors during deployment.
The configuration audit verifies the service request deployment by examining the commands configured
by the service request on the target devices. If the device configuration does not match what is defined
in the service request, the audit flags a warning and sets the service request to a Failed Audit or Lost
state.
You can create audit reports for new or existing service requests.
•
Audit new services—This type of audit is for service requests that have just been deployed. The
audit identifies problems with the configuration files downloaded to the devices.
•
Audit existing services—This type of audit checks and evaluates the configuration of deployed
service requests to see if the service request is still in effect.
We recommend that you schedule a service request audit on a regular basis to verify the state of the
network provisioning requests.
This section describes how to manually generate a configuration audit and view the audit report.
To view a configuration audit report, perform the following steps.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-12
OL-21636-01
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Auditing Service Requests
Step 1
Choose Service Inventory > Inventory and Connection Manager > Service Requests.
The Service Requests window appears.
Step 2
Choose an service request for the configuration audit.
Step 3
Click Details.
The Service Request Details window appears.
Step 4
Click Audit.
Step 5
Click Config.
The Service Request Audit window appears. Figure 11-13 shows an example of a successful
configuration audit.
Figure 11-13
Service Request Audit Report—Successful
This window lists the device name and role, and a message regarding the status of your configuration
audit.
If the audit is unsuccessful, the message field lists details on the failed audit. Figure 11-14 shows an
example of a failed audit message for an service request.
Figure 11-14
Service Request Audit Report—Failed
The audit failure message indicates missing commands and configuration issues. Carefully review the
information in the message field. If the audit fails, you must correct all errors and redeploy the service
request.
Step 6
Click OK to return to the Service Request Details window.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
11-13
Chapter 11
Deploying, Monitoring, and Auditing Service Requests
Auditing Service Requests
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
11-14
OL-21636-01
CH A P T E R
12
Using Autodiscovery for L2 Services
All discovery steps are integrated in a discovery workflow, controlled from the ISC GUI. This is
accessed in ISC through Service Inventory > Discovery. The following discovery features are
supported:
•
File-based device discovery is supported.
•
Rules-based device role assignment is supported.
•
Discovery progress messages and logs are viewable in the GUI to keep track of various discovery
stages.
•
Bulk creation of Provider, Customer, Site, and Region objects is available through an XML data file.
For detailed steps on using the autodiscovery feature in ISC, see the Cisco IP Solution Center
Infrastructure Reference, 6.0.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
12-1
Chapter 12
Using Autodiscovery for L2 Services
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
12-2
OL-21636-01
CH A P T E R
13
Generating L2 and VPLS Reports
This chapter provides information on generating L2 and VPLS reports. It contains the following
sections:
•
Overview, page 13-1
•
Accessing L2 and VPLS Reports, page 13-1
•
L2 and VPLS Reports, page 13-2
•
Creating Custom L2 and VPLS Reports, page 13-11
Overview
The ISC reporting GUI is used across multiple ISC modules, including L2 and VPLS. For a general
coverage of using the reports GUI, running reports, using the output from reports, and creating
customized reports, see “Monitoring” chapter in the Cisco IP Solution Center Infrastructure Reference,
6.0. The rest of this chapter provides information about the L2 and VPLS reports available in ISC.
Accessing L2 and VPLS Reports
Perform the following steps to access the L2 and VPLS reports.
Step 1
To access the reports framework in the ISC GUI, choose Monitoring > Reports.
The Reports window appears. (See Figure 13-1.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
13-1
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
Figure 13-1
Reports Window
Step 2
Click the L2 folder to display the available L2 and VPLS reports.
Step 3
Click the icon of a report to bring up the window associated with that report.
Details on each of the reports are provided in L2 and VPLS Reports, page 13-2.
L2 and VPLS Reports
This section provides details on the following L2 and VPLS reports:
Note
•
L2 End-to-End Wire Report, page 13-3
•
L2 PE Service Report, page 13-6
•
L2 VPN Report, page 13-7
•
VPLS Attachment Circuit Report, page 13-8
•
VPLS PE Service Report, page 13-10
•
VPLS VPN Report, page 13-11
Several sample reports are provided in the L2 reports folder. These reports begin with the title
SAMPLE-. These reports are provided for informational purposes only. They are untested and
unsupported. You might want to use them as a basis for creating your own custom reports. For more
information, see Creating Custom L2 and VPLS Reports, page 13-11.
The following information is provided for each report:
•
Description or purpose of the report.
•
An illustration of the report window.
•
List of filter values and descriptions.
•
List of output values and descriptions.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
13-2
OL-21636-01
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
L2 End-to-End Wire Report
An L2 end-to-end wire is a point-to-point connection containing two attachment circuits. The L2
EndtoEndWire report displays the services that are running on L2 end-to-end connections. You can use
this report to view all the services and respective attachment circuit attributes for each connection.
Click the L2 EndtoEndWire Report icon to bring up the window for this report. (See Figure 13-2.)
Figure 13-2
L2 EndtoEndWire Report
Filter Values:
•
EndToEndWire ID—End-to-end wire identification number.
•
Customer Name—Name of the customer.
•
VC ID—Virtual circuit identification number.
•
SR Job ID—Service request job identification number.
•
Service Type—Type of service. Values can be:
– ATM
– ATM_NO_CE
– FRAME_RELAY
– FRAME_RELAY_NO_CE
– L2VPN_ERS
– L2VPN_ERS_NO_CE
– L2VPN_EWS
– L2VPN_EWS_NO_CE
•
SR State—Service request state. Values can be:
– BROKEN
– DEPLOYED
– FAILED_AUDIT
– FAILED_DEPLOY
– FUNCTIONAL
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
13-3
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
– INVALID
– LOST
– PENDING
– REQUESTED
– WAIT_DEPLOY
•
AC1-ID—First attachment circuit (AC1) identification number.
•
AC2-ID—Second attachment circuit (AC2) identification number.
Output Values:
•
EndToEndWire ID—End-to-end wire identification number.
•
Customer Name—Name of the customer.
•
VPN—Name of the VPN.
•
VC ID—Virtual circuit identification number.
•
SR ID—Service request identification number.
•
SR Job ID—Service request job identification number.
•
Service Type—Type of service.
•
SR State—Service request state.
Note
The SR State output does not list service requests in the CLOSED state. Service requests in
other states are listed, as determined by the filter values.
•
AC1-ID—Identification number of the first attachment circuit (AC1).
•
AC1-UNI Device Interface—UNI device interface of the first attachment circuit (AC1).
•
AC1-NPC—Named physical circuit for the first attachment circuit (AC1).
•
AC2-VLAN ID/DLCI/VCD—VLAN identification number, DLCI (data-link connection identifier)
or VCD (virtual circuit descriptor) of the first attachment circuit (AC1).
•
AC1-VPI—Virtual path identifier for the first attachment circuit (AC1).
•
AC1-VCI—Virtual channel identifier for the first attachment circuit (AC1).
•
AC1-Interface Encap Type—Encapsulation type used for the first attachment circuit (AC1).
•
AC1-AccessDomain—Access domain name for the first attachment circuit (AC1).
•
AC1-Customer Facing UNI—Customer-facing UNI port of the first attachment circuit (AC1).
•
AC1-Loopback IP Address—Loop back address for the first attachment circuit (AC1).
•
AC1-STP Shutdown Threshold—Spanning Tree Protocol shutdown threshold (in packets/second)
for the first attachment circuit (AC1).
•
AC1-VTP Shutdown Threshold—VLAN Trunk Protocol shutdown threshold (in packets/second)
for the first attachment circuit (AC1).
•
AC1-CDP Shutdown Threshold—Cisco Discovery Protocol shutdown threshold (in
packets/second) for the first attachment circuit (AC1).
•
AC1-STP Drop Threshold—Spanning Tree Protocol drop threshold (in packets/second) for the
first attachment circuit (AC1).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
13-4
OL-21636-01
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
•
AC1-CDP Drop Threshold—Cisco Discovery Protocol drop threshold (in packets/second) for the
first attachment circuit (AC1).
•
AC1-VTP Drop Threshold—VLAN Trunk Protocol drop threshold (in packets/second) for the first
attachment circuit (AC1).
•
AC1-UNI Recovery Interval—Recovery interval (in seconds) of the UNI port for the first
attachment circuit (AC1).
•
AC1-UNI Speed—UNI port speed for the first attachment circuit (AC1).
•
AC1-UNI Shutdown—Shutdown status of the UNI port for the first attachment circuit (AC1).
•
AC1-UNI PortSecurity—Status of UNI port security for the first attachment circuit (AC1).
•
AC1-UNI Duplex—Duplex status (none, full, half, or auto) of the UNI port for the first attachment
circuit (AC1).
•
AC1-Maximum MAC Address—Maximum MAC addresses allowed on the UNI port for the first
attachment circuit (AC1).
•
AC1-UNI Aging—Length of time, in seconds, that MAC addresses can stay in the UNI port security
table for the first attachment circuit (AC1).
•
AC2-ID—Second attachment circuit (AC2) identification number.
•
AC2-UNI Device Interface—UNI device interface of the second attachment circuit (AC2).
•
AC2-NPC—Named physical circuit for the second attachment circuit (AC2).
•
AC2-VLAN ID/DLCI/VCD—The VLAN ID, DLCI or VCD of the second attachment circuit
(AC2).
•
AC2-VPI—Virtual path identifier for the first attachment circuit (AC2).
•
AC2-VCI—Virtual channel identifier for the first attachment circuit (AC2).
•
AC2-Interface Encap Type—Encapsulation type used for the second attachment circuit (AC2).
•
AC2-AccessDomain—Access domain name for the second attachment circuit (AC2).
•
AC2-Customer Facing UNI—Customer-facing UNI port of the second attachment circuit (AC2).
•
AC2-Loopback IP Address—Loop back address for the second attachment circuit (AC2).
•
AC2-STP Shutdown Threshold—Spanning Tree Protocol shutdown threshold for the second
attachment circuit (AC2).
•
AC2-VTP Shutdown Threshold—VLAN Trunk Protocol shutdown threshold for the second
attachment circuit (AC2).
•
AC2-CDP Shutdown Threshold—Cisco Discovery Protocol shutdown threshold for the second
attachment circuit (AC2).
•
AC2-STP Drop Threshold—Spanning Tree Protocol drop threshold for the second attachment
circuit (AC2).
•
AC2-CDP Drop Threshold—Cisco Discovery Protocol drop threshold for the second attachment
circuit.
•
AC2-VTP Drop Threshold—VLAN Trunk Protocol drop threshold for the second attachment
circuit (AC2).
•
AC2-UNI Recovery Interval—Recovery interval of the UNI port for the second attachment circuit
(AC2).
•
AC2-UNI Speed—UNI port speed for the second attachment circuit (AC2).
•
AC2-UNI Shutdown—Shutdown status of the UNI port for the second attachment circuit (AC2).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
13-5
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
•
AC2-UNI PortSecurity—Status of UNI port security for the second attachment circuit (AC2).
•
AC2-UNI Duplex—Duplex status (none, full, half, or auto) of the UNI port for the second
attachment circuit (AC2).
•
AC2-Maximum MAC Address—Maximum MAC addresses allowed on the UNI port for the
second attachment circuit (AC2).
•
AC2-UNI Aging—Length of time, in seconds, that MAC addresses can stay in the UNI port security
table for the second attachment circuit (AC2).
L2 PE Service Report
The L2 PE Service report allows you to choose PEs and display their roles (for example, N-PE, U-PE or
PE-AGG) and L2-related services that are running on them.
Click the L2 PE Service Report icon to bring up the window for this report. (See Figure 13-3.)
Figure 13-3
L2 PE Service Report
Filter Values:
•
PE Role—PE device role (N-PE, U-PE, or PE-AGG).
•
PE Name—PE device name.
Output Values:
•
PE Role—PE device role (N-PE, U-PE, or PE-AGG).
•
PE Name—PE device name.
•
SR ID—Service request identification number.
•
SR Job ID—Service request job identification number.
•
SR State—Service request state.
Note
•
The SR State output does not list service requests in the CLOSED state. Service requests in
other states are listed, as determined by the filter values.
Service Type—Type of service.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
13-6
OL-21636-01
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
L2 VPN Report
The L2 VPN Report provides a way to track a VLAN ID and/or VC ID back to the VPN and customer
without having to iterate through every link and every VPN service. Given a VLAN ID or VC ID, the
respective customer and VPN details are displayed in the report.
Click the L2 VPN Report icon to bring up the window for this report. (See Figure 13-4.)
Figure 13-4
L2 VPN Report
Filter Values:
•
VLAN ID—VLAN identification number.
•
VC ID—Virtual circuit identification number.
•
Customer Name—Name of the customer.
•
Access Domain—Access domain name.
Output Values:
•
VLAN ID—VLAN identification number.
•
VC ID—Virtual circuit identification number.
•
SR Job ID—Service request job identification number
•
VPN—Name of the VPN.
•
Customer Name—Name of the customer.
•
Service Type—Type of service.
•
Access Domain—Access domain name.
•
Provider Name—Name of the provider.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
13-7
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
VPLS Attachment Circuit Report
The VPLS Attachment circuit report displays details of attachment circuits for a given customer VPN.
Click the VPLS Attachment Circuit Report icon to bring up the window for this report. (See
Figure 13-5.)
Figure 13-5
VPLS Attachment Circuit Report
Filter Values:
•
SR ID—Service request identification number.
•
SR Job ID—Service request job identification number.
•
SR State—Service request state. Values can be:
– BROKEN
– DEPLOYED
– FAILED_AUDIT
– FAILED_DEPLOY
– FUNCTIONAL
– INVALID
– LOST
– PENDING
– REQUESTED
– WAIT_DEPLOY
•
Customer Name—Name of the customer.
•
VPN—Name of the VPN.
•
Service Type—Type of service. Values can be:
– VPLS_ERS
– VPLS_ERS_NO_CE
– VPLS_EWS
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
13-8
OL-21636-01
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
– VPLS_EWS_NO_CE
•
VLAN ID—VLAN identification number.
•
AccessDomain—Access domain name.
Output Values:
•
VPLS Link ID—VPLS link identification number.
•
SR ID—Service request identification number
•
SR Job ID—Service request job identification number.
•
SR State—Service request state.
Note
The SR State output does not list service requests in the CLOSED state. Service requests in
other states are listed, as determined by the filter values.
•
Customer Name—Name of the customer.
•
VPN—Name of the VPN.
•
Service Type—Type of service.
•
VLAN ID—VLAN identification number.
•
Policy Name—Name of the VPLS policy.
•
VFI Interface—Virtual forwarding interface name.
•
Customer Facing UNI—Customer-facing UNI port.
•
AccessDomain—Access domain name.
•
NPC—Named physical circuit.
•
UNI Port—UNI port.
•
UNI Shutdown—Shutdown status of the UNI port.
•
UNI Aging—Length of time, in seconds, that MAC addresses can stay in the UNI port security
table.
•
UNI Speed—UNI port speed.
•
UNI Duplex—Duplex status (none, full, half, or auto) of the UNI port.
•
Maximum MAC Address—Maximum MAC addresses allowed on the UNI port.
•
CDP Shutdown Threshold—Cisco Discovery Protocol shutdown threshold (in packets/second) on
the UNI port.
•
STP Shutdown Threshold—Spanning Tree Protocol shutdown threshold (in packets/second) on
the UNI port.
•
VTP Shutdown Threshold—VLAN Trunk Protocol shutdown threshold (in packets/second) on the
UNI port.
•
CDP Drop Threshold—Cisco Discovery Protocol drop threshold (in packets/second) on the UNI
port.
•
VTP Drop Threshold—VLAN Trunk Protocol drop threshold (in packets/second) on the UNI port.
•
STP Drop Threshold—Spanning Tree Protocol drop threshold (in packets/second) on the UNI port.
•
Recovery Interval—Recovery interval (in seconds) of the UNI port.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
13-9
Chapter 13
Generating L2 and VPLS Reports
L2 and VPLS Reports
VPLS PE Service Report
The VPLS PE Service report allows you to choose PEs and display their roles (for example, N-PE, U-PE
or PE-AGG) and the VPLS services that are running on them.
Click the VPLS PE Service Report icon to bring up the window for this report. (See Figure 13-6.)
Figure 13-6
VPLS PE Service Report
Filter Values:
•
PE Role—PE device role (N-PE, U-PE, or PE-AGG).
•
PE Name—PE device name.
Output Values:
•
PE Role—PE device role (N-PE, U-PE, or PE-AGG).
•
PE Name—PE device name.
•
SR ID—Service request identification number.
•
SR Job ID—Service request job identification number.
•
Service Type—Type of service.
•
SR State—Service request state.
Note
The SR State output does not list service requests in the CLOSED state. Service requests in
other states are listed, as determined by the filter values.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
13-10
OL-21636-01
Chapter 13
Generating L2 and VPLS Reports
Creating Custom L2 and VPLS Reports
VPLS VPN Report
The VPLS VPN report provides a way to track a VLAN ID and/or VFI Name back to the VPN and
customer without having to iterate through every link and every VPN service. Given a VLAN ID or VFI
name, the respective customer and VPN details are displayed in the report.
Click the VPLS VPN Report icon to bring up the window for this report. (See Figure 13-7.)
Figure 13-7
VPLS VPN Report
Filter Values:
•
VLAN ID—VLAN identification number.
•
Customer Name—Name of the customer.
•
VFI Name—Virtual forwarding interface name.
•
Access Domain—Access domain name.
Output Values:
•
VLAN ID—VLAN identification number.
•
SR Job ID—Service request job identification number.
•
VPN—Name of the VPN.
•
Customer Name—Name of the customer.
•
Service Type—Type of service.
•
VFI Name—Virtual forwarding interface name.
•
Access Domain—Access domain name.
•
Provider Name—Name of the provider.
Creating Custom L2 and VPLS Reports
The reports listed in the ISC GUI in the L2 folder are derived from an underlying configuration file. The
file is in XML format. You can access the file in the following location:
$ISC_HOME/resources/nbi/reports/ISC/l2_report.xml
See the “Monitoring” chapter in Cisco IP Solution Center Infrastructure Reference, 6.0 for details on
how to modify report configuration files to create custom reports.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
13-11
Chapter 13
Generating L2 and VPLS Reports
Creating Custom L2 and VPLS Reports
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
13-12
OL-21636-01
A P P E N D I X
A
Sample Configlets
This appendix provides sample configlets for L2VPN and Metro Ethernet service provisioning in ISC.
It contains the following sections:
•
Overview, page A-2
•
ERS (EVPL) (Point-to-Point), page A-4
•
ERS (EVPL) (Point-to-Point, UNI Port Security), page A-5
•
ERS (EVPL) (1:1 VLAN Translation), page A-7
•
ERS (EVPL) (2:1 VLAN Translation), page A-8
•
ERS (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device), page A-9
•
ERS (EVPL) (NBI Enhancements for L2VPN, IOS Device), page A-10
•
ERS (EVPL) or EWS (EPL) (IOS XR Device), page A-11
•
ERS (EVPL) and EWS (EPL) (Local Connect on E-Line), page A-14
•
ERS (EVPL), EWS (EPL), ATM, or Frame Relay (Additional Template Variables for L2VPN, IOS
and IOS XR Device), page A-15
•
EWS (EPL) (Point-to-Point), page A-16
•
EWS (EPL) (Point-to-Point, UNI Port Security, BPDU Tunneling), page A-17
•
EWS (EPL) (Hybrid), page A-19
•
EWS (EPL) (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device), page A-22
•
EWS (EPL) (NBI Enhancements for L2VPN, IOS Device), page A-23
•
ATM over MPLS (VC Mode), page A-24
•
ATM over MPLS (VP Mode), page A-25
•
ATM (Port Mode, Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device), page A-26
•
Frame Relay over MPLS, page A-27
•
Frame Relay (DLCI Mode), page A-28
•
VPLS (Multipoint, ERMS/EVP-LAN), page A-29
•
VPLS (Multipoint, EMS/EP-LAN), BPDU Tunneling), page A-30
•
FlexUNI/EVC (Pseudowire Core Connectivity, UNI Port Security), page A-31
•
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, without Port Security, with Bridge Domain),
page A-32
•
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, and Pseudowire Tunneling), page A-33
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-1
Appendix A
Sample Configlets
Overview
•
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, and Pseudowire Tunneling), page A-33
•
FlexUNI/EVC (VPLS Core Connectivity, UNI Port Security), page A-34
•
FlexUNI/EVC (VPLS Core Connectivity, no UNI Port Security), page A-35
•
FlexUNI/EVC (Local Connect Core Connectivity, UNI Port Security), page A-36
•
FlexUNI/EVC (Local Connect Core Connectivity, UNI, no Port Security, Bridge Domain),
page A-38
•
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge Domain, Pseudowire on SVI), page A-39
•
FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge Domain, no Pseudowire on SVI),
page A-40
•
FlexUNI/EVC (No AutoPick Service Instance Name, No Service Instance Name), page A-42
•
FlexUNI/EVC (User-Provided Service Instance Name, Pseudowire Core Connectivity), page A-43
•
FlexUNI/EVC (User-Provided Service Instance Name, Local Core Connectivity), page A-44
•
FlexUNI/EVC (User-Provided Service Instance Name, VPLS Core Connectivity), page A-45
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Point-to-Point
Circuit), page A-46
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Multipoint Circuit),
page A-47
•
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit),
page A-48
•
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Multipoint Circuit),
page A-49
•
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Multipoint Circuit),
page A-50
•
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit),
page A-51
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit),
page A-52‘
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Multipoint Circuit),
page A-53
•
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit),
page A-54
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit,
with Bridge Domain), page A-55
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit,
with Bridge Domain), page A-56
•
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, no
Bridge Domain), page A-57
Overview
The configlets provided in this appendix show the CLIs generated by ISC for particular services and
features. Each configlet example provides the following information:
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-2
OL-21636-01
Appendix A
Sample Configlets
Overview
•
Service
•
Feature
•
Devices configuration (network role, hardware platform, relationship of the devices and other
relevant information)
•
Sample configlets for each device in the configuration
•
Comments
Note
The configlets generated by ISC are only the delta between what needs to be provisioned and what
currently exists on the device. This means that if a relevant CLI is already on the device, it does not show
up in the associated configlet.
Note
The CLIs shown in bold are the most relevant commands.
Note
All examples in this appendix assume an MPLS core.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-3
Appendix A
Sample Configlets
ERS (EVPL) (Point-to-Point)
ERS (EVPL) (Point-to-Point)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL) (point-to-point).
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BXL.
Interface(s): FA8/17.
– The U-PE is a Cisco 3750ME with 12.2(25)EY1, no port security.
Interface(s): FA1/0/4 – FA1/0/23.
– L2VPN point-to-point.
Configlets
Comments
U-PE
N-PE
vlan 772
exit
!
interface FastEthernet1/0/23
switchport trunk allowed vlan 500,772
!
interface FastEthernet1/0/4
no cdp enable
no keepalive
no ip address
switchport trunk allowed vlan 500,772
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet1/0/4 in
!
mac access-list extended
ISC-FastEthernet1/0/4
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
vlan 772
exit
!
interface FastEthernet8/17
switchport trunk allowed vlan
1,451,653,659,766-768,772,878
!
interface Vlan772
no ip address
description L2VPN ERS
xconnect 99.99.8.99 89027 encapsulation
mpls
no shutdown
•
The N-PE is a 7600 with an OSM or SIP-600 module.
•
The U-PE is a generic Metro Ethernet (ME) switch. Customer BPDUs are blocked by the PACL.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-4
OL-21636-01
Appendix A
Sample Configlets
ERS (EVPL) (Point-to-Point, UNI Port Security)
ERS (EVPL) (Point-to-Point, UNI Port Security)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL) (point-to-point) with UNI port security.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, OSM.
Interface(s): FA2/18.
– The U-PE is a Cisco 3550 with IOS 12.2(25)SEC2. Port security is enabled.
Interface(s): FA3/31– FA3/23.
– L2VPN point-to-point.
Configlets
Comments
U-PE
N-PE
vlan 788
exit
!
interface FastEthernet3/23
no ip address
switchport trunk allowed vlan 783,787-788
!
interface FastEthernet3/31
no cdp enable
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 788
switchport port-security
switchport nonegotiate
switchport port-security maximum 45
switchport port-security aging time 34
switchport port-security violation shutdown
switchport port-security mac-address
3456.3456.5678
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/31 in
!
mac access-list extended
ISC-FastEthernet3/31
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
deny any host 1234.3234.3432
permit any any
vlan 788
exit
!
interface FastEthernet2/18
switchport trunk allowed vlan
350,351,430,630,777,780,783,785-788
!
interface Vlan788
no ip address
description L2VPN ERS with UNI port
security
xconnect 99.99.5.99 89028 encapsulation
mpls
no shutdown
•
The N-PE is a 7600 with an OSM or SIP-600 module.
•
The U-PE is a generic Metro Ethernet (ME) switch. The customer BPDUs are blocked by the PACL.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-5
Appendix A
Sample Configlets
ERS (EVPL) (Point-to-Point, UNI Port Security)
•
Various UNI port security commands are provisioned.
•
A user-defined PACL entry is added to the default PACL.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-6
OL-21636-01
Appendix A
Sample Configlets
ERS (EVPL) (1:1 VLAN Translation)
ERS (EVPL) (1:1 VLAN Translation)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL) with 1:1 VLAN translation.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BXL
Interface(s): FA8/34.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY1. VLAN translation on the NNI port
(uplink).
Interface(s): FA1/0/8 – GI1/1/1.
– L2VPN point-to-point.
Configlets
Comments
U-PE
N-PE
!
vlan 123
exit
!
interface FastEthernet1/0/8
no cdp enable
no keepalive
no ip address
switchport trunk allowed vlan 123
switchport nonegotiate
switchport port-security maximum 34
switchport port-security aging time 23
switchport port-security violation protect
switchport port-security
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet1/0/8 in
!
interface GigabitEthernet1/1/1
no ip address
switchport mode trunk
switchport trunk allowed vlan 1,123
switchport vlan mapping 123 778
vlan 778
exit
!
interface FastEthernet8/34
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 1,778
!
interface Vlan778
no ip address
description L2VPN ERS 1 to 1 vlan
translation
xconnect 99.99.8.99 89032 encapsulation
mpls
no shutdown
•
VLAN translation is only for L2VPN (point-to-point) ERS (EVPL).
•
In this case, the 1:1 VLAN translation occurs on the U-PE, a 3750. It is provisioned on the NNI
(uplink) port.
•
The customer VLAN 123 is translated to the provider VLAN 778.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-7
Appendix A
Sample Configlets
ERS (EVPL) (2:1 VLAN Translation)
ERS (EVPL) (2:1 VLAN Translation)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL) with VLAN 2:1 translation.Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BXL
Interface(s): FA8/34.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY1. VLAN translation on the NNI port
(uplink).
Interface(s): FA1/0/5 – GI1/1/1.
– L2VPN point-to-point.
Configlets
Comments
U-PE
N-PE
vlan 567
exit
!
interface FastEthernet1/0/5
no cdp enable
no keepalive
no ip address
switchport
switchport access vlan 567
switchport mode dot1q-tunnel
switchport trunk allowed vlan none
switchport nonegotiate
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet1/0/5 in
!
interface GigabitEthernet1/1/1
no ip address
switchport trunk allowed vlan 1,123,567
switchport vlan mapping dot1q-tunnel 567
234 779
!
mac access-list extended
ISC-FastEthernet1/0/5
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
vlan 779
exit
!
interface FastEthernet8/34
switchport trunk allowed vlan 1,778-779
!
interface Vlan779
no ip address
description L2VPN ERS 2 to 1 vlan
translation
xconnect 99.99.8.99 89033 encapsulation
mpls
no shutdown
•
VLAN translation is only for L2VPN (point-to-point) ERS (EVPL).
•
In this case, the 2:1 VLAN translation occurs on the U-PE, a 3750. It is provisioned on the NNI
(uplink) port.
•
The customer VLAN 123 and the provider VLAN 234 (as part of Q -in-Q) are translated to a new
provider VLAN 779.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-8
OL-21636-01
Appendix A
Sample Configlets
ERS (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device)
ERS (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR
Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL).
•
Device configuration:
– The N-PE is a CRS-1 with IOS XR 3.6.1 or later.
– UNI on N-PE.
– UNI on U-PE.
Configlets
Comments
U-PE
N-PE
!
vlan 700
exit
!
interface FastEthernet1/0/2
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 700
switchport mode trunk
switchport nonegotiate
no keepalive
mac access-group ISC-FastEthernet1/0/2 in
no cdp enable
spanning-tree bpdufilter enable
!
!
interface GigabitEthernet1/0/1
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 700
switchport mode trunk
keepalive 10
!
!
mac access-list extended
ISC-FastEthernet1/0/2
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
!
!
interface GigabitEthernet0/3/1/1.700
l2transport
dot1q vlan 700
!
l2vpn
pw-class PW_AD3-AD7_Customer1
encapsulation mpls
transport-mode vlan
preferred-path interface tunnel-te 1370
fallback disable
!
!
xconnect group L2VPN_Customer1-Gold_class
p2p GoldPkg_AD3-AD7_Customer1
interface GigabitEthernet0/3/1/1.700
neighbor 192.169.105.30 pw-id 1000
pw-class PW_AD3-AD7_Customer1
!
!
•
The N-PE is a CRS-1 with IOS XR 3.7.
•
The pseudowire class feature is configured with various associated attributes like encapsulation,
transport mode, preferred-path, and fallback option.
•
The disable fallback option is required for IOS XR 3.6.1 and optional for IOS XR 3.7 and later.
•
The E-Line name (p2p command) and L2VPN Group Name (xconnect group command) is user
configured.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-9
Appendix A
Sample Configlets
ERS (EVPL) (NBI Enhancements for L2VPN, IOS Device)
ERS (EVPL) (NBI Enhancements for L2VPN, IOS Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL).
•
Device configuration:
– The N-PE is a 12.2(18)SXF with IOS.
– The U-PE is a 12.2(25)EY4with IOS.
– UNI on N-PE.
– UNI on U-PE.
Configlets
Comments
U-PE
N-PE
!
vlan 3200
exit
!
interface FastEthernet1/0/2
no cdp enable
no ip address
duplex auto
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 3200
switchport nonegotiate
switchport port-security aging type
inactivity
switchport port-security maximum 100
switchport port-security aging time 1000
switchport port-security violation protect
switchport port-security
storm-control unicast level 1.0
storm-control broadcast level 50.0
storm-control multicast level 50.0
shutdown
keepalive
spanning-tree bpdufilter enable
!
vlan 3300
exit
!
interface FastEthernet1/0/24
no cdp enable
no ip address
duplex auto
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 3300
switchport nonegotiate
switchport port-security aging type
inactivity
switchport port-security maximum 100
switchport port-security aging time 1000
switchport port-security violation protect
switchport port-security
storm-control unicast level 1.0
storm-control broadcast level 50.0
storm-control multicast level 50.0
shutdown
keepalive
spanning-tree bpdufilter enable
!
interface GigabitEthernet1/0/1
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 3200
!
!
interface Vlan3300
no ip address
xconnect 192.169.105.40 7502 encapsulation
mpls
no shutdown
!
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-10
OL-21636-01
Appendix A
Sample Configlets
ERS (EVPL) or EWS (EPL) (IOS XR Device)
ERS (EVPL) or EWS (EPL) (IOS XR Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL) or EWS (EPL).
•
Device configuration(s):
– The N-PE is a CRS-1 with IOS XR 3.4.2.
– UNI on N-PE. ERS (EVPL) only.
– U-PE. EWS (EPL) or ERS (EVPL).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-11
Appendix A
Sample Configlets
ERS (EVPL) or EWS (EPL) (IOS XR Device)
Configlets
N-PE
<?xml version="1.0" encoding="UTF-8"?>
<Request MajorVersion="1" MinorVersion="0">
<Set>
<Configuration Source="CurrentConfig">
<InterfaceConfigurationTable>
<InterfaceConfiguration>
<Naming>
<Name>GigabitEthernet0/0/0/1.302</Name>
<Active>act</Active>
</Naming>
<InterfaceModeNonPhysical>L2Transport</InterfaceModeNonPhysical>
</InterfaceConfiguration>
</InterfaceConfigurationTable>
<L2VPN>
<Enabled>true</Enabled>
<XConnectGroupTable>
<XConnectGroup>
<Naming>
<Name>VPNSC</Name>
</Naming>
<Enabled>true</Enabled>
<P2PXConnectTable>
<P2PXConnect>
<Naming>
<Name>GigabitEthernet0_0_0_1.302</Name>
</Naming>
<Enabled>true</Enabled>
<AttachmentCircuitTable>
<AttachmentCircuit>
<Naming>
<Name>GigabitEthernet0/0/0/1.302</Name>
</Naming>
<Enabled>true</Enabled>
</AttachmentCircuit>
</AttachmentCircuitTable>
<PseudoWireTable>
<PseudoWire>
<Naming>
<Neighbor>
<IPV4Address>10.11.13.15</IPV4Address>
</Neighbor>
<PseudowireID>1005</PseudowireID>
</Naming>
<PseudoWireParameters/>
</PseudoWire>
</PseudoWireTable>
</P2PXConnect>
</P2PXConnectTable>
</XConnectGroup>
</XConnectGroupTable>
</L2VPN>
</Configuration>
</Set>
<Commit/>
</Request>
Comments
•
In IOS XR, device configuration is specified in XML format.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-12
OL-21636-01
Appendix A
Sample Configlets
ERS (EVPL) or EWS (EPL) (IOS XR Device)
•
With respect to the XML schemas, different versions of IOS XR generate different XML configlets.
However the configurations will be almost identical, except for changes in the XML schema.
•
There are different cases to consider. For example, when a service request is decommissioned or
modified, the XML configuration will slightly differ.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-13
Appendix A
Sample Configlets
ERS (EVPL) and EWS (EPL) (Local Connect on E-Line)
ERS (EVPL) and EWS (EPL) (Local Connect on E-Line)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL) and EWS (EPL).
•
Device configuration:
– The N-PE is a CRS-1 with IOS XR 3.6 or later.
– The U-PE is a 12.2(18)SXF with IOS.
Configlets
U-PE
N-PE
interface GigabitEthernet0/0/0/2.559
dot1q vlan 559
l2transport
!
interface GigabitEthernet0/0/0/4.559
dot1q vlan 559
l2transport
!
l2vpn
xconnect group ISC
p2p cl-test-l2-crs1-1--0--559
interface GigabitEthernet0/0/0/2.559
interface GigabitEthernet0/0/0/4.559
!
!
!
Comments
•
The default E-Line name has changed for local connect configlets.
•
The format of the default E-line name is:
device_name_with_underscores--VCID--VLANID
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-14
OL-21636-01
Appendix A
Sample Configlets
ERS (EVPL), EWS (EPL), ATM, or Frame Relay (Additional Template Variables for L2VPN, IOS and IOS XR Device)
ERS (EVPL), EWS (EPL), ATM, or Frame Relay (Additional
Template Variables for L2VPN, IOS and IOS XR Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ERS (EVPL), EWS (EPL), ATM and Frame Relay.
•
Device configuration:
– The N-PE is a 12.2(18)SXF with IOS for ERS (EVPL), EWS (EPL), Frame Relay service.
– The N-PE is a CRS-1 with IOS XR 3.6 or later for ERS (EVPL), EWS (EPL) service; and IOS
XR 3.7 or later for ATM service (ATM port mode).
– The U-PE is a 12.2(25)EY4 with IOS for ERS (EVPL) or EWS (EPL) service.
Configlets
U-PE
N-PE
(None)
Template Content:
interface Loopback0
description
LocalLoopbackAddress=$L2VPNLocalLoopback
LocalHostName=$L2VPNLocalHostName
RemoteLoopbackAddress=$L2VPNRemoteLoopback
RemoteHostName=$L2VPNRemoteHostName
Configlets:
interface Loopback0
description LocalLoopbackAddress=
192.169.105.40
LocalHostName=cl-test-l2-7600-2
RemoteLoopbackAddress=192.169.105.80
RemoteHostName= cl-test-l2-7600-4
Comments
•
These four variables are supported only on the N-PE.
•
The values will be empty for all other device roles (U-PE, PE-AGG, and CE).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-15
Appendix A
Sample Configlets
EWS (EPL) (Point-to-Point)
EWS (EPL) (Point-to-Point)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: EWS (EPL) (point-to-point).
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BXL.
Interface(s): FA8/17.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY1. No port security, no tunneling.
Interface(s): FA1/0/20 – FA1/0/23.
– L2VPN point-to-point.
– Q-in-Q UNI.
Configlets
Comments
U-PE
N-PE
system mtu 1522
!
vlan 774
exit
!
interface FastEthernet1/0/20
no cdp enable
no keepalive
switchport
switchport access vlan 774
switchport mode dot1q-tunnel
switchport nonegotiate
spanning-tree portfast
spanning-tree bpdufilter enable
!
interface FastEthernet1/0/23
no ip address
switchport trunk allowed vlan 774,787-788
vlan 774
exit
!
interface FastEthernet8/17
switchport trunk allowed vlan
1,451,653,659,766-768,772,773-774,878
!
interface Vlan774
no ip address
description L2VPN EWS
xconnect 99.99.8.99 89029 encapsulation
mpls
no shutdown
•
The N-PE is a 7600 with a OSM or SIP-600 module. Provisioning is the same as the ERS (EVPL)
example.
•
The U-PE is a generic Metro Ethernet (ME) switch.
•
No PACL provisioned by default. BPDU can be tunneled if desired.
•
The system MTU needs to set to 1522 to handle the extra 4 bytes of Q-in-Q frames.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-16
OL-21636-01
Appendix A
Sample Configlets
EWS (EPL) (Point-to-Point, UNI Port Security, BPDU Tunneling)
EWS (EPL) (Point-to-Point, UNI Port Security, BPDU Tunneling)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: EWS (EPL) (point-to-point) with Port security, BPDU tunneling.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BXL.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY1. No port security, with tunneling.
– L2VPN point-to-point.
– Q-in-Q UNI.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-17
Appendix A
Sample Configlets
EWS (EPL) (Point-to-Point, UNI Port Security, BPDU Tunneling)
Configlets
U-PE
N-PE
system mtu 1522
!
vlan 775
exit
!
system mtu 1522
!
vlan 775
exit
!
interface FastEthernet1/0/19
no cdp enable
no keepalive
switchport
switchport access vlan 775
switchport mode dot1q-tunnel
switchport nonegotiate
switchport port-security maximum 34
switchport port-security aging time 32
switchport port-security violation shutdown
switchport port-security
l2protocol-tunnel cdp
l2protocol-tunnel stp
l2protocol-tunnel vtp
l2protocol-tunnel shutdown-threshold cdp 88
l2protocol-tunnel shutdown-threshold stp 99
l2protocol-tunnel shutdown-threshold vtp 56
l2protocol-tunnel drop-threshold cdp 56
l2protocol-tunnel drop-threshold stp 64
l2protocol-tunnel drop-threshold vtp 34
storm-control unicast level 34.0
storm-control broadcast level 23.0
storm-control multicast level 12.0
spanning-tree portfast
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet1/0/19 in
vlan 775
exit
!
interface FastEthernet8/17
switchport trunk allowed vlan
1,451,653,659,766-768,772,773-775,878
!
interface Vlan775
no ip address
description L2VPN EWS
xconnect 99.99.8.99 89029 encapsulation
mpls
no shutdown
interface FastEthernet1/0/23
no ip address
switchport trunk allowed vlan
774-775,787-788
!
mac access-list extended
ISC-FastEthernet1/0/19
no permit any any
deny any host 3456.3456.1234
permit any any
Comments
•
The N-PE is a 7600 with an OSM or SIP-600 module. Provisioning is the same as the ERS (EVPL)
example.
•
The U-PE is a generic Metro Ethernet (ME) switch.
•
PACL with one user-defined entry.
•
BPDUs (CDP, STP and VTP) are tunneled through the MPLS core.
•
Storm control is enabled for unicast, multicast, and broadcast.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-18
OL-21636-01
Appendix A
Sample Configlets
EWS (EPL) (Hybrid)
EWS (EPL) (Hybrid)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: EWS (EPL) hybrid. One side is EWS (EPL) UNI; the other side is ERS (EVPL) NNI.
•
Device configuration:
– The N-PE is a Cisco 7600 with 12.2(18)SXF, Sup720-3BXL.
Interface(s): FA8/17.
– The U-PE is a Cisco 3750ME with 12.2(25)EY1. No port security, with tunneling.
Interface(s): FA1/0/20 – FA1/0/23.
– L2VPN point-to-point.
– Q-in-Q UNI.
Note
The first configlet example is the EWS (EPL) side (UNI). The second configlet is the ERS (EVPL) side
(NNI).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-19
Appendix A
Sample Configlets
EWS (EPL) (Hybrid)
Configlets (EWS)
U-PE
N-PE
system mtu 1522
!
vlan 775
exit
!
system mtu 1522
!
vlan 775
exit
!
interface FastEthernet1/0/19
no cdp enable
no keepalive
switchport
switchport access vlan 775
switchport mode dot1q-tunnel
switchport nonegotiate
switchport port-security maximum 34
switchport port-security aging time 32
switchport port-security violation shutdown
switchport port-security
l2protocol-tunnel cdp
l2protocol-tunnel stp
l2protocol-tunnel vtp
l2protocol-tunnel shutdown-threshold cdp 88
l2protocol-tunnel shutdown-threshold stp 99
l2protocol-tunnel shutdown-threshold vtp 56
l2protocol-tunnel drop-threshold cdp 56
l2protocol-tunnel drop-threshold stp 64
l2protocol-tunnel drop-threshold vtp 34
storm-control unicast level 34.0
storm-control broadcast level 23.0
storm-control multicast level 12.0
spanning-tree portfast
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet1/0/19 in
vlan 775
exit
!
interface FastEthernet8/17
switchport trunk allowed vlan
1,451,653,659,766-768,772,773-775,878
!
interface Vlan775
no ip address
description L2VPN EWS
xconnect 99.99.8.99 89029 encapsulation
mpls
no shutdown
interface FastEthernet1/0/23
no ip address
switchport trunk allowed vlan
774-775,787-788
!
mac access-list extended
ISC-FastEthernet1/0/19
no permit any any
deny any host 3456.3456.1234
permit any any
Comments
•
This is the EWS (EPL) side (UNI).
•
N-PE is 7600 with an OSM or a SIP-600 module. Provisioning is the same as the ERS (EVPL).
•
The U-PE is a generic Metro Ethernet (ME) switch.
•
PACL with one user-defined entry.
•
BPDUs (cdp, stp and vtp) are tunneled through the MPLS core.
•
Storm control is enabled for unicast, multicast, and broadcast.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-20
OL-21636-01
Appendix A
Sample Configlets
EWS (EPL) (Hybrid)
Configlets (ERS)
U-PE
N-PE
system mtu 1522
vlan 775
exit
!
interface FastEthernet8/17
switchport trunk allowed vlan
1,451,653,659,766-768,772,773-775,878
!
interface Vlan775
no ip address
description L2VPN EWS
xconnect 99.99.8.99 89029 encapsulation
mpls
no shutdown
vlan 775
exit
interface FastEthernet1/17
switchport trunk allowed vlan
1,451,653,659,766-768,772,773-775,878
interface FastEthernet1/10
switchport trunk allowed vlan
1,451,653,659,766-768,772,773-775,878
Comments
•
This is the ERS (EVPL) side (NNI).
•
The N-PE is a 7600 with an OSM or a SIP-600 module. Provisioning is the same as the ERS (EVPL).
•
The U-PE is really a PE-AGG. It connects to the wholesale customer as an NNI. Both ports are
regular NNI ports.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-21
Appendix A
Sample Configlets
EWS (EPL) (Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device)
EWS (EPL) (Pseudowire Class, E-Line, L2VPN Group Name, IOS
XR Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: EWS (EPL).
•
Device configuration:
– The N-PE is a CRS-1 with IOS XR 3.6.1 or later.
– UNI on U-PE.
Configlets
Comments
U-PE
N-PE
!
system mtu 1522
!
vlan 700
exit
!
interface FastEthernet1/0/2
switchport
switchport access vlan 700
switchport mode dot1q-tunnel
switchport nonegotiate
no keepalive
no cdp enable
spanning-tree portfast
spanning-tree bpdufilter enable
!
interface GigabitEthernet1/0/1
no ip address
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 700
switchport mode trunk
!
!
interface GigabitEthernet0/3/1/1.700
l2transport
dot1q vlan 700
!
!
l2vpn
pw-class PW_AD7-AD3_Cutsomer2
encapsulation mpls
transport-mode ethernet
preferred-path interface tunnel-te 2730
!
!
xconnect group ISC
p2p cl-test-l2-12404-2--1000
interface GigabitEthernet0/3/1/1.700
neighbor 192.169.105.30 pw-id 1000
pw-class PW_AD7-AD3_Cutsomer2
!
•
The N-PE is a CRS-1 router with IOS XR 3.7.
•
The pseudowire class feature is configured with various associated attributes like encapsulation,
transport mode, preferred-path, and fallback option
•
The disable fallback option is required for IOS XR 3.6.1 and optional for IOS XR 3.7 and later.
•
The E-Line name (p2p command) and L2VPN Group Name (xconnect group command) is an
ISC-generated default value, if user input is not provided.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-22
OL-21636-01
Appendix A
Sample Configlets
EWS (EPL) (NBI Enhancements for L2VPN, IOS Device)
EWS (EPL) (NBI Enhancements for L2VPN, IOS Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: EWS (EPL).
•
Device configuration:
– The N-PE is a 12.2(18)SXF with IOS.
– The U-PE is a 12.2(25)EY4with IOS.
– UNI on N-PE.
– UNI on U-PE.
Configlets
Comments
U-PE
N-PE
!
vlan 3201
exit
!
interface FastEthernet1/0/2
no cdp enable
no ip address
duplex auto
switchport
switchport access vlan 3201
switchport mode dot1q-tunnel
switchport nonegotiate
switchport port-security aging type
inactivity
switchport port-security maximum 100
switchport port-security aging time 1000
switchport port-security violation protect
switchport port-security
storm-control unicast level 1.0
storm-control broadcast level 50.0
storm-control multicast level 50.0
shutdown
keepalive
spanning-tree bpdufilter enable
!
vlan 3301
exit
!
interface FastEthernet1/0/24
no cdp enable
no ip address
duplex auto
switchport
switchport access vlan 3301
switchport mode dot1q-tunnel
switchport nonegotiate
switchport port-security aging type
inactivity
switchport port-security maximum 100
switchport port-security aging time 1000
switchport port-security violation protect
switchport port-security
storm-control unicast level 1.0
storm-control broadcast level 50.0
storm-control multicast level 50.0
shutdown
keepalive
spanning-tree bpdufilter enable
!
interface GigabitEthernet1/0/1
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 3201
!
!
interface Vlan3301
no ip address
xconnect 192.169.105.40 7502 encapsulation
mpls
no shutdown
!
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-23
Appendix A
Sample Configlets
ATM over MPLS (VC Mode)
ATM over MPLS (VC Mode)
Configuration
•
Service: L2VPN.
•
Feature: ATM over MPLS (ATMoMPLS, a type of AToM) in VC mode.
•
Device configuration:
– The N-PE is a Cisco 7200 with IOS 12.0(28)S.
– No CE.
– No U-PE.
– L2VPN point-to-point (ATMoMPLS).
– C7200 (ATM2/0).
Configlets
Comments
U-PE
N-PE
(None)
interface ATM2/0.34234 point-to-point
pvc 213/423 l2transport
encapsulation aal5
xconnect 99.99.4.99 89025 encapsulation
mpls
•
The N-PE is any MPLS-enabled router.
•
L2VPN provisioning is on the ATM VC connection.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-24
OL-21636-01
Appendix A
Sample Configlets
ATM over MPLS (VP Mode)
ATM over MPLS (VP Mode)
Configuration
•
Service: L2VPN.
•
Feature: ATM over MPLS (ATMoMPLS, a type of AToM) in VP mode.
•
Device configuration:
– The N-PE is a Cisco 7200 with IOS 12.0(28)S.
Interface(s): ATM2/0.
– No CE.
– No U-PE.
– L2VPN point-to-point (ATMoMPLS).
Configlets
Comments
U-PE
N-PE
(None)
pseudowire-class ISC-pw-tunnel-123
encapsulation mpls
preferred-path interface tunnel123
disable-fallback
!
interface ATM2/0
atm pvp 131 l2transport
xconnect 99.99.4.99 89024 pw-class
ISC-pw-tunnel-123
•
The N-PE is any MPLS-enabled router.
•
L2VPN provisioning is on the ATM VP connection.
•
The L2VPN pseudowire is mapped to a TE tunnel.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-25
Appendix A
Sample Configlets
ATM (Port Mode, Pseudowire Class, E-Line, L2VPN Group Name, IOS XR Device)
ATM (Port Mode, Pseudowire Class, E-Line, L2VPN Group
Name, IOS XR Device)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: ATM.
•
Device configuration:
– The N-PE is a CRS-1 with IOS XR 3.7 or later for ATM service (port mode only).
– UNI on N-PE.
Configlets
Comments
U-PE
N-PE
(None)
interface ATM0/1/0/0
description UNIDesc_AC1
l2transport
!
!
l2vpn
pw-class PWClass-1
encapsulation mpls
preferred-path interface tunnel-te 500
fallback disable
!
!
xconnect group ISC
p2p ELine_AC1
interface ATM0/1/0/0
neighbor 192.169.105.70 pw-id 100
pw-class PWClass-1
!
•
The N-PE is a CRS-1 router.
•
The pseudowire class feature is optional and not configured.
•
The E-Line name (p2p command) and L2VPN Group Name (xconnect group command) are user
configured.
•
Only PORT mode is supported in IOS XR.
•
This PORT mode will not generate any specific command, such as pvp or pvc, on IOS XR devices.
•
The ATM interface is included under xconnect.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-26
OL-21636-01
Appendix A
Sample Configlets
Frame Relay over MPLS
Frame Relay over MPLS
Configuration
•
Service: L2VPN.
•
Feature: Frame Relay over MPLS (FRoMPLS, a type of AToM).
•
Device configuration:
– The N-PE is a Cisco 7200 with IOS 12.0(28)S.
Interface(s): ATM2/0.
– No CE.
– No U-PE.
– L2VPN point-to-point (ATMoMPLS).
Configlets
Comments
U-PE
N-PE
(None)
interface Serial1/1
exit
!
connect C1_89001 Serial1/1 135 l2transport
xconnect 99.99.4.99 89001 encapsulation
mpls
•
The N-PE is any MPLS-enabled router.
•
L2VPN provisioning is on the serial port for the Frame Relay connection.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-27
Appendix A
Sample Configlets
Frame Relay (DLCI Mode)
Frame Relay (DLCI Mode)
Configuration
•
Service: L2VPN over a L2TPv3 core.
•
Feature: FR in DLCI mode.
•
Device configuration:
– The N-PE is a Cisco 7200 with IOS 12.0(28)S.
Interface(s): ATM2/0.
– No CE.
– No U-PE.
– L2VPN point-to-point (ATMoMPLS).
Configlets
Comments
U-PE
N-PE
(None)
pseudowire-class ISC-pw-dynamic-default
encapsulation l2tpv3
ip local interface Loopback10
ip dfbit set
!
interface Serial3/2
encapsulation frame-relay
exit
!
connect ISC_1054 Serial3/2 86 l2transport
xconnect 10.9.1.1 1054 encapsulation l2tpv3
pw-class ISC-pw-dynamic-default
•
The N-PE is any L2TPv3 enabled router.
•
L2VPN provisioning is on the serial port for the Frame Relay connection.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-28
OL-21636-01
Appendix A
Sample Configlets
VPLS (Multipoint, ERMS/EVP-LAN)
VPLS (Multipoint, ERMS/EVP-LAN)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: VPLS (multipoint) ERMS (EVP-LAN).
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BX.L
Interface(s): FA2/18.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY1. No port security, no tunneling.
Interface(s): FA1/0/21 – FA1/0/23.
– VPLS Multipoint VPN with VLAN 767.
Configlets
U-PE
N-PE
vlan 767
exit
!
interface FastEthernet1/0/21
no cdp enable
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 767
switchport nonegotiate
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet1/0/21 in
!
interface FastEthernet1/0/23
no ip address
l2 vfi vpls_ers_1-0 manual
vpn id 89017
neighbor 99.99.10.9 encapsulation mpls
neighbor 99.99.5.99 encapsulation mpls
!
vlan 767
exit
!
interface FastEthernet2/18
switchport trunk allowed vlan
350,351,430,630,767,780,783,785-791
!
interface Vlan767
no ip address
description VPLS ERS
xconnect vfi vpls_ers_1-0
no shutdown
mac access-list extended
ISC-FastEthernet1/0/21
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
Comments
•
The N-PE is a 7600 with OSM or SIP-600 module.
•
The VFI contains all the N-PEs (neighbors) that this N-PE talks to.
•
The U-PE is a generic Metro Ethernet (ME) switch. The customer BPDUs are blocked by the PACL.
The VPLS ERMS (EVP-LAN) UNI is the same as the L2VPN (point-to-point) ERS (EVPL) UNI.
•
The SVI (interface 767) refers to the global VFI, which contains multiple peering N-PEs.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-29
Appendix A
Sample Configlets
VPLS (Multipoint, EMS/EP-LAN), BPDU Tunneling)
VPLS (Multipoint, EMS/EP-LAN), BPDU Tunneling)
Configuration
•
Service: L2VPN/Metro Ethernet.
•
Feature: VPLS (multipoint) EMS (EP-LAN) with BPDU tunneling.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(18)SXF, Sup720-3BXL.
Interface(s): FA2/18.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY1. No port security, no tunneling.
Interface(s): FA1/0/12 – FA1/0/23.
– VPLS Multipoint VPN, with VLAN 767.
– Q-in-Q UNI.
Configlets
Comments
U-PE
N-PE
system mtu 1522
!
errdisable recovery interval 33
!
vlan 776
exit
!
interface FastEthernet1/0/12
no cdp enable
no keepalive
switchport
switchport access vlan 776
switchport mode dot1q-tunnel
switchport nonegotiate
l2protocol-tunnel cdp
l2protocol-tunnel stp
l2protocol-tunnel vtp
l2protocol-tunnel shutdown-threshold
l2protocol-tunnel shutdown-threshold
l2protocol-tunnel shutdown-threshold
l2protocol-tunnel drop-threshold cdp
l2protocol-tunnel drop-threshold stp
l2protocol-tunnel drop-threshold vtp
no shutdown
spanning-tree portfast
spanning-tree bpdufilter enable
l2 vfi vpls_ews-89019 manual
vpn id 89019
neighbor 99.99.8.99 encapsulation mpls
!
vlan 776
exit
!
interface FastEthernet8/17
switchport trunk allowed vlan
1,451,653,659,766-768,772-776,878
!
interface Vlan776
no ip address
description VPLS EWS
xconnect vfi vpls_ews-89019
no shutdown
cdp 88
stp 64
vtp 77
34
23
45
•
The N-PE is a 7600 with an OSM or SIP-600 module.
•
The VFI contains all the N-PEs (neighbors) that this N-PE talks to.
•
The VPLS EMS (EP-LAN) UNI is the same as L2VPN (point-to-point) EWS (EPL) UNI.
•
The SVI is the same as VPLS ERS (EVP-LAN) SVI.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-30
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (Pseudowire Core Connectivity, UNI Port Security)
FlexUNI/EVC (Pseudowire Core Connectivity, UNI Port Security)
Configuration
•
Service: FlexUNI (EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity, with UNI port security.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33)SRB3.
Interface(s): GI2/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY2. Port security is enabled.
Interface(s): FA1/14– FA3/23.
Configlets
Comments
U-PE
N-PE
vlan 788
exit
!
interface FastEthernet3/23
no ip address
switchport trunk allowed vlan 783,787-788
!
interface FastEthernet1/14
no cdp enable
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 788
switchport port-security
switchport nonegotiate
switchport port-security maximum 45
switchport port-security aging time 34
switchport port-security violation shutdown
switchport port-security mac-address
3456.3456.5678
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/23 in
!
mac access-list extended
ISC-FastEthernet3/31
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
deny any host 1234.3234.3432
permit any any
interface GigabitEtherne4/0/1
no shut
service instance 10 ethernet
encapsulation dot1q 500
rewrite ingress tag push dot1q 555
symmetric
xconnect 192.169.105.20 505 encapsulation
mpls
•
UNI on U-PE.
•
Single match tag is performed.
•
The rewrite operation push pushes the outer VLAN tag of 555.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-31
Appendix A
Sample Configlets
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, without Port Security, with Bridge Domain)
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, without Port
Security, with Bridge Domain)
Configuration
•
Service: FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity, with UNI, without port security, and
with bridge domain.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33)SRB3.
Interface(s): GI2/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25)EY2. Port security is enabled.
Interface(s): FA1/14– FA3/23.
Configlets
Comments
U-PE
N-PE
vlan 772
exit
!
interface FastEthernet3/23
switchport trunk allowed vlan 500,772
!
interface FastEthernet1/14
no cdp enable
no keepalive
no ip address
switchport trunk allowed vlan 500,772
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/23 in
!
mac access-list extended
ISC-FastEthernet1/14
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
vlan 100
interface GigabitEtherne2/0/0
no shut
service instance 10 ethernet
encapsulation dot1q 500
rewrite ingress tag push dot1q 23
second-dot1q 41 symmetric
bridge-domain 100 split-horizon
•
UNI on U-PE.
•
Single match tag is performed.
•
The rewrite operation push pushes two tags.
Interface Vlan100
no shut
xconnect 192.169.105.20 101 encapsulation
mpls
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-32
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, and Pseudowire Tunneling)
FlexUNI/EVC (Pseudowire Core Connectivity, UNI, and
Pseudowire Tunneling)
Configuration
•
Service: FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity, with UNI, with pseudowire tunneling.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GI4/0/0 <–> GI2/0/0.
Configlets
U-PE
N-PE
(None)
pseudowire-class ISC-pw-tunnel-2147
encapsulation mpls
preferred-path interface Tunnel2147
disable-fallback
interface GigabitEtherne4/0/0
service instance 1 ethernet
encapsulation dot1q 11 second-dot1q 41
rewrite ingress tag pop 2 symmetric
xconnect pw-class ISC-pw-tunnel-2147
Comments
•
UNI on N-PE (the CE is directly connected).
•
Match of both tags is performed.
•
The rewrite operation pops both the inner and outer VLAN tags.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-33
Appendix A
Sample Configlets
FlexUNI/EVC (VPLS Core Connectivity, UNI Port Security)
FlexUNI/EVC (VPLS Core Connectivity, UNI Port Security)
Configuration
•
Service: FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with VPLS core connectivity, with UNI port security.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GI4/0/1.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2. Port security is enabled.
Interface(s): FA1/14– FA3/23.
Configlets
Comments
U-PE
N-PE
vlan 788
exit
!
interface FastEthernet3/23
no ip address
switchport trunk allowed vlan 783,787-788
!
interface FastEthernet1/14
no cdp enable
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 788
switchport port-security
switchport nonegotiate
switchport port-security maximum 58
switchport port-security aging time 85
switchport port-security violation shutdown
switchport port-security mac-address
1252.1254.2544
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/23 in
!
mac access-list extended
ISC-FastEthernet3/31
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
deny any host 1234.3234.3432
permit any any
l2 vfi attest-226 manual
vpn id 226
neighbor 192.169.105.20 encapsulation mpls
vlan 200
bridge-domain 200 split-horizon
interface GigabitEtherne4/0/1
no shut
service instance 10 ethernet
encapsulation dot1q 500
rewrite ingress tag translate 1-to-1 dot1q
222 symmetric
Interface vlan 200
xconnect vfi attest-226
•
UNI on U-PE.
•
The rewrite operation translates the incoming VLAN tag 500 to 222.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-34
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (VPLS Core Connectivity, no UNI Port Security)
FlexUNI/EVC (VPLS Core Connectivity, no UNI Port Security)
Configuration
•
Service: FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with VPLS core connectivity, without UNI port security.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GI4/0/1.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FA1/14– FA3/23.
Configlets
Comments
U-PE
N-PE
vlan 772
exit
!
interface FastEthernet3/23
switchport trunk allowed vlan 500,772
!
interface FastEthernet1/14
no cdp enable
no keepalive
no ip address
switchport trunk allowed vlan 500,772
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/23 in
!
mac access-list extended
ISC-FastEthernet1/14
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
l2 vfi attest1-458 manual
vpn id 452
neighbor 192.169.105.20 encapsulation mpls
vlan 200
bridge-domain 200 split-horizon
interface GigabitEtherne4/0/1
no shut
service instance 10 ethernet
encapsulation dot1q 500
rewrite ingress tag translate 1-to-2 dot1q
222 second-dot1q 41 symmetric
Interface vlan 200
xconnect vfi attest1-458
•
UNI on U-PE.
•
The rewrite operation translates the incoming VLAN tag 500 to two tags, 222 and 41.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-35
Appendix A
Sample Configlets
FlexUNI/EVC (Local Connect Core Connectivity, UNI Port Security)
FlexUNI/EVC (Local Connect Core Connectivity, UNI Port
Security)
Configuration
•
Service: FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with local connect core connectivity, with UNI port security.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s):GI2/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2. Port security is enabled.
Interface(s): FA1/14– FA3/23.
Configlets
Comments
U-PE
N-PE
vlan 788
exit
!
interface FastEthernet3/23
no ip address
switchport trunk allowed vlan 783,787-788
!
interface FastEthernet1/14
no cdp enable
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan none
switchport trunk allowed vlan 788
switchport port-security
switchport nonegotiate
switchport port-security maximum 45
switchport port-security aging time 34
switchport port-security violation shutdown
switchport port-security mac-address
4111.4545.1211
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/23 in
!
mac access-list extended
ISC-FastEthernet3/31
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
deny any host 1234.3234.3432
permit any any
Connect Customer_1 GigabitEthernet4/0/1 10
GigabitEthernet4/0/10 25
•
UNI on U-PE.
•
Two tag matching operations are carried out.
interface GigabitEtherne4/0/1
no shut
service instance 10 ethernet
encapsulation dot1q 500
rewrite ingress tag push dot1q 555
symmetric
interface GigabitEtherne4/0/10
no shut
service instance 25 ethernet
encapsulation dot1q 500 second-dot1q 501
rewrite ingress tag translate 2-to-1 dot1q
222 symmetric
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-36
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (Local Connect Core Connectivity, UNI Port Security)
•
The rewrite operation translates two tags to a single tag.
•
Two service instances are connected through the connect command.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-37
Appendix A
Sample Configlets
FlexUNI/EVC (Local Connect Core Connectivity, UNI, no Port Security, Bridge Domain)
FlexUNI/EVC (Local Connect Core Connectivity, UNI, no Port
Security, Bridge Domain)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with local connect core connectivity, with UNI, without port security, and
with bridge domain.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s):GI2/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s):FA1/14– FA3/23.
Configlets
Comments
U-PE
N-PE
vlan 772
exit
!
interface FastEthernet3/23
switchport trunk allowed vlan 500,772
!
interface FastEthernet1/14
no cdp enable
no keepalive
no ip address
switchport trunk allowed vlan 500,772
spanning-tree bpdufilter enable
mac access-group ISC-FastEthernet3/23 in
!
mac access-list extended
ISC-FastEthernet1/14
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
interface GigabitEtherne2/0/0
no shut
service instance 10 ethernet
encapsulation dot1q 500 second-dot1q 501
rewrite ingress tag translate 2-to-2 dot1q
222 second-dot1q 41 symmetric
bridge-domain 200 split-horizon
interface GigabitEtherne2/0/10
no shut
service instance 15 ethernet
encapsulation dot1q 24
rewrite ingress tag pop 1 symmetric
bridge-domain 200 split-horizon
•
UNI on U-PE.
•
The rewrite operation maps/translates the incoming two tags into two different tags.
•
The service instances here are connected through bridge domain.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-38
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge Domain, Pseudowire on SVI)
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge Domain,
Pseudowire on SVI)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity, with bridge domain, and with
Pseudowire on SVI enabled on the N-PE.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/10.
Configlets
Comments
U-PE
N-PE
vlan 452
exit
!
interface FastEthernet1/0/10
no ip address
switchport trunk allowed vlan add 452
!
interface FastEthernet1/0/13
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 452
switchport nonegotiate
vlan 3524
exit
!
ethernet evc Customer1_253
!
interface GigabitEthernet7/0/0
service instance 3 ethernet Customer1_253
encapsulation dot1q 452
rewrite ingress tag pop 1 symmetric
bridge-domain 3524 split-horizon
!
interface Vlan3524
no ip address
description BD=T,SVI=T,Flex
xconnect 22.22.22.22 52500 encapsulation
mpls
backup peer 22.22.22.22 52501
no shutdown
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-39
Appendix A
Sample Configlets
FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge Domain, no Pseudowire on SVI)
FlexUNI/EVC (Pseudowire Core Connectivity, no Bridge Domain,
no Pseudowire on SVI)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity, bridge domain disables, and with
Pseudowire on SVI disabled on the N-PE.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/10.
Configlets
Comments
U-PE
N-PE
vlan 545
exit
!
interface FastEthernet1/0/10
no ip address
switchport trunk allowed vlan add 545
!
interface FastEthernet1/0/12
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 545
switchport nonegotiate
mac access-group ISC-FastEthernet1/0/12 in
ethernet evc Customer1_248
!
interface GigabitEthernet7/0/0
service instance 2 ethernet Customer1_248
encapsulation dot1q 545
rewrite ingress tag pop 1 symmetric
xconnect 22.22.22.22 52498 encapsulation
mpls
backup peer 22.22.22.22 52499
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-40
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (AutoPick Service Instance Name)
FlexUNI/EVC (AutoPick Service Instance Name)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with AutoPick Service Instance Name enabled and the Service Instance
Name input field left blank.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/2.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/14.
Configlets
Comments
U-PE
N-PE
!
vlan 452
exit
!
interface FastEthernet1/0/10
no ip address
switchport trunk allowed vlan add 452
!
interface FastEthernet1/0/13
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 452
switchport nonegotiate
mac access-group ISC-FastEthernet1/0/13 in
!
vlan 3524
exit
!
ethernet evc C1_1
!
interface GigabitEthernet7/0/0
service instance 3 ethernet C1_1
encapsulation dot1q 452
rewrite ingress tag pop 1 symmetric
bridge-domain 3524 split-horizon
!
interface Vlan3524
no ip address
description BD=T,SVI=T,Flex
xconnect 22.22.22.22 52500 encapsulation
mpls
backup peer 22.22.22.22 52501
no shutdown
•
The transport type is pseudowire.
•
The autopick Service Instance Name will take the value CustomerName_JobID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-41
Appendix A
Sample Configlets
FlexUNI/EVC (No AutoPick Service Instance Name, No Service Instance Name)
FlexUNI/EVC (No AutoPick Service Instance Name, No Service
Instance Name)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with AutoPick Service Instance Name not enabled and the Service Instance
Name input field left blank.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/2.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/14.
Configlets
Comments
U-PE
N-PE
!
vlan 566
exit
!
interface FastEthernet1/0/14
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 566
switchport nonegotiate
no shutdown
mac access-group ISC-FastEthernet1/0/14 in
!
interface FastEthernet1/0/18
no ip address
switchport trunk allowed vlan 566
!
mac access-list extended
ISC-FastEthernet1/0/14
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
!
interface GigabitEthernet7/0/2
service instance 43 ethernet
encapsulation dot1q 566
xconnect 1.1.1.1 453366 encapsulation mpls
•
In this example, the user does not enable AutoPick Service Instance Name and also leaves the
Service Instance Name input field blank.
•
The global command ethernet evc is not generated, while the command
service instance 43 ethernet is generated.
•
There is no Service Instance Name available and the Service Instance ID is 43.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-42
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (User-Provided Service Instance Name, Pseudowire Core Connectivity)
FlexUNI/EVC (User-Provided Service Instance Name,
Pseudowire Core Connectivity)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity and user-provided service instance name.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/10.
Configlets
Comments
U-PE
N-PE
!
vlan 452
exit
!
interface FastEthernet1/0/10
no ip address
switchport trunk allowed vlan add 452
!
interface FastEthernet1/0/13
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 452
switchport nonegotiate
mac access-group ISC-FastEthernet1/0/13 in
!
vlan 3524
exit
!
ethernet evc ServiceInst
!
interface GigabitEthernet7/0/0
service instance 3 ethernet ServiceInst
encapsulation dot1q 452
rewrite ingress tag pop 1 symmetric
bridge-domain 3524 split-horizon
!
interface Vlan3524
no ip address
description BD=T,SVI=T,Flex
xconnect 22.22.22.22 52500 encapsulation
mpls
backup peer 22.22.22.22 52501
no shutdown
•
The transport type is PSEUDOWIRE.
•
The user manually provided ServiceInst as the Service Instance Name. This is pushed onto the
device, where the Service Instance ID is 3.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-43
Appendix A
Sample Configlets
FlexUNI/EVC (User-Provided Service Instance Name, Local Core Connectivity)
FlexUNI/EVC (User-Provided Service Instance Name, Local Core
Connectivity)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with local core connectivity and a user-provided service instance name.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet1/0/6, GigabitEthernet1/0/7.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/12, FastEthernet1/0/14.
Configlets
Comments
U-PE
N-PE
vlan 45
exit
!
interface FastEthernet1/0/12
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 45
!
interface FastEthernet1/0/14
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 45
switchport nonegotiate
no shutdown
mac access-group ISC-FastEthernet1/0/14 in
!
mac access-list extended
ISC-FastEthernet1/0/14
deny any host 0100.0ccc.cccc
deny any host 0100.0ccc.cccd
deny any host 0100.0ccd.cdd0
deny any host 0180.c200.0000
permit any any
ethernet evc service_int
!
interface GigabitEthernet1/0/6
no shutdown
service instance 5 ethernet service_int
encapsulation dot1q 56
!
interface GigabitEthernet1/0/7
no shutdown
service instance 33 ethernet service_int
encapsulation dot1q 45
!
connect Customer2_195 GigabitEthernet1/0/7
33 GigabitEthernet1/0/6 5
•
The transport type is LOCAL.
•
The user manually provided service_int as the Service Instance Name. This is pushed onto the
device, where the Service Instance IDs are 5 and 33, respectively.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-44
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (User-Provided Service Instance Name, VPLS Core Connectivity)
FlexUNI/EVC (User-Provided Service Instance Name, VPLS Core
Connectivity)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with VPLS core connectivity and user-provided service instance name.
•
Device configuration:
– The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/0.
– The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/10.
Configlets
Comments
U-PE
N-PE
!
vlan 452
exit
!
interface FastEthernet1/0/10
no ip address
switchport trunk allowed vlan add 452
!
interface FastEthernet1/0/13
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 452
switchport nonegotiate
mac access-group ISC-FastEthernet1/0/13 in
l2 vfi vpls-test manual
vpn id 300
neighbor 22.22.22.22 encapsulation mpls
!
vlan 500
!
ethernet evc ServiceInst
!
interface GigabitEtherne7/0/0
service instance 10 ethernet ServiceInst
encapsulation dot1q 400
rewrite ingress tag pop 1 symmetric
bridge-domain 500 split-horizon
!
interface vlan500
xconnect vfi vpls-test
•
The transport type is VPLS.
•
The user manually provided ServiceInst as the Service Instance Name. This is pushed onto the
device, where the Service Instance ID is 10.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-45
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Point-to-Point Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, Point-to-Point Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity with an
end-to-end circuit with multiple links. One link terminates on an ATM interface on N-PE 1, and the
other link terminates on an Ethernet interface on N-PE 2.
•
Device configuration:
– N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.370.
– N-PE 2 is a Cisco 7600 with IOS 12.2(33) SRE.
Interface(s): GigabitEthernet4/0/2.
Configlets
Comments
N-PE 1 (ATM)
N-PE 2 (Ethernet)
!
interface ATM1/0/0.370 point-to-point
no atm enable-ilmi-trap
pvc 0/370 l2transport
encapsulation aal5snap
xconnect 192.169.105.10 123 pw-class
inter-ether
!
!
ethernet evc 1-3_51
!
interface GigabitEthernet4/0/2
no ip address
no mls qos trust
service instance 103 ethernet 1-3_51
encapsulation dot1q 370
rewrite ingress tag pop 1 symmetric
xconnect 192.169.105.20 123 encapsulation
mpls
!
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-46
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Multipoint Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, Multipoint Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity with a
multipoint circuit. Link #1 terminates on an ATM interface on N-PE 1, link #2 terminates on an
Ethernet interface on N-PE 1, and link #3 terminates on an Ethernet interface on N-PE 2.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/4, ATM6/0/0.100.
– The N-PE 2 is a Cisco 7600 with IOS 12.2(33) SRE.
Interface(s): GigabitEthernet7/0/5.
Configlets
Comments
N-PE 1 (ATM + Ethernet)
N-PE 2 (Ethernet)
!
vlan 500
exit
!
ethernet evc Customer1_166
!
interface GigabitEthernet7/0/4
no shutdown
service instance 1 ethernet Customer1_166
encapsulation dot1q 600
bridge-domain 500 split-horizon
!
interface ATM6/0/0.100 point-to-point
pvc 200/300
encapsulation aal5snap
bridge-domain 500 split-horizon
!
interface Vlan500
no ip address
description UT-9
xconnect 1.1.1.1 6 pw-class
ISC-pw-tunnel-400
no shutdown
!
vlan 800
exit
!
ethernet evc Customer1_166
!
interface GigabitEthernet7/0/5
no shutdown
service instance 1 ethernet Customer1_166
encapsulation dot1q 623
bridge-domain 800 split-horizon
!
interface Vlan800
description UT-9
xconnect 192.169.105.20 6 pw-class
ISC-pw-tunnel-900
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-47
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core
Connectivity, Point-to-Point Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with local core connectivity with a
point-to-point circuit. The circuit terminates on different ATM interfaces on the same local N-PE.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/1, ATM4/1/0, ATM1/0/1.99, ATM4/1/0.98.
Configlets
N-PE 1 (ATM)
N/A
!
interface ATM1/0/1
no shutdown
!
interface ATM4/1/0
no shutdown
!
interface ATM1/0/1.99 point-to-point
pvc 99/99 l2transport
encapsulation aal0
!
interface ATM4/1/0.98 point-to-point
pvc 98/98 l2transport
encapsulation aal0
!
connect ATM-to-ATM ATM1/0/1 99/99 ATM4/1/0
98/98
!
Comments
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-48
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Multipoint Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core
Connectivity, Multipoint Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with local core connectivity for multiple
links that terminate on the same local N-PE. Link #1 terminates on an ATM interface, and link #2
terminates on an Ethernet interface.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.99, TenGigabitEthernet6/0/0, TenGigabitEthernet6/0/1.
Configlets
N-PE 1 (ATM + Ethernet)
N/A
!
vlan 1001
exit
!
interface ATM1/0/0.99 point-to-point
no atm enable-ilmi-trap
pvc 99/99
encapsulation aal5snap
bridge-domain 1001
!
!
interface TenGigabitEthernet6/0/0
no ip address
no mls qos trust
service instance 104 ethernet 1-4_60
encapsulation dot1q 11
rewrite ingress tag pop 1 symmetric
bridge-domain 1001
!
!
interface TenGigabitEthernet6/0/1
no ip address
no mls qos trust
service instance 105 ethernet 1-4_60
encapsulation dot1q 12
rewrite ingress tag pop 1 symmetric
bridge-domain 1001
!
Comments
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-49
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Multipoint Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core
Connectivity, Multipoint Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with local core connectivity. Multiple links
terminate on the same local N-PE. Link #1 terminates on an ATM interface, link #2 terminates on
an ATM interface, and link #3 terminates on an ATM interface.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM6/0/0.100, ATM6/0/1.101, ATM6/0/2.102.
Configlets
N-PE 1 (ATM)
N/A
!
vlan 500
exit
!
interface ATM6/0/0.100 point-to-point
pvc 200/300
encapsulation aal5snap
bridge-domain 500
!
interface ATM6/0/1.101 point-to-point
pvc 201/301
encapsulation aal5snap
bridge-domain 500
!
interface ATM6/0/2.102 point-to-point
pvc 202/302
encapsulation aal5snap
bridge-domain 500
!
Comments
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-50
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core
Connectivity, Point-to-Point Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with local core connectivity. A
point-to-point circuit terminates on different ATM interfaces on same local N-PE.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0, ATM1/0/1.
Configlets
N-PE 1 (ATM)
N/A
!
interface ATM1/0/0
atm pvp 33 l2transport
!
interface ATM1/0/1
atm pvp 222 l2transport
!
connect Customer1_208 ATM1/0/0 33 ATM1/0/1
222
Comments
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-51
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, End-to-End Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity for
end-to-end circuit with multiple links. One link terminates on ATM interface on N-PE 1, and other
link terminates on an Ethernet interface on N-PE 2.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.370.
– The N-PE 2 is a Cisco ASR 9000 with IOS XR 3.9.0.
Interface(s): GigabitEthernet0/0/0/4.458.
Configlets
Comments
N-PE 1 (ATM)
N-PE 2 (Ethernet)
!
interface ATM1/0/0.370 point-to-point
no atm enable-ilmi-trap
pvc 0/370 l2transport
encapsulation aal5snap
xconnect 192.169.105.10 123 pw-class
inter-ether
!
interface GigabitEthernet0/0/0/4.458
l2transport
encapsulation dot1q 458
!
l2vpn
xconnect group VPNSC
p2p iscind-crs-1--48856
interface GigabitEthernet0/0/0/4.458
neighbor 192.168.118.167 pw-id 123
!
!
!
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-52
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, Multipoint Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, Multipoint Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity with an
end-to-end circuit with multiple links. One link is terminating on an ATM interface on N-PE 1, and
the other (non-flex) link terminates on an Ethernet interface on N-PE 2.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM4/1/0.8790.
– The N-PE 2 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet4/0/17.600.
Configlets
Comments
N-PE 1 (ATM)
N-PE 2 (Ethernet)
interface ATM4/1/0.8790 point-to-point
pvc 150/3454 l2transport
encapsulation aal5snap
xconnect 192.169.105.10 760 pw-class
ISC-pw-tunnel-1
interface GigabitEthernet4/0/17.600
encapsulation dot1Q 600
xconnect 192.169.105.20 760 pw-class
ISC-pw-tunnel-1
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-53
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core Connectivity, Point-to-Point Circuit)
FlexUNI/EVC (ATM-Ethernet Interworking, Local Core
Connectivity, Point-to-Point Circuit)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with local core connectivity for
point-to-point circuit. The circuit terminates on the same, local N-PE 1. One link terminates on an
ATM interface, and the other (non-flex) link terminates on an Ethernet interface.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.444.
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): FastEthernet3/39.674.
Configlets
N-PE 1 (ATM + Ethernet)
N/A
!
interface FastEthernet3/39.674
encapsulation dot1Q 674
!
interface ATM1/0/0.444 point-to-point
pvc 44/4444 l2transport
encapsulation aal5snap
!
connect Customer1_204 ATM1/0/0 44/4444
FastEthernet3/39.674 interworking ethernet
Comments
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-54
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, with Bridge Domain)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, End-to-End Circuit, with Bridge Domain)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity for
end-to-end circuit with multiple links with bridge domain enabled. One link terminates on an ATM
interface on N-PE 1, and the other link terminates on a flex Ethernet interface on N-PE 2.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.370.
– The N-PE 2 is a Cisco ASR 9000 with IOS XR 3.9.0.
Interface(s): GigabitEthernet0/0/0/25.341.
Configlets
Comments
N-PE 1 (ATM)
N-PE 2 (Ethernet)
!
interface ATM1/0/0.370 point-to-point
no atm enable-ilmi-trap
pvc 0/370 l2transport
encapsulation aal5snap
xconnect 10.20.21.1 4531 pw-class
ISC-pw-tunnel-1
interface GigabitEthernet0/0/0/25.341
l2transport
encapsulation dot1q 341
rewrite ingress tag push dot1q 430
second-dot1q 349 symmetric
!
l2vpn
bridge group tml
bridge-domain CISCO
interface GigabitEthernet0/0/0/25.341
!
neighbor 192.169.105.20 pw-id 32190
!
!
!
!
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-55
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, with Bridge Domain)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, End-to-End Circuit, with Bridge Domain)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity for
end-to-end circuit with multiple links. Bridge domain is enabled. One link terminates on an ATM
interface on N-PE 1, and the other (non-flex) link terminates on an Ethernet interface on N-PE 2.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.370.
– The N-PE 2 is a Cisco ASR 9000 with IOS XR 3.9.0.
Interface(s): GigabitEthernet0/0/0/20.712.
Configlets
Comments
N-PE 1 (ATM)
N-PE 2 (Ethernet)
!
interface ATM1/0/0.370 point-to-point
no atm enable-ilmi-trap
pvc 0/370 l2transport
encapsulation aal5snap
xconnect 10.20.21.1 4531 pw-class
ISC-pw-tunnel-1
!
interface GigabitEthernet0/0/0/20.712
l2transport
encapsulation dot1q 712
!
l2vpn
bridge group tml
bridge-domain CISCO
interface GigabitEthernet0/0/0/20.712
!
neighbor 192.169.105.20 pw-id 1005
!
!
!
!
•
None.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-56
OL-21636-01
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, no Bridge Domain)
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core
Connectivity, End-to-End Circuit, no Bridge Domain)
Configuration
•
FlexUNI(EVC)/ATM-Ethernet Interworking.
•
Feature: FlexUNI/EVC for ATM-Ethernet interworking with pseudowire core connectivity for
end-to-end circuit with multiple links. Bridge domain is disabled. One link is terminates on an ATM
interface on N-PE 1, and the other link terminates on an Ethernet interface on N-PE 2.
•
Device configuration:
– The N-PE 1 is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): ATM1/0/0.370.
– The N-PE 2 is a Cisco ASR 9000 with IOS XR 3.9.0.
Interface(s): GigabitEthernet0/0/0/12.433.
Configlets
Comments
N-PE 1 (ATM)
N-PE 2 (Ethernet)
!
interface ATM1/0/0.370 point-to-point
no atm enable-ilmi-trap
pvc 0/370 l2transport
encapsulation aal5snap
xconnect 10.20.21.1 4531 pw-class
ISC-pw-tunnel-1 !
interface GigabitEthernet0/0/0/12.433
l2transport
encapsulation dot1q 433
rewrite ingress tag push dot1q 43
second-dot1q 53 symmetric
!
l2vpn
xconnect group ISC
p2p CISCO
interface GigabitEthernet0/0/0/12.433
neighbor 192.169.105.20 pw-id 4531
!
!
!
!
•
None.
•
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
A-57
Appendix A
Sample Configlets
FlexUNI/EVC (ATM-Ethernet Interworking, Pseudowire Core Connectivity, End-to-End Circuit, no Bridge Domain)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
A-58
OL-21636-01
A P P E N D I X
B
Working with Templates and Data Files
This appendix describes how to use templates and data files with ISC policies and service requests. It
contains the following sections:
Note
•
Overview, page B-1
•
Using Templates with ISC Policies, page B-4
•
Using Templates with Service Requests, page B-10
For an overview of the Template Manager and how templates and data files are created in ISC, see
Chapter 6, “Service Design” and Appendix D, “Template Usage” in the Cisco IP Solution Center
Infrastructure Reference, 6.0.
Overview
ISC’s Template Manager allows you to create, manage, and store templates and associated data files. The
purpose of using templates is to provide a means to download free-form CLIs to a device, in order to
deploy commands and configurations not normally supported by ISC. Templates are written in the
Velocity Template Language and are generally comprised of IOS (and IOS XR) device CLI
configurations. Optionally, you can set variables (also defined in Velocity) that are substituted with data
stored in data files. The template and data file information is downloaded to the device at the time of
service activation. The information in this appendix assumes the templates (including subtemplates, if
applicable) and (optional) data files have been set up.
Note
You can also create data files “on demand” during service request creation, as covered in later sections
of this appendix.
This overview section covers the following topics:
•
Summary of Template Manager Features, page B-1
•
Template and Data File Workflow, page B-3
Summary of Template Manager Features
This section highlights key features of template and data file support in ISC, especially those that have
an impact on working with policies and service requests.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-1
Appendix B
Working with Templates and Data Files
Overview
Template Attributes
The ISC template mechanism allows you to differentiate templates by specifying (optional) attributes on
a template, including:
•
Device type
•
Line card type
•
Port type
•
Software version (IOS or IOS XR)
These attributes are set through a drop-down list when setting up the template in Template Manager. ISC
uses these attributes to automatically select the template/data file that most closely matches the device
defined within the service request. See the section Using Templates with Service Requests, page B-10,
for additional information.
Associating Templates at the Policy Level
ISC supports the association of templates and data files in policies.
Selective Determination of Templates for U-PE and PE-AGG Device Roles
For added flexibility, ISC allows you to selectively apply templates to U-PE and PE-AGG devices (for
example, in a ring environment) based on whether the devices have a UNI interface.
Enhanced Subtemplate Support
A new attribute in the Template Editor allows subtemplates to be associated with a template. ISC
supports dynamic instantiation of subtemplates based on device attributes. While creating the
subtemplates, values for these identifiers must be provided by the operator.
Dynamic Data File Creation
The user can create a data file during service request creation and associate it to the template copied from
the associated policy. This functionality extends data file creation from the Template wizard to doing so
directly from the service request wizard Template Association screen. In addition, you can modify any
or all variables that are part of the template/date file attached to a service request and apply the updated
template/data file without removing the entire service.
Automatic Application of Negate Templates
To remove a configuration created from a template/data file, a negate template must be applied to the
existing service. This is no longer a manual process in ISC. You create both the positive and negate
template. You can assign a positive template/data file to a policy. ISC calls the appropriate negate
template at the appropriate time, as the negate template has a direct relationship with the deploy
template. ISC determines which negate template to use, based on the service request action requested
(for example, deploying or decommissioning a service). The negate template has the same name as the
template, with the addition of the suffix .Negate. The negate template does not share the data file of the
deploy template. The negate template must have its own data file defined.
Compatibility of the Template Mechanism with Previous ISC Releases
ISC maintains compatibility with the template mechanism in previous ISC releases. Templates created
in earlier versions of ISC work “as is,” without any modifications to the templates or the workflow. In
the case of a policy in the system that was created in an earlier ISC release, the GUI workflow for
associating templates/data files is not visible. In such a case, the operator adds the template and data files
during service deployment, as in previous releases of ISC.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-2
OL-21636-01
Appendix B
Working with Templates and Data Files
Overview
Template Support for IOS and IOS XR
The template mechanism is supported for both IOS and IOS XR devices. For IOS XR devices, the
configlet generated from templates/data files contains CLI commands and not XML statements. For
IOS XR devices, template support is provided as CLI commands. For IOS devices, the operator can
download a template configlet using the device console.
Note
Note the following known issue in the case of IOS XR devices. When a service request is deployed with
templates that contain improper or unsupported configurations, the service request still goes to the
DEPLOYED state. This because the IOS XR device does not issue an error report on the improper
configuration(s) deployed.
RBAC Support for Template Usage
Templates and data files are only accessible to users with the proper RBAC role. A permission type for
data files has been added. The permissions allowed for the data files are view, create, modify, and delete.
Operators cannot view templates/data files assigned to other roles, and are not permitted to deploy
templates/data files to which they do not have access. See the Cisco IP Solution Center Infrastructure
Reference, 6.0 for more information on RBAC support for templates/data files.
Template Variables
Template variables support most ISC repository variables for MPLS, L2VPN, VPLS, and FlexUNI/EVC.
For a list of supported template variables, see the “Devices” chapter of the Cisco IP Solution Center
Infrastructure Reference, 6.0.
DCPL Properties
There are a few Dynamic Component Properties Library (DCPL) properties governing templates. These
DCPL properties affect when a template is applied, whether negate templates are appended or
prepended, whether templates are applied in the case when an service has multiple lines, only one of
which have been edited, etc. For documentation on DPLC properties related to templates, see the
“Properties” chapter of the Cisco IP Solution Center Infrastructure Reference, 6.0.
Importing and Exporting Templates
ISC provides a mechanism to import and export templates and data files. See the Cisco IP Solution
Center Infrastructure Reference, 6.0 for more information.
Template and Data File Workflow
This section summarizes the basic operations involved in setting up and using templates, data files, and
negate templates in ISC.
Basic Template Manager Functions
•
Create templates and negate templates for different configurations.
•
Specify device attributes for the templates.
•
Associate subtemplates to templates, if applicable
•
Create data files for the subtemplates.
•
Create a negate template for each subtemplate.
•
Create data files for the negate templates.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-3
Appendix B
Working with Templates and Data Files
Using Templates with ISC Policies
•
Create a super template and attach subtemplates to it.
These basic Template Manager functions are documented in the Cisco IP Solution Center Infrastructure
Reference, 6.0. See that guide for more information on these tasks.
Policy-Level Template Functions
•
Create a policy and enable template support for the policy.
•
Associate templates and (optionally) data files to the policy, if desired.
For information on how to associate templates and data files at the policy level, see the section Using
Templates with ISC Policies, page B-4, in this appendix.
Service Request-Level Template Functions
Note
When a policy is only associated with a template and no data file, then during creation of a service
request using that policy, automatic selection of a data file for that template takes place, if the template
has only one data file. If the template does not have a data file, then one must be created for that template
and associated to the service request before saving is permitted.
•
Create a service request and associate template(s) to a link.
•
Deploy the service request on a device (for example, a 7600).
•
The subtemplate and corresponding data file for the 7600 are autoselected for deployment.
•
A configlet is generated from the subtemplate.
•
Decommission the service request.
•
The negate template for the subtemplate is autoselected and deployed.
For information on how to use templates and data files is service requests, see the section Using
Templates and Data Files with Service Requests, page B-14, in this appendix.
Using Templates with ISC Policies
This section provides information on how to enable template support and associate templates/data files
with ISC policies. It contains the following sections:
•
Overview of Template Support in ISC Policies, page B-4
•
Associating Templates and Data Files to a Policy, page B-5
Overview of Template Support in ISC Policies
ISC supports associating templates/data files to a service policy. This minimizes steps in the
provisioning workflow and also reduces potential errors that can occur if an incorrect template/data file
is selected during service creation. In the Policy Editor workflow, after the policy attributes are set, a
new Templates Association window appears. The Enable Templates check box that appears in this
window allows you to enable template association for the policy and to specify templates/data files to be
available for service requests based on the policy. More than one template/data file can be associated to
the policy. Each template/data file can be associated to a device role. The available device roles are
determined by the policy type. In the case of U-PE and PE-AGG device roles, templates/data files can
be selectively determined based on whether the device has a UNI interface. Later, at the time of service
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-4
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with ISC Policies
request creation, templates are only available if the device type matches the role type specified for the
template within the policy or role type along with (or without) the presence of UNI interface in the
policy.
Associating Templates and Data Files to a Policy
This section describes how to associate templates and data files to an ISC policy. These features also
apply in the case of editing a policy.
After the policy attributes are set for a policy, the Template Association window appears in the workflow,
as shown in Figure B-1.
Figure B-1
Template Association Window
This window is where you associate the templates/data files as a final step before clicking the Finish
button and saving the policy settings.
Perform the following steps to associate template(s)/data file(s) with the policy.
Step 1
Check the Template Enable check box to enable template use in service requests based on this policy.
This check box is unchecked by default.
The GUI updates with fields allowing you to associate templates/data files to the policy, as shown in
Figure B-2.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-5
Appendix B
Working with Templates and Data Files
Using Templates with ISC Policies
Figure B-2
Step 2
Template Association Window with Template Enable Checked
Click the Add button to add a row in which to specify associated templates/data files.
A new row appears in the GUI, providing fields to set the role type, specify templates/data files, and
specify if the template/data file is editable within service requests based on the policy.
Step 3
In the Role Type column, choose a device role from the drop-down list.
The role selections might include:
Note
Step 4
•
N-PE
•
PE-AGG
•
U-PE
•
CE (MULTI_VRF)
•
CE (MANAGED)
•
MVRF
The available device roles in the drop-down list are determined by the policy type.
To add a template/data file click the Add link in the Template/Data File column.
The Add/Remove Templates window appears, as shown in Figure B-3.
Figure B-3
Add/Remove Template Pop-Up
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-6
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with ISC Policies
Step 5
Note
Click the Add button to select a template/data file to associate with the policy.
If the device role is specified as U-PE or PE-AGG, templates can be selectively added based on whether
the device has a UNI interface. For details on this feature, see Selectively Determining Templates for
U-PE and PE-AGG Device Roles, page B-9. The actual steps for adding templates/data files are the same
as in the following steps.
The Template Datafile Chooser window appears, as shown in Figure B-4.
Figure B-4
Template Datafile Chooser Window
This is a standard Template Manager window used to navigate to and choose templates and (optionally)
data files in ISC.
Note
Step 6
The following steps involving the Template Datafile Chooser window assume a familiarity with the
functionality of the window. For additional information about Template Manager and how templates and
data files are created and managed in ISC, see the Cisco IP Solution Center Infrastructure Reference,
6.0. The steps shown here are for example purposes. You must modify the steps as required for your
environment. For example, you might want to choose only a template file or both a template file and a
data file to associate with the policy. Both scenarios are supported.
Navigate to a template in the folder tree and click it to select it.
The template is listed in the right side of the GUI, along with any data files that are associated with it,
as shown in Figure B-5.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-7
Appendix B
Working with Templates and Data Files
Using Templates with ISC Policies
Figure B-5
Step 7
Note
Template Datafile Chooser Window with Template and Data File Listed
Check the check box to the left of a data file name and click the Accept button.
You can select only the template or both template and data file at this stage, depending on your needs,
and whether or not a data file exists for the template.
The Template Datafile Chooser window closes and the selected template/data file appears listed in the
Add/Remove Templates window, as show in Figure B-6.
Figure B-6
Add/Remove Templates Window with Template Listed
If you did not choose a data file, then the Datafile column is blank.
Step 8
Check the check box to the left of the template name to choose the template.
Step 9
Under Action, use the drop-down list and choose APPEND or PREPEND.
Append tells ISC to append the template-generated CLIs to the regular ISC (non-template) CLIs
(configlet). Prepend is the reverse (adds the template to the beginning of the configlet).
Step 10
Choose Active to use this template for service requests based on this policy.
If you do not choose Active, the template is not used.
Step 11
To associate additional templates/data files with the policy click Add in the Add/Remove Templates
window and repeat the appropriate steps to add other templates/data files.
Step 12
To remove a template row from the window, check a template and click the Remove button to remove
the template from the list.
Step 13
When you are satisfied with the selections in the Add/Remove Templates window, click OK.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-8
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with ISC Policies
The Template Association window appears with the template(s)/data file(s) listed as active link(s). If you
have added more than one template/data file, they appear in a comma-separated list of links.
You can click on any link to return to the Add/Remove Templates window, in order to edit/update the
template/data file information.
Step 14
Check the Edit check box to make the template/data file attributes editable in service requests based on
the policy.
Step 15
To add additional templates/data files for a given role to the policy, you can click the Add button in the
Template Association window and repeat the steps outlined above.
Step 16
To delete templates/data files that have been associated to the policy, check a template/data file to choose
it.
Then click the Delete button to delete it from the Template Association window.
Step 17
When you are finished associating the template(s)/data file(s) to the policy, click the Finish button in the
Template Association window.
The attributes for the policy are saved and the policy creation or modification is complete.
Selectively Determining Templates for U-PE and PE-AGG Device Roles
ISC provides the capability to selectively determine which U-PE and PE-AGG devices (for example, in
a ring environment) to apply templates/data files. During template association in the service policy
workflow, the U-PE and PE-AGG device roles have two options to associate templates/data files. These
options are:
•
Devices with UNI. This option causes templates/data files to be configured on devices of the
specified role with a UNI interface.
•
All other devices. This option causes templates/data files to be configured on all devices of the
specified role, including those with a UNI interface.
Figure B-7 shows these options in the Template/Data File column of the Template Association window.
Figure B-7
Options for Selectively Determining Templates for U-PE and PE-AGG Device Roles
Usage notes:
•
The templates/data files are selected by clicking on the Add link next to the desired option. The
subsequent steps are the same as provided in Associating Templates and Data Files to a Policy,
page B-5.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-9
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
•
This features is not applicable for device roles other than U-PE and PE-AGG. In Figure B-7 the
N-PE role only displays a single Add link in the Template/Data File column.
•
For backward compatibility, when editing or viewing old and existing policies, for U-PE and
PE-AGG devices, associated templates/data files will display under the All other Devices option.
•
When you copy an existing policy, you can copy associated templates/data files (if any) from the All
other Devices or Devices with UNI options of the existing policy into the new policy. This is similar
to normal ISC behavior.
•
You can associate templates (without data files) for either the All other Devices or Devices with UNI
options or both.
•
Selective determination of templates is supported in all L2VPN and FlexUNI/EVC policy types and
service requests. For MPLS VPN, only MPLS PE-CE and MPLS PE-NoCE policies and service
requests are supported. For the MPLS VPN PE-CE policy type, this feature is applicable if the PE
is or is not associated with an NPC.This feature is not available for Multi-VRFCE policies and
service requests.
The following notes describe how this feature is supported in the service request workflow:
•
During service request creation, selective templates are differentiated based on the devices having a
UNI interface or having both UNI and NNI interfaces for the U-PE and PE-AGG device roles.
Templates in the policy are copied to the respective devices functioning in the specified roles. There
is no behavioral change for devices of other roles.
•
The selective determination of templates is not applicable for service request modification
scenarios, as after the service request is created, it is the user’s decision to make any changes for
templates configured on devices.
Using Templates with Service Requests
This section provides information on templates and data files with a service request. It contains the
following sections:
•
Overview of Template Use in Service Requests, page B-10
•
Using Templates and Data Files with Service Requests, page B-14
Overview of Template Use in Service Requests
This section provides overview information about template usage in service requests. It covers the
following topics:
•
Associating Templates to a Service Request, page B-11
•
Associating Subtemplates During Service Provisioning, page B-11
•
Creating Data Files During Service Request Creation, page B-12
•
Using Negate Templates to Decommission Template Configurations, page B-13
•
Using Templates and Data Files with Service Requests, page B-14
For details on how these features are implemented in the ISC GUI, see the section Using Templates and
Data Files with Service Requests, page B-14.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-10
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
Associating Templates to a Service Request
The template mechanism in ISC provides a way to add additional configuration information to a device
configuration generated by a service request. To use the template mechanism, the policy on which the
service request is based must have been set to enable templates. Optionally, templates and data files to
be used by the service request can be specified in the policy. During service request creation,
templates/data files can be added to a device configuration if the operator has the appropriate RBAC
permission to do so. See the section Choosing a Template in the Service Request Workflow, page B-14
for how to choose templates/data files in the service request workflow.
Associating Subtemplates During Service Provisioning
All templates can be used by other templates as building blocks. The template using other templates is
called a super template. The template being used is called a subtemplate. A new attribute in the Template
Editor allows subtemplates to be associated with a super template. The super template instantiates all
required subtemplates by passing values for the variables in the subtemplate. After instantiation, the
super template puts the configlets generated for the subtemplate into the super template. ISC branches
templates into subtemplates based on device type, line card type, port type, role type, and software
versions. These optional attributes are set while creating the subtemplates. The subtemplates are selected
based on the following matching criteria:
•
Only exact matches are recognized for the card type and port type attributes. No wild card match is
allowed for these attributes.
•
Only an exact match is recognized for the device type attribute.
•
For the software version attribute, the match is done for a software version equal to the current
version, if available. If not, the previous highest version is matched.
•
If exact matching attributes are not found, then the match proceeds with the criteria described in
Table B-1. An information message listing the exactly matched subtemplates of the super-template
is shown if and only if any of the matching criteria are met.
•
If none of the attributes are matched, then the default subtemplate is applied.
•
If no default subtemplate exists, a subtemplate with all null attribute values is matched.
•
If none of the rows specified in the table match, then ISC looks for subtemplates that are marked as
device default, or else version default. If no subtemplates are marked as such, then no matching
subtemplates are picked. A warning message is displayed.
The matching criteria are summarized in Table B-1.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-11
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
Table B-1
Default SubTemplate Matching Criteria
Matching
Order
Role Type
Device Type
Line Card
Port Type
Software Version
1
Exact Match
Exact Match
Exact Match
Exact Match
Exact Match
2
Exact Match
Exact Match
Exact Match
Exact Match
Previous Highest
3
Exact Match
Exact Match
Exact Match
No Values
Exact Match
4
Exact Match
Exact Match
Exact Match
No Values
Previous Highest
5
Exact Match
Exact Match
No Values
No Values
Exact Match
6
Exact Match
Exact Match
No Values
No Values
Previous Highest
7
Exact Match
Exact Match
No Values
No Values
No Values
8
Exact Match
No Values
Exact Match
Exact Match
Exact Match
9
Exact Match
No Values
Exact Match
Exact Match
Previous Highest
10
Exact Match
No Values
Exact Match
No Values
Exact Match
11
Exact Match
No Values
Exact Match
No Values
Previous Highest
12
Exact Match
No Values
No Values
No Values
Exact Match
13
Exact Match
No Values
No Values
No Values
Previous Highest
14
Exact Match
Default
No Values
No Values
No Values
15
Exact Match
No Values
No Values
No Values
Default
16
Exact Match
No Values
No Values
No Values
No Values
Additional usage notes for subtemplates:
•
ISC does not perform checks for the depth of subtemplates. Only one level of subtemplates is
supported.
•
No validations are done to check if the super template and subtemplate structures are cyclic.
•
When the operator attempts to delete a subtemplate that is referenced by a super template, a warning
message is generated.
•
Subtemplates can be modified.
•
Subtemplates can be attached to multiple super templates.
•
In the current release, multiple data files are not supported for subtemplates. If multiple data files
are found, the service request automatically chooses the first data file (from a list of available data
files, sorted alphabetically).
Creating Data Files During Service Request Creation
The operator can create data files “on demand” during service request creation. If template(s) are
attached to a service policy, and no data file(s) exist for the template(s), a wizard prompts the operator
to enter values for variables. If data file(s) are created on demand during service request creation, it is
possible to modify any or all of the variables during modification or redeployment of the service request.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-12
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
The service request workflow supports dynamic creation of data files as follows:
•
If a template is marked as non-editable in the policy on which the service request is based, the
operator cannot edit it during service request creation. However, the name of template and data files
are still visible, even though they cannot be modified.
•
If a template is marked as editable in the policy, then (assuming appropriate RBAC permission) the
operator can change the template/data files during service request creation.
The following points apply if the template is editable:
•
If a template is associated with a service policy, and at least one data file exists for the template, the
operator can select the appropriate data file during service request creation.
•
If only one data file exists for the template, it is automatically selected.
•
During service request creation, the operator can enter values for template variables.
•
Optionally, if no data file exists for the template, the operator can create a new data file during
service request creation. When the Datafile Chooser window is opened from Template Association
window, a Create Datafile button is provided, which allows the new data file to be created.
•
The Create Datafile button is only displayed if the operator has the appropriate RBAC permissions
to create a data file.
•
See the section Creating a Data File in the Service Request Workflow, page B-16 for how to set up a data
file in the service request workflow.
Using Negate Templates to Decommission Template Configurations
To remove a configuration created from a template/data file, a negate template must be applied to the
existing service. ISC automatically applies the appropriate negate template during the decommission of
the service request. For instructions on how to use the ISC Template Manager to create negate templates,
see the Cisco IP Solution Center Infrastructure Reference, 6.0.
When a template is associated in a policy or service request, the negate template automatically gets
associated. During decommission of the service, the negate template is used for deployment. When
decommissioning a service request associated with a template/data file, the negate template is
automatically picked up dynamically, by searching for a template name having the name of the original
template followed by a suffix .Negate. This takes place at deployment time. Negate templates are
dynamically instantiated based on the device attributes of the template to which it is associated.
Note
Optional attributes (such as device type, line card type, port type, and software version) applied to a
template automatically apply to the corresponding negate template. The optional attributes cannot be
applied directly to negate templates.
When a service is decommissioned, the appropriate negate template is deployed. The data file for a
negate template is selected during deployment as follows:
•
If only one data file is associated with the negate template, the data file is automatically selected.
•
If multiple data files are found, the data file with same name as template is selected.
•
If multiple data files are found but no data file with the same name exists, the template is skipped.
•
If no data file is found, the template is skipped.
The following points cover the behavior of templates in various modification scenarios:
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-13
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
•
If you change the template associated with a service request, the negate template automatically
changes to the negate template of the newly selected template. In this case, ISC executes the negate
template of the previously associated template, as well as the newly associated template.
•
When a template or negate template is modified, the service request does not roll back the
configuration changes made earlier through the template.
•
When a service request is modified, the template command is always deployed. (See the remaining
bullet items for some additional clarifications.)
•
When a service request is modified without changing template/data file information, the template
commands are not redeployed. The only a modification that triggers a change in template/data file
results is the negation of the old template and the addition of new template commands in the device
configlet.
•
When the ForceTemplateDeploy DCPL property is turned ON then, irrespective of templates being
modified, if a service request is modified, templates are re-deployed. However, negate templates are
not necessarily re-deployed. Negate templates are deployed only when a link/attachment circuit in
the service request is deleted, which implicitly means removing templates associated with the link
being deleted as well. When the ForceTemplateDeploy DCPL property is turned OFF, negate
templates are instantiated under the following conditions:
– Deleting or decommissioning a link/attachment circuit in a service request.
– Modifying templates (for example, delete existing templates and adding new ones to a link, or
deleting only existing ones).
– Rehoming links/devices in a service request that has associated templates.
•
When a device is changed in a service request, the negate template is deployed for the old device,
and the template is deployed for the new device.
•
When a link in a service request is removed and a new link is added, a negate template is deployed
for the deleted link and a template is deployed for the added link.
Using Templates and Data Files with Service Requests
This section describes tasks related to templates, data files, and negate templates that can be performed
in the service request workflow. The following tasks are covered:
•
Choosing a Template in the Service Request Workflow, page B-14
•
Creating a Data File in the Service Request Workflow, page B-16
•
Decommissioning Service Requests with Added Templates, page B-18
•
Viewing Templates from the Service Requests Window, page B-18
Choosing a Template in the Service Request Workflow
When creating a service request, the workflow involves selecting a policy on which to base the service
request, setting interface and other attributes, and so on. The specific windows and attributes presented
in the workflow depend on the type of service request, such as L2VPN, VPLS, MPLS, or FlexUNI/EVC.
To associate templates and data files in a service request, you must select a link in the appropriate
window of the Service Request Editor window, usually by clicking the Add link for the device.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-14
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
Note
There is no choice of options to selectively determine templates for U-PE and PE-AGG devices during
the service request workflow. Templates are automatically copied from the policy, based on the presence
of a UNI interface on the devices functioning in U-PE and PE-AGG roles. See the section Selectively
Determining Templates for U-PE and PE-AGG Device Roles, page B-9, for more information on this
feature.
Perform the following steps to choose the template(s)/data file(s) for the device(s):
Step 1
Click the Add link in Template/Datafile column for a device.
The Add/Remove Templates window appears.
Step 2
Click the Add button.
The Template Datafile Chooser window appears.
Step 3
Navigate to a template in the folder tree and select it.
The template is listed in the right side of the GUI, along with any data files that are associated with it.
At this point, you can either select an existing data file, or click the Create Data File button to create a
data file dynamically in the workflow. The rest of the steps in this section cover the case of selecting an
existing template and data file. For instructions on how to create a data file dynamically, see the section
Creating a Data File in the Service Request Workflow, page B-16.
Step 4
Check the check box of a data file to choose it.
Step 5
Click the Accept button to confirm the choice.
The template/data file combination appears in the Add/Remove Templates window.
Step 6
To add additional templates/data files to the list, click the Add button and repeat the appropriate steps,
as covered above.
Step 7
When you are satisfied with selection of templates/data files, click the OK button in the Add/Remove
Templates window.
The templates/data files appear in the Template/Datafile column of the Template Association window,
as shown Figure B-8.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-15
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
Figure B-8
Sample Templates Association Window with Templates/Data Files Selected
If multiple templates/data files are selected for a device, they appear as a comma-separated list, as shown
in the figure.
Step 8
Click the Finish button to create the service request with the template/data file selections you chose.
If the template associated to the service request is a super template comprising of one or more
subtemplates, ISC displays a message confirming this.
For information about how templates/data files are instantiated when the service is deployed, see the
information provided in the section Associating Templates to a Service Request, page B-11.
Creating a Data File in the Service Request Workflow
During the final stage of setting the link attributes for a service request, the Template Association
window appears, such as the one shown in Figure B-8. The Template Association window lists the
devices comprising the link, the device roles, and the template(s)/data file(s) associated with the devices.
You can choose the template(s)/data file(s) to be associated with the devices, as described in the section
Choosing a Template in the Service Request Workflow, page B-14. If one of the templates selected in
the Template Datafile Chooser window does not have an associated data file or if you would like create
a new data file for it, you can do this dynamically in the workflow while setting up the service request.
Perform the following steps to dynamically set up a new data file for a template:
Step 1
In the Template Association window, click the Add link in the Template/Datafile column for a device.
(If a template was previously selected for a device, click the link for the template name.)
The Add/Remove Templates window appears.
Step 2
Click the Add button.
The Template Datafile Chooser window appears.
Step 3
Navigate to a template in the folder tree and select it.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-16
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
The template is listed in the right side of the GUI, along with any data files that are associated with it.
This example uses the AccessList1 template in the Examples directory, as shown in Figure B-9.
Figure B-9
Step 4
Templates Datafile Chooser Window with No Data File Listed
Click the Create Data File button to create a data file dynamically in the workflow.
The Data File Editor window appears, as shown in Figure B-10.
Figure B-10
Step 5
Data File Editor Window
At this point, you are in the standard workflow for creating a data file in ISC.
In the Date File Editor window, you can specify a name and description for the data file, set variable
values, view the configlet, and so on. For details on how to perform these steps, see the chapter “Service
Design” in the Cisco IP Solution Center Infrastructure Reference, 6.0.
Step 6
When you have completed setting the attributes for the new data file, click Save and then Close to save
this information and close the file; click Configure to show the configuration file; or click Close and
then be sure to click OK, if you want to save the information you have created.
If you do not want to save this information, click Close and then click Cancel.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-17
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
When the data file is saved, the Template Datafile Chooser window appears with the newly created data
file listed.
Decommissioning Service Requests with Added Templates
This section describes how to decommission ISC service requests that have added templates.
Note
For general information on how templates are used in ISC, see Chapter 6, “Service Design” and
Appendix D, “Template Usage” in the Cisco IP Solution Center Infrastructure Reference, 6.0.
As mentioned in the Cisco IP Solution Center Infrastructure Reference, 6.0, “Template commands are
treated independently from those associated with a service creation. Consequently, template commands
must be removed separately from the device(s) during a service decommission. To remove prior template
commands, a separate template is needed during a decommission process. Decommissioning a service
request does not automatically remove the original template commands. A separate negate template
needs to be added to the decommission process and the original templates must be removed. The negate
template must contain the necessary NO commands to successfully remove any unwanted IOS
commands added by the original template.”
The standard way to create a service request with a template added is as follows:
1.
Define the service policy.
2.
Build a template with a data file (and also a negate template and data file).
3.
Create the service request with the template added. The steps to do this are covered in relevant
chapters of this guide.
4.
Deploy the service request to which the template was added.
To decommission a deployed service request, including associated templates, you must perform the
following steps.
1.
Create a negate template with data file (if one does not exist). This is used to remove the commands
imposed by the original template. For an explanation of negate templates, see Chapter 4, “Using
Templates” in the Cisco IP Solution Center API Programmer Guide, 6.0.
2.
Decommission the service request. The negate template will be picked up dynamically.
The service request remains in the Requested state, but changed to an Operation Type of Delete.
3.
Deploy the service request. This decommissions the service request and downloads the negate
template, which removes the original template commands.
Viewing Templates from the Service Requests Window
In the Service Requests window, a paper clip icon appears in the Data Files column if a service request
has one or more templates associated with it, as shown in Figure B-11.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-18
OL-21636-01
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
Figure B-11
Note
Service Requests Window with Data Files Column
You can use the Show Services with field to search for service requests that have a specific data or
template file. Choose Data File Name or Template Name from the drop-down list and enter a search
string in the matching field. The matching field is not case-sensitive and supports wildcards (*). You
can further limit the search by using the of Type field to confine the search to a particular service type.
When listing service requests using Template Name, provide the entire path of the template file location
(for example: examples\template, where examples is the folder name and template implies the template
name).
To view the configlet(s) for the template(s) associated with a service request, perform the following
steps.
Step 1
In the Service Requests window, check the check box for a service request with an associated template,
as indicated by a paper clip icon in the Data Files column.
Step 2
Click the Details button.
The Service Request Details window appears, as shown in Figure B-12.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
B-19
Appendix B
Working with Templates and Data Files
Using Templates with Service Requests
Figure B-12
Service Request Details Window
The Associated data file(s) row displays a link for each data file associated with the service request, as
shown in the figure.
Step 3
Click a data file link to display the configlet for the template.
Step 4
After viewing the configlet, click OK to close the configlet display window.
Step 5
Click OK to close the Service Request Details window.
Step 6
As an alternative, you can access the data files associated with a service request by clicking on the paper
clip icon in the Service Requests window.
The Service Request Datafile Details window appears, as shown in Figure B-13.
Figure B-13
Service Request Datafile Details Window
The window displays only a list of the data files associated with the service request.
Step 7
Click a data file link to display the configlet for the template.
Step 8
After viewing the configlet, click OK to close the configlet display window.
Step 9
Click Close to close the Service Request Datafile Details window and return to the Service Requests
window.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
B-20
OL-21636-01
A P P E N D I X
C
Setting Up VLAN Translation
This appendix describes how to set up VLAN translation for L2VPN ERS (EVPL) services. It contains
the following sections:
Note
•
VLAN Translation Overview, page C-1
•
Setting Up VLAN Translation, page C-1
•
Platform-Specific Usage Notes, page C-6
For helpful information to be aware of before you create policies and services using VLAN translation,
review Platform-Specific Usage Notes, page C-6.
VLAN Translation Overview
VLAN translation provides flexibility in managing VLANs and Metro Ethernet-related services. There
are two types of VLAN translation—one is 1-to-1 translation (1:1), and the other one is 2-to-1 translation
(2:1). This feature is available for L2VPN ERS (EVPL) (with and without a CE). The behavior of
L2VPN ERS (EVPL) service remains the same, even though it is true that it is possible now for one
Q-in-Q port to be shared by both EWS (EPL) and ERS (EVPL) service. VLAN translation is only for an
Ethernet interface, not for other types of interfaces, such as ATM and Frame Relay.
With 1:1 VLAN translation, the VLAN of the incoming traffic (CE VLAN) is replaced by another VLAN
(PE VLAN). It means the service provider is now able to handle the situation where incoming traffic
from two different customers share the same CE VLAN. The SP can map these two CE VLANs to two
different PE VLANs, and customer traffic will not be mixed.
With 2:1 VLAN translation, the double tagged (Q-in-Q) traffic at the U-PE UNI port can be mapped to
different flows to achieve service multiplexing. The translation is based on the combination of the CE
VLAN (inner tag) and the PE VLAN (outer tag). Without this translation, all the traffic from a Q-in-Q
port can only go to one place because it is switched only by the outer tag.
Setting Up VLAN Translation
The following sections described how to create and manage policies and service requests to support
VLAN translation:
•
Creating a Policy, page C-2
•
Creating a Service Request, page C-3
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
C-1
Appendix C
Setting Up VLAN Translation
Setting Up VLAN Translation
•
Modifying a Service Request, page C-5
•
Deleting a Service Request, page C-5
Creating a Policy
VLAN translation is specified during policy creation for L2VPN for ERS (EVPL) (with and without a
CE). The L2VPN (Point to Point) Editor window contains a new option called VLAN Translation. (See
Figure C-1.)
Figure C-1
VLAN Translation Option in the L2VPN (Point to Point) Editor Window
There are three options for VLAN translation:
•
No—This is the default choice. No VLAN translation is performed.
Note
If you choose No and you do not want to deal with any behavior related to VLAN translation
during service request creation, then uncheck the Editable check box. This is the
recommendation when you choose no VLAN translation.
•
1:1—1:1 VLAN translation. The VLAN of the incoming traffic (CE VLAN) is replaced by another
VLAN (PE VLAN). The specification of the VLAN translation is done during the creation of the
service request for the policy, as covered in Creating a Service Request, page C-3.
•
2:1—2:1 VLAN translation. The double tagged (Q-in-Q) traffic at the U-PE UNI port can be
mapped to different flows to achieve service multiplexing. When you choose 2:1 VLAN translation,
the L2VPN (Point to Point) Editor window dynamically changes to enable you to choose where the
2:1 VLAN translation takes place. (See Figure C-2.)
Figure C-2
Choose Where 2:1 VLAN Translation Takes Place
The choices for where 2:1 VLAN translation takes place are:
•
Auto (This is the default choice.)
•
U-PE
•
PE-AGG
•
N-PE
If you choose Auto, the 2:1 VLAN translation takes place at the device closest to the UNI port. The other
choices come into play only when there is more than one place that 2:1 VLAN translation can be done.
If there is only one place where the translation can be done, the choice is ignored.
The actual VLAN values are specified when you create a service request based on this policy. See
Creating a Service Request, page C-3.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
C-2
OL-21636-01
Appendix C
Setting Up VLAN Translation
Setting Up VLAN Translation
Creating a Service Request
When you create a service request based on an L2VPN ERS (EVPL) policy, the VLAN options can be
changed if they were set to be editable in the policy. You can overwrite the policy information for the
VLAN translation type and the place where translation occurs. This flexibility allows the following
provisioning:
•
One AC can have 2:1 VLAN translation, while the other AC can have no VLAN translation or 1:1
VLAN translation.
•
The VLAN translation for one AC can be on the UNI box, while the translation for the other AC can
be on the PE-AGG.
Note these modifications can happen only when a new service request is created. They are not
allowed during the modification of an existing service request.
Note
The specification of the VLAN translation happens during the creation of the service request within the
Link Attributes window. At that point, you can specify which VLAN is translated to which VLAN. The
Link Attributes window is accessed after the UNI port is selected on the Attachment Tunnel Editor
window. Because you can set the VLAN translation type after the UNI selection, the UNI port display
list does not exclude any type for the UNI port. This is because:
•
The UNI port list has to include the regular trunk port, in case you later (on the Link Attributes
window) decide to perform no VLAN translation or 1:1 VLAN translation.
•
The UNI port list has to include an EWS (EPL) (Q-in-Q) port, in case you decide to do 2:1 VLAN
translation.
Even though you have all the ports to start with for VLAN translation, you must choose specific types
of ports, based on the type of VLAN translation. More specifically:
•
For no VLAN translation and 1:1 VLAN translation, you must choose an empty port or a trunk port
as the UNI.
•
For 2:1 VLAN translation, you must choose an empty port or a Q-in-Q port as the UNI port.
To help determine the proper port to use, you can click the Details button on the Attachment Tunnel
Editor window to display the port type and associated service with that port.
The following sections show how the VLAN translation is defined on the Link Attribute window for the
different types of VLAN translation.
No VLAN Translation
When you choose no VLAN translation, no additional information needs to be provided.
1:1 VLAN Translation
When you choose 1:1 VLAN translation, the window dynamically changes, as shown in Figure C-3.
Figure C-3
CE VLAN to be Translated From
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
C-3
Appendix C
Setting Up VLAN Translation
Setting Up VLAN Translation
In the empty field, you must enter which CE VLAN is to be translated from. The VLAN number must
be a number from 1 to 4096.
The PE VLAN that the CE VLAN is to be translated to can be “auto picked” or manually entered. Check
the VLAN ID AutoPick check box above (on the Link Attributes window) to have PE VLAN
automatically assigned. (See Figure C-4.)
Figure C-4
Automatic Selection of the PE VLAN
If you uncheck the VLAN ID AutoPick check box (see Figure C-5), the window displays a Provider
VLAN ID, where you can manually enter the PE VLAN.
Figure C-5
Manual Selection of the PE VLAN
Upon completion of the service request creation, ISC does an integrity check before saving the service
request. For 1:1 VLAN translation, ISC rejects the service request if the CE VLAN has been used for
another 1:1 VLAN translation on the same port.
2:1 VLAN Translation
When choosing 2:1 VLAN translation, the window dynamically changes, as shown in Figure C-6.
Figure C-6
Note
2:1 VLAN Translation Window
If the UNI port has been provisioned with EWS (EPL) service, the outer VLAN value is grayed out. (See
Figure C-7.)
Figure C-7
2:1 VLAN Translation with Outer VLAN Grayed Out
In 2:1 VLAN translation, there are three VLANs involved:
•
“A”—The CE VLAN to be translated from. You specify this in the “From CE VLAN field.” For
out-of-range translation, a value of “*” (asterisk character) should be provided
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
C-4
OL-21636-01
Appendix C
Setting Up VLAN Translation
Setting Up VLAN Translation
•
“B”—The PE VLAN that is the outer VLAN of the Q-in-Q port. You specify this in the “Outer
VLAN” field. You can choose this VLAN manually by entering a value, or you can choose the
AutoPick check box to have one automatically assigned.
•
“C”—The PE VLAN that the “A” and “B” VLANs are translated to. You specify this in the “VLAN
and Other Information” section above (on the Link Attributes window). (See Figure C-4 and
Figure C-5.)
You must specify VLAN “A” (the CE VLAN) and VLAN “C” (the PE VLAN translated to). For VLAN
“B” (the Q-in-Q outer VLAN), what to specify depends on the UNI port type:
•
If it is an empty port, you must specify VLAN “B.”
•
If it is an existing Q-in-Q port, then VLAN “B” has been defined, and it cannot be changed at this
point.
Some additional comments on 2:1 VLAN translation:
•
For 2:1 VLAN translation, if you build an ERS (EVPL) service on an empty port, then this UNI port
will be provisioned as an ERS (EVPL) service. If you later add an EWS (EPL) service to the same
port, the EWS (EPL) service will overwrite the previous ERS (EVPL) provisioning. The major
difference between ERS (EVPL) and EWS (EPL) is the L2PT BPDU treatment. For ERS (EVPL),
BPDU is blocked. For EWS (EPL), BPDU is tunneled.
•
As an ERS (EVPL) service, the 2:1 VLAN translation can share the same port, just like a regular
ERS (EVPL) port.
•
An ERS (EVPL) 2:1 service can be added on top of an existing EWS (EPL) service.
Upon completion of the service request creation, ISC does an integrity check before saving the service
request. For 2:1 VLAN translation, ISC rejects the service request if the CE VLAN and outer tag PE
VLAN combination has been used for another 2:1 VLAN translation on the same port.
Modifying a Service Request
For both 1:1 and 2:1 VLAN translation, you can perform the following modifications on an existing
service request:
•
Change to a new CE VLAN to be translated from.
•
All other normal changes for a service request are permitted.
However, the following modifications are not allowed:
•
You cannot change the VLAN translation type for a given AC. For instance, you cannot change from
2:1 to 1:1 VLAN translation.
•
You cannot change the place where 2:1 VLAN translation occurs.
Deleting a Service Request
During service request deletion, the following resources are released:
For 1:1 VLAN translation:
•
The CE VLAN becomes available to be translated again.
•
The PE VLAN is released.
•
If the link being deleted is the last link on the UNI port, then this port is set to new.
For 2:1 VLAN translation:
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
C-5
Appendix C
Setting Up VLAN Translation
Platform-Specific Usage Notes
•
The CE VLAN becomes available to be translated again.
•
The “translated to” PE VLAN is released.
•
If the link being deleted is the last “CE-PE” pair on this UNI port, and there is no EWS (EPL) service
on this port, then this port is set to new. In addition, the outer VLAN is released.
Platform-Specific Usage Notes
VLAN translation is available on 7600 and 3750 ME platforms. The 7600 and 3750 ME have different
ways to support VLAN translation. Not only is the command syntax different, but so is the place where
the VLAN translation is carried out. On the 7600, for 1:1 VLAN translation, the operation is done on the
PFC card. For 2:1 VLAN translation, the operation is done on the uplink GE-WAN (OSM module). On
the 3750 ME, however, both translations occur on the uplinks (ES ports).
VLAN Translation on the 3750
Be aware of the following points when performing VLAN translation on the 3750.
•
The 3750 where VLAN translation occurs should be designated as a U-PE or PE-AGG role, not
N-PE.
•
VLAN translation on the up link (ES) port should be performed on the Gigabit 1/1/1 or Gigabit 1/1/2
port.
•
If a 1:1 VLAN translation occurs on a ring that is made of 3750 PEs, all the 3750s use the ES port
as uplink ports (the “east” and “west” ports) to connect other ring nodes.
VLAN Translation on the 7600
Be aware of the following points when performing VLAN translation on the 7600.
•
1:1 VLAN translation always occurs on the UNI port. However, not every Ethernet interface will
support 1:1 VLAN translation. Such support is dependent on the line card.
•
2:1 VLAN translation always occurs on the GE-WAN port. The port must be an NNI uplink port.
•
2:1 VLAN translation only occurs on a 7600 that is a U-PE or a PE-AGG, not an N-PE. The reason
is when the 2:1 VLAN translation is performed on the GE-WAN interface, this interface can no
longer perform L3VPN and L2VPN service using the translated new VLAN. The L3/L2VPN service
has to be provisioned on another (N-PE) box.
Failed Service Requests When Hardware Does Not Support VLAN Translation
For the 1:1 VLAN translation feature, a service request goes to the Fail Deployed state if the target
hardware (line card) does not support the VLAN translation. The reason the service request goes to the
Fail Deployed state instead of Invalid is that ISC does not know beforehand whether a particular line
card will accept or reject the VLAN translation CLI commands. In this case, ISC attempts to push down
the commands and the deployment fails. An Invalid status means ISC detects something wrong (in
advance) and aborts the provisioning task. No CLI is pushed down in that case. This is a general behavior
of ISC when a given hardware does not support a feature. In these cases, it is the user’s responsibility to
select proper hardware to support the intended service.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
C-6
OL-21636-01
A P P E N D I X
D
Terminating an Access Ring on Two N-PEs
This appendix describes how to terminate an access ring on two N-PEs for redundancy in case an access
link goes down. It contains the following sections:
•
Overview, page D-1
•
Setting Up an NPC Access Ring with Two N-PEs, page D-3
•
Setting Up an NPC Access Ring with Two N-PEs, page D-3
•
Using N-PE Redundancy in FlexUNI/EVC Service Requests, page D-3
•
Additional Network Configurations and Sample Configlets, page D-5
Overview
ISC supports device-level redundancy in the service topology. This allows the service to remain active
in case one access link should drop. This is accomplished through support for provisioning termination
of access links against two different N-PEs. This is implemented by allowing an access ring to terminate
on two different N-PEs. This may also be described as a “dual-homed access ring.” The N-PEs are
connected by a logical link using loopback interfaces on the N-PEs. The redundant link starts from a
U-PE device and may, optionally, include PE-AGG devices. One attachment link is primary and one is
secondary. The selection is made when the Named Physical Circuit (NPC) is created. The terminating
device on the NPC acts as the primary N-PE, while the other N-PE on the same ring acts as the secondary
N-PE.
For backward compatibility, ISC continues to support provisioning services without redundant links, as
in previous releases.
Note
N-PE redundancy is only supported for FlexUNI/EVC services.
Note
MPLS service requests should not be deployed on access rings with two N-PEs. This might result in
errors with the generated configlets.
Figure D-1 and Figure D-2 show two network topologies which illustrate redundancy, starting from a
U-PE access node. Both topologies provide open segments for each uplink, starting from the U-PE and
terminating on the N-PE devices. The N-PEs are logically connected via loopback interfaces. Services
are configured on both of these Ethernet access links starting from the U-PE to two different N-PEs.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
D-1
Appendix D
Terminating an Access Ring on Two N-PEs
Overview
Figure D-1
N-PE Redundancy, Starting at the U-PE
N-PE-1
MPLS Core
204824
U-PE
Figure D-2
N-PE and PE-AGG Redundancy, Starting at the U-PE
PE-AGG-1
N-PE-1
MPLS Core
204825
U-PE
PE-AGG-2
N-PE-2
The first topology (N-PE redundancy starting at the U-PE, as shown in Figure D-1) provides the model
of fault recovery for the N-PE device. As shown in the diagram, there are two different outgoing
interfaces starting from the U-PE device. Each terminates at a different N-PE.
The second topology (N-PE and PE-AGG redundancy starting at the U-PE, as shown in Figure D-2)
provides fault recovery for both the PE-AGG and N-PE devices. The service switches over from the
primary to the secondary link when either the PE-AGG or the N-PE of the primary link fails.
For other network scenarios illustrating more complex topologies, see Additional Network
Configurations and Sample Configlets, page D-5.
The following list provides additional details about the implementation:
•
Using one U-PE and two N-PEs consumes one access link (AL).
•
When creating a service on a U-PE, the user specifies an NPC to be used. If the topology includes
an access ring with two N-PEs, then the service is configured on both N-PEs.
•
For Ethernet over MPLS (EoMPLS) pseudowire (PW) services, if there is N-PE redundancy on both
sides of the service provider network, two pseudowires are created. One N-PE is defined as primary
and the other as secondary, in order to determine the how the pseudowires connect. If the user
enables the PW Redundancy option, the primary and secondary on either end are also connected
with pseudowire redundancy.
•
For point-to-point (P2P) configurations, the two N-PEs use two separate pseudowires.
•
ISC supports the case in which the service is configured identically (except for the access interface)
on both N-PEs. This saves the user from having to enter data twice because the link attributes in the
service request workflow are common for both N-PEs that are part of the attachment circuit.
•
This feature is supported for both Cisco 7600 and Cisco ASR 9000 platforms. However, a single
service cannot include both 7600 and ASR 9000 platforms.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
D-2
OL-21636-01
Appendix D
Terminating an Access Ring on Two N-PEs
Setting Up an NPC Access Ring with Two N-PEs
•
Note
For the Cisco ASR 9000 platform, IOS XR version 3.7.3 and 3.9.0 are supported.
Check the on-line version of Release Notes for Cisco IP Solution Center, 6.0, for the most
current information on device and platform support, in case updates have occurred since the
publication of this guide.
The implementation of this feature is covered in more detail in the following sections.
Setting Up an NPC Access Ring with Two N-PEs
Terminating an NPC access ring on two N-PEs is achieved by using the standard method of setting up
an NPC ring in ISC. The basic steps for doing this are described the Cisco IP Solution Center
Infrastructure Reference, 6.0. Additional information is provided in this guide in the section Creating
Named Physical Circuits, page 2-8.
In normal cases, a ring would be closed by connecting the devices via physical interfaces. When
terminating an access ring on two different N-PEs, there is no need for a physical connection between
the N-PEs. However, ISC requires that a virtual link must be created between the N-PEs, in order to close
the ring. The virtual link is set up through the use of loopback interfaces. Figure D-3 shows the creation
of an NPC ring with loopback interfaces.
Figure D-3
NPC Ring with Loopback Interfaces Between N-PEs
In order to use loopback interfaces in a ring in this manner, you must enable the DCPL property
allowLoopbackIntfInNPC, which is accessed in the Host Configuration window under the folder
/repository/mlshare. When this DCPL property is set to true, ISC allows the use of loopback interfaces
in a ring.
Note
Note that ISC does not generate any configlets onto the loopback interfaces during deployment of the
service request.
Using N-PE Redundancy in FlexUNI/EVC Service Requests
Using a dual-homed access ring in a FlexUNI/EVC service request does not require any change in the
usual workflow in the ISC GUI. During creation of the FlexUNI/EVC service request, you select the
NPC which is associated with an NPC access ring terminating on two N-PEs, as shown Figure D-4.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
D-3
Appendix D
Terminating an Access Ring on Two N-PEs
Using N-PE Redundancy in FlexUNI/EVC Service Requests
Figure D-4
FlexUNI/EVC Service Request Editor Page, with N-PE Redundancy Option
Usage notes:
•
The service is configured on both N-PEs of the access ring.
•
Though there are two different N-PEs, only one access link is consumed.
•
You can modify the configuration redundant N-PEs before or after deploying the service request.
Modified configlets will be generated according to the changes made in service request.
•
The destined N-PE device on the NPC used in the service request is treated as the primary N-PE.
The other N-PE on the same ring is treated as the secondary N-PE. To change the primary and
secondary N-PE, you must modify the attachment circuits in the service request.
•
Configlets are generated according to the configuration specified in the service request. ISC
generates identical configlets on both of the N-PEs in the attachment circuit (AC). The Link
Attributes sections are common for both N-PEs.
•
For FlexUNI/EVC services, N-PE redundancy is supported for PSEUDOWIRE and VPLS core
connectivity types.
•
In case of VPLS core connectivity, all N-PEs in NPC rings are configured to have Layer 2 Virtual
Forwarding Interface (VFI), and all N-PEs on the same VPLS VPN participate in the VPLS service
at the same time.
•
In the case of PSEUDOWIRE core connectivity, the following notes apply:
– If there is N-PE redundancy on both sides, a point-to-point pseudo wire (PW) will be configured
between the N-PEs that were specified as the terminating N-PE devices during the NPC creation
(between primary N-PEs). One more point-to-point PW will be configured between the N-PEs
that were not specified as the terminating N-PE devices during NPC creation. The VC IDs of
these pseudowires will be common.
– If there is N-PE redundancy on only one side, then the Pseudowire Redundancy option must be
checked in the GUI (in the Service Request Details section of the of the FlexUNI(EVC) Service
Editor window). The primary PW will connect the primary N-PE of the dual-homed ring with
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
D-4
OL-21636-01
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
the N-PE of the single-homed ring, and the secondary PW will connect the secondary N-PE of
the dual-homed ring with the N-PE of the single-homed ring. ISC will issue a warning message
if you try to save the service request without enabling the Pseudowire Redundancy option.
Additional Network Configurations and Sample Configlets
This section provides additional network scenarios for reference, along with sample configlets for
associated network devices.
Example 1: Pseudowire Connectivity (A)
Figure D-5 illustrates a network configuration with pseudowire connectivity with dual-homed N-PEs on
both sides of the network and with pseudowire redundancy.
Figure D-5
Pseudowire Connectivity, Dual-Homed N-PEs on Both Sides of the Network, with
Pseudowire Redundancy
R1
PE1
PE3
R4
R3
PE2
PE4
R5
R2
204864
Primary Edge
Secondary Edge
Blocked Segment
Data Pseudowire
Control Pseudowire
Primary VC ID
Backup VC ID
Sample configlets for the devices are provided below.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
D-5
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
PE1
vlan <S-Vlan>
!
interface <UNI-to-R1>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE3 loopback> <PrimaryVcId> encapsulation mpls
backup peer <PE4 loopback> <BackupVcId>
PE2
vlan <S-Vlan>
!
interface <UNI-to-R3>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE4 loopback> <PrimaryVcId> encapsulation mpls
backup peer <PE3 loopback> <BackupVcId>
PE3
vlan <S-Vlan>
!
interface <UNI-to-R4>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE1 loopback> <PrimaryVcId> encapsulation mpls
backup peer <PE2 loopback> <BackupVcId>
PE4
vlan <S-Vlan>
!
interface <UNI-to-R5>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE2 loopback> <PrimaryVcId> encapsulation mpls
backup peer <PE1 loopback> <BackupVcId>
Example 2: Pseudowire Connectivity (B)
Figure D-6 illustrates a network configuration using pseudowire connectivity, with dual-homed N-PEs
on both sides of the network without pseudowire redundancy.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
D-6
OL-21636-01
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
Figure D-6
Pseudowire Connectivity, Dual-Homed N-PEs on Both Sides of the Network, with No
Pseudowire Redundancy
R1
PE1
PE3
R4
R3
PE2
PE4
R5
R2
204865
Primary Edge
Secondary Edge
Blocked Segment
Data Pseudowire
Control Pseudowire
Primary VC ID
Backup VC ID
Sample configlets for the devices are provided below.
PE1
vlan <S-Vlan>
!
interface <UNI-to-R1>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE3 loopback> <PrimaryVcId> encapsulation mpls
PE2
vlan <S-Vlan>
!
interface <UNI-to-R3>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE4 loopback> <PrimaryVcId> encapsulation mpls
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
D-7
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
PE3
vlan <S-Vlan>
!
interface <UNI-to-R4>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE1 loopback> <PrimaryVcId> encapsulation mpls
PE4
vlan <S-Vlan>
!
interface <UNI-to-R5>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE2 loopback> <PrimaryVcId> encapsulation mpls
Example 3: Pseudowire Connectivity (C)
Figure D-7 illustrates a network configuration using pseudowire connectivity with dual-homed N-PEs at
one side of the network and with pseudowire redundancy.
Pseudowire Connectivity, Dual-Homed N-PEs on One Side of the Network, with
Pseudowire Redundancy
R1
R2
PE2
R4
PE3
R5
PE1
R3
PE2
Primary Edge
Secondary Edge
Blocked Segment
Data Pseudowire
Control Pseudowire
Primary VC ID
Backup VC ID
204866
Figure D-7
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
D-8
OL-21636-01
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
Sample configlets for the devices are provided below.
PE1
vlan <S-Vlan>
!
interface <UNI-to-R1>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE2 loopback> <PrimaryVcId> encapsulation mpls
backup peer <PE3 loopback> <BackupVcId>
PE2
vlan <S-Vlan>
!
interface <UNI-to-R4>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE1 loopback> <PrimaryVcId> encapsulation mpls
PE3
vlan <S-Vlan>
!
interface <UNI-to-R5>
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan add <S-Vlan>
!
interface vlan <S-Vlan>
xconnect <PE1 loopback> <BackupVcId> encapsulation mpls
Example 4: VPLS Connectivity
Figure D-8 illustrates a network configuration using VPLS connectivity with dual-homed N-PEs on both
sides of the network.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
D-9
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
Figure D-8
VPLS Connectivity, Dual-Homed N-PEs on Both Sides of the Network
R1
PE1
PE3
R4
R3
PE2
PE4
R5
Primary Edge
Secondary Edge
Blocked Segment
Data Pseudowire
Control Pseudowire
204867
R2
Sample configlets for the devices are provided below.
PE1
vlan <S-Vlan>
!
l2 vfi <VFI-ID> manual
vpn id <S-Vlan>
neighbor <PE2> encapsulation mpls
neighbor <PE3> encapsulation mpls
neighbor <PE4> encapsulation mpls
!
interface vlan <S-Vlan>
xconnect vfi <VFI-ID>
!
interface <NNI-to-R1>
switchport trunk allowed vlan add <S-Vlan>
PE2
vlan <S-Vlan>
!
l2 vfi <VFI-ID> manual
vpn id <S-Vlan>
neighbor <PE1> encapsulation mpls
neighbor <PE3> encapsulation mpls
neighbor <PE4> encapsulation mpls
!
interface vlan <S-Vlan>
xconnect vfi <VFI-ID>
!
interface <NNI-to-R3>
switchport trunk allowed vlan add <S-Vlan>
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
D-10
OL-21636-01
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
PE3
vlan <S-Vlan>
!
l2 vfi <VFI-ID> manual
vpn id <S-Vlan>
neighbor <PE1> encapsulation mpls
neighbor <PE2> encapsulation mpls
neighbor <PE4> encapsulation mpls
!
interface vlan <S-Vlan>
xconnect vfi <VFI-ID>
!
interface <NNI-to-R5>
switchport trunk allowed vlan add <S-Vlan>
PE4
vlan <S-Vlan>
!
l2 vfi <VFI-ID> manual
vpn id <S-Vlan>
neighbor <PE1> encapsulation mpls
neighbor <PE2> encapsulation mpls
neighbor <PE3> encapsulation mpls
!
interface vlan <S-Vlan>
xconnect vfi <VFI-ID>
!
interface <NNI-to-R4>
switchport trunk allowed vlan add <S-Vlan>
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
D-11
Appendix D
Terminating an Access Ring on Two N-PEs
Additional Network Configurations and Sample Configlets
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
D-12
OL-21636-01
A P P E N D I X
E
ISC Layer 2 VPN Concepts
This appendix provides an overview of ISC Layer 2 VPN concepts. It contains the following sections.
•
Layer 2 Terminology Conventions, page E-1
•
L2VPN Service Provisioning, page E-5
•
VPLS Service Provisioning, page E-10
Layer 2 Terminology Conventions
Layer 2 service provisioning for the IP Solution Center (ISC) consists of the Layer 2 Virtual Private
Network (L2VPN) Service and the Virtual Private LAN Service (VPLS). The purpose of this section is
to clarify the terminologies used in ISC, as well in the industry at large, for these services.
There are three sets of terminologies in use:
•
The current Metro Ethernet Forum (MEF) terminology
•
The former MEF terminology
•
ISC terminology (which is close to the former MEF terminology)
MEF Terminology Conventions
In general, for L2VPN services, the MEF supports two general Ethernet service type constructs:
•
Ethernet Line (E-Line). Provides a point-to-point Ethernet Virtual Circuit (EVC).
•
Ethernet LAN (E-LAN). Provides a multipoint-to-multipoint EVC.
Two Ethernet services are available for each type. These are distinguished by the means of service
identification used at the user-to-network interface (UNIs), as follows:
•
Port based. All-to-one bundling. These are referred to as “private.”
•
VLAN-based. These services are multiplexed. The EVC is identified by a VLAN ID. These are
referred as “virtual private.”
Table E-1 summarizes these relationships.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-1
Appendix E
ISC Layer 2 VPN Concepts
Layer 2 Terminology Conventions
Table E-1
Ethernet Service Definitions
Service Type
Port-Based
VLAN-Based
E-Line
Ethernet Private Line (EPL)
Ethernet Virtual Private Line (EVPL)
E-LAN
Ethernet Private LAN (EP-LAN)
Ethernet Virtual Private LAN (EVP-LAN)
In addition to E-Line and E-LAN services, two additional service types are available for Layer 2:
•
Frame Relay over MPLS (FRoMLS)
•
ATM over MPLS (ATMoMPLS)
These service types are not covered in the current MEF documentation, in spite of the fact that the MEF
has merged with the Frame Relay forum.
Formerly, another terminology was used by the MEF for Layer 2 services. Table E-3 maps the older
terminology to the current one.
Table E-2
MEF Ethernet Service Term Mappings
Current MEF Term
Former MEF Term
L2VPN over MPLS Core
Ethernet Private Line (EPL)
Ethernet Wire Service (EWS)
Ethernet Virtual Private Line (EVPL)
Ethernet Relay Service (ERS)
ATM over MPLS (ATMoMPLS)
ATM over MPLS (ATMoMPLS)
Frame Relay over MPLS (FRoMPLS)
Frame Relay over MPLS (FRoMPLS)
VPLS over MPLS Core
Ethernet Private LAN (EP-LAN)
Ethernet Wire Service (EWS) or
Ethernet Multipoint Service (EMS)
Ethernet Virtual Private LAN (EVP-LAN)
Ethernet Relay Service (ERS) or
Ethernet Relay Multipoint Service (ERMS)
VPLS over Ethernet Core
Ethernet Private LAN (EP-LAN)
Ethernet Wire Service (EWS)
Ethernet Virtual Private LAN (EVP-LAN)
Ethernet Relay Service (ERS)
For additional information about MEF conventions and additional useful background information on
Metro Ethernet standards, see the MEF website at the following URL:
http://metroethernetforum.org
In particular, see the document Metro Ethernet Services Definitions Phase 2 available under the section
Information Center > MEF Technical Specifications on the MEF website for a useful presentation of
Metro Ethernet terms and definitions.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-2
OL-21636-01
Appendix E
ISC Layer 2 VPN Concepts
Layer 2 Terminology Conventions
Mapping MEF Terminologies to Network Technologies
The MEF terminology only describes the outside characteristics of a service, that is, what the service
looks like from the perspective of a customer looking in towards the user-to-network-interface (UNI)
device. It does not describe how the service is implemented.
For details about how these service are implemented, see the following URL:
http://www.cisco.com/go/ce
In particular, see the documentation on that site on the subject of Cisco IP Next-Generation Network
(NGN) Carrier Ethernet Design. The IP NGN Carrier Ethernet Design represents key elements of the
Cisco IP NGN architecture that enable a best-in-class implementation for consistent service delivery
optimized to meet the specific demands of each service. It is the end-to-end service transport foundation
from the network access to the IP/MPLS core. This design provides integrated linkages with the service
and application layer components to offer a converged, intelligent, reliable, and scalable network model
to meet current and future network service requirements.
The IP NGN Carrier Ethernet Design (see Figure E-1) provides a platform-independent architecture and
Ethernet-based services model across all Carrier Ethernet platforms. This allows service providers to
optimize service transport with the intelligence of appropriate networking technologies (such as
Ethernet, IP, MPLS, multicast, pseudowire, or hierarchical private virtual LAN services) to meet their
business and quality-of-experience goals.
Note
Real-world network implementations may implement only a subset of this very scalable architecture.
Figure E-1
IP NGN Carrier Ethernet Design
Subscriber Edge
Access
Carrier Ethernet
Aggregation
Intelligent
Services Edge
IP/MPLS
Core
Mobile/WiMAX
EFTTx
BNG
DSL/PON
Business
CPE
MSPP
Aggregation
Node
Distribution
(AN)
Node
(DN)
Core
MSE
Residential
Cable
CPE
204778
IPoDWDM
STB
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-3
Appendix E
ISC Layer 2 VPN Concepts
Layer 2 Terminology Conventions
ISC Terminology and Supported Network Types
This section discusses the ISC terminology for Layer 2 services and supported network types. ISC can
provision the following service types:
•
E-Line (EPL/EWS and EVPL/ERS)
•
E-LAN (EP-LAN and EVP-LAN/ERMS)
•
FRoMPLS
•
ATMoMPLS
ISC also supports provisioning Ethernet services on a network that consists only of Ethernet switches
(no MPLS), and this is referred to in ISC terminology as VPLS with L2 core.
Note
For E-Line and E-LAN services, we recommend using the FlexUNI/EVC service policy type (see the
appropriate chapters in this guide for how to create FlexUNI/EVC policies and service requests). You
might have existing services that have been provisioned using the L2VPN and VPLS service policy
types. These are still supported and can be maintained with those service types, but new services should
use the FlexUNI /EVC service policy type. For ATM and FRoMPLS services, use the L2VPN service
policy, as before.
In the ISC GUI and throughout this user guide, the naming conventions for these Ethernet services
appear. These align closely with the earlier MEF conventions. This is expected to be updated in future
releases of ISC. The equivalent terms used by the MEF forum are summarized in Table E-3, for
reference.
Table E-3
Ethernet Service Term Mappings
Term Used in ISC 5.2 GUI and This User Guide
Current MEF Equivalent Term
L2VPN over MPLS Core
Ethernet Wire Service (EWS)
Ethernet Private Line (EPL)
Ethernet Relay Service (ERS)
Ethernet Virtual Private Line (EVPL)
ATM over MPLS (ATMoMPLS)
—
Frame Relay over MPLS (FRoMPLS)
—
VPLS Over MPLS Core
Ethernet Wire Service (EWS) or
Ethernet Multipoint Service (EMS)
Ethernet Private LAN (EP-LAN)
Ethernet Relay Service (ERS) or
Ethernet Relay Multipoint Service (ERMS)
Ethernet Virtual Private LAN (EVP-LAN)
VPLS over Ethernet Core
Ethernet Wire Service (EWS)
Ethernet Private LAN (EP-LAN)
Ethernet Relay Service (ERS)
Ethernet Virtual Private LAN (EVP-LAN)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-4
OL-21636-01
Appendix E
ISC Layer 2 VPN Concepts
L2VPN Service Provisioning
L2VPN Service Provisioning
This section provides and overview of ISC provisioning for L2VPN services that provide Layer 2
point-to-point connectivity over an MPLS core. Cisco’s Any Transport over MPLS (AToM) enables
supports these services. These implementations, in turn, support service types, as follows:
– Ethernet Wire Service (EWS). The MEF term for this service is EPL.
– Ethernet Relay Service (ERS). The MEF term for this service is EVPL.
– ATM over MPLS (ATMoMPLS)
– Frame Relay over MPLS (FRoMPLS)
Instructions on creating policies and service requests for these services are provided in other chapters of
the guide. For more information, see the following sections:
•
Point-to-Point Ethernet (EWS and ERS) (EPL and EVPL), page E-5
•
ATM over MPLS (ATMoMPLS), page E-8
•
Frame Relay over MPLS (FRoMPLS), page E-9
Point-to-Point Ethernet (EWS and ERS) (EPL and EVPL)
The EWS and ERS services (also known as EPL and EVPL, respectively, in MEF terminology) are
delivered with the Cisco Metro Ethernet offering. The same network architecture can simultaneously
provide both ERS (EPL) and EWS (EVPL) connections to diverse customers. Additionally, this Metro
Ethernet infrastructure can be used for access to higher-level services, such as IP-based virtual private
networking, public internet communications, Voice over IP, or a combination of all applications.
Ethernet Wire Service (EWS or EPL)
An Ethernet Virtual Circuit (EVC) connects two physical User-to-Network Interfaces (UNI) such that
the connection appears like a virtual private line to the customer. VLAN transparency and control
protocol tunnelling are supplied by the implementation of 802.1Q-in-Q tag-stacking technology. Packets
received on one UNI are transported directly to the other corresponding UNI.
The MEF term for this service is EPL.
Ethernet Relay Service (ERS or EVPL)
An Ethernet Virtual Circuit (EVC) is used to logically connect endpoints, but multiple EVCs could exist
per single UNI. Each EVC is distinguished by 802.1q VLAN tag identification. The ERS network acts
as if the Ethernet frames have crossed a switched network, and certain control traffic is not carried
between ends of the EVC. ERS is analogous to Frame Relay where the CE-VLAN tag plays the role of
a Data-Link Connection Identifier (DLCI).
The MEF term for this service is EVPL.
Topology for L2VPN Ethernet Over MPLS (ERS and EWS) (EPL and (EVPL)
Ethernet Over MPLS (EoMPLS) is a tunnelling mechanism that allows the service provider to tunnel
customer Layer 2 traffic though a Layer 3 MPLS network. It is important to remember that EoMPLS is
a point-to-point solution only.
The following figures provide a reference for how EoMPLS is utilized. Ethernet Services can be
distributed to the end customer in two ways.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-5
Appendix E
ISC Layer 2 VPN Concepts
L2VPN Service Provisioning
•
Single PE scenario—The customer is directly connected to an Ethernet port on the N-PE in
Figure E-2.
Figure E-2
Single PE scenario
U_PE
PE_AGG
N_PE1
10.1.1.1
N_PE2
10.2.2.2
MPLS Core
U_PE
Single PE
scenario
Site B
CE
•
Figure E-3
138356
Site A
CE
Distributed PE scenario—The end customer is connected through an Access Domain to the N-PE in
Figure E-3. That is, there is a Layer 2 switching environment in the middle of CE and N-PE.
Distributed PE Scenario
Ethernet Services
U_PE
PE_AGG
N_PE2
10.2.2.2
N_PE1
10.1.1.1
MPLS Core
U_PE
Site A
CE
Site B
CE
138357
Distributed PE
scenario
In both cases, a VLAN is assigned in one of the following ways:
•
Automatically assigned by ISC from the VLAN pool that is predefined by the user.
•
Manually assigned by the user through the GUI or the North Bound Interface (NBI).
In EoMPLS, ISC creates a point-to-point tunnel and then targets the EoMPLS tunnel to the peer N-PE
router through which the remote site can be reached. The remote N-PE is identified by its loopback
address. In Figure E-4, N-PE1 and N-PE2 have 10.1.1.1 and 10.2.2.2 as loopback addresses. In
Figure E-4, Site A has been allocated a VLAN-100 and Site B a VLAN-200. You can have different
VLAN IDs at either end of the circuit because the VLANs have local significance only (that is, within
the Ethernet access domain which is delimited by the N-PE).
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-6
OL-21636-01
Appendix E
ISC Layer 2 VPN Concepts
L2VPN Service Provisioning
For the N-PE that is serving Site A, a VLAN interface (Layer 3 interface) is created to terminate all L2
traffic for the customer, and an EoMPLS tunnel is configured on this interface.
Note
This configuration is based on the Cisco 7600 Optical Services Router. Other routers, such as the Cisco
7200, have different configurations.
The VC ID that defines the EoMPLS tunnel is 200. (See Figure E-4.)
Figure E-4
Ethernet over MPLS Configuration
N_PE1
interface loopback0
ip address 10.1.1.1/32
N_PE2
interface loopback0
ip address 10.2.2.2/32
mpls label protocol ldp
mpls ldp router-id loopback0
mpls label protocol ldp
mpls ldp router-id loopback0
interface vlan 100
mpls 12transport route 10.2.2.2 200
interface vlan 200
mpls 12transport route 10.1.1.1 200
MPLS Core
VLAN 100
138358
N_PE2
10.2.2.2
N_PE1
10.1.1.1
VC ID must match
VC ID must be unique
between PE-POP pairs
VLAN 200
Note that the VC ID has to be the same on both ends of the EoMPLS tunnel. On each N-PE, there is
mapping done between the VLANs to the EoMPLS tunnel. (See Figure E-5.)
Figure E-5
EoMPLS Tunnel
Mapping VLAN ID to VC ID
VLAN 100
7
Mapping VC ID to VLAN ID
VLAN 200
VC ID = 7
Two mapping tables: VLAN ID <-> VC ID
97072
7
For the overall connection, this mapping is: VLAN ID <-> VC ID <-> VLAN ID.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-7
Appendix E
ISC Layer 2 VPN Concepts
L2VPN Service Provisioning
This VLAN-VC ID mapping lets the service provider reuse VLAN IDs in Access Domains. (See
Figure E-6.)
VLAN-VC ID Mapping
U_PE
PE_AGG
U_PE
VLAN 100
N_PE1
10.1.1.1
VC ID
200
Mapping
VLAN ID to VC ID
MPLS Core
N_PE2
10.2.2.2
VC ID
200
Mapping
VLAN 200
VLAN ID to VC ID
Site A
CE
Site B
CE
138359
Figure E-6
The VLAN IDs allocated and used at each access domain do not have to be the same.
ATM over MPLS (ATMoMPLS)
With Cisco ATM over MPLS (ATMoMPLS), Cisco supports ATM Adaptation Layer 5 (AAL5) transport
and Cell Relay over MPLS.
AAL5
AAL5 allows you to transport AAL5 PDUs from various customers over an MPLS backbone. ATM
AAL5 extends the usability of the MPLS backbone by enabling it to offer Layer 2 services in addition
to already existing Layer 3 services. You can enable the MPLS backbone network to accept AAL5 PDUs
by configuring the provider edge (PE) routers at both ends of the MPLS backbone.
To transport AAL5 PDUs over MPLS, a virtual circuit is set up from the ingress PE router to the egress
PE router. This virtual circuit transports the AAL5 PDUs from one PE router to the other. Each AAL5
PDU is transported as a single packet.
Cell Relay over MPLS
Cell Relay over MPLS allows you to transport ATM cells from various customers over an MPLS
backbone. ATM Cell Relay extends the usability of the MPLS backbone by enabling it to offer Layer 2
services in addition to already existing Layer 3 services. You can enable the MPLS backbone network
to accept ATM cells by configuring the provider edge (PE) routers at both ends of the MPLS backbone.
To transport ATM cells over MPLS, a virtual circuit is set up from the ingress PE router to the egress PE
router. This virtual circuit transports the ATM cells from one PE router to the other. Each MPLS packet
can contain one or more ATM cells. The encapsulation type is AAL0.
Topology for ATMoMPLS
Only the single PE scenario is supported. (See Figure E-7.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-8
OL-21636-01
Appendix E
ISC Layer 2 VPN Concepts
L2VPN Service Provisioning
Figure E-7
Configuring AAL5 and Cell Relay over MPLS
MPLS Core
PE
PE
ATM virtual circuits
CE
CE
CE
CE
138360
ATM
ATM
Frame Relay over MPLS (FRoMPLS)
With Cisco AToM for Frame Relay, customer Frame Relay traffic can be encapsulated in MPLS packets
and forwarded to destinations required by the customer. Cisco AToM allows service providers to quickly
add new sites with less effort than typical Frame Relay provisioning.
Frame Relay over MPLS enables a service provider to transport Frame Relay frames across an MPLS
backbone. This extends the reachability of Frame Relay and allows service providers to aggregate frame
transport across a common packet backbone. The service provider can integrate an existing Frame Relay
environment with the packet backbone to improve operational efficiency and to implement the
high-speed packet interfaces to scale the Frame Relay implementations.
Transporting Frame Relay frames across MPLS networks provides a number of benefits, including:
•
Frame Relay extended service.
•
Aggregation to a higher speed backbone, such as OC-192, to scale Frame Relay implementations.
•
Improved operational efficiency—the MPLS backbone becomes the single network that integrates
the various existing networks and services.
Topology for FRoMPLS
Only the single PE scenario is supported. (See Figure E-8.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-9
Appendix E
ISC Layer 2 VPN Concepts
VPLS Service Provisioning
Figure E-8
Frame Relay over MPLS
MPLS Core
PE
PE
Frame Relay DLCI
Frame
Relay
CE
CE
CE
138361
CE
Frame
Relay
VPLS Service Provisioning
VPLS services are multipoint. They provide multipoint connectivity over an MPLS or an Ethernet core.
These implementations, in turn, support service types, as follows:
•
VPLS over MPLS core:
– Ethernet Wire Service (EWS). This is also sometimes referred to as EMS, or Ethernet
Multipoint Service. The MEF term for this service is EP-LAN.
– Ethernet Relay Service (ERS). This is also sometimes referred to ERMS, or Ethernet Relay
Multipoint Service. The MEF term for this service is EVP-LAN.
•
VPLS over Ethernet core:
– Ethernet Wire Service (EWS). The MEF term for this service is EP-LAN.
– Ethernet Relay Service (ERS). The MEF term for this service is EVP-LAN.
Instructions on creating policies and service requests for these services are provided in other chapters of
the guide.
VPLS is a multipoint Layer 2 VPN that connects two or more customer devices using EoMPLS bridging
techniques. VPLS EoMPLS is an MPLS-based provider core, that is, the PE routers have to cooperate to
forward customer Ethernet traffic for a given VPLS instance in the core. A VPLS essentially emulates
an Ethernet switch from a user’s perspective. All connections are peers within the VPLS and have direct
communications. The architecture is actually that of a distributed switch. Multiple attachment circuits
have to be joined together by the provider core. The provider core has to simulate a virtual bridge that
connects these multiple attachment circuits together. To achieve this, all PE routers participating in a
VPLS instance form emulated VCs among them.
A Virtual Forwarding Instance (VFI) is created on the PE router for each VPLS instance. PE routers
make packet-forwarding decisions by looking up the VFI of a particular VPLS instance. The VFI acts
like a virtual bridge for a given VPLS instance. More than one attachment circuit belonging to a given
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-10
OL-21636-01
Appendix E
ISC Layer 2 VPN Concepts
VPLS Service Provisioning
VPLS can be connected to this VFI. The PE router establishes emulated VCs to all the other PE routers
in that VPLS instance and attaches these emulated VCs to the VFI. Packet forwarding decisions are
based on the data structures maintained in the VFI. All the PE routers in the VPLS domain use the same
VC-ID for establishing the emulated VCs. This VC-ID is also called the VPN-ID in the context of the
VPLS VPN.
For more information, see the following sections:
•
Multipoint EWS (EP-LAN) for an MPLS-Based Provider Core, page E-11
•
Multipoint ERS (EVP-LAN) for an MPLS-Based Provider Core, page E-11
•
Topology for MPLS-Based VPLS, page E-11
Multipoint EWS (EP-LAN) for an MPLS-Based Provider Core
With multipoint EWS (also known as EP-LAN in MEF terminology), the PE router forwards all Ethernet
packets received from an attachment circuit, including tagged, untagged, and Bridge Protocol Data Unit
(BPDU) to either:
•
Another attachment circuit or an emulated VC if the destination MAC address is found in the L2
forwarding table (VFI).
•
All other attachment circuits and emulated VCs belonging to the same VPLS instance if the
destination MAC address is a multicast/broadcast address or not found in the L2 forwarding table.
Multipoint ERS (EVP-LAN) for an MPLS-Based Provider Core
With multipoint ERS (also known as EVP-LAN in MEF terminology), the PE router forwards all
Ethernet packets with a particular VLAN tag received from an attachment circuit, excluding BPDU, to
another attachment circuit or an emulated VC if the destination MAC address is found in the L2
forwarding table (VFI). If the destination MAC address is not found or if it is a broadcast/multicast
packet, then it is sent on all other attachment circuits and emulated VCs belonging to the VPLS instance.
The demultiplexing VLAN tag used to identify a VPLS domain is removed prior to forwarding the
packet to the outgoing Ethernet interfaces or emulated VCs because it only has local significance.
Topology for MPLS-Based VPLS
From a customer point of view there is no topology for VPLS. All the CE devices are connected to a
logical bridge emulated by the provider core. Therefore, the CE devices see a single emulated LAN. (See
Figure E-9.)
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-11
Appendix E
ISC Layer 2 VPN Concepts
VPLS Service Provisioning
Figure E-9
CE
MPLS-Based VPLS Topology
CE Device Point-of-View
CE
Provider Core
Emulated LAN
CE
104081
CE
The PE routers must create a full-mesh of emulated virtual circuits (VCs) to simulate the emulated LAN
seen by the CE devices. Forming a full-mesh of emulated VCs simplifies the task of emulating a LAN
in the provider core. One property of a LAN is to maintain a single broadcast domain. That is, if a
broadcast, multicast, or unknown unicast packet is received on one of the attachment circuits, it has to
be sent to all other CE devices participating in that VPLS instance. The PE device handles this case by
sending such a packet on all other attachment circuits and all the emulated circuits originating from that
PE. With a full-mesh of emulated VCs, such a packet will reach all other PE devices in that VPLS
instance. (See Figure E-10.)
Figure E-10
Full Mesh of Emulated VCs
MPLS enabled core
forms Tunnel LSPs
Common VC ID
between PEs creates a
Virtual Switching Instance
PE
PE
MPLS
CE
Attachment VCs are
Port Mode or VLAN ID
Full Mesh of directed
LDP sessions
exchange VC Labels
CE
104082
CE
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-12
OL-21636-01
Appendix E
ISC Layer 2 VPN Concepts
VPLS Service Provisioning
VPLS for an Ethernet-Based (L2) Provider Core
With an Ethernet-based provider core, customer traffic forwarding is trivial in the core. VPLS for an
Ethernet-based provider core is a multipoint Layer 2 VPN that connects two or more customer devices
using 802.1Q-in-Q tag-stacking technology. A VPLS essentially emulates an Ethernet switch from a
users perspective. All connections are peers within the VPLS and have direct communications. The
architecture is actually that of a distributed switch.
For more information on VPLS for an Ethernet-based provided core, see the following sections:
•
Multipoint EWS (EP-LAN) for an Ethernet-Based Provider Core, page E-13
•
Multipoint ERS (EVP-LAN) for an Ethernet-Based Provider Core, page E-13
•
Topology for Ethernet-Based VPLS, page E-13
Multipoint EWS (EP-LAN) for an Ethernet-Based Provider Core
Multipoint EWS (also known as EP-LAN in MEF terminology) is a service that emulates a point-to-point
Ethernet segment. The EWS service encapsulates all frames that are received on a particular User to
Network Interface (UNI) and transports these frames to a single egress UNI without reference to the
contents contained within the frame. This service operation means that EWS can be used for untagged
or VLAN tagged frames and that the service is transparent to all frames offered. Because the EWS
service is unaware that VLAN tags might be present within the customer frames, the service employs a
concept of “All to One” bundling.
Multipoint ERS (EVP-LAN) for an Ethernet-Based Provider Core
Multipoint ERS (also known as EVP-LAN in MEF terminology) models the connectivity offered by
existing Frame Relay networks by using VLAN indices to identify virtual circuits between sites. ERS
does, however, offer a far greater degree of QoS functionality depending upon the service provider's
implementation and the customer's acceptance of VLAN indices that are administratively controlled by
the service provider. Additionally, ERS service multiplexing capability offers lower cost of ownership
for the enterprise as a single interface can support many virtual interfaces.
Topology for Ethernet-Based VPLS
Ethernet-based VPLS differs from the point-to-point L2VPN definitions of EWS (EP-LAN) and ERS
(EVP-LAN) by providing a multipoint connectivity model. The VPLS service does not map an interface
or VLAN to a specific point-to-point pseudowire, but instead it models the operation of a virtual Ethernet
switch. VPLS uses the customer’s MAC address to forward frames to the correct egress UNI within the
service provider’s network for the EWS (EP-LAN).
The EWS (EP-LAN) service emulates the service attributes of an Ethernet switch and learns source MAC
to interface associations, flooding unknown broadcast and multicast frames. Figure E-11 illustrates an
EWS (EP-LAN) VPLS topology.
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
E-13
Appendix E
ISC Layer 2 VPN Concepts
VPLS Service Provisioning
Figure E-11
VPLS EWS Topology
192.168.11.11/24
192.168.11.25/24
192.168.11.1/24
192.168.11.2/24
192.168.11.12/24
104080
Ethernet Core
The Ethernet Relay Service (ERS or EVP-LAN) offers the any-to-any connectivity characteristics of
EWS and the service multiplexing. This combination enables a single UNI to support a customer's
intranet connection and one or more additional EVCs for connection to outside networks, ISPs, or
content providers. Figure E-12 illustrates an ERS (EVP-LAN) VPLS multipoint topology.
Figure E-12
VPLS ERS (EVP-LAN) Multipoint Topology
.21
Service
Multiplexed UNI
.25
.11
Internet Access
Router
192.168.11.1/24
192.168.11.0/24
.2
104079
Internet
Security
Policy
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
E-14
OL-21636-01
I N D EX
with CE, creating
Numerics
8-2
without CE, creating
1 to 1 VLAN translation
C-3
audience
2 to 1 VLAN translation
C-4
auditing
3750
iii-xi
service requests
VLAN translation on
C-6
8-11
11-1, 11-12
autodiscovery
7600
creating NPC links through autodiscovery
VLAN translation on
C-6
autodiscovery, of L2 services
A
2-10
12-1
B
AAL5
E-8
bridge domain
access domains, creating
accessing, reports
2-4
using the Bridge Domain ID attribute in VPLS service
requests 10-13
13-1
Bridge Domain ID attribute
access rings
setting up an NPC access ring with two N-PEs
terminating an access ring on two N-PEs
using in VPLS service requests
D-3
D-1
terminating an access ring on two N-PEs,
overview D-1
C
terminating on two N-PEs
cell relay
2-10
using N-PE redundancy in FlexUNI/EVC service
requests D-3
assigning, roles (N-PE or U-PE)
over MPLS
setting in FlexUNI/EVC ATM-Ethernet policies
ATM link attributes
setting in FlexUNI/EVC ATM-Ethernet service
requests 6-18
E-8
ATM over MPLS (ATMoMPLS)
ATM policies
with CE, defining
7-33
without CE, defining
ATM service requests
7-36
E-8
E-8
CEs
2-1
creating an EWS (EPL) L2VPN service request with
CE 8-8
ATM interface attributes
ATMoMPLS
10-13
5-6
creating VPLS service requests with CE
10-2
defining an Ethernet EWS (EPL) policies with
CE 7-15
defining ATM policies with CE
7-33
defining Ethernet/EMS (EP-LAN) policies with
CE 9-32
defining Ethernet/ERMS (EVP-LAN) policies with
CE 9-22
defining Ethernet ERS (EVPL) policies with CE
defining frame relay policies with CE
7-3
7-28
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
IN-1
Index
defining MPLS/EMS (EP-LAN) policies with
CE 9-11
FlexUNI/EVC (ATM-Ethernet Interworking,
Pseudowire Core Connectivity, Multipoint
Circuit) A-47, A-53
defining MPLS/ERMS (EVP-LAN) policies with
CE 9-3
FlexUNI/EVC (ATM-Ethernet Interworking,
Pseudowire Core Connectivity, Point-to-Point
Circuit) A-46
configlet examples
ATM (Port Mode, Pseudowire Class, E-Line, L2VPN
Group Name, IOS XR Device) A-26
ATM over MPLS (VC Mode)
A-24
ATM over MPLS (VP Mode)
A-25
FlexUNI/EVC (AutoPick Service Instance
Name) A-41
FlexUNI/EVC (Local Connect Core Connectivity,
UNI, no Port Security, Bridge Domain) A-38
ERS (EVPL) (1 to 1 VLAN Translation)
A-7
ERS (EVPL) (2 to 1 VLAN Translation)
A-8
FlexUNI/EVC (Local Connect Core Connectivity,
UNI Port Security) A-36
ERS (EVPL) (NBI Enhancements for L2VPN, IOS
Device) A-10
FlexUNI/EVC (No AutoPick Service Instance Name,
No Service Instance Name) A-42
ERS (EVPL) (Point-to-Point)
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge
Domain, Pseudowire on SVI) A-39
A-4
ERS (EVPL) (Point-to-Point, UNI Port Security)
A-5
ERS (EVPL), EWS (EPL), ATM, or Frame Relay
(Additional Template Variables for L2VPN, IOS and
IOS XR Device) A-15
ERS (EVPL) and EWS (EPL) (Local Connect on
E-Line) A-14
ERS (EVPL) or EWS (EPL) (IOS XR Device)
A-11
ERS (Pseudowire Class, E-Line, L2VPN Group Name,
IOS XR Device) A-9
EWS (EPL) (Hybrid)
A-19
FlexUNI/EVC (Pseudowire Core Connectivity, no
Bridge Domain, no Pseudowire on SVI) A-40
FlexUNI/EVC (Pseudowire Core Connectivity, UNI,
and Pseudowire Tunneling) A-33
FlexUNI/EVC (Pseudowire Core Connectivity, UNI,
without Port Security, with Bridge Domain) A-32
FlexUNI/EVC (Pseudowire Core Connectivity, UNI
Port Security) A-31
FlexUNI/EVC (User-Provided Service Instance Name,
Local Core Connectivity) A-44
EWS (EPL) (NBI Enhancements for L2VPN, IOS
Device) A-23
FlexUNI/EVC (User-Provided Service Instance Name,
Pseudowire Core Connectivity) A-43
EWS (EPL) (Point-to-Point)
FlexUNI/EVC (User-Provided Service Instance Name,
VPLS Core Connectivity) A-45
A-16
EWS (EPL) (Point-to-Point, UNI Port Security, BPDU
Tunneling) A-17
EWS (EPL) (Pseudowire Class, E-Line, L2VPN
Group Name, IOS XR Device) A-22
FlexUNI/EVC (ATM-Ethernet Interworking, Local
Core Connectivity, Multipoint Circuit) A-49, A-50
FlexUNI/EVC (ATM-Ethernet Interworking, Local
Core Connectivity, Point-to-Point Circuit) A-48, A-51,
FlexUNI/EVC (VPLS Core Connectivity, no UNI Port
Security) A-35
FlexUNI/EVC (VPLS Core Connectivity, UNI Port
Security) A-34
Frame Relay (DLCI Mode)
Frame Relay over MPLS
A-28
A-27
A-54
overview
FlexUNI/EVC (ATM-Ethernet Interworking,
Pseudowire Core Connectivity, End-to-End
Circuit) A-52
VPLS (Multipoint, EMS/EP-LAN), BPDU
Tunneling) A-30
FlexUNI/EVC (ATM-Ethernet Interworking,
Pseudowire Core Connectivity, End-to-End Circuit, no
Bridge Domain) A-57
FlexUNI/EVC (ATM-Ethernet Interworking,
Pseudowire Core Connectivity, End-to-End Circuit,
with Bridge Domain) A-55, A-56
A-2
VPLS (Multipoint, ERMS/EVP-LAN)
A-29
configlets
(see also configlet examples)
viewing in service requests
A-1
11-9
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
IN-2
OL-21636-01
Index
configuring
D
basic ISC services
1-2
device settings to support ISC
data files
2-2
switches, in VTP transparent mode
the network
creating in service requests
2-2
see also templates and data files)
1-1
the network to support Layer 2 services
B-1
using in FlexUNI/EVC ATM-Ethernet service
requests 6-24
1-2
transport mode when pseudowire classes are not
supported 2-13
using in FlexUNI/EVC service requests
working with templates and data files
conventions
for terminology
ATM policies with CE
access domains
custom L2 and VPLS reports
customers
13-11
FlexUNI/EVC ATM-Ethernet service requests
FlexUNI/EVC Ethernet policies
L2 and VPLS reports
2-4
Ethernet EWS (EPL) policy with CE
2-10
FlexUNI/EVC ATM-Ethernet policies
FlexUNI/EVC Ethernet policies
2-8
NPCs through an NPC GUI editor
2-10
7-31
L2VPN group names for IOS XR devices
group names
2-9
defining for IOS XR devices
2-1
VC ID pools
2-7
VLAN pools
2-5
MPLS/EMS (EP-LAN) policies with CE
9-1
VPLS service requests
10-2
VPLS service requests with CE
10-2
VPLS service requests without CE
defining
setting up
10-6
2-4
1-2
2-14
7-1
9-11
MPLS/EMS (EP-LAN) policies without CE
9-16
MPLS/ERMS (EVP-LAN) policies with CE
9-3
MPLS/ERMS (EVP-LAN) policies without CE
regions
sites
2-3
2-4
VPLS policies
VPNs
9-7
2-3
service providers
customers
5-2
3-6
L2VPN policies
VPLS policies
7-22
7-28
frame relay policies without CE
2-11
pseudowire classes for IOS XR devices
target devices
frame relay policies with CE
2-8
7-9
7-15
Ethernet EWS (EPL) policy without CE
8-2
NPC links through the autodiscovery process
ring-only NPCs
7-3
Ethernet ERS (EVPL) policies without CE
7-1
9-22
Ethernet/ERMS (EVP-LAN) policies without
CE 9-27
Ethernet ERS (EVPL) policies with CE
4-2
13-1
L2VPN service requests
9-32, 9-37
Ethernet/ERMS (EVP-LAN) policies with CE
6-2
3-1
FlexUNI/EVC Ethernet service requests
7-36
Ethernet/EMS (EP-LAN) policies with CE
FlexUNI/EVC ATM-Ethernet interworking
policies 5-1
pseudowire classes
B-1
7-33
ATM policies without CE
2-4
L2VPN policies
4-22
defining
1-4
creating
NPCs
B-12
9-1
2-4
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
IN-3
Index
deploying
service requests
multipoint EWS (EP-LAN) for an Ethernet-based
provider core E-13
11-1, 11-2
deploying service requests
multipoint EWS (EP-LAN) for an MPLS-based
provider core E-11
11-1
devices
EWS (EPL) service requests
configuring device settings
2-2
with CE, creating
creating and modifying pseudowire classes for IOS
XR devices 2-10
device roles with FlexUNI/EVC
without CE, creating
8-16
3-5
setting loopback addresses on N-PE devices
setting up
8-8
2-2
F
1-2
setting up for IOS XR support
setting up target devices
FlexUNI/EVC
2-3
device roles with FlexUNI/EVC
2-1
features of
direct connect links
3-2
setting in FlexUNI/EVC ATM-Ethernet service
requests 6-8
IOS platform support
setting up in FlexUNI/EVC service requests
overview of support in ISC
documentation, obtaining
4-10
iii-xiv
3-5
3-3
IOS XR platform support
3-4
3-1
platform support for FlexUNI/EVC in ISC 6.0
topology overview for FlexUNI/EVC
3-3
3-5
FlexUNI/EVC ATM-Ethernet policies
E
enabling template association in FlexUNI/EVC
ATM-Ethernet policies 5-19
ERS
creating
5-1
defining
5-2
enabling template association in
overview
multipoint ERS (EVP-LAN) for an Ethernet-based
provider core E-13
multipoint ERS (EVP-LAN) for an MPLS-based
provider core E-11
with CE, creating
5-7
setting interface attributes in
5-12
creating
7-9
5-10
5-10
6-2
local core connectivity in
7-15
managing
6-1
Ethernet EWS (EPL) policy
modifying
6-23
without CE, defining
5-4
FlexUNI/EVC ATM-Ethernet service requests
Ethernet EWS (EPL) policies
with CE, defining
5-8
setting VLAN rewrite criteria attributes in
7-3
without CE, defining
setting FlexUNI attributes in
5-6
setting VLAN matching criteria attributes in
8-11
Ethernet ERS (EVPL) policies
with CE, defining
setting ATM interface attributes in
setting service options in
8-2
without CE, creating
5-1
setting service attributes in
ERS (EVPL) service requests
5-19
overview
7-22
Ethernet relay service (ERS or EVPL)
Ethernet wire service (EWS or EPL)
E-5
E-5
6-1
pseudowire core connectivity
saving
6-3
6-24
setting ATM link attributes
EWS
6-6
6-18
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
IN-4
OL-21636-01
Index
setting direct connect links in
6-8
G
setting links with L2 access nodes
6-22
setting service request details for
setting up links to N-PEs within
getting started
6-3
overview
6-8
using templates and data files with
tasks
6-24
1-1
1-1
FlexUNI/EVC Ethernet policies
defining
3-6
setting FlexUNI attributes in
3-10
setting interface attributes in
3-16
setting service attributes in
setting service options in
H
history, viewing in service requests
3-11
3-8
setting VLAN matching criteria attributes in
setting VLAN rewrite criteria attributes in
template association in
I
3-13
3-14
installing ISC and configuring the network
3-23
setting in FlexUNI/EVC policies
4-1
managing
4-1
modifying
4-21
4-7
5-12
3-16
IOS platform support for FlexUNI/EVC
local core connectivity
3-3
IOS XR
creating and modifying pseudowire classes for IOS
XR devices 2-10
pseudowire core connectivity
saving
setting in FlexUNI/EVC ATM-Ethernet policies
4-2
introduction
1-1
interface attributes
FlexUNI/EVC Ethernet service requests
creating
11-9
platform support for FlexUNI/EVC
4-3
setting up devices to support
4-23
setting direct connect links
setting links with L2 Access nodes
setting up links to the N-PE
VPLS core connectivity
defining L2VPN group names for
4-20
2-14
ISC services
4-2
setting up
4-9
using templates and data files in
2-3
IOS XR devices
4-10
setting service request details in
3-4
2-1
4-22
4-5
L
FlexUNI attributes
setting in FlexUNI/EVC ATM-Ethernet policies
setting in FlexUNI/EVC Ethernet policies
frame relay over MPLS (FRoMPLS)
7-28
without CE, defining
7-31
frame relay service requests
with CE, creating
8-2
without CE, creating
FRoMPLS
E-9
L2VPN
concepts
E-1
ISC terminology and supported network types
service provisioning
frame relay policies
with CE, defining
E-9
3-10
5-7
8-11
E-4
E-5
terminology conventions
E-1
L2VPN Ethernet over MPLS (ERS and EWS) (EPL and
(EVPL) E-5
L2VPN policies
creating
7-1
defining
7-1
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
IN-5
Index
defining an Ethernet ERS (EVPL) policy with CE
mapping MEF terminologies to network
technologies E-3
7-3
defining an Ethernet ERS (EVPL) policy without
CE 7-9
defining an Ethernet EWS (EPL) policy with CE
terminology conventions
7-15
defining an Ethernet EWS (EPL) policy without
CE 7-22
Metro Ethernet Forum (see MEF)
FlexUNI/EVC ATM-Ethernet service requests
FlexUNI/EVC service requests
8-2
L2VPN service requests
creating an ERS (EVPL), ATM, or frame relay L2VPN
service request with CE 8-2
pseudowire class objects
VPLS service requests
creating an EWS (EPL) L2VPN service request with
CE 8-8
monitoring
creating an EWS (EPL) L2VPN service request
without CE 8-16
multipoint
8-1
modifying
8-20
8-20
2-10
2-12
10-10
11-1, 11-10
ERS (EVP-LAN) for an Ethernet-based provider
core E-13
8-1
managing
saving
service requests
6-23
4-21
pseudowire classes for IOS XR devices
creating an ERS (EVPL), ATM, or frame relay L2VPN
service request without CE 8-11
introducing
E-1
modifying
L2VPN service requests
creating
E-1
ERS (EVP-LAN) for an MPLS-based provider
core E-11
EWS (EP-LAN) for an Ethernet-based provider
core E-13
8-26
links
creating NPC links through autodiscovery
EWS (EP-LAN) for an MPLS-based provider
core E-11
2-10
setting up links with L2 Access nodes in
FlexUNI/EVC service requests 4-20
viewing in service requests
11-8
N
local core connectivity
in FlexUNI/EVC ATM-Ethernet service requests
in FlexUNI/EVC service requests
6-6
setting up for an N-PE
2-8
negate templates, using to decommission template
configurations B-13
4-7
loopback addresses
setting on N-PE devices
Named Physical Circuits (see NPCs)
NPCs
2-2
creating
1-3
2-8
creating NPC links through autodiscovery
creating ring-only NPCs
2-9
creating through an NPC GUI editor
M
setting up
managing
2-10
2-8
1-3
N-PEs
FlexUNI/EVC ATM-Ethernet service requests
FlexUNI/EVC Ethernet service requests
L2VPN service requests
VPLS service requests
6-1
4-1
8-1
10-1
MEF
assigning roles for
2-1
setting loopback address on
2-2
setting up a loopback address for
1-3
setting up links to N-PEs in FlexUNI/EVC
ATM-Ethernet service requests 6-8
terminating an access ring on two N-PEs
D-1, D-3
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
IN-6
OL-21636-01
Index
using N-PE redundancy in FlexUNI/EVC service
requests D-3
setting up
1-2
pseudowire classes
configuring transport mode when pseudowire classes
are not supported 2-13
O
creating
objective
pseudowire class objects
iii-xi
organization
2-11
modifying
iii-xi
2-12
pseudowire core connectivity
overview
of FlexUNI/EVC ATM-Ethernet policies
of FlexUNI/EVC ATM-Ethernet service requests
of FlexUNI/EVC support in ISC
in FlexUNI/EVC ATM-Ethernet service requests
5-1
in FlexUNI/EVC service requests
6-1
6-3
4-3
3-1
R
P
regions, defining
PE-AGGS
selectively determining templates for
platform support for FlexUNI/EVC
B-9
iii-xii
relay service, Ethernet
E-5
accessing
Ethernet (EWS and ERS) (EPL and EVPL)
E-5
13-1
creating custom L2 and VPLS reports
generating L2 and VPLS reports
policies
associating templates and data files to
B-5
creating FlexUNI/EVC Ethernet policies
creating with VLAN translation
overview of L2VPN policies
overview of VPLS policies
3-1
C-2
L2 end-to-end wire report
L2 PE service report
L2 VPN report
overview
1-4
overview of template support in
B-4
B-4
13-1
13-3
13-7
13-1
VPLS attachment circuit report
VPLS VPN report
13-8
13-10
13-11
resources
1-4
setting up ISC resources
pools
1-3
rings
2-7
pools (see entry by type of pool)
13-11
13-6
VPLS PE service report
1-4
using templates and data files with
creating VC ID pools
related documentation
reports
3-3
point-to-point
policies (see also by type)
2-3
2-5
providers
multipoint ERS (EVP-LAN) for an Ethernet-based
provider core E-13
creating ring-only NPCs
2-9
terminating access rings on two N-PEs
2-10
roles
device roles with FlexUNI/EVC
3-5
multipoint ERS (EVP-LAN) for an MPLS-based
provider core E-11
multipoint EWS (EP-LAN) for an Ethernet-based
provider core E-13
multipoint EWS (EP-LAN) for an MPLS-based
provider core E-11
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
IN-7
Index
states of
S
11-4
using templates with
saving
verifying
FlexUNI/EVC ATM-Ethernet service requests
FlexUNI/EVC service requests
L2VPN service requests
VPLS service requests
6-24
4-23
8-26
setting in FlexUNI/EVC ATM-Ethernet policies
setting in FlexUNI/EVC policies
1-4
ATM link attributes in FlexUNI/EVC ATM-Ethernet
service requests 6-18
5-8
3-11
service options
setting in FlexUNI/EVC ATM-Ethernet policies
setting in FlexUNI/EVC Ethernet policies
5-4
3-8
direct connect links in FlexUNI/EVC ATM-Ethernet
service requests 6-8
FlexUNI attributes in FlexUNI/EVC ATM-Ethernet
policies 5-7
FlexUNI attributes in policies
3-10
interface attributes in FlexUNI/EVC ATM-Ethernet
policies 5-12
2-3
E-5
interface attributes in FlexUNI/EVC policies
service request details
setting for FlexUNI/EVC ATM-Ethernet service
requests 6-3
setting in FlexUNI/EVC Ethernet service
requests 4-2
service requests
associating templates and data files to
auditing
service requests (see also by type)
ATM interface attributes in FlexUNI/EVC
ATM-Ethernet policies 5-6
service attributes
service provisioning, for L2VPN
11-3
setting
10-14
service providers, defining
B-10, B-14
B-11
3-16
links with L2 access nodes in FlexUNI/EVC
ATM-Ethernet service requests 6-22
loopback addresses on N-PE devices
2-2
service attributes in FlexUNI/EVC ATM-Ethernet
policies 5-8
service attributes in FlexUNI/EVC policies
3-11
service options in FlexUNI/EVC ATM-Ethernet
policies 5-4
11-1, 11-12
choosing templates and data files in the service request
workflow B-14
service options in FlexUNI/EVC policies
configlets, viewing
service request details for FlexUNI/EVC
ATM-Ethernet service requests 6-3
11-9
3-8
creating a data file in the service request
workflow B-16
service request details in FlexUNI/EVC Ethernet
service requests 4-2
creating data files in
VLAN matching criteria attributes in FlexUNI/EVC
ATM-Ethernet policies 5-10
B-12
creating with VLAN translation
C-3
decommissioning service requests with added
templates B-18
VLAN matching criteria attributes in FlexUNI/EVC
policies 3-13
deploying
VLAN rewrite criteria attributes in FlexUNI/EVC
ATM-Ethernet policies 5-10
11-1, 11-2
history, viewing
links, viewing
monitoring
11-9
VLAN rewrite criteria attributes in FlexUNI/EVC
policies 3-14
11-8
11-1, 11-10
setting up
overview of L2VPN service requests
over view of VPLS service requests
pre-deployment changes
1-4
1-4
11-1
service request details, viewing
basic ISC services
customers
devices
11-7
1-2
1-2
1-2
devices for IOS XR support
2-3
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
IN-8
OL-21636-01
Index
direct connect links in FlexUNI/EVC service
requests 4-10
creating a data file in the service request
workflow B-16
ISC resources
creating data files during service request
creation B-12
ISC Services
1-3
2-1
decommissioning service requests with added
templates B-18
links to N-PEs in FlexUNI/EVC ATM-Ethernet
service requests 6-8
overview
links to the N-PEs in FlexUNI/EVC service
requests 4-9
B-1
overview support in ISC policies
B-4
links with L2 Access nodes in FlexUNI/EVC service
requests 4-20
selectively determining templates for U-PE and
PE-AGG devices B-9
NPCs
summary of template manager features
1-3
N-PE loopback address
providers
associating to a service request
C-1
using with ISC policies
1-3
workflow
service requests
B-10, B-14
viewing from the service requests window
2-4
states
B-18
B-3
terminology conventions
11-4
1-4
ISC terminology and supported network types
subtemplates
associating during service provisioning
L2VPN
B-11
MEF
switches
configuring in VTP transparent mode
E-4
E-1
E-1, E-3
topology
2-2
for ATMoMPLS
E-8
for Ethernet-based VPLS
T
for FRoMPLS
templates
B-4
using with service requests
sites
defining
B-11
using negate templates to decommission template
configurations B-13
2-1
VLAN translation
VPNs
templates and data files
1-3
1-2
target devices
B-1
E-13
E-9
for L2VPN Ethernet over MPLS (ERS and EWS) (EPL
and (EVPL) E-5
5-19
(see also templates and data files)
B-1
for MPLS-based VPLS
enabling template association in FlexUNI/EVC
policies 3-23
using in FlexUNI/EVC ATM-Ethernet service
requests 6-24
using in FlexUNI/EVC service requests
working with templates and data files
E-11
overview for FlexUNI/EVC
3-5
transport mode, configuring transport mode when
pseudowire classes are not supported 2-13
4-22
B-1
U
templates and data files
U-PEs
associating subtemplates during service
provisioning B-11
associating to a policy
assigning roles for
selectively determining templates for
B-5
choosing in the service request workflow
2-1
B-9
B-14
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
IN-9
Index
V
VC ID pools, creating
2-7
verifying, service requests
configlets in service requests
11-9
9-1
Ethernet/ERMS (EVP-LAN) policy without CE,
defining 9-27
11-8
11-7
MPLS/EMS (EP-LAN) policy with CE, defining
service request details in service requests
11-7
templates from the service requests window
B-18
VLAN matching criteria attributes
setting in FlexUNI/EVC ATM-Ethernet policies
setting in FlexUNI/EVC policies
VLAN pools, creating
defining
Ethernet/ERMS (EVP-LAN) policy with CE,
defining 9-22
viewing
service request details
9-1
Ethernet/EMS (EP-LAN) policy with CE,
defining 9-32, 9-37
11-3
links in service requests
creating
5-10
MPLS/EMS (EP-LAN) policy without CE,
defining 9-16
MPLS/ERMS (EVP-LAN) policy with CE,
defining 9-3
MPLS/ERMS (EVP-LAN) policy without CE,
defining 9-7
3-13
2-5
VPLS service requests
VLAN rewrite criteria attributes
creating
setting in FlexUNI/EVC ATM-Ethernet policies
setting in FlexUNI/EVC policies
5-10
3-14
10-2
creating VPLS service requests with CE
introducing
C-3
managing
10-1
2 to1 VLAN translation
C-4
modifying
10-10
C-2
saving
deleting a service request
C-3
no VLAN translation
overview
defining
setting up
C-5
2-4
1-3
VTP transparent mode, configuring switches in
C-3
2-2
C-1
platform-specific usage notes
setting up
10-13
VPNs
failed service requests due to hardware that does not
support VLAN translation C-6
modifying a service request
10-14
using the Bridge Domain ID attribute in
C-5
10-6
10-1
1 to1 VLAN translation
creating a service request with
10-2
creating VPLS service requests without CE
VLAN translation
creating a policy with
9-11
C-6
C-1
VLAN translation on the 3750
C-6
VLAN translation on the 7600
C-6
VPLS
connectivity in FlexUNI/EVC service requests
for an Ethernet-based (L2) provider core
service provisioning
4-5
E-13
E-10
topology for Ethernet-based VPLS
topology for MPLS-based VPLS
E-13
E-11
VPLS policies
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
IN-10
OL-21636-01
Download PDF