Emerson Series 3000 Satellite Radio User Manual

Product Data Sheet
PS-00291, Rev. B
May 2007
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Micro Motion® Series 3000 electronics combine transmitter functions and
PLC capabilities in one instrument. Series 3000 models feature MVD™
technology, providing high-speed DSP capabilities and a broad range of
specialty applications.
Large operator interface for easy setup & control
•
128 x 128 pixel display enhances view of process
•
Easy to read menus and advanced help system
2400S
Compact integral
transmitter
Transmitter and discrete control from a single instrument
•
Functions as an advanced process transmitter or as a discrete
batch controller, with 8 I/O channels for maximum adaptability
•
HART® and Modbus® support expand communications options
Wide variety of applications
•
Concentration & net flow measurement
•
Custody transfer with batch control
•
Patented meter verification application
1700
2700
Versatile
field-mount
transmitter
1500
2500
Compact
control-room
transmitter
3300
3350
Frequency-input
discrete controller
3500
3700
Integrated control
and measurement
platform
Micro Motion transmitters and controllers
Micro Motion transmitters and controllers fit a wide variety of application needs. The table below can help
determine which Micro Motion products are right for your process. For more detailed product information,
consult the appropriate Product Data Sheet or contact your local Micro Motion representative.
1500
1700
2400S
2500
Output variables
Mass / volume flow
Net mass / volume flow
Temperature
Density
Concentration
Local display
2-line
Multi-line
Outputs
4–20 mA
10 kHz pulse
Discrete
HART®
Modbus®
FOUNDATION fieldbus™
PROFIBUS-PA
PROFIBUS-DP
DeviceNet®
Inputs
10 kHz pulse
Discrete
4-wire Coriolis sensor
9-wire Coriolis sensor
Mounting
Integral – Field
Remote – Field
Remote – Control room
Application type
Batch controller
Custody transfer
Filling & dosing
Meter verification
Hazardous approvals
C1D1
C1D2
Zone 1
Zone 2
2
Micro Motion® Series 3000 Transmitters and Discrete Controllers
2700
3300
3350
3500
3700
Series 3000 transmitters and discrete controllers
MVD technology. MVD technology makes your
Micro Motion meter work smarter. Front-end digital
processing dramatically reduces signal noise and
gives you faster response time compared to analog
devices.
Only MVD technology allows you to:
•
Measure multiple variables
•
Install easily with a standard 4-wire signal cable
•
Identify and resolve problems easily with built-in
smart diagnostics
•
Choose transmitter capabilities based on your
application’s needs
•
Upgrade transmitter functionality as needed
Series 3000 transmitters and controllers with MVD
technology. Model 3500 and 3700 transmitters
deliver process measurement and discrete control
based on direct input from a Micro Motion Coriolis
meter. Model 3300 and 3350 controllers provide
discrete control based on a frequency input from a
remote transmitter. Series 3000 models are
available with specialty applications, such as batch
control, enhanced density measurement, petroleum
measurement, custody transfer, and meter
verification.
Configuration, operation, and maintenance are all
accomplished using the innovative Series 3000 user
interface. The interface features a large, easy-touse backlit display with big, tactile-feedback push
buttons. Other user interfaces (such as hand-held
communication devices) are not required, but can
be used. Modbus and HART communication allow
configuration devices such as ProLink II, AMS, and
HART Communicators to be used with the
Series 3000, and the Series 3000 can be integrated
into a PlantWeb network.
Contents
Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model 3100 accessory . . . . . . . . . . . . . . . . . . . . 10
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model 3500/3700 liquid flow performance . . . . . 10
Interface/display. . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical connections . . . . . . . . . . . . . . . . . . . . . . 5
Model 3500/3700 density
performance (liquid only). . . . . . . . . . . . . . . . . . . 11
Input signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Model 3500/3700 gas flow performance . . . . . . . 11
Output signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Environmental specifications . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ordering information . . . . . . . . . . . . . . . . . . . . . . 16
Hazardous area classifications . . . . . . . . . . . . . . . 9
Micro Motion® Series 3000 Transmitters and Discrete Controllers
3
Housings
Rack-mount
19-inch (486.2 mm) rack-mount housing meets DIN standard 41494 and IEC 297-3
Front panel is rated IP40
Panel-mount
Front panel with bezel is rated NEMA 4X (IP65)
Field-mount
Compartment with threaded cover contains electronics
Terminal compartment contains:
• Non-intrinsically safe compartment with input/output and power supply terminals
• Intrinsically safe compartment with interface/display, sensor terminals (Model 3700 only), and
optional input and output terminals
Mounting bracket and interface/display rotate to allow mounting in four different orientations
Rated NEMA 4X (IP67)
Applications
Process monitor/totalizer
Process monitoring and totalizing for multiple variables, including mass flow, volume flow, density,
and temperature.
Discrete batch control
•
•
•
•
Meter verification
Provides in-situ assessment of a Micro Motion Coriolis meter, determining whether the meter has
been affected by erosion, corrosion, or other influences affecting meter calibration. No secondary
references are required to perform this operation.
Enhanced density
Enhanced density measurement for a number of applications, including:
• %HFCS, °Brix, °Plato, °Balling,
• °Baumé at SG60/60
• Density at reference temperature
• Specific gravity
• Concentration derived from reference density
• Concentration derived from specific gravity
Custody transfer
•
•
•
•
•
•
Configuration of up to six preset batch recipes
One-stage or two-stage batch control
End-of-batch warning and batch-overrun alarms
Configuration by quantity or by percent of target for primary valve closure, secondary valve
opening and closure, end warning, and batch overrun
• Configuration for target lockout, or for target adjustment during batch operation
• Automatic overshoot compensation
Physical and software security
Security-alarm posting
Mass or volume totalizer that can be configured by the user
Custom formatting of receipt tickets
Audit trail of configuration changes
Multidrop printing capability
Petroleum measurement (API) Provides API process variables, such as API volume flow and API average density.
4
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Interface/display
Display
Models 3300 and 3500
Models 3350 and 3700
Keypad membrane switch
Backlit LCD, 128 × 128 pixel, bit map
Adjustable contrast
Non-glare, chemical-resistant acrylic lens
Backlit LCD, 128 × 128 pixel, bit map
Adjustable contrast
Non-glare tempered glass lens
Suitable for hazardous area installation
Large push buttons with tactile feedback
Software-defined function keys
Chemical-resistant polyester
Electrical connections
Input and output connections
Rack-mount
Type D connectors per DIN standard 41612 (IEC 603-2)
Available as solder tails (standard) or screw terminals (optional)
Screw terminals accept 24 AWG (0.25 mm2) to 16 AWG (1.5 mm2) wires
Panel-mount
Screw terminals (standard) or I/O cable with remote DIN rail-mount screw
terminals (optional)
Remote terminals attach to any of four rail types. I/O cable is available in lengths of 2, 5, and 10
feet (0.6, 1.5, and 3 meters)
Screw terminals accept 24 AWG (0.25 mm2) to 16 AWG (1.5 mm2) wires
Field-mount
Two color-coded wiring compartments:
•
Compartment with intrinsically safe terminals has two 3/4-inch NPT or M20 × 1.5 conduit
openings
•
Compartment with non-intrinsically safe terminals has three 3/4-inch NPT or M20 × 1.5
conduit openings
Screw terminals accept 22 AWG (0.34 mm2) to 16 AWG (1.5 mm2) wires
Power connection
Rack-mount
Screw terminals are fixed to rack chassis
Ground makes first and breaks last
Screw terminals accept 18 AWG (0.75 mm2) to 14 AWG (2.5 mm2) wires
Panel-mount
Screw terminals accept 18 AWG (0.75 mm2) to 14 AWG (2.5 mm2) wires
Field-mount
Screw terminals accept 18 AWG (0.75 mm2) to 12 AWG (4.0 mm2) wires
Micro Motion® Series 3000 Transmitters and Discrete Controllers
5
Input signals
Non-intrinsically safe input signals
One 2-wire
Frequency range
frequency/pulse input
Minimum pulse width
Power
Voltage
Current
Two discrete
momentary inputs
Pulse width
Voltage
0–20,000 Hz
25 μ-sec
Sourcing or sinking
0–0.8 VDC low state
3–30 VDC high state
Nominal 5 mA pull-up
0.15 sec minimum
0–0.8 VDC low state
3–30 VDC high state
Dry contacts
Intrinsically safe input signals
One 4-wire Coriolis sensor signal input with ground
Output signals
Non-intrinsically safe output signals
Two active
Isolated to ±50 VDC from all other outputs and earth ground
4–20 mA outputs
Maximum load limit of 1000 Ohms
Output is linear with process from 3.8 to 20.5 mA per NAMUR NE43 (June 1994)
Three discrete outputs
One 2-wire
frequency/pulse output
Configurable for the application
Polarity
Power
Voltage
Current
Active high or active low, software selectable
Internal pull-up to 24 V
24 VDC nominal
Sourcing at 5.6 mA when Vout = 3 VDC
Sinking up to 500 mA at 30 VDC maximum
Scalable to 10,000 Hz
Output is linear with flow rate to 12,500 Hz
Pulse width
50% duty cycle above the crossover frequency (1)
Configurable between 0.543 ms and 277 ms
Polarity
Active high or active low, software selectable
Power
Active or passive, software selectable
Voltage
24 VDC nominal, active
30 VDC applied maximum, passive
Current
Sourcing at 10 mA at 3 VDC, active
Sinking at 500 mA, active or passive
(1) The crossover frequency depends on the configured value of the pulse width. At the minimum pulse width value of 0.543 ms, the
crossover frequency is 922 Hz. At the maximum pulse width value of 277 ms, the crossover frequency is 1.8 Hz.
