Below you will find brief information for Hampton fixture Hampton 3200 AN/BR. This is a fixture that can be used to install a variety of lighting options in your home. Some of the key features of this fixture include its mounting strap, nipple, canopy, and shade. The fixture can be lamped accordingly and has a decorative finial that can be added to the end of the nipple.
3200
assembly instructions
Family: Hampton
Item No. 3200 AN/BR
Drawing 1 - Fixture Assembly
start he re
1. Find a clear area in which you can work.
1
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
.
*** The construction of this fixture will be accomplished by first assembling the
main body structure, installing the mounting hardware to the junction box,
mounting the fixture to the ceiling and then installing the shade.
Drawing 2 - Fixture Assembly
1. Attach acrylic lens assembly (1) by threading coupler (2) onto end of lower upright
stems (3) - see Drawings 1 and 2.
3
2
1
3
1. Fasten mounting strap (B) to outlet box (A) with the original box screws (C) - see
Drawing 3.
2. Thread nipple (D) into mounting strap (B) approximately 3/8”.
4
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 3 - Mounting Instructions
4
A
B
C
D
E
Make electrical connections from supply wire to fixture lead wires. Refer to instruction
sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.
Then refer back to this page to continue installation of this fixture.
5
1. Slip canopy (E) over nipple (D) and up against ceiling - see Drawing 3.
6
1. Fixture can now be lamped accordingly.
2. Thread decorative finial (F) onto end of nipple (D).
2. Slip shade (4) onto acrylic assembly (1) - see Drawing 2.
F
HINKLEY LIGHTING
33000 Pin Oak Parkway Avon Lake, OH 44012
800.446.5539 / 440.653.5500
hinkleylighting.com
9.31.09
grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 1 - Flush Mount
supply wire
A
C
Indoor Fixtures
E
1
2
twist-on
connectors
D
B
fixture leads
Drawing 2 - Chain Hung
supply wire
A
C
E
twist-on
connectors
1
B
D
E
wiring instructions
2
fixture leads
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all
electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a
fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all
electrical connections.
Drawing 3 - Post-Mount
grounding instructions
supply wire
A
C
E
twist-on
connectors
E
B
D
fixture leads
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1)
with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power
supply ground with appropriately sized twist-on connector inside post. Cover open
end of connector with silicone sealant to form a watertight seal - see Drawing 3.
HINKLEY LIGHTING
33000 Pin Oak Parkway Avon Lake, OH 44012
800.446.5539 / 440.653.5500
hinkleylighting.com
I.S. 18
I.S. 18 wiring
Fasten the mounting strap (B) to the outlet box (A) with the original box screws (C) - see Drawing 3.
How do I attach the acrylic lens assembly?
Attach acrylic lens assembly (1) by threading coupler (2) onto end of lower upright stems (3) - see Drawings 1 and 2.
How do I connect the supply wire to the fixture lead wires?
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.
How do I slip the canopy over the nipple?
Slip canopy (E) over nipple (D) and up against ceiling - see Drawing 3.
How do I thread the decorative finial onto the end of the nipple?
Thread decorative finial (F) onto end of nipple (D).