fi-5000N Firmware Updating Procedure 1. Preparation before Updating the Firmware

fi-5000N Firmware Updating Procedure 1. Preparation before Updating the Firmware
fi-5000N Firmware Updating Procedure
1. Preparation before Updating the Firmware
1)
2)
Before updating the firmware, connect the fi-5000N to the PC (where the Firmware Update Tool is to
be installed) via a network.
If a USB cable is connected to the fi-5000N, disconnect it from the fi-5000N.
Note
● Configure the IP addresses of the PC and the fi-5000N within the same subnet.
Example of Network Settings for PC and fi-5000N
Device
PC
fi-5000N
IP Address / Subnet Mask
123.123.123.xxx / 255.255.255.0
123.123.123.xxx / 255.255.255.0
● Use the PC that operates on Windows 2000, Windows XP, or Windows Vista (excludes their x64 bit
versions).
2. Firmware Updating Procedure
Update the fi-5000N firmware following the procedure below.
1)
Disconnect the USB cable from the fi-5000N, and then turn on the fi-5000N.
⇒The fi-5000N will show a message ”The scanner is not connected.”
2)
Execute “fi5kN_FirmUp.exe” downloaded from the web page.
⇒The Firmware Update Tool for fi-5000N dialog box will appear.
3)
Confirm the IP address of the fi-5000N.
⇒You can get the IP address following the instructions given below.
《How to Get the IP Address of the fi-5000N》
(1) When the message “The scanner is not connected.” appears on fi-5000N’s Message Display, press the
[SET] key. The settings screen appears.
(2) With the [↓] key, select [Show Network Config].
(3) As the IP address of the fi-5000N is displayed on the [IP: ] line of the settings screen, write it down in the
form below:
IP address of fi-5000N:
.
.
.
(4) Press the [ESC] key on the fi-5000N twice to return to the state where the message “The scanner is
not connected.” is displayed.
4)
Type in the IP address of the fi-5000N, which you took a note of in Step 3) above, in the [IP Address]
field shown below.
5)
Click the [Update Firmware] button to start searching for the fi-5000N whose IP address matches
the entered one.
⇒The dialog box will display the following message, showing that the program is searching for the
specified IP address.
⇒If the searching is successful, the message in the dialog box will change, showing that the
program is updating the firmware.
Note
Do NOT turn off the fi-5000N and PC during the updating process.
《When Searching of the fi-5000N is Unsuccessful》
The following message appears on the PC:
In case the searching has failed, confirm:
・ The IP address of the fi-5000N entered in Step 4) is correct.
・ The PC and the fi-5000N are configured within the same subnet.
・ The LAN cable connection is proper.
・ The fi-5000N is turned on.
⇒The following message box will appear once the firmware updating is completed.
6)
Click the [OK] button.
⇒The Firmware Update Tool will terminate.
7)
Turn off the fi-5000N, and proceed to Section 3 “Updating the Firmware Revision Number.”
《When Updating of the Firmware is Unsuccessful》
The following message appears on the PC:
Here, confirm:
Case 1:
Case 2:
If the fi-5000N does not show the message “The scanner is not connected,” follow the
instructions in 《How to Confirm the IP Address of the fi-5000N》 in Step 3) above, or turn on
the fi-5000N again. When the message “The scanner is not connected.” appears, do the
procedure from Step 2) above.
If the fi-5000N shows the message “Backup mode for only recovering main program” after it is
turned on, update the firmware following the instructions in Firmware Updating from Backup
Mode below.
Firmware Updating from Backup Mode
Should the firmware updating fail due to the fi-5000N being powered OFF during updating, etc., start the
fi-5000N in backup mode. If the fi-5000N is started in backup mode, the message “Backup mode for only
recovering main program” will appear.
Note
If a static IP address is used in normal mode, the same address (which you took a note of in Step 3))
will be used while the fi-5000N operates in backup mode. If DHCP is used in normal mode, the
fi-5000N will use an IP address of 192.168.1.1 in backup mode.
To update the firmware in backup mode, do Steps 2) to 6) in Section 2 “Firmware Updating Procedure” for
the PC while the fi-5000N shows the message “Backup mode for only recovering main program.”
The fi-5000N will start in normal mode if the firmware updating is completed successfully.
3. Updated Firmware Revision Number
After the firmware updating, you need to update the revision number of the fi-5000N as shown below:
Revision number before updating
A0
A1
D0
→
→
→
Revision number after updating
A2
A2
D1
Update the revision number on the manufacture label on the bottom side of the fi-5000N. Circle the
revision number after updating as shown below. (The revision number example in the figure is “A2.”)
MODEL
PART NO.
SER. NO.
DATE
fi-5000N
PA03368-B00*
******
2005-2
16V
A
B
0.3A
1.0kg
MADE IN JAPAN
This has completed the procedure for updating the firmware.
Note
You need to update the firmware only once for each fi-5000N.