6
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Output signals continued
Fault indication
When a fault is detected, outputs go to configured states. User can select upscale, downscale, internal zero, or none. Milliamp
outputs conform to NAMUR NE43 (June 1994).
Upscale
Milliamp
Frequency
21 to 24 mA, user configurable
15,000 Hz
Downscale
Milliamp
Frequency
1 to 3.6 mA, user configurable
0 Hz
Internal zero
Drives the mA and frequency outputs for process variables to zero values
None
Ignores fault conditions
Digital communications
RS-485 port
One pair of terminals supports SP (service port) mode or RS-485 mode. On device power-up, the
user has 10 seconds to connect in SP mode. After 10 seconds, the terminals switch to RS-485
mode. The communication parameters in SP mode are:
Data rate
38,400 baud
Parity
No parity
Stop bit
One stop bit
Address
111
In RS-485 mode, the Series 3000 can communicate via Modbus RTU, Modbus ASCII, or HART (1)
protocols. The communication parameters are configurable with ProLink II software, Modbus, or
the display. The shipped default parameters are:
Data rate
9600 baud
Parity
Odd
Stop bit
One stop bit
The RS-485 port can also be configured as a printer port (see below).
HART Bell 202 (1)
The HART Bell 202 signal is superimposed on the primary mA output, and is available for host
system interface. The HART Bell 202 communication parameters are:
Frequency
1.2 and 2.2 KHz
Amplitude
0.8 mA peak-to-peak
Data rate
1200 baud
Resistance
Loop requires 250 to 600 Ohms resistance
Printer port
The RS-485 port can be configured as a printer port. When the RS-485 port is
configured as a printer port, it cannot be used for any other function.
Requires external RS-232 adapter (not included)
Bidirectional with Epson printer; send only with all other printers and when using a multidrop
configuration
(1) Using HART, it is possible to configure basic transmitter functionality, and read/write batch setpoints and totals. Series 3000 batch
applications or enhanced density applications cannot be configured using HART. Using Modbus, all transmitter functionality, batch
commands, and batch applications can be controlled.
Micro Motion® Series 3000 Transmitters and Discrete Controllers
7
Environmental specifications
EMI effects
All Series 3000 devices Meet EMC directive 89/336/EEC per EN 61326 Industrial, and all Series
3000 devices conform to NAMUR NE21 (June 1997).
Ambient temperature effect
On analog outputs
±0.005% of span per °C
Ambient temperature limits (1)
Operating
Storage
–4 to +140 °F
–40 to +158 °F
Temperature accuracy
Models 3500 and 3700
±1.0 °C ±0.5% of reading in °C
Temperature repeatability
Models 3500 and 3700
±0.2 °C
Humidity limits
5 to 95% relative humidity, non-condensing at 140 °F (60 °C)
Vibration limits
Per IEC 68-2-6, endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1.0 g
–20 to +60 °C
–40 to +70 °C
(1) If exposed to direct sunlight, the ambient temperature can be expected to rise by an additional 50 °F (10 °C).
Power supply
AC power supply
Model 3300
Models 3350, 3500,
and 3700
DC power supply
Model 3300
Models 3350, 3500,
and 3700
8
85 to 265 VAC
50/60 Hz, 15 VA
0.25 A maximum at 85 VAC, 0.12 A maximum at 265 VAC
IEC 127-3/4 fuse, 0.63 A time-delay
Complies with European low-voltage directive 2006/95/EC per IEC 61010-1
Installation (Overvoltage) Category II, Pollution Degree 2
85 to 265 VAC
50/60 Hz, 30 VA
0.33 A maximum at 85 VAC, 0.15 A maximum at 265 VAC
IEC 127-3/4 fuse, 0.63 A time-delay
Complies with European low-voltage directive 2006/95/EC per IEC 61010-1
Installation (Overvoltage) Category II, Pollution Degree 2
18 to 30 VDC
7 watts typical, 14 watts maximum
IEC 127-3/4 fuse, 1.6 A time-delay
18 to 30 VDC
18 watts typical, 25 watts maximum
IEC 127-3/4 fuse, 1.6 A time-delay
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Hazardous area classifications
UL is a U.S.A. approvals agency. CSA is a Canadian approvals agency that provides approvals accepted in both the U.S.A.
(C-US) and Canada. ATEX is a European directive.
UL and CSA
ATEX
Model 3300
Class I, Div. 2, Groups A, B, C, and D when installed in a suitable
enclosure
Model 3350
Class I, Div. 2, Groups A, B, C, and D
Model 3500
Class I, Div. 2, Groups A, B, C, and D when installed in a suitable
enclosure
Provides non-incendive sensor outputs for use in Class I, Div. 2,
Groups A, B, C, and D, or intrinsically safe sensor outputs for use
in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F,
and G
Model 3700
Class I, Div. 2, Groups A, B, C, and D
Provides non-incendive sensor outputs for use in Class I, Div. 2,
Groups A, B, C, and D, or intrinsically safe sensor outputs for use
in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F,
and G
Model 3350
ATEX Zone 1
CE 0575
Model 3500
Safe area only. Can be connected to a sensor in ATEX Zone 1
area.
CE 0575
Model 3700
II 2G EEx de [ib] IIB/IIC T4
II (2)G [EEx ib] IIB/IIC
ATEX Zone 1
CE 0575
II 2G EEx de [ib] IIB/IIC T4
Micro Motion® Series 3000 Transmitters and Discrete Controllers
9
Model 3100 accessory
Relays module
Three relays
Solid state, SPST
Rated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 A
Energized by discrete outputs
NEMA 4X (IP65) enclosure (optional)
UL and CSA approvals
Class I, Div. 2, Groups A, B, C, and D
ATEX approvals
Suitable for installation in Zone 2, when properly installed in a suitable enclosure, complying with
ATEX Directive (94/9/EC) for Group II, Category 3G, according to CENELEC standard EN 50021
(1998) and marked as:
EEx n V II T4
KEMA 97 ATEX4940X
Ambient temperature –20 to +60 °C (–4 to +140 °F)
Additional installation-specific requirements are described in detail in the Series 3000 instruction
manual.
Model 3500/3700 liquid flow performance
Sensor model
Mass flow accuracy (1)(2)
ELITE®
F-Series
H-Series
T-Series
R-Series
±0.05% of rate
±0.10% of rate
±0.10% of rate
±0.15% of rate
±0.50% of rate
Volume flow accuracy (1) (2)
ELITE
F-Series
H-Series
T-Series
R-Series
±0.05% of rate
±0.15% of rate
±0.15% of rate
±0.25% of rate
±0.50% of rate
Repeatability (2)
ELITE
F-Series
H-Series
T-Series
R-Series
±0.025% of rate
±0.05% of rate
±0.05% of rate
±0.05% of rate
±0.25% of rate
(1) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis.
(2) For the details of flow accuracy and repeatability specifications, refer to the product data sheet for each sensor family.
10
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Model 3500/3700 density performance (liquid only)
Accuracy (1)
Repeatability (1)
Sensor model
g/cm3
kg/m3
ELITE
F-Series
H-Series
±0.0002
±0.001
±0.001
±0.2
±1.0
±1.0
T-Series
R-Series
±0.002
Not rated for density
±2.0
ELITE
F-Series
H-Series
T-Series
R-Series
±0.0001
±0.0005
±0.0005
±0.0005
Not rated for density
±0.1
±0.5
±0.5
±0.5
(1) For the details of the density accuracy and repeatability specifications, refer to the product data sheet for each sensor family.
