P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S

CBX32MV

DAVE LENNOX SIGNATURE

®

COLLECTION

R-410A Ready - Multi-Position - Variable Speed

Bulletin No. 210352

July 2012

Supersedes June 2012

Nominal Capacity - 1.5 to 5+ Tons

Optional Electric Heat - 2.5 to 25 kW

MODEL NUMBER IDENTIFICATION

CB X 32 mV - 036 - 230 - 6 - 01

Unit Type

CB = Air Handler

Refrigerant Type

X = R-410A

Series

Configuration

MV = Multi-Position, Variable

Speed Blower Motor

Nominal Cooling Capacity - Tons

018/024 = 1.5 to 2 tons

024/030 = 2 to 2.5 tons

036 = 3 tons

048 = 4 tons

060 = 5 tons

068 = 5+ tons

Minor Revision Number

Refrigerant Metering Device

2 = Fixed Orifice

3 = TXV - Bleedport (indoor unit)

4 = TXV - Non-bleedport (indoor unit)

5 = TXV - Non-bleedport (outdoor unit)

6 = TXV - R-410A Non-bleedport (indoor unit)

Voltage

230 = 208/230V-60hz-1ph

A

FEATURES

Contents

Blower Data ................................................................10

Dimensions - Downflow ..............................................21

Dimensions - Upflow ...................................................20

Electrical Data...............................................................8

Electric Heat Data .......................................................15

Features........................................................................2

Installation Clearances With Electric Heat ....................8

Model Number Identification .........................................1

Optional Accessories ....................................................8

Replacement Circuit Breakers ......................................9

Specifications................................................................8

Warranty

All covered components - Limited ten years in residential applications, one year in non-residential applications.

Refer to Lennox Limited Warranty Certificate included with each unit for additional details.

Approvals

Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 210/240.

Optional electric heaters are rated in accordance with

US Department of Energy (DOE) test procedures and

Federal Trade Commission (FTC) labeling regulations.

Blower performance data according to unit tests conducted in Lennox air test chamber.

Air handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC.

ISO 9001 Registered Manufacturing Quality System.

Applications

1.5 to 5+ ton nominal sizes.

Multi-position (upflow, downflow or horizontal) applications.

Applicable to expansion valve systems in R-410A cooling applications and check and expansion valve systems in R-410A heat pump applications.

Applicable to Lennox Harmony III™ zoning system.

Wide-range check and expansion valve is factory installed.

See bulletins in section Air Conditioners for cooling capacities.

See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities.

Optional field installed electric heaters available in several sizes for additive heating capacity.

Zoning Applications

Units can be used with certain zoning systems.

Zone control panel MUST be able to interface and communicate with the variable speed motor in the unit.

Lennox Harmony III™ zoning system has this capability.

CBX32MV / Page 2

J

D

G

B

H

C

I

F

E

B

REFRIGERANT SYSTEM

Copper Tube/Enhanced Fin Indoor Coil

Lennox designed and fabricated twin coils.

Assembled in “A” configuration.

Provides extra large surface and contact area, excellent heat transfer and low air resistance for maximum efficiency.

Precise circuiting for uniform refrigerant distribution.

Precisely spaced ripple-edged aluminum fins fitted to durable seamless copper tubes.

Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area.

Lanced fins provide maximum exposure of fin surface to air stream.

Long life copper tubing is easy to service.

Rifled tubing provides superior heat transfer.

Flared shoulder tubing joints and silver soldering provide tight, leakproof joints.

Coil thoroughly factory tested under high pressure to insure leakproof construction.

FEATURES

REFRIGERANT SYSTEM (CONTINUED)

C

D

Refrigerant Line Connections

Suction (vapor) and liquid lines have sweat connections that extended outside of the cabinet for ease of connection.

See dimension drawings for locations.

Check and Expansion Valve Furnished

For use with R-410A systems.

Wide range valve with Chatleff style fitting.

Factory installed on all models, internal to cabinet.

E

Cabinet

Constructed of heavy-gauge galvanized steel.

Completely insulated with thick fiberglass insulation.

Pre-painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels.

Units are shipped in one piece but may be disassembled into two separate sections for ease of installation in tight applications. See dimension drawings.

Thick rubber gasket between sections of the two piece cabinets provides an air tight seal.

No external screw heads on sides of cabinet for tight installations without damage to walls or woodwork.

Removable panels provide complete service access.

Electrical inlets provided in sides and top of cabinet.

See dimension drawings for locations.

Low Leakage Cabinet

All models have less than 2% air leakage and meet

ANSI/ASHRAE Standard 193-2010 “Method of Test for

Determining the Air Tightness of HVAC Equipment”.

Multi-Position Capability

Shipped for upflow and horizontal right-hand discharge.

Quickly converted to downflow or left-hand, horizontal air discharge.

Easily converts to downflow position with furnished coil support rails and filter support rack.

Dual Position Drain Pans

Drain pans designed for upflow, downflow or horizontal applications.

Deep, corrosion resistant plastic drain pans have dual pipe drains.

See dimension drawings.

OPTIONS

Downflow Combustible Flooring Base

Base is required for models with electric heat installed in downflow position on combustible floors.

Horizontal Support Frame Kit (Not for -068)

Provides support of unit in horizontal applications.

Consists of (2) 1 x 1-1/2 x 32-5/8 in. and (2) 1 x 3 x

53-7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes.

Bolts and nuts furnished for field assembly.

Suspending rods must be field provided.

Side Return Unit Stand (Upflow Only, Not for -068)

Raises unit 16 in. above floor for side return air duct connection.

Eliminates need for wooden platform construction.

All aluminum construction.

Two adjustable frames fit -018/024 thru -060 models.

Wall Hanging Bracket Kit (Upflow Only)

Allows unit to be hung on wall at any height.

Consists of heavy-gauge steel support brackets (one for air handler, one for wall mount).

Screws furnished for fastening one bracket to unit.

Bolts for fastening one bracket to wall are field provided.

F

BLOWER

Variable-Speed Blower Motor

High efficiency multi-speed blower motor maintains specified air volumes up to a maximum of 0.8 in. w.g. total external static.

Multi-speed operation is achieved by the use of an ECM

(Electronically Commutated

Motor) motor.

Allows cooling ramping profiles

(field selectable) for enhanced dehumidification.

Motor accelerates and decelerates gradually, reducing start-up and shut-down sound.

G

Leadless blower motor features simple plug-in connections.

Motor is controlled by the icomfort™ control that allows blower to operate at two of eight air volumes or speeds available.

Speeds may be field selected on icomfort™ control depending on size of air handler and air volume desired.

See blower performance tables.

Blower Assembly

Lennox designed and built, direct drive blower.

Each blower is statically and dynamically balanced as an assembly before installation in the unit.

Blower motor is resiliently mounted to blower assembly.

Blower slides out of cabinet for servicing.

CBX32MV / Page 3

FEATURES

CONTROLS

H

icomfort™ Control

Advanced control board communicates information about various operating parameters in the air handler to the optional

icomfort Wi-Fi™ Thermostat to constantly maintain the highest level of comfort, performance and efficiency available.

Auto Configuration - On start-up the control board automatically sends a description of the unit to the optional

icomfort™ Thermostat to automatically configure the number of stages and features available.

Connections for connecting a conventional heating/ cooling thermostat are also provided on the board.

Board also features:

• Lennox Humiditrol

®

Whole Home Dehumidification

System (EDA) compatible.

• EEPROM storage of all local configurations.

• Non-volatile memory storage of 100 alarm codes with display of last 10 codes for troubleshooting.

• Connections for optional outdoor temperature sensor

(communicates temperature on RSBUS to thermostat).

• Controls evaporator humidity by controlling blower and compressor staging on two-stage outdoor units.

• Two stages - HEAT and COOL (with four different air volume selections for each) are made by simple jumper pins on board.

• ADJUST jumper pin allows approximately 10% higher, normal or 10% lower motor speed selection within HEAT and COOL speeds selected for fine tuning air volume.

• DELAY jumper pin allows selection of blower motor de-humidification profiles during cooling mode.

Option 1 - Motor runs at 100% of capacity until demand met. Once demand is met, motor ramps down to stop.

Option 2 −

Cooling: When cool demand is initiated, motor ramps up to 100% and runs at 100% until demand is satisfied. Once demand is met, motor runs at 100% for 45 seconds, then ramps down to stop.

Heat Pump: When heat pump demand is initiated,

30 second motor on delay starts. After the motor on delays expires, motor ramps up to 100% and runs at

100% until demand is satisfied. Once demand is met, motor runs at 100% for 45 seconds, then ramps down to stop.

Option 3 - Motor runs at 82% of capacity for approximately 7.5 minutes, then 100% capacity (if needed) until demand is satisfied. Once demand is met, motor ramps down to stop.

Option 4 - Motor runs at 50% capacity for 30 seconds, then 82% capacity for approximately 7.5 minutes. If demand is not satisfied, motor runs at 100% capacity until demand is met. Once demand is met, motor runs at

50% capacity for 30 seconds, then ramps down to stop.

Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing.

Dehumidification (Active or Humiditrol

®

Option) - A jumper on the control board must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System.

A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system. After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm.

Electric Heat Operation - Control for up to three electric heat stages.

EvenHeater

®

Electric Heat Control - Up to four electric heat stages are available when utilizing the

EvenHeater

®

control feature furnished on the icomfort™ control. EVENHEAT jumper position on control board determines target discharge air temperature of 85 °F,

100 °F, 115°F or 130°F. Default setting is 85°F. An optional Discharge Air Sensor is required.

Heat Pump Operation - A jumper on the control board must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received.

Two Stage Cooling Operation - A jumper on the control board must be clipped to enable operation with a two-stage air conditioner. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings.

Lennox System Operations Monitor Connection -

Monitors outdoor unit operation. (communicating mode).

Continuous Blower Speed - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 28%, 38% (default setting), 70% and

100%.

Transformer - 70VA transformer furnished as standard.

Factory installed in the unit control box.

Accessory Terminals - Two accessory terminals are furnished for additional power supply requirements for 120 volt (less than 1 amp) power humidifiers and powered air cleaners. One 24 volt humidifier output is furnished for non-powered humidifiers.

Control board is factory installed in the unit control box.

CBX32MV / Page 4

FEATURES

CONTROLS (CONTINUED)

OPTIONS

icomfort Wi-Fi™ Thermostat (part of the icomfort™

Residential Communicating Control System)

The icomfort Wi-Fi™ Thermostat recognizes and connects to all icomfort™enabled products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency.

Also recognizes model and serial number information for icomfort™-enabled products to simplify system installation.

Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail.

Dealer Dashboard features online real-time monitoring of installed icomfort systems.

A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen.

Easy to read 7 inch color screen (measured diagonally).

Conventional outdoor units (not icomfort™-enabled) can easily be added and controlled by the

icomfort Wi-Fi™

Thermostat.

Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting.

Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring.

See the icomfort Wi-Fi™ Thermostat Product

Specifications bulletin in the Controls section for more information.

ComfortSense

®

7000 Touchscreen Thermostat

Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat.

4 Heat/2 Cool.

Auto-changeover.

Controls humidity during cooling mode.

Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control,

Humiditrol

®

control, and equipment maintenance reminders.

HOME

MODE

AUTO

SCHED

ON

SCHEDULE OPTIONS

SET AT

HEAT

SET AT

COOL

WED

INDOOR RH 26%

AN 21 12:35AM

Easy-to-use, menu driven thermostat with a back-lit,

LCD touchscreen.

Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol

®

applications.

See the ComfortSense

®

7000 Product Specifications bulletin in the Controls section for more information.

Outdoor Temperature Sensor

Used with icomfort™ thermostats and ComfortSense

®

7000 thermostat.

When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat.

NOTE - Sensor is required for

Humiditrol

®

applications.

Thermostat

Thermostat (icomfort™ thermostats or programmable/ non-programmable) is not furnished with unit.

See Thermostat bulletins in Controls Section and

Lennox Price Book for selection.

Hot Water Heat Kit

Air handler kit to control a third-party hot water boiler with a hot water heating coil installed downstream from the air handler.

Kit contains all necessary relays and plug-in wiring harness to control boiler.

NOTE - This kit is only approved for use in systems using either the ComfortSense

®

7000 or icomfort™-enabled thermostats.

CBX32MV / Page 5

FEATURES

OPTIONAL Electric Heat

I

Field install internal to unit cabinet.

Available in several voltages and kW sizes.

See Electric Heat tables.

Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life.

Each element equipped with accurately located limit control with fixed temperature off setting and automatic reset.

Supplemental thermal cutoff limit control, provides positive protection in case of excessive temperatures.

Thermal sequencer relay brings elements on and off line, in sequence and equal increments, with time delay between each.

Initiates and terminates blower operation.

Heating control relay(s) furnished as standard.

Control box and access cover constructed of heavy gauge galvanized steel.

Factory assembled with controls installed and wired.

Electric heat low voltage controls plug-in to air handler.

Circuit Breaker Models

The following heaters are equipped with circuit breakers for overload and short circuit protection:

ECB40-4CB, -5CB, -6CB, -8CB, -9CB, -12.5CB, -15CB,

-20CB and -25CB (208/240V-1ph)

ECB40-15CB, -20CB and -25CB (208/240V-3ph

Factory wired and mounted on electric heat unit.

Current sensitive and temperature actuated.

Manual reset.

Circuit breakers qualify as disconnect means at unit in many areas, eliminate the need for field provided disconnect.

Consult local electrical code in your area.

OPTIONS

Circuit Breaker Cover Kit

Flexible plastic cover protects circuit breaker.

Recommended in areas with high humidity or unconditioned areas to prevent nuisance tripping.

Single-Point Power Source Control Box

Control Box may be used with optional electric heat when single power supply is connected to multi-circuit electric heat.

Field installs external to the unit cabinet on either side or top.

Constructed of heavy gauge steel, baked enamel finish, prepunched mounting holes, electrical inlet knockouts, and terminal strip.

Removable cover provides easy access.

Dimensions (H x W x D) - 7 x 7 x 4 in.

INDOOR AIR QUALITY

J

Air Filter

Tool-less access to filter area for quick and easy servicing.

Disposable frame type filter furnished and factory installed in rails in cabinet.

See Specifications tables for sizes.

OPTIONS

Healthy Climate

®

Germicidal UVC Light

Germicidal lamp emits C-Band ultra-violet (UVC) energy at 253.7 nanometers, which is proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UVC germicidal light greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Surfaces must be cleaned prior to UVC light being installed.

Available in 24 volt and 110/230V-1ph models.

Air handlers have a factory provided knockout in the coil delta plate for mounting light within coil area.

Shielding baffle is required when installing light above a non-UVC resistant component, such as a filter.

Baffle must be ordered separately.

CBX32MV / Page 6

SPECIFICATIONS

General Data

Connections in.

Indoor

Coil

Model Number CBX32MV-018/024 CBX32MV-024/030

Nominal tonnage 1.5 to 2 2 to 2.5

Refrigerant

Suction / vapor (o.d.) line - sweat

Liquid line (o.d.) - sweat

Condensate drain - in. (fpt)

Net face area - ft.

2

Tube outside diameter - in.

R-410A

5/8

3/8

(2) 3/4

3.56

3/8

R-410A

3/4

3/8

(2) 3/4

4.44

3/8

Blower Data

Filters

Number of rows

Fins per inch

Wheel nominal diameter x width - in.

Motor output - hp

1

Number and size - in.

Shipping Data - 1 Package - lbs.

3

12

10 x 7

1/2

(1) 15 x 20 x 1

126

3

12

10 x 8

1/2

(1) 20 x 20 x 1

152

ELECTRICAL DATA

Voltage - phase - 60hz

2

Maximum overcurrent protection (unit only)

3

Minimum circuit ampacity (unit only)

CONTROLS

208/230V-1ph

15

5

208/230V-1ph

15

5

CBX32MV-036

3

R-410A

3/4

3/8

(2) 3/4

5.0

3/8

3

12

10 x 8

1/2

(1) 20 x 20 x 1

183

208/230V-1ph

15

5

icomfort Wi-Fi™ Thermostat

4

Remote Outdoor Sensor (for dual fuel and Humiditrol

®

)

5

Discharge Temperature Sensor

ComfortSense

®

7000 Thermostat

Remote Outdoor Sensor (for dual fuel and Humiditrol

®

)

88W58

X2658

88K38

Y0349

X2658

88W58

X2658

88K38

Y0349

X2658

88W58

X2658

88K38

Y0349

X2658

OPTIONAL ACCESSORIES - order separately

Circuit Breaker Cover Kit

Downflow Combustible Flooring Base

Electric Heat

Healthy Climate

Germicidal Light

UVC-24V (24V)

Shielding Baffle (required)

UVC-41W-S (110/230v-1 ph)

Shielding Baffle (required)

82W01

34J72

X9423

Y2120

X9424

X9900

56J18

82W01

44K15

See Electric Heat Data tables

X9423

Y2120

X9424

X9900

56J18

82W01

44K15

X9423

Y2120

X9424

X9900

56J18 Horizontal Support Frame Kit

Hot Water Heat Kit

Side Return Unit Stand (Upflow)

Single-Point Power Source Control Box

90W84

45K31

21H39

90W84

45K32

21H39

90W84

45K32

21H39

Wall Hanging Bracket Kit (Upflow) 45K30 45K30 45K30

1

Disposable frame type filter.

2

HACR type circuit breaker or fuse.

3

Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

4

Remote Outdoor Sensor may be used with an icomfort™-enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conven-

5 tional outdoor unit.

Optional for EvenHeater

®

electric heat operation and service diagnostics.

INSTALLATION CLEARANCES WITH ELECTRIC HEAT

Cabinet

To Plenum

To Outlet Duct within 3 feet (914 mm)

Floor

0 inch (0 mm)

1 inch (25 mm)

1 inch (25 mm)

See Note #1

Service / Maintenance See Note #2

1

Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible

2 flooring base.

Front service access - 24 inches (610 mm) minimum.

NOTE - If cabinet depth is more than 24 inches (610 mm), allow a minimum of the cabinet depth plus 2 inches (51 mm).

CBX32MV / Page 7

SPECIFICATIONS

General Data

Connections in.

Indoor

Coil

Model Number

Nominal tonnage

Refrigerant

Suction / vapor (o.d.) line - sweat

Liquid line (o.d.) - sweat

Condensate drain - in. (fpt)

Net face area - ft.

2

Tube outside diameter - in.

Blower Data

Filters

Number of rows

Fins per inch

Wheel nominal diameter x width - in.

Motor output - hp

1

Number and size - in.

Shipping Data - 1 Package - lbs.

ELECTRICAL DATA

Voltage - phase - 60hz

2

Maximum overcurrent protection (unit only)

3

Minimum circuit ampacity (unit only)

CBX32MV-048

4

R-410A

7/8

3/8

(2) 3/4

7.22

3/8

3

12

12 x 9

1

(1) 20 x 24 x 1

212

CBX32MV-060

5

R-410A

7/8

3/8

(2) 3/4

7.22

3/8

3

12

12 x 9

1

(1) 20 x 24 x 1

212

CBX32MV-068

5+

R-410A

1-1/8

3/8

(2) 3/4

7.77

3/8

3

12

15 x 9

1

(1) 20 x 25 x 1

244

208/230V-1ph

20

11

208/230V-1ph

20

11

208/230V-1ph

20

11

CONTROLS

icomfort

4

®

Touch Communicating Thermostat

Remote Outdoor Sensor (for dual fuel and Humiditrol

®

)

5

Discharge Temperature Sensor

ComfortSense

®

7000 Thermostat

Remote Outdoor Sensor (for dual fuel and Humiditrol

®

)

49W95

X2658

88K38

Y0349

X2658

49W95

X2658

88K38

Y0349

X2658

49W95

X2658

88K38

Y0349

X2658

OPTIONAL ACCESSORIES - order separately

Circuit Breaker Cover Kit

Downflow Additive Base

Electric Heat

Healthy Climate

Germicidal Light

Horizontal Support Frame Kit

Hot Water Heat Kit

Side Return Unit Stand (Upflow)

Shielding Baffle (required)

Single-Point Power Source Control Box

Wall Hanging Bracket Kit (Upflow)

UVC-24V (24V)

Shielding Baffle (required)

UVC-41W-S (110/230v-1 ph)

82W01

44K15

X9423

Y2120

X9424

X9900

56J18

90W84

45K32

21H39

45K30

82W01

44K15

See Electric Heat Data tables

X9423

Y2120

X9424

X9900

56J18

90W84

45K32

21H39

45K30

82W01

44K15

X9423

Y2120

X9424

X9900

N/A

90W84

N/A

21H39

45K30

1

Disposable frame type filter.

2

HACR type circuit breaker or fuse.

3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

4

Remote Outdoor Sensor may be used with an icomfort™-enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conven-

5 tional outdoor unit.

Optional for EvenHeater

®

electric heat operation and service diagnostics.

REPLACEMENT CIRCUIT BREAKERS

Voltage

208/240V - 1 Phase

208/240V - 3 Phase

Description

25 amp, 2 pole

30 amp, 2 pole

35 amp, 2 pole

40 amp, 2 pole

45 amp, 2 pole

50 amp, 2 pole

60 amp, 2 pole

30 amp, 3 pole

35 amp, 3 pole

40 amp, 3 pole

45 amp, 3 pole

50 amp, 3 pole

60 amp, 3 pole

Catalog No.

41K13

17K70

72K07

49K14

17K71

41K12

17K72

64W47

41K14

41K16

18M86

41K15

41K17

CBX32MV / Page 8

BLOWER DATA

CBX32MV-018/024 BLOWER PERFORMANCE

0 through 0.80 in. w.g. External Static Pressure Range

“ADJUST”

Jumper

Setting

+

NORM

1 cfm

715

670

580

“HEAT” Speed

2 cfm

855

770

700

3 cfm

1000

900

800

Jumper Speed Positions

4 cfm

1130

1035

930

1 cfm

465

425

385

“COOL” Speed

2 cfm

690

620

560

3 cfm

900

825

735

4 cfm

1050

950

850

NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.

First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the same second-stage COOL speed selected.

Lennox Harmony III™ Zone Control applications - minimum blower speed is 250 cfm.

CBX32MV-018/024 BLOWER MOTOR WATTS

AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

0

100

0.1

113

Motor Watts @ Various External Static Pressures - in. wg.

0.2

126

0.3

142

0.4

154

0.5

172

0.6

190

“COOL” Speed

Tap 2

Tap 3

Tap 4

Tap 1

Tap 2

Tap 3

155

237

338

36

89

183

176

260

361

47

103

198

197

289

379

61

118

229

221

305

409

71

129

248

237

314

433

81

143

266

260

337

457

95

163

290

278

356

447

106

177

307

Tap 4

266 294 315

AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

Tap 2

0

77

118

0.1

96

136

0.2

106

154

330

0.3

123

177

349

0.4

130

189

373 390

Motor Watts @ Various External Static Pressures - in. wg.

0.5

150

212

0.6

165

224

“COOL” Speed

Tap 3

Tap 4

Tap 1

183

264

30

198

284

41

224

300

55

248

326

62

264

343

76

284

367

86

307

385

94

Tap 2

Tap 3

Tap 4

71

137

211

83

158

225

101

176

249

113

199

272

125

219

295

138

238

318

156

254

331

AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)

Jumper

Speed Positions

0 0.1

Motor Watts @ Various External Static Pressures - in. wg.

0.2

0.3

0.4

0.5

0.6

“HEAT” Speed Tap 1

Tap 2

Tap 3

59

95

132

73

106

148

89

118

171

106

136

186

113

152

211

130

171

225

142

183

248

“COOL” Speed

Tap 4

Tap 1

Tap 2

Tap 3

Tap 4

195

27

57

110

148

217

35

65

124

170

242

47

83

141

195

259

59

94

157

207

283

71

110

176

230

302

77

119

188

248

314

88

134

213

272

0.7

156

200

266

336

92

148

231

282

118

197

327

411

0.7

206

295

373

426

0.7

178

247

321

406

106

166

273

342

0.8

173

215

284

349

106

166

242

306

135

207

343

401

0.8

230

310

390

406

0.8

201

265

343

390

114

185

296

367

CBX32MV / Page 9

BLOWER DATA

CBX32MV-024/030 BLOWER PERFORMANCE

0 through 0.80 in. w.g. External Static Pressure Range

“ADJUST”

Jumper

Setting

+

NORM

1 cfm

800

725

655

“HEAT” Speed

2 cfm

935

850

765

3 cfm

1070

975

880

Jumper Speed Positions

4 cfm

1210

1100

990

1 cfm

660

600

540

“COOL” Speed

2 cfm

880

800

720

3 cfm

1100

1000

900

4 cfm

1320

1200

1080

NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.

First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the same second-stage COOL speed selected.

Lennox Harmony III™ Zone Control applications - minimum blower speed is 250 cfm.

CBX32MV-024/030 BLOWER MOTOR WATTS

AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

0

65

0.1

90

Motor Watts @ Various External Static Pressures - in. wg.

0.2

120

0.3

145

0.4

185

0.5

210

0.6

240

“COOL” Speed

Tap 2

Tap 3

Tap 4

Tap 1

Tap 2

Tap 3

95

140

215

45

80

150

125

190

250

60

110

195

150

225

285

90

135

225

185

250

315

120

165

260

230

290

350

140

205

295

265

320

390

155

250

320

310

350

440

165

285

370

Tap 4

265 315 350

AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

Tap 2

0

50

80

0.1

75

105

0.2

100

130

400

0.3

135

155

440

0.4

155

200

485 525

Motor Watts @ Various External Static Pressures - in. wg.

0.5

180

245

0.6

195

265

“COOL” Speed

Tap 3

Tap 4

Tap 1

110

155

40

150

205

55

175

230

80

200

270

105

235

290

120

275

325

130

320

360

150

Tap 2

Tap 3

Tap 4

65

105

200

90

145

245

120

175

275

145

220

300

190

250

335

210

285

385

240

335

420

AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)

Jumper

Speed Positions

0 0.1

Motor Watts @ Various External Static Pressures - in. wg.

0.2

0.3

0.4

0.5

0.6

“HEAT” Speed Tap 1

Tap 2

Tap 3

45

60

85

65

85

105

90

110

130

110

145

165

130

175

210

150

200

245

165

215

280

“COOL” Speed

Tap 4

Tap 1

Tap 2

Tap 3

Tap 4

115

30

55

85

145

145

50

75

115

175

175

70

100

135

215

205

90

135

175

245

230

100

155

210

280

280

115

185

255

325

325

125

190

295

355

0.7

190

235

305

370

140

210

320

410

185

315

425

555

0.7

250

345

405

480

0.7

215

295

350

405

165

260

370

470

0.8

195

240

330

390

165

225

345

450

200

335

465

605

0.8

275

365

450

505

0.8

230

310

390

460

180

285

405

515

CBX32MV / Page 10

BLOWER DATA

CBX32MV-036 BLOWER PERFORMANCE

0 through 0.80 in. w.g. External Static Pressure Range

“ADJUST”

Jumper

Setting

+

NORM

1 cfm

1230

1120

1010

“HEAT” Speed

2 cfm

1335

1215

1185

3 cfm

1445

1315

1200

Jumper Speed Positions

4 cfm

1545

1400

1265

1 cfm

900

810

730

“COOL” Speed

2 cfm

1225

1125

1000

3 cfm

1380

1275

1135

4 cfm

1545

1400

1265

NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.

First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the same second-stage COOL speed selected.

Lennox Harmony III™ Zone Control applications - minimum blower speed is 250 cfm.

CBX32MV-036 BLOWER MOTOR WATTS

AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

0

220

0.1

235

Motor Watts @ Various External Static Pressures - in. wg.

0.2

265

0.3

290

0.4

310

0.5

335

0.6

360

“COOL” Speed

Tap 2

Tap 3

Tap 4

Tap 1

Tap 2

Tap 3

285

345

470

90

225

305

305

365

495

110

245

325

330

405

515

135

265

350

355

430

530

155

290

390

380

455

545

180

320

420

405

485

560

195

350

445

430

515

575

210

370

475

Tap 4

470 495 515

AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

Tap 2

0

155

225

0.1

185

245

0.2

215

270

530

0.3

240

295

545

0.4

265

325

560 575

Motor Watts @ Various External Static Pressures - in. wg.

0.5

285

345

0.6

300

370

“COOL” Speed

Tap 3

Tap 4

Tap 1

275

320

100

290

345

120

315

375

140

340

405

150

375

435

185

400

460

190

420

485

215

Tap 2

Tap 3

Tap 4

160

255

320

190

270

345

220

295

375

240

320

405

265

345

435

290

375

460

320

400

485

AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)

Jumper

Speed Positions

0 0.1

Motor Watts @ Various External Static Pressures - in. wg.

0.2

0.3

0.4

0.5

0.6

“HEAT” Speed Tap 1

Tap 2

Tap 3

120

140

185

135

165

210

165

195

240

185

215

265

205

245

285

225

270

310

245

300

330

“COOL” Speed

Tap 4

Tap 1

Tap 2

Tap 3

Tap 4

245

65

120

160

245

255

90

140

190

255

290

105

160

225

290

310

125

185

240

310

335

145

215

275

335

355

160

235

295

355

380

185

255

320

380

0.7

265

315

360

405

190

275

350

405

230

395

505

595

0.7

385

450

545

595

0.7

335

390

445

515

240

340

420

515

0.8

300

335

385

430

215

295

380

430

250

410

535

610

0.8

465

475

570

610

0.8

355

415

465

540

250

365

445

540

CBX32MV / Page 11

BLOWER DATA

CBX32MV-048 and cbx32MV-060 BLOWER PERFORMANCE

0 through 0.80 in. w.g. External Static Pressure Range

“ADJUST”

Jumper

Setting

+

NORM

1 cfm

1850

1705

1560

“HEAT” Speed

2 cfm

1960

1800

1625

3 cfm

2090

1900

1720

Jumper Speed Positions

4 cfm

2150

2005

1770

1 cfm

1625

1425

1205

“COOL” Speed

2 cfm

1820

1625

1375

3 cfm

2055

1805

1555

4 cfm

2145

2005

1725

NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.

First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the same second-stage COOL speed selected.

Lennox Harmony III™ Zone Control applications - minimum blower speed is 450 cfm.

CBX32MV-048 and cbx32MV-060 BLOWER MOTOR WATTS

AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

0

455

0.1

505

Motor Watts @ Various External Static Pressures - in. wg.

0.2

540

0.3

585

0.4

630

0.5

665

0.6

710

“COOL” Speed

Tap 2

Tap 3

Tap 4

Tap 1

Tap 2

Tap 3

555

680

730

300

425

625

595

720

780

335

475

660

645

770

825

370

500

705

675

820

870

360

545

755

730

865

920

435

585

810

780

900

970

465

635

850

820

945

1020

500

670

885

Tap 4

700 750 800

AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

Tap 2

0

360

400

0.1

385

440

0.2

425

485

845

0.3

465

520

895

0.4

495

555

940 990

Motor Watts @ Various External Static Pressures - in. wg.

0.5

525

595

0.6

565

640

“COOL” Speed

Tap 3

Tap 4

Tap 1

480

580

215

520

625

235

560

665

275

605

710

295

640

760

330

685

800

360

765

835

400

Tap 2

Tap 3

Tap 4

310

415

580

335

445

610

375

490

655

405

535

695

440

565

740

465

605

785

500

650

830

AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)

Jumper

Speed Positions

0 0.1

Motor Watts @ Various External Static Pressures - in. wg.

0.2

0.3

0.4

0.5

0.6

“HEAT” Speed Tap 1

Tap 2

Tap 3

265

320

375

305

350

410

340

395

435

370

420

470

410

450

515

440

475

545

460

515

575

“COOL” Speed

Tap 4

Tap 1

Tap 2

Tap 3

Tap 4

400

140

200

280

375

435

170

230

315

420

480

195

260

340

440

525

215

285

380

475

555

250

315

415

515

595

275

355

445

550

640

300

385

465

575

0.7

745

865

985

1055

535

710

940

1030

0.7

505

545

610

670

335

415

505

610

0.7

600

670

785

875

430

530

675

870

0.8

540

580

645

700

360

450

540

645

0.8

780

895

1030

1110

575

745

970

1080

0.8

635

705

805

925

465

565

715

910

CBX32MV / Page 12

BLOWER DATA

CBX32MV-068 BLOWER PERFORMANCE

0 through 0.80 in. w.g. External Static Pressure Range

“ADJUST”

Jumper

Setting

+

NORM

1 cfm

1875

1760

1550

“HEAT” Speed

2 cfm

1975

1825

1650

3 cfm

2090

1920

1725

Jumper Speed Positions

4 cfm

2150

2030

1800

1 cfm

1640

1465

1250

“COOL” Speed

2 cfm

1840

1625

1390

3 cfm

2075

1800

1560

4 cfm

2150

2000

1720

NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.

First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the same second-stage COOL speed selected.

Lennox Harmony III™ Zone Control applications - minimum blower speed is 450 cfm.

CBX32MV-068 BLOWER MOTOR WATTS

AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

0

365

0.1

410

Motor Watts @ Various External Static Pressures - in. wg.

0.2

455

0.3

495

0.4

545

0.5

610

0.6

660

“COOL” Speed

Tap 2

Tap 3

Tap 4

Tap 1

Tap 2

Tap 3

430

540

665

255

355

505

485

585

710

290

390

565

540

635

755

320

425

610

590

695

770

365

475

70

640

750

790

415

515

715

690

800

810

455

580

790

765

815

830

505

630

815

Tap 4

725 745 755

AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)

Jumper

Speed Positions

“HEAT” Speed Tap 1

Tap 2

0

310

345

0.1

345

385

0.2

385

420

770

0.3

425

460

790

0.4

465

500

810 830

Motor Watts @ Various External Static Pressures - in. wg.

0.5

510

620

0.6

560

615

“COOL” Speed

Tap 3

Tap 4

Tap 1

385

475

180

430

525

205

480

560

240

525

615

285

580

660

325

640

720

365

695

785

405

Tap 2

Tap 3

Tap 4

250

345

445

285

375

510

320

415

560

355

460

595

410

505

665

455

560

725

505

610

790

AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)

Jumper

Speed Positions

0 0.1

Motor Watts @ Various External Static Pressures - in. wg.

0.2

0.3

0.4

0.5

0.6

“HEAT” Speed Tap 1

Tap 2

Tap 3

215

255

295

245

295

330

285

325

375

325

370

395

375

410

445

415

460

495

460

510

555

“COOL” Speed

Tap 4

Tap 1

Tap 2

Tap 3

Tap 4

335

125

160

225

290

370

150

185

245

325

400

170

225

280

355

445

210

255

320

400

505

245

300

370

445

550

270

335

420

490

600

300

365

460

545

0.7

495

545

600

660

340

415

510

595

550

695

845

850

0.7

725

835

840

845

0.7

610

680

750

845

435

535

670

845

0.8

540

580

660

705

370

450

545

650

590

750

865

870

0.8

790

865

865

870

0.8

665

735

815

810

480

585

735

865

CBX32MV / Page 13

ELECTRIC HEAT DATA - CBX32MV-018/024

Volts

Input kW

Input

1

Btuh

Input

2

Blower

Motor

Full Load

Amps

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

SINGLE PHASE

2.5 kW

4 lbs.

4 kW

4 lbs.

5 kW

4 lbs.

6 kW

4 lbs.

8 kW

5 lbs.

9 kW

5 lbs.

ECB40-2.5

Terminal Block

ECB40-4

(34W86)

(55W89)

Terminal Block

ECB40-4CB (55W90)

30A Circuit breaker

ECB40-5

ECB40-5CB

EB40-6

ECB40-6CB

ECB40-8

ECB40-8CB

ECB40-9CB

(34W87)

Terminal Block

(34W90)

35A Circuit breaker

(34W88)

Terminal Block

(34W91)

40A Circuit breaker

(34W89)

Terminal Block

(34W92)

50A Circuit breaker

(34W93)

60A Circuit breaker

1

1

1

1

1

2

208 1.9

220 2.1

230 2.3

240 2.5

208 3.0

220 3.4

230 3.7

240 4.0

208 3.8

220 4.2

230

240

208

220

230

240

208

220

230

240

208

220

230

240

4.6

5.0

4.5

5.0

5.5

6.0

6.0

6.7

7.3

8.0

6.8

7.6

8.3

9.0

6,400

7,200

7,800

8,500

10,250

11,450

12,550

13,650

12,800

14,300

15,700

17,100

15,400

17,100

18,800

20,500

20,500

22,900

25,100

27,300

23,100

25,800

28,200

30,700

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

1

3

NOTE - Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps.

2

Electric heater capacity only - does not include additional blower motor heat capacity.

4

Amps shown are for blower motor only.

Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

Bold text indicates that the circuit breaker on “CB” circuit breaker models must be replaced with size noted. See Table on Page 6.

5

HACR type circuit breaker or fuse.

4

45

4

45

4

45

50

4

50

4

50

60

60

4

30

4

30

4

30

35

4

35

4

35

4

35

40

20

20

20

20

4

25

4

25

4

25

30

41

43

45

47

46

48

30

31

32

33

35

36

50

52

23

24

25

26

28

29

16

17

18

18

CBX32MV / Page 14

ELECTRIC HEAT DATA - CBX32MV-024/030

Volts

Input kW

Input

1

Btuh

Input

2

Blower

Motor

Full

Load

Amps

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

CkT 1 Ckt 2 CkT 1 Ckt 2

Single Point

Power Source

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

SINGLE PHASE

4 kW

4 lbs.

5 kW

4 lbs.

6 kW

4 lbs.

ECB40-4 (55W89)

Terminal Block

ECB40-4CB (55W90)

30A Circuit breaker

ECB40-5

Terminal Block

ECB40-5CB

35A Circuit breaker

EB40-6

(34W87)

(34W90)

(34W88)

Terminal Block

ECB40-6CB (34W91)

40A Circuit breaker

1

1

1

208 3.0

10,250

220 3.4

11,450

230 3.7

12,550

240 4.0

13,650

208 3.8

12,800

220 4.2

14,300

230 4.6

15,700

240 5.0

17,100

208 4.5

15,400

220 5.0

17,100

230 5.5

18,800

240 6.0

20,500

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

23 - - -

4

25

- - -

24 - - -

4

25

- - -

25 - - -

4

25

- - -

26 - - 30 - - -

28 - - -

4

30

- - -

29 - - -

4

30

- - -

30 - - -

4

30

- - -

31 - - 35 - - -

32 - - -

4

35

- - -

33 - - -

4

35

- - -

35 - - -

4

35

- - -

36 - - 40 - - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

8 kW

5 lbs.

9 kW

5 lbs.

12.5 kW

10 lbs.

ECB40-8

ECB40-8CB

(34W89)

Terminal Block

(34W92)

50A Circuit breaker

ECB40-9CB (34W93)

60A Circuit breaker

ECB40-12.5CB

(34W94)

(1) 30A and

(1) 45A Circuit breaker

1

2

2

208

220

230

6.0

6.7

7.3

20,500

22,900

25,100

240 8.0

27,300

208 6.8

23,100

220 7.6

25,800

230 8.3

28,200

240 9.0

30,700

208 9.4

32,000

220 10.5 35,800

230 11.5 39,200

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

41 - - -

4

45

- - -

43 - - -

4

45

- - -

45 - - -

4

45

- - -

47 - - 50 - - -

46 - - -

4

50

- - -

48 - - -

4

50

- - -

50 - - -

52

24

25

26

- - -

38

4

60

60

25

40

4

25

42 30

- - -

- - -

4

40

4

40

45

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

62

65

68

15 kW

12 lbs.

ECB40-15CB (34W95)

(1) 35A and

(1) 60A Circuit breaker

2

240 12.5 42,600

208 11.3 38,400

220 12.6 43,000

230 13.8 47,000

4.0

4.0

4.0

4.0

27

28

29

30

44 30

45

4

30

48

4

30

50

4

30

52 35

45

4

45

4

50

4

50

60

71

73

77

80

80

80

80

80

240 15.0 51,200 4.0

31 83 90

1

3

NOTE - Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps.

2

Electric heater capacity only - does not include additional blower motor heat capacity.

4

Amps shown are for blower motor only.

Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

Bold text indicates that the circuit breaker on “CB” circuit breaker models must be replaced with size noted. See Table on Page 6.

5

HACR type circuit breaker or fuse.

- - -

- - -

- - -

70

70

70

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

CBX32MV / Page 15

ELECTRIC HEAT DATA - CBX32MV-036

Volts

Input kW

Input

1

Btuh

Input

2

Blower

Motor

Full Load

Amps

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

Ckt 1 Ckt 2 Ckt 1 Ckt 2

Single Point

Power Source

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

SINGLE PHASE

4 kW

4 lbs.

5 kW

4 lbs.

6 kW

4 lbs.

8 kW

5 lbs.

9 kW

5 lbs.

12.5 kW

10 lbs.

15 kW

12 lbs.

20 kW

19 lbs.

ECB40-4 (55W89)

Terminal Block

ECB40-4CB (55W90)

35A Circuit breaker

ECB40-5 (34W87)

Terminal Block

ECB40-5CB (34W90)

35A Circuit breaker

ECB40-6

Terminal Block

ECB40-6CB

40A Circuit breaker

ECB40-8

Terminal Block

ECB40-8CB

50A Circuit breaker

ECB40-9CB

60A Circuit breaker

ECB40-12.5CB

(1) 30A and

(1) 45A Circuit breaker

ECB40-15CB

(34W88)

(34W91)

(34W89)

(34W92)

(34W94)

(34W95)

(1) 35A and

(1) 60A Circuit breaker

ECB40-20CB

(34W93)

(34W96)

(2) 60A Circuit breaker

1

1

1

1

2

2

2

2

208 3.0

10,250

220 3.4

11,450

230 3.7

12,550

240 4.0

13,650

208 3.8

12,800

220 4.2

14,300

230 4.6

15,700

240 5.0

17,100

208 4.5

15,400

220 5.0

17,100

230 5.5

18,800

240 6.0

20,500

208 6.0

20,500

220 6.7

22,900

230 7.3

25,100

240 8.0

27,300

208 6.8

23,100

220 7.6

25,800

230 8.3

28,200

240 9.0

30,700

208 9.4

32,000

220 10.5 35,800

230 11.5

39,200

240 12.5 42,600

208 11.3

38,400

220 12.6 43,000

230 13.8 47,000

240 15.0 51,200

208 15.0 51,200

220 16.8 57,300

230 18.4 62,700

240 20.0 68,200

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

45

45

4

45

4

50

4

50

4

60

50

60

60

60

- - -

- - -

- - -

- - -

4

40

4

40

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

46

48

50

52

28

29

30

31

24

25

26

27

46

48

50

52

41

43

45

47

32

33

35

36

28

29

30

31

23

24

25

26

50

53

55

57

45

48

50

52

38

40

42

44

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

4

45

4

45

4

50

50

4

50

4

4

35

35

35

40

4

45

4

25

4

25

4

25

4

30

4

30

4

30

4

30

4

35

4

30

30

4

30

4

30

4

35

50

4

50

4

60

4

25

25

30

4

50

4

50

60

THREE PHASE

8 kW

5 lbs.

10 kW

6 lbs.

15 kW

12 lbs.

20 kW

19 lbs.

ECB40-8 (34W98)

Terminal Block

ECB40-10

(34W99)

Terminal Block

ECB40-15CB (35W00)

50A Circuit breaker

ECB40-20CB (35W01)

(2) 35A Circuit breaker

1

1

1

2

208

220

230

240

208

220

230

240

208

220

230

240

208

220

230

240

6.0

6.7

7.3

8.0

7.5

8.4

9.2

11.3

20,500

22,900

25,100

27,300

25,600

28,700

31,400

10.0 34,100

38,400

12.6 43,000

13.5 47,000

15.0 51,200

15.0 51,200

16.8 57,300

18.4 62,700

20.0 68,200

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

26

27

28

28

31

33

34

35

44

46

48

50

31

33

34

35

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

26

28

29

30

4

30

30

30

30

35

35

35

40

45

50

50

50

35

35

35

4

40

- - -

- - -

- - -

- - -

4

30

4

30

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

4

30

35

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

57

61

63

65

1

3

NOTE - Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps.

2

Electric heater capacity only - does not include additional blower motor heat capacity.

4

Amps shown are for blower motor only.

Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

Bold text indicates that the circuit breaker on “CB” circuit breaker models must be replaced with size noted. See Table on Page 6.

5

HACR type circuit breaker or fuse.

95

101

105

109

73

77

80

83

62

65

68

71

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

60

70

70

70

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

100

110

110

110

80

80

80

90

70

70

70

80

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

CBX32MV / Page 16

ELECTRIC HEAT DATA - CBX32MV-048 AND CBX32MV-060

Volts

Input kW

Input

1

Btuh

Input

2

Blower

Motor

Full

Load

Amps

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

Ckt 1 Ckt 2 Ckt 3 Ckt 1 Ckt 2 Ckt 3

Single Point

Power Source

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

SINGLE PHASE

4 kW

4 lbs.

5 kW

4 lbs.

6 kW

4 lbs.

8 kW

5 lbs.

9 kW

5 lbs.

12.5 kW

10 lbs.

15 kW

12 lbs.

20 kW

19 lbs.

25 kW

19 lbs.

ECB40-4 (55W89)

Terminal Block

ECB40-4CB (55W90)

35A Circuit breaker

ECB40-5 (34W87)

Terminal Block

ECB40-5CB

(34W90)

35A Circuit breaker

ECB40-6

(34W88)

Terminal Block

ECB40-6CB (34W91)

40A Circuit breaker

ECB40-8 (34W89)

Terminal Block

ECB40-8CB (34W92)

50A Circuit breaker

ECB40-9CB

(34W93)

60A Circuit breaker

THREE PHASE

8 kW

5 lbs.

10 kW

6 lbs.

15 kW

12 lbs.

20 kW

19 lbs.

25 kW

19 lbs.

ECB40-12.5CB

ECB40-15CB

ECB40-20CB

ECB40-25CB

ECB40-8

Terminal block

ECB40-10

Terminal block

ECB40-15CB

50A Circuit breaker

ECB40-20CB

(2) 35A Circuit breaker

ECB40-25CB

(34W94)

(1) 30A and

(1) 45A Circuit breaker

(34W95)

(1) 35A and

(1) 60A Circuit breaker

(34W96)

(2) 60A Circuit breaker

(34W97)

(1) 60A and

(2) 45A Circuit breaker

(34W98)

(34W99)

(35W00)

(35W01)

(35W02)

(1) 50A and

(1) 40A Circuit breaker

1

1

1

1

2

2

2

2

3

1

1

1

2

2

208 3.0 10,250 7.4

220 3.4 11,450 7.4

230 3.7 12,550 7.4

240 4.0 13,650 7.4

208 3.8 12,800 7.4

220 4.2 14,300 7.4

230 4.6 15,700 7.4

240 5.0 17,100 7.4

208 4.5 15,400 7.4

220 5.0 17,100 7.4

230 5.5 18,800 7.4

240 6.0 20,500 7.4

208 6.0 20,500 7.4

220 6.7 22,900 7.4

230 7.3 25,100 7.4

240 8.0 27,300 7.4

208 6.8 23,100 7.4

220 7.6 25,800 7.4

230 8.3 28,200 7.4

240 9.0 30,700 7.4

208 9.4 32,000 7.4

220 10.5 35,800 7.4

230 11.5 39,200 7.4

240 12.5 42,600 7.4

208 11.3 38,400 7.4

220 12.6 43,000 7.4

230 13.5 47,000 7.4

240 15.0 51,200 7.4

208 15.0 51,200 7.4

220 16.8 57,300 7.4

230 18.4 62,700 7.4

240 20.0 68,200 7.4

208 18.8 64,100 7.4

220 21.0 71,700 7.4

230 23.0 78,300 7.4

240 25.0 85,300 7.4

208 6.0 20,500 7.4

220 6.7 22,900 7.4

230 7.3 25,100 7.4

240 8.0 27,300 7.4

208 7.5 25,600 7.4

220 8.4 28,700 7.4

230 9.2 31,400 7.4

240 10.0 34,100 7.4

208 11.3 38,400 7.4

220 12.6 43,000 7.4

230 13.5 47,000 7.4

240 15.0 51,200 7.4

208 15.0 51,200 7.4

220 16.8 57,300 7.4

230 18.4 62,700 7.4

240 20.0 68,200 7.4

208 18.8 64,100 7.4

220 21.0 71,700 7.4

230 23.0 78,300 7.4

240 25.0 85,300 7.4

27 - - - - - -

4

30 - - - - - -

28 - - - - - -

4

30 - - - - - -

29 - - - - - -

4

30 - - - - - -

30 - - - - - -

4

30 - - - - - -

32 - - - - - 35 - - - - - -

33 - - - - - 35 - - - - - -

34 - - - - - 35 - - - - - -

35 - - - - - -

4

40 - - - - - -

36 - - - - - 40 - - - - - -

38 - - - - - 40 - - - - - -

39 - - - - - 40 - - - - - -

41 - - - - - -

4

45 - - - - - -

45 - - - - - 50 - - - - - -

47 - - - - - 50 - - - - - -

49 - - - - - 50 - - - - - -

51 - - - - - -

4

60 - - - - - -

50 - - - - - 60 - - - - - -

52 - - - - - 60 - - - - - -

54 - - - - - 60 - - - - - -

56 - - - - - 60 - - - - - -

28 38 - - 30

4

40 - - -

29 40 - - 30

4

40 - - -

30 42 - - 30 45 - - -

31 44 - - -

4

35

45 - - -

32 45 - - 35

4

45 - - -

33 48 - - 35

4

50 - - -

34 50 - - 35

4

50 - - -

35 52 - - -

4

40

60 - - -

50 50 - - -

4

50

4

50 - - -

52 53 - - 60 60 - - -

54 55 - - 60 60 - - -

56 57 - - 60 60 - - -

47

49

38

40

38

40

4

4

50

50

4

40

4

40

4

40

4

40

51 42 42 60 45 45

53 44 44 60 45 45

30 - - - - - 35 - - - - - -

31 - - - - - 35 - - - - - -

32 - - - - - 35 - - - - - -

33 - - - - - 35 - - - - - -

35 - - - - - 40 - - - - - -

37 - - - - - 40 - - - - - -

38 - - - - - 40 - - - - - -

39 - - - - - 40 - - - - - -

48 - - - - - 50 - - - - - -

51 - - - - - -

4

60 - - - - - -

52 - - - - - -

4

60 - - - - - -

54 - - - - - -

4

60 - - - - - -

35 26 - - -

4

40

37 28 - - -

4

40

38 29 - - -

4

40

4

30 - - -

4

30 - - -

4

30 - - -

39 30 - - -

4

40

35 - - -

42 33 - - -

4

45

4

35 - - -

44 34 - - -

4

45

4

35 - - -

45 36 - - 50 40 - - -

47 38 - - 50 40 - - -

100

105

109

113

77

81

84

88

66

69

72

75

- - -

- - -

- - -

- - -

122

129

135

141

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

62

65

67

70

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

75

78

81

84

1

3

NOTE - Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps.

2

Electric heater capacity only - does not include additional blower motor heat capacity.

4

Amps shown are for blower motor only.

Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

Bold text indicates that the circuit breaker on “CB” circuit breaker models must be replaced with size noted. See Table on Page 6.

5

HACR type circuit breaker or fuse.

70

70

70

70

- - -

- - -

- - -

- - -

80

80

90

90

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

80

90

90

90

100

125

125

125

70

70

80

80

- - -

- - -

- - -

- - -

125

150

150

150

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

CBX32MV / Page 17

ELECTRIC HEAT DATA - CBX32MV-068

Volts

Input kW

Input

1

Btuh

Input

2

Blower

Motor

Full

Load

Amps

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

Ckt 1 Ckt 2 Ckt 3 Ckt 1 Ckt 2 Ckt 3

Single Point

Power Source

3

Minimum

Circuit

Ampacity

5

Maximum

Overcurrent

Protection

SINGLE PHASE

5 kW

4 lbs.

6 kW

4 lbs.

8 kW

5 lbs.

9 kW

5 lbs.

12.5 kW

10 lbs.

15 kW

12 lbs.

20 kW

19 lbs.

25 kW

19 lbs.

ECB40-5 (34W87)

Terminal Block

ECB40-5CB

(34W90)

35A Circuit breaker

ECB40-6

(34W88)

Terminal Block

ECB40-6CB (34W91)

40A Circuit breaker

ECB40-8 (34W89)

Terminal Block

ECB40-8CB (34W92)

50A Circuit breaker

ECB40-9CB

(34W93)

60A Circuit breaker

ECB40-12.5CB

(34W94)

(1) 30A and

(1) 45A Circuit breaker

ECB40-15CB (34W95)

(1) 35A and

(1) 60A Circuit breaker

ECB40-20CB

(2) 60A Circuit breaker

ECB40-25CB

(34W96)

(34W97)

(1) 60A and

(2) 45A Circuit breaker

THREE PHASE

8 kW

5 lbs.

10 kW

6 lbs.

15 kW

12 lbs.

20 kW

19 lbs.

25 kW

19 lbs.

ECB40-8 (34W98)

Terminal block

ECB40-10 (34W99)

Terminal block

ECB40-15CB

(35W00)

50A Circuit breaker

ECB40-20CB (35W01)

(2) 35A Circuit breaker

ECB40-25CB

(35W02)

(1) 50A and

(1) 40A Circuit breaker

1

1

1

2

2

2

2

3

1

1

1

2

2

208 3.8 12,800 7.4

220 4.2 14,300 7.4

230 4.6 15,700 7.4

240 5.0 17,100 7.4

208 4.5 15,400 7.4

220 5.0 17,100 7.4

230 5.5 18,800 7.4

240 6.0 20,500 7.4

208 6.0 20,500 7.4

220 6.7 22,900 7.4

230 7.3 25,100 7.4

240 8.0 27,300 7.4

208 6.8 23,100 7.4

220 7.6 25,800 7.4

230 8.3 28,200 7.4

240 9.0 30,700 7.4

208 9.4 32,000 7.4

220 10.5 35,800 7.4

230 11.5 39,200 7.4

240 12.5 42,600 7.4

208 11.3 38,400 7.4

220 12.6 43,000 7.4

230 13.5 47,000 7.4

240 15.0 51,200 7.4

208 15.0 51,200 7.4

220 16.8 57,300 7.4

230 18.4 62,700 7.4

240 20.0 68,200 7.4

208 18.8 64,100 7.4

220 21.0 71,700 7.4

230 23.0 78,300 7.4

240 25.0 85,300 7.4

208 6.0 20,500 7.4

220 6.7 22,900 7.4

230 7.3 25,100 7.4

240 8.0 27,300 7.4

208 7.5 25,600 7.4

220 8.4 28,700 7.4

230 9.2 31,400 7.4

240 10.0 34,100 7.4

208 11.3 38,400 7.4

220 12.6 43,000 7.4

230 13.5 47,000 7.4

240 15.0 51,200 7.4

208 15.0 51,200 7.4

220 16.8 57,300 7.4

230 18.4 62,700 7.4

240 20.0 68,200 7.4

208 18.8 64,100 7.4

220 21.0 71,700 7.4

230 23.0 78,300 7.4

240 25.0 85,300 7.4

32 - - - - - 35 - - - - - -

33 - - - - - 35 - - - - - -

34 - - - - - 35 - - - - - -

35 - - - - - -

4

40 - - - - - -

36 - - - - - 40 - - - - - -

38 - - - - - 40 - - - - - -

39 - - - - - 40 - - - - - -

41 - - - - - -

4

45 - - - - - -

45 - - - - - 50 - - - - - -

47 - - - - - 50 - - - - - -

49 - - - - - 50 - - - - - -

51 - - - - - -

4

60 - - - - - -

50 - - - - - 60 - - - - - -

52 - - - - - 60 - - - - - -

54 - - - - - 60 - - - - - -

56 - - - - - 60 - - - - - -

28 38 - - 30

4

40 - - -

29 40 - - 30

4

40 - - -

30 42 - - 30 45 - - -

31 44 - - -

4

35

45 - - -

32 45 - - 35

4

45 - - -

33 48 - - 35

4

50 - - -

34 50 - - 35

4

50 - - -

35 52 - - -

4

40

60 - - -

50 50 - - -

4

50

4

50 - - -

52 53 - - 60 60 - - -

54 55 - - 60 60 - - -

56 57 - - 60 60 - - -

4

40

47 38 38

4

50

49 40 40

4

50

4

40

4

4

40

40

51 42 42 60 45 45

53 44 44 60 45 45

30 - - - - - 35 - - - - - -

31 - - - - - 35 - - - - - -

32 - - - - - 35 - - - - - -

33 - - - - - 35 - - - - - -

35 - - - - - 40 - - - - - -

37 - - - - - 40 - - - - - -

38 - - - - - 40 - - - - - -

39 - - - - - 40 - - - - - -

48 - - - - - 50 - - - - - -

51 - - - - - -

4

60 - - - - - -

52 - - - - - -

4

60 - - - - - -

54 - - - - - -

4

60 - - - - - -

35 26 - - -

4

40

37 28 - - -

4

40

38 29 - - -

4

40

44 34 - - -

4

45

4

30 - - -

4

30 - - -

4

30 - - -

39 30 - - -

4

40

35 - - -

42 33 - - -

4

45

4

35 - - -

4

35 - - -

45 36 - - 50 40 - - -

47 38 - - 50 40 - - -

100

105

109

113

122

129

135

141

77

81

84

88

66

69

72

75

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

62

65

67

70

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

75

78

81

84

1

3

NOTE - Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps.

2

Electric heater capacity only - does not include additional blower motor heat capacity.

4

Amps shown are for blower motor only.

Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.

Bold text indicates that the circuit breaker on “CB” circuit breaker models must be replaced with size noted. See Table on Page 6.

5

HACR type circuit breaker or fuse.

70

70

70

70

- - -

- - -

- - -

- - -

80

80

90

90

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

100

125

125

125

125

150

150

150

80

90

90

90

70

70

80

80

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

CBX32MV / Page 18

DIMENSIONS - INCHES (MM) UPFLOW

3/4

(19)

3/4

(19)

11-1/16 (281)

D

SUPPLY

OPENING

3/4

(19)

DETAIL OF PIPING PLATE

1-1/8 (29)

SUCTION LINE

LINE VOLTAGE

(Top and Left Side)

INLETS

(Top and

Right Side)

TOP VIEW

B C

3-1/2 (89)

AIR FLOW

G

OPTIONAL

ELECTRIC

(Field

Installed)

BLOWER

Note − Units are shipped in one piece but may be disassembled into two separate sections for ease of installation.

A

PIPING

PLATE

H

5/8

(16)

Return Air

F

F R O N T V I E W

5/8

(16)

FILTER

ACCESS

SUCTION

LINE

LIQUID

LINE

FILTER

1

(25)

COIL

Return Air

S I D E

E

V I E W

5/8

(16)

Model

No.

F

G

D

E

H

A

B

C

CBX32MV-018/024 CBX32MV-024/030 inch

45-1/4

16-1/4

20-5/8

14-3/4

19

15

24-5/8

20-5/8

mm

1149

413

524

375

483

381

625

524

inch

49-1/4

21-1/4

20-5/8

19-3/4

19

20

24-5/8

24-5/8

mm

1251

540

524

502

483

508

625

625

CX32MV-036 inch

51

21-1/4

22-5/8

19-3/4

21

20

26-3/4

24-5/8

mm

1295

540

878

502

533

508

640

625

CBX32MV-048

CBX32MV-060 inch mm

58-1/2 1486

21-1/4 540

24-7/8

19-3/4

23

20

27-7/8

30-5/8

625

502

584

508

708

778

CBX32MV-068 inch

65

21-1/4

26-5/8

19-3/4

25

20

32-3/8

32-5/8

mm

1651

540

675

502

635

508

822

829

CBX32MV / Page 19

DIMENSIONS - INCHES (MM) DOWNFLOW

DETAIL OF PIPING PLATE

1-1/8 (29)

SUCTION LINE

5/8

(16)

5/8

(16)

E

F

RETURN

OPENING

1 (25)

1

(25)

TOP VIEW

3-1/2 (89)

B

FILTER

ACCESS

C

PIPING

PLATE

H

FILTER

SUCTION

LINE

COIL

AIR FLOW

G

A

OPTIONAL

ELECTRIC

HEAT

Installed)

LOW VOLTAGE

(Right Side)

BLOWER

5/8

(16)

Supply Air

D

Supply Air

3/4

(19)

F R O N T V I E W S I D E

11-1/16

V I E W

NOTE - Units are shipped in one piece but may be disassembled into two separate sections for ease of installation.

A

B

C

D

E

F

G

H

Model

No.

CBX32MV-018/024 CBX32MV-024/030 inch

45-1/4

16-1/4

20-5/8

14-3/4

19

15

24-5/8

20-5/8

mm

1149

413

524

375

483

381

625

524

inch

49-1/4

21-1/4

20-5/8

19-3/4

19

20

24-5/8

24-5/8

mm

1251

540

524

502

483

508

625

625

CX32MV-036 inch

51

21-1/4

22-5/8

19-3/4

21

20

26-3/4

24-5/8

mm

1295

540

878

502

533

508

640

625

CBX32MV-048

CBX32MV-060 inch mm

58-1/2 1486

21-1/4

24-7/8

540

625

19-3/4

23

20

27-7/8

30-5/8

502

584

508

708

778

CBX32MV-068 inch

65

21-1/4

26-5/8

19-3/4

25

20

32-3/8

32-5/8

mm

1651

540

675

502

635

508

822

829

CBX32MV / Page 20

DIMENSIONS - INCHES (MM) HORIZONTAL

RIGHT-HAND AIR DISCHARGE

DETAIL OF PIPING PLATE

FILTER

SUCTION

LINE

5/8

(16)

1-1/8 (29)

LIQUID

LINE

COIL

BLOWER C

Note − Units are shipped in one piece but may be disassembled into two separate sections for ease of installation.

H

SUCTION LINE

OPTIONAL ELECTRIC HEAT

(Field Installed)

TOP VIEW

A

G

5/8

(16)

LINE VOLTAGE

INLETS

(Top and Right Side)

11-1/16

(281)

3/4

(19)

3/4

(19)

5/8

(16)

E

F

RETURN

AIR

OPENING

1

(25)

PIPING

PLATE

AIR

FLOW

B AIR

OPENING

D

END VIEW

FILTER

ACCESS

F R O N T V I E W

LOW VOLTAGE INLETS

(Bottom and Right Side)

E N D V I E W

3/4

(19)

LEFT-HAND AIR DISCHARGE

FILTER

DETAIL OF PIPING PLATE

C BLOWER

COIL

3/4

(19)

Note − Units are shipped in one piece but may be disassembled into two separate sections for ease of installation.

3/4

(19)

11-1/16

(281)

LOW VOLTAGE

INLETS

5/8

(16)

OPTIONAL ELECTRIC HEAT

(Field Installed)

SUCTION LINE

TOP VIEW

A

G H

1-1/8 (29)

SUCTION

LINE

3/4

(19)

D

SUPPLY

AIR

OPENING

FILTER

ACCESS

B

AIR

FLOW

PIPING

PLATE

1

(25)

RETURN

OPENING

E

F

5/8

(16)

END VIEW

LINE VOLTAGE INLETS

(Bottom and Left Side)

Model

No.

G

H

E

F

C

D

A

B

CBX32MV-018/024 CBX32MV-024/030 inch

45-1/4

16-1/4

20-5/8

14-3/4

19

15

24-5/8

20-5/8

mm

1149

413

524

375

483

381

625

524

inch

49-1/4

21-1/4

20-5/8

19-3/4

19

20

24-5/8

24-5/8

mm

1251

540

524

502

483

508

625

625

FRONT VIEW

CX32MV-036 inch

51

21-1/4

22-5/8

19-3/4

21

20

26-3/4

24-5/8

mm

1295

540

878

502

533

508

640

625

CBX32MV-048

CBX32MV-060 inch

58-1/2

21-1/4

24-7/8

19-3/4

23

20

27-7/8

30-5/8

mm

1486

540

625

502

584

508

708

778

END VIEW

5/8

(16)

CBX32MV-068 inch

65

21-1/4

26-5/8

19-3/4

25

20

32-3/8

32-5/8

mm

1651

540

675

502

635

508

822

829

CBX32MV / Page 21

DIMENSIONS - INCHES (MM)

AIR FLOW

PIPING

PLATE

AIR FLOW

B

B

AIR FLOW

RIGHT-HAND AIR FLOW

B

A

5/8

(16)

AIR FLOW

5/8

(16)

5/8

(16)

A

LEFT-HAND AIR FLOW

A

Model

No.

in.

A mm

B in.

mm

CBX32MV-018/024 45-1/4 1149 16-1/4 413

CBX32MV-024/030 49-1/4 1251 21-1/4 540

CBX32MV-036

CBX32MV-048

CBX32MV-060

CBX32MV-068

51 1295 21-1/4 540

58-1/2 1486 21-1/4 540

65 1651 21-1/4 540

B

PIPING

PLATE

AIR FLOW

UPFLOW DOWNFLOW

A

5/8

(16)

SIDE RETURN UNIT STAND

(Upflow Only)

21-1/4

-024/030 thru -060

- 21-1/4 (540)

20 (508) to

ALL UNITS

CBX32MV / Page 22

DIMENSIONS - INCHES (MM)

DOWNFLOW COMBUSTIBLE FLOORING BASE

1-5/8

(41)

Catalog No. - 34J72

1-5/8

(41)

11-3/8

(289)

15

(381)

SUPPLY

OPENING

23-1/4

(591)

1-5/8

(41)

1-5/8 (41)

TOP VIEW

20

(508)

11-3/8

(289)

23−1/4

(591)

Catalog No. − 44K15

5/8

(16)

1-5/8

(41)

TOP VIEW

A

22-1/8 (562)

13-1/2 (343)

Opening

SIDE VIEW

3 (76)

Break off extended width at pre-perforated line to fit specific air handler application.

NOTE - Width of base includes an additional 2 in. (51 mm) for air handler positioning adjustment.

5/8

(16)

1-5/8 (41)

13-1/2 (343)

Opening

SUPPLY AIR

OPENING

SIDE VIEW

3 (76)

1

No modification required.

Model

No.

A

B

C

D

E

CBX32MV-018/024 CBX32MV-024/030 CBX32MV-036 in.

22-1/8

- - -

- - -

- - -

- - -

mm

562

- - -

- - -

- - -

- - -

in.

- - -

22-5/8

- - -

- - -

- - -

mm

- - -

575

- - -

- - -

- - -

in.

- - -

- - -

24-5/8

- - -

- - -

mm

- - -

- - -

625

- - -

- - -

CBX32MV-048

CBX32MV-060 in.

- - -

- - -

- - -

26-5/8

- - -

mm

- - -

- - -

- - -

676

- - -

CBX32MV-068 in.

- - -

- - -

- - -

- - -

28-5/8

mm

- - -

- - -

- - -

- - -

727

CBX32MV / Page 23

REVISIONS

Sections

Optional Accessories

Description of Change

Added icomfort Wi-Fi™ Thermostat.

Removed icomfort Touch

®

Communicating Thermostat (product discontinued).

Visit us at www.lennox.com

For the latest technical information, www.lennoxdavenet.com

Contact us at 1-800-4-LENNOX

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.

Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.

Installation and service must be performed by a qualified installer and servicing agency. ©2012 Lennox Industries, Inc.