User Manual
Power
Distribution
Unit
4241 12th Ave E #400,
Shakopee, MN 55379
1-877-297-6937
www.CPSww.com
K01-0000083-00
Table of Contents
Model List ......................................................1
PDU Naming Convention ............................. 1
Package Contents ........................................ 2
Safety Precautions ....................................... 2
Installation .................................................... 3
Horizontal Installation ....................... 3
Vertical Installation with Brackets ... 4
Vertical Installation Keyhole Mounts (0U models only) ... 5
Cord Retention Tray installation ...... 5
Meter Configuration .......................... 5
Electrical Installation ........................ 6
Troubleshooting ........................................... 6
Product Features
Technical Specification ............................... 7
Basic Series (1U 20A)......................... 7
Basic Series (1U 30A)......................... 8
Basic Series (0U 10A)......................... 9
Basic Series (0U 20A)........................ 10
Basic Series (0U 30A)........................ 11
Metered Series (0U 20A) .................... 12
Metered Series (0U 30A) .................... 13
Warranty & Service .......................................14
Model List:
Package Contents
Basic Series:
PDU20BHVT8R
PDU20BHVT10R
PDU20BHVT12R
PDU20BHVIEC8R
PDU20BHVIEC10R
PDU20BHVIEC12R
PDU20BHVIEC12Ra
PDU30BT8F8R
PDU30BT10F10R
PDU30BHVT8R
PDU30BHVT10R
PDU30BHVT12R
Basic Series (0U):
PDU (1)
Cord Retention Tray
(1/2/3/4 pcs - varies by model)
Mounting Brackets
PDU10BVHVIEC16F
PDU10BVHVIEC20F
PDU20BVHVT16F
PDU20BVHVT20F
PDU20BVHVT24F
PDU20BVHVT32F
PDU20BVHVT38F
PDU20BVHVIEC16F
PDU20BVHVIEC20F
PDU20BVHVIEC24F
PDU20BVHVIEC32F
PDU20BVHVIEC38F
PDU30BVT14F
PDU30BVT16F
PDU30BVT20F
PDU30BVT28F
PDU30BVT32F
PDU30BVHVT16F
PDU30BVHVT20F
PDU30BVHVT32F
PDU30BVHVT38F
Horizontal Installation
Used (1 set)
Vertical Installation Vertical Mounting Brackets (1 set)
Used (1 set)
(for 0U models only)
Cord Retention Tray
Mounting Screws M3 X 6
(4/8/12/16 pcs - varies by model)
Bracket Mounting
Screws M4 X 8 (4pcs)
Metered Series (0U):
PDU20MVHVT20F
PDU20MVHVT30F
PDU20MVHVT38F
PDU20MVHVIEC24F
PDU20MVHVIEC30F
PDU20MVHVIEC38F
PDU30MVT24F
PDU30MVT32F
PDU30MVHVT20F
PDU30MVHVT30F
PDU30MVHVT38F
Keyhole Mounting Pegs (2pcs)
with Screws M4 X 8 (2pcs)
(for 0U models only)
Cord Retainer Clips (8/10/12/14/16/
20/24/30/32/38 pcs - varies by model)
for Cord Retention Tray
Ground Screw M5 X 6 (1 pcs)
PDU Naming Convention:
Documentation:
PDU XX M V HV T F R NET
1
2
3
4
5
6
7
Use
r Man
ual
Dist Power
ribu
tion
Unit
8
User Manual
Amperage – 15A, 20A, 30A
B: =Basic
M: =Metered
SW: = Switched
NULL: =Horizontal
V:= Vertical
3. Rack Space:
NULL: =120V HV:= High Voltage – 200V to 230V
4. Input Voltage:
NULL: =NEMA 5-15P / 5-20P
5. Plug Type:
T: = Twist (NEMA L5-L6 Plug)
IEC:= (IEC C14/C20)
Number of Outlets followed by F – Example 8F
6. Outlet Number Front
Number of Outlets followed by R – Example 8R
7. Outlet Number Rear
8. Network Management NET
1. Amperage:
2. Series:
Check
Product
Registration
Card
Product Registration Card
Before using, please check to ensure the package contains all the
items shown above. If there are missing parts please contact
CyberPower technical support at www.CPSww.com or call 1-877297-6937.
Safety Precautions Read the following before installing or operating
the Power Distribution Unit (PDU):
1. Use only the supplied hardware to attach the mounting brackets.
2. The PDU must only be plugged into a three-wire, grounded outlet on a
circuit protected by a fuse or circuit breaker. Connection to any other type
of power outlet may result in a shock hazard.
3. Do not use extension cords or adapters with this PDU.
4. Never install a PDU, or associated wiring or equipment, during a lightning
storm.
5. Check that the power cord, plug, and socket are in good condition.
6. The socket-outlet shall be installed near the equipment and shall be easily
accessible.
7. CAUTION! To prevent the risk of fire or electric shock, this PDU should be
installed in a temperature and humidity controlled indoor area free of
conductive contaminants. Do not install this PDU where excessive
moisture or heat is present..
1
For information on Cyberpower products, visit www.CPSww.com
For information on Cyberpower products, visit www.CPSww.com
2
Installation
Vertical Installation with Brackets
Horizontal Installation (1U models only)
Step 1 – Mounting bracket installation
Step 1 – Mounting bracket installation
Install the screws (M4 X 8) in holes diagonal from each other.
Install the screws (M4 X 8) in holes diagonal from each other.
Step 2 – PDU Mounting
Step 2 – PDU Mounting
Install the PDU using fasteners compatible with the rack.
Vertical Installation with Brackets (0U models only)
Step 1 – Mounting bracket installation
Install the PDU using fasteners compatible with the rack.
Attach the Vertical Mounting Brackets to the PDU with the 4 supplied
Bracket Mounting Screws (M4 X 8).
Step 2 – PDU Mounting
Install the PDU using fasteners compatible with the rack.
3
For information on Cyberpower products, visit www.CPSww.com
For information on Cyberpower products, visit www.CPSww.com
4
Vertical Installation with Keyhole Mounts (0U Models)
Electrical Installation
Step 1 – Keyhole Mount installation
Step 1 – Receptacle evaluation
Ensure that the plug type of your PDU unit (e.g. NEMA 5-15P, NEMA 520P, NEMA L5-30P) matches the wall receptacle type that you are using.
CAUTION!!
PDU must be plugged into a three-wire, grounded wall receptacle only.
The wall receptacle must also be connected to an appropriate branch
circuit/main with fuse or circuit breaker protection. Connection to any
other type of wall receptacle may result in a shock hazard.
Step 2 – Plug the PDU into the wall receptacle
Attach the Keyhole Mounting Pegs to the PDU with the 2 supplied
Bracket Mounting Screws (M4 X 8).
Step 2 – PDU Mounting
Step 3 – Attach equipment
Before attaching equipment, it is important to calculate the total load that you
will be placing on the PDU. It is extremely important not to exceed the PDU's
maximum current load (as outlined in the Specifications section). In order to
determine your total load, simply add up the amperage of your devices and
ensure that it does not exceed the unit’s capacity.
Align the the Keyhole Mounts to the Keyhole Slots on the rack.
Insert and slide down to lock firmly into place.
Cord Retention Tray installation
(Optional for both horizontal and vertical installations)
Attach the Cord Retention Tray to the PDU with the 4 supplied Cord
Retention Tray Mounting Screws (M3 X 6).
Troubleshooting
Problem
Possible Cause
PDU Outlets do not 1. Open breaker
provide power to
2. Loose power cord
connected
equipment
Amperage displayed 1. Overload
on Amperage Meter 2. Amperage meter is
damaged
exceeds the unit’s
capability (Metered
type only)
Circuit breaker has
tripped
1. Sustained overload
2. Excessive ambient or
internal temperatures.
3. Faulty breaker
Solution
Reset Breaker check if
plug is completely
connected.
If the problem remains
contact tech support.
The meter will flash
when overloaded.
Reduce the load on the
PDU until the overload
is gone.
If the problem remains
contact tech support.
Reset Breaker.
If the problem remains
contact tech support.
