mODEL 2T2036E TWO 24 QUART / JACKETED TILTING

mODEL 2T2036E TWO 24 QUART / JACKETED TILTING
Item # _____________________________
C.S.I. Section 11420
MODEL 2T2036E
TWO 24 QUART 2/3 JACKETED TILTING
KETTLES ON ELECTRIC BOILER BASE
STANDARD FEATURES
■ Two 2/3 jacketed tilting steam kettles, 24 quart capacity
each.
■ Fully welded hemispheric bottom kettle with type 304 stainless steel jacket and type 316 stainless steel liner. Jacket
tested to 50 psi (3.4 kg/cm2).
■ 12" single temperature deck mounted faucet.
■ CSD-1 code compliant boiler.
■ Electric 24 KW steam boiler.
■ Requires a 208 or 240 volt, 60 Hz, 3 phase power supply
and a separate 120 volt, 60 Hz, 1 phase control circuit,
3 amp.
■ Water filter system, SPS620V. Includes second year extended
limited water associated parts and labor warranty.
■ One year limited parts and labor warranty.
OPTIONS
SPECIFICATIONS:
Two 24 quart 2/3 jacketed tilting steam kettles mounted on a
36" wide electric boiler base, Vulcan-Hart Model No. 2T2036E.
Steam jacketed kettles mounted on 28" high base cabinet
with front full height doors, slip-off stainless steel side and
­aluminized rear panel with 6" adjustable legs with flanged feet
for anchoring. Fully welded hemispheric bottom kettle with
type 304 stainless steel jacket and type 316 stainless steel
liner. Jacket tested to 50 psi (3.4 kg/cm2). Steam control valve
on right trunnion leg. 12" single temperature deck mounted
faucet. Requires a 208 or 240 volt, 60 hz, 3 phase power
supply and a separate 120 volt, 60 Hz, 1 phase control circuit,
3 amp.
Exterior dimensions:
Cabinet: 36"w x 33"d x 28"h on 6" adjustable legs. ­Overall
height to the lip of the kettles - 46", to the top of the
handle - 54".
U L listed. Classified by U L to NSF Std. #4. Meets ASME
Code.
■ Correction package.
- Cabinet door with hasp (lock by others).
- Security type tamper resistant fasteners.
- Front flanged feet.
■ Stainless steel finishing back.
■ Tilting kettle strainer (one) (two).
■ 12" dual temperature faucet.
■ Single phase on 24 KW boiler.
■ Stepdown transformer (eliminates 120 volt connection).
■ 36 KW boiler, 3 phase only.
■ 42/48 KW boiler, 3 phase only.
■ 480 volt, 60 Hz, 3 phase, includes stepdown transformer.
■ Mount and interconnect kettle with boiler base at factory.
Includes steam supply piping. Shipped on one skid.
■ Second year extended limited parts and labor warranty.
ACCESSORIES
■ Stainless steel back panel.
■ Lift-off cover (one) (two).
■ Contour measuring strip.
■ Single perforated stainless steel basket (one) (two).
F-32379 (10-03)
VULCAN-HART COmpany, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
MODEL: 2T2036E Two 24 Quart 2/3 Jacketed Tilting Kettles On Electric Boiler Base
■ Steam control valve on right trunnion leg.
A2780
ISO9001
Vulcan-Hart Co.
■ Steam jacketed kettles mounted on 28" high base cabinet
with front full height doors, slip-off stainless steel side and
aluminized rear panel with 6" adjustable legs with flanged
feet for anchoring.
MODEL 2T2036E
TWO 24 QUART 2/3 JACKETED TILTING
KETTLES ON ELECTRIC BOILER BASE
SERVICE CONNECTIONS:
A Electrical Connection for Boiler Heat: Junction box see capacity
chart.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE
HARDNESS*
SILICA
TOTAL CHLORIDE
pH RANGE
UN-DISSOLVED SOLIDS
* 17.1 ppm = 1 grain of hardness
B Electrical Connection for Controls: 120/60/1. 300 watt maximum,
power supply with grounding wire required.
20 - 60 psig
less than 3 grains
less than 13 ppm
less than 4.0 ppm
7-8
less than 5 microns
C Drain: Condensate box, compartment and boiler, 11/4" NPT. (Provide
an open air type drain within 12" of condensate box and for best results
at a distance so that steam vapors will not enter the steamer from
underneath the control area. Do not connect solidly to any drain
connection.)
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.
D Cold Water Connections (2):
D1 Treated Cold Water Connection: 1/4" NPT for boiler feed. Inlet
water pressure between 20 and 80 psi.
D2 Untreated Cold Water Connection: 1/4" NPT for condensate
box. Inlet water pressure between 20 and 80 psi.
E
AMPS PER LINE
208V
240V
480V
3 PHASE-4 WIRE
220/380V
240/415V
100
67
58
29
34
NA
100
87
44
50
NA
NA
117
NA
NA
NA
NA
NA
NA
116
58
67
1 PHASE
KW
INPUT
208V
240V
24
116
36
NA
42
48
3 PHASE
Water: For swing faucet, (single) (dual) temperature, 1/4"
tubing.
NOTE:
• Dimensions which locate the above connections have a
tolerance of + or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and
other specific code requirements is the responsibility of the
owner and installer. It is the responsibility of the owner and
installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited
temperatures of the plastic. Boiler purge temperatures may
exceed 180°F. The installer may be required to provide
means to reduce boiler purge water temperature to be that of
the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation
only and is not intended for home use.
EQUIPMENT CLEARANCE: Rear: 2" Right: 0" Left: 0"
BRIMFUL CAPACITIES (in 4 oz. servings):
24 quarts / 6 gallons / 22.5 liters - 192 servings.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32379 (10-03)
VULCAN-HART COmpany, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement