I-42-EM-A

SERIES D

10W–42W RAPID START

4 PIN COMPACT LAMP

EMERGENCY LIGHTING EQUIPMENT

INSTRUCTION MANUAL

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.

CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C.

power is supplied to the unit.

2.

CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnecting the unit connector.

3.

CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the entire unit when necessary. The EPA certified RBRC ® Battery Recycling Seal indicates that IOTA

Engineering is voluntarily participating in an industry program to collect and recycle these batteries at the end of their useful life, when taken out of service in the United States or Canada. The RBRC program provides a convenient alternative to placing used Ni-Cad batteries into the trash or the municipal waste stream, which may be illegal in your area. Please call 1-800-822-8837 for information on Ni-Cad battery recycling and disposal bans/restrictions in your area. IOTA Engineering’s involvement in this program is part of our commitment to preserving our environment and conserving our natural resources.

4.

DO NOT USE OUTDOORS. The I-42-EM-A is for use with grounded, UL Listed, indoor fixtures except in heated air outlets or hazardous locations.

5.

The I-42-EM-A requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused A.C. lead.

6.

Do not mount near gas or electric heaters.

7.

The I-42-EM-A should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

8.

The I-42-EM-A will cold strike and operate one 10W through 42W, or two 10W through 26W, 4 pin Rapid

Start compact fluorescent lamps. Contact customer service for additional lamp usage.

9.

The I-42-EM-A is compatible with most electronic A.C. ballasts (including multiple lamps) as follows:

Electronic ballasts – one or two lamp emergency operation.

10.

The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

11.

Do not use this equipment for other than intended use.

12.

Install in accordance with the National Electrical Code and local regulations.

13.

Installation and servicing should be performed by qualified personnel.

14.

Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before final installation.

SAVE THESE INSTRUCTIONS

C

R

U

L

US LISTED

INSTALLATION INSTRUCTIONS

CAUTION: Before installing, make certain the A.C. power is off and the

I-42-EM-A unit connector is disconnected.

1. LAMPS OPERATED

Refer to the chart below for the type of lamp(s) operated and the number of lamps to be operated in the emergency mode.

If you have any questions regarding specific lamps, contact customer service.

O P T

1

2

3

4

I O N

1

1

1

0

8

L

4

A

W

2

0 W

W

-

-

M

3

W

1

2

P

2

6

W

3 W

W

C

C

T o o

Y m m

P p p

E a a c c t t

E M E R G E N C Y

O P E R A T I O N

O n e L a m p

O

T

T n w w e o o

L

L

L a a a m m m p p p

D

D i i

C s

V

L o

C o

I O

E n n s c o c o

L

A n n

E

D e c n n e c t t

T

S n n e c e c e t d e d e d t e d

W I R I N G

D I A G

1

1

R A M S

3

3

, 2

, 2

The 6

violet leads provide the lamp selection option. The unit is shipped from the factory with the leads disconnected and capped.

2. MOUNTING THE I-42-EM-A

When used with ceiling mounted downlight fixtures, the I-42-EM-A should be mounted on the fixture above the ceiling. The flex conduit marked “A” should be wired into the ballast/lamp compartment or to an electrical junction box on the fixture which allows access to the ballast/lamp connections. Refer to Illustration 1 for typical mounting.

When battery packs are remote mounted, the remote distance can not exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. For example, if the A.C. ballast manufacturer recommends no more than 25

remote distance, then the battery pack should not exceed 12½

. Under no circumstances should the battery pack exceed a distance of 50

from the lamp.

Illustration 1

Downlight Fixture

I-42-EM-A

FLEX “A”

A.C. BALLAST &

LAMP SOCKET COMPARTMENT

FLEX “B”

JUNCTION

BOX

SWITCH BOX

CEILING

TILE

TEST SWITCH

CHARGE LIGHT

INSURE WIRING IS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL REGULATIONS.

Page 2

3. MOUNTING THE TEST SWITCH AND CHARGE INDICATOR LIGHT

Cut the single gang switch box into the ceiling tile adjacent to the fixture within reach of the I-42-EM-A flex marked “B”. After mounting the switch box, connect flex “B” to the box and route all leads inside the box. Refer to Illustration 1 for typical mounting.

4. WIRING

A. The I-42-EM-A and A.C. ballast must be on the same branch circuit.

B. The I-42-EM-A requires an unswitched A.C. power source of either 120 or 277 volts; therefore, when used with switched fixtures, the I-42-EM-A input must be wired ahead of the switch.

C. Refer to the wiring diagrams on the back page for the proper wiring. For wiring diagrams of ballasts not shown, consult our customer service.

5. LABELS

Attach the appropriate labels adjacent to the Test Switch and Charge Indicator. Annotate Re-lamping label for lamp type and wattage. The Caution and the Re-lamping labels must be on the fixture in a readily visible location to anyone attempting to service the fixture.

6. COMPLETING INSTALLATION

When the installation is complete, switch the A.C. power on and join the I-42-EM-A unit connector.

OPERATION

General – This unit is primarily designed to be used with compact fluorescent lamp downlight fixtures. It will wire in conjunction with the existing A.C. ballast(s) and lamp(s) to provide the emergency function. It can also be wired for emergency only operation. The Test Switch and Charge Indicator light are offered in a standard single gang switch box for installation adjacent to the fixture.

Normal Mode – A.C. power is present. The A.C. ballast operates the fluorescent lamp(s) as intended. The I-42-EM-A is in the standby charging mode. The Charge Indicator will be lit providing a visual indication that the battery is being charged.

Emergency Mode – The A.C. power fails. The I-42-EM-A senses the A.C. power failure and automatically switches to the Emergency Mode. One lamp or two lamps are illuminated, at reduced output, for a minimum of 90 minutes. When the

A.C. power is restored, the I-42-EM-A switches the system back to the Normal Mode and resumes battery charging.

See page 1 of the Instruction Manual.

TESTING & MAINTENANCE

Pressing the Test Switch turns off the light on the Charge Indicator and forces the unit into emergency mode, interrupting power to the designated A.C. ballast. The emergency lamp is now being lit by the I-42-EM-A unit. After releasing the

Test Switch, the fixture returns to normal operation after a momentary delay. To simulate a “BLACK OUT” use the wall switch or circuit breaker to turn off A.C. power.

Initial Testing – Allow the unit to charge approximately 1 hour, then conduct a short discharge test by depressing the test switch. The Charge Indicator light will go out and the fluorescent tube will be illuminated. When the I-42-EM-A is used in fixtures with more than one A.C. ballast, the second A.C. ballast is NOT de-energized with the test switch. It may, therefore, be advisable to switch the A.C. fixture power off prior to depressing the test switch. Allow a 24 hour charge before conducting a one hour test.

The I-42-EM-A is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety

Code, outlines the following schedule:

Monthly – Insure that the Charge Indicator light is illuminated. Conduct a 30 second discharge test by depressing the

Test Switch. One lamp should operate at reduced output.

Annually – Insure that the Charge Indicator light is illuminated. Conduct a full 1½ hour discharge test. The unit should operate as intended for the duration of the test.

“Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.”

SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.

Consult Customer Service or visit www.iotaengineering.com for current warranty information.

Page 3

TYPICAL WIRING DIAGRAMS

Use in conjunction with Rapid Start ballasts and 4 pin lamps only.

1. ONE LAMP RAPID START BALLAST

UNSWITCHED

LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

WHITE

BLACK

ONE LAMP

A.C.

BALLAST

BLK (120V)

ORG (277V)

WHITE

WHT/BLK

TEST

SWITCH

BLUE

BLUE

RED

RED

*LAMP

*A.C./EMERGENCY LAMP

WHITE

WHT/BLK

FLEX A

BLUE

BLU/WHT

YELLOW

RED/WHT

RED

EMERGENCY

I-42-EM-A

BALLAST

FLEX B

VIOLET

VIOLET

RED OR RED/BLK (+)

WHT/RED

WHT/BLK

WHT/BLK

CHARGE

INDICATOR

UNIT CONNECTOR

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

LAMP SELECTOR LEADS. REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER APPLICATION.

DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND A.C. POWER IS SUPPLIED.

TEST ACCESSORY LEAD—REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POSITIVE LEAD WIRING.

2. TWO LAMP RAPID START BALLAST WITH ONE LAMP EMERGENCY OPERATION

UNSWITCHED

LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

WHITE

BLACK

TWO LAMP

A.C.

BALLAST

BLUE

BLUE

RED

RED

YEL

YEL

LAMP

BLK (120V)

ORG (277V)

WHITE

WHT/BLK

TEST

SWITCH

*LAMP

WHITE

WHT/BLK

FLEX A

BLUE

BLU/WHT

YELLOW

RED/WHT

RED

*A.C./EMERGENCY LAMP

EMERGENCY

I-42-EM-A

BALLAST

FLEX B

VIOLET

VIOLET

RED OR RED/BLK (+)

WHT/RED

WHT/BLK

WHT/BLK

CHARGE

INDICATOR

UNIT CONNECTOR

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

LAMP SELECTOR LEADS. REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER APPLICATION.

DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND A.C. POWER IS SUPPLIED.

TEST ACCESSORY LEAD—REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POSITIVE LEAD WIRING.

3. TWO LAMP RAPID START BALLAST WITH TWO LAMP EMERGENCY OPERATION

UNSWITCHED

LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

WHITE

BLACK

TWO LAMP

A.C.

BALLAST

BLUE

BLUE

RED

RED

YEL

YEL

*LAMP

BLK (120V)

ORG (277V)

WHITE

WHT/BLK

TEST

SWITCH

*LAMP

WHITE

WHT/BLK

FLEX A

BLUE

BLU/WHT

YELLOW

RED/WHT

RED

*A.C./EMERGENCY LAMP

EMERGENCY

I-42-EM-A

BALLAST

FLEX B

VIOLET

VIOLET

RED OR RED/BLK (+)

WHT/RED

WHT/BLK

WHT/BLK

CHARGE

INDICATOR

UNIT CONNECTOR

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

LAMP SELECTOR LEADS. REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER APPLICATION.

DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND A.C. POWER IS SUPPLIED.

TEST ACCESSORY LEAD—REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POSITIVE LEAD WIRING.

Rev. 112204

68442-102

Page 4