Attach the Cord Retainer Clips to the Cord Retention Tray.
Meter Configuration
!
Note
Depending on installation method (vertical or horizontal),
the LED Meter may need to be rotated, before installation,
for proper orientation.
Use a screwdriver to gently remove the LED Meter. Rotate the LED Meter
90 degrees, and insert back into the PDU.
5
For information on Cyberpower products, visit www.CPSww.com
For information on Cyberpower products, visit www.CPSww.com
6
Basic Series ( 1U 20A )
Basic Series ( 1U 30A )
Product Features
Product Features
Front View
Front View
Normal Type
R
R
BANK1
BANK2
BANK1
A
A
A. Mounting Bracket
B
C
A. Mounting Bracket
Back View
B. LED Indicators
C. Front Bank 1 Outlets
High Voltage Type
Twist Type
R
BANK1
BANK2
A
B
A. Mounting Bracket
A
G
B
C
A. Mounting Bracket
B. Rear Outlets (IEC 320 C13)
C. Rear Outlets (IEC 320 C19)
D. Circuit Breaker
D
E
F
G
B. LED Indicators
Back View
Normal Type
E. External Site Ground
F. AC Power Cord
G. Cord Retention Tray
Screw Holes
BANK2
A
IEC Type
G B
C
D
E
F
G
A.Mounting Bracket B.Circuit Breaker (Bank 1) C.Rear Bank 2 Outlets D.External Site
Ground E.Circuit Breaker (Bank 2) F.AC Power Cord G.Cord Retention Tray Screw Holes
High Voltage Type
BANK2
A
F
B
C
D
E
D. External Site Ground
E. AC Inlet (IEC 320 C20)
F. Cord Retention Tray
Screw Holes
A. Mounting Bracket
B. Rear Outlets (IEC 320 C13)
C. Circuit Breaker
Technical Specifications
Model Name
A
H
B
C
D
PDU20BHVIEC8R
PDU20BHVIEC10R
PDU20BHVIEC12R
PDU20BHVIEC12Ra
PDU20BHVT8R
PDU20BHVT10R
PDU20BHVT12R
Model Name
Voltage
100 ~ 125 V
200~230V
Max Current
30 A
Regulatory Derated
Input Current
16 A
Regulatory Derated
Input Current
24A
16 A
Circuit Breaker
Circuit Breaker
NEMA L6-20P
IEC 320 C20
10 f t
Power Cord Length
Plug Type
Power Cord Length
Output
200~230V
20 A
IEC 320 C13(8)
IEC 320 C13(10)
IEC 320 C13(12)
IEC 320 C19(2)/C13(10)
IEC 320 C19(2)/C13(6)
IEC 320 C19(2)/C13(8)
IEC 320 C13(12)
Voltage
Outlet Type(Quantity)
N/A
LED Indicators
Meter Readout
N/A
Meter Readout
17.5" x 1.5" x 1.75" / 44.5 x 3.81 x 4.45 cm
Environmental
Warranty
100~125 V
200~230V
30 A
IEC 320 C19(2)/C13(6)
IEC 320 C19(2)/C13(8)
IEC 320 C13(12)
NEMA 5-20R(16)
NEMA 5-20R(20)
Bank1(GREEN)
Bank2(GREEN)
N/A
Dimension (WxDxH)
17.5"x2.25"x1.75" / 44.5x5.72x4.45 cm
17.5"x1.5"x1.75" / 44.5x3.81x4.45 cm
Environmental
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
Certifications
10 f t
Physical
Physical
Temperature
12 f t
Indicators
LED Indicators
Altitude
16 A x 2
NEMA L6-30P
Max Current
Indicators
Humidity
20 A x 2
NEMA L5-30P
Output
Max Current
Dimension (WxDxH)
H
PDU30BHVT8R
PDU30BHVT10R
PDU30BHVT12R
PDU30BT8F8R
PDU30BT10F10R
20 A
Outlet Type(Quantity)
G
A.Mounting Bracket B.Bank 2 Outlets C.Bank 1 Outlets D.Circuit Breaker (Bank 2)
E.Circuit Breaker (Bank 1) F.External Site Ground G.AC Power Cord
H.Cord Retention Tray Screw Holes
Max Current
Voltage
F
Input
200~230V
Voltage
Plug Type
E
Technical Specifications
Input
7
BANK1
F
Humidity
Altitude
Temperature
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
ETL (test followed UL 60950-1 )
RoHS
Lifetime
For information on Cyberpower products, visit www.CPSww.com
Certifications
Warranty
ETL (test followed UL 60950-1 )
RoHS
Lifetime
For information on Cyberpower products, visit www.CPSww.com
8
Basic Series ( 0U 10A )
Product Features
Front View
A
B
C
E
Basic Series ( 0U 20A )
Product Features
Front View
Back View
A. AC Inlet
(IEC 320 C14)
B. Circuit Breaker
C. External Site Ground
D. Front Outlets
E. Cord Retention Tray
Screw Holes
A
A. Bracket Screw Hole
B. Keyhole Mount Peg
Screw Holes
Back View
A
A
B
B
C
F
B
Twist Type:
A. AC Power Cord
B. Circuit Breaker
C. External Site Ground
D. Front Outlets
E. Front Outlets
F. Cord Retention Tray
Screw Holes
A. Bracket Screw Hole
B. Keyhole Mount Peg
Screw Holes
C
F
D
D
F
F
F
F
A
B
D
B
A
E
E
F
PDU10BVHVIEC16F
PDU10BVHVIEC20F
F
Model Name
PDU20BVHVT16F
PDU20BVHVT20F
PDU20BVHVT24F
PDU20BVHVT32F
PDU20BVHVT38F
PDU20BVHVIEC16F
PDU20BVHVIEC20F
PDU20BVHVIEC24F
PDU20BVHVIEC32F
PDU20BVHVIEC38F
200~230V
200~230V
Voltage
Max Current
10 A
Max Current
20 A
Input Current
Circuit Breaker
Plug Type
10 A
10 A
Regulatory Derated
Input Current
16 A
Power Cord Length
Output
Voltage
Max Current
Outlet Type(Quantity)
IEC C14
10 f t
200~230V
10 A
IEC 320 C13(16)
IEC 320 C19(4)/C13(16)
LED Indicators
N/A
N/A
Physical
Dimension (WxDxH)
1.75"x1.5"x24" / 4.45x3.81x60.96 cm
1.75"x1.5"x36" / 4.45x3.81x91.44 cm
Altitude
Temperature
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
Certifications
Warranty
ETL (test followed UL 60950-1 )
RoHS
Lifetime
Voltage
Max Current
IEC 320 C20
10 f t
200~230V
20 A
IEC 320 C13(16)
IEC 320 C19(4)/C13(16)
IEC 320 C19(4)/C13(20)
IEC 320 C19(8)/C13(24)
IEC 320 C19(8)/C13(30)
Indicators
LED Indicators
N/A
Meter Readout
N/A
Physical
1.75" x 1.5" x 24" / 4.45 x 3.81 x 60.96 cm
1.75" x 1.5" x 36" / 4.45 x 3.81 x 91.44 cm
1.75" x 1.5" x 48" / 4.45 x 3.81 x 121.92cm
1.75" x 1.5" x 60" / 4.45 x 3.81 x 152.40 cm
1.75" x 1.5" x 70" / 4.45 x 3.81 x 177.80 cm
Environmental
Humidity
Altitude
Temperature
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
Certifications
Warranty
For information on Cyberpower products, visit www.CPSww.com
NEMA L6-20P
Output
Dimension (WxDxH)
Environmental
Humidity
Plug Type
Outlet Type(Quantity)
Meter Readout
16 A
Circuit Breaker
Power Cord Length
Indicators
9
A
Input
Input
Voltage
B
E
Technical Specifications
Technical Specifications
Model Name
High Voltage Type:
A. AC Inlet
(IEC 320 C20)
B. Circuit Breaker
C. External Site Ground
D. Front Outlets
E. Front Outlets
F. Cord Retention Tray
Screw Holes
ETL (test followed UL 60950-1 )
RoHS
Lifetime
For information on Cyberpower products, visit www.CPSww.com
10
Basic Series ( 0U 30A )
Product Features
Front View
A
B
F
Front View
A
A
B
C
E
Product Features
Back View
A
D
Meter Series ( 0U 20A )
C
Normal Type:
A. AC Power Cord
B. External Site Ground
C. Circuit Breaker
(Bank 1)
D. Circuit Breaker
(Bank 2)
E. Cord Retention Tray
Screw Holes
F. Front Outlets(Bank1)
G. Front Outlets(Bank2)
D
G
B Normal Type:
A
A
B
B
Twist Type:
A. AC Power Cord
B. Circuit Breaker
G C. External Site Ground
D. Front Outlets
E . Meter Readout
F . Front Outlets
G . Cord Retention Tray
C
B
A. AC Power Cord
B. Bracket Screw Hole
C C. Keyhole Mount Peg
Screw Holes
Back View
C
A. Bracket Screw Hole
B. Keyhole Mount Peg
Screw Holes
C
G
A
Screw Holes
E
D
D
G
G
E
E
G
G
B
E
G
G
G
C
B
C
E
F
High Voltage Type:
A. AC Power Cord
B. Circuit Breaker
(Bank 1)
C. Circuit Breaker
(Bank 2)
D . External Site Ground
E . Front Outlets(Bank 1)
F . Front Outlets(Bank 2)
G . Cord Retention Tray
Screw Holes
High Voltage Type:
A. AC Power Cord
B. Bracket Screw Hole
C. Keyhole Mount Peg
Screw Holes
B
G
F
High Voltage Type:
A. AC Inlet
(IEC 320 C20)
B . Circuit Breaker
C . External Site Ground
D . Front Outlets
E . Meter Readout
F . Front Outlets
G . Cord Retention Tray
G
Technical Specifications
Model Name
G
PDU30BVT14F
PDU30BVT16F
PDU30BVT20F
PDU30BVT28F
PDU30BVT32F
PDU30BVHVT16F
PDU30BVHVT20F
PDU30BVHVT32F
PDU30BVHVT38F
100 ~ 125 V
200~230V
Model Name
PDU20MVHVT20F
PDU20MVHVT30F
PDU20MVHVT38F
PDU20MVHVIEC24F
PDU20MVHVIEC30F
PDU20MVHVIEC38F
Input
200~230V
Voltage
Max Current
30 A
Max Current
20 A
Regulatory Derated
Input Current
24A
Regulatory Derated
Input Current
16 A
Circuit Breaker
Plug Type
20 A x 2
16 A x 2
NEMA L5-30P
NEMA L6-30P
Power Cord Length
Voltage
Plug Type
NEMA L6-20P
IEC 320 C20
10 f t
Output
100 ~ 125 V
200~230V
30 A
Max Current
Outlet Type(Quantity)
16 A
Circuit Breaker
Power Cord Length
10 f t
Output
NEMA 5-20R(14)
NEMA 5-20R(16)
NEMA 5-20R(20)
NEMA 5-20R(28)
NEMA 5-20R(32)
Voltage
200~230V
Max Current
IEC 320 C13(16)
IEC 320 C19(4)/C13(16)
IEC 320 C19(8)/C13(24)
IEC 320 C19(8)/C13(30)
Indicators
Outlet Type(Quantity)
20 A
IEC 320 C19(4)/C13(16)
IEC 320 C19(6)/C13(24)
IEC 320 C19(8)/C13(30)
IEC 320 C19(4)/C13(20)
IEC 320 C19(6)/C13(24)
IEC 320 C19(8)/C13(30)
Indicators
LED Indicators
N/A
LED Indicators
N/A
Meter Readout
N/A
Meter Readout
Amperage
Physical
Dimension (WxDxH)
Physical
1.75"x2.25"x24" / 4.45x5.72x60.96 cm
1.75"x2.25"x36" / 4.45x5.72x91.44 cm
1.75"x2.25"x48" / 4.45x5.72x121.92cm
1.75"x2.25"x60" / 4.45x5.72x152.40 cm
1.75"x2.25"x70" / 4.45x5.72x177.80 cm
1.75"x1.5"x24" / 4.45x3.81x60.96 cm
1.75"x1.5"x36" / 4.45x3.81x91.44 cm
1.75"x1.5"x60" / 4.45x3.81x152.40 cm
1.75"x1.5"x70" / 4.45x3.81x177.80 cm
Environmental
Humidity
Altitude
Temperature
Certifications
Warranty
Dimension (WxDxH)
1.75" x 1.5" x 48" / 4.45 x 3.81 x 121.92 cm
1.75" x 1.5" x 60" / 4.45 x 3.81 x 152.40 cm
1.75" x 1.5" x 70" / 4.45 x 3.81 x 177.80 cm
Environmental
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
11
