Electric Dryer PRODUCT MODEL NUMBERS OVERALL DIMENSIONS EED4300V EED4400V Electrical: A four-wire or three-wire, single phase, 120-volt, 60 Hz, AC-only, electrical supply is required on a separate 15 or 20 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust. A. Small Opening Side-Swing Door 22 ³⁄₄" (57.8cm) 15¹⁄₄" (38.74 cm) 43 ³⁄₈" (110cm) 43³⁄₈" (110 cm) B. Large Opening Side-Swing Door *27 ³⁄₄" (70.5cm) *26" (66 cm) C. Wide Opening Side-Swing Door 29" (73.66cm) 29" (73.66cm) A B 22³⁄₄" (57.8 cm) 43 ³⁄₈" (110cm) 43 ³⁄₈" (110cm) 13 ³⁄₄" (34.9cm) D. Wide Opening Hamper Door *27³⁄₄" (70.5 cm) *27³⁄₄" (70.5 cm) 29" (73.66cm) 29" (73.66cm) C D *Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust vent with elbow. RECESSED AREA AND CLOSET INSTALLATION For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable. 14" max. (35.6 cm) 18" (45.7 cm) 3" (7.6 cm) 48 in. 2 (310 cm2 ) 2 24 in. 2 (155 cm ) 3" (7.6 cm) 1" 29" 1" 1" 27³⁄₄" 5¹⁄₂" (2.5 cm) (73.66 cm) (2.5 cm)(2.5 cm) (70.5 cm) (14 cm) EXHAUST VENTING A B C A. Recessed area B. Side view - closet or confined area C. Closet door with vents 4" (10.2 cm) Box hood style 4" (10.2 cm) 2.5" (6.4 cm) 4" (10.2 cm) Angled style Louvered style Vent Length Chart Box or Louvered hoods Angled hoods Number of 90° turns or elbows Type of vent 0 Rigid metal Flexible metal 64 ft (20 m) 36 ft (11 m) 58 ft (17.7 m) 28 ft (8.5 m) 1 Rigid metal Flexible metal 54 ft (16.5 m) 31 ft (9.4 m) 48 ft (14.6 m) 23 ft (7 m) 2 Rigid metal Flexible metal 44 ft (13.4 m) 27 ft (8.2 m) 38 ft (11.6 m) 19 ft (5.8 m) 3 Rigid metal Flexible metal 35 ft (10.7 m) 25 ft (7.6 m) 29 ft (8.8 m) 17 ft (5.2 m) 4 Rigid metal Flexible metal 27 ft (8.2 m) 23 ft (7 m) 21 ft (6.4 m) 15 ft (4.6 m) 1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns. 2. Determine vent length. The maximum length of the exhaust system depends upon: • The type of vent (rigid metal or flexible metal). • The number of elbows used. • Type of hood. See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use. 3. Determine the number of elbows you will need. IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart. In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10150612 04-18-08
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement