advertisement
Modular Crescent Cuber
Models
KM-1100MAH, MWH, MRH
KM-1340MAH, MWH, MRH
KM-1601MRH/3
“A Superior Degree of Reliability” www.hoshizaki.com
INSTRUCTION MANUAL
Issued: 4-28-2015
WARNING
Only qualified service technicians should install and service the appliance. To obtain the name and phone number of your local Hoshizaki Certified Service
Representative, visit www.hoshizaki.com. No installation or service should be undertaken until the technician has thoroughly read this Instruction Manual.
Likewise, the owner/manager should not proceed to operate the appliance until the installer has instructed them on its proper operation. Failure to install, operate, and maintain the appliance in accordance with this manual will adversely affect safety, performance, component life, and warranty coverage and may result in costly water damage. Proper installation is the responsibility of the installer. Product failure or property damage due to improper installation is not covered under warranty.
Hoshizaki provides this manual primarily to assist qualified service technicians in the installation, maintenance, and service of the appliance.
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, send an e-mail message, or write to the Hoshizaki Technical
Support Department for assistance.
Phone: 1-800-233-1940; (770) 487-2331
Fax: 1-800-843-1056; (770) 487-3360
E-mail: [email protected]
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: Hoshizaki Technical Support Department
NOTE: To expedite assistance, all correspondence/communication MUST include the following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem.
2
IMPORTANT
This manual should be read carefully before the appliance is installed and operated.
Read the warnings and guidelines contained in this manual carefully as they provide essential information for the continued safe use and maintenance of the appliance. Retain this manual for any further reference that may be necessary.
CONTENTS
4. Remote Condenser Unit URC-14F (use with KM-1100MRH and KM-1340MRH) ...11
5. Remote Condenser Unit URC-22F (use with KM-1601MRH/3) ..............................11
3
Important Safety Information
Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, damage to the appliance, or damage to property.
WARNING
Indicates a hazardous situation which could result in death or serious injury.
NOTICE Indicates a situation which could result in damage to the appliance or property.
IMPORTANT Indicates important information about the installation, use, and care of the appliance.
WARNING
The appliance should be destined only to the use for which it has been expressly conceived. Any other use should be considered improper and therefore dangerous.
The manufacturer cannot be held responsible for injury or damage resulting from improper, incorrect, and unreasonable use. Failure to install, operate, and maintain the appliance in accordance with this manual will adversely affect safety, performance, component life, and warranty coverage and may result in costly water damage.
To reduce the risk of death, electric shock, serious injury, or fire, follow basic precautions including the following:
• Only qualified service technicians should install and service the appliance.
• The appliance must be installed in accordance with applicable national, state, and local codes and regulations.
• Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or damage.
• The icemaker requires an independent power supply of proper capacity. See the nameplate for electrical specifications. Failure to use an independent power supply of proper capacity can result in a tripped breaker, blown fuse, damage to existing wiring, or component failure. This could lead to heat generation or fire.
• THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the icemaker could result in death or serious injury.
• To reduce the risk of electric shock, do not touch the control switch with damp hands.
• Move the control switch to the "OFF" position and turn off the power supply before servicing. Lockout/Tagout to prevent the power supply from being turned back on inadvertently.
• Do not make any alterations to the appliance. Alterations could result in electric shock, serious injury, fire, or damage.
• The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
4
WARNING, continued
• Children should be properly supervised around the appliance.
• Do not climb, stand, or hang on the appliance or allow children or animals to do so.
Serious injury could occur or the appliance could be damaged.
• Do not use combustible spray or place volatile or flammable substances near the appliance. They might catch fire.
• Keep the area around the appliance clean. Dirt, dust, or insects in the appliance could cause harm to individuals or damage to the appliance.
Additional Warning for Remote Models
• THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power supply and ground connection to the remote condenser unit are supplied from the icemaker.
Failure to properly ground the remote condenser unit could result in death or serious injury.
• Wire routing (conduit) and disconnect (if required) must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or damage.
NOTICE
• Follow the water supply, drain connection, and maintenance instructions carefully to reduce the risk of costly water damage.
• In areas where water damage is a concern, install in a contained area with a floor drain.
• Install the icemaker in a location that stays above freezing. Normal operating ambient temperature must be within 45°F to 100°F (7°C to 38°C).
• Do not leave the icemaker on during extended periods of non-use, extended absences, or in sub-freezing temperatures. To properly prepare the icemaker for these occasions, follow the instructions in "IV. Preparing the Icemaker for Periods of
Non-Use."
• Do not place objects on top of the appliance.
• The dispenser unit/ice storage bin is for ice use only. Do not store anything else in the dispenser unit/ice storage bin.
5
I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label can be seen by removing the front panel. The nameplate is located on the rear panel. For certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KM-1100M_H
Model Number
AC Supply Voltage
Compressor
KM-1100MAH
208-230/60/1
Single Phase
KM-1100MWH
208-230/60/1
KM-1100MRH
208-230/60/1
208-230V 9.0RLA 56LRA 208-230V 8.0RLA 56LRA 208-230V 8.0RLA 56LRA
Pump
Fan
120V 1.2FLA 60W 120V 1.2FLA 60W
115V 2FLA (TOTAL) 1/15HP --- --- ---
120V 1.2FLA 60W
120V 3A MAX (Fans in URC)
Other 115-120V 0.3A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
115-120V 0.3A
20 AMPS
20 AMPS
20 AMPS
115-120V 0.3A
20 AMPS
20 AMPS
20 AMPS Max. Circuit Breaker
(Canada Only)
Minimum Circuit
Ampacity
Design Pressure
Refrigerant
20 AMPS
HI-467PSI LO-230PSI
404A 3 LB. 15.4 OZ.
20 AMPS
HI-427PSI LO-230PSI
404A 1 LB. 10.5 OZ.
20 AMPS
HI-467PSI LO-230PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 9 LB. 11.2 OZ.
2. KM-1340M_H
Single Phase
Model Number KM-1340MAH
AC Supply Voltage 208-230/60/1 (3 Wire with
Neutral)
KM-1340MWH
208-230/60/1 (3 Wire with
Neutral)
Compressor
Pump
Fan
KM-1340MRH
208-230/60/1 (3 Wire with
Neutral)
208-230V 9.5RLA 61LRA 208-230V 9.2RLA 61LRA 208-230V 9.5RLA 61LRA
120V 1.2FLA 60W 120V 1.2FLA 60W
115V 2FLA (TOTAL) 60W --- --- ---
120V 1.2FLA 60W
120V 3A MAX (Fans in URC)
115-120V 0.3A
20 AMPS
20 AMPS
115-120V 0.3A 60W
20 AMPS
20 AMPS
Other 115-120V 0.3A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
20 AMPS Minimum Circuit
Ampacity
Design Pressure
Refrigerant
HI-467PSI LO-206PSI
404A 4 LB. 11.4 OZ.
20 AMPS
20 AMPS
HI-427PSI LO-230PSI
404A 2 LB. 1.5 OZ.
20 AMPS
20 AMPS
HI-467PSI LO-206PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 9 LB. 14 OZ.
6
3. KM-1601MRH/3
Model Number
Single Phase
KM-1601MRH
AC Supply Voltage 208-230/60/1 (3 Wire with
Neutral)
Compressor 230V 11.6RLA 96LRA
Pump
Fan
120V 1.2FLA 60W
120V 3A MAX (Fans in URC)
Other 115V 0.3A
Maximum Fuse Size 20 AMPS
20 AMPS Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
Design Pressure
Refrigerant
HI-467PSI LO-230PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-22F: 22 LB. 4.3 OZ.
Model Number
Three Phase
KM-1601MRH3
AC Supply Voltage 208-230/60/3
Compressor
Pump
230V 8.4RLA 75LRA
120V 1.2FLA 60W
Fan
Other
120V 3A MAX (Fans in URC)
115V 0.3A
Maximum Fuse Size 20 AMPS
20 AMPS Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
Minimum Circuit
Ampacity
Design Pressure
20 AMPS
20 AMPS
Refrigerant
HI-467PSI LO-230PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-22F: 22 LB. 4.3 OZ.
7
B. Dimensions/Connections
1. Air-Cooled Models (MAH)
Side Rear
Units: mm [in.]
Model Shown: KM-1100MAH
KM-1100MAH KM-1340MAH
A 768 [30-1/4] 768 [30-1/4]
B 762 [30]
C 602 [23-3/4]
D 827 [32-1/2]
E 786 [31]
F 775 [30-1/2]
762 [30]
602 [23-3/4]
1055 [41-1/2]
984 [38-3/4]
984 [38-3/4]
Model Shown: KM-1100MAH
Bottom
Model Shown: KM-1100MAH
NOTICE
• KM-1100MAH: Allow 12" (30 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
KM-1340_1601MAH: Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
• The ice storage bin opening must match the bottom opening as in the illustration.
8
2. Water-Cooled Models (MWH)
Side Rear
Model Shown: KM-1100MWH
KM-1100MWH KM-1340MWH
A 768 [30-1/4] 768 [30-1/4]
B 762 [30]
C 602 [23-3/4]
D 827 [32-1/2]
762 [30]
602 [23-3/4]
1055 [41-1/2]
E 750 [29-1/2]
F 775 [30-1/2]
G 390 [15-3/8]
695 [27-3/8]
984 [38-3/4]
387 [15-1/4]
NOTICE
• KM-1100MWH: Allow 12" (30 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
KM-1340_1601MWH: Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
• The ice storage bin opening must match the bottom opening as in the illustration.
9
Model Shown: KM-1100MWH
Bottom
Model Shown: KM-1100MWH
3. Remote Models (MRH/3)
Side Rear
Units: mm [in.]
Model Shown: KM-1100MRH
KM-1100MRH KM-1340MRH
KM-1601MRH/3
A 768 [30-1/4] 768 [30-1/4]
B 762 [30] 762 [30]
C 602 [23-3/4] 602 [23-3/4]
D 827 [32-1/2] 1055 [41-1/2]
E 750 [29-1/2] 975 [38-3/8]
F 775 [30-1/2] 984 [38-3/4]
G 457 [18] 454 [17-7/8]
H 76 [3]
I 110 [4-3/8]
101 [4]
82 [3-1/4]
NOTICE
• KM-1100MRH: Allow 12" (30 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
KM-1340_1601MRH/3: Allow 6"
(15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
• The ice storage bin opening must match the bottom opening as in the illustration.
10
Model Shown: KM-1100MRH
Bottom
Model Shown: KM-1100MRH
4. Remote Condenser Unit URC-14F (use with KM-1100MRH and KM-1340MRH)
Units: mm [in.]
NOTICE
Allow 24" (61 cm) clearance at front and rear for proper air circulation and ease of maintenance and/or service should they be required.
Top
Rear
Icemaker
Model
URC-14F Heat of Rejection
AT 90°F (32°C)
WT 70°F (21°C)
KM-1100MRH TBD BTU/hr
KM-1340MRH 20,800 BTU/hr
5. Remote Condenser Unit URC-22F (use with KM-1601MRH/3)
NOTICE
Allow 24" (61 cm) clearance at front and rear for proper air circulation and ease of maintenance and/or service should they be required.
Top
Units: mm [in.]
Icemaker
Model
URC-22F Heat of Rejection
AT 90°F (32°C)
WT 70°F (21°C)
KM-1601MRH 27,400 BTU/hr
KM-1601MRH3 24,300 BTU/hr
Rear
11
II. Installation and Operating Instructions
WARNING
• The appliance must be installed in accordance with applicable national, state, and local codes and regulations.
• Failure to install, operate, and maintain the appliance in accordance with this manual will adversely affect safety, performance, component life, and warranty coverage and may result in costly water damage.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/ice storage bin.
A. Location
NOTICE
• The icemaker is not intended for outdoor use. Normal operating ambient temperature must be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature must be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance.
• The icemaker will not work at sub-freezing temperatures. To prevent damage to the water supply line, drain the icemaker if the air temperature is going to go below 32°F (0°C). See "IV. Preparing the Icemaker for Periods of Non-Use."
• The icemaker should not be located next to ovens, grills, or other high heat producing equipment.
• For KM-1100M_H models, allow 12" (30 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
For KM-1340M_H and KM-1601M_H/3 models, allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.
• The location should provide a firm and level foundation for the appliance.
B. Checks Before Installation
• Visually inspect the exterior of the shipping container and immediately report any damage to the carrier. Upon opening the container, any concealed damage should also be immediately reported to the carrier.
• Remove the shipping carton, tape, and packing material. If any are left in the appliance, it will not work properly.
• See the nameplate on the rear panel, and check that your voltage supplied corresponds with the voltage specified on the nameplate.
• Remove the panels to prevent damage when installing the appliance. See "II.C. How to
Remove Panels."
12
• Remove the package containing the accessories.
• Remove the protective plastic film from the panels. If the appliance is exposed to the sun or to heat, remove the film after the appliance cools.
• Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blade (if applicable) turns freely.
• Check that the compressor is snug on all mounting pads.
• The icemaker can be installed on a dispenser unit or ice storage bin. The ice storage bins listed below are recommended.
Model Number Bin Width Recommended Hoshizaki Ice Storage Bin
KM-1100M_H
KM-1340M_H
KM-1601MRH/3
30" or Wider B-500 Series
For further options, contact your local Hoshizaki distributor.
• NOTICE! Remote models must be connected to an appropriate remote condenser unit. The remote condenser units listed below are recommended. Connection to a different remote condenser unit will void the warranty unless Hoshizaki approves a different remote condenser unit for your specific application. For further details, contact your local Hoshizaki distributor.
Model Number Recommended Hoshizaki Remote Condenser Unit
KM-1100MRH URC-14F
KM-1340MRH
KM-1601MRH/3 URC-22F
C. How to Remove Panels
See Fig. 1
• Front Panel: Remove the screw. Lift up and pull towards you.
• Top Panel: Lift up at front slightly, push rearward and lift off.
• Right Side Panel: Remove the screw. Slide forward slightly and lift off.
• Insulation Panel: Lift up slightly, and pull towards you.
Insulation Panel
Front
Panel
Top Panel
Right
Side
Panel
Fig. 1
13
D. Setup
1. Dispenser Unit/Ice Storage Bin and Icemaker Setup
WARNING
The installer must ensure the dispenser unit/ice storage bin is compatible with the icemaker, and the dispenser unit/ice storage bin and icemaker are properly attached and secured.
1a) Dispenser Unit: Follow the dispenser unit's setup procedure.
1b) Ice Storage Bin: Unpack the ice storage bin and attach the 4 adjustable legs provided
(bin accessory) to the bottom of the ice storage bin.
2) Position the dispenser unit/ice storage bin in its permanent location.
3) If required, install an adapter kit or top kit. Contact your local Hoshizaki distributor for recommendations.
4) Level the dispenser unit/ice storage bin in both the left-to-right and front-to-rear directions. If using an ice storage bin, adjust the ice storage bin legs to level.
5) Place the icemaker on top of the dispenser unit/ice storage bin.
6a) Dispenser Unit: Follow the dispenser unit, adapter kit, or top kit instructions for securing the icemaker. If no instructions are available, secure the icemaker using the mounting brackets provided. Rotate the mounting brackets so that they fit flush to the dispenser unit. See Fig. 2a. Secure the mounting brackets to the icemaker with the bolts provided. Secure the mounting brackets to the dispenser unit with self-tapping screws
(not provided). NOTICE! Use care to avoid damage to dispenser unit components when attaching the mounting brackets.
6b) Ice Storage Bin: Follow the ice storage bin, adapter kit, or top kit instructions for securing the icemaker. If no instructions are available, secure the icemaker using the
2 mounting brackets and the bolts provided. See Fig. 2b.
Icemaker Icemaker
Mounting
Brackets
Bolts
Fig. 2a
Bolts
Fig. 2b
Self-Tapping
Screws
(Not Provided)
Dispenser
Unit
Model Shown: KM-1340MWH
Ice
Storage
Bin
Mounting
Brackets
14
2. Bin Control Installation
NOTICE
Before operating the icemaker, the bin control must be installed. Failure to properly install the bin control could result in ice backup and icemaker damage.
1) Install the bin control thermostat assembly as follows. See Fig. 3.
a. Remove the bin control thermostat assembly from the shipping hook.
b. Remove the 2 thumbscrews below the bin control thermostat assembly. c. Lower the bin control thermostat assembly through the hole located in the bottom of the icemaker. Secure the bin control thermostat assembly with the lower hook and the 2 thumbscrews removed in the previous step.
d. Insert the plug into the receptacle on the assembly until it locks into place.
IMPORTANT! The plug must be inserted into the receptacle for the icemaker to operate.
2) Replace the panels in their correct positions.
Shipping Hook
Bin Control
Thermostat
Assembly
Plug
Receptacle
Lower Hook
Thumbscrews
Hole
Thumbscrews
Hole
Fig. 3
15
E. Electrical Connection
WARNING
For All Models
• Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or damage.
• The icemaker requires an independent power supply of proper capacity. See the nameplate for electrical specifications. Failure to use an independent power supply of proper capacity can result in a tripped breaker, blown fuse, damage to existing wiring, or component failure. This could lead to heat generation or fire.
• THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the icemaker could result in death or serious injury.
• Electrical connection must be made in accordance with the instructions on the
"WARNING" tag, provided with the pig tail leads in the junction box. See Fig. 4.
Additional Warnings for Remote Models
• THE REMOTE CONDENSER UNIT MUST BE GROUNDED. Power supply and ground connection to the remote condenser unit are supplied from the icemaker.
See "II.G.6. Electrical Connection." Failure to properly ground the remote condenser unit could result in death or serious injury.
• To reduce the risk of electric shock, make all remote condenser unit connections before connecting the icemaker power supply.
NOTICE
On remote models, the appliance must have power for a minimum of 4 hours prior to startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• NOTICE! On single phase KM-1100M_H models, the main transformer’s voltage tap switch must be positioned to match incoming voltage at startup.
• NOTICE! On single phase KM-1340M_H and KM-1601M_H models, the white lead must be connected to the neutral conductor of the power source. Miswiring may result in severe damage to the icemaker.
• NOTICE! On three phase models, the main transformer’s voltage tap switch must be positioned to match incoming voltage at startup.
• NOTICE! On three phase models, connect the highest incoming voltage supply
("stinger leg") to the power wire dedicated to the compressor. See the wiring label on the icemaker.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
16
KM-1100M_H
KM-1340M_H
KM-1601MRH
KM-1601MRH3
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire this unit could result in death, serious injury, or severe damage to the icemaker.
This unit must be connected to a three-phase power source.
The transformer’s voltage tap switch must be positioned to match incoming voltage at startup.
See diagram below.
208-230/60/3
JUNCTION BOX
L1
BROWN
208- 230V
L2
RED
208- 230V
L3
BLACK
4A4807-010
Fig. 4
17
F. Water Supply and Drain Connections
See Figs. 5 through 7
WARNING
Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations.
NOTICE
• Normal operating water temperature should be within 45°F to 90°F (7°C to
32°C). Operation of the appliance, for extended periods, outside of this normal temperature range may affect appliance performance.
• Water supply pressure must be a minimum of 10 PSIG and a maximum of
113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• To prevent damage to the appliance, do not operate the appliance when the water supply is off, or if the pressure is below 10 PSIG. Do not run the appliance until the proper water pressure is reached.
• External filters, strainers, or softeners may be required depending on water quality.
Contact your local Hoshizaki Certified Service Representative or local Hoshizaki distributor for recommendations.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• The icemaker drain line, dispenser unit/ice storage bin drain line, and water-cooled condenser drain line (if applicable) must be run separately. The condensation drain line can be connected to the icemaker drain line or can be run separately.
• Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good flow. A vented tee connection is also required for proper flow.
• Drain lines should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker and condensation drain, dispenser unit/ice storage bin, and water-cooled condenser (if applicable) and the floor drain.
18
1. Icemaker
Icemaker Water
Supply Inlet
1/2" Female Pipe
Thread (FPT)
Minimum Icemaker
Water Supply Line Size
3/8" Nominal ID
Copper Water Tubing or
Equivalent
Icemaker Drain
Outlet
3/4" Female Pipe
Thread (FPT)
Minimum Icemaker
Drain Line Size
3/4" Nominal
ID Hard Pipe or
Equivalent
Condensation
Drain Outlet
3/8" OD Hard
Tube
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be pulled out for service.
Icemaker Water Supply Inlet
1/2" FPT
Remote Condenser
Line Set Connections
Icemaker
Minimum 3/8" Nominal ID Copper
Water Tubing or Equivalent
Shut-Off Valve
Drain Valve
Icemaker
Drain Outlet
3/4" FPT
Icemaker
Condensation
Drain Outlet
3/8" OD Hard
Tube
Bin Drain Outlet
3/4" FPT
Ice
Storage
Bin
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Vent Tube
Be sure there is sufficient extra water supply line and drain line for the appliance to be pulled out for service.
Separate piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of each pipe and the drain.
2-inch (5-cm) air gap
Floor Drain
Fig. 5
Model Shown:
KM-1601MRH
Air-Cooled and Remote Models
19
2. Water-Cooled Condenser a) Connection to an Open Drain System
Condenser Water
Supply Inlet
1/2" Female Pipe
Thread (FPT)
Minimum Condenser
Water Supply Line Size
3/8" Nominal ID Copper
Water Tubing or Equivalent
Condenser Drain
Outlet
Minimum Condenser
Drain Line Size
3/8" Female Pipe
Thread (FPT)
3/8" Nominal ID Hard Pipe or Equivalent
• A condenser water supply line shut-off valve and drain valve must be installed.
• In some areas, a back flow preventer may be required in the cooling water circuit.
• In order to maintain the proper high side pressure, the condenser water supply inlet temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation is complete, confirm the condenser drain outlet temperature 5 minutes after a freeze cycle starts. If the condenser drain outlet temperature is not in the proper range, use a flat blade screwdriver to rotate the adjustment screw on the water-regulating valve until the temperature is in the proper range (rotate counterclockwise to raise temperature or clockwise to lower temperature).
Icemaker Water
Supply Inlet
1/2" FPT
Condenser Water
Supply Inlet
1/2" FPT
Vent Tube
Icemaker
Minimum 3/8" Nominal ID Copper
Water Tubing or Equivalent
Shut-Off Valve
Condenser
Drain Outlet
3/8" FPT
Icemaker
Drain Outlet
3/4" FPT
Bin Drain Outlet
3/4" FPT
Minimum 3/8"
Nominal ID
Hard Pipe or
Equivalent
Ice
Storage
Bin
Minimum 3/8" Nominal ID Copper
Water Tubing or Equivalent
Drain Valve
Icemaker
Condensation
Drain Outlet
3/8" OD Hard Tube
Vent Tube
Be sure there is sufficient extra water supply line and drain line for the appliance to be pulled out for service.
Separate piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of each pipe and the drain.
2-inch (5-cm) air gap
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Fig. 6
Model Shown:
KM-1340MWH
Water-Cooled Models
Connection to an Open Drain System
20
Floor Drain
b) Connection to a Closed Loop System
Condenser Water
Supply Inlet
1/2" Female Pipe
Thread (FPT)
Minimum Condenser
Water Supply Line Size
3/8" Nominal ID Copper
Water Tubing or Equivalent
Condenser
Return Outlet
3/8" Female Pipe
Thread (FPT)
Minimum Condenser
Return Line Size
3/8" Nominal ID Copper
Water Tubing or Equivalent
• Shut-off valves and drain valves must be installed at both the condenser water supply inlet and condenser return outlet.
• Minimum water flow to the condenser is 4 GPM.
• The pressure differential between the condenser water supply inlet and condenser return outlet must be no less than 10 PSIG.
• When using a glycol blend, the solution mixture should be less than 30% glycol.
• In order to maintain the proper high side pressure, the condenser water supply inlet temperature should not drop below 45°F (7°C) and the condenser return outlet temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation is complete, confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts. If the condenser return outlet temperature is not in the proper range, use a flat blade screwdriver to rotate the adjustment screw on the water-regulating valve until the temperature is in the proper range (rotate counterclockwise to raise temperature or clockwise to lower temperature).
Minimum 3/8" Nominal ID Copper
Water Tubing or Equivalent
Icemaker Water
Supply Inlet
1/2" FPT
Icemaker
Shut-Off Valve
Condenser Water
Supply Inlet
1/2" FPT
Condenser
Return Outlet
3/8" FPT
Vent Tube
Icemaker
Drain Outlet
3/4" FPT
Icemaker
Condensation
Drain Outlet
3/8" OD Hard
Tube
Ice
Storage
Bin
Drain Valve
Be sure there is sufficient extra water supply line and drain line for the appliance to be pulled out for service.
Separate piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of each pipe and the drain.
Bin Drain Outlet
3/4" FPT
Vent Tube
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Fig. 7
Model Shown:
KM-1340MWH
Water-Cooled Models
Connection to a Closed Loop System
21
2-inch (5-cm) air gap
Floor Drain
G. Installation of Remote Condenser Unit
WARNING
• Installation of remote condenser unit must be performed by properly trained and
EPA-certified service personnel.
• The remote condenser unit must be installed in accordance with applicable national, state, and local codes and regulations.
• Failure to install the remote condenser unit within these guidelines may adversely affect safety, performance, component life, and warranty coverage.
• Power supply and ground wire to the remote condenser unit are supplied from the icemaker. For details, see section "II.G.6. Electrical Connection."
1. Location
NOTICE
• The remote condenser unit is intended for outdoor use. Normal operating ambient temperature must be within -20°F to +122°F (-29°C to +50°C). Operation of the remote condenser unit, for extended periods, outside of this normal temperature range may affect appliance performance.
• The maximum line length for the standard line sizes and refrigerant charge is
66' (20 m). With larger line sizes and/or additional refrigerant, the maximum line length is 100' (30.5 m). For details, see "II.G.4 Line Set Size and Refrigerant
Charge."
• The maximum vertical distance between the remote condenser unit and the icemaker is 33' (10 m) above or 10' (3 m) below the icemaker. These distances are measured fitting to fitting. See Fig. 8.
The remote condenser unit must be positioned in a permanent site under the following guidelines:
• A firm and flat site.
• A dry and well ventilated area with 24" (61 cm) clearance at front and rear for proper air circulation and ease of maintenance and/or service should they be required. See Fig. 9.
Icemaker
Remote
Condenser
Unit
Min. 24" (61 cm) Clearance
Max.
33'
(10 m)
Icemaker
Max.
10'
(3 m)
Air Air
Service Loop
Fig. 9
Service Loop
Fig. 8
Remote
Condenser
Unit
22
2. Checks Before Installation
1) Remove the shipping carton, tape, and packing material.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blades move freely.
3. Setup
1) Assemble 2 sets of legs using the legs, bolts, and nuts provided. See Fig. 10.
2) Position 1 of the plates provided between a set of legs and the remote condenser unit, then secure the legs to the remote condenser unit with the bolts and nuts provided. Repeat on the other side with the remaining set of legs.
3) The bottom of each leg has a mounting hole.
Secure the legs to the permanent site with 4 bolts
(not included).
4. Line Set Size and Refrigerant Charge
Plate
Nut
Leg
Bolt with Split
Lock Washer and
Flat Washer
Fig. 10
Nut
NOTICE
The icemaker, line set, and remote condenser unit must contain the same type of refrigerant. Mixing of refrigerants will result in improper operation and possible damage to the refrigeration system.
Hoshizaki
Icemaker
KM-1100MRH
KM-1340MRH
Hoshizaki
Remote
Condenser
Unit
Line Set Size and Refrigerant Charge
Line Set
Up to 66' (20 m)
Liquid
Line
URC-14F 3/8"
OD
Discharge
Line
1/2" OD
Charge
Adjustment
Not
Applicable
Line Set
Greater than 66' (20 m)
Maximum 100' (30.5 m)
Liquid
Line
3/8"
OD
Discharge
Line
1/2" OD
Charge Adjustment
(R-404A)
Add 0.4 oz. for each foot over 66' (40 g for each meter over
20 m). Write new total charge on icemaker's rating label.
KM-1601MRH/3 URC-22F 3/8"
OD
5/8" OD Not
Applicable
3/8"
OD
5/8" OD Add 0.4 oz. for each foot over 66' (40 g for each meter over
20 m). Write new total charge on icemaker's rating label.
23
5. Line Set Installation
Precharged factory line sets, available as optional equipment from Hoshizaki America, are recommended. For details, see "II.G.5.a) Factory Line Set Installation." Field fabricated line sets are allowed. For details, see "II.G.5.b) Field Fabricated Line Set
Installation." a) Factory Line Set Installation
1) Route the factory line set (see "II.G.4 Line Set Size and Refrigerant Charge" for details) from the remote condenser unit to the icemaker. Leave a service loop behind the icemaker to allow the icemaker to be pulled out for service. See Fig. 11. Factory fabricated line sets are precharged and do not need to be evacuated. If the line set is too long or too short, see "II.G.5.a)(1) Factory Line Set Modification."
NOTICE
• Ensure that there are no traps and no kinks in the line set. The service loop is not considered an oil trap.
• Do not coil extra line set.
2) Connect the refrigerant lines to the appropriate male fittings on the remote condenser unit first and then at the icemaker. Make a proper connection as follows: a. Remove the protective covers from the male fitting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil or Parker Super O Lube to the entire male fitting, including O-ring, diaphragm, and threads before making the connection.
See Fig. 12. NOTICE! Do not use thread sealant on the fittings. Use POE refrigerant oil or Parker Super O Lube only. Couplings are one-time use only.
c. Make sure the male fitting and female coupling are properly aligned, then start the connection by hand to ensure that it is not cross threaded. d. Place a backup wrench on the back of the female coupling, then tighten the connection with a wrench until it is tight. At this point, the nut has covered most of the threads on the male fitting. NOTICE! Failure to use a backup wrench may result in damage to the line set and possible refrigerant leaks.
e. Mark a reference line on the female coupling and the remote condenser unit or icemaker panel. Using a backup wrench on the back of the female coupling, tighten the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 13.
NOTICE! Confirm connection is free of leaks.
3) If you lengthened the line set as outlined in "II.G.5.a)(1) Factory Line Set Modification" and it exceeds 66' (20 m), see "II.G.4. Line Set Size and Refrigerant Charge" for proper charging of the appliance.
24
(1) Factory Line Set Modification
1) Recover the line set charge through the Schrader access ports on the Parker quick connect couplings and store it in an approved container. Do not discharge the refrigerant into the atmosphere. Remove the extra line set length or add extra tubing.
When adding extra tubing, insulate the additional copper tubes separately.
2) Use an electronic leak detector or soap bubbles to check for leaks. Add a trace of refrigerant to the lines through the Schrader access ports on the Parker quick connect couplings (if using an electronic leak detector), and then raise the pressure using nitrogen gas (140 PSIG). WARNING! Do not use R-404A as a mixture with pressurized air for leak testing.
3) Evacuate through the Schrader access ports on the Parker quick connect couplings and charge with R-404A refrigerant vapor to a pressure of 15 to 30 PSIG. Go to step 2 in
"II.G.5.a) Factory Line Set Installation." b) Field Fabricated Line Set Installation
1) Route the copper tube liquid line and copper tube discharge line (see "II.G.4 Line
Set Size and Refrigerant Charge" for details) from the remote condenser unit to the icemaker. Leave a service loop behind the icemaker to allow the icemaker to be pulled out for service. See Fig. 11.
NOTICE
• Ensure that there are no traps and no kinks in the line set. The service loop is not considered an oil trap.
• Do not coil extra line set. Fabricate the line set to the proper length.
2) Insulate the two copper tubes separately.
3) Install Parker quick connect couplings on each end. OS-QUICK, a universal quick connect coupling kit available as optional equipment from Hoshizaki America, is recommended. NOTICE! Before brazing, remove the Schrader valve core from the access port. When brazing, protect the coupling by using a wet cloth to prevent the coupling from overheating. Do not use silver alloy or copper alloy containing arsenic.
4) Allow the coupling to cool, then replace the Schrader valve core.
5) Use an electronic leak detector or soap bubbles to check for leaks. Add a trace of refrigerant to the lines through the Schrader access ports on the Parker quick connect couplings (if using an electronic leak detector), and then raise the pressure using nitrogen gas (140 PSIG). WARNING! Do not use R-404A as a mixture with pressurized air for leak testing.
6) Evacuate through the Schrader access ports on the Parker quick connect couplings and charge with R-404A refrigerant vapor to a pressure of 15 to 30 PSIG.
25
7) Connect the refrigerant lines to the appropriate male fittings on the remote condenser unit first and then at the icemaker. Make a proper connection as follows: a. Remove the protective covers from the male fitting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil or Parker Super O Lube to the entire male fitting, including O-ring, diaphragm, and threads, before making the connection.
See Fig. 12. NOTICE! Do not use thread sealant on the fittings. Use POE refrigerant oil or Parker Super O Lube only. Couplings are one-time use only.
c. Make sure the male fitting and female coupling are properly aligned, then start the connection by hand to ensure that it is not cross threaded. d. Place a backup wrench on the back of the female coupling, then tighten the connection with a wrench until it is tight. At this point, the nut has covered most of the threads on the male fitting. NOTICE! Failure to use a backup wrench may result in damage to the line set and possible refrigerant leaks.
e. Mark a reference line on the female coupling and the remote condenser unit or icemaker panel. Using a backup wrench on the back of the female coupling, tighten the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 13.
NOTICE! Confirm connection is free of leaks.
8) If the line set exceeds 66' (20 m), see "II.G.4. Line Set Size and Refrigerant Charge" for proper charging of the appliance.
Fig. 11
Fig. 12
Fig. 13
Remote Condenser Unit
Icemaker
Male Fitting
Female Coupling
Discharge Line (Insulated)
See "II.G.4 Line Set Size and
Refrigerant Charge" for details.
Liquid Line (Insulated)
See "II.G.4 Line Set Size and
Refrigerant Charge" for details.
Service Loop
Male Fitting
Brush
Threads
Diaphragm
Apply POE Oil or
Parker Super O Lube to Entire Male Fitting
O-Ring
DO NOT USE
THREAD SEALANT
Reference
Line
Wrench 1/6
Turn
After Tight, Tighten an
Additional 1/6 Turn
Backup
Wrench
Backup
Wrench
Wrench
26
6. Electrical Connection
WARNING
• Electrical connection must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or damage.
• To reduce the risk of electric shock, make all remote condenser unit connections before connecting the icemaker power supply.
• THE REMOTE CONDENSER UNIT MUST BE GROUNDED. Install a ground wire from the icemaker fan motor junction box to the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating. Failure to properly ground the remote condenser unit could result in death or serious injury.
• Install line and neutral wires from the fan motor leads in the icemaker fan motor junction box to the leads in the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating.
• Do not connect the fan motor leads in the icemaker to incoming power source. Do not connect the fan motor leads in the icemaker together. Do not allow the leads to contact the junction box walls.
• Do not connect the remote condenser unit to an external power source.
NOTICE
On remote models, the appliance must have power for a minimum of 4 hours prior to startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
1) Remove the remote condenser unit louver panel. See Fig. 14.
2) Remove the icemaker fan motor junction box cover. Remove the remote condenser unit junction box cover.
Remote Condenser Unit Icemaker
Screws
Louver Panel
Fan Motor Junction
Box Cover
Fig. 14
Junction Box Cover
Screw
27
3) Install a ground wire from the icemaker fan motor junction box to the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating.
4) Install line and neutral wires from the fan motor leads in the icemaker fan motor junction box to the leads in the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating.
5) Replace the junction box covers and the louver panel in their correct positions.
7. Stacking Remote Condenser Unit
1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower remote condenser unit. See
Fig. 15.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the
4 screws provided.
4) Install refrigerant lines and make electrical connection as described earlier in this section.
Upper Remote
Condenser Unit
Screws Screws
Lower Remote
Condenser Unit
Fig. 15
28
H. Final Checklist
WARNING
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/ice storage bin.
1) Is the icemaker level?
2) Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to
38°C) and the water temperature within 45°F to 90°F (7°C to 32°C) all year around?