A
Technical Specifications
Input
Voltage
Screw Holes
B
F
Humidity
Altitude
Temperature
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
ETL (test followed UL 60950-1 )
RoHS
Lifetime
For information on Cyberpower products, visit www.CPSww.com
Certifications
Warranty
ETL (test followed UL 60950-1 )
RoHS
Lifetime
For information on Cyberpower products, visit www.CPSww.com
12
Product Registration
Metered Series (0U 30A)
Product Features
Front View
Thank you for purchasing a CyberPower product. Prompt product
registration entitles coverage under the Limited Warranty and also allows
the opportunity to be notified of product enhancements, upgrades, and
other announcements.
Back View
A
A A. AC Power Cord
A
B
B. Bracket Screw Hole
C. Keyhole Mount Peg
Screw Holes
B
C
C
D
D
E
F
Screw Holes
E
F
I
C
Hours of Operation: Monday – Friday, 8:00am – 5:00pm (CST)
Limited Warranty
Read the following terms and conditions carefully before using the
CyberPower PDU(the “Product”). By using the Product you consent to
be bound by and become a party to the terms and conditions of this
Limited Warranty (together referred to as this “Warranty”). If you do not
agree to the terms and conditions of this Warranty, you should return the
Product for a full refund prior to using it.
F
I
H
E
CyberPower Technical Support
Phone: 1-877-297-6937
Email: tech@cpsww.com
Web: www.CPSww.com
Mail: 4241 12th Avenue E, Suite 400 Shakopee, MN 55379
F. Front Outlets (Bank 1)
G. Meter Readout
(Bank 1)
H. Meter Readout
(Bank 2)
I. Front Outlets (Bank 2)
G
I
B
E
G
High Voltage Type:
A. AC Power Cord
B. Circuit Breaker (Bank 1)
C. Circuit Breaker (Bank 2)
D. External Site Ground
E. Front Outlets (Bank 1)
F. Meter Readout
(Bank 1)
G. Meter Readout
(Bank 2)
H. Front Outlets (Bank 2)
I . Cord Retention Tray
Who is Providing this Warranty?
CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited
Warranty.
C
H
What Does This Warranty Cover?
B
Screw Holes
E
This warranty covers defects in materials and workmanship in the
Product under normal use and conditions.
I
Technical Specifications
Model Name
What is the Period of Coverage?
PDU30MVHVT20F
PDU30MVHVT30F
PDU30MVHVT38F
PDU30MVT24F
PDU30MVT32F
Input
Voltage
100 ~ 125 V
200~230V
Max Current
30 A
Regulatory Derated
Input Current
24A
Circuit Breaker
Plug Type
16 A x 2
NEMA L5-30P
NEMA L6-30P
Power Cord Length
10 f t
100 ~ 125 V
Outlet Type(Quantity)
200~230V
30 A
Max Current
IEC 320 C19(4)/C13(16)
IEC 320 C19(6)/C13(24)
IEC 320 C19(8)/C13(30)
NEMA 5-20R(24)
NEMA 5-20R(32)
Indicators
LED Indicators
N/A
Meter Readout
2 Amperage
Physical
Dimension (WxDxH)
1.75"x2.25"x60" / 4.45x5.72x152.40 cm
1.75"x2.25"x70" / 4.45x5.72x177.80 cm
This Warranty is for as long as the original owner owns the Product.
Who Is Covered?
This warranty only covers the original purchaser.
Coverage ends if you sell or otherwise transfer the Product.
How Do You Get Service?
20 A x 2
Output
Voltage
Need Additional Help?
Feel free to contact our Tech Support department with installation,
troubleshooting, or general product questions.
I
Normal Type:
A. AC Power Cord
B. External Site Ground
C. Circuit Breaker (Bank 1)
D. Circuit Breaker (Bank 2)
E. Cord Retention Tray
Registration is quick and easy at www.cpsww.com/register.
1.75"x1.5"x48" / 4.45x3.81x121.92 cm
1.75"x1.5"x60" / 4.45x3.81x152.40 cm
1.75"x1.5"x70" / 4.45x3.81x177.80 cm
1. Call us at (877) 297-6937 or write to us at Cyber Power Systems
(USA), Inc., 4241 12th Ave. E., STE 400, Shakopee, MN 55379 or
send us an e-mail message at claims@cyberpowersystems.com
for instructions.
2. When you contact CyberPower, identify the Product, the Purchase
Date, and the item(s) of Connected Equipment. Have information
on all applicable insurance or other resources of recovery/payment
that are available to the Initial Customer and Request a Claim
Number.
3. You must provide a purchase receipt (or other proof of the original
purchase) and provide a description of the defect.
4. Pack and ship the product to CyberPower and, if requested, the
item(s) of Connected Equipment, a repair cost estimate for the
damage to the Connected Equipment, and all claim forms that
CyberPower provides to you. Show the Claim Number on the
shipping label or include it with the product. You must prepay all
shipping costs, you are responsible for packaging and shipment,
and you must pay the cost of the repair estimate.
What Will We Do To Correct Problems?
CyberPower will inspect and examine the Product.
Environmental
Humidity
Altitude
Temperature
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Safety Approvals
Certifications
Warranty
13
ETL (test followed UL 60950-1 )
RoHS
Lifetime
For information on Cyberpower products, visit www.CPSww.com
If the Product is defective in material or workmanship, CyberPower
will repair or replace it at CyberPower's expense, or, if CyberPower
is unable to or decides not to repair or replace the Product
(if defective) within a reasonable time, CyberPower will refund to you
the full purchase price you paid for the Product (purchase receipt
showing price paid is required).
Who Pays For Shipping?
We pay when we send items to you; you pay when you send items
to us.
For information on Cyberpower products, visit www.CPSww.com
14
What Are Some Things This Warranty Does Not Cover?
1. This Warranty does not cover any software that was damaged or
needs to be replaced due to the failure of the Product or any data
that is lost as a result of the failure or the restoration of data or
records, or the reinstallation of software.
2. This Warranty does not cover or apply to: misuse, modification,
operation or storage outside environmental limits of the Product or
the equipment connected to it, nor for damage while in transit or in
storage, nor if there has been improper operation or maintenance,
or use with items not designed or intended for use with the Product,
such as laser printers, appliances, aquariums, medical or life
support devices, etc.
What are the Limitations?
1. This Warranty does not apply unless the Product and the
equipment that was connected to it were connected to properly
wired and grounded outlets (including compliance with electrical
and safety codes of the most current electrical code), without the
use of any adapters or other connectors.
2. The Product must have been plugged directly into the power
source and the equipment connected to the Product must be
directly connected to the Product and not “daisy-chained” together
in serial fashion with any extension cords, another Product or
device similar to the Product, surge suppressor, or power tap.
Any such installation voids the Limited Warranty.
3. The Product and equipment connected to it must have been used
properly in a suitable and proper environment and in conformance
with any license, instruction manual, or warnings provided with the
Product and the equipment connected to it.
4. The Product must have been used at all times within the limitations
on the Product's VA capacity.
5. The sole and exclusive remedies of the Initial Customer are those
provided by this Warranty.
Contact Information
CyberPower Systems, Inc.
4241 12th Ave. East
Suite 400
Shakopee, MN 55379
Phone: (952) 403-9500
Toll-free: (877) 297-6937
CyberPower is the warrantor under this Limited Warranty.
You may also contact CyberPower on the web at CPSww.com.
15
For information on Cyberpower products, visit www.CPSww.com
For information on Cyberpower products, visit www.CPSww.com