Estate EED4400S Clothes Dryer User Manual

Estate EED4400S Clothes Dryer User Manual
Electric Dryer
PRODUCT MODEL NUMBERS
EED4100S
EED4300S
EED4400S
TEDS740P
OVERALL DIMENSIONS
TEDS840P
TEDX340R
TEDX540R
TEDX640P
Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60 Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30 amp
circuit, fused on both sides of the line. Use 10
gauge solid copper wire. A time-delay fuse or circuit
breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
22¾"
(57.8cm)
15¼"
(38.74cm) 43³⁄₈"
(110cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
*26"
(66cm)
29"
(73.66cm)
29"
(73.66cm)
A
B
22¾"
(57.8cm)
43³⁄₈"
(110cm)
43³⁄₈"
(110cm)
13¾"
(34.9cm)
*27¾"
(70.5cm)
*27¾"
(70.5cm)
29"
(73.66cm)
29"
(73.66cm)
C
D
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
* Most installations require a
minimum 5 ¹⁄₂" (14 cm)
clearance behind the dryer for
the exhaust vent with elbow.
RECESSED AREA AND CLOSET INSTALLATION
14" max.
(35.6cm)
18"
(45.7 cm)
3"
(7.6 cm)
48 in. 2
(310 cm2 )
2
24 in.
2
(155 cm )
0"*
(0 cm)
29"
(73.66 cm)
0"*
(0 cm)
27¾" 5½"
0"*
(0 cm) (70.5 cm) (14 cm)
B
A
EXHAUST VENTING
Type of
vent
C
*Additional spacing recommended
Recommended hood styles
Number of
90° turns
or elbows
3"
(7.6 cm)
Box or
Louvered
hoods
B
Angled
hoods
For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air openings are acceptable.
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Angled hood style is
acceptable.
4"
(10.2 cm)
A
0
Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
4"
(10.2 cm)
2.5"
(6.4 cm)
4"
(10.2 cm)
A. Louvered hood style
B. Box hood style
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and turns.
Avoid making 90° turns.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8577187
08-10-06