OMRON OMNUC U R88M-Ujjj30j-jj, R88M-Ujjj30T-jj AC Servomotor, OMNUC U R88D-UTjjj-j AC Servo Driver User’s Manual
Below you will find brief information for OMNUC U R88M-Ujjj30j-jj, OMNUC U R88M-Ujjj30T-jj, and OMNUC U R88D-UTjjj-j. The OMNUC U series is a fully digital AC servo driver built on advanced OMRON software servo technology. This manual describes the functions of the products, relations with other products and the installation and operation procedure. The document also describes how to make basic adjustments and troubleshooting. The manual includes a table of specifications, connection examples, and a combination of servo drivers and servomotors.
PDF
Download
Document
Advertisement
Advertisement
Thank you for choosing this OMNUC U-series product. Proper use and handling of the product will ensure proper product performance, will length product life, and may prevent possible accidents. Please read this manual thoroughly and handle and operate the product with care. NOTICE 1. This manual describes the functions of the product and relations with other products. You should assume that anything not described in this manual is not possible. 2. Although care has been given in documenting the product, please contact your OMRON representative if you have any suggestions on improving this manual. 3. The product contains dangerous high voltages inside. Turn off the power and wait for at least five minutes to allow power to discharge before handling or working with the product. Never attempt to disassemble the product. 4. We recommend that you add the following precautions to any instruction manuals you prepare for the system into which the product is being installed. S Precautions on the dangers of high-voltage equipment. S Precautions on touching the terminals of the product even after power has been turned off. (These terminals are live even with the power turned off.) 5. Specifications and functions may be changed without notice in order to improve product performance. 6. Positive and negative rotation of AC Servo Motors described in this manual are defined as looking at the end of the output shaft of the motor as follows: counterclockwise rotation is positive and clockwise rotation is negative. 7. Do not perform withstand-voltage or other megameter tests on the product. Doing so may damage internal components. 8. Servo Motors and Servo Drivers have a finite service life. Be sure to keep replacement products on hand and to consider the operating environment and other conditions affecting the service life. 9. The OMNUC UTj can control both incremental and absolute encoders. Differences in functions or specifications according to the encoder type are indicated in this manual. Be sure to check the model that is being used, and follow the relevant specifications. S Servo Motor with incremental encoder: R88M-Ujjj30H-j/V-jS1 S Servo Motor with absolute encoder: R88M-Ujjj30T-j/V-jS1 Items to Check After Unpacking Check the following items after removing the product from the package: S Has the correct product been delivered (i.e., the correct model number and specifications)? S Has the product been damaged in shipping? S Are any screws or bolts loose? USER’S MANUAL OMNUC U SERIES MODELS R88M-Uj (AC Servo Motors) MODELS R88D-UTj (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kW) No. 6182 OMRON Corporation Read and Understand this Manual Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 1 No. 6182 Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 2 No. 6182 Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 3 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. ! DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. OMRON, 1996 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. General Warnings Observe the following warnings when using the OMNUC Servomotor and Servo Driver including Parameter Unit, Regenerative Unit, and peripheral devices. This manual may include illustrations of the product with protective covers removed in order to describe the components of the product in detail. Make sure that these protective covers are on the product before use. Consult your OMRON representative when using the product after a long period of storage. ! WARNING Always connect the frame ground terminals of the Servo Driver and the Servomotor to a class-3 ground (to 100 Ω or less). Not connecting to a class-3 ground may result in electric shock. ! WARNING Do not touch the inside of the Servo Driver. Doing so may result in electric shock. ! WARNING Do not remove the front cover, terminal covers, cables, Parameter Units, or optional items while the power is being supplied. Doing so may result in electric shock. ! WARNING Installation, operation, maintenance, or inspection must be performed by authorized personnel. Not doing so may result in electric shock or injury. ! WARNING Wiring or inspection must be performed at least 5 minutes after turning off the power supply. Doing so may result in electric shock. ! WARNING Do not damage, press, or put excessive stress or heavy objects on the cables. Doing so may result in electric shock. ! WARNING Do not touch the rotating parts of the Servomotor under operation. Doing so may result in injury. ! WARNING Do not modify the product. Doing so may result in injury or damage to the product. ! Caution Use the Servomotors and Servo Drivers in a specified combination. Doing so may result in fire or damage to the products. ! Caution Do not store or install in the following places. Doing so may result in fire or damage to the Product. S Locations subject to direct sunlight. S Locations subject to temperatures or humidity outside the range specified in the specifications. S Locations subject to condensation as the result of severe changes in temperature. S Locations subject to corrosive or flammable gases. S Locations subject to dust (especially iron dust) or salts. S Locations subject to shock or vibration. S Locations subject to exposure to water, oil, or chemicals. ! Caution Do not touch the Servo Driver radiator or Servomotor while the power is being supplied or soon after the power is turned off. Doing so may result in a skin burn due to the hot surface. Storage and Transportation Precautions ! Caution Do not hold by the cables or motor shaft while transporting the product. Doing so may result in injury or malfunction. ! Caution Do not place any load exceeding the figure indicated on the product. Doing so may result in injury or malfunction. ! Caution Use the motor eye-bolts only for transporting the Motor. Using them for transporting the machinery may result in injury or malfunction. Installation and Wiring Precautions ! Caution Do not step on or place a heavy object on the product. Doing so may result in injury. ! Caution Do not cover the inlet or outlet ports and prevent any foreign objects from entering the product. Doing so may result in fire. ! Caution Be sure to install the product in the correct direction. Not doing so may result in malfunction. ! Caution Provide the specified clearances between the Servo Driver and the control panel or with other devices. Not doing so may result in fire or malfunction. ! Caution Do not apply any strong impact. Doing so may result in malfunction. ! Caution Be sure to wire correctly and securely. Not doing so may result in motor runaway, injury, or malfunction. ! Caution Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction. ! Caution Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connection of bare stranded wires may result in burning. ! Caution Always use the power supply voltage specified in the User’s Manual. An incorrect voltage may result in malfunction or burning. ! Caution Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied. Be particularly careful in places where the power supply is unstable. An incorrect power supply may result in malfunction. ! Caution Install external breakers and take other safety measures against short-circuiting in external wiring. Insufficient safety measures against short-circuiting may result in burning. ! Caution Provide an appropriate stopping device on the machine side to secure safety. (A holding brake is not a stopping device for securing safety.) Not doing so may result in injury. ! Caution Provide an external emergency stopping device that allows an instantaneous stop of operation and power interruption. Not doing so may result in injury. ! Caution Take appropriate and sufficient countermeasures when installing systems in the following locations: S Locations subject to static electricity or other forms of noise. S Locations subject to strong electromagnetic fields and magnetic fields. S Locations subject to possible exposure to radioactivity. S Locations close to power supplies. Operation and Adjustment Precautions ! Caution Check the newly set parameters for proper execution before actually running them. Not doing so may result in equipment damage. ! Caution Do not make any extreme adjustments or setting changes. Doing so may result in unstable operation and injury. ! Caution Separate the Servomotor from the machine, check for proper operation, and then connect to the machine. Not doing so may cause injury. ! Caution When an alarm occurs, remove the cause, reset the alarm after confirming safety, and then resume operation. Not doing so may result in injury. ! Caution Do not come close to the machine immediately after resetting momentary power interruption to avoid an unexpected restart. (Take appropriate measures to secure safety against an unexpected restart.) Doing so may result in injury. ! Caution Do not use the built-in brake of the Servomotor for ordinary braking. Doing so may result in malfunction. Maintenance and Inspection Precautions ! WARNING ! Caution Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock. Resume operation only after transferring to the new Unit the contents of the data required for operation. Not doing so may result in an unexpected operation. Warning Labels Warning labels are pasted on the product as shown in the following illustration. Be sure to follow the instructions given there. Warning labels Warning Labels for Non-conforming Models Warning label 2 Warning label 1 Warning Labels for Models Conforming to EC Directives Warning label 2 Warning label 1 VISUAL INDEX For users who wish to operate as quickly as possible. - The following portions of this manual provide the minimum information required for operation. Be sure you fully understand at least the information in these portions before attempting operation. Chapter 2 System Design and Installation, and sections 3-1, 3-2, 3-3, and 3-4 of Chapter 3 Operation. Instructions for jog operation using a Parameter Unit are provided in 3-4. SYSMAC C/CV Programmable Controller Position Control Unit C500-NC222-E Motion Control Units CV500-MC221/421 C200H-MC221 Analog input Pulse train input Position Control Units 3G2A5-NC111-EV1 C500-NC211 SYSMAC C/CV Programmable Controller SYSMAC C200HX/HG/HE Programmable Controller Controller Connecting Cable Chapter 5: 5-3-1 Position Control Units C200H-NC112 C200H-NC211 C200HW-NC113 C200HW-NC213 C200HW-NC413 Setting Functions - Using Parameter Unit: - Setting, checking setup parameters: - Important setup parameters: - Setting, checking user parameters - Important user parameters OMNUC U is a series of fully digital AC servo drivers built on advanced OMRON software servo technology. It provides high performance, a sensitive man-machine interface, and economy. Chapter 3, section 3-1-3 Chapter 3, section 3-3-1 Chapter 3, section 3-3-1 Chapter 3, section 3-3-2 Chapter 3, section 3-3-3 Adjustments and Troubleshooting - Making adjustments: Chapter 3, section 3-5 - Using displays: Chapter 4, section 4-2 - Using monitor outputs: Chapter 4, section 4-3 - Protections and diagnostic functions:Chapter 4, section 4-4 OMNUC U Series Parameter Units Operation Method Chapter 3: 3-1, 3-2, 3-3 OMNUC U-series AC Servo Driver I/O Operations Chapter 5: 5-1-3 Cable Specifications Chapter 5: 5-3-2, 5-3-3 Motor Specifications Chapter 5: 5-2 OMNUC U-series AC Servomotor (with incremental encoder) OMNUC U-series AC Servomotor (with absolute encoder) Table of Contents Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-2 1-3 1-4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Servo Driver Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Applicable Standards and Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 2. System Design and Installation . . . . . . . . . . . . . . . . . . . . . . 2-1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-1 External Dimensions (Unit: mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-2 Installation Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Wiring and Connections (Models Not Conforming to Standards) . . . . . . . . . . . . . . . . . . . . . . 2-2-1 Connecting OMRON Servo Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-2 Wiring Servo Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-3 Wiring for Noise Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-4 Peripheral Device Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Wiring and Connections (Models Conforming to EC Directives) . . . . . . . . . . . . . . . . . . . . . . 2-3-1 Connecting OMRON Servo Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-2 Wiring Servo Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-3 Wiring Conditions Satisfying EMC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-4 Peripheral Device Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 3. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Beginning Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1-1 Operational Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1-2 Turning On Power and Checking Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1-3 Using Parameter Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 System Check Mode (Cn-00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Function Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-1 Setting and Checking Setup Parameters (Cn-01, 02) . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-2 Setting and Checking User Parameters (Cn-03 to 2d) . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-3 Important User Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-4 Setting Internal Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-5 Switching Control Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-6 Software Start Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-7 Electronic Gear Function (Position Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-8 Encoder Dividing Function [Incremental] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-9 Encoder Dividing Function (Absolute) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-10 Bias Function (Position Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-11 Torque Limit Function (Position Control, Speed Control, Torque Control) . . . . . . . . 3-3-12 Speed Limit Function (Torque Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-13 Torque Feed-forward Function (Speed Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-14 Brake Interlock (for Motors With Brakes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Making Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5-1 Auto-tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5-2 Manually Adjusting Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5-3 Adjusting Command Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Regenerative Energy Absorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6-1 Calculating Regenerative Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6-2 Servo Driver Absorbable Regenerative Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table of Contents 3-6-3 Absorption of Regenerative Energy with External Regenerative Resistors Connected to Models Complying with EC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 4. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Absolute Encoder Setup and Battery Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-1 Absolute Encoder Setup [Absolute] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-2 Replacing Batteries [Absolute] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Using Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-1 Display Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-2 Status Display Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-3 Monitor Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-4 Checking Servomotor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Using Monitor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Protective and Diagnostic Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4-1 Alarm Displays and Alarm Code Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4-2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 5. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Servo Driver Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-1 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-2 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-3 I/O Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-4 Explanation of User Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Servomotor Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2-1 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2-2 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2-3 Torque and Rotation Speed Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2-4 Allowable Loads on Servomotor Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2-5 Encoder Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3-1 Controller Connecting Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3-2 Encoder Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3-3 Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 Parameter Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 6. Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-2 6-3 6-4 Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encoder Divider Rate for Servo Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OMNUC U-series Standard Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Combinations of Servo Drivers and Servomotors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Chapter 1 Introduction 1-1 1-2 1-3 1-4 Features System Configuration Servo Driver Nomenclature Applicable Standards and Models Chapter 1 Introduction 1-1 Features With their superior performance and fast response times, and an output capacity of up to 5 kW, these AC Servomotors and Servo Drivers have improved features of previous models. H Models Bearing the CE Marking and Complying with EC Directives Servo Driver and Servomotor models satisfying the LVD (Low-voltage Directive) and EMC (electromagnetic compatibility) requirements of EC Directives are available. These models are the same as the U-series models in performance and function and help a customer’s products equipped with these models satisfy EC Directives with ease. H Motor Output A line of models with the following outputs is available. H Servo Drivers Requiring External Regenerative Resistors Servomotor models connecting to external regenerative resistors and complying with EC Directives are available. These Servomotor models are available for vertical shaft applications and other applications that generate high regenerative energy. For application details, refer to 3-6 Regenerative Energy Absorption. H Model Number Legend D Servo Drivers R88D-UTjjj-j 1 2 3 Legend number Item 1 Maximum output current 2 Applicable standard 3 Regenerative resistor specifications Symbol (example) 24 40 H V No indication RG Description Approx. 24 A Approx. 40 A Models not conforming to standards Models conforming to EC Directives --Models requiring external regenerative resistors (see note 1) Note Although the R88D-UT110V has no indication for the regenerative resistor specifications, the model requires an external regenerative resistor. 1-2 Chapter 1 Introduction D Servomotors R88M-Ujjj30j-jj 1 2 3 4 3 and 4: Option Specifications Legend number Item 1 Motor capacity y 2 Applicable sta da d/e code ty e standard/encoder type Symbol (example) 1K0 1K5 H T V X 3 Brake specifications 4 Shaft shape No indication B No indication S1 Description 1.0 kW 1.5 kW Models not conforming to standards Incremental encoder Models not conforming to standards Absolute encoder Models conforming to EC Directives Incremental encoder Models conforming to EC Directives Absolute encoder Without brake With brake Straight shaft without key Straight shaft with key (see note 1) Note 1. Models conforming to EC Directives are available only for straight shafts with keys. Note 2. For details about model numbers, refer to 6-3 OMNUC U-series Models. For details about combinations of Servo Drivers and Servomotors, refer to 6-4 Combinations of Servo Drivers and Servomotors. H Control Functions Any one of the following 12 control modes can be selected in the parameter settings, thereby allowing various applications with a single Servo Driver. Control mode Speed control (Analog command) Position control (Pulse train command) Torque control (Analog command) [factory setting] Internal speed control settings Internal speed control settings ←→ Internal speed control settings ←→ Internal speed control settings ←→ Position control (Pulse train command) ←→ Position control (Pulse train command) ←→ Speed control (Analog command) ←→ Speed control (Analog command) ←→ Position control (Pulse train command) ←→ [Factory setting] Speed control (Analog command) Position control (Pulse train command) Torque control (Analog command) Speed control (Analog command) Torque control (Analog command) Torque control (Analog command) Position-lock stop Pulse prohibit 1-3 Chapter 1 Introduction H Auto-tuning The gain can be adjusted automatically when the responsiveness has been selected to match the rigidity of the mechanical system. The auto-tuning feature automatically finds the optimum adjustment to match the load, with no need for difficult operations. H Monitor Displays the driver’s operating status on the Parameter Unit. The following items can be monitored: speed feedback, speed commands, torque commands, number of pulses from the U-phase edge, electrical angle, the internal status (bit display), command pulse speed, position deviation, and input pulse counter. H Jog Operation Forward/Reverse motor operation can be controlled from the Parameter Unit. Rotational speed can be set in the parameters. H Automatic Adjustment of Control Offset (Speed Control and Torque Control) The offsets of the speed command input and torque command input can be adjusted automatically. H Electronic Gear Function (Position Control) This function turns the motor by the number of pulses obtained by applying the gear ratio to the number of command pulses. It can be effectively used in the following situations. S When fine tuning positions and speeds while synchronizing two lines. S When using a controller with a short command pulse frequency. S When setting the mechanical movement per pulse to amounts such as 0.01 mm. The electronic gear ratio is set by parameters (numerator: G1; denominator: G2). The setting range for G1 and G2 is 1 to 65,535, with 0.01 x (G1/G2) x 100. H Encoder Resolution Function This function allows the encoder signal output from the driver to be set anywhere within the ranges shown below for incremental and absolute. S [Incremental]: 16 to 4,096 pulses/revolution S [Absolute]: 16 to 8,192 pulses/revolution H Software Start Function (Speed Control, Internal Speed Control Settings) This function causes the motor to be started/stopped in the preset acceleration/deceleration times, allowing a simple position control system to be constructed without a Positioner or Host Controller. The acceleration and deceleration times are set separately, and the setting range is 0 to 10 s for each. 1-4 Introduction Chapter 1 H Pulse Smoothing Function (Position Control) Applying acceleration and deceleration to command pulses enables tracking of high-frequency commands. The setting is the same for acceleration and deceleration times, and the range is 0 to 64 ms. H Reverse Mode Forward/Reverse commands can be switched in the parameters, without changing the wiring to the motor or encoder. H Brake Interlock Output Outputs a timing signal interlocked with the motor’s ON/OFF status and rotational speed. The holding brake of a motor with a brake can be operated reliably. H Output Signal Selection Function Any three output signals can be selected for output from among the following seven: Positioning completed, motor rotation detection, servo preparation completed, electrical current limit detection, brake interlock, overload warning, and overload alarm. H Overtravel Sequence An overtravel sequence compatible with the system can be selected. There are three deceleration methods available: dynamic brake deceleration, free-run deceleration, and emergency-stop torque deceleration (parameter setting). H Feed-forward Function, Bias Function (Position Control) These functions reduce the position control time. S Feed-forward Function Reduces the position control time by reducing the number of pulses accumulated in the deviation counter. S Bias Function Reduces the position control time by adding the bias revolutions to the speed control when the deviation counter value exceeds the position completion range. H Personal Computer Monitor The special Servodriver Communications Software allows parameter setting, speed and current monitoring, I/O monitoring, auto-tuning, and jog operations to be performed from a personal computer. It is also possible to perform multiple-axis communications that set the parameters and monitor operation of several drivers. 1-5 Chapter 1 Introduction 1-2 System Configuration Controller (Voltage Output Models) + SYSMAC C/CV Programmable Controller Motion Control Unit CV500-MC221/421 C200H-MC221 Position Control Unit C500-NC222-E Parameter Units Controller (Pulse Train Output Models) OMNUC U-series AC Servo Driver + SYSMAC C/CV Programmable Controller Position Control Units C500-NC111-EV1 C500-NC211 C200H-NC112 C200H-NC211 C200H-NC113 C200H-NC213 C200H-NC413 [Incremental] [Absolute] OMNUC U-series AC Servomotor Note Motors with absolute encoders can be used in combination with CV500-MC221/421 or C200HMC221 Motion Control Units. 1-6 Chapter 1 Introduction 1-3 Servo Driver Nomenclature H Front View CN3: Parameter Unit connector Power supply indicator CN4: Connector for monitor output Alarm indicator SW1: Unit No. setting switch (when personal computer monitor is used) CN1: Control I/O connector CN2: Encoder connector Charge indicator Terminal block 1-7 Chapter 1 Introduction 1-4 Applicable Standards and Models H Applicable Standards EC Directives Low voltage EMC Product AC Servo Driver Applicable standard EN61010-1 AC Servo Motor IEC34-1, -5, -8, -9 AC Servo Driver EN55011 class A and AC Servomotor group 1 EN50082-2 Remarks Safety requirements for electrical equipment for measurement, control, and laboratory use. Rotating electrical machines. Limits and methods of measurement of radio disturbance characteristics of industrial, scientific, and medical (ISM) radio-frequency equipment. Electromagnetic compatibility generic immunity standard, Part 2 Industrial environment. Note Installation under the conditions specified in 2-3-3Wiring Conditions Satisfying EMC Directives is required to conform to EMC Directives. H Applicable Models Supply pp y voltage g 200 VAC Output p 1 kW 1.5 kW 2 kW 3 kW 4 kW 5 kW 1-8 AC Servo Driver R88D-UT24V R88D-UT24V-RG R88D-UT40V R88D-UT40V-RG R88D-UT60V R88D-UT60V-RG R88D-UT80V R88D-UT80V-RG R88D-UT110V R88D-UT110V AC Servomotor Incremental Encoder Absolute Encoder R88M-U1K030V-jS1 R88M-U1K030X-jS1 R88M-U1K530V-jS1 R88M-U1K530X-jS1 R88M-U2K030V-jS1 R88M-U2K030X-jS1 R88M-U3K030V-jS1 R88M-U3K030X-jS1 R88M-U4K030V-jS1 R88M-U4K030X-jS1 R88M-U5K030V-jS1 R88M-U5K030X-jS1 2 Chapter 2 System Design and Installation 2-1 2-2 2-3 Installation Wiring and Connections (Models Not Conforming to Standards) Wiring and Connections (Models Conforming to EC Directives) System Design and Installation Chapter 2 Installation and Wiring Precautions ! Caution Do not step on or place a heavy object on the product. Doing so may result in injury. ! Caution Do not cover the inlet or outlet ports and prevent any foreign objects from entering the product. Doing so may result in fire. ! Caution Be sure to install the product in the correct direction. Not doing so may result in malfunction. ! Caution Provide the specified clearances between the Servo Driver and the control panel or with other devices. Not doing so may result in fire or malfunction. ! Caution Do not apply any strong impact. Doing so may result in malfunction. ! Caution Be sure to wire correctly and securely. Not doing so may result in motor runaway, injury, or malfunction. ! Caution Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction. ! Caution Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connection of bare stranded wires may result in burning. ! Caution Always use the power supply voltage specified in the User’s Manual. An incorrect voltage may result in malfunction or burning. ! Caution Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied. Be particularly careful in places where the power supply is unstable. An incorrect power supply may result in malfunction. ! Caution Install external breakers and take other safety measures against short-circuiting in external wiring. Insufficient safety measures against short-circuiting may result in burning. ! Caution Provide an appropriate stopping device on the machine side to secure safety. (A holding brake is not a stopping device for securing safety.) Not doing so may result in injury. ! Caution Provide an external emergency stopping device that allows an instantaneous stop of operation and power interruption. Not doing so may result in injury. 2-2 Chapter 2 System Design and Installation ! Caution Take appropriate and sufficient countermeasures when installing systems in the following locations: S Locations subject to static electricity or other forms of noise. S Locations subject to strong electromagnetic fields and magnetic fields. S Locations subject to possible exposure to radioactivity. S Locations close to power supplies. 2-1 Installation 2-1-1 External Dimensions (Unit: mm) H AC Servo Drivers D 1.0-kW/1.5-kW Models: R88D-UT24H/-UT40H, R88D-UT24V/-UT40V, R88D-UT24V-RG/-UT40V-RG 110 92 60.5 250 235 189.5 Two, 5.5 dia. 5.5 35 125 65 2-3 Chapter 2 System Design and Installation D 2.0-kW/3.0-kW Models: R88D-UT60H/-UT80H, R88D-UT60V/-UT80V, R88D-UT60V-RG/-UT80V-RG 135 117 60.5 250 235 189.5 Two, 5.5 dia. 5.5 35 125 65 D 4.0-kW/5.0-kW Models: R88D-UT110H/-UT120H 210 194 22 250 Two, 6 dia. 235 150 6 2-4 35 121 69 System Design and Installation Chapter 2 D 4.0-kW/5.0-kW Models: R88D-UT110V Two, 7 dia. 2-5 Chapter 2 System Design and Installation H Parameter Units D R88A-PR02U Two, 4.5-mm dia. holes 18.5 63 50 7 125 135 (8) 1000 D R88A-PR03U 54 57.5 2-6 15 6.9 Chapter 2 System Design and Installation H AC Servomotors (Incremental) D 1.0-kW/1.5-kW/2.0-kW Standard Models: R88M-U1K030H/-U1K530H/-U2K030H R88M-U1K030V-S1/-U1K530V-S1/-U2K030V-S1 L LL 45 46 95h7 dia. 130 dia. 100 24h6 dia. 100 115 dia. 96 87 40 10 Four, 7 dia. 3 Note The model number with the suffix “S1” indicates a straight-shaft motor with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. D 1.0-kW/1.5-kW/2.0-kW Models with Brake: R88M-U1K030H-B/-U1K530H-B/-U2K030H-B R88M-U1K030V-BS1/-U1K530V-BS1/-U2K030V-BS1 L LL 45 46 100 95h7 dia. 24h6 dia. 100 130 dia. 115 dia. 100 87 40 10 3 Four, 7 dia. Note The model number with the suffix “S1” indicates a straight-shaft motor with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. Standard Models Model L R88M-U1K030j 194 R88M-U1K530j 220 R88M-U2K030j 243 LL 149 175 198 Models with Brake Model L R88M-U1K030j-Bj 238 R88M-U1K530j-Bj 264 R88M-U2K030j-Bj 287 LL 193 219 242 2-7 Chapter 2 System Design and Installation D 3.0-kW/4.0-kW/5.0-kW Standard Models: R88M-U3K030H/-U4K030H/-U5K030H R88M-U3K030V-S1/-U4K030V-S1/-U5K030V-S1 L LL 63 130 110h7 dia. 130 28h6 dia. 46 165 dia. 145 dia. 114 87 55 12 Four, 9 dia. 6 Note The model number with the suffix “S1” indicates a straight-shaft motor with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. D 3.0-kW/4.0-kW/5.0-kW Models with Brake: R88M-U3K030H-B/-U4K030H-B/-U5K030H-B R88M-U3K030V-BS1/-U4K030V-BS1/-U5K030V-BS1 L LL 63 46 110h7 dia. 130 28h6 dia. 130 165 dia. 145 dia. 119 87 55 12 6 Four, 9 dia. Note The model number with the suffix “S1” indicates a straight-shaft motor with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. Standard Models Models with Brake Model L LL Model L LL R88M-U3K030j 262 199 R88M-U3K030j-Bj 300 237 R88M-U4K030j 299 236 R88M-U4K030j-Bj 337 274 R88M-U5K030j 339 276 R88M-U5K030j-Bj 377 314 2-8 Chapter 2 System Design and Installation H AC Servomotors (Absolute) D 1.0-kW/1.5-kW/2.0-kW Standard Models: R88M-U1K030T/-U1K530T/-U2K030T R88M-U1K030X-S1/-U1K530X-S1/-U2K030X-S1 L LL 45 60 100 95h7 dia. 24h6 dia. 100 130 dia. 115 dia. 96 87 40 10 Four, 7 dia. 3 Note The model number with the suffix “S1” indicates a straight-shaft motor with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. D 1.0-kW/1.5-kW/2.0-kW Models with Brake: R88M-U1K030T-B/-U1K530T-B/-U2K030T-B R88M-U1K030X-BS1/-U1K530X-BS1/-U2K030X-BS1 L LL 45 60 130 dia. 100 95h7 dia. 24h6 dia. 100 115 dia. 100 87 40 10 3 Four, 7 dia. Note The model number with the suffix “S1” indicates a straight-shaft motor with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. Standard Models Model L R88M-U1K030j 208 R88M-U1K530j 234 R88M-U2K030j 257 LL 163 189 212 Models with Brake Model L R88M-U1K030j-Bj 252 R88M-U1K530j-Bj 278 R88M-U2K030j-Bj 301 LL 207 233 256 2-9 Chapter 2 System Design and Installation D 3.0-kW/4.0-kW/5.0-kW Standard Models: R88M-U3K030T/-U4K030T/-U5K030T R88M-U3K030X-S1/-U4K030X-S1/-U5K030X-S1 L LL 63 130 110h7 dia. 130 28h6 dia. 60 165 dia. 145 dia. 114 87 55 12 Four, 9 dia. 6 Note The model number with the suffix “S1” indicates a straight-shaft motors with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. D 3.0-kW/4.0-kW/5.0-kW Models with Brake: R88M-U3K030T-B/-U4K030T-B/-U5K030T-B R88M-U3K030X-BS1/-U4K030X-BS1/-U5K030X-BS1 L LL 63 130 110h7 dia. 130 28h6 dia. 60 165 dia. 145 dia. 119 87 55 12 6 Four, 9 dia. Note The model number with the suffix “S1” indicates a straight-shaft motors with key. For dimensions of the key sections, refer to Shaft Dimensions of Motors with Keys on page 2-11. Standard Models Model L R88M-U3K030j 276 R88M-U4K030j 313 R88M-U5K030j 353 2-10 LL 213 250 290 Models with Brake Model L R88M-U3K030j-Bj 314 R88M-U4K030j-Bj 351 R88M-U5K030j-Bj 391 LL 251 288 328 Chapter 2 System Design and Installation H Shaft Dimensions of Motors With Keys Standard U-series AC Servomotors do not have keys on the shafts. The dimensions of motors with keys are shown below. Motors with keys are indicated by adding “-S1” to the end of the model number. Key slots are based on JIS B1301-1976. D 1.0-kW/1.5-kW/2.0-kW Models Without Brake: R88M-U1K030j-S1 R88M-U1K530j-S1 R88M-U2K030j-S1 With Brake: R88M-U1K030j-BS1 R88M-U1K530j-BS1 R88M-U2K030j-BS1 32 4 24h6 dia 8 M8 effective depth 16 7 D 3.0-kW/4.0-kW/5.0-kW Models Without Brake: R88M-U3K030j-S1 R88M-U4K030j-S1 R88M-U5K030j-S1 With Brake: R88M-U3K030j-BS1 R88M-U4K030j-BS1 R88M-U5K030j-BS1 50 4 28h6 dia 8 7 M8 effective depth 16 2-11 Chapter 2 System Design and Installation 2-1-2 Installation Conditions H AC Servo Drivers D Space Around Drivers • Install Servo Drivers according to the dimensions shown in the following illustration to ensure proper heat dispersion and convection inside the panel. Also install a fan for circulation if Servo Drivers are installed side by side to prevent uneven temperatures from developing inside the panel. • Mount the Servo Drivers vertically (so that the model number and writing can be read). ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ Servo Driver Servo Driver W 30 mm min. 50 mm min. Fan Servo Driver Fan Side of Unit W W = 10 mm min. 50 mm min. D Operating Environment Be sure that the environment in which Servo Drivers are operated meets the following conditions. • Ambient operating temperature: 0°C to +55°C • Ambient operating humidity: 20% to 85% (RH, with no condensation) • Atmosphere: No corrosive gases. D Ambient Temperature • Servo Drivers should be operated in environments in which there is minimal temperature rise to maintain a high level of reliability. • Temperature rise in any Unit installed in a closed space, such as a control box, will cause the ambient temperature to rise inside the entire closed space. Use a fan or a air conditioner to prevent the ambient temperature of the Servo Driver from exceeding 55°C. • Unit surface temperatures may rise to as much as 30°C above the ambient temperature. Use heatresistant materials for wiring, and keep separate any devices or wiring that are sensitive to heat. • The service life of a Servo Driver is largely determined by the temperature around the internal electrolytic capacitors. The service life of an electrolytic capacitor is affected by a drop in electrolytic volume and an increase in internal resistance, which can result in overvoltage alarms, malfunctioning due to noise, and damage to individual elements. If a Servo Driver is always operated at the maximum ambient temperature of 40°C and at 80% of the rated torque, then a service life of approximately 50,000 hours can be expected. A drop of 10°C in the ambient temperature will double the expected service life. 2-12 Chapter 2 System Design and Installation D Keeping Foreign Objects Out of Units • Place a cover over the Units or take other preventative measures to prevent foreign objects, such as drill filings, from getting into the Units during installation. Be sure to remove the cover after installation is complete. If the cover is left on during operation, heat buildup may damage the Units. • Take measures during installation and operation to prevent foreign objects such as metal particles, oil, machining oil, dust, or water from getting inside of Servo Drivers. H AC Servomotors D Operating Environment Be sure that the environment in which the Servomotor is operated meets the following conditions. • Ambient operating temperature: 0°C to +40°C • Ambient operating humidity: 20% to 80% (RH, with no condensation) • Atmosphere: No corrosive gases. D Impact and Load • The Servomotor is resistant to impacts of up to 98 m/s2 (10 G). Do not subject it to heavy impacts or loads during transport, installation, or positioning. In addition, do not hold onto the encoder, cable, or connector areas when transporting it. • Always use a pulley remover to remove pulleys, couplings, or other objects from the shaft. • Secure cables so that there is no impact or load placed on the cable connector areas. D Connecting to Mechanical Systems • The axial loads for Servomotors are specified in section 5-2-4. If an axial load greater than that specified is applied to a Servomotor, it will reduce the service life of the motor bearings and may damage the motor shaft. When connecting to a load, use couplings that can sufficiently absorb mechanical eccentricity and variation. Motor shaft center line Ball screw center line Shaft core displacement Recommended Coupling Name Oldham coupling Maker Myghty Co., Ltd • For spur gears, an extremely large radial load may be applied depending on the gear precision. Use spur gears with a high degree of accuracy (for example, JIS class 2: normal line pitch error of 6 µm max. for a pitch circle diameter of 50 mm). If the gear precision is not adequate, allow backlash to ensure that no radial load is placed on the motor shaft. Backlash Adjust backlash by adjusting the distance between shafts. 