3) For KM-1100M_H models, is there at least 12" (30 cm) clearance at rear, sides, and top of the icemaker.
For KM-1340M_H and KM-1601M_H/3 models, is there at least 6" (15 cm) clearance at rear, sides, and top of the icemaker.
4) Have the shipping carton, tape, and packing material been removed from the appliance? Is the cube guide in the correct position? Are the separators between the evaporator banks properly attached to their holding clips?
5) Have all electrical and water connections been made? Do electrical and water connections meet applicable national, state, and local code and regulation requirements?
6) Has the power supply voltage been checked or tested against the nameplate rating?
Has a proper ground been installed to the icemaker? On remote models, has a proper ground also been installed to the remote condenser unit?
7) Are the water supply and drain lines sized as specified? Are the water supply line shut-off valve(s) and drain valve(s) installed? Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG?
8) Is the compressor snug on all mounting pads? Have the refrigerant lines been checked to make sure they do not rub or touch other lines or surfaces? Have the fan blades (if applicable) been checked to make sure they turn freely?
9) On remote models:
• Is the line set sized as specified, insulated, tightened, and free of leaks and kinks?
• If the line set exceeds 66' (20 m), has the charge been adjusted as specified?
• Has the appliance power supply been on for a minimum of 4 hours?
• Is the remote condenser unit in a site where the ambient temperature is within
-20°F to +122°F (-29°C to +50°C) all year around?
• Is there at least 24" (61 cm) clearance around the remote condenser unit?
10) Are all components, fasteners, and thumbscrews securely in place?
11) Has the end user been given the instruction manual, and instructed on how to operate the appliance and the importance of the recommended periodic maintenance?
12) Has the end user been given the contact information of an authorized service agent?
13) Has the warranty card been filled out and forwarded to the factory for warranty registration?
29
I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage.
NOTICE
• If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
• To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
• At startup, confirm that all internal and external connections are free of leaks.
Additional Notice for Remote Models
• The icemaker must have power for a minimum of 4 hours prior to startup to prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply and allow the icemaker to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel and the insulation panel.
7) Slide the cube guide to the right, then remove the rubber cap and sleeve covering the overflow pipe. See Fig. 16. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, and cube guide in their correct positions. NOTICE! Make sure the O-ring is attached to the bottom of the overflow pipe and be careful not to cross thread the overflow pipe.
8) Replace the insulation panel and the front panel in their correct positions.
9) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
10) Turn on the power supply to start the automatic icemaking process.
11) When the icemaker is running, hold an ice cube in contact with the bulb. The icemaker should stop within
10 seconds. Adjustment may be needed, particularly at higher altitude locations.
12) On water-cooled models, confirm proper condenser drain outlet/return outlet temperature as outlined in
"II.F.2. Water-Cooled Condenser."
Cube Guide
Rubber Cap
Sleeve
Overflow Pipe
O-Ring
Fig. 16
30
III. Maintenance
The appliance must be maintained in accordance with the instruction manual and labels provided. Consult with your local Hoshizaki Certified Service Representative about maintenance service.
WARNING
• Only qualified service technicians should service the appliance.
• To reduce the risk of electric shock, do not touch the control switch with damp hands.
• Move the control switch to the "OFF" position and turn off the power supply before servicing. Lockout/Tagout to prevent the power supply from being turned back on inadvertently.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any maintenance is done to the appliance. Make sure that none have fallen into the dispenser unit/ice storage bin.
A. Maintenance Schedule
The maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the appliance's environment, and local sanitation regulations.
Frequency Area
Daily Scoop
Bi-Weekly Air Filters
Monthly External Water
Filters
Maintenance Schedule
Task
Clean the ice scoop using a neutral cleaner. Rinse thoroughly after cleaning.
Inspect. Wash with warm water and neutral cleaner if dirty.
Check for proper pressure and change if necessary.
Yearly
Icemaker Exterior Wipe down with a clean, soft cloth. Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build up. Clean any chlorine staining (rust colored spots) using a non-abrasive cleanser.
Underside of
Icemaker and Top
Kits; Bin Door
Wipe down with a clean cloth and warm water.
Icemaker and
Dispenser Unit/Ice
Storage Bin
Clean and sanitize per the cleaning and sanitizing instructions provided in this manual. See "III.B. Cleaning and Sanitizing Instructions."
Water Supply Inlet Close the icemaker water supply line shut-off valve and drain the water system. Clean the water supply inlet screen.
Condenser Inspect. Clean if necessary by using a brush or vacuum cleaner. More frequent cleaning may be required depending on location.
Water Hoses Inspect the water hoses and clean/replace if necessary.
31
B. Cleaning and Sanitizing Instructions
The icemaker must be cleaned and sanitized at least once a year. More frequent cleaning and sanitizing may be required in some water conditions.
WARNING
• To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.
• Carefully follow any instructions provided with the bottles of cleaning and sanitizing solution.
• Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing solutions from coming into contact with skin or eyes.
• Do not leave the icemaker unattended when panels are off.
NOTICE
To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
IMPORTANT
• The cleaning valve is opened during cleaning and sanitizing to allow solution flow to the inside of the evaporator. It should be closed for all icemaking operation. The compressor will not operate unless this valve is completely closed.
• To close the cleaning valve, the valve handle should be at a right angle to the valve body. To open the cleaning valve, the valve handle should be parallel to the valve body.
CLOSED
Icemaking Operation
OPEN
Cleaning and Sanitizing Operation
(allows solution flow to the inside of the evaporator)
Preparation
1) Remove the front panel, then move the control switch to the "OFF" position.
After 3 min., move the control switch to the "ICE" position, then replace the front panel.
2) After 3 min., remove the front panel, then move the control switch to the "OFF" position.
3) Remove all ice from the dispenser unit/ice storage bin. WARNING! If on a dispenser unit, turn off the dispenser unit power supply after dispensing the ice.
32
Cleaning
4) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. See Fig. 16. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel. NOTICE! Make sure the O-ring is attached to the bottom of the overflow pipe and be careful not to cross thread the overflow pipe.
5) To fill the water tank, move the control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the front panel, then move the control switch to the "OFF" position.
6) Remove the front insulation panel, then pour 30 fl. oz. (887 ml) of Hoshizaki "Scale
Away" into the water tank. Replace the front insulation panel. Turn the cleaning valve to the left until completely vertical (open).
7) NOTICE! To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front panel.
8) After 30 min., remove the front panel, then move the control switch to the "OFF" position.
9) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel.
10) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and replace the cube guides, float switch, water supply tubes, spray tubes, and spray guides; turn on the power supply when complete. Otherwise, continue to step 11..
Cleaning Rinse
11) Turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the front panel, then move the control switch to the "OFF" position. Note: The icemaker will not operate unless the cleaning valve is completely closed.
12) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to the "WASH" position, then replace the front panel. After 5 min., remove the front panel, then move the control switch to the "OFF" position.
13) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel.
33
Sanitizing
14) To fill the water tank, turn the cleaning valve to the right until completely horizontal
(closed). Move the control switch to the "ICE" position, then replace the front panel. After
3.5 min., remove the front panel, then move the control switch to the "OFF" position.
15) Remove the front insulation panel, then pour 1.7 fl. oz. (50 ml) of an 8.25% sodium hypochlorite solution (chlorine bleach) into the water tank. Replace the front insulation panel. Turn the cleaning valve to the left until completely vertical (open). IMPORTANT!
Use regular bleach with no additives. Using a bleach with additives causes excessive foaming during sanitizing, reducing the effectiveness of sanitizing.
16) NOTICE! To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front panel.
17) After 45 min., remove the front panel, then move the control switch to the "OFF" position.
18) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel.
Sanitizing Rinse 1
19) Turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the front panel, then move the control switch to the "OFF" position.
20) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to the "WASH" position, then replace the front panel. After 5 min., remove the front panel, then move the control switch to the "OFF" position.
21) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel.
Sanitizing Rinse 2
22) Turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the front panel, then move the control switch to the "OFF" position.
23) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to the "WASH" position, then replace the front panel. After 5 min., remove the front panel, then move the control switch to the "OFF" position.
24) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel.
34
Sanitizing Rinse 3
25) Turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the front panel, then move the control switch to the "OFF" position.
26) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to the "WASH" position, then replace the front panel. After 5 min., remove the front panel, then move the control switch to the "OFF" position.
27) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, cube guide, and front insulation panel. NOTICE! Be sure the O-ring is attached to the bottom of the overflow pipe and be careful not to cross thread the overflow pipe.
28) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
29) Turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position. Note: If on a dispenser unit, turn on the dispenser unit power supply.
30) Replace all panels in their correct positions.
35
IV. Preparing the Icemaker for Periods of Non-Use
NOTICE
• When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage.
• To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
When the icemaker is not used for two or three days under normal conditions, it is sufficient to move the control switch to the "OFF" position. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below.
1. Remove the water from the icemaker water supply line:
1) Turn off the power supply, then remove the front panel.
2) Move the control switch to the "OFF" position.
3) Close the icemaker water supply line shut-off valve, then open the icemaker water supply line drain valve.
4) Allow the line to drain by gravity.
5) Attach a compressed air or carbon dioxide supply to the icemaker water supply line drain valve.
6) Move the control switch to the "ICE" position.
7) Replace the front panel in its correct position, then turn on the power supply.
8) Blow the icemaker water supply line out using the compressed air or carbon dioxide supply.
9) Close the icemaker water supply line drain valve.
2. Drain the water tank:
1) Turn off the power supply, then remove the front panel. Move the control switch to the
"OFF" position.
2) Remove the insulation panel.
3) Slide the cube guide to the right, then remove the rubber cap and sleeve covering the overflow pipe. See Fig. 16. Unscrew the overflow pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve, and cube guide in their correct positions. NOTICE! Make sure the O-ring is attached to the bottom of the overflow pipe and be careful not to cross thread the overflow pipe.
4) Replace the insulation panel in its correct position.
5) Remove all ice from the storage bin. Clean the storage bin using a neutral cleaner.
Rinse thoroughly after cleaning.
6) Replace the front panel in its correct position.
36
3. On water-cooled model only, first remove the water from the water-cooled condenser:
1) Make sure the power supply is off, then remove the front, top, and right side panels.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop system, also close the condenser return line shut-off valve.
3) Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve.
4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.
5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow out the condenser using the compressed air or carbon dioxide supply until water stops coming out.
6) Close the drain valve(s).
7) Replace the right side panel, top panel, and front panel in their correct positions.
37
V. Disposal
The appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulations. Refrigerant must be recovered by properly certified service personnel.
38
HOSHIZAKI AMERICA, INC.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Important Safety Information
- 6 I. Specifications
- 6 A. Electrical and Refrigerant Data
- 6 1. KM-1100M_H
- 6 2. KM-1340M_H
- 7 3. KM-1601MRH/3
- 8 B. Dimensions/Connections
- 8 1. Air-Cooled Models (MAH)
- 9 2. Water-Cooled Models (MWH)
- 10 3. Remote Models (MRH/3)
- 11 4. Remote Condenser Unit URC-14F (use with KM-1100MRH and KM-1340MRH)
- 11 5. Remote Condenser Unit URC-22F (use with KM-1601MRH/3)
- 12 II. Installation and Operating Instructions
- 12 A. Location
- 12 B. Checks Before Installation
- 13 C. How to Remove Panels
- 14 D. Setup
- 14 1. Dispenser Unit/Ice Storage Bin and Icemaker Setup
- 15 2. Bin Control Installation
- 16 E. Electrical Connection
- 18 F. Water Supply and Drain Connections
- 19 1. Icemaker
- 20 2. Water-Cooled Condenser
- 22 G. Installation of Remote Condenser Unit
- 22 1. Location
- 23 2. Checks Before Installation
- 23 3. Setup
- 23 4. Line Set Size and Refrigerant Charge
- 24 5. Line Set Installation
- 27 6. Electrical Connection
- 28 7. Stacking Remote Condenser Unit
- 29 H. Final Checklist
- 30 I. Startup
- 31 III. Maintenance
- 31 A. Maintenance Schedule
- 32 B. Cleaning and Sanitizing Instructions
- 36 IV. Preparing the Icemaker for Periods of Non-Use
- 38 V. Disposal