Model 3500/3700 gas flow performance
Sensor model
Mass flow accuracy
ELITE®
F-Series
H-Series
T-Series
R-Series
±0.35% of rate
±0.50% of rate
±0.50% of rate
±0.65% of rate
±0.75% of rate
Repeatability
ELITE
F-Series
H-Series
T-Series
R-Series
±0.20% of rate
±0.25% of rate
±0.25% of rate
±0.25% of rate
±0.50% of rate
Weight
Models 3300 and 3500
Maximum 3.5 lb (1.6 kg), excluding prepared cables
Models 3350 and 3700
19 lb (8.6 kg)
Micro Motion® Series 3000 Transmitters and Discrete Controllers
11
Dimensions
Rack-mount Model 3300/3500
Dimensions in
1 U = 1 HE = 1.750 inches (44.45 mm)
1 HP = 1 TE = 0.200 inches (5.08 mm)
inches
(mm)
25 HP (25 TE)
5.0 (127)
4× M2.5 × 11
3U
(3 HE)
5 1/16
(128.5)
4 13/16
(122.5)
28 HP (28 TE)
5 9/16 (142.2)
19″ (486.2 mm) subrack conforms to
DIN 41494 Part 5, and IEC 297-3
Not included as part of Model 3300/3500
Screw terminal connector (optional)
Rear rail for mounting connectors that
conform to DIN 41612 and IEC 603-2
Not included as part of Model 3300/3500
Intrinsic safety shield
(Model 3500 only)
Approvals tag
1
(25.4)
6 11/16
(169.9)
7 11/32
(186.7)
7 29/32
(200.6)
8 33/64
(216.2)
12
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Dimensions continued
Panel-mount Model 3300/3500 with screw-type connectors
Dimensions in
inches
(mm)
6 1/2
(165)
8 1/2
(216)
Panel
7 3/4
(197)
Frame
Bezel
4 1/2
(114)
6
(152)
6 11/16
(170)
Approvals tag
6
(152)
Intrinsic safety barrier
(Model 3500 only)
1/2
(12)
Micro Motion® Series 3000 Transmitters and Discrete Controllers
13
Dimensions continued
Panel-mount Model 3300/3500 with optional I/O cable
Dimensions in
inches
(mm)
6 1/2
(165)
Panel
8 3/4
(222)
Frame
Bezel
5 5/16
(135)
6
(152)
6 11/16
(170)
Approvals tag
Minimum 4 1/4″
(108 mm) bend radius
6
(152)
1/2
(12)
3 3/64
(77)
9
(229)
2 31/64
(63)
2 37/64
(66)
14
2 1/4
(57)
DIN-rail-mount
screw terminals detail
2 15/64
(57)
2 19/64
(59)
DIN rail type TS 15
DIN rail type TS 32
DIN rail type TS 35 × 7.5
DIN rail type TS 35 × 15
Micro Motion® Series 3000 Transmitters and Discrete Controllers
3 17/32
(90)
Dimensions continued
Field-mount Model 3350/3700
inches
(mm)
Dimensions in
11
(279)
5 1/16″ (129 mm)
Minimum clearance for removal
of circuit boards
12
(305)
4× ø 5/16
(9)
9 3/16
(234)
2 13/16
(71)
Approvals tag
4
(102)
11 5/16
(288)
6 1/8
(156)
Mounting bracket can
be rotated 90°
3 5/8
(92)
Display/cover can be
rotated 90° or 180°
6
(152)
8 11/16
(221)
15 1/2
(394)
4× M8 × 16 bolts are included
for attaching the mounting bracket to
the Model 3350 or 3700 transmitter
1 7/8
(48)
2× 2 13/16
(71)
2× 15/16
(24)
Case ground
5× 3/4–14 NPT
or M20 × 1.5
female conduit opening
10 3/8
(264)
Conduit openings view
7 1/2
(191)
5 3/4
(147)
Mounting surface
Micro Motion® Series 3000 Transmitters and Discrete Controllers
15
Ordering information — Model 3300
Model
Product description
3300
Micro Motion Coriolis Discrete Controller; remote rack/panel-mount
Code
Mounting options
R
DIN rack
P
Panel-mount
Code
Power supply options
1
85 to 265 VAC
2
18 to 30 VDC (recommended for 24 VDC users)
Code
Communication gateway module
A
No communication gateway module
Code
Additional hardware modules
0
No additional hardware modules
1 (1)
Weights & Measures Custody Transfer (all other than OIML)
2
Weights & Measures Custody Transfer (OIML)
Code
Sensor interface
0
No sensor interface
Code
Terminals
A
Solder pins (use with mounting code R only)
B
Screw terminals
C
Prepared cables; 2 foot (0.6 m) length (use with mounting code P only)
D
Prepared cables; 5 foot (1.5 m) length (use with mounting code P only)
E
Prepared cables; 10 foot (3 m) length (use with mounting code P only)
Code
Relays and housings
1
No relays and housing
Code
Approvals
M
Micro Motion standard (no approval)
U
UL
C
CSA (Canada only)
A
CSA C-US (U.S.A. and Canada)
Q (2)
General purpose with CMC (China only)
Continued on next page
(1) Control Application code must be code D (Discrete Batch Controller).
(2) Available with Chinese (M) language option only.
16
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Ordering information — Model 3300 continued
Code
Language
A
English local display
Danish quick reference guide
D
English local display
Dutch quick reference guide
English manual
E
English local display
English quick reference guide
English manual
F
French local display
French quick reference guide
French manual
G
German local display
German quick reference guide
German manual
H
English local display
Finnish quick reference guide
English manual
I
English local display
Italian quick reference guide
English manual
J
Japanese local display
Japanese quick reference guide
English manual
M
English local display
Chinese quick reference guide
English manual
N
English local display
Norwegian quick reference guide
English manual
O
English local display
Polish quick reference guide
English manual
P
English local display
Portuguese quick reference guide
English manual
S
English local display
Spanish quick reference guide
Spanish manual
W
English local display
Swedish quick reference guide
English manual
B
English local display
Hungarian CE requirements document
English manual and quick reference guide
C
English local display
Czech CE requirements document
English manual and quick reference guide
K
English local display
Slovak CE requirements document
English manual and quick reference guide
L
English local display
Latvian CE requirements document
English manual and quick reference guide
T
English local display
Estonian CE requirements document
English manual and quick reference guide
U
English local display
Greek CE requirements document
English manual and quick reference guide
V
English local display
Lithuanian CE requirements document
English manual and quick reference guide
Y
English local display
Slovenian CE requirements document
English manual and quick reference guide
Code
Control application software
Z
Process monitor/totalizer (standard)
D
Discrete batch controller
Code
Measurement application software
Z
No measurement application software
Code
Specialty applications
Z
No specialty applications
X
ETO application
Typical model number:
English manual
3300 R 1 A 0 0 A 1 U E D Z Z
Micro Motion® Series 3000 Transmitters and Discrete Controllers
17
Ordering information — Model 3350
Model
Product description
3350
Micro Motion Coriolis Discrete Controller; remote field-mount
Code
Mounting options
A
Field-mount
Code
Power supply options
1
85 to 265 VAC
2
18 to 30 VDC (recommended for 24 VDC users)
Code
Communication gateway module
A
No communication gateway module
Code
Additional hardware modules
0
No additional hardware modules
1 (1)
Weights & Measures Custody Transfer (all other than OIML)
2
Weights & Measures Custody Transfer (OIML)
Code
Sensor interface
0
No sensor interface
Code
Conduit connections
A
M20 without glands
B
M20 with three increased safety glands
C
M20 with five increased safety glands
D
3/4-inch NPT without conduit seals
Code
Approvals
M
Micro Motion standard (no approval)
U
UL
C
CSA (Canada only)
A
CSA C-US (U.S.A. and Canada)
Z
ATEX — Zone 1 Equipment Category 2
P (2)
NEPSI — Safe area
Continued on next page
(1) Control Application code must be code D (Discrete Batch Controller).
(2) Available only with language option M (Chinese).
18
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Ordering information — Model 3350 continued
Code
Language
A
English local display
Danish quick reference guide
D
English local display
Dutch quick reference guide
English manual
E
English local display
English quick reference guide
English manual
F
French local display
French quick reference guide
French manual
G
German local display
German quick reference guide
German manual
H
English local display
Finnish quick reference guide
English manual
I
English local display
Italian quick reference guide
English manual
J
Japanese local display
Japanese quick reference guide
English manual
M
English local display
Chinese quick reference guide
English manual
N
English local display
Norwegian quick reference guide
English manual
O
English local display
Polish quick reference guide
English manual
P
English local display
Portuguese quick reference guide
English manual
S
English local display
Spanish quick reference guide
Spanish manual
W
English local display
Swedish quick reference guide
English manual
B
English local display
Hungarian CE requirements document
English manual and quick reference guide
C
English local display
Czech CE requirements document
English manual and quick reference guide
K
English local display
Slovak CE requirements document
English manual and quick reference guide
L
English local display
Latvian CE requirements document
English manual and quick reference guide
T
English local display
Estonian CE requirements document
English manual and quick reference guide
U
English local display
Greek CE requirements document
English manual and quick reference guide
V
English local display
Lithuanian CE requirements document
English manual and quick reference guide
Y
English local display
Slovenian CE requirements document
English manual and quick reference guide
Code
Control application software
Z
Process monitor/totalizer (standard)
D
Discrete batch controller
Code
Measurement application software
Z
No measurement application software
Code
Specialty applications
Z
No specialty applications
X
ETO application
Typical model number:
English manual
3350 A 1 0 0 A U E D Z Z
Micro Motion® Series 3000 Transmitters and Discrete Controllers
19
Ordering information — Model 3500
Model
Product description
3500
Micro Motion Coriolis multivariable transmitter and discrete controller; remote rack/panel-mount
Code
Mounting options
R
DIN rack
P
Panel-mount
Code
Power supply options
1
85 to 265 VAC
2
18 to 30 VDC (recommended for 24 VDC users)
Code
Remote core processor
Sensor interface code 5
A
None
Sensor interface code 6 (remote core processor)
B
1/2″–NPT remote core processor — no gland
E
M20 remote core processor — no gland
F
Remote core processor — brass/nickel cable gland
G
Remote core processor — stainless steel cable gland
Code
Additional hardware modules
0
No additional hardware modules
1 (1)
Weights & Measures Custody Transfer (all other than OIML)
2
Weights & Measures Custody Transfer (OIML)
Code
Sensor interface
5
4-wire interface to sensors with core processors
6
4-wire remote mount transmitter with 9-wire remote core processor to sensors with junction box
Code
Terminals
B
Screw terminals
C
Prepared cables; 2 foot (0.6 m) length (use with mounting code P only)
D
Prepared cables; 5 foot (1.5 m) length (use with mounting code P only)
E
Prepared cables; 10 foot (3 m) length (use with mounting code P only)
Code
Relays and housings
1
No relays and housing
Code
Approvals
M
Micro Motion standard (no approval)
U
UL
C
CSA (Canada only)
A
CSA C-US (U.S.A. and Canada)
B
P
ATEX — Safe area with IS sensor outputs
(2)
NEPSI — Safe area
Continued on next page
(1) Control Application code must be code D (Discrete Batch Controller).
(2) Available with Chinese (M) language option only.
20
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Ordering information — Model 3500 continued
Code
Language
A
English local display
Danish quick reference guide
D
English local display
Dutch quick reference guide
English manual
E
English local display
English quick reference guide
English manual
F
French local display
French quick reference guide
French manual
G
German local display
German quick reference guide
German manual
H
English local display
Finnish quick reference guide
English manual
I
English local display
Italian quick reference guide
English manual
M
English local display
Chinese quick reference guide
English manual
N
English local display
Norwegian quick reference guide
English manual
O
English local display
Polish quick reference guide
English manual
P
English local display
Portuguese quick reference guide
English manual
S
English local display
Spanish quick reference guide
Spanish manual
W
English local display
Swedish quick reference guide
English manual
B
English local display
Hungarian CE requirements document
English manual and quick reference guide
C
English local display
Czech CE requirements document
English manual and quick reference guide
K
English local display
Slovak CE requirements document
English manual and quick reference guide
L
English local display
Latvian CE requirements document
English manual and quick reference guide
T
English local display
Estonian CE requirements document
English manual and quick reference guide
U
English local display
Greek CE requirements document
English manual and quick reference guide
V
English local display
Lithuanian CE requirements document
English manual and quick reference guide
Slovenian CE requirements document
English manual and quick reference guide
English manual
Y
English local display
Code
Control application software
Z
Process monitor/totalizer (standard)
C (1)
Process monitor/totalizer; with meter verification, structural integrity method
D
Discrete batch controller
E
(1)
Discrete batch controller; with meter verification, structural integrity method
Code
Measurement application software
Z
No measurement application software
G
Enhanced density
B
Enhanced density with predefined algorithms for food and beverage
A
(2)
Code
Petroleum measurement
Specialty applications
Z
No specialty applications
X
ETO application
Typical model number:
3500 R 1 A 0 5 A 1 U E D B Z
(1) Requires the Model 3500 to be connected to an enhanced core processor.
(2) Not available with sensor interface code 3.
Micro Motion® Series 3000 Transmitters and Discrete Controllers
21
Ordering information — Model 3700
Model
Product description
3700
Micro Motion Coriolis multivariable transmitter and discrete controller; remote field-mount
Code
Mounting options
A
Field-mount
Code
Power supply options
1
85 to 265 VAC
2
18 to 30 VDC (recommended for 24 VDC users)
Code
Remote core processor
A
None
Sensor interface code 5
Sensor interface code 6 (remote core processor)
B
1/2″–NPT remote core processor — no gland
E
M20 remote core processor — no gland
F
Remote core processor — brass/nickel cable gland
G
Remote core processor — stainless steel cable gland
Code
Additional hardware modules
0
No additional hardware modules
1 (1)
Weights & Measures Custody Transfer (all other than OIML)
2
Weights & Measures Custody Transfer (OIML)
Code
Sensor interface
5
4-wire interface to sensors with core processors
6
4-wire remote mount transmitter with 9-wire remote core processor to sensors with junction box
Code
Conduit connections
A
M20 without glands
B
M20 with three increased safety glands
C
M20 with five increased safety glands
D
3/4-inch NPT without conduit seals
Code
Approvals
M
Micro Motion standard (no approval)
U
UL
C
CSA (Canada only)
A
CSA C-US (U.S.A. and Canada)
Z
ATEX — Zone 1 Equipment Category 2
P (2)
NEPSI — Safe area
Continued on next page
(1) Control Application code must be code D (Discrete Batch Controller).
(2) Available only with language option M (Chinese).
22
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Ordering information — Model 3700 continued
Code
Language
A
English local display
Danish quick reference guide
D
English local display
Dutch quick reference guide
English manual
E
English local display
English quick reference guide
English manual
F
French local display
French quick reference guide
French manual
G
German local display
German quick reference guide
German manual
H
English local display
Finnish quick reference guide
English manual
I
English local display
Italian quick reference guide
English manual
M
English local display
Chinese quick reference guide
English manual
N
English local display
Norwegian quick reference guide
English manual
O
English local display
Polish quick reference guide
English manual
P
English local display
Portuguese quick reference guide
English manual
S
English local display
Spanish quick reference guide
Spanish manual
W
English local display
Swedish quick reference guide
English manual
B
English local display
Hungarian CE requirements document
English manual and quick reference guide
C
English local display
Czech CE requirements document
English manual and quick reference guide
K
English local display
Slovak CE requirements document
English manual and quick reference guide
L
English local display
Latvian CE requirements document
English manual and quick reference guide
T
English local display
Estonian CE requirements document
English manual and quick reference guide
U
English local display
Greek CE requirements document
English manual and quick reference guide
V
English local display
Lithuanian CE requirements document
English manual and quick reference guide
Slovenian CE requirements document
English manual and quick reference guide
English manual
Y
English local display
Code
Control application software
Z
Process monitor/totalizer (standard)
C (1)
Process monitor/totalizer; with meter verification, structural integrity method
D
Discrete batch controller
E
(1)
Discrete batch controller; with meter verification, structural integrity method
Code
Measurement application software
Z
No measurement application software
G
Enhanced density
B
Enhanced density with predefined algorithms for food and beverage
A
(2)
Code
Petroleum measurement
Specialty applications
Z
No specialty applications
X
ETO application
Typical model number:
3700 A 1 A 0 5 A U E D B Z
(1) Requires the Model 3700 to be connected to an enhanced core processor.
(2) Not available with sensor interface option 3.
Micro Motion® Series 3000 Transmitters and Discrete Controllers
23
Ordering information — Model 3100 high energy relay
Model
Product description
3100
Micro Motion Coriolis High Energy Relay
Code
Device (order separately)
A
3 relays; 24–250 VAC; 5 A
B
3 relays; 0–70 VDC; 5 A
Code
Housing
1
No housing
2 (1)
NEMA 4X housing for relays only
Code
Future expansion
A
Reserved for future use
Code
Approvals
M
Micro Motion standard (no approval)
U
UL Class I, Div. 2, Groups A, B, C, and D
C
CSA Class I, Div. 2, Groups A, B, C, and D
B
ATEX — Equipment Category 3 (Zone 2)
Typical model number:
3100 A 2 A U
(1) Not available with approval code B.
24
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Micro Motion® Series 3000 Transmitters and Discrete Controllers
25
26
Micro Motion® Series 3000 Transmitters and Discrete Controllers
Micro Motion® Series 3000 Transmitters and Discrete Controllers
27
Micro Motion—The undisputed leader in flow and density measurement
World-leading Micro Motion measurement solutions from Emerson
Process Management deliver what you need most:
Technology leadership
Micro Motion introduced the first reliable Coriolis meter in 1977. Since
that time, our ongoing product development has enabled us to
provide the highest performing measurement devices available.
Product breadth
From compact, drainable process control to high flow rate fiscal
transfer—look no further than Micro Motion for the widest range of
measurement solutions. With the addition of Solartron® liquid and gas
density meters, Micro Motion truly is the world leader.
Unparalleled value
Benefit from expert phone, field, and application service and support
made possible by more than 500,000 meters installed worldwide and
30 years of flow and density measurement experience.
WWW.micromotion.com
© 2007 Micro Motion, Inc. All rights reserved. Micro Motion is committed to continuous product improvement. As a result, all specifications
are subject to change without notice. ELITE and ProLink are registered trademarks, and MVD and MVD Direct Connect are trademarks of
Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion
and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective owners.
Emerson Process Management
Micro Motion Americas
Worldwide Headquarters
7070 Winchester Circle
Boulder, Colorado USA 80301
T: 800 522 6277
T: +1 (303) 527 5200
F: +1 (303) 530 8459
Mexico
T: 52 55 5366 2622
Argentina
T: 54 11 4837 7000
Brazil
T: 55 15 3238 3677
Venezuela
T: 58 26 1731 3394
Emerson Process Management
Micro Motion Europe/Middle East
Central & Eastern Europe T: +41 41 7686 111
Dubai
T: 971-4 8835235
France
T: 0800 917 901
Germany
T: 0800 182 5347
Italy
T: 0800 77334
The Netherlands
T: (31) 318 495 555
U.K.
T: 0870 240 1978
Russia/CIS
T: +7 495 981 9811
Emerson Process Management
Micro Motion Asia Pacific
Australia
T: (61) 3 9721 0200
China
T: (86) 21 3895 4788
India
T: (91) 22 5662 0566
Japan
T: (81) 3 5769 6803
Korea
T: (82) 2 3438 4600
Singapore
T: (65) 6 777 8211
Download PDF

advertising