2-13 Chapter 2 System Design and Installation • Bevel gears will cause a load to be applied in the thrust direction depending on the structural precision, the gear precision, and temperature changes. Provide appropriate backlash or take other measures to ensure that no thrust load is applied which exceeds specifications. Bevel gear • Do not put rubber packing on the flange surface. If the flange is mounted with rubber packing, the motor flange may separate due to the tightening strength. Make moveable. • When connecting to a V-belt or timing belt, consult the maker for belt selection and tension. A radial load twice the belt tension will be placed on the motor shaft. Do not allow a radial load exceeding specifications to be placed on the motor shaft due to belt tension. If an excessive radial load is applied, the motor shaft may be damaged. Set up the structure so that the radial load can be adjusted. A large radial load may also be applied as a result of belt vibration. Attach a brace and adjust Servo Driver gain so that belt vibration is minimized. Pulley for tension adjustment (Make adjustable.) Pulley Belt Tension Motor shaft Pulley D Water and Drip Resistance • The Servomotor is not of waterproof construction. The Servomotor is provided with either of the following protection. Models not complying with EC Directives: IP65 (excluding the shaft penetration areas) Models complying with EC Directives: IP55 (including the shaft penetration areas) The standard cable conforms to IP30. If the Power Cable or Encoder Cable is used in places wet with sprayed water, connect waterproof connectors to the Cable. If the equipment incorporating the Servomotor must comply with EC Directives, connect the following connectors to the Power Cable and Encoder Cable. 2-14 Chapter 2 System Design and Installation Recommended Connectors for Power Cables Motor model Without R88M-U1K030j-j brake R88M-U1K530j-j R88M-U2K030j-j Connector model Cable clamp model Maker Angled type For sheath external diam- DDK Ltd. CE05-8A18-10SD-B-BAS eter of 6.5 to 8.7 dia.: CE3057-10A-3 (D265) Straight type CE05-6A18-10SD-B-BSS For sheath external diameter of 8.5 to 11 dia.: CE3057-10A-2 (D265) R88M-U3K030j-j R88M-U4K030j-j R88M-U5K030j-j With brake R88M-U1K030j-Bj R88M-U1K530j-Bj R88M-U2K030j-Bj R88M-U3K030j-Bj R88M-U4K030j-Bj R88M-U5K030j-Bj Angled type JL04V-8A22-22SE-EB Straight type JL04V-6A22-22SE-EB Angled type JL04V-8A20-15SE-EB Straight type JL04V-6A20-15SE-EB Angled type JL04V-8A24-10SE-EB Straight type JL04V-6A24-10SE-EB For sheath external diameter of 10.5 to 14.1 dia.: CE3057-10A-1 (D265) For sheath external diam- Japan Aviation eter of 6.5 to 9.5 dia.: Electronics IndusJL04-2022CK(09) try, Ltd. (JAE) For sheath external diameter of 9.5 to 13 dia.: JL04-2022CK(12) For sheath external diameter of 12.9 to 15.9 dia.: JL04-2022CK(14) For sheath external diam- Japan Aviation eter of 6.5 to 9.5 dia.: Electronics IndusJL04-2022CK(09) try, Ltd. (JAE) For sheath external diameter of 9.5 to 13 dia.: JL04-2022CK(12) For sheath external diameter of 12.9 to 15.9 dia.: JL04-2022C K(14) For sheath external diam- Japan Aviation eter of 9 to 12 dia.: Electronics IndusJL04-2428CK(11) try, Ltd. (JAE) For sheath external diameter of 12 to 15 dia.: JL04-2428CK(14) For sheath external diameter of 15 to 18 dia.: JL04-2428CK(17) For sheath external diameter of 18 to 20 dia.: JL04-2428CK(20) 2-15 Chapter 2 System Design and Installation Recommended Connector for Encoder Cables Motor model All models Connector model Angled type JA08A-20-29S-J1-EB Straight type JA06A-20-29S-J1-EB Cable clamp model Maker For sheath external diame- Japan Aviation Electronics ter of 6.5 to 9.5 dia.: Industry, Ltd. (JAE) JL04-2022CKE(09) For sheath external diameter of 9.5 to 13 dia.: JL04-2022CKE(12) For sheath external diameter of 12.9 to 16 dia.: JL04-2022CKE(14) • If the Servomotor is used in an environment in which condensation occurs, water may enter inside of the encoder from the end surfaces of cables due to motor temperature changes. Either take measures to ensure that water cannot penetrate in this way, or use water-proof connectors. Even when machinery is not in use, water penetration can be avoided by taking measures, such as keeping the motor in servo-lock status, to minimize temperature changes. • If machining oil with surfactants (e.g., coolant fluids) or their spray penetrate inside of the motor, insulation defects or short-circuiting may occur. Take measures to prevent machining oil penetration. D Oil Seals If the motor shaft is exposed to oil or grease, attach an oil seal to the motor shaft. Oil seal model: SC30458 (NOK) D Other Precautions • Do not apply commercial power directly to the Servomotor. The Servomotors run on synchronous AC and use permanent magnets. Applying three-phase power will burn out the motor coils. • Take measures to prevent the shaft from rusting. The shafts are coated with anti-rust oil when shipped, but anti-rust oil or grease should also be applied when connecting the shaft to a load. • Absolutely do not remove the encoder cover or take the motor apart. The magnet and the encoder are aligned in the Servomotor. If they become misaligned, the motor will not operate. 2-16 Chapter 2 System Design and Installation 2-2 Wiring and Connections (Models Not Conforming to Standards) 2-2-1 Connecting OMRON Servo Controllers Use general-purpose control cable (purchased separately) to connect U-series AC Servomotors and Servo Drivers to OMRON Servo Controllers. H Connecting SYSMAC C-Series Position Control Units Programmable Controller SYSMAC C/CV Position Control Unit C500-NC222-E (Analog output) 3G2A5-NC111-EV1 (Pulse train output) C500-NC211 (Pulse train output) C200H-NC112 (Pulse train output) C200H-NC211 (Pulse train output) C200HW-NC113 (Pulse train output) C200HW-NC213 (Pulse train output) C200HW-NC413 (Pulse train output) General-purpose Control Cable R88A-CPUBjjjS AC Servo Driver R88D-UTjjH Encoder Cable R88A-CRUBjjjN Power Cable (1 kW to 2 kW) R88A-CAUBjjjS (for motor without brake) R88A-CAUBjjjB (for motor with brake) (3 kW to 5 kW) R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) AC Servo Motor R88M-Ujjj30H-j (with incremental encoder) 2-17 Chapter 2 System Design and Installation H Connecting to SYSMAC C/CV-series Motion Control Units Programmable Controller Motion Control Unit CV500-MC221 (Analog output) CV500-MC421-EV1 (Analog output) C200H-MC221 (Analog output) SYSMAC C/CV General-purpose Control Cable R88A-CPUBjjjM1 (for single axis) R88A-CPUBjjjM2 (for double axis) AC Servo Driver R88D-UTjjH Back-up Battery To be connected when using a motor with an absolute encoder Encoder Cable R88A-CRUBjjjN (for both incremental and absolute encoders) Power Cable (1 kW to 2 kW) R88A-CAUBjjjS (for motor without brake) R88A-CAUBjjjB (for motor with brake) (3 kW to 5 kW) R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) AC Servo Motor R88M-Ujjj30T-j (with absolute encoder) R88M-Ujjj30H-j (with incremental encoder) Note Refer to Chapter 5 Specifications for connector and cable specifications. 2-18 Chapter 2 System Design and Installation 2-2-2 Wiring Servo Drivers Provide proper wire diameters, ground systems, and noise resistance when wiring terminal blocks. H Wiring Terminal Blocks • R88D-UT24H/UT40H/UT60H/UT80H Control Circuit Power Supply Single-phase 200/230 VAC 50/60 Hz Power Cable Red White Black Green (1 kW to 2 kW) R88A-CAUBjjjS (for motor without brake) R88A-CAUBjjjB (for motor with brake) (3 kW to 5 kW) R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) Brown Signal line for brake R Class-3 ground min. 24 VDC ±10% No polarity Yellow S T P B Main Circuit Power Supply Three-phase 200/230 VAC 50/60 Hz 2-19 Chapter 2 System Design and Installation • R88D-UT110H/UT120H Main Circuit Power Control Circuit Power Supply Single-phase 200/230 VAC Supply 50/60 Hz Three-phase 200/230 VAC Red 50/60 Hz White Black Green Power Cable Class-3 ground min. R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) Brown Signal line for brake Terminal label Name Frame ground R S T r t P B N U V W 2-20 Main circuit power supply l input Control circuit power supply input Main circuit DC output ((positive) ii ) Yellow 24 VDC ±10% No polarity Function This is the ground terminal. Ground to a class-3 ground (to 100 Ω or less) or better. Three-phase 200/230 VAC ((170 to 253 V), ), 50/60 Hz Single-phase 200/230 VAC (170 to 253 V), 50/60 Hz Do not connect anything y g to these terminals. Main circuit DC output (negative) Motor connection Red These are the output terminals to the Servomotor. Be careful to wire terminals i l h correctly. l White them Black Frame ground Green Chapter 2 System Design and Installation H Terminal Block Current and Wire Sizes The following table shows the rated effective currents flowing to the Servo Driver and the sizes of the electrical wires. Driver (Watts) R88D-UT24H (1.0 kW) R88D-UT40H (1.5 kW) R88D-UT60H (2.0 kW) R88D-UT80H (3.0 kW) R88D-UT110 H (4.0 kW) R88D-UT120 H (5.0 kW) 9.2 A 13.0 A 18.4 A 24.0 A 28.0 A Main circuit power supply input (R, S, T) Effective current 6.6 A Wire size 3.5 mm2 or AWG 12 min. Control circuit power supply input (r, t) Effective current 0.25 A Motor connection i l (U, (U V, V terminal W) Effective current 6.1 A Wire size 3.5 mm2 or AWG 12 0.25 A 5.5 mm2 or AWG 10 min. 0.25 A 0.25 A 0.25 A 0.25 A 25.3 A 26.2 A 1.25 mm2 or AWG 16 min. Wire size 9.9 A 12.0 A 19.4 A 5.5 mm2 or AWG 10 min. Use OMRON standard cables. Frame ground Motor connector’s applicable cable size AWG 14 to AWG 12 Wire size Use 2.0-mm2 external ground wires. Use the same wire as used for the motor output. Terminal block screw size AWG 10 to AWG 8 M4 H Wire Sizes and Allowable Current The following table shows allowable currents when there are three electrical wires. Use values equal to or lower than the specified values. D 600-V Heat-resistant Vinyl Wiring (HIV) (Reference Values) AWG size Nominal crosssectional area 2) ( (mm Configuration ((wires/mm2) Conductive resistance (Ω/k ) (Ω/km) 16 14 12 10 8 6 1.25 2.0 3.5 5.5 8.0 14.0 7/0.45 7/0.6 7/0.8 7/1.0 7/1.2 7/1.6 17.5 9.53 5.41 3.47 2.41 1.35 Allowable current (A) for ambient temperature 30°C 16 23 33 43 55 79 40°C 14 20 29 38 49 70 50°C 11 16 24 31 40 57 2-21 Chapter 2 System Design and Installation 2-2-3 Wiring for Noise Resistance H Wiring Method Noise resistance will vary greatly depending on the wiring method used. Resistance to noise can be increased by paying attention to the items described below. AC power supply NFB Noise AC reactor filter Surge absorber 1 NF X1 4 2 5 3 6 E R88D-U Contactor t M V W T r Fuse R88M-U Metal duct TB U TB R S CN2 RE 2 mm2 min. 3.5mm2 Thick power line (3.5 mm2) Class-3 ground (to 100Ω or less) Ground plate Controller power supply Ground control panel Machine ground • Ground the motor’s frame to the machine ground when the motor is on a movable shaft. • Use a grounding plate for the frame ground for each Unit, as shown in the illustration, and ground to a single point. • Use ground lines with a minimum thickness of 3.5 mm2, and arrange the wiring so that the ground lines are as short as possible. • If no-fuse breakers are installed at the top and the power supply line is wired from the lower duct, use metal tubes for wiring and make sure that there is adequate distance between the input lines and the internal wiring. If input and output lines are wired together, noise resistance will decrease. • No-fuse breakers, surge absorbers, and noise filters (NF) should be positioned near the input terminal block (ground plate), and I/O lines should be isolated and wired using the shortest means possible. • Wire the noise filter as shown at the left in the following illustration. The noise filter should be installed at the entrance to the control panel whenever possible. Good: Separate input and output AC input Ground NF 1 4 2 3 5 6 E NO: Noise not filtered effectively NF AC output AC input Ground AC output 2-22 1 4 2 3 5 6 E Chapter 2 System Design and Installation • Use twisted-pair cables for the power supply cables whenever possible, or bind the cables. R r Driver S T or t Driver Binding • Separate power supply cables and signal cables when wiring. H Selecting Components D No-fuse Breakers (MCCB) When selecting no-fuse breakers, take into consideration the maximum output current and the inrush current. The momentary maximum output for a servo system is approximately three times that of the rated output, and a maximum output of three seconds can be executed. Therefore, select no-fuse breakers with an operating time of at least five seconds at 300% of the rated maximum output. Generalpurpose and low-speed no-fuse breakers are generally suitable. Refer to the table in 2-2-2 Terminal Block Wiring for the power supply input currents for each motor, and then add the current consumption for the number of shafts, other controllers, etc., to make the selection. The Servo Driver inrush current flows at a maximum of 50 A for 20 ms when 200 V is input. With lowspeed no-fuse breakers, a inrush current 7 to 8 times the rated current flows for 0.1 second. When making the selection, take into consideration the entire inrush current for the system. D Surge Absorbers Use surge absorbers to absorb surges from power supply input lines due to lightning, abnormal voltages, etc. When selecting surge absorbers, take into account the varistor voltage, the amount of surge immunity, and the amount of energy resistance. The surge absorbers shown in the following table are recommended. Maker Matsushita Electric P Parts Ishizuka Electronics Co. Model ERZC20EK471(W) ERZC25EK471(W) ERZC32EK471(W) Z25M471S Z33M471S Varistor voltage 470 V 470 V 470 V 470 V 470 V Max. limit voltage 775 V 775 V 775 V 810 V 810 V Surge immunity 5,000 A 10,000 A 20,000 A 10,000A 20,000 A Energy resistance 150 J 225 J 405 J 235 J 385 J Type Block Block Note 1. The (W) for the Matsushita models indicates that they are UL and CSA certified. Note 2. Refer to manufacturers documentation for operating details. Note 3. The surge immunity is for a standard impulse current of 8/20 µs. If pulses are wide, either decrease the current or change to a larger-capacity surge absorber. Note 4. The energy resistance is the value for 2 ms. It may not be possible to retard high-energy pulses at less than 700 V. In that case, absorb surges with an insulated transformer or reactor. 2-23 Chapter 2 System Design and Installation D Noise Filters for Power Supply Input Use a noise filter to attenuate extraneous noise and to diminish noise radiation from the Servo Driver. Select a noise filter with a load current of at least twice the rated current. The following table shows noise filters that reduce by 40 dB noise between 200 kHz and 30 MHz. Type Single-phase g Three-phase Model GT-2050 ZAC2206-11 LF-315K LF-325K LF-335K LF-380K ZCW2210-01 ZCW2220-01 ZCW2230-01 ZCW2240-01 ZACT2280-ME Rated current 5A 6A 15 A 25 A 35 A 80 A 10 A 20 A 30 A 40 A 80 A Maker Tokin TDK Tokin TDK To attenuate noise at frequencies of 200 kHz or less, use an insulated transformer and a noise filter. For high frequencies of 30 MHz or more, use a ferrite core and a high-frequency noise filter with a throughtype capacitor. D Noise Filters for Motor Output Use noise filters without built-in capacitors on the Servomotor output lines. Output lines cannot use the same noise filters as the power supply. The following table shows the noise filters that are recommended for motor output. Maker Tokin Model LF-310KA LF-320KA LF-350KA Rated current 10 A 20 A 50 A Remarks Three-phase block noise filter Note 1. The Servomotor output lines cannot use the same noise filters used for power supplies. Note 2. Typical noise filters are used with power supply frequencies of 50/60 Hz. If these noise filters are connected to outputs of 3.3 kHz (the Servo Driver’s PWM frequency), a very large (about 100 times larger) leakage current will flow through the noise filter’s condenser and the Servo Driver could be damaged. 2-24 Chapter 2 System Design and Installation D Surge Killers Install surge killers for loads that have induction coils, such as relays, solenoids, brakes, clutches, etc. The following table shows types of surge killers and recommended products. Type Diode Features Diodes are relatively small devices such as relays used for loads when reset time is not an issue. The reset time is increased because the surge voltage is the lowest when power is cut off. Used for 24/48-VDC systems. Thyristor or Varistor Thyristor and varistor are used for loads when induction coils are large, as in electromagnetic brakes, solenoids, etc., and when reset time is an issue. The surge voltage when power is cut off is approximately 1.5 times that of the varistor. Capacitor + resistor Use capacitors and resistors for vibration absorption of surge when power is cut off. The reset time can be shortened by proper selection of the capacitor or resistor. Recommended products Use a fast-recovery diode with a short reverse recovery time. Fuji Electric Co., ERB44-06 or equivalent Select varistor voltage as follows: 24-VDC system varistor: 100-VDC system varistor: 100-VAC system varistor: 200-VAC system varistor: Okaya Electric Ind. 39 V 200 V 270 V 470 V CR-50500 0.5 µF-50 Ω CRE-50500 0.5 µF-50 Ω S2-A-0 0.2 µF-500 Ω Note Thyristors and varistors are made by the following companies. Refer to manufacturers documentation for operating details. Thyristors: Ishizuka Electronics Co. Varistors: Ishizuka Electronics Co., Matsushita Electric Parts D Contactors When selecting contactors, take into consideration the circuit’s inrush current and the momentary maximum current. The Servo Driver inrush current is 50 A, and the momentary maximum current is approximately twice the rated current. The following table shows the recommended contactors. Maker OMRON Model LC1D25106 LC1D40116 LC1D50116 LC1D80116 LP1D25106 LP1D40116 LP1D50116 LP1D80116 Rated current 26 A 35 A 50 A 80 A 26 A 35 A 50 A 80 A Coil voltage 200 VAC 24 VDC D Leakage Breakers Select leakage breakers designed for inverters. Since switching takes place inside the Servo Drivers, high-frequency current leaks from the armature of the motor. With inverter leakage breakers, high-frequency current is not detected, preventing the breaker from operating due to leakage current. When selecting leakage breakers, remember to also add the leakage current from devices other than the Servomotor, such as machines using a switching power supply, noise filters, inverters, and so on. When selecting leakage breakers, refer to the manufacturer’s catalog. 2-25 Chapter 2 System Design and Installation The following table shows leakage current of each Servomotor. Driver Leakage current (direct measurement) (including high-frequency current) R88D-UT24H R88D-UT40H R88D-UT60H R88D-UT80H R88D-UT110H R88D-UT120H 50 mA Leakage current (resistor/capacitor measurement) (commercial power supply frequency range) 6 mA 70 mA 7 mA 90 mA 8 mA Note 1. The above leakage current is for cases where motor power line length is less than 10 m. (It varies depending on the power line length and insulation.) Note 2. The above leakage current is for normal temperature and humidity. (It varies depending on the temperature and humidity.) D AC Reactor The AC Reactor is used for suppressing harmonic currents. The AC Reactor suppresses sudden and quick changes in electric currents. In September 1994, the Ministry of International Trade and Industry established guidelines for the suppression of harmonic waves emitted from home and general electric appliances. In compliance with the guidelines, appropriate measures are required to suppress the influence of harmonic waves on power supply lines. Select a proper AC Reactor model according to the Servo Driver. Specifications of Applicable Models Servo Driver model d l R88D-UT24H R88D-UT40H R88D-UT60H R88D-UT80H R88D-UT110H R88D-UT120H 2-26 AC Reactor Model 3G3IV-PUZBAB10A1.1MH Rated current 10 A Inductance Loss Weight 1.1 mH 25 W 3 kg 3G3IV-PUZBAB15A0.71MH 3G3IV-PUZBAB20A0.53MH 3G3IV-PUZBAB30A0.35MH 15 A 20 A 30 A 0.71 mH 0.53 mH 0.35 mH 30 W 35 W 45 W 3 kg 3 kg 3 kg Chapter 2 System Design and Installation Dimensions 3G3IVPUZBABj 10A1.1MH 15A0.71MH 20A0.53MH 30A0.35MH Dimension (mm) Drawing number of external A dimensions 1 130 130 2 130 130 B 88 88 88 88 B1 C ----114 119 130 130 105 105 External Dimensions Drawing 1 D E 50 50 50 50 65 65 65 70 F 130 130 130 130 H J 22 22 22 22 M6 M6 M6 M6 K 11.5 11.5 11.5 9 L 7 7 7 7 M M4 M4 M4 M4 External Dimensions Drawing 2 M: Terminal M: Terminal Nameplate Nameplate 4-J: Mounting bolt 4-J: Mounting bolt Enlarged drawing of mounting hole Enlarged drawing of mounting hole H Improving Encoder Cable Noise Resistance Signals from the encoder are either A, B, or S phase (Z phase). The frequency for A- or B-phase signals is either 307.2 kHz (if an incremental encoder is used) or 614.4 kHz (if an absolute encoder is used), while the transmission speed for S-phase signals is 1.23 Mbps. Follow the wiring methods outlined below to improve encoder noise resistance. • Be sure to use dedicated encoder cables. • If lines are interrupted in the middle, be sure to connect them with connectors, making sure that the cable insulation is not peeled off for more than 50 mm. In addition, be sure to use shielded wire. • Do not coil cables. If cables are long and are coiled, mutual induction and inductance will increase and will cause malfunctions. Be sure to use cables fully extended. • When installing noise filters for encoder cables, use clamp cables. The following table shows the recommended clamp filter models. Maker Tokin TDK Name EMI core Clamp filter Model ESD-QR-25-1 ZCAT2032-0930 ZCAT3035-1330 ZCAT2035-0930A • Do not wire the encoder cable in the same duct as power cables and control cables for brakes, solenoids, clutches, and valves. 2-27 System Design and Installation Chapter 2 H Improving Control I/O Signal Noise Resistance Position can be affected if control I/O signals are influenced by noise. Follow the methods outlined below for the power supply and wiring. • Use completely separate power supplies for the control power supply (especially 24 VDC) and the external operation power supply. In particular, be careful not to connect two power supply ground wires. Install a noise filter on the primary side of the control power supply. • As much as possible, keep the power supply for pulse command and deviation counter reset input lines separate from the control power supply. Be particularly careful not to connect the two power supply ground lines. • It is recommended that a line driver be used for pulse command and deviation counter reset outputs. • Be sure to use twisted-pair shielded wire for pulse command and deviation counter reset signal lines, and connect both ends of the wires to frame grounds. • For speed and torque command input lines, be sure to use twisted-pair shielded cable, and connect both ends of the shield wire to ground. • If the control power supply wiring is long, noise resistance can be improved by adding 1-µF laminated ceramic capacitors between the control power supply and ground at the Servo Driver input section and the controller output section. • For encoder output (A, B, and Z phase) lines, be sure to use twisted-pair shielded cable, and connect both ends of the shield wire to ground. • For open collector specifications, keep the length of wires to within one meter. 2-28 Chapter 2 System Design and Installation 2-2-4 Peripheral Device Connection Examples R S T Three-phase, 200/230 VAC, 50/60 Hz NFB AC reactor 1 E 4 2 3 NF 5 6 Noise filter Main-circuit power supply OFF Main-circuit connector ON 1MC Class-3 ground 1MC X Surge killer OMNUC U-series AC Servo Driver Power Cable R88A-CAUBjjjS/-CAUCjjjS (-CAUBjjjB/-CAUCjjjB) r 1MC t OMNUC U-series AC Servomotor XB R S B 24VDC T U Class-3 ground V CN1 X M 31 ALM W 24 VDC 32 ALMCOM User’s control device X CN2 R88A-CRUBjjjC Encoder Cable E CN1 CN1 BKIR 27 XB 24 VDC OGND 28 (Note: Set by user parameter Cn-2d.) 2-29 Chapter 2 System Design and Installation 2-3 Wiring and Connections (Models Conforming to EC Directives) 2-3-1 Connecting OMRON Servo Controllers Use general-purpose control cable (purchased separately) to connect U-series AC Servomotors and Servo Drivers to OMRON Servo Controllers. H Connecting SYSMAC C-Series Position Control Units Programmable Controller Position Control Unit C500-NC211 (Pulse train output) C200HW-NC113 (Pulse train output) C200HW-NC213 (Pulse train output) C200HW-NC413 (Pulse train output) SYSMAC C/CV General-purpose Control Cable R88A-CPUBjjjS AC Servo Driver R88D-UTjjV-j Encoder Cable R88A-CRUBjjjN The cable is of IP30 construction. If more protection is required or to conform to the EC Directives, use the recommended connectors. Refer to 2-1-2 Installation Conditions. Power Cable (1 kW to 2 kW) R88A-CAUBjjjS (for motor without brake) R88A-CAUBjjjB (for motor with brake) (3 kW to 5 kW) R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) The cable is of IP30 construction. If more protection is required or to conform to the EC Directives, use the recommended connectors. Refer to 2-1-2 Installation Conditions. AC Servo Motor R88M-Ujjj30V-jS1 (with incremental encoder) 2-30 Chapter 2 System Design and Installation H Connecting to SYSMAC C/CV-series Motion Control Units Programmable Controller Motion Control Unit CV500-MC221 (Analog output) CV500-MC421-EV1 (Analog output) C200H-MC221 (Analog output) SYSMAC C/CV General-purpose Control Cable R88A-CPUBjjjM1 (for single axis) R88A-CPUBjjjM2 (for double axis) AC Servo Driver R88D-UTjjV-j Back-up Battery To be connected when using a motor with an absolute encoder Encoder Cable R88A-CRUBjjjN (for both incremental and absolute encoders) The cable is of IP30 construction. If more protection is required or to conform to the EC Directives, use the recommended connectors. Refer to 2-1-2 Installation Conditions. Power Cable (1 kW to 2 kW) R88A-CAUBjjjS (for motor without brake) R88A-CAUBjjjB (for motor with brake) (3 kW to 5 kW) R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) The cable is of IP30 construction. If more protection is required or to conform to the EC Directives, use the recommended connectors. Refer to 2-1-2 Installation Conditions. AC Servo Motor R88M-Ujjj30X-jS1 (with absolute encoder) R88M-Ujjj30V-jS1 (with incremental encoder) Note Refer to Chapter 5 Specifications for connector and cable specifications. 2-31 Chapter 2 System Design and Installation 2-3-2 Wiring Servo Drivers Provide proper wire diameters, ground systems, and noise resistance when wiring terminal blocks. H Wiring Terminal Blocks • R88D-UT24V-j/UT40V-j/UT60V-j/UT80V-j Power Cable Control Circuit Power Supply Single-phase 200/230 VAC 50/60 Hz Red White Black Green The cable is of IP30 construction. If more protection is required or to conform to the EC Directives, use the recommended connectors. Refer to 2-1-2 Installation Conditions. Brown 24 VDC ±10% No polarity Yellow Signal line for brake Class-3 ground min. 2-32 (1 kW to 2 kW) R88A-CAUBjjjS (for motor without brake) R88A-CAUBjjjB (for motor with brake) (3 kW to 5 kW) R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) Main Circuit Power Supply Three-phase 200/230 VAC 50/60 Hz Chapter 2 System Design and Installation • R88D-UT110V Control Circuit Power Supply Single-phase 200/230 VAC 50/60 Hz Main Circuit Power Supply Three-phase 200/230 VAC 50/60 Hz Class-3 ground min. Red Green White Black Power Cable R88A-CAUCjjjS (for motor without brake) R88A-CAUCjjjB (for motor with brake) The cable is of IP30 construction. If more protection is required or to conform to the EC Directives, use the recommended connectors. Refer to 2-1-2 Installation Conditions. Brown Signal line for brake Yellow 24 VDC ±10% No polarity 2-33 Chapter 2 System Design and Installation Terminal label Name Frame ground Main circuit power supply l input L1 L2 L3 L1C Control circuit power supply input Main circuit DC output (positive) L3C + (+1) B Function This is the ground terminal. Ground to a class-3 ground (to 100 Ω or less) or better. Three-phase 200/230 VAC ((170 to 253 V), ), 50/60 Hz Single-phase 200/230 VAC (170 to 253 V), 50/60 Hz Be sure to connect a regenerative resistor (corresponding to the amount of regenerative energy) between the + and B terminals for the R88D-UTjV-RG and between the +1 and B terminals for the R88D-UT110V. Refer to 3-6-3 Absorption of Regenerative Energy with External Regenerative Resistors Connected to Models Complying with EC Directives for details. Do not connect anything to these terminals of any other models. – Main circuit DC output (negative) U V W Motor connection Red These are the output terminals to the Servomotor. Be careful to wire terminals i l h correctly. l White them Black Frame ground Green H Terminal Block Current and Wire Sizes The following table shows the rated effective currents flowing to the Servo Driver and the sizes of the electrical wires. Driver (Watts) R88D-UT24Vj (1.0 kW) R88D-UT40Vj (1.5 kW) Main circuit power supply ly in input ut (L1, L2, L3) Effective current 6.6 A Wire size 3.5 mm2 or AWG 12 min. Control circuit power supply su ly input (L1C, L3C) Effective current 0.25 A Motor connection teri l (U, (U minal V, V W) Effective current 6.1 A Wire size 3.5 mm2 or AWG 12 9.2 A 0.25 A R88D-UT60Vj (2.0 kW) 13.0 A R88D-UT80Vj (3.0 kW) 18.4 A R88D-UT110V (4.0 kW) R88D-UT110V (5.0 kW) 24.0 A 28.0 A 5.5 mm2 or AWG 10 min. 0.25 A 0.25 A 0.25 A 0.25 A 25.3 A 26.2 A 1.25 mm2 or AWG 16 min. Wire size 9.9 A 12.0 A 19.4 A 5.5 mm2 or AWG 10 min. Use OMRON standard cables. Frame ground Motor connector’s applicable cable size AWG 14 to AWG 12 Wire size Use 2.0-mm2 external ground wires. Use the same wire as used for the motor output. Terminal block screw size 2-34 M4 AWG 10 to AWG 8 Chapter 2 System Design and Installation H Wire Sizes and Allowable Current The following table shows allowable currents when there are three electrical wires. Use values equal to or lower than the specified values. D 600-V Heat-resistant Vinyl Wiring (HIV) (Reference Values) AWG size 16 14 12 10 8 6 Nominal crosssectional area 2) ( (mm Configuration ((wires/mm2) 1.25 2.0 3.5 5.5 8.0 14.0 7/0.45 7/0.6 7/0.8 7/1.0 7/1.2 7/1.6 Conductive resistance (Ω/k ) (Ω/km) 17.5 9.53 5.41 3.47 2.41 1.35 Allowable current (A) for ambient temperature 30°C 16 23 33 43 55 79 40°C 14 20 29 38 49 70 50°C 11 16 24 31 40 57 2-3-3 Wiring Conditions Satisfying EMC Directives Models complying with EC Directives must abide by the following wiring conditions to satisfy EMC Directive EN55011 (EMI) Class A, group I and EN50082-2 requirements (EMS). If the models cannot abide by the conditions because the models are built into equipment, the equipment must be completely examined to make sure that the equipment satisfies EC Directives. S The Servo Driver must be mounted to a metal panel (i.e., a control panel). S The power supply line must be connected to a noise filter and a surge absorber to protect the power supply lines from lightning or any other surge. S The I/O signal and encoder signal lines must be constructed of cables with braided shield wire made of tin-coated annealed copper. S Any cable from the control panel must be protected with a metal conduit or braided conduit. S All cables with braided shield wire must be attached with ferrite cores and the shield wire must be grounded directly to the ground plate from the clamps. S The power supply must be equipped with a transformer if the Servo Driver is a 4- or 5-kW model. 2-35 Chapter 2 System Design and Installation H Wiring Method Control panel Device with built-in motor Metal plate Metal or braided conduit AC power supply 0.5 m max. 2 m max. Transformer (see note 3) Power supply for brake use Ferrite core Contactor Surge absorber Metal or braided conduit Noise filter Ground at a resistance of less than 100 Ω. Ferrite core Controller power supply 1 m max. 0.5 m max. Clamp Controller 1 m max. Ground plate Ferrite core Ferrite core Clamp Ferrite core Controller Note 1. The cables must be coiled around each ferrite core by 1.5 turns. Note 2. At the clamp positions, the shield wire of the cables must be stripped and grounded directly to the ground plate. Note 3. The power supply must be equipped with a transformer if the Servo Driver is a 4- or 5-kW model. • Ground the motor’s frame to the machine ground when the motor is on a movable shaft. • Use a grounding plate for grounding the protective earth (PE) terminal of each Unit as shown in the illustration, and ground to a single point. • Use ground lines with a minimum thickness of 3.5 mm2, and arrange the wiring so that the ground lines are as short as possible. • If no-fuse breakers are installed at the top and the power supply line is wired from the lower duct, use metal tubes for wiring and make sure that there is adequate distance between the input lines and the internal wiring. If input and output lines are wired together, noise resistance will decrease. • No-fuse breakers, surge absorbers, and noise filters (NF) should be positioned near the input terminal block (ground plate), and I/O lines should be isolated and wired using the shortest means possible. 2-36 Chapter 2 System Design and Installation • Wire the noise filter as shown at the left in the following illustration. The noise filter should be installed at the entrance to the control panel whenever possible. Good: Separate input and output AC input NF 1 4 2 3 5 6 E NO: Noise not filtered effectively NF AC output AC input Ground 1 4 2 3 5 6 E Ground AC output • Use twisted-pair cables for the power supply cables whenever possible, or bind the cables. L1 L1C Driver L2 L3 or L3C Driver Binding • Separate power supply cables and signal cables when wiring. H Construction of Control Panel The control panel will leak electromagnetic energy or permit the interior of the control panel to be affected by external electromagnetic fields if there is a space around any cable inlet or outlet, mounting hole, or door of the control panel. To prevent electromagnetic energy leakage from the control panel or external electromagnetic influence on the interior of the control panel, follow the instructions below before designing or selecting the control panel. D Casing Construction • The control panel must be made of metal plates, each of which must be connected by welding so that the plates will be all in contact together electrically. • If the control panel is an assembly type consisting of metal plates connected to one another with screws, be sure to remove the surface paint coating of each joint portion so that the plates will be all in contact together electrically. • Be sure to tighten the screws properly so that the metal plates will not be warped. • Make sure that control panel has no part that is electrically isolated. • All units mounted inside the control panel must be grounded to the control panel. 2-37 Chapter 2 System Design and Installation D Door Construction • The door must be made of metal. • The space between the door and casing must be of watertight construction as shown below. • Apply conductive packing to the space between the casing and door as shown below. Be sure to remove the surface paint coating of the portion of the casing and that of the door coming into contact with the conductive packing so that the door, conductive packing, and casing will be all in contact electrically. • Be sure to tighten the screws properly so that the metal plates of the control panel will not be warped. Casing Door Casing side Door side Oil-proof packing Conductive packing A-B Cross-section Control panel Oil-proof packing Conductive packing Door (inner side) H Selecting Components This section describes standards to be considered when selecting components to be connected to reduce noise. Select components after reviewing characteristics such as capacities, performance, and application ranges. Recommended components are listed below for reference. For further details, consult the respective manufacturer. 2-38 Chapter 2 System Design and Installation D No-fuse Breakers (MCCB) When selecting no-fuse breakers, take into consideration the maximum input current and the inrush current. The momentary maximum output for a servo system is approximately three times that of the rated output, and a maximum output of three seconds can be executed. Therefore, select no-fuse breakers with an operating time of at least five seconds at 300% of the rated maximum output. Generalpurpose and low-speed no-fuse breakers are generally suitable. Refer to the table in 2-2-2 Terminal Block Wiring for the power supply input currents for each motor, and then add the current consumption for the number of shafts, other controllers, etc., to make the selection. The Servo Driver inrush current flows at a maximum of 50 A for 20 ms when 200 V is input. With lowspeed no-fuse breakers, a inrush current 7 to 8 times the rated current flows for 0.1 second. When making the selection, take into consideration the entire inrush current for the system. D Surge Absorbers Use surge absorbers to absorb surges from power supply input lines due to lightning, abnormal voltages, etc. When selecting surge absorbers, take into account the varistor voltage, the amount of surge immunity, and the amount of energy resistance. For the 200-VAC series, use one with varistor voltage of 470 V. The surge absorbers shown in the following table are recommended. Maker Okaya Electric Ind. d Model R.A.V-781BYZ-2 Max. limit voltage 783 V Surge immunity 1,000 A R.A.V-781BXZ-4 783 V 1,000 A Type Block Remarks Between power lines Between the power line and grounding Note 1. Refer to manufacturers documentation for operating details. Note 2. The surge immunity is for a standard impulse current of 8/20 µs. If pulses are wide, either decrease the current or change to a larger-capacity surge absorber. D Noise Filters Apply one of the following Schaffner Noise Filters to the power supply for the Servo Driver. Application Model Rated current (at 40 _C) 1.0/1.5 kW FN351-16/29 16 A 2.0 kW FN351-25/29 25 A 3.0 kW FN351-36/33 36 A 4.0/5.0 kW FN351-50-33 50 A Rated voltage 440 V Test voltage 2,250 VDC for 2 seconds b t between th the terminal and case 1,100 VDC for 2 seconds between the terminals Leakage current (at 400 V, 50 Hz max.) (See note) 17.5 mA 160 mA 160 mA 175 mA Note The leakage current values shown in the table indicate those for star-connection (Y-connection) three-phase power supply. For the delta-connection (∆-connection) power supply, the values may become larger than those shown in the table. 2-39 System Design and Installation Chapter 2 Dimensions Use the following noise filter on the power supply for the brake. This filter is manufactured by Okaya Electric Ind. Model Rated current Test voltage SUP-P5H-EPR-4 5A Between terminals and case: 2,000 V rms, 50/60 Hz, 60 s Between terminals: 1,250 V rms, 50/60 Hz, 60 s Insulation resistance Between terminals and case: 6,000 MΩ min. (at 500 VDC) Leakage current 0.6 mA (at 250 V rms 60 Hz) Attenuation Normal mode: 0.5 to 30 MHz characteristics Common mode: 0.2 to 30 MHz Dimensions Two, 4.8 dia. 2-40 Chapter 2 System Design and Installation D Surge Killers Install surge killers for loads that have induction coils, such as relays, solenoids, brakes, clutches, etc. The following table shows types of surge killers and recommended products. Type Diode Features Diodes are relatively small devices such as relays used for loads when reset time is not an issue. The reset time is increased because the surge voltage is the lowest when power is cut off. Used for 24/48-VDC systems. Thyristor or Varistor Thyristor and varistor are used for loads when induction coils are large, as in electromagnetic brakes, solenoids, etc., and when reset time is an issue. The surge voltage when power is cut off is approximately 1.5 times that of the varistor. Capacitor + resistor Use capacitors and resistors for vibration absorption of surge when power is cut off. The reset time can be shortened by proper selection of the capacitor or resistor. Recommended products Use a fast-recovery diode with a short reverse recovery time. Fuji Electric Co., ERB44-06 or equivalent Select varistor voltage as follows: 24-VDC system varistor: 100-VDC system varistor: 100-VAC system varistor: 200-VAC system varistor: Okaya Electric Ind. 39 V 200 V 270 V 470 V CR-50500 0.5 µF-50 Ω CRE-50500 0.5 µF-50 Ω S2-A-0 0.2 µF-500 Ω Note Thyristors and varistors are made by the following companies. Refer to manufacturers documentation for operating details. Thyristors: Ishizuka Electronics Co. Varistors: Ishizuka Electronics Co., Matsushita Electric Parts D Contactors When selecting contactors, take into consideration the circuit’s inrush current and the momentary maximum current. The Servo Driver inrush current is 50 A, and the momentary maximum current is approximately twice the rated current. The following table shows the recommended contactors. Maker OMRON Model LC1D25106 LC1D40116 LC1D50116 LC1D80116 LP1D25106 LP1D40116 LP1D50116 LP1D80116 Rated current 26 A 35 A 50 A 80 A 26 A 35 A 50 A 80 A Coil voltage 200 VAC 24 VDC D Leakage Breakers Select leakage breakers designed for inverters. Since switching takes place inside the Servo Drivers, high-frequency current leaks from the armature of the motor. With inverter leakage breakers, high-frequency current is not detected, preventing the breaker from operating due to leakage current. When selecting leakage breakers, remember to also add the leakage current from devices other than the Servomotor, such as machines using a switching power supply, noise filters, inverters, and so on. When selecting leakage breakers, refer to the manufacturer’s catalog. 2-41 Chapter 2 System Design and Installation The following table shows leakage current of each Servomotor. Driver Leakage current (direct measurement) (including high-frequency current) R88D-UT24V-j R88D-UT40V-j R88D-UT60V-j R88D-UT80V-j R88D-UT110V 50 mA Leakage current (resistor/capacitor measurement) (commercial power supply frequency range) 6 mA 70 mA 7 mA 100 mA 12 mA Note 1. The above leakage current is for cases where motor power line length is less than 10 m. (It varies depending on the power line length and insulation.) Note 2. The above leakage current is for normal temperature and humidity. (It varies depending on the temperature and humidity.) H Improving Encoder Cable Noise Resistance Signals from the encoder are either A, B, or S phase (Z phase). The frequency for A- or B-phase signals is either 307.2 kHz (if an incremental encoder is used) or 614.4 kHz (if an absolute encoder is used), while the transmission speed for S-phase signals is 1.23 Mbps. Follow the wiring methods outlined below to improve encoder noise resistance. • Be sure to use dedicated encoder cables. • If lines are interrupted in the middle, be sure to connect them with connectors, making sure that the cable insulation is not peeled off for more than 50 mm. In addition, be sure to use shielded wire. • Do not coil cables. If cables are long and are coiled, mutual induction and inductance will increase and will cause malfunctions. Be sure to use cables fully extended. • When installing noise filters for encoder cables, use clamp cables. The following table shows the recommended clamp filter models. Maker Tokin TDK Name EMI core Clamp filter Model ESD-QR-25-1 ZCAT2032-0930 ZCAT3035-1330 ZCAT2035-0930A • Do not wire the encoder cable in the same duct as power cables and control cables for brakes, solenoids, clutches, and valves. H Improving Control I/O Signal Noise Resistance Position can be affected if control I/O signals are influenced by noise. Follow the methods outlined below for the power supply and wiring. • Use completely separate power supplies for the control power supply (especially 24 VDC) and the external operation power supply. In particular, be careful not to connect two power supply ground wires. Install a noise filter on the primary side of the control power supply. • As much as possible, keep the power supply for pulse command and deviation counter reset input lines separate from the control power supply. Be particularly careful not to connect the two power supply ground lines. 2-42 System Design and Installation Chapter 2 • It is recommended that a line driver be used for pulse command and deviation counter reset outputs. • Be sure to use twisted-pair shielded wire for pulse command and deviation counter reset signal lines, and connect both ends of the wires to frame grounds. • For speed and torque command input lines, be sure to use twisted-pair shielded cable, and connect both ends of the shield wire to ground. • If the control power supply wiring is long, noise resistance can be improved by adding 1-µF laminated ceramic capacitors between the control power supply and ground at the Servo Driver input section and the controller output section. • For encoder output (A, B, and Z phase) lines, be sure to use twisted-pair shielded cable, and connect both ends of the shield wire to ground. • For open collector specifications, keep the length of wires to within one meter. 2-43 Chapter 2 System Design and Installation 2-3-4 Peripheral Device Connection Examples L1 L2 L3 Three-phase, 200/230 VAC, 50/60 Hz NFB 1 E 4 2 3 NF 5 6 Noise filter Main-circuit power supply OFF Main-circuit connector ON 1MC Class-3 ground 1MC X Thermal switch contact* Surge killer R88A-RR22047S Regenerative Resistor OMNUC U-series AC Servo Driver 1MC *Regenerative Resistor can be connected externally only for models with a suffix of “-RG” and R88D-UT110V. L1C +1 L3C B Thermal switch contact R88A-CAUBjjjS/-CAUCjjjS (-CAUBjjjB/-CAUCjjjB) Power Cable OMNUC U-series AC Servomotor XB L1 L2 B 24VDC L3 U Class-3 ground V CN1 X M 31 ALM W 24 VDC 32 ALMCOM User’s control device X CN2 R88A-CRUBjjjC Encoder Cable E CN1 CN1 BKIR 27 XB 24 VDC OGND 28 (Note: Set by user parameter Cn-2d.) 2-44 3 Chapter 3 Operation 3-1 3-2 3-3 3-4 3-5 3-6 Beginning Operation System Check Mode (Cn-00) Function Settings Trial Operation Making Adjustments Regenerative Energy Absorption Chapter 3 Operation Operation and Adjustment Precautions ! Caution Check the newly set parameters for proper execution before actually running them. Not doing so may result in equipment damage. ! Caution Do not make any extreme adjustments or setting changes. Doing so may result in unstable operation and injury. ! Caution Separate the Servomotor from the machine, check for proper operation, and then connect to the machine. Not doing so may cause injury. ! Caution When an alarm occurs, remove the cause, reset the alarm after confirming safety, and then resume operation. Not doing so may result in injury. ! Caution Do not come close to the machine immediately after resetting momentary power interruption to avoid an unexpected restart. (Take appropriate measures to secure safety against an unexpected restart.) Doing so may result in injury. ! Caution Do not use the built-in brake of the Servomotor for ordinary braking. Doing so may result in malfunction. 3-2 Operation 3-1 Chapter 3 Beginning Operation 3-1-1 Operational Procedure Before beginning operation, be sure to make the initial settings for the Servo Driver. Make function settings as required according to the use of the Servomotor. H Startup Procedure 1. Mounting and installation Install the Servomotor and Servo Driver according to the installation conditions: Chapter 2, section 2-1. 2. Wiring and connections Connect to power supply and peripheral devices. Specified installation and wiring requirements must be satisfied, particularly for models conforming to the EC Directives: Chapter 2, sections 2-2 and 2-3. 3. Turning on power supply Before turning on the power supply, check the necessary items. In order to make the initial settings, turn on an application power supply: Chapter 3, section 3-1-2 and Chapter 4, section 4-1. 4. Checking display status Check by means of the displays to see whether there are any internal errors in the Servo Driver: Chapter 3, section 3-1-2 5. Initial settings Make the settings for the operation setup parameters (initial settings): Chapter 3, section 3-3-1. 6. Function settings By means of the user parameters, set the functions according to the operating conditions: Chapter 3, section 3-3-2. 7. Trial operation Check to see whether protective functions such as emergency stop and operational limits are working reliably. Check operation at both low speed and high speed: Chapter 3, section 3-4. 8. Adjustments Execute auto-tuning. Manually adjust the gain as required: Chapter 3, section 3-5. 9. Operation Operation can now begin. If any trouble should occur, refer to Chapter 4 Application: Chapter 4. 3-3 Chapter 3 Operation 3-1-2 Turning On Power and Checking Displays H Items to Check Before Turning On Power D Checking Power Supply Voltage • Check to be sure that the power supply voltage is within the ranges shown below. Main-circuit power supply: Three-phase 200/230 VAC (170 to 253 V) 50/60 Hz Control-circuit power supply: Single-phase 200/230 VAC (170 to 253 V) 50/60 Hz D Checking Terminal Block Wiring • The main-circuit power supply inputs (R/S/T or L1/L2/L3) and the control-circuit power supply inputs (r/t or L1C/L3C) must be properly connected to the terminal block. • The Servomotor’s red (U), white (V), and black (W) power lines and the green ground wire ( ) must be properly connected to the terminal block. D Checking the Servomotor • There should be no load on the Servomotor. (Do not connect to the mechanical system.) • The power line connectors at the Servomotor must be securely connected. D Checking the Encoder Connectors • The encoder connectors (CN2) at the Servo Driver must be securely connected. • The encoder connectors at the Servomotor must be securely connected. D Checking the Control Connectors • The control connectors must be securely connected. • The operation command (RUN) must be OFF. D Checking Parameter Unit Connections • The Parameter Unit (R88A-PR02U or R88A-PR03U) must be securely connected to the CN3 connector. H Turning On Power • First carry out the preliminary checks, and then turn on the control-circuit power supply. It makes no difference whether or not the main-circuit power supply is also turned on. 3-4 Chapter 3 Operation H Checking Displays • When the power is turned on, one of the codes shown below will be displayed. Normal (Base Block) Error (Alarm Display) b b 0 2 Note 1. “Baseblock” means that the Servomotor is not receiving power. Note 2. The alarm code (the number shown in the alarm display) changes depending on the contents of the error. • If the display is normal (i.e., no errors), use it as a monitor mode speed display. Manually turn the Servomotor shaft clockwise and counterclockwise, and check to be sure that it agrees with the positive and negative on the speed display. If it does not agree, then the encoder signal line may be wired incorrectly. Reverse rotation Display example Forward rotation 0038 Forward rotation Ć0 0 2 5 Reverse rotation Note To monitor the speed feedback value, press the MODE/SET Key and go into monitor mode u n Ć 0 0 . Then press the DATA Key. • If there is an error, refer to Chapter 4 Application and take the necessary countermeasures. 3-5 Chapter 3 Operation 3-1-3 Using Parameter Units The key operations for the Handy-type R88A-PR02U and the Mounted-type R88A-PR03U vary depending on the functions used. The same settings and operations are possible with either Parameter Unit. H Parameter Unit Keys and Functions Handy-type R88A-PR02U Mounted-type R88A-PR03U PR02U PR03U RESET + SERVO DATA DATA DATA Function Alarm reset Mode switching Data memory Servo ON/OFF during jog operations Switching between parameter display and data display; data memory Increments parameter numbers and data values. Decrements parameter numbers and data values. Left shift for operation digits Right shift for operation digits H Modes Mode Status display mode Settings mode Monitor mode Alarm history display mode 3-6 Function Control-circuit power supply ON display, main-circuit power supply ON display, baseblock, in position, speed conformity, rotation detection, command pulses being input, speed command being input, torque command being input, deviation counter reset signal being input Symbol display: Baseblock, operating, forward rotation prohibited, reverse rotation prohibited, alarm display System check: Jog operations, command offset automatic adjustment, alarm history data clear, command offset manual adjustment, motor parameters check, auto-tuning Setting and checking setup parameters Setting and checking user parameters Speed feedback, speed commands, torque commands, number of pulses from U-phase, electrical angle, internal status bit display, command pulse speed display, position displacement, input pulse counter Displays contents of alarms that have been previously generated (up to a maximum of 10). Bit display: Chapter 3 Operation H Changing Modes To change modes, press the MODE/SET Key. Power ON (Display example) Status display mode Ć. bb Settings mode Monitor mode Alarm history display mode c n Ć0 0 u n Ć0 0 0 Ć a.0 2 3-7 Chapter 3 Operation H Mode Changes and Display Contents Power ON Status display mode (Display example) Ć. Bit Displays Control-circuit power ON Main-circuit power ON Base block (motor not receiving power) In position / Speed conformity Torque commands being input / Deviation counter reset signal being input Command pulses being input / Speed commands being input Motor rotation detected Symbol Displays bb DATA Settings mode c n Ć 0 0 System check mode DATA DATA Setup parameter no. 2 c n Ć 0 2 User parameters c n Ć 0 3 c n Ć 2 d Monitor mode Alarm history display mode 3-8 b Base block n In operation (running) t Forward rotation prohibited t Reverse rotation prohibited j Alarm display Jog operation Command offset automatic adjustment Clear alarm history data Command offset manual adjustment Motor parameters check Auto-tuning Setup parameter no. 1 c n Ć 0 1 b r U p % n % a. j Sequence input signal switch Abnormal stop selection Deviation counter for servo OFF P control switch selection P control switch conditions Encoder selection Reverse mode Origin error mask Speed limit by analog input Command pulse mode Monitor switch 1 Monitor switch 2 TREF switch Torque feed-forward function selection Deviation counter clear Torque command filter constant Command pulse logic reversal Parameter Unit monitor level switch Speed command scale Unit number setting u n Ć 0 0 Speed feedback u n Ć 0 9 Internal pulse counter 0 Ć a. j j Error one time before 9 Ć a. j j Error ten time before Chapter 3 Operation 3-2 System Check Mode (Cn-00) The various kinds of system checks can be carried out by setting data for parameter Cn-00. In system check mode, the following six kinds of checks can be carried out according to the data set for Cn-00. This chapter explains these checks only in a general way. For details, see the references noted in the table below. Set value 00 Contents of check Jog operation 01 Command offset automatic adjustment 02 Alarm history data clear 03 04 Command offset manual adjustment Motor parameter check 05 Auto-tuning Explanation The motor can be operated by the Parameter Unit. The rotation speed is set by user parameter Cn-10 (jog speed). Automatically adjusts speed command and torque command input offset. Treat speed command and torque command inputs as 0 V. Clears history data for alarms that were previously generated. Speed command input offset is adjusted manually. References Section 3-4 Section 3-5-3 Section 4-4-1 Section 3-5-3 Checks whether the Servo Driver and Servomotor Section 4-2-4 are correctly aligned. Operates the motor and automatically adjusts the Section 3-5-1 position loop gain, speed loop gain, and speed loop integration constant. The rotation speed is 1/2 of that set by the user parameter Cn-10 (jog speed). 3-9 Chapter 3 Operation 3-3 Function Settings 3-3-1 Setting and Checking Setup Parameters (Cn-01, 02) Setup parameters are parameters that are essential for starting up the system. They include I/O signal function changes, selection of processing for momentary stops and errors, control mode changes, and so on. Set them to match the user system. Once the parameters have been set, they become effective when the power supply is turned on again after having been turned off. (Check to see that the LED display has gone off.) H Displaying Setup Parameters To display the contents of setup parameters, execute the following key operations. • To go into settings mode (cnĆ00), press the MODE/SET Key. • To display the setup parameter number (cnĆ01 or cnĆ02), press the Up and Down keys. • To display the contents of the setup parameter, press the DATA key. H Setting Setup Parameters The contents of the setup parameters are displayed as follows: E C A 8 6 4 2 0 0 Bit no. F d b 9 7 5 3 1 Bit no. to be set. In the leftmost four digits, 16 bits of information are displayed. In the rightmost digit, the bit number that can be set is displayed. It can be checked whether the bit information is “0” (not lit) or “1” (lit), according to the 7-segment LED vertical bar. To change the set value, first set the bit number in the rightmost digit, and then set the appropriate bit to “0” or “1.” D Making Settings with Handy-type (R88A-PR02U) 1. Use the Right and Left Keys to display in the rightmost digit the bit number that is to be set. 2. Using the Up (or Down) Key, reverse the lit/not lit status of the appropriate bit number. For “lit,” set the bit number to “1.” For “not lit,” set it to “0.” 3. Repeat steps 1 and 2 above as required. 4. Save the data in memory by pressing the MODE/SET Key (or the DATA Key). 5. With this, the parameter setting operation is complete. Pressing the DATA Key at this point will bring back the parameter number display. 6. To go from the settings mode to the monitor mode, press the MODE/SET Key. D Making Settings with Mounted-type (R88A-PR03U) 1. Use the Up and Down Keys to display in the rightmost digit the bit number that is to be set. 2. Using the MODE/SET Key, reverse the lit/not lit status of the appropriate bit number. For “lit,” set the bit number to “1.” For “not lit,” set it to “0.” 3. Repeat steps 1 and 2 above as required. 4. Save the data in memory by pressing the DATA Key. 5. With this, the parameter setting operation is complete. Pressing the DATA Key at this point will bring back the parameter number display. 6. To go from the settings mode to the monitor mode, press the MODE/SET Key. 3-10 Chapter 3 Operation H Setup Parameter Contents D Setup Parameter No. 1 (Cn-01) Item Bit no. Factory setting Setting Explanation Sequence q input signal g switching i hi 0 0 1 [Ab l ] [Absolute] 0 0 1 0 1 Servo turned ON or OFF by Run command (externally input). Servo always ON. Enables sensor-on input (externally input). Automatically regards as high level internally, regardless of sensor-on input signal. 2 1 3 1 4 0 5 6 0 1 7 (Note 1) (N ((Note 3)) 8 0 Abnormal stop selection i 9 Deviation counter for servo OFF A 0 0 P control switch selection i b 1 P control switch conditions d, C ( (Note 4)) 0, 0 Encoder selection E [Absolute] [Ab l ] 0 F 0 0 1 0 1 ––– Enables forward drive prohibit input (POT). Permits always-forward drive. Enables reverse drive prohibit input (NOT). Permits always-reverse drive. Not used. ––– Not used. 0 1 0 1 0 Motor stopped by dynamic brake. Motor stopped with free run. Dynamic brake OFF after motor stopped. Dynamic brake ON after motor stopped. Method for stopping when over-travel occurs depends on bit no. 6 setting. 1 When over-travel occurs, motor is stopped at the torque set by user parameter Cn-06 (emergency stop torque). 0 When over-travel occurs, motor comes to deceleration stop and servo turns OFF. 1 When over-travel occurs, motor comes to deceleration stop and position is locked. 0 Deviation counter cleared when servo is OFF and alarm is generated. 1 Deviation counter not cleared when servo is OFF and alarm is generated. 0 1 0, 0 Switch function enabled; follows bit nos. C, d. No switch function. The torque command value (Cn-0C) is taken as the condition. 0, 1 1, 0 The speed command value (Cn-0d) is taken as the condition The acceleration command value (Cn-0E) is taken as the condition. 1, 1 0 1 ––– The deviation pulse (Cn-0F) is taken as the condition. Incremental encoder Absolute encoder Not used. Note 1. If set bit 6 to “1” and bit 8 to “0,” the dynamic brake relay will turn OFF after the Servomotor stops, regardless of the setting of bit no. 7. Note 2. In the torque control mode, the method of stopping for errors depends on the setting of bit no. 6. The setting of bit no. 8 has no effect. Note 3. The factory settings (i.e., the default settings) for Cn-01 bit no. 7 are as follows: 1: 1.0 kW and 1.5 kW motors 0: Motors of 2.0 kW and over. The Cn-01 bit no. 7 setting is valid only for 1.0 kW and 1.5 kW motors. 3-11 Chapter 3 Operation Note 4. With P control switch conditions, a change from PI control to P control is selected. This function is not valid for torque control. Note 5. Do not change the settings of bit nos. 4, 5, and F of setup parameter no. 1 (Cn-01). Note 6. These parameters become effective only after power is reset. Confirm that the indicators go out before turning power back on. (Check to see that the LED display has gone off.) D Setup Parameter No. 2 (Cn-02) Item Bit no. Factory setting Setting 0 0 1 [Ab l ] [Absolute] 0 2 0 5,, 4,, 3 0,, 0,, 1 Monitor switch 1 6 0 0 1 0 1 0 1 0, 0, 0 0, 0, 1 0, 1, 0 0, 1, 1 1, 0, 0 0 1 Monitor switch 2 7 0 0 1 NM terminal is taken as speed monitor output terminal. NM terminal is taken as deviation counter monitor output terminal. (See note 4.) TREF switch (for ( speed control) l) 8 0 Torque feed-forward function selection (for speed control) 9 0 0 1 0 Current limit is disabled by TREF. Current limit is enabled by TREF. No torque feed-forward function. 1 Torque feed-forward function enabled. Deviation counter clear (f position (for i i control) l) A 1 b C 0 0 Command pulse logic reversal (for position control) d 0 Parameter Unit monitor level switch (for position control) E Reverse rotation mode Origin g error mask Speed limit by y analog g i input (f torque control) (for l) Command pulse mode Torque q command filter d degree F 0 0 0 1 ––– Explanation CCW direction is taken upon “+” command. (See note 5.) CW direction is taken upon “+” command. Origin errors are detected. Origin errors are not detected. Disabled. Enabled. Feed pulses / Forward/reverse signal Forward pulses / Reverse pulses 90° phase difference (A/B phase) signal (x1) 90° phase difference (A/B phase) signal (x2) 90° phase difference (A/B phase) signal (x4) AM terminal is taken as current monitor output terminal. AM terminal is taken as speed command / command pulse speed monitor output terminal. (See note 3.) Deviation countered cleared by status (high level). Deviation countered cleared by differentiation (rising edge). Not used. 0 1 0 Primary filter Secondary filter Positive logic 1 Negative logic 0 Deviation monitor taken as x1 command units. 1 Deviation monitor taken as x100 command units. ––– Not used. Note 1. Do not change the settings of bit nos. b and F of setup parameter no. 2 (Cn-02). Note 2. Parameters other than bit nos. 6 and 7 of setup parameter no. 2 (Cn-02) become effective only after power is reset. Confirm that the indicators go out before turning power back on. (Check to see that the LED display has gone off.) 3-12 Chapter 3 Operation Note 3. The function will vary depending on the control mode that is selected. Position control: Command pulse speed monitor (1 V @ 1,000 r/min) Speed control: Speed command monitor (1 V @ 1,000 r/min) Torque control: (Disabled: 0 V) Note 4. The function will vary depending on the control mode that is selected. Position control: Deviation counter monitor (when 0.05 V @ command unit: Cn-02 bit no. E = 0) Speed control: (Disabled: 0 V) Torque control: (Disabled: 0 V) Note 5. CCW direction refers to counterclockwise rotation and CW direction refers to clockwise rotation when viewed from the motor output side. D Important Setup Parameters (Cn-01 and Cn-02) This section explains the particularly important setup parameters. If these parameters aren’t set properly, the motor might not operate or might operate unpredictably. Set these parameters appropriately for the system being used. Command Pulse Types (for Position Control, Cn-02 Bit Nos. 5, 4, and 3) Set the command pulse mode for position control according to the pulse command configuration. Command pulse mode (Cn-02 bit nos. 5, 4, 3) 0, 0, 0 0, 0, 1 0, 1, 0 0, 1, 1 1, 0, 0 Selected command pulse mode Feed pulses (PULS) / Forward/reverse signal (SIGN) Forward pulses (CCW) / Reverse pulses (CW) (Factory setting) 90° phase difference (A/B phase) signal (x1) 90° phase difference (A/B phase) signal (x2) 90° phase difference (A/B phase) signal (x4) Note When a 90° phase difference signal is input, any of three types of multipliers can be selected: x1, x2, or x4. If x4 is selected, the input pulses will be multiplied by four, so the number of motor revolutions (speed, angle) will be four times that of x1. Error Stop Processes Bits 6, 7, 8, and 9 of Cn-01 specify how the motor will be stopped when the servo goes OFF (the run command is OFF), an alarm is generated, or overtravel occurs. The following diagrams show the function of these four bits: Stop Process for Servo OFF/Alarm Deceleration method Bit 6 Servo OFF or Alarm Bit 7 0 Decelerate by dynamic brake. 0 1 Stop condition Servo free (dynamic brake OFF) Servo free (dynamic brake ON) 1 Decelerate by free run. Servo free (dynamic brake OFF) Note Bit no. 7 is not valid for motors of 2.0 kW or more. At the time of stopping, the dynamic brake turns OFF. 3-13 Chapter 3 Operation Stop Process for Overtravel Deceleration method Stop condition Decelerate by dynamic brake. Servo free (dynamic brake OFF) Bit 6 Overtravel occurs. Bit 8 0 0 1 1 Decelerate by free run. Bit 9 Decelerate by emergency stop torque (Cn-06). Servo free (dynamic brake OFF) 0 1 Servo lock Encoder Selection (Cn-01 Bit No. E) Set this parameter according to the encoder for the Servo Motor that is used. The factory setting is for an incremental encoder (“0”). If an absolute encoder is to be used, set this parameter to “1.” Encoder selection (Cn-01 bit no. E) 0 1 3-14 Selected encoder Incremental encoder (factory setting) Absolute encoder Chapter 3 Operation 3-3-2 Setting and Checking User Parameters (Cn-03 to 2d) Execute the user parameter settings in order as follows: Go into settings mode . . . . . . . . . . . . . . . . . . . . . . . MODE/SET Key Display the pertinent parameter number . . . . . . . Direction Keys (Handy-type) Up and Down Keys (Mounted-type) Display the contents (data) of the parameter . . . . DATA Key Change the data . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direction Keys (Handy-type) Up and Down Keys (Mounted-type) Save the data in memory . . . . . . . . . . . . . . . . . . . . . MODE/SET and DATA Keys H Checking User Parameters The contents of a given user parameter can be checked by pressing the DATA Key while that parameter number is being displayed. Pressing the DATA Key again will bring back the parameter number display. (See the illustration below.) Parameter Number Display [1] [2] Data Display DATA c n Ć 0 3 0 0 3 0 0 DATA [5] [4] H Setting User Parameters Use the following procedures to set user parameters. D Making Settings with Handy-type (R88A-PR02U) 1. Use the Direction Keys to display the number of the parameter that is to be set. Using the Right and Left Keys, select the digit that is to be set. The digit for which the number can be changed will blink. With the Up and Down Keys, increment or decrement the number for that digit. 2. Press the DATA Key. The contents (data) of the pertinent parameter will be displayed. 3. Using the Direction Keys, set the data. The method is the same as for step 1 above. 4. Save the data in memory by pressing the MODE/SET Key (or the DATA Key). 5. Pressing the DATA Key again will bring back the parameter number display. 6. Repeat steps 1 through 5 above as required. D Making Settings with Mounted-type (R88A-PR03U) 1. Use the Up and Down keys to display the number of the parameter that is to be set. 2. Press the DATA Key. The contents (data) of the pertinent parameter will be displayed. 3. Using the Up and Down Keys, set the data. If the keys are held down, the numbers will change 10 at a time. If the keys are held down even longer, the numbers will change 100 and then 1,000 at a time. 4. Save the data in memory by pressing the MODE/SET Key (or the DATA Key). 5. Pressing the DATA Key again will bring back the parameter number display. 6. Repeat steps 1 through 5 above as required. 3-15 Chapter 3 Operation H User Parameter Chart PRM No. Cn-00 System check mode Factory setting --- --- --- Cn-01 Setup parameter no. 1 --- --- --- Cn-02 Setup parameter no. 2 --- --- --- Cn-03 Speed command scale 300 (r/min)/V 10 to 2,000 Cn-04 Speed loop gain (See note 1.) Speed loop integration constant Emergency stop torque 80 Hz 1 to 2,000 2,000 0.01 ms 200 to 51,200 0 to 350 0 Cn-08 Soft start acceleration time (Note 4) Forward torque limit Cn-09 Reverse torque limit 350 Cn-0A Encoder divider rate (See 1,000 note 2.) Rotation speed for motor 20 rotation detection P control switching (torque 200 commands) Cn-05 Cn-06 Cn-07 Cn-0b Cn-0C Parameter name 350 350 Cn-0d P control switching (speed 0 commands) Cn-0E P control switching (acceleration commands) 0 Cn-0F P control switching (deviation pulses) 10 Cn-10 Jog speed 500 Cn-11 Cn-12 Number of encoder pulses 4,096 (Notes 2 and 5) Brake timing 1 0 Cn-13 Torque command scale 30 Cn-14 Speed limit 3,000 3-16 Unit Setting range Explanation Refer to system check mode explanation. Refer to setup parameter no. 1 explanation. Refer to setup parameter no. 2 explanation. Rotation speed setting per 1 V of speed command voltage. Adjusts speed loop response. Speed loop integration constant % Deceleration torque when abnormality occurs (compared to rated torque). ms 0 to 10,000 Acceleration time setting for software start. % 0 to 350 Output torque for rotation in forward direction (compared to rated torque). % 0 to 350 Output torque for rotation in reverse direction (compared to rated torque). Pulses/ 16 to 8,192 Setting for number of output revolution (Note 6) pulses from Servo Driver. r/min 1 to 4,500 Setting for rotation speed for motor rotor detection output. % 0 to 350 If a torque command exceeds this value, the mode switches from PI to P control. r/min 0 to 4,500 If a speed command exceeds this value, the mode switches from PI to P control. 10 0 to 3,000 If an acceleration command (r/min)/s exceeds this value, the mode switches from PI to P control. Com0 to 10,000 If the deviation pulses exceed mand this value, the mode switches from PI to P control. r/min 0 to 4,500 Setting for manual rotation speed Pulses/ [INC]: 4,096 Setting for number of pulses revolution [ABS]: 8,192 for encoder used. 10 ms 0 to 50 Delay time setting from brake command until servo turns off. 0.1 10 to 100 Sets gain for torque command V/rated input. torque r/min 0 to 4,500 Sets speed limit value for torque control mode. Chapter 3 Operation PRM No. Cn-15 Brake command speed Factory setting 100 r/min Setting range 0 to 4,500 Cn-16 Brake timing 2 50 10 ms 10 to 100 Cn-17 Torque command filter time constant 4 100 µs 0 to 250 Cn-18 Forward rotation external current limit 100 % 0 to 350 Cn-19 Reverse rotation external current limit 100 % 0 to 350 Cn-1A Position loop gain 40 1/s 1 to 1,000 Cn-1b Positioning completion range Bias rotational speed Feed-forward amount 3 Commands r/min % 0 to 250 Deviation counter over level No. 1 internal speed setting No. 2 internal speed setting No. 3 internal speed setting Speed conformity signal output width 1,024 Cn-1C Cn-1d Cn-1E Cn-1F Cn-20 Cn-21 Cn-22 Cn-23 Cn-24 Cn-25 Cn-26 Cn-27 Cn-28 Cn-29 Cn-2A Cn-2b Parameter name 0 0 Unit 0 to 450 0 to 100 Explanation Sets rotation speed for outputting brake commands. Waiting time from servo-off to brake command output. Setting for torque command filter time constant (6.4 to 398 Hz). Output torque for when forward rotation current limit is input (compared to rated torque). Output torque for when reverse rotation current limit is input (compared to rated torque). Adjusts the position loop response. Positioning completion signal output range setting Position control bias setting Position control feed-forward compensation value Setting for detection of deviation counter overrun Rotation speed, no. 1 internal setting Rotation speed, no. 2 internal setting Rotation speed, no. 3 internal setting Sets the allowable fluctuation width for the speed conformity signal. Sets the deceleration time for software starts. Setting range: 0 0 xG /G x 100 00 0.01 G1/G2 100 x256 1 to 32,767 command r/min 0 to 4,500 200 r/min 0 to 4,500 300 r/min 0 to 4,500 10 r/min 0 to 100 Soft start deceleration time (Note 4) Electronic gear ratio G1 (numerator) (Note 2) Electronic gear ratio G2 (denominator) (Note 2) Position command acceleration/deceleration constant Feed-forward command filter Compensation gain 0 ms 0 to 10,000 4 --- 0 to 65,535 1 --- 0 to 65,535 0 0.1 ms 0 to 640 Sets the pulse smoothing constant 0 0.1 ms 0 to 640 0 --- 0 to 100 Position lock rotation speed Motor selection (Note 2) Control mode selection (Note 2) 10 r/min 0 to 4,500 (Table 1) 1 ----- 0 to 255 0 to 11 Feed-forward command filter setting Positioning time adjustment gain Sets the position lock rotation speed. Sets the applicable motor. Sets the control mode. (Table 2) 3-17 Chapter 3 Operation PRM No. Cn-2C Cn-2d Parameter name Encoder power supply voltage (Note 7) Output signal selection Factory setting 52,500 Unit 0.1 mV 210 --- Setting range 52,000 to 58,000 110 to 666 Explanation Changes the encoder power supply voltage. Selects control output functions. (Table 3) Note 1. Cn-04 (speed loop gain) is factory set for three times the load inertia. Therefore, if the load inertia is extremely small, some oscillation may occur. If it does, then lower Cn-04 to 20 or less. Note 2. After the settings for Cn-0A (encoder divider rate), Cn-11 (number of encoder pulses), Cn-24 (electronic gear ratio G1), Cn-25 (electronic gear ratio G2), Cn-2A (motor selection), and Cn-2b (control mode selection) have been made, they become effective when the power is turned on again after having been cut off. (Check to see that the LED display has gone off.) Note 3. Set all values within the specified ranges. Note 4. Be sure to set both Cn-07 and Cn-23 when the software start function is used. Note 5. The setting for Cn-11 (number of encoder pulses) is determined by the encoder that is used. If any settings other than the following are used, the motor may not operate properly. [Incremental]: Cn-11 set value = 4,096 [Absolute]: Cn-11 set value = 8,192 Note 6. The upper limit for Cn-0A (encoder divider rate) is as follows: [Incremental]: Cn-0A upper limit = 4,096 [Absolute]: Cn-0A upper limit = 8,192 ! Caution The Cn-2C (encoder power supply voltage) setting depends on the encoder cable length. The encoder may be damaged if the setting is wrong. Refer to the following table when making the setting. Encoder [Incremental] [Absolute] 3m 5m 52,500 52,500 10 m 15 m 54,000 55,000 20 m 55,500 57,000 D Table 1: Cn-2A (Motor Selection) ! Caution Check to be sure that these settings are made correctly. If they are set incorrectly, the motor may malfunction or suffer damage. Driver model R88D-UT24H R88D-UT40H R88D-UT60H R88D-UT80H R88D-UT110H R88D-UT120H 3-18 Applicable motor model R88M-U1K030H-j/T-j R88M-U1K530H-j/T-j R88M-U2K030H-j/T-j R88M-U3K030H-j/T-j R88M-U4K030H-j/T-j R88M-U5K030H-j/T-j Set value 163 164 165 166 167 168 Chapter 3 Operation Driver model R88D-UT24V-j R88D-UT40V-j R88D-UT60V-j R88D-UT80V-j R88D-UT110V Applicable motor model R88M-U1K030V-jS1/X-jS1 R88M-U1K530V-jS1/X-jS1 R88M-U2K030V-jS1/X-jS1 R88M-U3K030V-jS1/X-jS1 R88M-U4K030V-jS1/X-jS1 R88M-U5K030V-jS1/X-jS1 Set value 163 164 165 166 167 168 Note The default setting of the R88D-UT110V is 4 kW (motor selection: “167”). When using a 5-kW motor, change the motor selection setting to “168.” D Table 2: Cn-2b (Control Mode Selection) ! Caution Check to be sure that these settings are made correctly. If they are set incorrectly, the motor may malfunction. Control mode Speed control (Analog commands) Position control (Pulse train commands) Torque control (Analog commands) Internally-set speed control Internally-set speed control Internally-set speed control Internally-set speed control Position control (Pulse train commands) Position control (Pulse train commands) Speed control (Analog commands) Speed control (Analog commands) Position control (Pulse train commands) [Factory setting] ←→ ←→ ←→ ←→ ←→ ←→ ←→ ←→ Speed control (Analog commands) Position control (Pulse train commands) Torque control (Analog commands) Speed control (Analog commands) Torque control (Analog commands) Torque control (Analog commands) Position lock prohibit Pulse prohibit Set value 0 1 2 3 4 5 6 7 8 9 10 11 D Table 3: Cn-2d (Output Signal Selection) Any of the functions can be allocated to the three output terminals. The three digits of the set value correspond respectively to the output terminals. The setting “0” can be made only for the first digit (CN1-25, 26 pins). Example Setting 210 Function for CN1-25, 26 pins Function for CN1-27, 28 pins Function for CN1-29, 30 pins Output signal function In position (INP) / Speed compare (VCMP) Motor rotation detection (TGON) Servo ready (READY) Current limit detection (CLIMT) Brake interlock (BKIR) Overload warning (OLWRN) Overload alarm (OLALM) Set value 0 1 2 3 4 5 6 3-19 Chapter 3 Operation 3-3-3 Important User Parameters This section explains the checks and settings that are required before using the Servomotor and Servo Driver. These parameters must be set correctly. If they are set incorrectly, the motor may fail to operate or may malfunction. Make the appropriate settings for the system that is being used. H Control Mode Settings The control mode is set by user parameter Cn-2b. Cn-2b set value Independent control modes Internally-set speed control modes Control modes Switching control modes Control modes with added functions Speed control 0 Position control 1 Torque control 2 Internally-set speed control 3 Internally-set speed control + speed control 4 Internally-set speed control + position control 5 Internally-set speed control + torque control 6 Position control + speed control 7 Position control + torque control 8 Speed control + torque control 9 Speed control with position lock function 10 Position control (Pulse prohibit/enable) 11 H Number of Encoder Pulses (Cn-11) The number of pulses varies depending on the type of encoder that is connected. Match the settings to the encoder type. The factory settings are for an incremental encoder. Change the settings for these parameters if an absolute encoder is to be used. If the settings are not made correctly, the motor may malfunction. PRM No. Parameter name Cn-11 Number of encoder pulses l 3-20 Factory setting 4,096 , Unit Pulses/revolution Set value 4,096 8,192 Encoder type [Incremental] [Absolute] Chapter 3 Operation 3-3-4 Setting Internal Speed Control H Function • This function controls Servomotor speed using the speeds set in the parameters (No. 1, No. 2, and No. 3 internal speed settings). • This function can be used in the speed control modes. (It can’t be used with torque control.) Select the internal speed using the control inputs CN1-45 and 46 (speed selection commands 1 and 2) and specify the rotational direction using the CN1-41 (rotation direction command). • When both speed selection commands 1 and 2 are OFF, the motor will decelerate to a stop in the software start deceleration time and then go into servo lock status. Depending on the parameter settings, it is possible to use pulse train inputs (for position control), speed command inputs (for speed control), and torque command inputs (for torque control) in this status. H User Parameter Settings • Set user parameter Cn-02 (control mode selection) to any number from “3” to “6.” When this bit is set to “1,” the internal speed control settings function can be used and CN1-45, 46, and 41 have the following functions: Control inputs CN1-45 and 46: . . . . Control input CN1-41: . . . . . . . . . . . Speed selection commands 1 and 2 (SPD1 and SPD2) Rotation direction command (RDIR) • The following table shows the combinations of speeds and directions that can be selected with these three control inputs. CN1-45 CN1-46 CN1-41 Internal speed setting, rotational direction SPD1 SPD2 RDIR OFF ON OFF No. 1 internal speed setting, forward ON No. 1 internal speed setting, reverse ON ON OFF No. 2 internal speed setting, forward ON No. 2 internal speed setting, reverse ON OFF OFF No. 3 internal speed setting, forward ON No. 3 internal speed setting, reverse D Internal Speed Control Settings Only: Control Mode Selection (Cn-2b = “3”) • Setting user parameter Cn-2b (control mode selection) to “3” specifies the “internal speed control settings only” mode. • When both SPD1 and SPD2 are OFF, the motor will decelerate to a stop and then go into servo lock status with an internal speed command status of 0 r/min. (Position lock will not be in effect.) • Speed command inputs, pulse train inputs, and torque command inputs cannot be received. D Internal Speed Control Settings + Speed Control: Control Mode Selection (Cn-2b = “4”) • Setting user parameter Cn-2b (control mode selection) to “4” specifies the “internal speed control settings + speed control” mode. • Speed control using internal speed settings and speed command inputs (REF) is possible in this control mode. • Speed command inputs (REF) can be received from the point at which both SPD1 and SPD2 turn OFF. 3-21 Chapter 3 Operation D Internal Speed Control Settings + Position Control: Control Mode Selection (Cn-2b = “5”) • Setting user parameter Cn-2b (control mode selection) to “5” specifies the “internal speed control settings + position control” mode. • Speed control using internal speed settings and position control using pulse train inputs are possible in this control mode. • When both SPD1 and SPD2 are OFF, the motor will decelerate to a stop. When the positioning completion signal is output, the position lock is in effect and the system is ready to receive the pulse command input. • Pulse commands can be input after the positioning completion (INP) signal turns ON. Pulses input up until that point will be ignored. Likewise, when switching from position control to internally-set speeds, wait until the positioning completion (INP) signal turns ON before turning ON the speed selection command. If the speed selection command is turned ON during command pulse input, command pulse transmission and positioning will be ended before switching to internally-set speeds. D Internal Speed Control Settings + Torque Control: Control Mode Selection (Cn-2b = “6”) • Setting user parameter Cn-2b (control mode selection) to “6” specifies the “internal speed control settings + torque control” mode. • Speed control using internal speed settings and torque control using torque command inputs (TREF) are possible in this control mode. • Torque command inputs (TREF) can be received from the point at which both SPD1 and SPD2 turn OFF. H Other User Parameter Settings PRM No. Cn-07 Parameter name Soft start acceleration time Factory Unit setting 0 ms Setting range 0 to 10,000 Cn-23 Soft start deceleration time 0 ms 0 to 10,000 Cn-26 0 0.1 ms 0 to 640 Cn-14 Position command acceleration/deceleration constant Speed control 3,000 r/min 0 to 4,500 Cn-1F No. 1 internal speed setting 100 r/min 0 to 4,500 Cn-20 No. 2 internal speed setting 200 r/min 0 to 4,500 Cn-21 No. 3 internal speed setting 300 r/min 0 to 4,500 Explanation Sets the time for the motor to accelerate from 0 r/min to 4,500 r/min. Sets the time for the motor to decelerate from 4,500 r/min to 0 r/min. Sets the constant for pulse smoothing. Sets the speed limit for the torque control mode. Sets the speed for when SPD1 is OFF and SPD2 is ON. Sets the speed for when SPD1 is ON and SPD2 is ON. Sets the speed for when SPD1 is ON and SPD2 is OFF. Note 1. The software start acceleration and deceleration times are effective on the internal speed settings and the speed command input (REF). 3-22 Chapter 3 Operation Note 2. Acceleration and deceleration times are set at up to 4,500 r/min. The actual acceleration and deceleration times are found by means of the following formula: Actual acceleration (deceleration) time = Internally set speed (r/min) 4,500 (r/min) × Soft start acceleration (deceleration) time Motor speed 4,500 r/min Speed Note 3. The position command acceleration/deceleration constant is effective on pulse commands. Note 4. The speed limit setting is effective only in torque control mode. H Operation Examples D Internal Speed Control Settings Only (Cn-2b = “3”) Speed selection command 1 SPD1 Speed selection command 2 SPD2 Rotation direction command RDIR Speed 3 Speed 2 Speed 1 Motor operation Speed 1 Note There is a maximum delay of 6 ms in reading the input signal. 3-23 Chapter 3 Operation D Internal Speed Control Settings + Speed Control (Cn-2b = “4”) Speed selection command 1 SPD1 Speed selection command 2 SPD2 Rotation direction command RDIR Speed command input REF Speed 3 Speed 2 Motor operation Speed 1 REF speed Speed control mode Speed control mode Speed 1 Note When the control mode is “internal speed control settings + speed control,” operation follows the speed command input (REF) immediately after SPD1 and SPD2 are both OFF (although there is a delay of up to 6 ms in reading the input signal). There is no need to wait until the servo-lock operates. D Internal Speed Control Settings + Position Control (Cn-2b = “5”) Speed selection command 1 SPD1 6 ms min. Speed selection command 2 SPD2 Rotation direction command RDIR 6 ms min. Pulse command Positioning completion, INP (Speed compare, VCMP) Motor operation Speed 3 Speed 2 Speed 1 Speed 1 Note 1. There is a maximum delay of 6 ms in reading the input signal. 3-24 Chapter 3 Operation Note 2. The shaded areas in the time chart for the positioning completion signal indicate the places where the signal is turned ON as the speed compare (VCMP) signal. (The meaning of the signal differs according to the control mode.) D Internal Speed Control Settings + Torque Control (Cn-2b = “6”) Speed selection command 1 SPD1 Speed selection command 2 SPD2 Rotation direction command RDIR Torque command input TREF Speed 3 Speed 2 Motor operation Speed 1 Torque control mode Speed 1 Note 1. When the control mode is “internal speed control settings + torque control,” operation follows the torque command input (TREF) immediately after SPD1 and SPD2 are both OFF (although there is a delay of up to 6 ms in reading the input signal). Note 2. Motor operation with torque control varies according to the motor load conditions (e.g., friction, external power, inertia). Note 3. When motor servo-lock is required, set any of the internal speed settings to “0 r/min” and select that speed with speed selection commands 1 and 2. 3-3-5 Switching Control Mode H Function This function controls the motor by switching between two control modes by means of external inputs. The control mode switching is executed at control input terminal CN1-41 (control mode switching). H User Parameter Settings Set “7,” “8,” or “9” for user parameter Cn-2b (control mode selection). This setting causes control input terminal CN1-41 to become a control mode switching terminal (TVSEL). The following tables show the control modes. Control mode Position control (Pulse train command) ←→ Speed control (Analog command) Position control (Pulse train command) ←→ Torque control (Analog command) Speed control (Analog command) ←→ Speed control (Analog command) Set value 7 8 9 3-25 Chapter 3 Operation Set value 7 8 9 Selected Control Mode CN1-41: OFF Position control Position control Torque control CN1-41: ON Speed control Torque control Speed control H Operation D Position and Speed Control Switching Example (Cn-2b = “7”) 6 ms min. Control mode switching TVSEL Speed command input REF 6 ms min. Pulse commands Positioning completion, INP (Speed compare, VCMP) Motor operation Note 1. There is a maximum delay of 6 ms in reading the input signal. Note 2. When switching from speed control to position control, input the pulse command after the control mode switching (TVSEL) has turned OFF, the positioning completion (INP) signal has turned ON, and 6 ms has elapsed. The pulses will be ignored until the positioning completion (INP) signal has turned ON. Note 3. The shaded areas in the time chart for the positioning completion signal indicate the places where the signal is turned ON as the speed compare (VCMP) signal. (The meaning of the signal differs according to the control mode.) 3-26 Chapter 3 Operation D Position and Torque Control Switching Example (Cn-2b = “8”) Control mode switching TVSEL 6 ms min. Torque command input TREF 6 ms min. (Forward operation) (Reverse operation) Pulse commands Positioning completion signal INP Motor operation Impact Note 1. This time chart shows an example of torque thrust. Note 2. There is a maximum delay of 6 ms in reading the input signal. Note 3. When switching from torque control to position control, input the pulse command after the control mode switching (TVSEL) has turned OFF, the positioning completion (INP) signal has turned ON, and 6 ms has elapsed. The pulses will be ignored until the positioning completion (INP) signal has turned ON. D Speed and Torque Control Switching Example (Cn-2b = “9”) Control mode switching TVSEL Speed command input REF Torque command input TREF Motor operation Torque control mode Note 1. There is a maximum delay of 6 ms in reading the input signal. 3-27 Chapter 3 Operation Note 2. Motor operation with torque control varies according to the motor load conditions (e.g., friction, external power, inertia). 3-3-6 Software Start Function H Function • This function starts and stops the Servomotor according to the acceleration and deceleration times that have been set. • The acceleration curve is trapezoidal. Acceleration and deceleration can be set independently. • Use software start processing for speed command inputs (or internal speed settings) to minimize impact at the time of acceleration and deceleration. • This function is effective for simple positioning and when changing speeds. • Set the parameters as shown in the following table. PRM No. Cn-07 Parameter name Soft start acceleration time Factory Unit setting 0 ms Setting range 0 to 10,000 Cn-23 Soft start deceleration time 0 ms 0 to 10,000 Cn-29 Position lock rotation speed 10 r/min 0 to 4,500 Cn-1A Position loop gain 40 1/s 1 to 500 Explanation Sets the time for the motor to accelerate from 0 r/min to 4,500 r/min. Sets the time for the motor to decelerate from 4,500 r/min to 0 r/min. Setting for the rotation speed to cause position lock. Adjusts position loop response. Note 1. The software start acceleration and deceleration times are effective on the internal speed settings and the speed command input (REF). This has no effect on the pulse command. Note 2. The position lock rotation speed setting is valid only for speed control. Note 3. The position loop gain adjusts the servo-lock force during position-lock. Note 4. Acceleration and deceleration times are set at up to 4,500 r/min. The actual acceleration and deceleration times are found by means of the following formula: Actual acceleration (deceleration) time = Internally set speed (r/min) 4,500 (r/min) × Soft start acceleration (deceleration) time Maximum rotation speed (4,500 r/min) 0 t Cn-07 3-28 Cn-23 Chapter 3 Operation H Timing Chart Speed command input REF Position lock command signal PLOCK Motor operation Cn-29 Cn-29 Servo-lock condition Note 1. Select “speed control with position lock” as the control mode (i.e., set “10” for Cn-2b) when controlling the position lock with an external signal. (Refer to 3-3-3 Important User Parameters for details.) Note 2. The Unit will go into servo-lock if the position lock signal (PLOCK) is ON and the number of motor rotations falls below the position lock rotations set in Cn-29. The motor will revolve when the internal speed command exceeds the position lock rotations. 3-3-7 Electronic Gear Function (Position Control) H Function With this function, the motor will revolve for the number of pulses derived by applying the electronic gear ratio to command pulses. The function is effective in the following types of situations: S Fine adjustments of positions and speeds when synchronizing two lines. S When using a positioner with a low command pulse frequency. S When setting a value such as 0.01 mm for the amount of mechanical movement per pulse. H User Parameter Settings [Incremental] • The gear ratio utilizes G1 and G2 for user parameters Cn-24 and Cn-25, and is defined by G1/G2. Target number of pulses = Number of command pulses x G1 G2 PRM No. Parameter name Cn-24 Electronic gear ratio G1 (numerator) Cn-25 Electronic gear ratio G2 (denominator) Factory setting 4 Unit ___ 1 ___ Setting range Explanation Setting range: 1 to 65,535 1 to 65,535 0.01 x G1/G2 x 100 Note The electronic gear setting becomes effective when the power is turned on again after having been cut off. (Check to see that the LED display has gone off.) 3-29 Chapter 3 Operation • When G1/G2 = 1, the motor makes one revolution with a 16,384-pulse command. (The driver operates with an internal multiplication factor of 4. • With the factory setting, the motor makes one revolution when 4,096 pulses are input. • A single pulse for position deviation (deviation counter) display or positioning completion range becomes a single input pulse. H Operation Example [Incremental] In this example, G1/G2 is set to16,384/1,000, and operation is the same as for a Servomotor of 1,000 (pulses/revolution). Servomotor Servo Driver 1,000 pulses Electronic gear 16,384 pulses 1 revolution (16,384 pulses) 3-3-8 Encoder Dividing Function [Incremental] H Function • With this function, any number of pulses can be set for encoder signals output from the Servo Driver. • The number of pulses per Servomotor revolution can be set within a range of 16 to 4,096. • Use this function for the following applications: When connecting to a positioner with a low response frequency. When it is desirable to set a pulse rate that is easily understandable. (For example, in a mechanical system in which a single Servomotor revolution corresponds to a movement of 10 mm, if the resolution is 5 µm/pulse, set the encoder dividing rate to 2,000 (pulses/ revolution). • Set the parameters as shown in the following table. PRM No. Cn-0A Parameter name Encoder divider rate Cn-11 Number of encoder pulses Factory setting 1,000 pulses/ revolution 4,096 pulses/ revolution Setting range Explanation 16 to 4,096 pulses/revolution Setting for number of output pulses from Servo Driver. 4,096 pulses/ revolution (Do not change the setting.) Note Theses parameters become effective when the power is turned on again after having been cut off. (Check to see that the LED display has gone off.) 3-30 Chapter 3 Operation H Operation • Incremental pulses are output from the Servo Driver through a frequency divider. Servo Driver Encoder A B E A-phase Frequency divider S B-phase Processing circuitry Z-phase • The output phases of the encoder signal output from the Servo Driver are as shown below (when divider rate Cn-0A = 4,096). Reverse Rotation Side Forward Rotation Side A-phase A-phase B-phase B-phase Z-phase Z-phase Note When the encoder divider rate is set to other than 4,096, 2,048, 1,024,..., the phase difference for phases A and B is not 90°, but scatters for time T. (See the diagram below.) A-phase B-phase t1 t2 t1 t1 t1 t1 t2 t1 = nT, t2 = (n+1)T In this diagram, T represents the time between phase A and phase B, and n is an integer that satisfies the following formula (with digits below the decimal point discarded). n = 4,096/encoder divider rate Input to frequency divider A-phase (encoder output) B-phase T 3-3-9 Encoder Dividing Function (Absolute) H Function • With this function, any number of pulses can be set for encoder signals output from the Servo Driver. • The number of pulses per Servomotor revolution can be set within a range of 16 to 8,192. • Use this function for the following applications: When connecting to a positioner with a low response frequency. When it is desirable to set a pulse rate that is easily understandable. 3-31 Chapter 3 Operation (For example, in a mechanical system in which a single Servomotor revolution corresponds to a movement of 10 mm, if the resolution is 5 µm/pulse, set the encoder dividing rate to 2,000 (pulses/ revolution). • Set the parameters as shown in the following table. PRM No. Cn-0A Parameter name Encoder divider rate Cn-11 Number of encoder pulses Factory setting 1,000 pulses/ revolution 4,096 pulses/ revolution Setting range Explanation 16 to 8,192 pulses/revolution Setting for number of output pulses from Servo Driver. 8,192 pulses/ revolution (Be sure to change the setting to “8,192.”) Note Theses parameters become effective when the power is turned on again after having been cut off. (Check to see that the LED display has gone off.) H Operation • Incremental pulses are output from the Servo Driver through a frequency divider. Servo Driver Encoder A B E Frequency divider A-phase B-phase Z Z-phase • The output phases of the encoder signal output from the Servo Driver are as shown below (when divider rate Cn-0A = 8,192). Forward Rotation Side Reverse Rotation Side A-phase A-phase B-phase B-phase Z-phase Z-phase The Z-phase is synchronized with the A-phase, but its pulse width may become shorter than that of the A-phase. Note When the encoder divider rate is set to other than 8,192, 4,096, 2,048,..., the phase difference for phases A and B is not 90°, but scatters for time T. (See the diagram below.) A-phase B-phase t1 3-32 t2 t1 t1 t1 t1 t2 t1 = nT, t2 = (n+1)T Chapter 3 Operation In this diagram, T represents the time between phase A and phase B, and n is an integer that satisfies the following formula (with digits below the decimal point discarded). n = 8,192/encoder divider rate Input to frequency divider A-phase (encoder output) B-phase T 3-3-10 Bias Function (Position Control) H Function • The bias function shortens positioning time by adding bias revolutions to speed commands. • If the residual pulses in the deviation counter exceed the positioning completion range (Cn-1b), the bias rotational speed (Cn-1C) is added to the speed command until the pulses are within the positioning completion range. • Set the parameters as shown in the following table. PRM No. Cn-1b Parameter name Factory setting Positioning completion range 3 command units Cn-1C Bias rotational speed 0 r/min Setting range 1 to 250 command units 0 to 450 r/min Explanation Sets range for positioning completion signal output. Sets position control bias. Note 1. When not using the bias function, set the bias rotational speed to 0 r/min. Note 2. If the bias rotational speed is set too high, it will cause motor operation to be unstable. The optimum setting depends on the load, the gain, and the positioning completion range, so adjust the setting while observing the motor response. (Begin with a bias setting of “0,” and gradually increase it.) 3-33 Chapter 3 Operation H Operation Example • In this example, the bias rotational speed (Cn-1C) is added to the deviation counter output (speed command) when the residual pulses in the deviation counter exceed the positioning completion range (Cn-1b). This continues until the residual pulses in the deviation counter are within the positioning completion range, and then it stops. • For the internal processing block configuration, refer to the position loop block diagram in 3-5-2 Manually Adjusting Gain (Position Control). Speed command (command pulse frequency) Motor speed without bias function Motor speed with bias function Motor speed Time Shortened time Positioning completion signal INP 3-3-11 Torque Limit Function (Position Control, Speed Control, Torque Control) H Function • The torque limit function limits the Servomotor’s output torque; it can be used with position control, speed control, and torque control. • This function can be used to protect the Servomotor and machine system by preventing excessive force or torque on the machine system when the machine (moving part) pushes against the workpiece with a steady force, such as in a bending machine. • There are three methods that can be used to limit the torque: 1. Limit the steady force applied during normal operation with user parameters Cn-08 (forward torque limit) and Cn-09 (reverse torque limit). 2. Limit operation with external signals connected to pins CN1-45 (PCL: forward current limit input) and CN1-46 (NCL: reverse current limit input). Set user parameters Cn-18 (forward rotation external current limit) and Cn-19 (reverse rotation external current limit). 3. Limit operation with analog voltage by using TREF (torque command input) as the analog current limit input. 3-34 Chapter 3 Operation H Parameter Settings D Method 1: Limiting the Force Applied During Operation • User Parameter Settings PRM No. Unit Parameter name Cn-08 Forward torque limit Factory setting Maximum torque Setting range % of rated torque Cn-09 Reverse torque limit Maximum torque % of rated torque Explanation 0 to maximum This parameter sets the output torque torque limit for the forward direction (as a percentage of the rated torque). 0 to maximum This parameter sets the output torque torque limit for the reverse direction (as a percentage of the rated torque). Note 1. This method is effective with speed control, internal speed control settings, and torque control. Note 2. Set these parameters to the maximum torque (the factory setting) when the torque limit function isn’t being used. D Method 2: Limiting Operation with External Signals • Control Mode Selection (Cn-02 = 0 to 2, 7 to 11) Set the control mode selection (Cn-2b) to a control mode other than internally-set speed control (3 to 6). With this setting, control input terminal CN1-45 will be PCL (forward current limit input), CN1-46 will be NCL (reverse current limit input), and it will be possible to use the external current limit function. • User Parameter Settings PRM No. Parameter name Cn-18 Forward rotation external current limit Cn-19 Reverse rotation external current limit Factory setting 100 Unit % of rated torque to que Setting range Explanation 0 to maximum This parameter sets the limit torque to que when PCL is ON. This parameter sets the limit when NCL is ON. D Method 3: Limiting Operation with Analog Voltage • Setup Parameter Settings (Bit 8 of Cn-02 = 1) Set bit 8 of Cn-02 (the TREF switch) to “1.” When bit 8 is “1,” terminals CN1-9 and CN1-10 (TREF and AGND) become analog current limit input terminals. The current limit value can be calculated from the following equation: Current limit value = (absolute value of voltage applied to TREF) × (torque command scale) The polarity of the analog voltage is irrelevant and the same current limit value is used for forward and reverse. • User Parameter Settings PRM No. Units Parameter Factory name setting Cn-13 Torque com- 30 0.1 V/rated mand scale torque Setting range 10 to 100 Explanation This parameter sets the gain for the torque command input. Note 1. This method is useful when controlling torque in multiple stages. 3-35 Chapter 3 Operation Note 2. This method is effective with speed control and torque control. Note 3. This method can’t be used when the torque feed-forward function is being used (i.e., when bit 9 of Cn-02 is set to “1.”) 3-3-12 Speed Limit Function (Torque Control) H Function • This function limits motor rotation speed when torque control is used. It sets a limit so that the motor rotation speed does not exceed the maximum speed of the mechanical system. • Outside of the speed limit range, a torque in proportion to the difference with the speed limit value is generated to slow down the motor rotation speed. In such cases the number of motor rotations does not necessarily match the speed limit value. (The number of motor rotations varies depending the load.) • There are two methods that can be used for limiting the speed: 1. Apply a constant fixed speed limit for torque control, by means of user parameter Cn-14 (speed limit). 2. Limit the speed by means of analog voltage. Use REF (speed command input) as an analog speed limit input. H Parameter Settings D Applying a Constant Fixed Speed Limit for Torque Control • User Parameter Settings PRM No. Parameter name Cn-14 Speed limit Factory setting 3,000 Units Setting range Explanation r/min 0 to 4,500 This parameter sets the speed limit value for torque control. D Limiting the Speed with Analog Voltage • Set bit no. 2 of setup parameter Cn-02 to “1.” When bit no. 2 is “1,” terminals CN1-5 and CN1-6 (REF and AGND) become analog speed limit input terminals. The speed limit value can be calculated from the following equation: Speed limit value = (absolute value of voltage applied to REF) × (speed command scale) • If the voltage is positive, this becomes the speed limit value for both the forward and reverse directions. (If the voltage is negative, this is regarded as a limit value of 0 r/min. • User Parameter Settings PRM No. Parameter name Cn-03 Speed command scale 3-36 Factory setting 300 Units Setting range (r/min) ⁄ V 10 to 2,000 Explanation This parameter sets the number of rotations per speed command volt. Chapter 3 Operation 3-3-13 Torque Feed-forward Function (Speed Control) H Function • The torque feed-forward function reduces the acceleration time by adding the value of the torque command input (TREF) to the current loop; it can be used with speed control. • Normally a derivative value is generated in the Controller and this value is input to TREF. • Overshooting will occur if the feed-forward amount (the voltage input to TREF) is too high, so adjust user parameter Cn-13 (the torque command scale) as required. • The following figure shows a block diagram when the torque feed-forward function is used. Host Controller Position command AC Servo Driver Derivative Speed loop Encoder output Current loop Speed detection Divider H Parameter Settings • Setup Parameter Settings (Bit 9 of Cn-02 = 1) Set bit 9 of Cn-02 (the torque feed-forward switch) to “1.” When bit 9 is “1,” terminals CN-9 and CN-10 (TREF and AGND) become the torque feed-forward input terminals. • User Parameter Settings PRM No. Units Parameter Factory name setting Cn-13 Torque com- 30 0.1 V/rated mand scale torque Setting range 10 to 100 Explanation This parameter sets the gain for the torque command input. H Operation Speed command Torque feed-forward Motor output torque Number of motor revolutions Without the torque feed-forward function Without the torque feed-forward function 3-37 Chapter 3 Operation Note 1. If torque feed-forward is input when the motor’s rotational speed is fixed, the rotational speed won’t match the speed command. Design the Controller’s circuit so that torque feed-forward is applied only when the motor is accelerating or decelerating. Note 2. A torque will be generated that accelerates the motor in the forward direction if torque feedforward is applied with a positive (+) voltage. Be sure that the polarity is correct because errors such as reverse motor rotation or oscillation will occur if the feed-forward is applied with a polarity opposing the acceleration direction. 3-3-14 Brake Interlock (for Motors With Brakes) U-series AC Servo Drivers have a brake interlock signal (BKIR) to control the magnetic brake. In addition, they have a built-in dynamic brake circuit. H Magnetic Brakes The magnetic brakes for Servomotors with brakes are specialized holding brakes with non-magnetized operation. Therefore set the parameters so that the brake power supply is turned off after the Servomotor stops. If the brake is applied while the Servomotor is operating, the brake will suffer abnormal wear or even damage, and will quickly become defective. For wiring methods, refer to 2-2-4 Peripheral Device Connection Examples. D Parameters to be Set PRM No. Cn-12 Brake timing 1 Factory setting 0 10 ms Cn-15 Brake command speed 100 r/min Cn-16 Brake timing 2 50 10 ms 3-38 Parameter name Unit Setting range 0 to 50 Explanation Delay time setting from brake command until servo turns off. 0 to 4,500 Sets rotation speed for outputting brake commands. 10 to 100 Waiting time from servo-off to brake command output. Chapter 3 Operation D Timing for Run Command (RUN) <When Servomotor is Stopped> Power supply ON OFF Run command RUN ON OFF Brake interlock signal BKIR ON OFF Brake power supply ON OFF Approx. 6 ms 0 to 35 ms 200 ms max. Brake operation 100 ms max. Cancelled Maintained (See note 1) ON Speed command (or pulse command) OFF Cn-12 (See note 2.) Power on Power to motor Power off Note 1. It takes up to 200 ms for the brake to be cleared after the brake power supply has been turned on. Taking this delay into account, have the speed command (or pulse command) be given after the brake has been cleared. Note 2. It takes up to 100 ms for the brake to be held after the brake power supply has been turned off. When using it for the vertical shaft, take this delay into account and set brake timing 1 (Cn-12) so that the Servomotor will not receive power until after the brake is held. D Timing for Power Supply <When Servomotor is Stopped> Power supply ON OFF 25 to 35 ms Brake interlock signal BKIR ON OFF Cn-12 Power to motor (See note) Power on Power off Note It takes up to 100 ms for the brake to be held after the brake power supply has been turned off. When using it for the vertical shaft, take this delay into account and set brake timing 1 (Cn-12) so that the Servomotor will not receive power until after the brake is held. 3-39 Chapter 3 Operation D Timing for Run Command (RUN), Errors, Power Supply <When Servomotor is Stopped> Power supply ON OFF ON Run command RUN OFF Alarm output ALM OFF ON (See note 2.) Brake interlock signal BKIR Power to motor ON OFF Power on Power off Approx. 10 ms (See note 1.) Motor rotation speed Brake command speed (Cn-15) Braking by dynamic brake (When Cn-01 bit no. 6 = 0) Note 1. For the approximately 10 ms it takes from when the power to the Servomotor turns off until the dynamic brake operates, the Servomotor rotates by momentum. Note 2. If the Servomotor rotation speed falls below the speed set for the brake command speed (Cn-15), or if the time set for brake timing 2 (Cn-16) elapses after the Servomotor stops receiving power, the brake interlock signal (BKIR) will turn OFF. 3-40 Operation 3-4 Chapter 3 Trial Operation After the wiring is complete and the parameter settings have been made, conduct a trial operation. Follow he procedure outlined below, to be prepared for unlikely events such as motor runaway. H Preparation for Trial Operation • Do not connect a load (i.e., the mechanical system) to the Servomotor. • Cut off the run command (RUN) so that the Servomotor can be stopped at any time. H Actual Trial Operation (1) Powering Up • With the run command (RUN) OFF, apply an AC voltage. • After internal initialization, the mode will be the status display mode. • Set the speed loop gain (Cn-04) to 20 or less. (Match the gain with no load.) (2) Turning ON the Run command Input • Turn ON the run command input. The Servomotor will go into servo-ON status. (3) Low Speed Operation by the Servomotor Alone • Give a speed command, or carry out the following check with a jogging operation. Is the direction of Servomotor rotation correct? Are there any abnormal sounds or vibration? Is anything abnormal occurring? • If anything abnormal occurs, refer to Chapter 4 Application and apply the appropriate countermeasures. (4) Low Speed Operation With a Load Connected • After the low speed operation by the Servomotor alone is completed, connect a load (i.e., connect to the mechanical system). Make the connections securely, with no loose screws. • Operate at low speed, and check the following items. Is the emergency stop operating correctly? Are the limit switches operating correctly? Is the operating direction of the machinery correct? Are the operating sequences correct? Are there any abnormal sounds or vibration? Is anything abnormal occurring? • If anything abnormal occurs, refer to Chapter 4 Application and apply the appropriate countermeasures. (5) Operation Under Actual Load Conditions • After adjusting the gain (refer to Section 3-5), operate the Servomotor in a regular pattern and check the following items. Is the speed correct? (Use the speed display.) Is the load torque roughly equivalent to the measured value? (Use the torque command display.) Are the positioning points correct? When an operation is repeated, is there any discrepancy in positioning? Are there any abnormal sounds or vibration? Is either the Servomotor or the Servo Driver abnormally overheating? Is anything abnormal occurring? • If anything abnormal occurs, refer to Chapter 4 Application and apply the appropriate countermeasures. 3-41 Chapter 3 Operation H Jog Operations Jog operations rotate the Servomotor in a forward or reverse direction using the Parameter Unit. Jog operations are made possible when system check mode Cn-00 is set to “00.” The items in parentheses in the following explanation indicate operations using the Handy-type Parameter Unit. [1] c n Ć Indicates settings mode. 0 [2] 0 System check mode 0 DATA 0 Ć 0 [5] 0 Data OFF [4] [4] ON 0 g 1. Using the Up and Down (and Right and Left) Keys, set parameter number “00.” (System check mode) 2. Press the DATA Key to display the Cn-00 data. 3. Using the Up and Down (and Right and Left) Keys, set data “00.” (Jog operation) 4. Using the MODE/SET Key, turn ON and OFF the jog operation from the Parameter Unit. With the jog operation ON, operation by the Parameter Unit is enabled. For the run operation, refer to “Operation Method” below. 5. Press the DATA Key to return to the parameter number display. 6. Press the MODE/SET Key to move from settings mode to monitor mode. D Operation Method 1. With the DATA (SERVO) Key, turn the servo ON and OFF. 2. With the servo ON, press the Up Key to rotate the Servomotor forward. 3. With the servo ON, press the Down Key to rotate the Servomotor in reverse. D Parameters to be Set (User Parameter Cn-10) The rotational speed during jog operation can be set with user parameter Cn-10, as shown in the following table. PRM No. Cn-10 3-42 Parameter name Jog speed Factory setting 500 Unit r/min Setting range 0 to 4,500 Explanation Speed setting for jog operation Chapter 3 Operation 3-5 Making Adjustments 3-5-1 Auto-tuning Auto-tuning rotates the Servomotor with a load connected (mechanical system), and automatically adjusts the position loop gain, the speed loop gain, and the speed loop integration time constant. When adjustments cannot be made by auto-tuning, refer to 3-5-2 Manually Adjusting Gain. H Executing Auto-tuning Auto-tuning is made possible when the system check mode Cn-00 is set to “05.” The items in parentheses in the following explanation indicate operations using the Handy-type Parameter Unit. [1] c n Ć 0 [2] 0 DATA [3] 0 0 Ć 0 5 [6] Indicates settings mode. System check mode Data [4] [5] c Ć 0 0 1 Mechanical rigidity selection display t u n n d Auto-tuning display e Auto-tuning end display 1. Using the Up and Down (and Right and Left) Keys, set parameter number “00.” (System check mode) 2. Press the DATA Key to display the Cn-00 data. 3. Using the Up and Down (and Right and Left) Keys, set data “05.” (Auto-tuning) 4. Press the MODE/SET Key to display the mechanical rigidity selection. (Refer to Selecting Mechanical Rigidity below.) 5. Press the MODE/SET Key to change to the auto-tuning display. (Refer to the following “Auto-tuning Procedure.”) 6. Press the DATA Key to return to the parameter number display. 7. Press the MODE/SET Key to move from settings mode to monitor mode. 3-43 Chapter 3 Operation D Selecting Mechanical Rigidity Select the set value to match the rigidity of the mechanical system. Response Low Medium High g Set Position loop gain value (1/s) 001 16 002 28 003 40 004 005 006 007 56 78 108 130 Representative applications Articulated robots,, harmonic drives,, chain drives,, belt drives,, k and d pinion i i d i rack drives, etc. XY tables, Cartesian-coordinate robots, general-purpose machinery, etc. Ball screws ((direct coupling), g), feeders,, etc. Note The response will rise according to a rise in the rigidity of the mechanical system. D Auto-tuning Procedure 1. With the DATA (SERVO) Key, turn the servo ON and OFF. 2. While pressing the Up Key, operate the Servomotor three times in the forward direction and adjust the gain. The auto-tuning will not be complete until the Servomotor has been operated at least three times. If the auto-tuning is not complete after three times, then repeat the operation while holding down the Up Key. The Servomotor rotation speed should be approximately 1/2 that of the jog speed (Cn-10). 1/2 jog speed 0 Approx. 1.1 s Approx. 0.7 s 3. While pressing the Down Key, adjust the gain in the same way for the reverse direction. 4. By executing step 2 or step 3, the user parameter position loop gain (Cn-1A), speed loop gain (Cn-04), and speed loop integration time constant (Cn-05) will be adjusted automatically. These values will not be changed, however, until the auto-tuning operation has been completed. 5. When the auto-tuning operation is complete, “Ć. end” will be displayed at the Parameter Unit (while the Up and Down Keys are being pressed). When the Up and Down Keys are released, “00Ć05” will again be displayed. 6. If the auto-tuning operation is still not complete even after being executed many times, or if you wish to abort the operation, press the MODE/SET Key. After the MODE/SET Key is pressed, “00Ć05” will again be displayed. Note 1. If the auto-tuning operation is not completed, or if there is an inadequate response for the gain that is adjusted by auto-tuning, refer to 3-5-2 Manually Adjusting Gain and adjust the gain manually. Note 2. The auto-tuning will not be complete until the Servomotor has been operated at least three times, so pay sufficient attention to the operating range of the machinery. If auto-tuning cannot be executed within the operating range of the machinery, then adjust the gain manually. 3-44 Chapter 3 Operation 3-5-2 Manually Adjusting Gain There are eleven kinds of parameters for adjusting Servomotor response. For situations in which the factory settings or the settings derived from auto-tuning alone do not provide adequate characteristics, the settings can be adjusted manually. H Gain Adjustment Flowchart D For Position Control (Pulse Train Input) Adjustment procedures for position control are shown in the following flowchart. Perform auto-tuning to match the rigidity of the mechanical system. The motor hunts when servo-locked. (Accompanied by a hunting noise.) NO Raise the rigidity selection to the value just before hunting occurs and perform auto-tuning. Do characteristics such as positioning time meet system specifications? YES Decrease the rigidity selection so hunting doesn’t occur and perform auto-tuning. YES End adjustment. NO Increase Cn-04 (speed loop gain) to a value where hunting doesn’t occur in servo-lock. Decrease Cn-05 (speed loop integration time constant) to a value where hunting doesn’t occur in servo-lock. Does hunting (vibration) occur when the motor is operated? : NO Run the motor and monitor its operation. Increase Cn-1A (position loop gain) to a level where overshooting does not occur. End adjustment. YES Decrease Cn-04 (speed loop gain). Increase Cn-05 (speed loop integration time constant). : When vibration can’t be eliminated despite several adjustments, or when positioning is too slow: Increase Cn-17 (torque command filter time constant). Increase Cn-28 (compensating gain). 3-45 Chapter 3 Operation D For Speed Control (Analog Input) Adjustment procedures for speed control are shown in the following flowchart. Perform auto-tuning to match the rigidity of the mechanical system. The motor hunts when servo-locked. (Accompanied by a hunting noise.) NO Raise the rigidity selection to the value just before hunting occurs and perform auto-tuning. Do characteristics such as positioning time meet system specifications? YES Decrease the rigidity selection so hunting doesn’t occur and perform auto-tuning. YES End adjustment. NO Increase Cn-04 (speed loop gain) to a value where hunting doesn’t occur in servo-lock. Decrease Cn-05 (speed loop integration time constant) to a value where hunting doesn’t occur in servo-lock. Does hunting (vibration) occur when the motor is operated? : NO Run the motor and monitor its operation. When using position control: Reduce Cn-03 (speed command scale) or the Controller’s position loop gain to a level where overshooting doesn’t occur. When using speed control: Set Cn-03 (speed command scale) to match the desired number of revolutions. YES Decrease Cn-04 (speed loop gain). Increase Cn-05 (speed loop integration time constant). : When vibration can’t be eliminated despite several adjustments, or when positioning is too slow: Increase Cn-17 (torque command filter time constant). Increase Cn-28 (compensating gain). End adjustment. 3-46 Chapter 3 Operation H Adjustment Parameters The user parameters for making adjustments are shown in the following table. The symbols following each parameter name indicate which control modes that particular parameter can be used for. (P: Position control; S: Speed control; T: Torque control) PRM No. Parameter name Cn-04 Speed loop gain (P, S) Cn-05 Factory setting 80 Unit Setting range Explanation Hz 1 to 2,000 Adjusts the speed loop response. As this is made higher, the servo rigidity is strengthened. The greater the inertia rate, the higher this is set. If it is set too high, oscillation will occur. (See the illustration following this table.) Speed loop integra- 2,000 tion time constant (P, S) 0.01 ms 200 to 51,200 Speed loop integration time constant. As this is made longer, the response is shortened and the resiliency toward external force is weakened. If it is set too short, vibration will occur. (See the illustration following this table.) Cn-17 Torque command filter time constant (P, S, T) 4 0.1 ms 0 to 250 Sets torque command filter time constant. Make this large in order to reduce oscillation and vibration due to machinery resonance frequency. The filter characteristics are switched by the torque command filter degree (bit no. C of Cn-02). Cn-1A Position loop gain (P, S) 40 l/s 1 to 1,000 For speed control, this function is valid only when position-lock function is used. For position lock, use it for servo-lock adjustment. Servo system responsiveness is determined by position loop gain. When position loop gain is high, responsiveness increases and positioning can be speeded up. In order to increase position loop gain, it is necessary to increase mechanical rigidity and thereby increase the natural frequency (oscillation). In general, the setting range is 50 to 70 (l/s) for construction machinery, 30 to 50 (l/s) for general-purpose and assembly equipment, and 10 to 30 (l/s) for industrial robots. The factory setting is 40 (l/s), so it should be reduced for systems with low mechanical rigidity. If position loop gain is increased for a system with low mechanical rigidity, or with low natural frequency, resonance will occur and an overload alarm will be generated. If position loop gain is low, positioning time can be shortened by using feed-forward or the bias function. (For more detail, see the illustration following this table.) 3-47 Chapter 3 Operation PRM No. Cn-1b Parameter name Factory setting Positioning comple- 3 tion range (P) Unit Command Setting range 0 to 250 Cn-1C Bias rotational speed (P) 0 r/min 0 to 450 Cn-1d Feed-forward (P) 0 % 0 to 100 Explanation Sets the positioning completion range with input command pulses. (The settings are ordinarily based on the precision required by the machine.) positioning completion outputs smaller than required are slower. Caution: If this setting is too high, when there are few residual pulses the positioning completion output may turn ON while the motor is still rotating at low speed. Used to shorten positioning time. The higher this parameter is set, the more the positioning time is shortened. If it is set too high, however, operation will be unstable. Gradually increase the setting from 0 r/min while observing the response. Effective when position loop gain is small, i.e., less then 25 (1/s), but ineffective when it is large. Setting this parameter too high will increase overshooting. The feed-forward amount is added directly to the speed loop, bypassing the deviation counter and thereby speeding up the response (when load system is not slowed by command). Before adjusting the feed-forward amount, check to be sure that the position loop has been completely adjusted and that the speed loop is operating with stability. Cn-1E Deviation counter overrun level (P) 1,024 x 256 command units 1 to 32,767 Cn-26 Position command acceleration/deceleration constant (P) 0 0.1 ms 0 to 640 3-48 Start from 0% and increase the setting gradually. If the feed-forward amount is set too high, speed commands become like sawtooth waves and abnormal noises occur. Be careful when setting this parameter so that the positioning completion signal doesn’t repeat the ON/OFF cycle and speed overshooting doesn’t occur. The residual pulses in the deviation counter are equivalent to the command pulse frequency divided by the position loop gain. Divide this value by 256 to set a further allowance. Sets the pulse smoothing time constant. The motor accelerates and decelerates according to this setting even when position command pulses are input in steps. This is the position command software start function. The acceleration time is the same as the deceleration time. Set this parameter to 0 ms when using a positioner with an acceleration/deceleration function. Chapter 3 Operation PRM No. Cn-27 Cn-28 Parameter name Factory setting 0 Feed-forward command filter (P) Compensating gain 0 (P, S) Unit 0.1 ms Setting range 0 to 640 --- 0 to 100 Explanation Sets the filter so that the feed-forward amount is not added suddenly when position command pulses are input in steps. Decreases the speed loop gain by the set value when a large torque is output due to acceleration, deceleration, etc. Increasing the set value reduces motor oscillation, and positioning time can be shortened. If the set value is too large, a follow-up delay will occur for acceleration and deceleration. D Adjusting Speed Loop Gain (Cn-04) When the speed loop gain is manipulated, the response is as shown in the diagram below. Overshoots when speed loop gain is high. (Oscillates when gain is too high.) Motor speed (speed monitor) When speed loop gain is low. Time 3-49 Chapter 3 Operation D Adjusting the Speed Loop Integration Time Constant (Cn-05) When the speed loop integration time constant is manipulated, the response is as shown in the diagram below. Overshoots when speed loop integral time constant is short. Motor speed (speed monitor) When speed loop integral time constant is long. Time D Position Loop Gain (Cn-1A) Position loop gain is generally expressed as follows: Position loop gain (Kp) = Command pulse frequency (pulses/s) Deviation counter residual pulses (pulses) (1/s) When the position loop gain is manipulated, the response is as shown in the diagram below. When position loop gain is high Motor speed (speed monitor) When position loop gain is low Time 3-50 Chapter 3 Operation H Position Loop Block Diagram (Reference) Cn-1d Cn-24,25 Feedforward amount Electronic gear ratio G1/G2 Cn-27 Cn-1C Feed-forward command filter Bias rotational speed Cn-1b Cn-02: Bits 5, 4, and 3 Command pulses Cn-26 Command pulse mode Position command Acceleration/ deceleration time constant Positioning completion range Cn-24,25 Electronic gear ratio G1/G2 + – Deviation counter Cn-1E Cn-1A Position loop gain + – + + Cn-0A Encoder output Encoder divider rate ×4 Cn-04,05 Speed loop Cn-17 Current loop Cn-28 Comp. gain Speed detection ×4 E Encoder M Motor 3-51 Chapter 3 Operation 3-5-3 Adjusting Command Offset Use the following procedure to adjust the analog voltage offsets for the speed command and torque command. Command offset can be adjusted either automatically or manually. The torque command’s offset can’t be adjusted manually, so adjust it automatically. H Adjusting Instruction Offset Automatically Automatic adjustment of command offset is made possible when the system check mode Cn-00 is set to “01.” The items in parentheses in the following explanation indicate operations using the Handy-type Parameter Unit. [1] c n Ć 0 [2] 0 DATA [3] 0 0 Ć 0 1 [6] Indicates settings mode. System check mode Data [5] Instruction offset automatic adjustment executed. 1. Using the Up and Down (and Right and Left) Keys, set parameter number “00.” (System check mode) 2. Press the DATA Key to display the Cn-00 data. 3. Using the Up and Down (and Right and Left) Keys, set data “01.” (Instruction offset automatic adjustment) 4. Input the voltage required to set the speed command input (REF) and the torque command input (TREF) to zero rotation speed and zero output torque respectively. (Normally 0 V.) 5. Press the MODE/SET Key to automatically adjust the command offset. 6. Press the DATA Key to return to the parameter number display. 7. Press the MODE/SET Key to move from settings mode to monitor mode. 3-52 Chapter 3 Operation H Adjusting Instruction Offset Manually Manual adjustment of command offset is made possible when the system check mode Cn-00 is set to “03.” The items in parentheses in the following explanation indicate operations using the Handy-type Parameter Unit. [1] c n Ć 0 [3] [2] 0 DATA 0 0 Ć 0 3 [5] Indicates settings mode. System check mode Data [4] Offset data a Ć 0 0 2 Speed command input offset adjustment display [5] b Ć 0 0 5 Torque command input offset adjustment display 1. Using the Up and Down (and Right and Left) Keys, set parameter number “00.” (System check mode) 2. Press the DATA Key to display the Cn-00 data. 3. Using the Up and Down (and Right and Left) Keys, set data “03.” (Instruction offset manual adjustment) 4. Press the MODE/SET Key to change to the manual adjustment display. Refer to “Instruction Offset Manual Adjustment Method” below. 5. Press the DATA Key to return to the parameter number display. 6. Press the MODE/SET Key to move from settings mode to monitor mode. D Instruction Offset Manual Adjustment Method Input the voltage required to set the speed command input (REF) to zero rotation speed. (Normally 0 V.) 1. While the Up Key is being pressed, an offset is added in the forward direction. 2. While the Down Key is being pressed, an offset is added in the reverse direction. 3. Press the MODE/SET Key to save the offset data to memory and return to the data display. Note When the offset data display indicates zero, it is not necessarily the optimal adjustment. For speed control, make the offset adjustment determination based on Servomotor movement; for position control, make the determination based on the amount of accumulated pulses in the deviation counter. 3-53 Chapter 3 Operation 3-6 Regenerative Energy Absorption 3-6-1 Calculating Regenerative Energy Regenerative energy produced at times such as Servomotor deceleration is absorbed by the Servo Driver’s internal capacitors, thereby preventing an increase in DC voltage. If the regenerative energy from the Servomotor becomes too large, however, an overvoltage error will occur. In such cases, it is necessary to reduce the regenerative energy by taking an action such as changing operation patterns. Regenerative energy is produced when the direction of Servomotor rotation or output torque is reversed. The methods for calculating regenerative energy for the horizontal and vertical shafts are explained below. H Horizontal Axle +N1 Motor operation –N2 ÉÉ ÉÉ ÉÉ TD2 ÉÉÉÉ ÉÉÉÉ ÉÉÉÉ Eg2 TD1 Motor output torque Eg1 t1 t2 T Note In the output torque graph, acceleration in the positive side (rising) is shown as positive, and acceleration in the negative side (falling) is shown as negative. The regenerative energy for each section can be found by means of the following formulas: Eg1 = 1/2 S N1 S TD1 S t1 S 1.027 × 10–2 [J] Eg2 = 1/2 S N2 S TD2 S t2 S 1.027 × 10–2 [J] N1, N2: TD1, TD2: t1, t2: Rotation speed at beginning of deceleration [r/min] Deceleration torque [kgf S cm] Deceleration time [s] Note There is some loss due to winding resistance, so the actual regenerative energy will be approximately 90% of the figure derived by the formula. 3-54 Chapter 3 Operation To find the regenerative processing capacity, it is necessary to calculate the average regenerative power. 1. Energy (Eg) consumed by regenerative resistance: The regenerative energy that cannot be absorbed by the Servo Driver’s internal capacitors is consumed by regenerative resistance. This energy can be found by means of the following formula: Eg = (Eg1 – Ec) + (Eg2 – Ec) [J] Ec is the regenerative energy absorbed by the capacitors. (This value varies according to the model.) If either (Eg1 – Ec) or (Eg2 – Ec) is less than zero, calculate as if it were zero. 2. Average regeneration amount (Pr): Power consumed by regenerative resistance in one cycle of operation (unit: W): Pr = Eg/T [W] T: Operation cycle [s] This average regeneration amount must be no more than the average regenerative amount for the Servo Driver. H Vertical Axle +N1 Falling Motor operation Rising –N2 ÉÉÉ ÉÉÉ ÉÉÉÉ ÉÉÉ TD2 Motor output torque Eg1 Eg2 ÉÉÉ ÉÉÉ Eg3 Tt2 TL TD1 t1 t2 t3 T Note In the output torque graph, acceleration in the positive direction (rising) is shown as positive, and acceleration in the negative direction (falling) is shown as negative. The regenerative energy for each section can be found by means of the following formulas: Eg1 = 1/2 S N1 S TD1 S t1 S 1.027 × 10–2 [J] Eg2 = N2 S TL2 S t2 S 1.027 × 10–2 [J] Eg3 = 1/2 S N2 S TD2 S t3 S 1.027 × 10–2 [J] N1, N2: TL2: Rotation speed at beginning of deceleration [r/min] Torque when declining [kgf S cm] 3-55 Chapter 3 Operation TD1, TD2: t1, t3: t2: Deceleration torque [kgf S cm] Deceleration time [s] Travel time equivalent to torque when declining [s] Note There is some loss due to winding resistance, so the actual regenerative energy will be approximately 90% of the figure derived by the formula. To find the regenerative processing capacity, it is necessary to calculate the average regenerative power. 1. Energy (Eg) consumed by regenerative resistance: The regenerative energy that cannot be absorbed by the Servo Driver’s internal capacitors is consumed by regenerative resistance. This energy can be found by means of the following formula: Eg = (Eg1 – Ec) + (Eg2+ Eg3 – Ec) [J] Ec is the regenerative energy absorbed by the capacitors. (This value varies according to the model.) If either (Eg1 – Ec) or (Eg2+ Eg3 – Ec) is less than zero, calculate as if it were zero. 2. Average regeneration amount (Pr): Power consumed by regenerative resistance in one cycle of operation (unit: W): Pr = Eg/T [W] T: Operation cycle [s] This average regeneration amount must be no more than the average regenerative amount for the Servo Driver. 3-6-2 Servo Driver Absorbable Regenerative Energy H Regenerative Energy Absorbed Internally The Servo Driver absorbs regenerative energy by means of an internal capacitor. If there is more regenerative energy than can be absorbed by the capacitor, an overvoltage error will be generated and operation cannot continue. The amounts of regenerative energy that can be absorbed by the various Servo Drivers alone are shown in the tables below. If regenerative energy exceeding these values is produced, take the following measures. • Lower the operating rotation speed. (The regenerative energy is proportional to the square of the rotation speed.) • Lengthen the deceleration time. (Reduce the amount of regenerative energy per unit time.) • Lengthen the operating cycle (i.e., the cycle time). (Reduce the average regenerative power.) Servo Driver model R88D-UT24H/V R88D-UT40H/V R88D-UT60H/V R88D-UT80H/V R88D-UT110H R88D-UT120H 3-56 Absorptive regeneration energy Ec (J) 24.3 24.3 64.3 64.3 107 107 Average absorbable regenerative energy (W) 28 28 28 28 56 56 Chapter 3 Operation Servo Driver model requiring external regenerative resistor R88D-UT24V-RG R88D-UT40V-RG R88D-UT60V-RG R88D-UT80V-RG R88D-UT110V Absorptive regeneration energy Ec (J) 24.3 24.3 64.3 64.3 119 Note 1. The Servo Drivers requiring external regenerative resistors do no have built-in regenerative resistors. Be sure to install Regenerative Resistors that correspond to the amount of regenerative energy. Note 2. The input voltage is the value at 200 VAC. As the input voltage is increased, the amount of regenerative energy that can be absorbed is decreased. 3-6-3 Absorption of Regenerative Energy with External Regenerative Resistors Connected to Models Complying with EC Directives If there is excessive regenerative energy that cannot be absorbed by the Servo Driver, use a Servo Driver model to which external regenerative resistors can be connected. An appropriate number of external regenerative resistors must be connected between the + and B terminals of the Servo Driver. Do not connect external regenerative resistors to any other terminals of the Servo Driver, otherwise the Servo Driver may be damaged. The temperature of the external regenerative resistors rises by approximately 120°C. Be sure to keep them away from any device or wiring that may be affected by heat. Be sure to attach proper heat sinks to the external regenerative resistors before use. H External Regenerative Resistor D Model Model Resistance R88A-RR22047S 47Ω±5% Nominal capacity 220 W Absorption of regenerative energy at 120°C temperature rise 70 W Heat radiating condition t1.0 x j350 (SPCC) Thermal switch output specification Operating temperature: 170°C D Combinations of External Regenerative Resistors 70 W Regenerative absorption capacity 280 W 1120 W Combination Note Make sure to combine external regenerative resistors so that their regeneration absorbing capacity exceeds the average regenerative power (Pr). 3-57 Chapter 3 Operation D Dimensions Thermal switch output H Wiring of External Regenerative Resistor The external regenerative resistor must be connected between + and B terminals (or between +1 and B terminals for the R88D-UT110V). External regenerative resistor Note Like the ALM output of the Regeneration Unit, the power source of thermal switch output should turn power off when the contact is open. Refer to 2-3-4 Peripheral Device Connection Examples. 3-58 4 Chapter 4 Application 4-1 4-2 4-3 4-4 4-5 Absolute Encoder Setup and Battery Changes Using Displays Using Monitor Output Protective and Diagnostic Functions Periodic Maintenance Chapter 4 Application Operation and Adjustment Precautions ! Caution Check the newly set parameters for proper execution before actually running them. Not doing so may result in equipment damage. ! Caution Do not make any extreme adjustments or setting changes. Doing so may result in unstable operation and injury. ! Caution Separate the Servomotor from the machine, check for proper operation, and then connect to the machine. Not doing so may cause injury. ! Caution When an alarm occurs, remove the cause, reset the alarm after confirming safety, and then resume operation. Not doing so may result in injury. ! Caution Do not come close to the machine immediately after resetting momentary power interruption to avoid an unexpected restart. (Take appropriate measures to secure safety against an unexpected restart.) Doing so may result in injury. ! Caution Do not use the built-in brake of the Servomotor for ordinary braking. Doing so may result in malfunction. 4-2 Application 4-1 Chapter 4 Absolute Encoder Setup and Battery Changes This section explains how to carry out the setup procedure and change the battery for an absolute encoder. 4-1-1 Absolute Encoder Setup [Absolute] The setup procedure is required when the mechanical rotation data is set to “0” at the time of Servomotor trial operation, or when the absolute encoder is left for more than two days without a battery connected. (If it is left for more than two days without a battery connected, the internal capacitor voltage drops and internal components may not operate properly.) H Setup Procedure Be sure to follow this procedure carefully. Any mistakes in carrying out this procedure could result in faulty operation. 1. Resetting Data Connect (short-circuit) the encoder connector terminals R and S (at the Servomotor) for at least two minutes. (Refer to the illustration on the right.) Then remove the connecting line and check to be sure that there is a maximum voltage of 0.4 V between R and S (with the S terminal as the ground). If the voltage between the terminals is more than 0.4 V, reconnect the line between them. 2. Turning On Power to the Servo Driver Be sure to wire the Servo Driver and the Servomotor properly. Connect the battery to supply battery power to the encoder and wait for several seconds. Then turn on the power to the Servo Driver. 3. Inputting the SEN Signal (CN1-4) Turn ON the SEN signal. When the SEN signal is turned ON, a +5-V power supply will be provided to the encoder. As long as there is no error, the setup procedure is complete at this point. If alarm A.00 is generated, repeat the procedure beginning with step 1. Note When removing encoder connectors, leave the power on for at least 30 minutes with the SEN signal ON. If there is to be no battery connected, the data for the amount of rotation will be retained for two days. D Setup Precautions Note 1. When connecting to the CV500-MC221/421 or C200H-MC221, carry out the setup close to the mechanical origin. Note 2. An error will be generated if the absolute data exceeds +32,767 pulses when making the initial settings for the CV500-MC221/421 or C200H-MC221. 4-3 Chapter 4 Application 4-1-2 Replacing Batteries [Absolute] H Lithium Batteries Be sure to use a battery so that position data will be retained even in case of a power interruption for the absolute encoder. The following batteries are recommended. Maker Toshiba Corp. Model ER6V Voltage 3.6 V Electrical capacity 2,000 mA • h Hitachi Maxell, Ltd. ER6 3.6 V 2,050 mA • h OMRON (made by Hitachi Maxell, Ltd.) C500-BAT08 (ER17/33) 3.6 V 1,650 mA • h Remarks One/Servo Driver Service life: Approx. 10 years One/Servo Driver Service life: Approx. 10 years One/Servo Driver Service life: Approx. 7 years Note If the Servo Driver’s internal power supply is turned OFF, the battery voltage will not be monitored. Be careful to ensure that the voltage does not fall below 2.8 V. If required, install a battery voltage drop detection circuit or monitor in the system. H Battery Replacement Method The following procedure can be used to replace the battery without losing the encoder’s rotation data. 1. Turn on the power to the Servo Driver and turn ON the SEN signal, and leave them for at least 30 minutes to charge the encoder’s internal capacitors. 2. Replace the battery. Connect the battery between the Servo Driver’s control I/O connector (CN1) pin nos. 21 and 22. 21: BAT Backup battery + input (Connect a 2.8- to 4.5-VDC battery.) 22: BATGND Backup battery – input (ground for backup battery) The battery can be replaced with the power either turned on or off. Note 1. After step number 1 above has been implemented, the encoder will operate properly for two days even with the battery removed. Note 2. When replacing the battery, be careful not to short-circuit across the battery’s plus and minus terminals. Note 3. When cutting battery lead lines, cut plus and minus lines separately. If they are cut simultaneously, they may short circuit and cause sparks. Note 4. Dispose batteries according to the specified methods. Never throw the battery into a fire, otherwise it may explode. 4-4 Chapter 4 Application 4-2 Using Displays OMRON U-series AC Servomotors have unique servo software that enables quantitative monitoring in real time, on digital displays, of changes in a variety of characteristics. Use these displays for checking the various characteristics during operation. 4-2-1 Display Functions H Servo Driver Displays There are three LED indicators on the Servo Driver itself. One is for the power supply, one is for alarms, and the other is a charge indicator. Symbol POWER ALARM CHARGE Name Power supply indicator Alarm indicator Charge indicator Color Green Function Lit when control power supply is normal. Red Red Lit when error occurs. Lit when main-circuit power supply is charging. Power supply indicator Alarm indicator Charge indicator D Charge Indicator (CHARGE) Function The charge indicator lights when the voltage is added to the main-circuit power supply capacitors in the Servo Driver. ! Caution Even after the AC power supply has been interrupted, the charge lamp remains lit to indicate that voltage is remaining. Wait until this indicator turns off before touching the terminal block for inspection or any other purpose. Touching the terminal block while this indicator is lit can result in electrical shock. 4-5 Chapter 4 Application H Parameter Unit Displays When a Parameter Unit is connected, monitoring can be conducted by means of a 5-digit 7-segment LED. R88A-PR02U Handy Type R88A-PR03U Mounted Type H Parameter Unit Key Functions The contents displayed by the Parameter Unit can be changed by key operations. Handy type R88A-PR02U Mounted type R88A-PR03U RESET + Function Alarm reset Mode switching; data memory SERVO DATA DATA DATA Servo ON/OFF during jog operations Switching between parameter display and data display; data memory Increments parameter numbers and data values. Decrements parameter numbers and data values. Left shift for operation digits Right shift for operation digits 4-6 Chapter 4 Application H Types of Modes There are four types of modes for Parameter Unit displays. The functions in each mode are shown in the following table. Mode Status display mode Settings mode Monitor mode Alarm history display mode Function Bit display: Control-circuit power supply ON display, main-circuit power supply ON display, base block, positioning completion/speed conformity, rotation detection, inputting command pulses / inputting speed command, inputting torque command / inputting deviation counter reset signal Symbol display: Base block, operating, forward rotation prohibited, reverse rotation prohibited, alarm display System check: Jog operations, command offset automatic adjustment, alarm history data clear, command offset manual adjustment, motor parameters check, auto-tuning Setting and checking setup parameters Setting and checking user parameters Speed feedback, speed commands, torque commands, number of pulses from U-phase, electrical angle, internal status bit display, command pulse speed display, position deviation, input pulse counter Displays contents of alarms that have been previously generated (up to a maximum of 10). H Changing the Mode Use the MODE/SET Key to change from one mode to another. Power ON (Display example) Status display mode Ć bb Settings mode Monitor mode Alarm history display mode c n Ć0 0 u n Ć0 0 0 Ć a.0 2 4-7 Chapter 4 Application 4-2-2 Status Display Mode The status display mode is entered when powering up or by means of the MODE/SET Key. In the status display mode, Servo Driver status is displayed in two ways: bit data and symbols. These displays are shown in the following illustration. Positioning completion (position control) Speed conformity (speed control) Rotation detected Command pulses being input (position control) Speed commands being input (position control) b Base block Control-circuit power supply ON b Main-circuit power supply ON Torque commands being input (torque control) Deviation counter reset signal being input (position control) Bit data display Symbol display H Bit Data Display Contents Bit data Control-circuit power supply ON Main-circuit power supply ON Base block Positioning completion Speed conformity Rotation detection Inputting command pulses Inputting speed command Inputting torque command Inputting deviation counter reset signal Contents Lit when Servo Driver control-circuit power supply is ON. Lit when Servo Driver main-circuit power supply is ON. Lit during base block (no power to motor); dimmed when servo is ON. Lit when the residual pulses in the deviation counter fall below the positioning completion range set for Cn-1b. Lit when the motor rotation speed is within the range of (speed command value ± [Cn-22 set value]). Lit when the motor rotation speed is equal to or greater than the rotation speed for motor rotation detection (Cn-0b). Lit when command pulses are being input. Lit when a speed command input meets the rotation speed for motor rotation detection (Cn-0b). Lit when a torque command at least 10% of the rated torque is input. Lit when the deviation counter reset signal is being input. H Symbol Display Contents Symbol display bb rUn p%t n%t a.jj 4-8 Contents Base block (no power to motor) Operating Forward rotation prohibited Reverse rotation prohibited Alarm display (Refer to alarm table.) Chapter 4 Application 4-2-3 Monitor Mode H Types of Monitoring In monitor mode, ten types of monitoring can be carried out. Monitor no. Monitor contents 00 Speed feedback 01 Speed command Unit r/min r/min 02 Torque command % 03 Number of pulses from U-phase edge Pulses Explanation Displays actual rotation speed of motor. Displays command to speed loop. (The display is “0” for position control by pulse train input.) The command to the current loop is displayed as 100% of the rated torque. The number of pulses from the U-phase edge is displayed in units of encoder resolution. (There is an uncertainty of about ±5 pulses.) Incremental: Displays pulse number with 1/4 turn being 4,096 pulses. 04 05 06 07 Electrical angle Internal status bit display 1 Internal status bit display 2 Command pulse speed display Position deviation (deviation counter) Input pulse counter 08 09 Degrees --r/min Command Command Absolute: Displays pulse number with one turn being 32,768 pulses. Displays the electrical angle of the motor. Displays y Servo Driver internal information as either i h lilit or not lilit. Calculates and displays command pulse frequency in r/min. Displays residual pulses in deviation counter by command units (input pulse standard). Counts and displays input pulses. H Operation in Monitor Mode In order to conduct monitoring, first go into monitor mode and then set the monitor number and press the DATA Key. The items in parentheses in the following explanation indicate operations using the Handytype Parameter Unit. [3] DATA u n Monitor mode Ć 0 0 Monitor no. DATA [4] 3 0 0 0 Monitor data 1. Press the MODE/SET Key to go into monitor mode. 2. Using the Up and Down (and Right and Left) Keys, set the monitor number. 3. Press the DATA Key to display the monitor data. 4. Press the DATA Key to return to the monitor number display. 5. Press the MODE/SET Key to move from monitor mode to alarm history display mode. 4-9 Chapter 4 Application H Internal Status Bit Display (Un-05, Un-06) Internal status is displayed by 7-segment bit lighting. The bit number allocation is shown in the following diagram. 13 10 14 11 15 Bit no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 4-10 Symbol ALM DBON DIR TGON 4 8 12 16 Monitor no. Un-05 7 5 9 17 1 2 6 18 3 19 20 Contents Lit when alarm is generated. Lit during dynamic brake operation. Lit when in reverse rotation mode (when Cn-02 bit no. 0 = 1). Lit when the motor rotation speed is equal to or greater than the rotation speed for motor rotation detection (Cn-0b). INP Lit when residual pulses in the deviation counter are no more than the setting of Cn-1b (positioning completion range). VCMP Lit when the motor rotation speed reaches the speed command value ± the Cn-22 set value. PCON Lit when the speed control loop is in P control. PCL/SPD1 Lit when forward rotation current limit / speed selection command 1 (CN1-45) is ON. NCL/SPD2 Lit when reverse rotation current limit / speed selection command 2 (CN1-46) is ON. SVON Lit when motor is receiving power. A Encoder A phase (Lit when there is a signal) B Encoder B phase (Lit when there is a signal) Z Encoder Z phase (Lit when there is a signal) PU Poll sensor U phase [Incremental] PV Poll sensor V phase [Incremental] PW Poll sensor W phase [Incremental] RUN Lit when run command is ON. MING/PLOCK Lit when CN1-41 is ON. (Input signal functions change according TVSEL/RDIR/ to parameter settings.) IPG POT Lit when forward drive prohibit input is ON. NOT Lit when reverse drive prohibit input is ON. SEN Lit when the sensor-on signal is ON. [Absolute] Chapter 4 Application Monitor no. Un-06 Bit no. 1 2 3 4 Symbol CW CCW ECRST CLIMT 5 6 BKIR OLWRN 7 8 9 to 20 PON READY Contents Lit during CW command pulse input. Lit during CCW command pulse input. Lit when the deviation counter reset input is ON. Lit when commands to the current loop are limited by the torque limit (Cn-08, 09, Cn-18, 19 or TREF). Lit when external brake interlock output is ON. Turns off when at least 20% of overload detection level is reached. Lit while Servo Driver’s main-circuit power supply is on. Lit if an error occurs after main-circuit power supply is turned on. (Not used.) 4-2-4 Checking Servomotor Parameters Servomotor parameters can be checked when system check mode Cn-00 is set to “04.” Servomotor parameters are the Servomotor specifications that can be controlled by that Servo Driver. They are not the specifications of the Servomotor that is connected. Use this to check whether the Servo Driver and Servomotor combination is suitable. H Servomotor Parameter Checking Operation The items in parentheses in the following explanation indicate operations using the Handy-type Parameter Unit. [1] c n Ć 0 [2] 0 DATA [3] 0 0 Ć 0 4 [5] Indicates settings mode. System check mode Data [4] [4] [4] f 0 0 0 a y 0 0 0 0 1. Using the Up and Down (and Right and Left) Keys, set parameter number “00.” (System check mode) 2. Press the DATA Key to display the Cn-00 data. 3. Using the Up and Down (and Right and Left) Keys, set data “04.” (Servomotor parameter check) 4. Press the MODE/SET Key to check the Servomotor parameters in order. 5. Press the DATA Key to return to the parameter number display. 6. Press the MODE/SET Key to move from settings mode to monitor mode. 4-11 Chapter 4 Application H Parameter Display Contents D Servomotor Parameters f 0 0 0 a Motor capacity Motor type 00: 200-V type 0A: 0F: 14: 1E: 2C: 2C: 1.0 kW 1.5 kW 2.0 kW 3.0 kW 4.0 kW 5.0 kW D Particular Specifications y 0 0 0 0 User specifications number (hexadecimal display) 4-3 Using Monitor Output The Servo Driver outputs, in analog, according to parameter settings, a voltage proportional to the Servomotor rotation speed, motor current, speed command value, and deviation counter amount. The monitor voltage is output from the monitor output connector (CN4) and from pin nos. 16 and 17 of the control I/O connector (CN1). This function can be used in situations such as making fine gain adjustments or when a meter is attached to the control panel. H Analog Monitor Output Terminals (Front of the Servo Driver) CN4 pin allocation 4-12 Chapter 4 Application H Monitor Output Circuit 47 Ω CN4-2 AM terminal Current monitor or speed command monitor / command pulse speed monitor CN1-16 47 Ω CN4-1 NM terminal Speed monitor or deviation counter monitor CN1-17 CN4-3,4 Ground CN1-1 H Setup Parameter Settings Analog monitor output contents can be selected by means of bit nos. 6 and 7 of setup parameter no. 2 (Cn-02). The settings are shown in the following table. Item Monitor switch 1 Bit no. 6 Factory setting 0 Setting Explanation 0 Takes AM (CN1-16 and CN4-2) analog monitor output as current monitor output. Takes AM (CN1-16 and CN4-2) analog monitor output as speed command monitor output (for speed control) or command pulse speed monitor output (for position control). Not valid for torque control (i.e., set to 0 V). Takes NM (CN1-17 and CN4-1) analog monitor output as speed monitor output. Takes NM (CN1-17 and CN4-1) analog monitor output as deviation counter monitor output. Not valid for speed or torque control (i.e., set to 0 V). Takes deviation monitor as x1 command units. Takes deviation monitor as x100 command units. 1 Monitor switch 2 7 0 0 1 Parameter Unit monitor switch level E 0 0 1 Note 1. When the Parameter Unit’s monitor switch level (bit no. E of Cn-02) is set to “1” (x100 command units), the deviation counter monitor output becomes 0.05 V / (x100 command units). Note 2. When the Parameter Unit’s monitor switch level (bit no. E of Cn-02) setting is changed, the change does not go into effect until the power has been turned off and then on again. (Check to be sure that the LED indicator has turned off.) 4-13 Chapter 4 Application H Monitor Output Specifications Speed monitor Speed command monitor Command pulse speed monitor Current monitor Deviation counter monitor 4-14 With 0 V as center, voltage output at 1 V/(1000 r/min) ratio. Forward rotation: (–) voltage; reverse rotation: (+) voltage Output accuracy: approximately ±10% With 0 V as center, voltage output at 2 V/(rated torque) ratio. Forward acceleration: (–) voltage; reverse acceleration: (+) voltage Output accuracy: approximately ±10% With 0 V as center, voltage output at 0.05 V/(command unit: Cn-02, bit no. E) ratio. When the deviation counter value is positive, a negative voltage is output, while a positive voltage is output when the value is negative. Output accuracy: approximately ±10% Chapter 4 Application 4-4 Protective and Diagnostic Functions 4-4-1 Alarm Displays and Alarm Code Outputs The Servo Driver has the error detection functions shown below. When an error is detected, the alarm output (ALM ) and the alarm code output (ALO1-3) are output, the Servo Driver’s internal power drive circuit is turned off, and the alarm is displayed. H Alarm Table Display l Alarm code Alarm Error detection funcALM tion i a.00 ALO1 OFF ALO2 OFF ALO3 OFF OFF a.02 OFF OFF OFF OFF a.04 OFF OFF OFF OFF a.10 a.30 ON ON OFF ON OFF OFF OFF OFF a.31 ON ON OFF OFF a.40 OFF OFF ON OFF a.51 a.71 ON ON OFF ON ON ON OFF OFF Deviation counter over Overvoltage or insufficient voltage Over speed Overload a.72 ON ON ON OFF Overload a.80 OFF OFF OFF OFF a.a1 ON ON ON OFF a.b1 OFF OFF OFF OFF Encoder error [Absolute] Radiation shield overheating Command input reading error a.c1 a.c2 ON ON OFF OFF ON ON OFF OFF Runaway detected. Phase error detected. a.c3 ON OFF ON OFF a.c4 ON OFF ON OFF a.f1 OFF ON OFF OFF a.99 OFF OFF OFF ON Encoder A or B phase wire disconnection. Encoder S phase wire disconnection. Missing phase detected. Alarm reset power supply turned on. Absolute data error [Absolute] Parameter corruption Parameter setting error Overcurrent Regeneration error Detection contents; cause of error Absolute data error at time of SEN signal input detected. The checksum for the parameters read from the EEP-ROM does not match. Incorrect parameter setting. Overcurrent detected. Regeneration circuit damaged due to large amount of regenerative energy. Deviation counter residual pulses exceeded level set for Cn-1E. Main circuit DC voltage outside of the allowable range (150 to 420 VDC). Detected at 4,950 r/min. Detected at reverse limit characteristics when 135% of the rated torque was exceeded. Detected at reverse limit characteristics for 120% to 135% of the rated torque. Error detected in the number of feedback pulses during one revolution. Abnormal temperature rise detected in radiation shield. The A/D end signal was not output from the A/D converter within a fixed time. Faulty power or encoder wiring. Connector not properly connected. Encoder not properly wired. Either Phase A or Phase B signal was disconnected or short circuited. Encoder S phase (Z phase) was disconnected or short circuited. Main-circuit power supply missing phase or disconnection detected. This is history data only, and is not an alarm. 4-15 Chapter 4 Application Display cpf00 Alarm code ALO1 ALO2 ALO3 OFF OFF OFF OFF Parameter Unit transmission error 1 cpf01 --- --- Parameter Unit transmission error 2 --- --- Alarm Error detection funcALM tion Detection contents; cause of error Data could not be transmitted after the power supply was turned on. (It no longer exists in the alarm history.) Transmission timeout error (It no longer exists in the alarm history.) Note “---” means indefinite. H Alarm Output This section explains the timing of alarm outputs when the power is turned on and when alarms occur, and it explains how to clear the alarms. D Timing Chart Power supply input ON (R/S/T/r/t or OFF L1/L2/L3/L1C/L3C) Run command RUN ON OFF Error Error occurs 6 ms min. Alarm reset RESET Alarm output ALM ON OFF Approx. 2s 6 ms max. ON OFF 0 to 35 ms max. Power to motor Power on Approx. 350 ms Power off D Alarm Output Circuit Photocoupler output circuit 31 ALM Alarm output Output specifications: 30 V, 50 mA max. When normal: Output transistor ON For alarm: Output transistor OFF 32 ALMCOM D Clearing Alarms • Any of the following three methods can be used to clear an alarm. Turn ON the alarm reset signal (RESET). Power up again. (An overcurrent error (A.10) can’t be cleared just by powering up again.) Use the Parameter Unit reset operation. 4-16 Chapter 4 Application ! Caution If an alarm is cleared while the run command (RUN) is ON, operation will begin immediately after the alarm is cleared, which could be dangerous. Turn the run command off before clearing alarms. When the run command is ON and bit 0 of setup parameter Cn-01 is set to “1” (Servo always ON), be sure that it is safe to resume operation before clearing an alarm. H Overload Characteristics (Electron Thermal Characteristics) An overload protection function (electron thermal) is built into the Servo Driver to protect against Servo Driver or Servomotor overload. If an overload (A.71 to A.72) does occur, first clear the cause of the error and then wait at least one minute for the Servomotor temperature to drop before turning on the power again. If the power is turned on again too soon, the Servomotor coil may be damaged. Operation time (s) Overload characteristics are shown in the following table. If, for example, a current of three times the Servomotor’s rated current flows continuously, it will be detected after approximately three seconds. Load ratio (%) Note The load ratio is calculated in relation to the Servomotor’s rated current. Load ratio (%) = Servomotor current Servomotor rated current × 100 4-17 Chapter 4 Application H Alarm History Display Mode The Servo Driver stores the history of the 10 most recent alarms that have been generated. The alarm history can be displayed by going into the alarm history display mode and using the Up and Down Keys. D Alarm History Display Contents • A maximum of 10 items of alarm history data can be saved. • The alarm history data item “A.99” is saved when an alarm is reset or when power is reset. D Using the Alarm History Display 0 Ć 4 Error number 0 Alarm history data 1. Press the MODE/SET Key to go to the alarm history display mode. 2. Use the Up and Down Keys to go up and down through the error occurrence numbers and display the corresponding alarm history data. (The larger the error occurrence number, the less recent the alarm is.) 3. Press the MODE/SET Key to move from alarm history display mode to status display mode. H Clearing Alarm History Data Alarm history data initialization is executed in the system check mode. The items in parentheses in the following explanation indicate operations using the Handy-type Parameter Unit. [1] c n Ć 0 [3] [2] 0 DATA 0 0 Ć 0 2 [5] Indicates settings mode. System check mode [4] Data To data display Alarm history data cleared. 1. Using the Up and Down (and Right and Left) Keys, set parameter number “00.” (System check mode) 2. Press the DATA Key to display the Cn-00 data. 3. Using the Up and Down (and Right and Left) Keys, set data “02.” (Clear alarm history data) 4. Press the MODE/SET Key to clear the alarm history data. 5. Press the DATA Key to return to the parameter number display. 6. Press the MODE/SET Key to move from settings mode to monitor mode. 4-18 Chapter 4 Application 4-4-2 Troubleshooting When an error occurs, check the error contents by means of the operating status and alarm display, investigate the cause and apply the appropriate countermeasures. H Error Diagnosis by Means of Operating Status Symptom Probable cause Items to check Countermeasures Control mode The power sup- Power supply lines are ply indicator incorrectly wired. (POWER) does not light even when the power supply is turned on. • Check the power supply voltage. • Check the power supply lines. • Correct the power supply. • Correct the wiring. Common The motor does not operate even when a command d iis given. (No alarm is output.) The RUN signal is OFF (when Cn-01 bit no. 0 is “0”). Check the RUN signal’s ON and OFF by means of the monitor mode. • Input the RUN signal. • Correct the wiring. Common The correspondence between the Servo Driver and the Servomotor is incorrect. The POT and NOT signals are OFF (when Cn-01 bit nos. 2 and 3 are “0”). Check the models. Combine models that correspond correctly. Common Check whether POT and NOT are displayed in status display mode. • Turn ON the POT and NOT signals. • If POT and NOT are not being used, set Cn-01 bit nos. 2 and 3 to “1.” Common The control mode is not right. Check the control mode selection (Cn-2b). Set the control mode to match the command type. Common The deviation counter reset input (ECRST) is ON. With monitor mode, check the ON/OFF status of the deviation counter reset signal. Check the RESET signal’s ON and OFF by means of the monitor mode. • Turn OFF the ECRST signal. • Correct the wiring. Position Turn the RESET signal OFF and take measures according to the alarm display. Set the mode to match the Controller’s command pulse type. Common Correct the wiring. Speed • Turn the PLOCK signal OFF. • Check the Cn-29 value. Inc.: Set Cn-11 to “4096.” Speed An error occurred with the RESET signal ON. The command pulse mode (bit nos. 3, 4, 5 of Cn-02) is setting is incorrect. The speed command (REF) voltage is 0 V. The motor operates momentarily, y, b then but h iti does d not operate. Check the Controller’s command pulse type and the Servo Driver’s command pulse mode. • Check the speed command by means of the monitor mode. • Check the speed command voltage. The PLOCK signal is ON. Check the PLOCK signal by means of the monitor mode (internal status bit). The setting for the number of encoder pulses is incorrect. Check the value of Cn-11. The Servomotor power lines Check the Servomotor or encoder lines are wired power line U, V, and W incorrectly. phases, and the encoder line wiring. Position Common Abs.: Set Cn-11 to “8192.” Correct the wiring. Common 4-19 Chapter 4 Application Symptom Servomotor operation is unstable. Servomotor is overheating. Probable cause Items to check Correct the wiring. Common Adjust the bias rotational speed and the positioning completion range. Position The polarity of the speed command (REF) input is wrong. Check the speed command input wiring. Correct the wiring. Speed There are eccentricities or looseness in the coupling connecting the Servomotor shaft and the mechanical system, or there are load torque fluctuations according to how the pulley gears are engaging. Gain is wrong. • Check the machinery. • Try operating the Servomotor without a load. Adjust the machinery. Common • Use auto-tuning. • Adjust the gain manually. Common The ambient temperature is too high. Check to be sure that the ambient temperature around the Servomotor is no higher than 40°C. Check to see whether anything is blocking ventilation. Lower the ambient tempera- Common ture to 40°C or lower. (Use a cooler or fan.) Ensure adequate ventilation. Common Check the torque command value by means of monitor mode. • Lighten the load. • Change to a larger capacity Servomotor. Combine models that correspond correctly. Common Fix any problems causing vibration. Common • Use auto-tuning. • Adjust the gain manually (speed loop gain). Position There is an overload. The correspondence Check the models. between the Servo Driver and the Servomotor is incorrect. The machinery is vibrating. Inspect the machinery to see whether there are any foreign objects in the movable parts, or whether there is any damage, deformation, or looseness. The speed loop gain adjustment is insufficient. Vibration is Inductive noise is occurring. occurring at the same frequency as the applicable power supply. • Check to see whether the • Shorten the control signal Servo Driver control signal lines. lines are too long. • Separate control signal • Check to see whether lines from power supply control signal lines and lines. power supply lines are too • Use a low-impedance close to each other. power supply for control signals. The Servomotor operates even when speed command is for 0 V. Check the speed command voltage. 4-20 Control mode The Servomotor power lines Check the Servomotor or encoder lines are wired power line U, V, and W incorrectly. phases, and the encoder line wiring. The bias function setting is incorrect. Ventilation is obstructed. There are unusual noises. Countermeasures The speed command voltage and the speed command input section are offset. • Adjust the speed command offset. • Use speed control mode with position lock function. (Control mode selection: Cn-2b = 10) Common Speed Common Speed Chapter 4 Application H Error Diagnosis by Means of Alarm Display (Parameter Unit) Alarm display a.00 Error content Condition when error occurred Probable cause Absolute data error [Absolute] Occurred when SEN signal turned ON. Absolute encoder malfunction Faulty wiring of absolute encoder Countermeasures • Turn ON SEN signal again. • Execute setup for absolute encoder. Correct the wiring. a.02 Parameter corruption Occurred when power was turned on. Internal memory error Replace Servo Driver. a.04 Parameter setting error Occurred when power was turned on. A user parameter was set to a value outside of the setting range previously. Change the user parameter setting so it is within the setting range. Control board defective. Control board defective. Replace Servo Driver. Replace Servo Driver. a.10 Overcurrent Occurred when power was turned on. Occurred when Servo was turned on. • Current feedback circuit Replace Servo Driver. error • Main circuit transistor module error Servomotor power line is • Correct the power line short-circuited or grounded. short-circuiting or grounding. • Measure the insulation resistance at the Servomotor itself. If there is short-circuiting, replace the Servomotor. There is faulty wiring at the Correct the wiring. U, V, or W phase, or the GR. Servomotor coil are damaged. Measure the winding resistance. If the coil are damaged, replace the Servomotor. Replace Servo Driver. a.30 Regeneration error Occurred during operation. a.31 Deviation counter over Occurred when Servomotor Servomotor power line or did not operate even when encoder line malfunction d pulse l ttrain i was command Mechanical lock is in effect. input. Correct the wiring. Occurred during highspeed rotation. Servomotor power line or encoder line malfunction Correct the wiring. Occurred during long command pulse input. Gain adjustment is insufficient. Adjust the gain. Acceleration is too sudden. Lengthen the acceleration time. Load is too large. • Lighten the load. • Select another Servomotor. Regeneration circuit component error If the Servomotor shaft is locked, unlock it. 4-21 Chapter 4 Application Alarm display a.40 Error content Condition when error occurred Probable cause Countermeasures Overvoltage; Insufficient voltg age Occurred when power was turned on. The main-circuit power supply voltage is outside of the allowable range. Occurred during Servomotor deceleration. The load inertia is too large. • The main-circuit power supply voltage must be 170 to 253 VAC. • Lengthen the deceleration time. • Select another Servomotor. Lower the voltage to within the allowable range. Occurred while lowering (vertical shaft) a.51 Overspeeding High-speed rotation occurred when command was input. The main-circuit power supply voltage has exceeded the allowable range. Gravity torque is too large. The rotation speed exceeded 4,950 r/min due to overshooting. Encoder is wired incorrectly. a.71 Overload Occurred during operation. • Add a counterbalance to the machine, and reduce the gravity torque. • Reduce the lowering speed. • Adjust the gain. • Lower the maximum speed of the command. Correct the wiring. Operating at more than 135% of the rated torque. (Effective torque) • If the Servomotor shaft is locked, unlock it. • If Servomotor power lines are incorrectly wired, correct them. • Lighten the load. • Lengthen the acceleration time. • Adjust the gain. Power supply voltage has dropped. Check the power supply voltage and raise it to within the allowable range. a.72 Overload Occurred during operation. Operating at 120% to 135% • Lighten the load. of the rated torque. (Effec• Lengthen the accelerative torque) tion time. • Adjust the gain. Power supply voltage has Check the power supply dropped. voltage and raise it to within the allowable range. a.80 Encoder error [[Absolute]] Occurred during operation. Absolute encoder faulty wiring or poor contact. Correct the wiring. Pulse counter malfunction Turn OFF the SEN signal and input the alarm reset. Then turn ON the SEN signal again. a.a1 4-22 Overheating Occurred during operation. The ambient temperature If reset is executed after for the Servo Driver is waiting for a time, operation higher than 55°C. resumes. The load torque is too high. Bring the ambient temperature for the Servo Driver down to 55°C or lower. • Lighten the load. • Lengthen the acceleration time. • Select another Servomotor. Chapter 4 Application Alarm display a.b1 Error content Condition when error occurred Command input reading g error Occurred during operation. a.c1 Runaway detected Some movement occurred at the beginning of operation. a.c2 Phase error detected Some movement occurred at the beginning of operation. Occurred when power was turned on. a.c3 Encoder A, B phase lines disconnected. Some movement occurred at the beginning of operation. Probable cause Malfunctioning of the command input reading area. Reset and then run again. Damage at the command input reading area. Replace Servo Driver. • Encoder lines wired incorrectly. • Servomotor power lines wired incorrectly. • Encoder lines wired incorrectly. • Connector contact faulty. • Incorrect setting on bit E of parameter Cn-01. Correct the wiring. • Encoder lines disconnected. • Connector contact faulty. Encoder lines wired incorrectly. a.c4 Encoder S phase lines disconnected. Countermeasures Occurred when power was turned on. Incorrect setting on bit E of parameter Cn-01. Some movement occurred at the beginning of operation. • Encoder lines disconnected. • Connector contact faulty. Encoder lines wired incorrectly. Occurred when power was turned on. Incorrect setting on bit E of parameter Cn-01. • Correct the wiring. • Insert connectors correctly. • Set bit E of Cn-01 to 0 when the incremental encoder is in use. • Set bit E of Cn-01 to 1 when the absolute encoder is in use. • Correct any disconnected lines. • Insert connectors correctly. Correct the wiring. • Set bit E of Cn-01 to 0 when the incremental encoder is in use. • Set bit E of Cn-01 to 1 when the absolute encoder is in use. • Correct any disconnected lines. • Insert connectors correctly. Correct the wiring. • Set bit E of Cn-01 to 0 when the incremental encoder is in use. • Set bit E of Cn-01 to 1 when the absolute encoder is in use. Check the main-circuit power supply wiring. a.f1 Missing phase Occurred when Servo was turned ON. • Main-circuit power supply is not on. • Main-circuit power supply has missing phase or disconnected line. cpf00 Parameter Unit transmission error 1 Parameter Unit transmission error 2 Occurred when power was turned on. Servo Driver defective. Occurred while the Parameter Unit was being g used. Internal element is malfunc- Reset and then run again. tioning. cpf01 Internal element is damaged. Replace Servo Driver. Replace Servo Driver. 4-23 Chapter 4 Application 4-5 Periodic Maintenance Maintenance and Inspection Precautions ! WARNING ! Caution Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock. Resume operation only after transferring to the new Unit the contents of the data required for operation. Not doing so may result in an unexpected operation. Servomotors and Servo Drivers contain many components and will operate properly only when each of the individual components is operating properly. Some of the electrical and mechanical components require maintenance depending on application conditions. In order to ensure proper long-term operation of Servomotors and Drivers, periodic inspection and part replacement is required according to the life of the components. The periodic maintenance cycle depends on the installation environment and application conditions of the Servomotor or Driver. Recommended maintenance times are listed below for Servomotors and Drivers. Use these are reference in determining actual maintenance schedules. H Servomotors • Recommended Periodic Maintenance Bearings: 20,000 hours Application Conditions: Ambient motor operating temperature of 40_C, within allowable shaft load, rated operation (rated torque and r/m), installed as described in operation manual. • The radial loads during operation (rotation) on timing pulleys and other components contacting belts is twice the still load. Consult with the belt and pulley manufacturers and adjust designs and system settings so that the allowable shaft load is not exceeded even during operation. If a motor is used under a shaft load exceeding the allowable limit, the motor shaft can break, the bearings can burn out, and other problems can occur. H Servo Drivers • Recommended Periodic Maintenance Aluminum analytical capacitors: 50,000 hours, at an ambient Servo Driver operating temperature of 40_C, rated operation (rated torque), installed as described in operation manual. Axle fan: 30,000 hours, at an ambient Servo Driver operating temperature of 40_C and an ambient humidity of 65% RH. • When using the Servo Driver under the continuous operation mode, cool the Servo Driver with fans and air conditioners to maintain an ambient operating temperature below 40_C. • The life of aluminum analytical capacitors is greatly affected by the ambient operating temperature. Generally speaking, an increase of 10_C in the ambient operating temperature will reduce capacitor 4-24 Application Chapter 4 life by 50%. We recommend that ambient operating temperature be lowered and the power supply time be reduced as much as possible to lengthen the maintenance times for Servo Drivers. • If the Servomotor or Servo Driver is not to be used for a long time, or if they are to be used under conditions worse than those described above, a periodic inspection schedule of five years is recommended. Please consult with OMRON to determine whether or not components need to be replaced. 4-25 5 Chapter 5 Specifications 5-1 5-2 5-3 5-4 Servo Driver Specifications Servomotor Specifications Cable Specifications Parameter Unit Specifications Chapter 5 Specifications 5-1 Servo Driver Specifications 5-1-1 General Specifications Item Operating ambient temperature Operating ambient humidity Storage ambient temperature Storage ambient humidity Storage and operating atmosphere Vibration resistance Impact resistance Insulation resistance Dielectric strength Protective structure Specifications 0°C to 55°C 20% to 85% RH (with no condensation) –20°C to 85°C 20% to 85% RH (with no condensation) No corrosive gasses. 10 to 55 Hz in X, Y, and Z directions with 0.10-mm double amplitude; acceleration: 4.9 m/s2 {0.5 G} max.; time coefficient: 8 min; 4 sweeps Acceleration 19.6 m/s2 {2 G} max., in X, Y, and Z directions, three times Between power line terminals and case: 1 MΩ min. (at 500 VDC) Between power line terminals and case: 1,500 VAC for 1 min (20 mA max.) at 50/60 Hz Built into panel. Note 1. The above items reflect individual evaluation testing. The results may differ under compounded conditions. Note 2. Absolutely do not conduct a withstand voltage test with a megger tester on the Servo driver. If such tests are conducted, internal elements may be damaged. Note 3. Depending on the operating conditions, some Servo Driver parts will require maintenance. Refer to 4-5 Periodic Maintenance for details. Note 4. The service life of the Servo driver is 50,000 hours at an average ambient temperature of 40°C at 80% of the rated torque. 5-2 Chapter 5 Specifications 5-1-2 Performance Specifications H Performance Specifications (Models Not Conforming to Standards) Item Continuous output current (0-P) Momentary maximum output current (0-P) Main circuits Input power Control circuits supply Control method [Incremental] Speed f db k feedback [Absolute] Applicable load inertia Inverter method PWM frequency [IncremenApplicable (R88M-) tal] Servomot tor [Absolute] Applicable Servomotor wattage Weight Main circuits Heating g value l Control circuits Speed control range Capacity y f analog for l Load fluctuation rate inputs Voltage fluctuation rate Temperature fluctuation rate Frequency characteristics Acceleration time setting Maximum frequency Capacity y f pulse for l Position loop gain train Electronic gear ratio inputs Positioning range Feed-forward compensation Bias setting Position acceleration constant setting R88DUT24H 8.6 A 24 A R88D -UT40H 14.0 A 40 A R88D -UT60H 17.0A 59 A R88D -UT80H 27.4 A 79 A R88D -UT110H 35.8 A 108 A R88D -UT120H 37.0 A 119 A U4K030H U5K030H Three-phase 200/230 VAC (170 to 253 V) 50/60 Hz Single-phase 200/230 VAC (170 to 253 V) 50/60 Hz All-digital servo Optical incremental encoder, 4,096 pulses/revolution Optical absolute encoder, 8,192 pulses/revolution Maximum of 10 times motor’s rotor inertia PWM method based on IGBT 3.3 kHz U1K030H U1K530H U2K030H U3K030H U1K030T U1K530T U2K030T U3K030T 1.0 kW 1.5 kW 2.0 kW 3.0 kW Approx. 4.0 kg Approx. 5.0 kg 55 W 80 W 120 W 170 W 20 W 22 W 1:5,000 0.01% at 0% to 100% (at rated rotation speed) 0% at input voltage of 170 to 253 VAC ±0.1% max. at 0 to +50°C U4K030T U5K030T 4.0 kW 5.0 kW Approx. 8.0 kg 250 W 260 W 24 W 250 Hz (at the same load as the rotor inertia) 0 to 10 s (acceleration and deceleration set separately) 200 kpps 1 to 1,000 (1/s) Setting range: 0.01 x (G1, G2) x 100 (G1, G2 = 1 to 65,535) 0 to 250 (command unit) 0% to 100% of speed command amount (pulse frequency) 0 to 450 (r/min) 0 to 64 (ms) (same setting for acceleration and deceleration) 5-3 Chapter 5 Specifications H Control Specifications (Models Conforming to EC Directives) Item Continuous output current (0-P) Momentary maximum output current (0-P) Main circuits Input power Control circuits supply Control method [Incremental] Speed f db k feedback [Absolute] Applicable load inertia Inverter method PWM frequency Applicable (R88M-) [Incremental] Servomo[Absolute] tor Applicable Servomotor wattage Weight Main circuits Heating g value l Control circuits Speed control range Capacity y f analog for l Load fluctuation rate inputs Voltage fluctuation rate Temperature fluctuation rate Frequency characteristics Acceleration time setting Maximum frequency Capacity y f pulse for l Position loop gain train Electronic gear ratio inputs Positioning range Feed-forward compensation Bias setting Position acceleration constant setting 5-4 R88DUT24V-j 8.6 A 24 A R88D -UT40V-j 14.0 A 40 A R88D -UT60V-j 17.0A 59 A R88D -UT80V-j 27.4 A 79 A R88D-UT110V 37.0 A 119 A Three-phase 200/230 VAC (170 to 253 V) 50/60 Hz Single-phase 200/230 VAC (170 to 253 V) 50/60 Hz All-digital servo Optical incremental encoder, 4,096 pulses/revolution Optical absolute encoder, 8,192 pulses/revolution Maximum of 10 times motor’s rotor inertia PWM method based on IGBT 3.3 kHz U1K030V U1K530V U2K030V U3K030V U4K030V U5K030V U1K030X U4K030X U5K030X U1K530X U2K030X U3K030X 1.0 kW 1.5 kW 2.0 kW 3.0 kW Approx. 4.0 kg Approx. 5.0 kg 55 W 80 W 120 W 170 W 20 W 22 W 1:5,000 0.01% at 0% to 100% (at rated rotation speed) 0% at input voltage of 170 to 253 VAC ±0.1% max. at 0 to +50°C 4.0 kW 5.0 kW Approx. 15.0 kg 260 W 24 W 250 Hz (at the same load as the rotor inertia) 0 to 10 s (acceleration and deceleration set separately) 200 kpps 1 to 1,000 (1/s) Setting range: 0.01 x (G1, G2) x 100 (G1, G2 = 1 to 65,535) 0 to 250 (command unit) 0% to 100% of speed command amount (pulse frequency) 0 to 450 (r/min) 0 to 64 (ms) (same setting for acceleration and deceleration) Chapter 5 Specifications H I/O Signals (Common to Models Not Conforming to Standards and those Conforming to EC Directives) Input signals Signals Specifications Speed command voltage ±2 to 10 VDC / rated rotation speed (set via parameter) (motor forward rotation by +voltage) Input impedance: Approx. 30 kΩ; circuit time constant: Approx. 47 µs Torque command volt±1 to 10 VDC / rated torque (set via parameter) age (motor forward torque by +voltage) Input impedance: Approx. 30 kΩ; circuit time constant: Approx. 47 µs Position command pulse TTL, line-driver input; photoisolation; input current: 6 mA at 3 V One of the following set via parameter: Feed pulse, forward/reverse signal, Forward pulse, reverse pulse, or 90_ phase difference (A/B phase) signal. Error counter reset input Sensor ON signal input (absolute) Sequence input Input pulse width must be as shown in diagram. TTL, line-driver input; photoisolation; input current: 6 mA at 3 V 1 mA at 5 VDC, TTL input, current to encoder on high level 24-VDC, 5-mA photocoupler input, external power supply: 24±1 VDC, 50 mA min. Run command, (gain deceleration, position lock command, control mode switch, direction command, pulse prohibit), forward/reverse current limit, (speed command 1, 2), forward/reverse drive prohibit, alarm reset Output signals Position feedback output Speed monitor output Current monitor output Sequence output Signals within parentheses can be set via parameters. A-, B-, Z-phase line driver output (EIA RS-422A) A-phase and B-phase (dividing rate setting): 16 to 4,096 pulses/revolution A-phase and B-phase (dividing rate setting): 16 to 8,192 pulses/revolution Z-phase: 1 pulse/revolution 1 V/1,000 r/min 2 V/rated torque Open collector output, 30 VDC, 50 mA Alarm output, (speed conformity/positioning completion, motor rotation detection, servo ready, current limit detection, brake interlock, overload warning, overload alarm) Open collector output, 30 VDC, 20 mA Alarm code output Signals within parentheses can be set via parameters. H Protective Functions (Common to Models Not Conforming to Standards and those Conforming to EC Directives) Signals Dynamic brake stopping Other protective functions Specifications Operates when the power supply turns off, a servo alarm is generated, an overrun occurs, or the servo turns off. Absolute data error (absolute), parameter destruction, parameter setting error, overcurrent, regenerative error, error counter overflow, overvoltage, undervoltage, overspeeding, overload, encoder errors (absolute), heating plate overheating, command input read error, overrun prevention, position misdetection, encoder A/B phase break, encode S phase break, out-of-phase detection, Parameter Unit transmission error 5-5 Chapter 5 Specifications 5-1-3 I/O Specifications H Terminal Block Specifications (Models Not Conforming to Standards) Signal R S T r t P B N U V W Function Frame ground Condition This is the ground terminal. Ground to a maximum of 100 Ω (class-3). Main circuits power supply input Control circuits power supply input Main circuit DC output (Forward) Three-phase 200/230 VAC (170 to 253 VAC) 50/60 Hz (Reverse) Servomotor U-phase output Servomotor V-phase output Servomotor W-phase output Frame ground Single-phase 200/230 VAC (170 to 253 VAC) 50/60 Hz Do not connect anything to these terminals Red These are the terminals for outputs to the Servomotor. Be sure to wire terminals correctly. e tthese ese te a s co ect y White Black Green H Terminal Block Specifications (Models Conforming to EC Directives) Signal Function Frame ground Condition This is the ground terminal. Ground to a maximum of 100 Ω (class-3). Three-phase 200/230 VAC (170 to 253 VAC) 50/60 Hz + (+1) B Main circuits power supply input Control circuits power supply input Main circuit DC output (Forward) – (Reverse) U Servomotor U-phase output Servomotor V-phase output Servomotor W-phase output Frame ground L1 L2 L3 L1C L3C V W 5-6 Single-phase 200/230 VAC (170 to 253 VAC) 50/60 Hz Be sure to connect a regenerative resistor (corresponding to the amount of regenerative energy) between the + and B terminals for the R88D-UTjV-RG and between the +1 and B terminals for the R88D-UT110V. Refer to 3-6-3 Absorption of Regenerative Energy with External Regenerative Resistors Connected to Models Complying with EC Directives for details. These are the terminals for outputs to the Servomotor. Be sure to Red wire terminals correctly. e tthese ese te a s co ect y White Black Green Chapter 5 Specifications H CN1 Control I/O Specifications (Common to Models Not Conforming to Standards and those Conforming to EC Directives) D CN1 Control Inputs Pin No. 5 Signal name REF 6 AGND 9 TREF 10 AGND 3 13 18 PCOM 7 +PULS/ CW/A Function Speed command input Speed command input ground Torque command input Torque command input ground Open collector command power supply Feed pulse, reverse pulse, or 90_ phase difference pulse (A phase) Contents ±2 to ±10 V / rated revolution Changeable C a geab e by means ea s o of use user parameter a a ete C Cn-03 03 speed command scale. Command mode Speed Torque ±1 to ±10 V / rated torque Changeable of use user parameter Cn-13 C a geab e by means ea s o a a ete C 3 torque command scale. Speed Used to use an open-collector output for CW, CCW, and ECRST signals. Connect + inputs to the terminals and connect – inputs to open-collector output terminals. Line-driver input: 6 mA at 3 V Position Open-collector input: 8 –PULS/ CW/A 11 +SIGN/ CCW/B 12 –SIGN/ CCW/B Forward/reverse signal, forward pulse, pulse or 90_ phase difference pulse (B phase) 14 –ECRST Error counter reset Line-driver input: Torque Position 15 mA at 5 V Switch via bits 3, 4, and 5 of setup parameter Cn-02. Maximum response frequency: 200 kpps Open-collector input: 6 mA at 3 V Position 15 mA at 5 V Error counter cleared on ON signal 15 +ECRST 40 RUN Run command input Switch between status signal (high level) and differential signal (rising edge) via bit A of setup parameter Cn-02. ON: Servo ON, when setup parameter Cn-01 bit All no. 0 = 0. When setup parameter Cn-01 bit no. 0 = 1, this signal is not used. (Automatically set to Servo ON.) 5-7 Chapter 5 Specifications Pin No. 41 Signal name MING TVSEL PLOCK IPG RDIR Function Gain deceleration input Control mode switch input Position lock command input Contents When user parameter CN-2b = 0 or 1, and SPD1 and SPD2 are both OFF and parameter Cn-2b = 3, 4, or 5, then ON: Decrease speed loop gain When user parameter Cn-2b = 7, 8, or 9, then ON: Change control mode When user parameter Cn-2b = 10, then Speed Switch control mode Position lock ON: position lock goes in effect if the motor rotation speed speed is no more than the position lock rotation speed (Cn-29). Pulse disable input When user parameter Cn-2b = 11, then Position (pulse disON: Command pulse inputs are ignored and the abled) motor stops. Rotation direction command inputs When user parameter Cn-2b = 3, 4, 5, or 6 and an internal set speed is selected, this is the rotation direction command for internal speed settings 1 to 3. (OFF: Forward rotation, ON: Reverse rotation) Forward rotation overtravel input (OFF when prohibited). When setup parameter Cn-01 bit no. 2 = 1, this signal is not used. Reverse rotation overtravel input (OFF when prohibited). When setup parameter Cn-01 bit no. 3 = 1, this signal is not used. ON: Servo alarm status is reset. Forward/reverse rotation current limit (PCL/NCL) when user parameter Cn-2b = 0, 1, 2, 7, 8, 9, 10, or 11 (ON: Current limit) g speed ((Cn-1F,, 20,, 21)) selector Internal setting switch i h when h user parameter C Cn-2b 2b = 3 3, 4 4, 5, or 6 42 POT Forward drive prohibit input 43 NOT Reverse drive prohibit input 44 45 RESET PCL/ SPD1 46 NCL/ SPD2 47 +24VIN 4 SEN 2 SENGND Alarm reset input Forward rotation current limit input / Speed selection command 1 input Reverse rotation current limit input / Speed selection command 2 input +24-V power sup- Power supply for pin nos. 40, 41, 42, 43, 44, 45, ply input for control and 46; +24-V input DC ON: 5-V power supplies to absolute encoder [absoSensor ON input lute] Sensor ON input The signal is not used when setup parameter ground Cn-01 bit no. 1 = 1. 21 BAT 22 BATGND 5-8 Command mode Position Backup battery + input Backup battery – input Internal setting Speed control All All All All All Speed Backup battery connector terminals for power inter- Speed ruption absolute encoder [absolute] u t o for o abso ute e code [abso ute] Chapter 5 Specifications D CN1 Control Outputs Pin No. Signal name Function Contents Command mode 1 GND Ground common Ground for the encoder output, alarm code, and monitor output All 16 AM Current monitor Voltage is output centered on 0 V according to the following ratio: 2 V/(rated torque) All Forward acceleration is negative, reverse acceleration is positive. Output accuracy is approximately 10% 17 NM Speed monitor Voltage is output centered on 0 V according to the following ratio: 1 V/(1,000 r/min) All Forward is negative, reverse is positive. Output accuracy is approximately 10% 19 +Z 20 –Z 23 P12 24 N12 Encoder Z-phase + output Encoder Z-phase – output Encoder Z-phase output (1 pulse/revolution). Line d e out ut (co o g to RS-422A). S ) driver output (conforming All Built-in command power supply y Power supply for speed commands and torque com- Speed mands. Torque Can be used for speed and torque commands by connecting an external variable resistor. The function of the following pairs of signals is set in user parameter CN-2d (output signal selection); 25 (+) and 26 (–), 27 (+) and 28 (–), 29 (+) and 30 (–) 25 to 30 VCMP INP TGON READY CLIMT Speed conformity output Output (ON) when the Servomotor speed error is within the speed conformity signal output range (Cn-22). Positioning comOutput (ON) when the position error is within the pletion output positioning completion range (Cn-1b). Servomotor rotaOutput (ON) if the Servomotor rotation speed tion detection out- exceeds the value set for the Servomotor rotation put detection speed (Cn-0b). Servo ready output Output (ON) if no errors are discovered after powering the main circuits. Current limit detec- The CLIMT signal will turned ON in any of the foltion output lowing 3 cases: Speed Position All All All • The output torque reaches the value set for the torque limit (Cn-08, -09) BKIR OLWRN OLALM Brake interlock output Overload warning output Overload alarm output • The forward/reverse rotation current limit (PCL/ NCL) is ON and the output torque reaches the external current limit set in Cn-18 or Cn-19. • The output torque reaches the analog current limit input (TREF). (When Cn-02 bit no. 8 = 1) Outputs external brake interlock signal according to setting in Cn-12, 15, and 16. Goes OFF when the effective torque exceeds 20% of the overload detection level. Goes OFF when an overload is detected. Speed All All All Goes ON when the alarm reset is input. 5-9 Chapter 5 Specifications Pin No. 31 32 33 Signal Function name ALM Alarm output ALMCOM Alarm output ground +A Encoder A-phase + output 34 –A 35 –B 36 +B 37 ALO1 38 ALO2 39 ALO3 50 FG (see note 2) Encoder A-phase – output Encoder B-phase – output Encoder B-phase + output Alarm code output 1 Alarm code output 2 Alarm code output 3 Frame ground Contents When an alarm is g generated for the Servo Driver,, h output is i OFF. OFF Open O ll ( mA, A the collector output (50 30 VDC max.) Command mode All Outputs encoder pulses divided according to user parameter Cn-0A. Line driver output (conforming to RS-422A). All Outputs encoder pulses divided according to user parameter Cn-0A. Line driver output (conforming to RS-422A). All When an alarm is generated for the Servo Driver, the contents of the alarm are output in 3-bit code. Open collector output: 30 VDC, 20 mA max. All Ground terminal for shield wire of cable and FG line. ––– Note 1. Do not connect pins no. 48 and 49. Note 2. Pin No. 50 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. D CN1 Connectors Used (50P) Receptacle at Servo Driver Soldered plug at cable side Case at cable side 5-10 10250-52A2JL 10150-3000VE 10350-52A0-008 (Sumitomo 3M) (Sumitomo 3M) (Sumitomo 3M) Chapter 5 Specifications D Pin Arrangement 2 1 Sensor ON SENGND input ground [absolute] 6 8 SEN AGND –PULS /–CW/–A Sensor ON input [absolute] 12 14 AGND –SIGN /–CCW /–B REF Speed command input 7 +PULS /+CW/+A + feed pulse, + reverse pulse, + A phase Speed command input ground 31 – feed pulse, – reverse pulse, – A phase Torque command input ground – forward/reverse signal, – forward pulse, – B phase. –ECRST – error counter reset AM Current monitor (see note 2) 33 PCOM 13 Open-collector command power BATGND N12 NM +Z BAT Backup battery – input [absolute] –B AL01 AL03 + error counter reset Speed monitor (see note 2) P12 Built-in command power supply +INP Positioning completion output (see note 1) 28 –TGON Motor rotation detection output ground (see note 1) 30 –READY Servo ready output ground (see note 1) 32 ALMCOM Alarm output ground 34 –A Encoder A-phase – output 36 +B Encoder B-phase + output 38 AL02 Alarm code output 2 Encoder A-phase + output Encoder B-phase – output Alarm code output 1 Alarm code output 3 NOT Reverse rotation drive prohibit input PCL /SPD1 Forward current limit/speed selection command 1 +24VIN Positioning completion output ground (see note 1) Alarm output 43 Backup battery + input [absolute] –INP Servo ready output (see note 1) MING 41 /PLOCK /TVSEL /IPG /RDIR Encoder Z-phase + output 26 Motor rotation detection output (see note 1) Gain deceleration, position lock, control mode, pulse disable, rotation direction 47 Built-in command power supply +A Open-collector command power 45 23 24 +ECRST Encoder Z-phase – output –Z 35 39 21 22 PCOM ALM Torque command input 37 19 20 TREF + forward/reverse signal, + 11 +SIGN /+CCW/+B forward pulse, + B phase 17 18 Open-collector command power 5 15 16 PCOM +TGON 29 +READY 9 10 Encoder output alarm code ground 27 3 4 GND 40 RUN Run command input 42 POT Forward rotation drive prohibit input 44 RESET Alarm reset input 46 NCL /SPD2 Reverse current limit/speed selection command 1 FG Frame ground (see note 3) Control DC +24-V input 48 49 25 50 Note 1. The output terminal function of CN1 pins 25 through 30 are set in user parameter Cn-2d (output signal selection). The output signals shown above are the factory settings. S Positioning completion (INP: position control)/speed conformity (VCMP: speed control) S Motor rotation detection (TGON) S Servo ready (READY) S Current limit detection (CLIMT) S Break interlock (BKIR) S Overload warning (OLWRN) S Overload alarm (OLARM) Of these, positioning completion (INP: position control)/speed conformity (VCMP: speed control) can be set for CN1 pints 25 and 26 only. Note 2. The content of the monitor output for the AM and NM terminals can be changed via setup parameter Cn-02 bits 6 and 7. 5-11 Chapter 5 Specifications Note 3. Pin No. 50 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. H Control Input Interface The input circuit for the control I/O connector (CN1) is as shown in the following diagram. External power supply 24 VDC ± 1 V 50 mA min. +24 VIN 47 RUN 40 4.7 k 3.3 k To other input circuit GNDs To other input circuits D Run Command (40: RUN) This is the input that turns on the power drive circuit for the main circuit of the Servo Driver. If this signal is not input (i.e., servo-off status), the Servomotor cannot operate. Depending on the setting of setup parameter Cn-01, bit no. 0, this signal can be bypassed. In that case, the servo will be turned on after the power is turned on. D Gain Reduction, Position Lock Command, Control Mode Switch, Rotation Direction Command, Pulse Disable (41: MING/PLOCK/TVSEL/RDIR/IPG) This input signal switches among the following five kinds of signals according to the settings of user parameter Cn-2b. • Gain Reduction (41: MING; User Parameter Cn-2b = 0 (speed control) or 1 (position control), or user parameter Cn-2b = 3, 4, or 5 and SPD1 and SPD2 (speed selection commands 1 and 2) are both OFF) Input this signal to lower the loop gain for the control loop, and to weaken servo rigidity (repellant force with respect to external force). If position control is executed without including a position loop, there may be some position deviation due to temperature drift from a device such as the A/D converter. In such a case, if a gain reduction is input, the loop gain of the speed loop will be lowered and the amount of drift will be decreased. If there is static friction torque on the load (5% or more of the rated torque), the Servomotor will completely stop. In addition, if a position loop is included, when parts are inserted after positioning, the insertion operation is made easier because the repellant force with respect to external force is weakened by the inputting of this signal. This cannot be used for the vertical shaft where a gravity load is applied, because position deviation will occur. • Position Lock Command (41: PLOCK; User Parameter Cn-2b = 10 (position lock speed control)) If position control is executed without including a position loop, there may be some position deviation due to temperature drift from a device such as the A/D converter. In such a case, if this signal is input, when the Servomotor rotation speed is less than the rotation speed set for the position lock rotation speed (user parameter Cn-29), the mode changes from speed control mode to position control mode. The Servomotor goes into position lock status and completely stops. This function can be used even for the vertical shaft where a gravity load is applied. 5-12 Chapter 5 Specifications • Control Mode Switch (41: TVSEL; User Parameter Cn-2b = 7, 8, or 9 (change control mode)) If user parameter Cn-2b is 7 (position control + speed control), the mode is switched between position control and speed control (ON: speed control). If user parameter Cn-2b is 8 (position control + torque control), the mode is switched between position control and torque control (ON: torque control). If user parameter Cn-2b is 9 (speed control + torque control), the mode is switched between speed control and torque control (ON: speed control). • Rotation Direction Command (41: RDIR; User Parameter Cn-2b = 3, 4, 5, or 6 and either SPD1 or SPD2 is ON for internally set speed) This signal becomes the rotation direction change command for when operation is carried out at the internally set speed (no. 1 through no. 3 internally set speeds). When this signal is not input, the rotation direction is forward; when it is input, the direction is reverse. • Pulse Disable (41: IPG; User Parameter Cn-2b = 11 (position control, pulse disabled) Command pulse inputs are disabled. The motor will stop when this signal goes ON and the position will be locked. D Forward/Reverse Drive Prohibit (42 POT: forward drive prohibit, Cn-01 bit 2 = 0; 43 NOT: reverse drive prohibit, Cn-01 bit 3 = 0)) These two signals are the inputs for forward and reverse drive prohibit (overtravel). When they are input, driving is possible in the respective direction. When driving is prohibited, movement will stop according to the settings of bits nos. 6, 8, and 9 of setup parameter no. 1 (Cn-01). Alarm status will not be generated at the Driver. When drive prohibit is not used, clear the function by connecting the respective signal to the external power supply +24-V GND or setting setup parameter Cn-01, bit nos. 2, 3 = 1,1. ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Stopping Methods when Forward/Reverse Drive Prohibit is OFF Bit No. 8 0 POT (NOT) is OFF Bit No. 6 0 Deceleration Method Stopped Status Dynamic brake Servo free 1 Free run 1 Bit No. 9 0 Servo free Emergency stop torque (Cn-06) 1 Servo locked See note 1. Note 1. The position loop will not operate for position control when stopping in this mode. Note 2. When torque control is being used, the stop method is determined by the status of bit 6. (The status of bit 8 is irrelevant.) D Forward/Reverse Rotation Current Limit [45, 46: (PCL/SPD1), (NCL/SPD2)] These input signals switch between the forward/reverse current limit and the speed selection command signal for the internally set speed, depending on the setting of user parameter Cn-2b. • Forward/Reverse Rotation Current Limit (45, 46: PCL, NCL; user parameter Cn-2b = 0, 1, 2, 7, 8, 9, 10, or 11) These input signals are the forward rotation current limit and the reverse rotation current limit, and they limit the current to the Servomotor. The current limit values can be set for the respective directions by means of user parameters Cn-18 and 19. The set values can be set for up to the maximum output current as 100% of the rated output current. 5-13 Chapter 5 Specifications • Speed Selection Command (45, 46: SPD1, SPD2; user parameter Cn-2b = 3, 4, 5, or 6) These input signals are the speed selection command 1 and the speed selection command 2. Depending on the combination of signals, the Servomotor speed can be controlled according to the internally set speeds, nos. 1 through 3, which are set in user parameter Cn-1F, 20, 21. At that time, the CN1-41 pin becomes the rotation direction command (RDIR). D Alarm Reset (44: RESET) This is the external reset signal input for the servo alarm. Remove the cause of the alarm and then restart operation. In order to prevent danger, either set the speed command to 0 V or turn OFF the run command before inputting the reset signal. D Sensor ON Input (4: SEN) [Absolute] Sensor ON Input Ground (2: SENGND) [Absolute] The SEN signal input circuit is shown below. +5 V High: Approx. 1 mA 7406 or equivalent 0V 0V • A PNP transistor is recommended. • Signal Levels High: 4 V min. Low: 0.7 V max. When the SEN signal turns ON (low to high), 5 V is supplied to the absolute encoder. When power is not supplied to the motor (Run command input OFF) and the SEN signal is turned OFF (high to low), the 5 V to the absolute encoder is cut off. The SEN signal is ignored while power is supplied to the motor even if it is turned OFF. Power cannot be supplied to the motor even if the Run command is received unless the SEN signal is ON. Power will also not be supplied to the motor between t6he time that the SEN signal turns ON and the encoder achieves normal operation even if the Run command is received. Do not turn ON the SEN signal for at least 3 s after turning on the power supply. Refer to the chart below to turn the SEN signal ON, OFF, and ON again. SEN signal 1.3 s min. 5-14 15 ms min. Chapter 5 Specifications D Backup Battery + Input (21: BAT) [Absolute] Backup Battery – Input (22: BATGND) [Absolute] These are the connection terminals for a backup battery for power interruption to the absolute encoder. The battery voltage is 2.8 to 4.5 V. A backup battery is not supplied with the motor or driver. Purchase a battery separately. Connect the battery as shown in the following diagram. BAT Backup battery 2.8 to 4.5 V BATGND 21 22 H Command Pulse and Error Counter Reset Interface The input circuits for the control connector’s (CN1) command pulses and error counter reset are shown in the following diagrams. Line Driver Inputs Controller side + + – – Servo Driver side 220 Ω Applicable driver: AM26L S31A or equivalent Open Collector Inputs Controller side Servo Driver side 3, 13, 18 PCOM + 220 Ω – 1 GND D + Error Counter Reset (15: +ECRST) – Error Counter Reset (14: –ECRST) The content of the error counter will be reset when the error counter reset signal turns ON and the position loop will stop operating. Input the reset signal for 20 µs minimum. The counter will not be reset if the signal is too short. Cn-02 bit no. A can be used to set either a status signal (high) or a differential signal (rising edge). 5-15 Chapter 5 Specifications D + Feed Pulse, Reverse Pulse, 90_ Phase Difference Pulse A Phase (7: +PULS/+CW/+A) – Feed Pulse, Reverse Pulse, 90_ Phase Difference Pulse A Phase (8: –PULS/–CW/–A) + Forward/Reverse Signal, Forward Pulse, 90_ Phase Difference Pulse B Phase (11: +SIGN/+CCW/+B) – Forward/Reverse Signal, Forward Pulse, 90_ Phase Difference Pulse B Phase (12: –SIGN/–CCW/–B) The function of these signals depends on the command pulse mode and the command pulse logic. • Command Pulse Mode (Cn-02 bits 5, 4, 3) Cn-02 bits 5, 4, 3 = 0, 0, 0: Feed pulse and direction signal (factory setting) Cn-02 bits 5, 4, 3 = 0, 0, 1: Forward pulse and reverse pulse Cn-02 bits 5, 4, 3 = 0, 1, 0: 90_ Phase Difference (phases A/B) (1 multiplier) Cn-02 bits 5, 4, 3 = 0, 1, 1: 90_ Phase Difference (phases A/B) (2 multiplier) Cn-02 bits 5, 4, 3 = 1, 0, 0: 90_ Phase Difference (phases A/B) (4 multiplier) • Command Pulse Logic (Cn-02 bit d) Cn-02 bit d = 0: Positive logic; Bit d = 1: Negative logic Positive Log ic Cn-02 bit 5 0 Negative 0 0 0 3 0 1 ––– 0 1 0 X1 0 1 1 X2 1 0 0 X4 0 0 0 ––– 0 5-16 4 Input Command Input pins multim ltip lse pulse plier mode ––– Feed 7: +PULS pulse and 8: –PULS direction 11: +SIGN signal 12: –SIGN 0 1 ––– 0 1 0 X1 0 1 1 X2 1 0 0 X4 Reverse pulse and forward pulse 7: +CW 8: –CW 11: +CCW 12: –CCW 90_ phase difference signals 7: +A 8: –A A 11: +B 12: –B Feed pulse and direction signal 7: +PULS 8: –PULS 11: +SIGN 12: –SIGN Reverse pulse and forward pulse 7: +CW 8: –CW 11: +CCW 12: –CCW 90_ phase difference signals 7: +A 8: –A A 11: +B 12: –B Motor forward command H Motor reverse command L L L L H H H Chapter 5 Specifications • Command Pulse Timing (Although the following wave forms are for positive logic, conditions are the same for negative logic.) Command pulse mode Feed pulse and direction signal Maximum input frequency: 200 kpps Timing Forward rotation command Reverse rotation command Direction signal t1 t1 t2 t2 t2 Feed pulse t1 t1 Reverse pulse and forward pulse Maximum input frequency: 200 kpps Reverse rotation command Forward rotation command Reverse pulse t2 Forward pulse t1 t1 90_ phase difference signals (A-/B-phase pulse) Maximum input frequency: 200 kpps Forward rotation command Reverse rotation command A phase pulse t1 t1 B phase pulse 5-17 Chapter 5 Specifications H Control Output Interface The output circuit for the control I/O connector (CN1) is as shown in the following diagram. To other output circuits Servo Driver side + External power supply 24 VDC ± 1 V Maximum operating voltage: 30 VDC Maximum output current: 50 mA (Alarm code output: 20 mA max.) Di – Di: Diode for preventing surge voltage (Use speed diodes.) D Control Output Sequence Power supply input (R, S, T, r, t,) ON OFF 300 ms Approx. 2 s Alarm output (ALM) ON OFF 200 ms (see note) Servo ready output (READY) ON OFF Positioning completion output (INP) ON OFF Brake interlock output (BKIR) ON OFF 0 to 35 ms Run command input (RUN) ON OFF Alarm reset input (RESET) ON OFF Alarm code outputs (ALO1, ALO2, ALO3) ON OFF 6ms 60ms 6 ms Note This signal will remain ON for approximately 250 ms after input of the SEN signal when using an absolute encoder. 5-18 Chapter 5 Specifications D + Speed Conformity (25/27/29: +VCMP), Positioning completion (25/27/29: +INP), Motor Rotation Detection (25/27/29: +TGON), Current Limit Detection (25/27/29: +CLIMT), Brake Interlock (25/27/29: +BKIR), Overload Warning (25/27/29: +OLWRN), Overload Alarm (25/27/29: +OLARM) – Speed Conformity (26/28/30: –VCMP), Positioning completion (26/28/30: –INP), Motor Rotation Detection (26/28/30: –TGON), Current Limit Detection (26/28/30: –CLIMT), Brake Interlock (26/28/30: –BKIR), Overload Warning (26/28/30: –OLWRN), Overload Alarm (26/28/30: –OLARM) The function of the above three pairs of output terminals is determined by the setting of user parameter Cn-2d. Any of the available functions can be set to any of the terminal pairs. Each digit in the setting corresponds to one of the output terminal pairs. A setting of 0 is allowed only for the first digit (CN1 pins 25 and 26). Set Value: 210 Setting of function for CN1-25, -26 Setting of function for CN1-27, -28 Setting of function for CN1-29, -30 Output signal function Positioning completion (INP)/Speed conformity (VCMP) Motor rotation detection (TGON) Servo ready (READY) Current Limit Detection (CLIMT) Brake Interlock (BKIR) Overload Warning (OLWRN) Overload Alarm (OLARM) Set value 0 1 2 3 4 5 6 • Speed Conformity (Speed Control Mode) This is output when the speed difference between the speed command and the rotation speed is equal to or less than the value set for the speed conformity signal output range (user parameter Cn-22). For example, if the speed command is for 3,000 r/min and the set value is for 50 r/min, it is output in the range from 2,950 to 3,050 r/min. • Positioning completion (Position Control Mode) This is output when the pulse count in the error counter is equal to or less than the positioning completion range (Cn-1b). If the command speed is low speed and the positioning completion range is large, the positioning completion output will remain ON. • Motor Rotation Detection Outputs when the motor rotation speed equals or exceeds the value set for user parameter Cn-0b (rotation speed for motor rotation detection). • Servo Ready This signal is output if no errors are detected after powering up the main circuits. • Current Limit Detection The CLIMT signal will turned ON in any of the following 3 cases: S The output torque reaches the limit value set in user parameter Cn-08 or Cn-09 (the forward and reverse rotation torque limits). S The forward/reverse rotation current limit (PCL/NCL) is ON and the output torque reaches the limit value set in user parameter Cn-18 or Cn-19. 5-19 Chapter 5 Specifications S The output torque is limited by the analog voltage input through TREF when Cn-02 bit no. 8 = 1 (speed control mode only). • Brake Interlock This signal outputs an external brake timing signal according to the setting of Cn-12, -15, and -16. Refer to 3-3-14 Brake Interlock for details. • Overload Warning This signal goes OFF when the effective torque exceeds 20% of the overload detection level. • Overload Alarm This signal goes OFF when an overload is detected. The signal will go ON when the alarm reset is input. D Alarm Output (31: ALM) Alarm Output Ground (32: ALMCOM) When the Servo Driver detects an error, outputs are turned OFF. At that time, an alarm code (see below) is output according to the contents of the error. This output is OFF at the time of powering up, and turns ON when the power-up processing is completed. D Alarm Code Outputs 1 to 3 (37, 38, 39: ALO1 to ALO3) When a Servo Driver error is generated, the contents of the error are output in 3-bit code. The alarm code output ground common is CN1 pin 1 or 2. For details, refer to 4-4-1 Alarm Displays and Alarm Code Outputs. D Encoder A-, B-, and Z-phase Outputs (33, 34: +A, -A; 36, 35: +B, -B; 19, 20: +Z, -Z) Servomotor encoder signals are output as divided phase-difference pulses according to the user parameter encoder divider rate setting (Cn-0A). The output form is line driver output, and conforms to EIA-RS-422A. Receive with a line driver or high-speed photocoupler. • Output Phase (When Encoder Divider Rate Setting is 4,096) [Incremental] Forward Rotation Side Reverse Rotation Side A-phase A-phase B-phase B-phase Z-phase Z-phase • Output Phase (When Encoder Divider Rate Setting is 8,192) [Absolute] Forward Rotation Side Reverse Rotation Side A-phase A-phase B-phase B-phase Z-phase Z-phase 5-20 Chapter 5 Specifications Note 1. The Z and A phases are synced, but the pulse width can be shorter than phase A. Note 2. Absolute data is first output from phase A as serial data when the SEN signal goes ON (low to high) and then it is output as the initial incremental pulses A and B (90_ phase difference pulse). Finally, the same output operation as for a normal incremental corder (90_ phase difference pulse) is carried out. Note 3. The normal incremental encoder signals (phases A and B) are output approximately 400 ms after the SEN signal is input. • Output Circuit and Receiving Circuit [Incremental] Controller on User’s Side Servo Driver A-phase CN133 +A +A 34 –A –A 36 +B +B 35 –B –B 19 +Z +Z 20 –Z –Z 2 R 16 3 +5 V A-phase 1 4 B-phase 6 R 5 B-phase 7 12 Z-phase Output line driver SN75ALS 194NS or equivalent R 11 8 9 Z-phase 0V 1 GND 0V GND 0V 50 FG 10 (See note) FG Applicable line receiver TI-SN75175/MC3486/AM26LS32 R: 220 Ω to 470 Ω FG Note Pin No. 50 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. 5-21 Chapter 5 Specifications H Control I/O Signal Connections and External Signal Processing for Positioning Control Positioning completion Reverse pulse Forward pulse Maximum operating voltage: 30 VDC Maximum output current: 50 mA Error counter reset Servo ready Alarm output Do not connect these pins Alarm code outputs Maximum operating voltage: 30 VDC Maximum output current: 20 mA Current monitor (2 V/rated torque) Speed monitor (1 V/(1,000 r/min)) 24 VDC Encoder A, B, and Z phase outputs Line driver output EIA-RS422A conforming (Load resistance: 200 Ω max.) +24 VIN Run command Gain deceleration Forward rotation drive prohibit Reverse rotation drive prohibit Alarm reset Ground common Forward rotation current limit Frame ground Reverse rotation current limit 5-22 Note Pin No. 50 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. Chapter 5 Specifications H Control I/O Signal Connections and External Signal Processing for Speed Control Speed command Speed conformity A/D converter Torque command Motor rotation detection Power for speed and torque commands Max.: 30 mA DC Sensor ON Maximum operating voltage: 30 VDC Maximum output current: 50 mA +12 V Servo ready –12 V +5 V Alarm output 0V 0V Backup battery (2.8 to 4.5 V) Alarm code outputs Maximum operating voltage: 30 VDC Maximum output current: 20 mA Do not connect these pins Current monitor (2 V/rated torque) Speed monitor (1 V/(1,000 r/min)) +24 24 VDC Encoder A-phase outputs Run command Encoder B-phase outputs Gain deceleration Forward rotation drive prohibit Reverse rotation drive prohibit Line driver output EIA-RS422A conforming (Load resistance: 200 Ω max.) Encoder Z-phase outputs Ground common Alarm reset Forward rotation current limit Reverse rotation current limit Frame ground Note 1. Pins 2, 4, 21, and 22 are for use with an absolute encoder. Note 2. Pin No. 50 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. 5-23 Chapter 5 Specifications H CN2: Encoder Input Specifications Pin No. 1, 2, 3 4, 5, 6 7 Signal name Function E0V Encoder power supply GND E5V Encoder power supply +5 V DIR Rotation direction switch input 8, 9 10, 11 12 13 14 NC NC BAT+ BAT– S+ (Z+) 15 S– (Z–) 16 17 18 19 20 A+ A– B+ B– FG Not used Not used Battery + (see note 1) Battery – (see note 1) Encoder + S- (Z-) phase input (see note 2) Encoder – S- (Z-) phase input (see note 2) Encoder + A-phase input Encoder – A-phase input Encoder + B-phase input Encoder – B-phase input Shielded ground (see note 3) Interface Power supply y outlet for encoder: 5 V,, 400 mA Connects to GND when reverse rotation is executed by + input. Do not connect. Do not connect. Backup power output for encoder 10 µA, 3.6 V ((backup, rotation stopped)) Line driver input (conforming to EIA-RS422A) ((Input ut impedance: eda ce 220 0 Ω)) Line driver input ((conforming g to EIA-RS422A)) (I (Input impedance: i d 220 Ω)) Line driver input ((conforming g to EIA-RS422A)) (I (Input impedance: i d 220 Ω)) Cable shielded ground Note 1. These terminals are for an absolute encoder. Note 2. Incremental encoders use the S phase; absolute encoders, the Z phase. Note 3. Pin No. 20 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. D Connectors Used (20P) Receptacle at Servo Driver Soldered plug at cable side Case at cable side 10220-52A2JL 10120-3000VE 10320-52A0-008 (Sumitomo 3M) (Sumitomo 3M) (Sumitomo 3M) D Pin Arrangement 1 2 E0V Encoder power supply GND E5V E5V E5V Encoder power supply +5 V DIR Encoder power supply GND Encoder power supply +5 V 14 S+ (Z+) Rotation direction switch input 18 B+ NC 9 10 NC 11 16 A+ 7 8 E0V Encoder power supply +5 V 5 6 Encoder power supply GND 12 BAT+ 3 4 E0V Battery + (see note) Encoder + A-phase input 5-24 Battery – (see note) 15 S– (Z–) Encoder – S- (Z-) phase input 17 A– Encoder – A-phase input 19 B– Encoder – B-phase input Encoder + B-phase input Frame ground (See note 2.) Note 1. The battery pins are for an absolute encoder. 13 BAT– Encoder + S- (Z-) phase input NC 20 FG NC Chapter 5 Specifications Note 2. Pin No. 20 is open for models conforming to the EC Directives. Connect the cable shield to the connector case and ground it directly using a clamp. D Rotation Direction Change (7: DIR) To set up the mechanical configuration so that a + voltage input causes reverse rotation instead of forward rotation, this terminal can be connected to the GND terminal for any of pins 1 through 3. This function carries out the same operation by means of setting setup parameter Cn-02 bit no. 0 to “1.” Use this to prevent runaway when replacing the Servo Driver. When the rotation direction is changed, the encoder A-phase and B-phase output phases are also changed. The following example is for speed control: When not set (factory setting), + voltage is for forward (CCW) rotation and A-phase advance; when set, + voltage if for reverse (CW) rotation and A-phase advance (and – voltage is for forward rotation and B-phase advance). Therefore wiring changes are unnecessary for encoder signals to the positioner. D Encoder Pulse Input Signals (A-, B-, S-phase (incremental), Z-phase (absolute)) Inputs signals output from the Servomotor encoder. In S-phase, servo sensor U-, V-, W-, and Z-phase are transmitted according to A- and B-phase logic. D Encoder Power Supply + 5-V Output and Ground (1, 2, 3: E0V; 4, 5, 6: E5V) Outputs +5.2 ±0.1 V as the power supply for the Servomotor encoder. The encoder power supply cannot be used for other purposes. H CN3: Parameter Unit Input Specifications Pin No. 1 2 3 4 5 Signal name TXD+ TXD– RXD+ RXD– PRMU Function Transmission data + Transmission data – Reception data + Reception data – Unit switching 6 RT1 Termination resistance enabled/disabled 7 RT2 8 9 +5V GND +5 V output Ground I/O interface This is data transmitted to a Parameter Unit ((or a personall computer). ) This is data received from a Parameter Unit ((or a personall computer). ) This is the switching terminal for a Parameter Unit or personal computer. If the pin is open, it is for a personal computer. If connected to +5V, it is for a Parameter Unit. This is the termination resistance terminal for the line receiver. For 1 1-to-1 to 1 communications or for the final Servo Driver, short-circuit RT1-RT2. This is the +5 V output to the Parameter Unit. 5-25 Chapter 5 Specifications D Pin Arrangement 1 TXD+ Transmission data + 6 2 3 4 5 TXD– RXD+ RXD– PRMU RT1 Termination resistance on/off Transmission data – 7 RT2 8 +5V +5-V output 9 GND Ground Reception data + Reception data – Unit switching D Connectors Used (D-sub Connector, 9P) Socket at Servo Driver Soldered plug at cable side Cover at cable side 17LE-13090-27 (D2BC) (DDK) 17JE-23090-02 (D1) (DDK) (XM2A-0901 (OMRON)) 17JE-09H-15 (DDK) (XM2S-0912 (OMRON)) H CN4: Monitor Output Connector Specifications Function Speed monitor I/O interface Voltage output with a ratio of 1 V/(1,000 r/min), centered at 0 V. Speed command monitor (–) voltage is forward, (+) voltage is reverse, and output accuracy is about ±10%. Command pulse speed monitor Current monitor Error counter monitor Voltage output with a ratio of 2 V / (rated torque), centered at 0 V. (–) voltage is output during forward acceleration and positive voltage during reverse acceleration. Output accuracy is about ±10%. Voltage output with a ratio of 0.05 V/(command unit: Cn-o2 bit E), centered at 0 V. (–) voltage is a positive count, (+) voltage is a negative count, and output accuracy is about ±10%. D Connectors Used (4P) Pin header at Servo Driver Socket at cable side Socket crimp-type terminal at cable side 5-26 DF11-4DP-2DS DF11-4DS-2C DF11-2428 SC (Hirose Electric ) (Hirose Electric ) (Hirose Electric ) Chapter 5 Specifications 5-1-4 Explanation of User Parameters Refer to 3-3-2 Setting and Checking User Parameters (Cn-03 to 2d) for a table of user parameters. D Speed Command Scale: Cn-03 (Speed, Torque) This is a constant for adjusting the motor rotation speed for the speed command input. The adjustable range is 10 to 2,000 (r/min/V). The factory setting is for 300 (r/min/V), with an input voltage of 10 V at 3,000 r/min. Rotation speed (r/min) Maximum rotation speed Rated rotation speed 3000 r/min 6V Setting at time of shipping 3000 r/min 10V Speed command input voltage (V) When a position control loop is formed for a speed command type, this speed command scale becomes the position loop gain. Specifications Chapter 5 D Speed Loop Gain: Cn-04 (Position, Speed) This is the proportional gain for the speed controller. The adjustable range is 1 to 2,000 Hz (the response frequency when equivalent inertia is used). As the number is increased, the gain is increased. The factory setting is for 80 (Hz). Using the factory setting for the Servomotor alone or with a small load inertia will cause vibration to occur, so set the value to a maximum of 20 (Hz) for operation. D Speed Loop Integration Time Constant: Cn-05 (Position, Speed) This is the integration time for the speed controller. The adjustable range is 200 to 51,200 (0.01 ms), and it is factory set to 2,000. As the number is increased, the gain is increased. D Emergency Stop Torque: Cn-06 (Position, Speed) When setup parameter Cn-01 bit no. 8 = 1, this sets the braking torque for over-travel stopping (forward/ reverse drive prohibit input operation). The setting range is 0% to 350% of maximum torque (a percentage of the braking torque as 100% of the Servomotor rated torque). The factory setting is for 350% of the maximum torque. D Software Start Acceleration Time: Cn-07 (Speed) Software Start Deceleration Time: Cn-23 (Speed) The Servomotor rotation acceleration time from 0 r/min to 4,500 r/min is set in Cn-07, and the deceleration time from 4,500 r/min to 0 r/min is set in Cn-23. The factory setting is for 0 (ms). Set to 0 (ms) when positioning is controlled by connecting a positioner with an acceleration function or when the speed control mode is not being used. Set both the acceleration and deceleration times when using these functions. D Forward Rotation Torque Control: Cn-08 (Position, Speed, Torque) Reverse Rotation Torque Control: Cn-09 (Position, Speed, Torque) The Servomotor output torque control value for forward rotation is sen in Cn-08, and the value for reverse rotation is set in Cn-09. The setting range is 0% to 350% of the maximum torque, and the factory setting is for 350% of the maximum torque. D Encoder Dividing Rate Setting: Cn-0A (Position, Speed, Torque) The number of pulses detected (A- and B-pulses) per encoder revolution is converted to the number of pulses set for this parameter and output from the Servo Driver. The setting range is 16 to 8,192 pulses/ revolution, and the factory setting is for 1,000 (pulses/revolution). The upper limit of the setting range is 4,096 for incremental encoders and 8,192 for absolute encoders. D Rotation Speed for Servomotor Rotation Detection: Cn-0b (Position, Speed, Torque) This sets the rotation speed for detecting whether or not the Servomotor is rotating. The setting range is 1 to 4,500 r/min. When motor rotation detection has been set for the output signal switch (Cn-2d = 1), the Servomotor rotation detection output (TGON) is turned ON if the Servomotor rotational speed meets or exceeds this set value. The factory setting is for 20 (r/min). 5-28 Specifications Chapter 5 D P Control Switching (Torque Command): Cn-0C (Position, Speed) P Control Switching (Speed Command): Cn-0d (Position, Speed) P Control Switching (Acceleration Command): Cn-0E (Position, Speed) P Control Switching (Error Pulse): Cn-0F (Position) These set the various points for switching the speed controller from PI control to P control in order to moderate excessive characteristics when an operation such as acceleration or deceleration is executed accompanied by output saturation of the controller. These parameters are enabled by setting the P control switching selection (Cn-01 bit b) to 1. The selections are made by setting the setup parameter Cn-01 bit nos. d and C. P Control Switching (Torque Command) is set between 0% and 350% as a percentage of the rated torque. The factory setting is 200%. P Control Switching (Speed Command) is set between 0 and 4,500 r/min. The factory setting is 0. P Control Switching (Acceleration Command) is set between 0 and 3,000 in units of 10 (r/min)/s. The factory setting is 0. P Control Switching (error pulse) is set between 0 and 10,000 in command units. The factory setting is 10. D Jog Speed: Cn-10 (Position, Speed, Torque) This sets the speed for manual operation. The setting range is 0 to 4,500 r/min. During manual operation, operating commands are given from the Parameter Unit. The factory setting is for 500 (r/min). D Number of Encoder Pulses: Cn-11 (Position, Speed, Torque) This sets the number of pulses per revolution of a connected encoder. The setting is either 4,096 for an incremental encoder or 8,192 for an absolute encoder. The Servomotor might not operate correctly if any other values are used. The factory setting is for 4,096 (pulses/revolution). D Brake Timing 1: Cn-12 (Position, Speed, Torque) Brake Command Speed: Cn-15 (Position, Speed, Torque) Brake Timing 2: Cn-16 (Position, Speed, Torque) These parameters set the output timing for the brake interlock signal (BKIR), which turns the electromagnetic brake ON and OFF. The settings are enabled when the brake interlock is set in the output signal selection (Cn-2d = 4). Brake timing 1 is a parameter for Servomotors with brakes, and it sets the delay time from the time of brake interlock output (BKIR) until the servo turns off. The setting range is 0 to 50 (× 10 ms), and the factory setting is for 0 (× 10 ms). When setting the brake timing, the time when the servo turns off until the brake interlock is set to off is set as the holding time. If the run command turns off, a servo error occurs, or the main-circuit power supply turns off during operation of a Servomotor with a brake, the dynamic brake comes on (setup parameter Cn-01 bit no. 6 = 0) and Servomotor rotation speed is decreased. When the speed drops to the level of the value set for the brake command speed (Cn-15), the brake interlock output (BKIR) turns OFF. Even if the speed does not drop to the level of the value set for the brake command speed (Cn-15), the brake interlock output (BKIR) turns OFF after the time set for brake timing 2 has elapsed. (This time setting is made for the purpose of preventing damage to machinery or the Servomotor holding brake.) The setting range is 10 to 100 (× 10 ms), and the factory setting is for 50 (× 10 ms). 5-29 Chapter 5 Specifications D Torque Command Scale: Cn-13 (Speed, Torque) This sets the input voltage per rated torque for the torque command scale (TREF: CN1-1). The setting range is 10 to 100 (× 0.1 V/rated torque), and the factory setting is 30 (× 0.1 V/rated torque, for a setting of 3 V/rated torque). Motor output torque (× rated torque) At time of shipping 3 V/Rated torque 10 V/Rated torque Torque command voltage (V) D Speed Limit: Cn-14 (Torque) This limits the Servomotor rotation speed for the torque control mode and is valid in torque control mode only. The setting range is 0 to 4,500 (r/min), and the factory setting is for 3,000 (r/min). D Torque Command Filter Time Constant: Cn-17 (Position, Speed, Torque) This sets the low-pass filter time constant for the torque command. The setting range is 0 to 250 (× 100 µs), and the factory setting is 4 (× 100 µs). The relationship between the filter time constant and the cut-off frequency can be found by means of the following formula: fc (Hz) = 1 / (2ΠΤ) : Τ= Filter time constant If Τ= 400 (µs), fc will be approximately 400 (Hz). When the characteristic vibration of the machinery is within the response frequency of the servo loop, Servomotor vibration will occur. In order to prevent this sympathetic vibration based on the characteristic vibration of the machinery, set the torque filter time constant to a value that will eliminate the vibration (i.e., set it to a high value). 5-30 Specifications Chapter 5 D Forward Rotation External Current Limit: Cn-18 (Position, Speed, Torque) Reverse Rotation External Current Limit: Cn-19 (Position, Speed, Torque) These set the Servomotor output torque limits for the forward and reverse directions. The are valid when when the forward/reverse current limits (PCL/NCL) are input. This function can’t be used when the control mode is “internal speed control settings.” The setting range is 0% to 350% of the maximum torque, and the factory setting is for the 100 (%). D Position Loop Gain: Cn-1A (Position, Speed) It is valid for position control and position lock status. The setting range is 1 to 1,000 (1/s), and the factory setting is 40 (1/s). Set to between 50 and 70 for general NC machine tools, to between 30 and 50 for general-purpose machine assembly machines, and to between 10 and 30 for industrial robots. If the position loop gain is set too high for systems with low machine hardness or for systems with low inherit vibrations, machine resonance can result, causing an overload alarm. D Positioning Completion Range: Cn-1b (Position) This sets the error counter value for outputting the positioning completion signal (INP). The positioning completion output will be ON when the error counter is at or below this value. The setting range is 0 to 250 in command units and the factory setting is 3. D Bias Rotational Speed: Cn-1C (Position) This is the position control bias setting. It can be used according to the load conditions to reduce the positioning time. The setting range is 0 to 450 in r/min and the factory setting is 0. D Feed-forward Amount: Cn-1d (Position) This is the compensation value for position control feed-forward. Positioning time is reduced by adding the differential of the command pulse to the speed command. The setting range is 0% to 100% and the factory setting is 0%. D Deviation Counter Over Level: Cn-1E (Position) This is the setting for detection level for deviation counter overrun. A servo alarm will be generated if the error counter exceeds this value. The setting range is 1 to 32,767 in x256 command units and the factory setting is 1,024. D No. 1 Internal Speed Setting: Cn-1F (Factory Setting: 100 r/min) (Speed) No. 2 Internal Speed Setting: Cn-20 (Factory Setting: 200 r/min) (Speed) No. 3 Internal Speed Setting: Cn-21 (Factory Setting: 200 r/min) (Speed) Make these settings to control speeds by means of internal settings. The setting range is 0 to 4,500 (r/min). For details, refer to 3-3-4 Setting Internal Speed Control. D Speed Conformity Signal Output Range: Cn-22 (Speed) When the absolute value of the difference between the speed command and the Servomotor rotation speed (the speed deviation) is equal to or less than the set value, the speed conformity output (VCMP) turns ON. This parameter is valid in the speed control mode when the speed conformity output is set for the output signal selection. (Cn-2d = 0) 5-31 Specifications Chapter 5 If the speed command is for 2,000 (r/min) and the speed conformity signal output range is 100 (r/min), then the speed conformity output (VCMP) turns ON when the Servomotor rotation speed is between 1,900 (r/min) and 2,100 (r/min). The setting range is 0 to 100 (r/min), and the factory setting is for 10 (r/min). D Electronic Gear Ratio G1 (Numerator): Cn-24 (Position) Electronic Gear Ratio G2 (Denominator): Cn-25 (Position) The motor will rotate via the pulse obtained by multiplying the command pulses by the electronic gear ratio G1/G2. The setting ranges for G1 and G2 are 1 to 65,535, but (1/100) x (G1/G2) x 100. The factory setting is 4/1, meaning that the motor will rotate once for each 4,096 pulses. D Position Command Acceleration/Deceleration Constant: Cn-26 (Position) This parameter can be used to perform smoothing processing on the command pulses to rotate the motor. This can be effective in the following cases. • There is no acceleration or deceleration in the command pulses. • The frequency of the command pulses varies rapidly. • The electronic gear ratio is large (G1/G2 y 10) The setting range is 0 to 640 in 0.1 ms units and the factory setting is 0. D Feed-forward Command Filter: Cn-27 (Position) This setting is for a low pass filter to prevent feed-forward amounts from being rapidly added. Overshooting can be prevented by using this setting when the command pulse frequency varies rapidly. The setting range is 0 to 640 in 0.1 ms units and the factory setting is 0. D Compensating Gain: Cn-28 (Position, Speed) When outputting a large torque (during acceleration, deceleration, etc.), the speed loop gain is decreased based on this setting. Motor vibration can be reduced by increasing this setting; also, the positioning time can be reduced because the speed loop gain can be set to a higher value. If this setting is too high, follow-up delays can occur during acceleration and deceleration. The setting range is 0 to 100, and the factory setting is 0. D Rotation Speed for Position Lock: Cn-29 (Speed) This sets the rotation speed for position locks, and is enabled when the control mode selection (Cn-2b) is set to 10 (position lock speed control). If the motor reaches or falls below the set speed when the position lock command input (PLOCK) is ON, the system will be changed from speed control to position control and the motor will servo-lock. The position lock force is adjusted via the position loop gain (Cn-1A). The setting range is 0 to 4,500 r/min and the factory setting is 10. 5-32 Chapter 5 Specifications D Motor Selection: Cn-2A (Position, Speed, Torque) This sets the applicable motor. The setting is determined for the output capacity of each servomotor. Confirm that the setting is appropriate for the servomotor being used. If the wrong value is used, operation will be unstable and the motor may be damaged. The setting range is between 0 and 255, and the factory setting is for an appropriate motor for each driver. Driver model R88D-UT24H R88D-UT40H R88D-UT60H R88D-UT80H R88D-UT110H R88D-UT120H Applicable motor model R88M-U1K030H-j/T-j R88M-U1K530H-j/T-j R88M-U2K030H-j/T-j R88M-U3K030H-j/T-j R88M-U4K030H-j/T-j R88M-U5K030H-j/T-j Set value 163 164 165 166 167 168 Driver model R88D-UT24V-j R88D-UT40V-j R88D-UT60V-j R88D-UT80V-j R88D-UT110V Applicable motor model R88M-U1K030V-jS1/X-jS1 R88M-U1K530V-jS1/X-jS1 R88M-U2K030V-jS1/X-jS1 R88M-U3K030V-jS1/X-jS1 R88M-U4K030V-jS1/X-jS1 R88M-U5K030V-jS1/X-jS1 Set value 163 164 165 166 167 168 Note The default setting of the R88D-UT110V is 4 kW (motor selection: “167”). When using a 5-kW motor, change the motor selection setting to “168.” D Control Mode Selection: Cn-2b (Position, Speed, Torque) This sets the control mode to speed control, position control, torque control, etc. The motor may operate unexpectedly if the wrong mode is set. Be sure to check the setting. The setting range is between 0 to 11, and the factory setting is 1 (Position control (Pulse train commands)) Control mode Speed control (Analog commands) Position control (Pulse train commands) [Factory setting] Torque control (Analog commands) Internally-set speed control Internally-set speed control ←→ Speed control (Analog commands) Internally-set speed control ←→ Position control (Pulse train commands) Internally-set speed control ←→ Torque control (Analog commands) Position control (Pulse train commands) ←→ Speed control (Analog commands) Position control (Pulse train commands) ←→ Torque control (Analog commands) Speed control (Analog commands) ←→ Torque control (Analog commands) Speed control (Analog commands) ←→ Position lock prohibit Position control (Pulse train commands) ←→ Pulse prohibit Set value 0 1 2 3 4 5 6 7 8 9 10 11 5-33 Chapter 5 Specifications D Encoder Power Supply Voltage: Cn-2C (Position, Speed, Torque) This sets the encoder power supply voltage. The Cn-2C (encoder power supply voltage) setting depends on the encoder cable length. The encoder may be damaged if the setting is wrong. Refer to the following table when making the setting. Encoder [Incremental] [Absolute] 3m 5m 52,500 52,500 10 m 15 m 54,000 55,000 20 m 55,500 57,000 The setting range is from 52,000 to 58,000 in mV units, and the factory setting is 52,500. D Output Signal Selection: Cn-2d (Position, Speed, Torque) This selects control output functions for CN1 pins 25 to 30. Each digit in the setting corresponds to one output terminal pair. A setting of 0 is allowed only for the first digit (CN1 pins 25 and 26). Example Setting 210 Function for CN1-25, 26 pins Function for CN1-27, 28 pins Function for CN1-29, 30 pins 5-34 Output signal function In position (INP) / speed conformity (VCMP) Motor rotation detection (TGON) Servo ready (READY) Current limit detection (CLIMT) Brake interlock (BKIR) Overload warning (OLWRN) Overload alarm (OLALM) Set value 0 1 2 3 4 5 6 Chapter 5 Specifications 5-2 Servomotor Specifications 5-2-1 General Specifications Item Operating ambient temperature Operating ambient humidity Storage ambient temperature Storage ambient humidity Storage and operating atmosphere Vibration resistance Impact resistance Insulation resistance Dielectric strength Run position Insulation grade Structure Protective structure Specifications 0°C to 40°C 20% to 80% RH (with no condensation) –20°C to 60°C 20% to 80% RH (with no condensation) No corrosive gasses. 10 to 150 Hz in X, Y, and Z directions with 0.2-mm double amplitude; acceleration: 24.5 m/s2 {2.5 G} max.; time coefficient: 8 min; 4 sweeps (see note 1) Acceleration 98 m/s2 {10 G} max., in X, Y, and Z directions, three times Between power line terminals and case: 10 MΩ min. (500 VDC megger) Between power line terminals and case: 1,500 VAC for 1 min (10 mA max.) at 50/60 Hz (JEC 2121) All directions Type F (JIS C4004) Totally-enclosed self-cooling Models not conforming to standards: IP-65 (IEC 34-5) (Excluding through-shaft portion. The connector used on the standard cable is IP-30). (see note 2) Models conforming to EC Directives: IP-55 (IEC 34-5) (Including through-shaft portion. The connector used on the standard cable is IP-30). Cannot be used in environment with water-soluble cutting fluids. (see note 2) V-15 (JEC2121) Flange-mounting Vibration grade Mounting method Note 1. Vibration may be amplified due to sympathetic resonance of machinery, so use the Servomotor Driver under conditions which will not exceed 19.6 m/s2 {2 G} over a long period of time. Note 2. Water-proof connectors must be used on the power and encoder cables when used in environments subject to direct contact with water. Refer to 2-1-2 Installation Conditions for the recommended connectors. Note 3. The Servomotors cannot be used in misty environments. Note 4. The above items reflect individual evaluation testing. The results may differ under compounded conditions. 5-2-2 Performance Specifications Item Rated output* Rated torque* q Unit R88M -U1K030j R88M -U1K530j R88M -U2K030j R88M -U3K030j R88M -U4K030j R88M -U5K030j W 1,000 1,500 2,000 3,000 4,000 5,000 kgfScm NSm 32.4 3.18 48.7 4.77 65.0 6.36 97.4 9.55 129 12.6 161 15.8 5-35 Chapter 5 Specifications Item Unit R88M -U1K030j R88M -U1K530j R88M -U2K030j R88M -U3K030j R88M -U4K030j R88M -U5K030j Rated rotation speed r/min 3,000 3,000 3,000 3,000 3,000 3,000 Momentary maximum rotation speed r/min 4,500 4,500 4,500 4,500 4,500 4,500 Momentary maximum torque* kgfScm 97.2 146 195 279 375 453 NSm 9.54 14.3 19.1 27.4 36.8 44.4 Momentary maximum/ rated current ratio % 279 283 350 289 304 320 Rated current* A (rms) 6.1 9.9 12.0 19.4 25.3 26.2 Momentary maximum current* A (rms) 17 28 42 56 77 84 Rotor inertia kgfScmSs2 1.78 × 10–3 kgSm2 1.74 × 10–4 (GD2/4) 2.52 × 10–3 2.47 × 10–4 3.26 × 10–3 3.19 × 10–4 7.14 × 10–3 7.00 × 10–4 9.80 × 10–3 9.60 × 10–4 12.6 × 10–3 12.3 × 10–4 Torque q constant** kgfScm/A NSm/A 6.1 0.59 5.5 0.54 5.3 0.52 5.5 0.54 5.2 0.51 5.8 0.57 Induced voltage constant* mV/ (r/min) 22.2 20.0 19.5 20.0 19.3 21.2 Power rate* kW/s 57.9 92.2 103 137 156 171 Mechanical time constant ms 0.9 0.7 0.6 0.6 0.6 0.6 Winding resistance Ω 0.67 0.31 0.19 0.10 0.063 0.057 Winding impedance mH 4.75 2.40 1.57 1.31 0.89 0.84 Electrical time constant ms 7.1 7.7 8.3 14.0 14.1 14.7 Weight [incremental] kg Approx. 4.6 Approx. 5.8 Approx. 7.0 Approx. 11 Approx. 14 Approx. 17 Weight [absolute] kg Approx. 5.0 Approx. 6.2 Approx. 7.4 Approx. 11.5 Approx. 14.5 Approx. 17.5 UT24H UT24V-j UT40H UT40V-j UT60H UT60V-j UT80H UT80H-j UT110H UT110V UT120H UT110V Corresponding Servo Driver (R88D-) Note 1. *The values for items marked by asterisks are the values at an armature winding temperature of 100°C, combined with the Servo Driver. Other values are at normal conditions (20°C, 65%). The momentary maximum torque shown above indicates a standard value. Note 2. When an AC Servomotor is continuously operated at the rated conditions, a heat radiation plate equivalent to an rectangular aluminum plate of t20 × 400 mm is required at the Servomotor flange mounting area. (This is for horizontal mounting, with nothing around the Servomotor and no interference from heat convection currents.) 5-36 Chapter 5 Specifications Caution Do not use 2-kW, 4-kW, or 5-kW servomotors within the shaded portions of the following diagrams. If the servomotor is used in these regions, the motor may heat, causing the encoder to malfunction. RM88M-U2K030j-j (2 kW) Effective torque (N.m) Ambient temperature (_C) RM88M-U4K030j-j (4 kW) Effective torque (N.m) RM88M-U5K030j-j (5 kW) Effective torque (N.m) Ambient temperature (_C) Ambient temperature (_C) 5-37 Chapter 5 Specifications H Specifications for Servomotors with Magnetic Brakes The magnetic brakes installed in Servomotors with brakes are status-holding brakes with non-magnetized operation. The magnetic brake is released when a magnetic current (24 VDC) is applied. The magnetic brake is not meant to be used for braking. Using it for braking will damage it. During Servomotor operation, be sure to release the magnetic brake by applying a magnetic voltage. The specifications for Servomotors with brakes are similar to those for Servomotors without brakes, so except for inertia and weight, the various constants are all the same. Note: The inertia for magnetic brakes is the load inertia. D Specifications for AC Servomotors With Brakes Item Unit R88M -U1K030j-B R88M -U1K530j-B R88M -U2K030j-B R88M -U3K030j-B R88M -U4K030j-B R88M -U5K030j-B Rotor inertia i kgfScmSs2 1.78 × 10–3 2.52 × 10–3 3.26 × 10–3 7.14 × 10–3 9.80 × 10–3 12.6 × 10–3 kgSm2 (GD2/4) 1.74 × 2.47 × 3.19 × 7.00 × 9.60 × 10–4 12.3 × 10–4 Brake i inertia i kgfScmSs2 0.22 × 10–3 2.1 × 10–3 kgSm2 (GD2/4) 0.22 × 10–4 2.1 × 10–4 Total inertia i kgfScmSs2 2.00 × 10–3 2.74 × 10–3 3.48 × 10–3 9.24 × 10–3 11.9 × 10–3 14.7 × 10–3 kgSm2 (GD2/4) 1.96 × 2.69 × 3.41 × 9.10 × 11.7 × 10–4 14.4 × 10–4 Weight [incremental] kg Approx. 6.0 Approx. 7.5 Approx. 8.5 Approx. 14 Approx. 17 Approx. 20 Weight [absolute] kg Approx. 6.5 Approx. 8.0 Approx. 9.0 Approx. 14.5 Approx. 17.5 Approx. 20.5 Excitation voltage V 24 VDC ±10% (No polarity) Power consumption W (at 20°C) 7 9.8 Current consumption A (at 20°C) 0.29 0.41 Static friction i torque kgfScm 80 min. 200 min. NSm 7.8 min. 20 min. Absorption time (see note 1) ms (180 max.) (180 max.) Release time (see note 1) ms (100 max.) (100 max.) Backlash --- (±0.5°) Rating --- Continuous Insulation grade --- Type F (brake only) 10–4 10–4 10–4 10–4 10–4 10–4 10–4 10–4 Note 1. The operation time measurement is the measured value with a surge killer (CR50500, by Okaya Electric Industrial Co.) installed. Note 2. The items in parentheses are reference values. 5-38 Chapter 5 Specifications 5-2-3 Torque and Rotation Speed Characteristics The following graphs show characteristics for various combinations of drivers with an armature winding temperature of 100_C (with 3-m standard cable and 200-VAC input). R88M-U1K030H-j/-U1K030T-j R88M-U1K530H-j/-U1K530T-j R88M-U2K030H-j/-U2K030T-j R88M-U1K030V-jS1/-U1K030X-jS1 R88M-U1K530V-jS1/-U1K530X-jS1 R88M-U2K030V-jS1/-U2K030X-jS1 Frequent usage Frequent usage Frequent usage Constant usage Constant usage Constant usage R88M-U3K030H-j/-U3K030T-j R88M-U4K030H-j/-U4K030T-j R88M-U5K030H-j/-U5K030T-j R88M-U3K030V-jS1/-U3K030X-jS1 R88M-U4K030V-jS1/-U4K030X-jS1 R88M-U5K030V-jS1/-U5K030X-jS1 Frequent usage Frequent usage Frequent usage Constant usage Constant usage Constant usage H Servomotor and Mechanical System Temperature Characteristics • U-series AC Servomotors use rare earth magnets (neodymium–iron magnets). The temperature coefficient for these magnets is approximately -0.13%/°C. As the temperature drops, the Servomotor’s momentary maximum torque increases, and as the temperature rises the Servomotor’s momentary maximum torque decreases. When the normal temperature of 20°C and –10°C are compared, the momentary maximum torque increases by approximately 4%. Conversely, when the magnet warms up to 80°C from the normal temperature of 20°C, the momentary maximum torque decreases by approximately 8%. • Generally, in a mechanical system, when the temperature drops the friction torque increases and the load torque becomes larger. For that reason, overloading may occur at low temperatures. In particular, in systems which use deceleration devices, the load torque at low temperatures may be nearly twice the load torque at normal temperatures. Check with a current monitor to see whether overloading is occurring at low temperatures, and how much the load torque is. Likewise, check to see whether there abnormal Servomotor overheating or alarms are occurring at high temperatures. • An increase in load friction torque visibly increases load inertia. Therefore, even if the Servo Driver parameters are adjusted at a normal temperature, there may not be optimal operation at low temperatures. Check to see whether there is optimal operation at low temperatures too. 5-39 Chapter 5 Specifications 5-2-4 Allowable Loads on Servomotor Shafts The allowable loads on Servomotor shafts are shown in the following table. Operate the Servomotor at no more than the allowable radial and thrust loads. At the time of assembly, assemble the Servomotor at no more than the momentary maximum radial and thrust loads (static pressure). Servomotor Momentary allowable radial load (static pressure) kgf R88M-U1K030j-j R88M-U1K530j-j R88M-U2K030j-j R88M-U3K030j-j R88M-U4K030j-j R88M-U5K030j-j 160 160 160 160 160 160 N 1,570 1,570 1,570 1,570 1,570 1,570 Momentary allowable thrust load (static pressure) kgf 60 60 60 120 120 120 N 590 590 590 1,170 1,170 1,170 Allowable radial load kgf 70 70 70 100 120 120 N 680 680 680 980 1,170 1,170 Allowable thrust load kgf 20 20 20 40 40 40 N 190 190 190 390 390 390 Note 1. The allowable radial load is the value at a point 5 mm from the end of the shaft. Radial load Thrust load 5 mm Note 2. The allowable radial and thrust loads are values determined with a service life of 20,000 hours taken as a criteria. Note 3. Absolutely do not impact the Servomotor or the output shaft by striking them with an implement such as a hammer. Doing so will damage the Servomotor and encoder bearings. Note 4. The service life of bearing grease is 20,000 hours at a Servomotor ambient temperature of 40°C, and under the rated operating conditions. Note 5. Make sure that the radial load is within the allowable range when there is a radial load applied. If the Servomotor is operated at more than the allowable radial load, the shaft may suffer damage due to fatigue. Note 6. Applying an excessive load even once can damage the bearings and eventually cause a breakdown. 5-40 Chapter 5 Specifications 5-2-5 Encoder Specifications Item Encoder method Number of output pulses Maximum rotational speed Power supply voltage Power supply current Applicable battery voltage Battery current consumption Phase characteristics Phase relationship Maximum rotation speed Maximum response frequency Output signals Output impedance Serial communications data Serial communications method Absolute value communications data Standards Optical encoder Incremental encoder Absolute encoder A, B phase: 4,096 pulses/revolution A, B phase: 8,192 pulses/revolution Z phase: 1 pulse/revolution Z phase: 1 pulse/revolution ––– 99,999 rotations 5 VDC±5% DC, 350 mA (for load resistance of DC, 400 mA (for load resistance of 220 Ω) 220 Ω) ––– 3.6 VDC ––– 10 µA (3.0 V; when stopped) 90° ±36° For rotation in the CW direction, A phase is advanced by 90° compared to B phase. 4,500 r/min 307.2 kHz 614.4 kHz +A, –A, +B, –B, +S, –S +A, –A, +B, –B, +Z, –Z Conforming to EIA RS-422A. Conforming to EIA RS-422A. Output based on MC3487 or equiv- Output based on SN75158 or alent. equivalent. Z phase, poll sensor, U, V, W phase ––– Combination communications ––– method based on A, B, and S phases. ––– Rotation amount data Absolute position data within one rotation (output only when power is supplied) 5-41 Chapter 5 Specifications 5-3 Cable Specifications 5-3-1 Controller Connecting Cable H Connecting Cables for CV500-MC221/421/C200H-MC221 D Types of Cable Number of axes 1 2 Model R88A-CPUB001M1 R88A-CPUB002M1 R88A-CPUB001M2 R88A-CPUB002M2 Length (L) 1m 2m 1m 2m Outer diameter of sheath 8.3 dia. 8.3 dia. D Connection Configuration (For 1 Axis) OMNUC U-series AC Servo Driver (R88D-UTj) CV500-MC221/421 C200H-MC221 5-42 Chapter 5 Specifications D Wiring (For 1 Axis) CV500-MC221/MC421 C200H-MC221 Signal Insulation color/Marking color/Marking AWG20 Red AWG20 Black OMNUC U-series AC Servo Driver Signal *AWG20 Red *AWG20 Blue 21 * 22 * White/Black – 31 Pink/Black – Yellow/Black – 40 44 Gray/Black – Gray/Red – Orange/Black – – 2 * 4 * 1 White/Red – 33 White/Black – Yellow/Red – 34 Yellow/Black – 35 Pink/Red – Pink/Black – Orange/Red – 19 36 20 5 Orange/Black – 6 Shell Orange/Black – Gray/Black – 47 32 Connector plug: 10150-3000VE (Sumitomo 3M) Connector case: 10350-52A0-008 (Sumitomo 3M) Connector plug: 10136-3000VE (Sumitomo 3M) Connector case: 10336-52A0-008 (Sumitomo 3M) Note 1. The Controller’s symbols are the DRVX-Y connector’s symbols. In a DRVZ-U connector, X → Z and Y → U. Note 2. The terminals and wires marked with asterisks are used with Absolute Encoders. Note 3. Supply 24 VDC to the two wires (black and red) that are taken out from the Controller’s connector. (Red is + and black is –.) 5-43 Specifications Chapter 5 D Connection Configuration (For 2 Axes) OMNUC U-series AC Servo Driver (R88D-UTj) CV500-MC221/421 C200H-MC221 5-44 OMNUC U-series AC Servo Driver (R88D-UTj) Chapter 5 Specifications D Wiring (For 2 Axes) CV500-MC221/MC421 C200H-MC221 Insulation color/Marking color/Marking Signal OMNUC U-series AC Servo Driver Signal AWG20 Red AWG20 Black *AWG20 Red *AWG20 Blue 21 * * 22 White/Black – 31 Pink/Black – Yellow/Black – 40 44 Gray/Black – 2 Gray/Red – Orange/Black – – 4 * * 1 White/Red – 33 White/Black – 34 Yellow/Red – 36 Yellow/Black – 35 Pink/Red – Pink/Black – 19 20 5 Orange/Red – Orange/Black – 6 Shell 47 Orange/Black – Gray/Black – 32 Signal 47 32 White/Black – 31 Pink/Black – Yellow/Black – 40 44 Gray/Black – 2 Gray/Red – Orange/Black – – 4 1 White/Red – 33 White/Black – 34 Yellow/Red – 36 Yellow/Black – 35 Pink/Red – Pink/Black – 19 20 5 Orange/Red – Orange/Black – Connector plug: 10136-3000VE (Sumitomo 3M) Connector case: 10336-52A0-008 (Sumitomo 3M) * * 6 Shell *AWG20 Red *AWG20 Blue 21 * * 22 Connector plug: 10150-3000VE (Sumitomo 3M) Connector case: 10350-52A0-008 (Sumitomo 3M) 5-45 Chapter 5 Specifications Note 1. The Controller’s symbols are the DRVX-Y connector’s symbols. In a DRVZ-U connector, X → Z and Y → U. Note 2. The terminals and wires marked with asterisks are used with Absolute Encoders. Note 3. Supply 24 VDC to the two wires (black and red) that are taken out from the Controller’s connector. (Red is + and black is –.) H General-purpose Control Cable D Types of Cable Model R88A-CPUB001S R88A-CPUB002S Length (L) 1m 2m Outer diameter of sheath 9.9 dia. D Connection Configuration SYSMAC CV-/C-series Position Control Unit OMNUC U-Series AC Servomotor Driver (R88D-UTj) 5-46 Chapter 5 Specifications D Wiring No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Insulation color Dot mark Yellow ––– Dot mark color Black Orange Orange Light gray Light gray White White Yellow Yellow – – – – – – – – Red Black Red Black Red Black Red Black Pink Pink – – Black Red Light gray Light gray –– –– Red Black Orange Orange White White Yellow Yellow Pink Pink Orange Orange Light gray Light gray White White Yellow Pink Pink Orange –– –– –– –– –– –– –– –– ––– ––– ––– ––– ––– ––– ––– ––– ––– –––– Red Black Red Black Red Black Red Black Red Black Black Red Red Black Red Red Black Red Signal name Analog EGND (GND) (SEN) REF AGND Pulse EGND (GND) PCOM (SEN) Connector Pin Arrangement 2 4 6 8 10 12 14 +CW –CW 16 18 TREF AGND 20 +CCW –CCW PCOM –ECRST +ECRST AM AM NM NM PCOM +Z +Z –Z –Z (BAT) (BAT) (BATGND) (BATGND) P12 P12 N12 N12 +VCMP +INP –VCMP –INP +TGON +TGON –TGON –TGON +READY +READY –READY –READY ALM ALM ALMCOM ALMCOM +A +A –A –A –B –B +B +B ALO1 ALO1 ALO2 ALO2 ALO3 ALO3 RUN RUN MING MING POT POT 24 22 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 26 28 30 32 34 36 38 40 42 44 46 48 50 Connector plug model: 10150-3000VE (Sumitomo 3M) Connector case model: 10350-52A0-008 (Sumitomo 3M) 5-47 Chapter 5 Specifications No. 43 44 45 46 47 48 49 50 Insulation color Dot mark Dot mark color Orange Light gray White White Light gray –––– –––– –––– –––– –––– Black Black Red Black Red Shield Cable: AWG24X18P 5-48 Signal name Analog Pulse NOT NOT RESET RESET PCL PCL NCL NCL +24VIN +24VIN FG FG Chapter 5 Specifications 5-3-2 Encoder Cable Use the recommended connectors shown in 2-1-2 Installation Conditions to conform to the EC Directives. D Types of Cable Model R88A-CRUB003N R88A-CRUB005N R88A-CRUB010N R88A-CRUB015N R88A-CRUB020N Length (L) 3m 5m 10 m 15 m 20 m Outer diameter of sheath 10.3 dia. (Up to a maximum of 20 m between the Servomotor and the Servo Driver.) D Connection Configuration 37.3 dia. OMNUC U-Series AC Servomotor (R88M-Ujjj30j-j) OMNUC U-Series AC Servomotor Driver (R88D-UTj) 5-49 Chapter 5 Specifications D Wiring Symbol No. No. Symbol AWG24 (blue) A+ A 16 A+ A– B AWG24 (white/blue) C AWG24 (yellow) 17 A– 18 B+ D AWG24 (white/yellow) E AWG24 (green) 19 B– 14 S+(Z+) F AWG24 (white/green) G AWG22 (black) 15 S–(Z–) 1 E0 V 4 E5 V 8 Not used. Not used. H AWG22 (red) AWG24 (purple) K AWG24 (white/purple) L 9 Not used. NC P Reset R AWG24 (white/gray) AWG24 (white/orange) S T AWG24 (orange) AWG22 (green/yellow) J 10 Reset 13 BAT– 12 BAT+ 20 FG B+ B– S+(Z+) S–(Z–) E0 V E5 V Not used. BAT– BAT+ FG Cable: AWG22 × 3C + AWG24 × 6P <For Cable> Connector plug model: MS3106B20-29S Cable clamp model: MS3057-12A (DDK) (DDK) <For Motor> Receptacle model: (DDK) MS3102A20-29P Contact plug model: 10120-3000VE Contact case model:10320-52A0-008 (Sumitomo 3M) (Sumitomo 3M) 5-3-3 Power Cables Use the recommended connectors shown in 2-1-2 Installation Conditions to conform to the EC Directives. H Power Cables for Servomotors Without Brakes (1.0 to 2.0 kW) D Types of Cable Model R88A-CAUB003S R88A-CAUB005S R88A-CAUB010S R88A-CAUB015S R88A-CAUB020S Length (L) 3m 5m 10 m 15 m 20 m Outer diameter of sheath 14 dia. (Up to a maximum of 20 m between the Servomotor and the Servo Driver.) 5-50 Chapter 5 Specifications D Connection Configuration OMNUC U-Series AC Servomotor (R88M-Ujjj30j-j) OMNUC U-Series AC Servomotor Driver (R88D-UTj) D Wiring Symbol No. U-phase V-phase A B W-phase C GR D Red White Black Green Cable: AWG12 × 4C Crimp-style terminal: V5.5–4 <For Cable> Connector plug model: MS3106B18-10S Cable clamp model: MS3057-10A (DDK) (DDK) <For Motor> Receptacle model: (DDK) MS3102A18-10P H Power Cables for Servomotors Without Brakes (3.0 to 5.0 kW) D Types of Cable Model R88A-CAUC003S R88A-CAUC005S R88A-CAUC010S R88A-CAUC015S R88A-CAUC020S Length (L) 3m 5m 10 m 15 m 20 m Outer diameter of sheath 16.5 dia. (Up to a maximum of 20 m between the Servomotor and the Servo Driver.) 5-51 Chapter 5 Specifications D Connection Configuration OMNUC U-Series AC Servomotor Driver (R88D-UTj) OMNUC U-Series AC Servomotor (R88M-Ujjj30j-j) D Wiring Symbol No. U-phase V-phase A B W-phase C GR D Red White Black Green Cable: AWG10 × 4C 5-52 Crimp-style terminal: V5.5–4 <For Cable> Connector plug model: MS3106B22-22S Cable clamp model: MS3057-12A (DDK) (DDK) <For Motor> Receptacle model: (DDK) MS3102A22-22P Chapter 5 Specifications H Power Cable for Servomotors With Brakes (1.0 to 2.0 kW) D Types of Cable Model R88A-CAUB003B R88A-CAUB005B R88A-CAUB010B R88A-CAUB015B R88A-CAUB020B Length (L) 3m 5m 10 m 15 m 20 m Outer diameter of sheath 16.5 dia. (Up to a maximum of 20 m between the Servomotor and the Servo Driver.) D Connection Configuration OMNUC U-Series AC Servomotor Driver (R88D-UTj) OMNUC U-Series AC Servomotor (R88M-Ujjj30j-B-j) D Wiring Symbol No. U-phase V-phase A B W-phase C GR D Brake E Brake F Red White Black Green Brown Yellow Cable: AWG12 × 6C Crimp-style terminal: V5.5–4 <For Cable> Connector plug model: MS3106B20-15S Cable clamp model: MS3057-12A (DDK) (DDK) <For Motor> Receptacle model: (DDK) MS3102A20-15P 5-53 Chapter 5 Specifications H Power Cable for Servomotors With Brakes (3.0 to 5.0 kW) D Types of Cable Model R88A-CAUC003B R88A-CAUC005B R88A-CAUC010B R88A-CAUC015B R88A-CAUC020B Length (L) 3m 5m 10 m 15 m 20 m Outer diameter of sheath 20 dia. (Up to a maximum of 20 m between the Servomotor and the Servo Driver.) D Connection Configuration OMNUC U-Series AC Servomotor Driver (R88D-UTj) OMNUC U-Series AC Servomotor (R88M-Ujjj30j-B-j) D Wiring Symbol No. U-phase V-phase A B W-phase C GR D Brake E Brake F Red White Black Green Brown Yellow Cable: AWG10 × 6C 5-54 Crimp-style terminal: V5.5–4 <For Cable> Connector plug model: MS3106B24-10S Cable clamp model: MS3057-16A (DDK) (DDK) <For Motor> Receptacle model: (DDK) MS3102A24-10P Chapter 5 Specifications 5-4 Parameter Unit Specifications H General Specifications Item Operating ambient temperature Storage ambient temperature Operating ambient humidity Storage ambient humidity Storage and operating atmosphere Vibration resistance Impact resistance Standards 0°C to 55°C –10°C to 75°C 35% to 85% RH (with no condensation) 35% to 85% RH (with no condensation) No corrosive gasses. 0.5 G {4.9 m/s2} max. Acceleration 2 G {19.6 m/s2} max. H Performance Specifications Model Type Accessory cable Connectors Display External dimensions CommuStandard nications Communications specifica- method tions Baud rate Start bits Data Parity Stop bits Errors detected by Parameter Unitt U R88A-PR02U Handy type 1,000 mm 7910-7500SC (10 pins) 7-segment LED, 5 digits 63 × 135 × 18.5 (W × H × D) RS-232C Asynchronous (ASYNC) 2,400 bps 1 bit 8 bits None 1 bit Display CPF00 CPF01 R88A-PR03U Mounted type (Connected by connectors.) D-sub connector (9 pins) 54 × 57.5 × 15 (W × H × D) RS-422A Cannot transmit even after 5 seconds have elapses since power supply was turned on. A BCC error or faulty reception data has occurred for five consecutive times, or a time overrun (1 s) has occurred for three consecutive times. 5-55 6 Chapter 6 Appendix 6-1 6-2 6-3 6-4 Connection Examples Encoder Divider Rate for Servo Controllers OMNUC U-series Standard Models Combinations of Servo Drivers and Servomotors Chapter 6 Appendix 6-1 Connection Examples H Connection Example 1: Connecting to SYSMAC C200HW-NC113 Position Control Units Main circuit power supply NFB OFF ON R Noise filter 200/230 VAC 50/60Hz X1 S MC MC Main circuit contact SUP Surge killer T Class-3 ground C200H-NC113 R88D-UTjjH CN 1 Contents 24-VDC input (for output) Pulse output 0-V input (for output) No. A1 A2 t R 24 VDC S 11 +CCW CCW (with a resistor) A6 12 -CCW CCW (without a resistor) 7 +CW CW (with a resistor) A5 A8 8 –CW CW (without a resistor) A7 X-axis dev. cntr. reset output A11 X-axis origin line driver input A16 X-axis origin common A14 A12 X-axis positioning complete input 1.6 k 15 14 +ECRST –ECRST 19 20 +Z –Z +24 VIN A19 25 47 40 X-axis origin proximity input A21 44 RESET X-axis CCW limit input A23 A22 A20 26 –INP 32 ALMCOM ALM A24 X1 X-axis external interrupt input X-axis CW limit input X-axis emerg. stop input T P MC B N Red U 24 VDC X-axis input common TB r X1 31 R88M-Ujjjjjj R88A-CAUBjjjS R88A-CAUCjjjS White V W M Black Green +INP RUN CN2 R88A-CRUBjjjN RE 24 VDC FG Shell R88A-CPUBjjjS Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver. Note 2. Leave unused signal lines open and do not wire them. Note 3. Use mode 2 for origin search. Note 4. Use the 24-VDC power supply for command pulse signals as a dedicated power supply. Note 5. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric). Note 6. Use the RUN signal to set whether the Servo can be turned ON/OFF. 6-2 Chapter 6 Appendix H Connection Example 2: Connecting to SYSMAC C200H-NC112 Position Control Units Main circuit power supply NFB OFF ON R Noise filter 200/230 VAC 50/60Hz X1 S MC MC Main circuit contact SUP Surge killer T Class-3 ground C200H-NC112 R88D-UTjjH CN 1 Contents No. 24-VDC input (for output) 1 Pulse output 5-VDC input (for output) CCW (with a resistor) CCW (without a resistor) CW (with a resistor) CW (without a resistor) 0V 2 3 4 5 Dev. counter reset output 0V Origin line driver input Positioning completion input Origin proximity input 6 A B A t R 24 VDC S B 11 +CCW A 12 -CCW B 7 +CW A 8 –CW A 15 14 +ECRST –ECRST 19 20 +Z –Z +24 VIN B 25 47 40 A 44 RESET B 26 –INP 32 ALMCOM ALM 1.6 k A 9 10 CCW limit input 12 CW limit input 13 External interrupt input 19 Emergency stop input 20 MC B N Red R88M-Ujjjjjj R88A-CAUBjjjS R88A-CAUCjjjS White V W M Black Green B A 8 T P U B B TB r B 12 to 24 VDC A B A X1 A B A X1 31 +INP RUN CN2 R88A-CRUBjjjN RE 24 VDC B FG A B Shell R88A-CPUBjjjS Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver. Note 2. Leave unused signal lines open and do not wire them. Note 3. Use mode 2 for origin search. Note 4. Use the 24-VDC power supply for command pulse signals as a dedicated power supply. Note 5. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric). Note 6. Use the RUN signal to set whether the Servo can be turned ON/OFF. 6-3 Chapter 6 Appendix H Connection Example 3: Connecting to SYSMAC C200H-NC211/C500-NC211 Position Control Units Main circuit power supply NFB OFF ON R Noise filter 200/230 VAC 50/60Hz X1 S MC MC Main circuit contact SUP Surge killer T C200H-NC211 C500-NC211 Class-3 ground R88D-UTjjH CN 1 Contents 24-VDC input (for output) No. 1 t 24 VDC X-axis pulse output 0-VDC power (for output) TB r R 23 S 11 +CCW CW (with a resistor) 2 12 -CCW T P CW (without a resistor) CCW (with a resistor) 3 13 7 8 +CW –CW B N CCW (without a resistor) 14 4 15 14 X-axis origin line driver input X-axis origin common 9 11 19 20 X-axis positioning completion input 8 25 –Z +INP 47 +24 VIN 1.6 k 22 Red U X-axis dev. cntr. reset output X/Y-axis input common MC 24 VDC +ECRST –ECRST +Z X-axis external interrupt input 6 40 RUN X-axis origin proximity input X-axis CCW limit input 7 17 44 RESET 26 –INP X-axis CW limit input 18 32 X/Y-axis emerg. stop input 19 ALMCOM ALM X1 31 R88A-CAUBjjjS R88A-CAUCjjjS White V W X1 R88M-Ujjjjjj M Black Green CN2 R88A-CRUBjjjN RE 24 VDC FG Shell FG 12 R88A-CPUBjjjS Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver. Note 2. Leave unused signal lines open and do not wire them. Note 3. Use mode 2 for origin search. Note 4. Use the 24-VDC power supply for command pulse signals as a dedicated power supply. Note 5. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric). Note 6. This wiring diagram is for the X axis only. If the other axis is to be used, connect to the Servo Driver in the same way. Note 7. Use the RUN signal to set whether the Servo can be turned ON/OFF. 6-4 Chapter 6 Appendix H Connection Example 4: Connecting to SYSMAC C200H-NC111-EV1 Position Control Units Main circuit power supply NFB OFF ON R Noise filter 200/230 VAC 50/60Hz X1 S MC MC Main circuit contact SUP Surge killer T Class-3 ground C500-NC111-EV1 Content 12 to 24 VDC CW limit CCW limit Emergency stop External interrupt Origin Origin interrupt Local R88D-UTjjH TB r 47 +24 VIN t 40 44 32 31 RUN RESET No. 1 2 3 4 5 Ready CN 1 A 24 VDC B R X1 A B A B X1 ALMCOM ALM 24 VDC A S T P B N B U A V W B MC Red R88M-Ujjjjjj R88A-CAUBjjjS R88A-CAUCjjjS White M Black Green 5 VDC Pulse output 5 VDC 8 CW+ CW– CCW+ CCW– 9 10 A B 7 8 11 +CW –CW +CCW A 12 -CCW 15 +ECRST 14 –ECRST B A B CN2 R88A-CRUBjjjN RE FG Shell R88A-CPUBjjjS Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver. Note 2. Leave unused signal lines open and do not wire them. Note 3. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric). Note 4. When an NC111-EV1 Position Control Unit is used, the origin search is executed by means of the origin and origin proximity. Establish the origin and origin proximity with respect to the mechanical system. Pulses remain accumulated in the Servo Driver’s deviation counter even after the Position Control Unit has completed the origin search and stopped pulses. This causes the Servomotor to move for the amount of residual pulses before stopping, thereby causing origin displacement. In order to minimize this, set the origin search low speed as low as possible. Note 5. Use the RUN signal to set whether the Servo can be turned ON/OFF. 6-5 Chapter 6 Appendix H Connection Example 5: Connecting to SYSMAC C200H-NC222-E Position Control Units Main circuit power supply NFB OFF ON R Noise filter 200/230 VAC 50/60Hz X1 S MC MC Main circuit contact SUP Surge killer T Class-3 ground C500-NC222-E R88D-UTjjH MD Connector Name X axis + A-phase input X axis – A-phase input X axis + B-phase input X axis – B-phase input X axis + Z-phase input X axis – Z-phase input X-A X-A X-B X-B 7 6 33 34 5 4 16 36 35 19 20 X-Z XOUT DC GND DC GND 17 +24 V +24 V 11 12 OUT 2X 2 5 6 Signal 0V DC GND X1 X-axis origin input ORG X 3 4 X-axis external servo free input SERVO X 5 X-axis CW limit input Frame ground CWL X 6 24 V for input 0V STP X FG +24 V 7 8 +24 V 9 11 DC GND 47 40 44 32 R –Z B N REF AGND S T P MC Red U White X1 31 R88M-Ujjjjjj R88A-CAUBjjjS R88A-CAUCjjjS M Black Green +24 VIN RUN RESET ALMCOM ALM 24 VDC 1 2 CCWL X t -A +B –B +Z V W No. X-axis CCW limit input X-axis extrnl. stop input +A 24 VDC EXT IN Connector Name TB r R88A-CPUBjjjS 15 9 8 1 XAG 24 V for OUT output X-axis OUT 2 output No. X-Z X-axis speed command X-axis speed cmnd., 0V 0V Signal CN 1 FG CN2 R88A-CRUBjjjN Shell RE 24 VDC Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver. Note 2. Leave unused signal lines open and do not wire them. Note 3. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric). Note 4. This wiring diagram is an example of X-axis wiring only. For two-axis control, the external input and Driver wiring must be connected for the Y axis in the same way. Note 5. External output 2 (OUT 2X) can be turned ON and OFF with external servo-free input, at which time external output 2 of the C500-NC222-E’s address numbers 420 (X axis) and 820 (Y axis) must be set to 1 (turned OFF at the time of servo free). Note 6. When the C500-NC222-E is used in NC221 mode, external servo-free input works as emergency stop input. Therefore external output 2 cannot be used as a RUN signal. Input a RUN signal from other I/O terminals. Note 7. Use the RUN signal to set whether the Servo can be turned ON/OFF. 6-6 Chapter 6 Appendix H Connection Example 6: Connecting to SYSMAC C500-MC221/421/C200H-MC221 Control Units Main circuit power supply ON OFF NFB R X Noise filter 200/230 VAC 50/60Hz X-axis external forced stop contact (emergency stop, etc.) S MC MC Main circuit contact SUP Surge killer T CV500-MC221/421 C200H-MC221 Class-3 ground DC supply DRV Connector +24 V 0 V 24-V input 24-V input ground 1 2 X-axis alarm input 3 X-axis oper. cmnd. output 4 X-axis alarm reset output 5 Battery 2.8 to 4.5 V + – R88D-UTjjH * CN 1 21 BAT 22 BATGND ALM 31 40 44 X-axis SEN signal ground 8 2 9 4 SEN 10 1 33 GND +A 34 36 –A +B +Z 11 12 X-axis B phase input 13 X-axis B phase input 14 X-axis Z phase input 15 35 19 X-axis Z phase input 16 20 X-axis speed command 17 5 6 X-axis speed cmnd ground 18 Shell DC supply 0V +24 V SENGND t R S T P RESET X-axis feedback ground X-axis A phase input * * RUN X-axis SEN signal output X-axis A phase input TB r * * MC B N Red U R88M-Ujjjjjj R88A-CAUBjjjS R88A-CAUCjjjS White V W M Black Green –B –Z REF AGND FG 24-V output 19 47 +24 VIN 24-V output ground 20 32 ALMCOM I/O Connector 24-V input 1 X-axis CW limit input 2 X-axis CCW limit input X-axis emerg. stop input X-axis origin prox. input 4 6 10 24-V input ground 14 CN2 R88A-CRUBjjjN RE Special-purpose cable R88A-CPUBjjjM1 (for one axis) R88A-CPUBjjjM2 (for two axes) Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver. Note 2. Leave unused signal lines open and do not wire them. Note 3. Connect the terminals and wiring marked by asterisks (*) when using an absolute encoder. Note 4. This wiring diagram is for the X axis only. If the other axis is to be used, connect to the Servo Driver in the same way. Note 5. Be sure to short (in the connector) any unused NC input terminals in the CV500-221/421-E’s I/O connector. Note 6. Use the RUN signal to set whether the Servo can be turned ON/OFF. 6-7 Chapter 6 Appendix 6-2 Encoder Divider Rate for Servo Controllers Encoder output pulses for OMNUC U-Series AC Servo Drivers can be set within a range of 16 to 4,096 pulses/revolution by setting the encoder divider rate. Depending on the Controller’s encoder input maximum response frequency limits, however, the maximum numbers of revolutions are limited as shown in the following table. In this table, the divider rates are shown in the top line above the multipliers. (“MC” indicates CV-500-MC221/421 Motion Control Units, and “NC” indicates C500-NC222-E Position Control Units. H Encoder Divider Rates (Cn-0A) and Maximum Numbers of Rotations 2,048 to 1,366 1,365 to 1,025 4 C500-NC222-E CV500-MC221/ MC421 C200H-MC221 2 1 4 2 1 4,500 4,500 2,196 4,394 4,500 3,294 4,500 1,024 to 819 4 2 1 4,500 4,392 4,500 4096 y Cn-0A > 4096 n n+1 4 2 1 2,490 x n 1,098 x n 2,197 x n Note 1. “n” represents a number from 1 to 256. Note 2. The numbers in this table indicate the maximum number of revolutions (r/min) that can be used in combination with Servo Controllers. Note 3. The upper limit for the maximum number of revolutions is 4,500 r/min. 6-8 Chapter 6 Appendix 6-3 OMNUC U-series Standard Models H Models Not Conforming to Any Standards • Servomotors with Incremental Encoders Specification Straight g shafts h ft without key Standard ( ith t (without brake) With brake Straight g h ft with ith shafts key Standard ( ith t (without brake) Model 1.0 kW R88M-U1K030H 1.5 kW R88M-U1K530H 2.0 kW R88M-U2K030H 3.0 kW R88M-U3K030H 4.0 kW R88M-U4K030H 5.0 kW R88M-U5K030H 1.0 kW R88M-U1K030H-B 1.5 kW R88M-U1K530H-B 2.0 kW R88M-U2K030H-B 3.0 kW R88M-U3K030H-B 4.0 kW R88M-U4K030H-B 5.0 kW R88M-U5K030H-B 1.0 kW R88M-U1K030H-S1 1.5 kW R88M-U1K530H-S1 2.0 kW 3.0 kW 4.0 kW 5.0 kW With brake • Parameter Units 1.0 kW 1.5 kW R88M-U3K030H-S1 R88M-U4K030H-S1 R88M-U5K030H-S1 3.0 kW R88M-U3K030H-BS1 4.0 kW R88M-U4K030H-BS1 Specification Standard ( ith t (without brake) Specification Common to i incremental l and d absolute encoders with connectors at both ends R88M-U5K030H-BS1 Model 3m R88A-CRUB003N 5m R88A-CRUB005N 10 m R88A-CRUB010N 15 m R88A-CRUB015N 20 m R88A-CRUB020N • Power Cables (1.0 to 2.0 kW) Specification For standard motors ( ih (without brake) b k ) with ih connector at one end For motors with brake and d with ith connector t att one end Model 3m R88A-CAUB003S 5m R88A-CAUB005S 10 m R88A-CAUB010S 15 m R88A-CAUB015S 20 m R88A-CAUB020S 3m R88A-CAUB003B 5m R88A-CAUB005B 10 m R88A-CAUB010B 15 m R88A-CAUB015B 20 m R88A-CAUB020B • Power Cables (3.0 to 5.0 kW) Specification For standard motors ( ih (without brake) b k ) with ih connector at one end Model Model 3m R88A-CAUC003S 5m R88A-CAUC005S 10 m R88A-CAUC010S 15 m R88A-CAUC015S 20 m R88A-CAUC020S 3m R88A-CAUC003B 5m R88A-CAUC005B 1.0 kW R88M-U1K030T 1.5 kW R88M-U1K530T 2.0 kW R88M-U2K030T 3.0 kW R88M-U3K030T 10 m R88A-CAUC010B R88M-U4K030T 15 m R88A-CAUC015B 5.0 kW R88M-U5K030T 20 m R88A-CAUC020B 1.0 kW R88M-U1K030T-B 1.5 kW R88M-U1K530T-B 2.0 kW R88M-U2K030T-B 3.0 kW R88M-U3K030T-B 4.0 kW R88M-U4K030T-B 5.0 kW R88M-U5K030T-B 4.0 kW With brake R88A-PR03U R88M-U1K530H-BS1 • Servomotors with Absolute Encoders Straight g shafts h ft without key Mounted type • Encoder Cables R88M-U1K030H-BS1 R88M-U2K030H-BS1 Model R88A-PR02U R88M-U2K030H-S1 2.0 kW 5.0 kW Specification Handy type • Servo Drivers Specification Model Common to analog g and pulse l ttrain i iinputs t 1.0 kW R88D-UT24H 1.5 kW R88D-UT40H Common to incremental and absolute encoders 2.0 kW R88D-UT60H 3.0 kW R88D-UT80H 4.0 kW R88D-UT110H 5.0 kW R88D-UT120H For motors with brake and d with i h connector at one end • Dedicated Control Cables Specification For CV500-MC221 /421 and C200H MC221 C200H-MC221 with connectors t att both ends 1 axis 2 axes Model 1m R88A-CPUB001M1 2m R88A-CPUB002M1 1m R88A-CPUB001M2 2m R88A-CPUB002M2 • General-purpose Control Cables Specification For general-purpose controllers with connector at one end Model 1m R88A-CPUB001S 2m R88A-CPUB002S • Control Cable Connector Specification Half-pitch 50P (Sumitomo 3M) Model R88A-CNU11C 6-9 Chapter 6 Appendix H Models Conforming to EC Directives • Servomotors with Incremental Encoders Specification Straight g shafts h ft with ith key Standard ( ith t (without brake) With brake • Parameter Units Model Handy type R88A-PR02U 1.5 kW R88M-U1K530V-S1 Mounted type R88A-PR03U 2.0 kW R88M-U2K030V-S1 3.0 kW R88M-U3K030V-S1 4.0 kW R88M-U4K030V-S1 5.0 kW R88M-U5K030V-S1 1.0 kW 2.0 kW R88M-U1K030V-BS1 R88M-U1K530V-BS1 3.0 kW R88M-U3K030V-BS1 4.0 kW R88M-U4K030V-BS1 5.0 kW R88M-U5K030V-BS1 Specification With brake • Encoder Cables Specification Common to incremental d absolute b l t encoders d and with connectors at both ends R88M-U2K030V-BS1 • Servomotors with Absolute Encoders Standard ( ith t (without brake) Model R88M-U1K030V-S1 1.5 kW Straight g h ft with ith shafts key Specification 1.0 kW Model 1.0 kW R88M-U1K030X-S1 1.5 kW R88M-U1K530X-S1 2.0 kW R88M-U2K030X-S1 3.0 kW R88M-U3K030X-S1 4.0 kW R88M-U4K030X-S1 5.0 kW R88M-U5K030X-S1 1.0 kW R88M-U1K030X-BS1 1.5 kW R88M-U1K530X-BS1 2.0 kW R88M-U2K030X-BS1 3.0 kW R88M-U3K030X-BS1 4.0 kW R88M-U4K030X-BS1 5.0 kW R88M-U5K030X-BS1 Common to analog g and pulse l train i iinputs Common to incremental and absolute encoders R88D-UT24V 1.5 kW R88D-UT40V 2.0 kW R88D-UT60V 3.0 kW R88D-UT80V 4.0 kW R88D-UT110V For motors with brake and d with ith connector t att one end Specification Common to analog g and pulse l train i iinputs Common to incremental and absolute encoders Note Model 1.0 kW 1.5 kW R88D-UT24V-RG R88D-UT40V-RG 2.0 kW R88D-UT60V-RG 3.0 kW R88D-UT80V-RG For the R88D-UTjV-RG and R88D-UT110V, be sure to install External Regenerative Resistors that correspond to the amount of regenerative energy. • External Regenerative Resistor Specification 70 W 6-10 R88A-CRUB005N 10 m R88A-CRUB010N 15 m R88A-CRUB015N 20 m R88A-CRUB020N Model 3m R88A-CAUB003S 5m R88A-CAUB005S 10 m R88A-CAUB010S 15 m R88A-CAUB015S 20 m R88A-CAUB020S 3m R88A-CAUB003B 5m R88A-CAUB005B 10 m R88A-CAUB010B 15 m R88A-CAUB015B 20 m R88A-CAUB020B • Power Cables (3.0 to 5.0 kW) Specification For standard motors ( ith t brake) (without b k ) with ith connector at one end For motors with brake and d with ith connector t att one end 5.0 kW • Servo Drivers (Requiring External Regenerative Resistors) R88A-CRUB003N 5m Specification For standard motors ( ith t brake) (without b k ) with ith connector at one end Model 1.0 kW 3m • Power Cables (1.0 to 2.0 kW) • Servo Drivers Specification Model Model 3m R88A-CAUC003S 5m R88A-CAUC005S 10 m R88A-CAUC010S 15 m R88A-CAUC015S 20 m R88A-CAUC020S 3m R88A-CAUC003B 5m R88A-CAUC005B 10 m R88A-CAUC010B 15 m R88A-CAUC015B 20 m R88A-CAUC020B • Dedicated Control Cables Specification For CV500 MC221/421 CV500-MC221/421 and C200H-MC221 with connectors at b th ends both d 1 axis 2 axes Model 1m R88A-CPUB001M1 2m R88A-CPUB002M1 1m R88A-CPUB001M2 2m R88A-CPUB002M2 • General-purpose Control Cables Specification For general-purpose controllers with connector at one end Model 1m R88A-CPUB001S 2m R88A-CPUB002S • Control Cable Connector Model R88A-RR22047S Specification Half-pitch 50P (Sumitomo 3M) Model R88A-CNU11C Chapter 6 Appendix 6-4 Combinations of Servo Drivers and Servomotors H Models Not Conforming to Any Standards Servo Drivers R88D-UT24H R88D-UT40H R88D-UT60H R88D-UT80H R88D-UT110H R88D-UT120H Servomotors With Incremental Encoders R88M-U1K030H-j R88M-U1K530H-j R88M-U2K030H-j R88M-U3K030H-j R88M-U4K030H-j R88M-U5K030H-j With Absolute Encoders R88M-U1K030T-j R88M-U1K530T-j R88M-U2K030T-j R88M-U3K030T-j R88M-U4K030T-j R88M-U5K030T-j Motor Capacity p y 1 kW 1.5 kW 2 kW 3 kW 4 kW 5 kW H Models Conforming to EC Directives Servo Drivers R88D-UT24V-j R88D-UT40V-j R88D-UT60V-j R88D-UT80V-j R88D-UT110V Servomotors With Incremental Encoders R88M-U1K030V-jS1 R88M-U1K530V-jS1 R88M-U2K030V-jS1 R88M-U3K030V-jS1 R88M-U4K030V-jS1 R88M-U5K030V-jS1 With Absolute Encoders R88M-U1K030X-jS1 R88M-U1K530X-jS1 R88M-U2K030X-jS1 R88M-U3K030X-jS1 R88M-U4K030X-jS1 R88M-U5K030X-jS1 Motor Capacity p y 1 kW 1.5 kW 2 kW 3 kW 4 kW 5 kW Note The default setting of the R88D-UT110V is 4 kW (motor selection: “167”). When using a 5-kW motor, change the motor selection setting to “168.” 6-11 ">
Advertisement
Key features
- High performance
- Fast response times
- Up to 5 kW output capacity
- Auto-tuning function
- Monitor function
- Jog operation
- Electronic gear function (position control)
- Encoder resolution function
- Software start function
- Brake interlock output
Frequently asked questions
The manual highlights crucial user parameters such as the control mode, speed, acceleration, and deceleration settings. Understanding these parameters allows for proper system operation and optimization.
The auto-tuning feature automatically adjusts the gain to match the load, making setup easier. The manual details the steps involved in using auto-tuning.
The OMNUC U series offers 12 control modes, including speed control, position control, and torque control. Each mode suits specific application needs, and the manual explains how to select the appropriate mode.
The manual outlines the process for switching between control modes, allowing for flexibility in adjusting the driver’s behavior based on the application.
The manual provides information on regenerative energy absorption and the models that require external regenerative resistors. It also explains the function of these resistors and how they help manage energy dissipation during operation.