Electric Dryer PRODUCT MODEL NUMBERS EED4100S EED4300S EED4400S TEDS740P OVERALL DIMENSIONS TEDS840P TEDX340R TEDX540R TEDX640P Electrical: A four-wire or three-wire, single phase, 120/240-volt, 60 Hz, AC-only, electrical supply (or 120/208-volt electrical supply, if specified on the serial/rating plate) is required on a separate 30 amp circuit, fused on both sides of the line. Use 10 gauge solid copper wire. A time-delay fuse or circuit breaker is recommended. Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust. 22¾" (57.8cm) 15¼" (38.74cm) 43³⁄₈" (110cm) 43³⁄₈" (110cm) *27¾" (70.5cm) *26" (66cm) 29" (73.66cm) 29" (73.66cm) A B 22¾" (57.8cm) 43³⁄₈" (110cm) 43³⁄₈" (110cm) 13¾" (34.9cm) *27¾" (70.5cm) *27¾" (70.5cm) 29" (73.66cm) 29" (73.66cm) C D A. Small opening side-swing door B. Large opening side-swing door C. Wide opening side-swing door D. Wide opening hamper door * Most installations require a minimum 5 ¹⁄₂" (14 cm) clearance behind the dryer for the exhaust vent with elbow. RECESSED AREA AND CLOSET INSTALLATION 14" max. (35.6cm) 18" (45.7 cm) 3" (7.6 cm) 48 in. 2 (310 cm2 ) 2 24 in. 2 (155 cm ) 0"* (0 cm) 29" (73.66 cm) 0"* (0 cm) 27¾" 5½" 0"* (0 cm) (70.5 cm) (14 cm) B A EXHAUST VENTING Type of vent C *Additional spacing recommended Recommended hood styles Number of 90° turns or elbows 3" (7.6 cm) Box or Louvered hoods B Angled hoods For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable. A. Recessed area B. Side view - closet or confined area C. Closet door with vents Angled hood style is acceptable. 4" (10.2 cm) A 0 Rigid metal Flexible metal 64 ft (20 m) 36 ft (11 m) 58 ft (17.7 m) 28 ft (8.5 m) 1 Rigid metal Flexible metal 54 ft (16.5 m) 31 ft (9.4 m) 48 ft (14.6 m) 23 ft (7 m) 2 Rigid metal Flexible metal 44 ft (13.4 m) 27 ft (8.2 m) 38 ft (11.6 m) 19 ft (5.8 m) 3 Rigid metal Flexible metal 35 ft (10.7 m) 25 ft (7.6 m) 29 ft (8.8 m) 17 ft (5.2 m) 4 Rigid metal Flexible metal 27 ft (8.2 m) 23 ft (7 m) 21 ft (6.4 m) 15 ft (4.6 m) NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. 4" (10.2 cm) 2.5" (6.4 cm) 4" (10.2 cm) A. Louvered hood style B. Box hood style Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. 8577187 08-10-06
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement