Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measurement (T&M) equipment. We stock all major equipment types such as spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz. We are focused at the professional end of the marketplace, primarily working with customers for whom high performance, quality and service are key, whilst realising the cost savings that second user equipment offers. As such, we fully test & refurbish equipment in our in-house, traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2 year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of combined experience, which enables us to deliver industry-leading service and support. We endeavour to be customer focused in every way right down to the detail, such as offering free delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan unit, if available) and supplying a free business tool with every order. As well as the headline benefit of cost saving, second user offers shorter lead times, higher reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off balance sheet accounting. Both second user and rental improve the key business measure of Return On Capital Employed. We are based near Heathrow Airport in the UK from where we supply test equipment worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house Lab. All products supplied by Test Equipment Solutions include: - No-quibble parts & labour warranty (we provide transport for UK mainland addresses). - Free loan equipment during warranty repair, if available. - Full electrical, mechanical and safety refurbishment in our in-house Lab. - Certificate of Conformance (calibration available on request). - Manuals and accessories required for normal operation. - Free insured delivery to your UK mainland address (sales). - Support from our team of seasoned Test & Measurement engineers. - ISO9001 quality assurance. Test equipment Solutions Ltd Unit 8 Elder Way Waterside Drive Langley Berkshire SL3 6EP T: +44 (0)1753 596000 F: +44 (0)1753 596001 Email: [email protected] Web: www.TestEquipmentHQ.com Agilent FieldFox Combination Analyzers 4/6.5/9/14/18/26.5 GHz Technical Overview N9913A N9914A N9915A N9916A N9917A N9918A Carry precision with you. Get Agilent-quality microwave measurements in the field Every piece of gear in your ield kit had to prove its worth. Measuring up and earning a spot is the driving idea behind Agilent’s FieldFox microwave analyzers. They’re equipped to handle routine maintenance, in-depth troubleshooting and anything in between. Better yet, FieldFox delivers Agilent-quality microwave measurements—wherever you need to go. On land, sea and air, FieldFox is ready for a wide range of applications: satellite communications, microwave backhaul, military communications, radar systems, and more. In harsh conditions and hard-toreach locations, FieldFox delivers precise results that are consistent with those you’d see on a benchtop analyzer. To get you out of the elements sooner, the taskdriven user interface will help you inish the job faster. For maximum functionality, FieldFox analyzers integrate the microwave capabilities you need in a single, compact instrument. They also give you—and your budget—more lexibility: conigure an instrument with the features you need today and add others in the future. Key Measurements Cable and antenna analyzer ● Distance-to-fault, return loss, and cable loss (1-port and 2-port) ● Integrated QuickCal – no calibration kit required ● 30 kHz to 26.5 GHz Spectrum analyzer ● Unprecedented amplitude accuracy (± 0.5 dB) with InstAlign1 – no warm up required ● Tracking generator, independent source, and preampliier covering the full frequency range ● 5 kHz to 26.5 GHz Vector network analyzer (VNA) ● All four S-parameters, magnitude and phase ● Guided Calibration Wizard, full 2-port cal, TRL, waveguide calibration ● Best trace noise and superior dynamic range for handheld VNAs ● 30 kHz to 26.5 GHz 1. With FieldFox InstAlign, internal amplitude alignments occur automatically as environmental conditions change, without any user intervention. -2- Add the world’s most precise handheld microwave analyzer to your kit Tracking generator and built-in independent signal source ● CW, CW coupled, and tracking ● Flat output power across whole frequency span, in 1 dB steps ● 30 kHz to 26.5 GHz Built-in power meter ● Easy to view analog and digital display ● ± 0.5 dB accuracy with InstAlign ● 5 kHz to 26.5 GHz Power meter using a USB power sensor ● Measure peak power and average power ● -60 to +44 dBm (sensor dependent) ● 9 kHz to 40 GHz (frequency range sensor dependent) Pulse measurements using a USB peak power sensor ● Measure peak power, average power and peak to average ratio ● Pulse proile characterization with gating ● 50 MHz to 40 GHz (frequency range sensor dependent) Vector voltmeter ● Cable trimming, phase shift and electrical length measurements ● A/B and B/A ratio measurements ● 30 kHz to 26.5 GHz -3- Designed for you and the work you do everyday Carry FieldFox wherever you need to go Field-proof usability for better answers in less time ● Kit friendly 3.0 kg or 6.6 lbs ● Large buttons are easy to operate, even when wearing gloves ● Field swappable battery lasts up to 3 1/2 hours ● Non-slip rubber grip securely its in your hands and won’t slide off the hood of your vehicle ● Vertical “portrait” orientation makes it easy to hold and operate at the same time ● Bright, low-relection display and backlit keys enable easy viewing in direct sunlight or darkness ● Intuitive user interface is designed for your worklow, enabling measurements in fewer key presses ● One-button measurements simplify complex setups and ensure quick, accurate results with conidence ● Calibration Wizard guides user to ensure simple and accurate calibrations ● 3-year warranty ensures ield conidence especially in harsh environments Large buttons make it easy to perform spectrum analysis measurements – even with gloves on -4- Transflective display makes it easy to read measurements in direct sunlight Rugged enough to meet MIL-specs ● Completely sealed instrument enclosure provides measurement stability in harsh environments ● Specially designed connector bay protects RF connectors from damage due to drops or other external impacts (designed to withstand 4’ drop on concrete surface on all 6 faces) ● Water-resistant chassis, keypad and case withstand wide temperature ranges and salty, humid environments ○ Case withstands shock and vibration ○ Wide operating temperature -10 to +55 ºC (14 to 131 ºF) ○ Wide storage temperature -51 to +71 ºC (-60 to 160 ºF) ● Meets MIL-PRF-28800F Class 2 requirements ● Type tested and meets MIL-STD-810G, Method 511.5, Procedure I requirements for operation in explosive environments ● Dust-free design with no vents or fans helps extend instrument reliability Meets IEC/EN 60529 IP53 requirements for protection from dust and water -5- Pick up FieldFox for its ergonomics Portrait design and large buttons for easy operation – even with gloves on Convenient side strap makes it easy to hold and carry Anti-glare 6.5 inch LCD display with LED backlight 11.5” (292 mm) backlit keypad Task-driven keys are grouped to easily perform field measurements Dedicated marker keys for quick marker function access 7.4” (188 mm) -6- …and depend on its durability and convenience TOP Port 1/RF output Quick connect shoulder strap clips Port 2/SA RF input Get precise location using the built-in GPS receiver Connector bay protects RF connectors External reference and external trigger input RIGHT SIDE LAN port for data transfer and SCPI porgramming Spectrum analyzer 25 MHz IF out usable for signal analysis SD flash card for data storage Keep going with field-swappable batteries that last up to 3 1/2 hours USB ports for easy data storage External reference and external trigger output Gasketed doors protect ports from moisture LEFT SIDE Built-in DC supply for powering external bias-tees, probes, and active devices Simplify interference analysis with AM/FM tune and listen -7- Cable and antenna analyzer Cable and antenna analyzer Fifty to sixty percent of microwave-link equipment issues are related to cables, antennas and connectors. Degraded feeder lines cause poor coverage, link failures, and reduced sensitivity on the receive path. To maintain the quality of a microwave link, it is critical to keep the cable and antenna systems in good working condition. Use FieldFox to make return loss, VSWR, insertion loss, 1-port cable loss, and distance-to-fault measurements. You can test antennas, cables, ilters, and ampliiers with a single instrument. The ampliiers can be biased using FieldFox’s built-in DC source. Return loss and distance-to-fault (DTF) measurements Measuring and viewing return loss and distance-to-fault simultaneously allows you to ix and tune systems much faster. Optionally, you can utilize FieldFox’s range of calibrations to ensure the instrument is always calibrated and ready to make consistent and worry-free measurements. The built-in cable editor allows you to edit existing cable types on-site, save them as new cable types with user deined names, and share the cable iles with your team. Return loss and DTF display Filter insertion loss display -8- Cable and antenna analyzer CalReady-calibrated at power on and ready to go Save time and get right to work with FieldFox’s CalReady feature. With CalReady, the analyzer is already calibrated and ready to make measurements such as S11, S22, 1-port cable loss, and DTF measurements without having to connect/ disconnect additional calibration devices. Broadband calibration FieldFox allows you to make broadband calibrations, which means the instrument is calibrated over the maximum frequency range. After a broadband calibration, you can change the frequency range or number of points without recalibrating the instrument. The calibration is interpolated, and accuracy is maintained. STEP 1 Hassle-free calibration in the field with the industry’s first and only QuickCal FieldFox is the industry’s irst and only handheld network analyzer with a built-in calibration capability that allows you to calibrate the network analyzer without carrying a calibration kit (cal kit) into the ield. With any other test instrument, when you add additional devices to the test port, such as jumper cables or adapters, you need to recalibrate using a cal kit. QuickCal eliminates the need to carry and use a cal kit, and also provides worry-free accuracy. FieldFox’s QuickCal supports measurements such as insertion loss/gain, 1-port cable loss, return loss, and DTF. User cal kit support For users who wish to use traditional mechanical calibration kits, FieldFox supports most HP/Agilent cal kits, and also allows you to deine your own custom calibration kits. Fast and accurate calibration with ECal The FieldFox calibration engine supports Agilent’s USB ECal modules. ECal support reduces calibration time and the need to make multiple connections during testing, while also providing for greater consistency between measurements. For FieldFox users, that translates into fewer human errors and increased accuracy. -9- STEP 2 STEP 3 FieldFox’s QuickCal allows you to perform calibrations without carrying a cal kit Spectrum analyzer Spectrum analyzer In microwave, radar, and satellite communications, and commercial microwave backhaul, engineers are responsible not only for hardware installation and maintenance, but also over-the-air signal quality. They need to regularly monitor for rogue signals and perform signal surveillance. FieldFox’s spectrum analyzer is optimized to excel in the dynamic spectral environment seen commonly in the ield. In the ield, users face measurement challenges such as the need to detect a low-level signal under strong signal conditions (requiring high dynamic range), or close-in small interference signals (requiring excellent phase noise). FieldFox’s superior dynamic range (TOI > +15 dBm), close in phase noise (-111 dBc/Hz at 10 kHz), and fast sweep time make these challenging tasks easier. Unprecedented amplitude accuracy without instrument warm up – InstAlign With FieldFox InstAlign, internal amplitude alignments occur automatically as the environmental conditions change, without any user intervention. This provides unprecedented amplitude accuracy up to ± 0.5 dB for spectrum analysis and power measurements. Better yet, FieldFox provides this accuracy immediately upon instrument turn on – no warm up required. Monitor the spectrum using the FieldFox analyzers Spectrum analyzer time gating FieldFox’s time gating is designed for engineers testing the pulse characteristics of their radar systems. FieldFox’s gated FFT time gating allows for signals with pulse widths as narrow as 8 µs to be measured. Triggering functions such as burst trigger and pre-trigger delay further ease pulse signal measurements. Analyze pulsed-RF signals using the spectrum analyzer time gating option FieldFox’s spectrum analyzer also provides a full power measurement suite and complete trace and state control. - 10 - Spectrum analyzer Field strength measurements Independent signal source To characterize the electric and magnetic ields, the gain and loss of the antenna and cables need to be accounted for. With FieldFox, antenna factors and cable loss data can be loaded using either the front panel or the complimentary Data Link software. FieldFox has a built-in independent signal source, with a frequency range of 30 kHz to 26.5 GHz. The signal source can be tuned to any frequency, independent of the spectrum analyzer frequency. The signal source can be used to create a test signal to measure coverage, antenna isolation, antenna direction alignment, shielding effectiveness or attenuation, transponder and frequency offset device veriication, and long cable loss measurement. Interference analyzer Interference can be internal or external, uplink or downlink, and has a direct impact on the Quality of Service of a communication network. FieldFox’s interference analyzer is designed to identify interfering signals quickly. Spectrogram and waterfall displays detect intermittent signals or monitor signals over a period of time. Signal traces can be recorded into internal memory or external lash memory devices, and the saved traces can be played back for ofline processing. It has excellent dynamic range with very fast sweep times under narrow resolution bandwidths (RBWs). Use the internal microwave signal source for transponder testing IF signal output FieldFox provides a spectrum analyzer IF output with 25 MHz bandwidth for use as a frequency down-converter, and to perform wideband signal analysis. Waterfall display makes interference hunting easier - 11 - Vector network analyzer Vector network analyzer Calibrations FieldFox’s Option 210 provides vector transmission and relection measurement (T/R), or S11 and S21, with magnitude and phase. Adding Option 211 (full 2-port S-parameters) brings new levels of accuracy and convenience for testing microwave components. FieldFox’s guided Cal Wizard takes guessing out of calibration and allows you to easily perform the following calibrations: With a full 2-port network analyzer, you can measure the forward and reverse characteristics of your component without having to disconnect, turn around, and reconnect it to the analyzer. The full 2-port calibration gives you the best measurement accuracy possible. ● Full 2-port ● OSL, response, enhanced response ● TRL, LRL, offset short Simultaneously measure and view all four S-parameters, with a single connection Port 1 Port 2: SA RF input Network analyzer receivers FieldFox’s four independent, sensitive receivers provide 94 dB of dynamic range for measurement of high rejection, narrowband devices such as cavity ilters. The receivers also enable full 2-port error correction with the unknown thru method, allowing users to measure non-insertable devices accurately and easily. FieldFox’s calibration engine is the same engine that powers the well-respected Agilent ENA and PNA network analyzers. FieldFox leverages Agilent microwave expertise to deliver consistent measurements with Agilent benchtop VNAs. A B R1 R2 Spectrum analyzer receiver SA Microwave source FieldFox microwave analyzer architecture - 12 - Vector network analyzer Network analyzer time domain Vector voltmeter With the time domain option, FieldFox computes the inverse fourier transform of the frequency-domain data to display relection or transmission coeficients versus time. Time domain gating can be used to remove unwanted responses such as connector mismatch or cable discontinuities, and the results can be displayed in either time or frequency domain. Using FieldFox’s vector voltmeter (VVM), the phase shift and electrical length of a device can be measured. You can view results on the large display as far as ten feet or three meters away. VVM also provides ratio measurements of magnitude and phase of two channels, A/B or B/A. You can use this capability to verify the magnitude and phase differences between multiple signal paths such as in an antenna or phased array. Waveguide support Waveguides are widely used to provide transmission links between microwave transmitters and antennas, as waveguides have less loss than coax. Agilent offers both high-performance and also economical waveguide calibration kits. The economical kits are ideal for ield maintenance and troubleshooting, as they provide good measurement results at lower costs. Time domain measurements provide insight into the device under test FieldFox offers all the key functionalities of the HP 8508A, in a handheld form factor, and without the need for the source/ bridge/accessories required with HP 8508A. Vector voltmeter used for cable trimming - 13 - Completing the all-in-one Built-in power meter Built-in GPS By leveraging InstAlign technology, FieldFox is able to make very accurate channel power measurements. The channel bandwidth can be set wide to simulate average power meter measurements. This measurement function provides the lexibility to make user deinable channel power measurements with accuracy up to ± 0.5 dB. A built-in GPS receiver provides geolocation tags to measurements. The geo data – time, latitude, longitude, and elevation – can be displayed and saved in data iles. In addition to location information, the GPS provides an accurate frequency reference to improve accuracy. USB power sensor support FieldFox can connect with the Agilent USB power sensors to make microwave power measurements up to 40 GHz. Using USB peak power sensors, users can measure both the average and the peak power of a modulated signal. Pulse measurements FieldFox’s pulse measurement option allows users to eficiently characterize pulsed-RF signals such as those used in radar and electronic warfare systems, leveraging the Agilent USB peak power sensors (available in 18 and 40 GHz models). Measurements include peak power, peak to average ratio, and pulse proile parameters such as rise time, fall time and pulse repetition frequency. Easily measure power levels using the built-in channel power meter Built-in variable voltage DC bias FieldFox has a built-in variable voltage DC bias source. The source provides 1 to 32 VDC with maximum current of 650 mA and 8 W maximum power. The DC bias source can provide DC power to ampliiers under test and bias tower mounted ampliiers (TMA) when engineers need to sweep through the TMA to reach the antenna (bias-tees available separately). - 14 - Use FieldFox to characterize pulses Use the built-in GPS to obtain geo-location data Remote control capability with iPad or iPhone Engineers and technicians can now remotely monitor and control their FieldFox using their iOS device such as an iPhone, iPad, or iPod Touch. FieldFox’s Remote Viewer iOS app emulates the front panel of the unit, so users can simply press any FieldFox key right from their iOS device. The app also allows users to instantly access technical documents such as data sheets. Control and view your FieldFox via your iPad FieldFox’s Data Link software makes report generation and documentation easier FieldFox’s complimentary Data Link software provides data transfer, data deinition and report generation. Markers and limit lines can be added to the traces. Cable iles and antenna factors can also be loaded using Data Link. Use the complimentary Data Link software to generate reports Remote control via LAN and FieldFox programming FieldFox analyzers are fully SCPI compliant and can be controlled over the LAN. Remotely control FieldFox using SCPI over LAN - 15 - Specifications in brief See the FieldFox Handheld Analyzer Data Sheet for a complete listing of the speciications: http://cp.literature.agilent.com/litweb/pdf/5990-9783EN.pdf Cable and antenna analyzer and vector network analyzer The performance listed in this section applies to the cable and antenna analyzer (referred to as CAT) and vector network analyzer (VNA) capabilities available in the following models (may require options – see coniguration guide): FieldFox microwave combination analyzers: N9913A, N9914A, N9915A, N9916A, N9917A, N9918A FieldFox microwave vector network analyzers: N9925A, N9926A, N9927A, N9928A Models Frequency range N9913A 30 kHz to 4 GHz N9914A 30 kHz to 6.5 GHz N9915A, N9925A 30 kHz to 9 GHz N9916A, N9926A 30 kHz to 14 GHz N9917A, N9927A 30 kHz to 18 GHz N9918A, N9928A 30 kHz to 26.5 GHz Data points or resolution 101, 201, 401, 601, 801, 1001, 1601, 4001, 10,001 Arbitrary number of points settable through SCPI IF bandwidth1 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz System impedance 50 ohm (nominal), 75 ohm with appropriate adapter and calibration kit Test port output power: Port 1 or port 2, high power, 23 ± 5 °C Frequency 30 kHz to 300 kHz Typical -11 dBm > 300 kHz to 2 MHz -3 dBm > 2 MHz to 625 MHz -2 dBm > 625 MHz to 3 GHz +1 dBm ≥ 3 to 6.5 GHz -1 dBm ≥ 6.5 to 9 GHz -2 dBm ≥ 9 to 14 GHz -4 dBm ≥ 14 to 18 GHz -6 dBm ≥ 18 to 23 GHz -10 dBm ≥ 23 to 26.5 GHz -12 dBm Power level accuracy ± 1.5 dB at -15 dBm (typical) CAT: High, low and manual. Low power is -45 dBm (nominal). Power range Power step size VNA: High, low and manual. Low power is -45 dBm (nominal). Flat power, in 1 dB steps, is available across the whole frequency span (nominal). 1. VNA mode only. Recommend using averaging in CAT mode. - 16 - System dynamic range1: Port 1 or port 2, high power, 300 Hz IF bandwidth, -10 to 55 °C Frequency Spec Typical > 300 kHz to 9 GHz2 95 dB 100 dB ≥ 9 to 14 GHz 91 dB 97 dB ≥ 14 to 18 GHz 90 dB 94 dB ≥ 18 to 20 GHz 87 dB 90 dB ≥ 20 to 25 GHz 74 dB 79 dB > 25 to 26.5 GHz 65 dB 70 dB Trace noise3: Port 1 or port 2, high power, 300 Hz IF bandwidth, spec, -10 to 55 °C Frequency Magnitude Phase > 300 kHz to 10 GHz ± 0.002 dB (rms) ± 0.014 degrees > 10 to 20 GHz ± 0.004 dB (rms) ± 0.027 degrees > 20 to 26.5 GHz ± 0.010 dB (rms) ± 0.066 degrees Measurements CAT Distance-to-fault (dB), return loss, VSWR, distance-to-fault (VSWR), cable loss (1-port), insertion loss (2-port)4, distance-to-fault (linear or Rho) VNA T/R S11, S215 VNA S-parameters S11, S21, S22, S126 Calibration types CalReady, 1-port, QuickCal, 1-port , SOL, 1-port, frequency response, enhanced response (also known as one-path, two-port), CalReady, 2-port QuickCal, 2-port SOLT or offset short, 2-port SOLT calibration, 2-port unknown thru calibration Connectors Type-N 50 ohm, Type-N 75 ohm, 7/16, TNC, 3.5 mm, 2.4 mm, waveguide bands: X-band WR-90, P-band WR-62, K-band WR-42. Custom coaxial or waveguide calibration kits can be added to any FieldFox analyzer. 1. For CAT mode “Insertion loss (2-port)”, decrease listed dynamic range speciications by 20 dB, as CAT mode IFBW is ixed at 10 kHz. Can obtain full dynamic range by using S21 measurement in VNA mode with 100 Hz IFBW. 2. < 300 kHz, 63 dB (nominal) 2 MHz to 9 MHz: 85 dB spec, 90 dB typical 3. For CAT mode, increase trace noise by a factor of 5.7, as CAT mode IFBW is ixed at 10 kHz. Can use averaging in CAT mode to reduce trace noise, or use VNA mode with 300 Hz IFBW. 4. All measurements standard are on N991xA analyzers except insertion loss (2-port). Insertion loss (2-port) requires Option 210. All measurements are available on N992xA analyzers with Option 305. 5. Standard on N992x VNAs. Option 210 required on N991xA analyzers. 6. Option 211 required to obtain all four S-parameters. - 17 - Vector voltmeter (VVM), Option 308 The performance listed in this section applies to the VVM mode capabilities available in the following models: FieldFox microwave combination analyzers: N9913A, N9914A, N9915A, N9916A, N9917A, N9918A FieldFox microwave vector network analyzers: N9925A, N9926A, N9927A, N9928A Models Frequency range N9913A 30 kHz to 4 GHz N9914A 30 kHz to 6.5 GHz N9915A, N9925A 30 kHz to 9 GHz N9916A, N9926A 30 kHz to 14 GHz N9917A, N9927A 30 kHz to 18 GHz N9918A, N9928A 30 kHz to 26.5 GHz Spectrum analyzer The speciications in this section apply to the spectrum analyzer capabilities available in the following models: FieldFox microwave combination analyzers: N9913A, N9914A, N9915A, N9916A, N9917A, N9918A FieldFox microwave spectrum analyzers: N9935A, N9936A, N9937A, N9938A Models Frequency range N9913A 100 kHz to 4 GHz Usable to 5 kHz N9914A 100 kHz to 6.5 GHz Usable to 5 kHz N9915A, N9935A 100 kHz to 9 GHz Usable to 5 kHz N9916A, N9936A 100 kHz to 14 GHz Usable to 5 kHz N9917A, N9937A 100 kHz to 18 GHz Usable to 5 kHz N9918A, N9938A 100 kHz to 26.5 GHz Usable to 5 kHz The spectrum analyzer is tunable to 0 Hz or DC. The preampliier covers the full band with nominal gain of 20 dB. Frequency reference: -10 to 55 ºC Accuracy ± 0.7 ppm (spec) + aging ± 0.4 ppm (typical) + aging Accuracy, when locked to GPS ± 0.025 ppm (spec) Aging rate ± 1 ppm/yr for 20 years (spec), will not exceed ± 3.5 ppm Frequency span Spec Resolution 1 Hz - 18 - Spec Resolution bandwidth (RBW) Range (-3 dB bandwidth) Zero span: 10 Hz to 5 MHz Non-zero span: 1 Hz to 5 MHz Video bandwidth (VBW) 1 Hz to 5 MHz Non-zero span: 1, 1.5 ,2, 3, 5, 7.5, 10 sequence Zero span: RBW/VBW ≤ 100 Phase noise: Stability, SSB phase noise at 1 GHz Offset Spec (23 ± 5 ºC) Spec (-10 to 55 ºC) Typical (23 ± 5 ºC) Typical (-10 to 55 ºC) 10 kHz -106 dBc -106 dBc -111 dBc -111 dBc 30 kHz -106 dBc -104 dBc -108 dBc -110 dBc 100 kHz -100 dBc -99 dBc -104 dBc -105 dBc 1 MHz -110 dBc -110 dBc -113 dBc -113 dBc 3 MHz -119 dBc -118 dBc -122 dBc -122 dBc 5 MHz -120 dBc -120 dBc -123 dBc -123 dBc Displayed average noise level (DANL): RMS detection, log averaging, reference level of -20 dBm, normalized to 1 Hz RBW Preamp on Spec (23 ± 5 ºC) Spec (-10 to 55 ºC) Typical (23 ± 5 ºC) Typical (-10 to 55 ºC) 2 MHz to 4.5 GHz1 -153 dBm -151 dBm -155 dBm -154 dBm > 4.5 to 7 GHz -149 dBm -147 dBm -151 dBm -150 dBm > 7 to 13 GHz -147 dBm -145 dBm -149 dBm -148 dBm > 13 to 17 GHz -143 dBm -141 dBm -145 dBm -144 dBm > 17 to 22 GHz -140 dBm -139 dBm -143 dBm -142 dBm > 22 to 25 GHz -134 dBm -132 dBm -137 dBm -134 dBm > 25 to 26.5 GHz -128 dBm -126 dBm -131 dBm -129 dBm 50 MHz absolute amplitude accuracy: 50 MHz, veriied with input level of 0 to -35 dBm, peak detector, 10 dB attenuation, preampliier off, 30 kHz RBW, all settings auto-coupled, no warm-up required, -10 to 55 ºC ± 0.3 dB (spec) ± 0.10 dB (typical) Total absolute amplitude accuracy Veriied with input level of -5 dBm. Peak detector, 10 dB attenuation, preampliier off, 30 kHz RBW, all settings auto-coupled, no warmup required. Includes frequency response uncertainties. Spec (23 ± 5 ºC) Spec (-10 to 55 ºC) Typical (23 ± 5 ºC) Typical (-10 to 55 ºC) 100 kHz to 18 GHz ± 0.8 dB ± 1.0 dB ± 0.35 dB ± 0.50 dB > 18 GHz to 26.5 GHz ± 1.0 dB ± 1.2 dB ± 0.50 dB ± 0.60 dB 1. Increase the noise loor 4 dB for frequencies between 2.1 and 2.8 GHz. - 19 - Third order intermodulation distortion (TOI) Two -20 dBm signals, 100 kHz spacing at input mixer, -10 to 55 °C Spec Typical at 2.4 GHz, +15 dBm < 1 GHz, +10 dBm 1 to 7.5 GHz, +15 dBm > 7.5 GHz, +21 dBm Tracking generator or independent source The speciications in this section apply to the tracking generator or independent source capabilities available in the following models: FieldFox microwave combination analyzers: N9913A, N9914A, N9915A, N9916A, N9917A, N9918A. FieldFox microwave spectrum analyzers: N9935A, N9936A, N9937A, N9938A. Model Tracking generator or independent source frequency range N9913A 30 kHz to 4 GHz N9914A 30 kHz to 6.5 GHz N9915A, N9935A 30 kHz to 9 GHz N9916A, N9936A 30 kHz to 14 GHz N9917A, N9937A 30 kHz to 18 GHz N9918A, N9938A 30 kHz to 26.5 GHz Dynamic range: Typical, -10 to 55 ºC Frequency Preamp off Preamp on 2 MHz to 2 GHz 97 dB 112 dB > 2 to 7 GHz 93 dB 108 dB > 7 to 11 GHz 88 dB 103 dB > 11 to 16 GHz 79 dB 94 dB > 16 to 21 GHz 71 dB 86 dB > 21 to 23 GHz 55 dB 70 dB > 23 to 25 GHz 50 dB 65 dB > 25 to 26.5 GHz 45 dB 60 dB Built-in power meter The speciications in the sections that follow apply to these FieldFox analyzers: FieldFox microwave combination analyzers: N9913A, N9914A, N9915A, N9916A, N9917A, N9918A FieldFox microwave vector network analyzers: N9925A, N9926A, N9927A, N9928A FieldFox microwave spectrum analyzers: N9935A, N9936A, N9937A, N9938A Models Frequency range N9913A 100 kHz to 4 GHz Usable to 5 kHz N9914A 100 kHz to 6.5 GHz Usable to 5 kHz N9915A, N9925A, N9935A 100 kHz to 9 GHz Usable to 5 kHz N9916A, N9926A, N9936A 100 kHz to 14 GHz Usable to 5 kHz N9917A, N9927A, N9937A 100 kHz to 18 GHz Usable to 5 kHz N9918A, N9928A, N9938A 100 kHz to 26.5 GHz Usable to 5 kHz - 20 - Amplitude accuracy Spec (23 ± 5 ºC) Typical (23 ± 5 ºC) Spec (-10 to 55 ºC) Typical (-10 to 55 ºC) 100 kHz to 18 GHz ± 0.8 dB ± 0.35 dB ± 1.0 dB ± 0.50 dB > 18 GHz to 26.5 GHz ± 1.0 dB ± 0.50 dB ± 1.2 dB ± 0.60 dB General information Calibration cycle 1 year Weight 3.0 kg or 6.6 lbs including battery Dimensions: H x W x D 292 x 188 x 72 mm 11.5” x 7.4” x 2.8” Environmental MIL-PRF-28800F Class 2 Operating temperature Storage temperature Operating humidity Random vibration Functional shock Bench drop MIL-STD-810G, Method 511.5 Type tested and meets Procedure I requirements for operation in explosive environments Altitude – operating 9144 m or 30,000 ft (using battery) Altitude – non-operating 15,240 m or 50,000 ft IEC/EN 61326–1 Complies with European EMC directive 2004/108/EC CISPR Pub 11 Group 1, class B, Group 1 limit of CISPR 11:203/EN 55011:2007 AS/NZS CISPR 11 ICES/NMB–001 Battery Lithium ion, 10.8 V, 4.6 A-h, 3.5 hours (typical) Warranty 3-year warranty standard on all FieldFox instruments - 21 - Configuration information in brief See the FieldFox Coniguration Guide for complete information on all FieldFox products and accessories. http://cp.literature.agilent.com/litweb/pdf/5990-9836EN.pdf Model Description Test port connector N9913A FieldFox RF combination analyzer, 4 GHz Type-N (f) test ports, 50 ohm N9914A FieldFox RF combination analyzer, 6.5 GHz Type-N (f) test ports, 50 ohm N9915A FieldFox microwave combination analyzer, 9 GHz Type-N (f) test ports, 50 ohm N9916A FieldFox microwave combination analyzer, 14 GHz Type-N (f) test ports, 50 ohm N9917A FieldFox microwave combination analyzer, 18 GHz Type-N (f) test ports, 50 ohm N9918A FieldFox microwave combination analyzer, 26.5 GHz 3.5 mm (m) test ports, 50 ohm Options Descriptions Measurements /functions Base unit for N9913/4/5/6/7/8A analyzers Cable and antenna analyzer Return loss, VSWR, distance-to-fault Cable loss (1-port) Insertion loss (2-port, requires Option 210) Option 210 Vector network analyzer – transmission and relection S11, S21 magnitude and phase Log and linear display, Smith chart, group delay Response cal and enhanced response cal Option 211 (requires Option 210) Vector network analyzer – full 2-port S-parameters Adds reverse S-parameters, S12 and S22, and full 2-port calibration Option 010 (requires Option 210, recommend 211) Vector network analyzer time domain Time domain and distance domain data Gating/windowing Option 112 QuickCal Calibration without using external calibration kit Option 233 Spectrum analyzer Spectrum analyzer CHP, ACPR, OBW, ield strength measurements, independent source Option 235 (requires Option 233) Preampliier 20 dB gain nominal Option 236 (requires Option 233) Interference analyzer and spectrogram Spectrogram and waterfall display Record / playback Option 238 (requires Option 233) Spectrum analyzer time gating Analyze pulsed signals Option 302 External USB power sensor support Requires Agilent U2000 series power sensor Option 307 GPS receiver (receiver built-in, external antenna required) Geo location information Lock internal reference to GPS Option 308 Vector voltmeter Cable trimming, 2-port transmission, A/B and B/A Option 309 DC bias variable-voltage source +1 to 32 VDC for external bias-tee and other devices Option 310 Built-in power meter Built-in power measurement, using the built-in receiver, without a power sensor Option 330 Pulse measurements Requires Agilent USB peak power sensor Option 030 Remote control capability Remote viewing and control using iPhone, iPad or iPod Touch (for A/B and B/A, requires Option 210 and Option 211) - 22 - Spectrum analysis Cable and antenna analysis Vector voltmeter measurements Built-in power meter Vector network analysis Interference analysis Channel power measurement Tracking generator FieldFox analyzers FieldFox Model number Maximum frequency range Cable and antenna analyzer Vector network analyzer Spectrum analyzer, Interference analyzer Tracking generator, Independent source Vector voltmeter Built-in power meter Power meter with USB sensor Pulse measurements Remote control using iOS device RF & microwave combination analyzers Microwave vector network analyzers Microwave spectrum analyzers N9913/4/5/6/7/8A N9925/6/7/8A N9935/6/7/8A 9, 14, 18, 26.5 GHz 9, 14, 18, 26.5 GHz 4, 6.5, 9, 14, 18, 26.5 GHz - 23 - VSWR and relection Accessories The accessories shown here are a subset of the available accessories. For a complete list, visit www.agilent.com/ind/n9910x N9910X-704 Phase stable cable ● Type-N(m) to TNC(f) ● 13 GHz N9910X-709 Phase stable cable ● 3.5 mm(f) to 3.5 mm(f) ● 26.5 GHz N9910X-872 External battery charger N990X-873 AC/DC adaptor N9910X-874 Bias-tee N9910X-810 Phase stable cable ● Type-N(m) to Type-N(m) ● 6 GHz N9910X-875 DC car charger and adapter N9910X-845 Adaptor kit N9910X-881 Hard transit case N9910X-860 Fixed attenuator ● 40 dB ● 100 W ● FieldFox its inside hard transit case N9910X-880 Soft transit case ● ● N9910X-870 Extra battery - 24 - Comes standard with each FieldFox Includes backpack and shoulder straps Accessories The accessories shown here are a subset of the available accessories. For a complete list, visit www.agilent.com/ind/n9910x N9910X-800 3-in-1 85520A 4-in-1 ● OSL ● ● 6 GHz ● 26.5 GHz ● Type-N(m) ● 3.5mm (m) ● 50 ohm ● 50 ohm OSLT 85515A 4-in-1 ● OSLT ● 9 GHz ● Type-N(f) ● 50 ohm 85521A 4-in-1 ● OSLT ● 26.5 GHz ● 3.5mm (f) ● 50 ohm 85518A 4-in-1 ● OSLT ● 18 GHz ● Type-N(m) ● 50 ohm 85519A 4-in-1 ● OSLT ● 18 GHz ● Type-N(f) ● 50 ohm N9910X-820 Directional antenna N9910X-821 Telescopic whip antenna - 25 - Carry precision with you. www.agilent.com www.agilent.com/find/FieldFox Every piece of gear in your ield kit had to prove its worth. Measuring up and earning a spot is the driving idea behind Agilent’s FieldFox microwave analyzers. They’re equipped to handle routine maintenance, in-depth troubleshooting and anything in between. Better yet, FieldFox delivers Agilent-quality microwave measurements - wherever you need to go. Add FieldFox to your kit and carry precision with you. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Related literature Number FieldFox Handheld Analyzers, Brochure 5990-9779EN FieldFox Spectrum Analyzers, Technical Overview 5990-9782EN FieldFox Vector Network Analyzers, Technical Overview 5990-9781EN FieldFox Handheld Analyzers, Data Sheet 5990-9783EN FieldFox Handheld Analyzer, Coniguration Guide 5990-9836EN FieldFox N9912A RF Analyzer, Technical Overview 5989-8618EN FieldFox N9912A RF Analyzer, Data Sheet N9912-90006 FieldFox N9923A RF Vector Network Analyzer, Technical Overview 5990-5087EN FieldFox N9923A RF Vector Network Analyzer, Data Sheet 5990-5363EN Download application notes, watch videos, and learn more: www.agilent.com/find/FieldFox www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East myAgilent myAgilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience. Three-Year Warranty www.agilent.com/find/ThreeYearWarranty Agilent’s combination of product reliability and three-year warranty coverage is another way we help you achieve your business goals: increased confidence in uptime, reduced cost of ownership and greater convenience. Agilent Advantage Services www.agilent.com/find/AdvantageServices Accurate measurements throughout the life of your instruments. Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom 32 (0) 2 404 93 40 45 45 80 12 15 358 (0) 10 855 2100 0825 010 700* *0.125 €/minute 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP-01-15-14) Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Sys 2013 GLOBAL HANDHELD GENERAL PURPOSE TEST EQUIPMENT NEW PRODUCT INNOVATION LEADERSHIP AWARD www.agilent.com/quality Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2014 Published in USA, February 21, 2014 5990-9780EN
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement