SAFETY INSTRUCTIONS
CAUTION
CAUTION
The mounting location should satisfy
the following conditions:
Sparate from radio transmitter, radar,
direction finder (at least 3m).
Locate the equipment away from air
conditioner vents.
Keep the equipment out of direct
sunlight.
Vibration should be minimal.
The location should be free of water
spray.
Observe the following compass safe
distances to prevent deviation of a
magnetic compass:
Standard
compass
IF-2500
1.40 m
Steering
compass
0.95 m
Turn off the power switch at the
switchboard before beginning the
installation.
i
TABLE OF CONTENTS
Overview............................................................................................................... 1
Installation materials ........................................................................................... 1
Spare parts ........................................................................................................... 1
Cables ................................................................................................................... 2
Mounting............................................................................................................... 2
Grounding ............................................................................................................ 2
Selection of output data format.......................................................................... 2
Cable fabrication ................................................................................................. 2
Maintenance ......................................................................................................... 5
SPECIFICATIONS
PACKING LIST
OUTLINE DRAWING
INTERCONNECTION DIAGRAM
ii
Overview
The interface for the dual GPS navigator receives data from two GPS navigators and chooses
one to output in accordance with priority order. Output data is converted to NMEA current loop,
IEC 61162-1 or contact signal and output.
12-24 VDC
Outputs data in accordance
with priority order
Output 1
Input 1
(GPS navigator)
Output 2
Output 3
Output 4
Input 2
(GPS navigator)
Output 5
Output 6
Receiving Error Alarm
Cross Track Error Alarm
Arrival Alarm
1
Mounting
Selection of output data format
This unit does not have power switch. If you
do not connect the IF-2500 to power
switchboard or circuit breaker, install an
external power switch (local supply), locating
it near the IF-2500.
The output data format is selectable by
changing a jumper block; A for IEC61162-1
and B for NMEA. For example, to select
NMEA for J4, change the jumper block from A
to B on JP401 and JP402. Do the same on J5
thru J9.
Output
Jumper
J4
J5
J6
J7
J8
J9
JP401/JP402
JP501/JP502
JP601/JP602
JP701/JP702
JP801/JP802
JP901/JP902
Factory setting
Current
IEC61162-1
loop
(A)
(B)
!
!
!
!
!
!
Cable fabrication
Use the following cables (Japan Industrial
Standard cables) or the equivalents.
TTYCS-1 (Twisted pair cable)
Current loop or IEC 61162-1 signal
Armor
Sheath
Shield
• All dimensions in millimeters.
• For added support, use nuts, bolts and
washers instead of woodscrews.
• Leave sufficient space at the sides and rear
of the unit for maintenance and servicing.
φ = 10.1 mm
Conductor
S = 0.75 mm 2
φ = 1.11 mm
CO-SPEVV-SB-C 0.2x2P
Current loop or IEC 61162-1 signal
Grounding
Vinyl sheath
To prevent mutual interface, run a ground
wire between the earth terminal on the unit
and ship’s superstructure.
Armor
Sheath
φ = 10.5 mm
2
Shield
Conductor
S = 0.2 mm 2
φ = 0.6 mm
Fabrication of CO-SPEVV-SB-C 0.2X2P
75 mm
Armor
35 mm
Sheath
33 mm
Shield
28 mm
3 mm
Earth cable
Cut unused cores and solder them to shield.
3 mm
15 mm
(Supplied)
15 mm
30 mm
Heat shrink tube
Twist and solder
Heat shrink tube
How to fabricate the signal cable
3
Fix the cable with
the cable clamp
at this location.
10-35V
J1
Power
FUSE
0.5A
Alarm output 3
J12
Alarm output 2
B
A
B
A
B
A
B
A
A
B
Alarm output 1
14P0285
JP902 JP402 JP502JP602 JP702 JP802
CR2 CR3 CR4 CR6 CR7 CR8 CR9 CR10
JP401 JP901 JP501JP601 JP701 JP801
J11
B
A
J10
Output port 5
J8
B
A
Output port 4
J7
B
A
Output port 3
B
A
J6
Output port 2
B
A
J5
B
A
Output port 1
J4
A
B
Output port 6
J9
Input port 2
S1
J3
Input port 1
J2
Jumper
A: IEC61162-1
B: Current loop
Parts location
LEDs (Normal status)
Alarm output 1
Arrival Alarm
CR6
Blinks every second.
Alarm output 2
Cross Track Error Alarm
CR7
Off.
Alarm output 3
Receiving Error Alarm
CR8
Off.
CR9
Lights when Input port 1 has
priority.
CR10
Lights when Input port 2 has
priority.
Alarm output normal closed type
Normal
Relay contact is closed.
Abnormal
Relay contact is open.
Turns the power
off
Relay contact is open.
4
Maintenance
CR2
Self test 1
CR4
The unit performs an internal self-check in
the following sequence each time power is
turned on.
1. LEDs CR7 to CR10 blink twice every 2
seconds.
2. ROM and RAM are tested.
3. LED CR6 blinks every second for normal
operation. If an error is detected during
the test, the corresponding LED is turned
on.
CR6
CR7
CR8
CR9
CR10
5. Remove the connector from J4 and plug
it into J5, J6, J7 and J8 successively,
confirming that CR2 and CR9 light as
below for each port. Then, remove the
XH6P-XH4P short connector assy., plug
in the XH6P-XH5P short connector assy.
between J2 and J9, and confirm that CR2
and CR9 light as below.
CR2
Lights when receiving NMEA data
at J2.
CR9
Lights when SIO error is detected.
• When CR7 is on, ROM is defective.
• When CR8 is on, RAM is defective.
Self test 2
The test requires an external loop to check
I/O. Follow the steps below to carry out the
test.
1. Set the DIP switch #4 of S1 to the ON
position.
2. Temporarily disconnect input and output
connectors J2 and J4.
3. Construct a pair of short connector
assemblies as below.
For J4, J5, J6 ,J7 and J8
XH6P
XH4P
RS422_OUT_A
RS422_OUT_B
NC
GND
1
2
3
4
For J9
XH6P
XH5P
RS422_OUT_A
RS422_OUT_B
NC
NC
GND
1
2
3
4
5
1
2
3
4
5
6
J2
NC
NC
RD_H
RD_C
NC
GND
1
2
3
4
5
6
J2
NC
NC
RD_H
RD_C
NC
GND
Lights when receiving NMEA data
from J2.
Lights when sending NMEA data
to J4 thru J9.
Blinks every second.
Lights when ROM error is
detected.
Lights when RAM error is
detected.
Lights when SIO error is detected.
Normally off.
6. Remove the XH6P-XH5P short
connector assy. Plug in the XH6P-XH4P
short connector assy. between J3 and J4,
J5, J6, J7 and J8 successively. Confirm
that LEDs light or blink as below.
Remove the XH6P-XH4P short
connector assy., plug in the XH6P-XH5P
short connector assy. between J3 and J9
and confirm that the LEDs light or blink
as below.
CR3
Lights when receiving NMEA data
at J3.
CR4
Lights when sending NMEA data
to J4 thru J9.
CR6
Blinks every second.
CR9
Lights when SIO error is detected.
The relay contact signal output is turned on
and off alternately every second during the
test.
Short connector assy
Fuse replacement
4. Connect the XH6P-XH4P short connector
assy. between J2 and J4.
5. Confirm that each LED lights according
to equipment status as follows:
If the fuse blows, find the cause of the
problem before replacing it. Do no use a fuse
rated more than 0.5A, since it may cause
more serious damage to the equipment.
5
FURUNO
SPECIFICATIONS OF INTERFACE UNIT
IF-2500
This equipment is used for distribution of navaids data from navigation equipment. It provides
six outputs each from two independent inputs. Alarm signal is also available to distribute three
outputs from two independent inputs.
1.
Port
Input: 2 ports (IEC61162-1)
Output: 6 ports (IEC61162-1 or Current loop)
Alarm signal Output: 3 ports (Relay contact)
2.
Alarm signal
Receiving Error Alarm, Cross Track Error Alarm, Arrival Alarm
3.
Rated voltage/Current
12-24 VDC: 0.16-0.08 A
4.
Coating Color
2.5GY 5/1.5 Newtone No.5
5.
Ambient Temperature
-15 to 55℃
6.
Relative Humidity
95%RH(40℃)
7.
Water proofing
IPX0
SP-1
E4408S01C
000-000-993
000-000-992
XH4P-002
000-000-991
XH5P-002
000-802-080
XH6P-002
000-133-817
4X16 SUS304 1シュ
3
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
(*1)
5
(*1)
1
(*1)
2
4
1
CP14-06300
MJ-A6SPF0012-100
64S4071
000-114-994
(*1)
1
Q'TY
SP14-01100
FGMB 0.5A AC125V
000-000-999
IF-2500
DESCRIPTION/CODE №
IF-2500
1.(*1)印のユニット及び部品コードは架空コードに付き注文用には使用できません。
(*1)Code numbers are not allowed to order as dummy code.
XH CONNECTOR ASSY.
XHコネクタ組品
XH CONNECTOR ASSY.
XHコネクタ組品
OUTLINE
INSTALLATION MATERIALS
SPARE PARTS
UNIT
XH CONNECTOR ASSY.
XHコネクタ組品
+TAPPING SCREW
+トラスタッピンネジ
CABLE ASSY.
ケーブル組品MJ
工事材料
FUSE
ヒューズ
予備品
INTERFACE UNIT
インタ-フェイスユニット
ユニット
NAME
PACKING LIST
HEAT-SHRINK TUBE
スミチューブF
HEAT-SHRINK TUBE
スミチューブF(Z)
POWER CABLE ASSY.
電源ケーブル組品
XH CONNECTOR ASSY.
XHコネクタ組品
NAME
OUTLINE
14CL-X-9851
000-123-379
000-568-172
10X0.25 クロ*0.5M*
000-000-995
3X0.25 クロ*1.00M*
000-000-994
VCTF1.25X2C*3M*/VH2P
XH3P-002
DESCRIPTION/CODE №
14CL-X-9851-1
1/1
1
1
(*1)
1
(*1)
3
Q'TY
1
2
3
インターフェイスユニット
INTERFACE UNIT
IF-2500
12-24VDC
A
VCTF1.25x2C/VH2P,3m,φ7.4
P
P
1
2
3
4
5
6
P
1
2
3
4
5
6
CO-0.2x2P OR
TTYCS-1 *1
航法装置
NAVIGATOR
データ入力 DATA INPUT
IEC61162-1
優先順位 (Priority): J2 > J3
CO-0.2x2P OR
TTYCS-1 *1
航法装置
NAVIGATOR
B
C
D
J1(VH2P)
1 DC+
2 DC-
J4(XH4P)
TD-H/TD-B 1
*2
TD-C/TD-A 2
NC 3
GND 4
J2(XH6P)
NC
J5(XH4P)
NC
RD-H
TD-H/TD-B 1
*2
RD-C
TD-C/TD-A 2
NC 3
NC
GND 4
GND
CO-0.2x2P OR
TTYCS-1 *1
P
CO-0.2x2P OR
TTYCS-1 *1
P
J3(XH6P)
J6(XH4P)
NC
TD-H/TD-B 1
*2
NC
TD-C/TD-A 2
RD-H
NC 3
RD-C
GND 4
NC
GND
J7(XH4P)
TD-H/TD-B 1
*2
TD-C/TD-A 2
NC 3
GND 4
CO-0.2x2P OR
TTYCS-1 *1
J8(XH4P)
TD-H/TD-B 1
*2
TD-C/TD-A 2
NC 3
GND 4
CO-0.2x2P OR
TTYCS-1 *1
J9(XH5P)
TD-H/TD-B 1
*2
TD-C/TD-A 2
NC 3
NC 4
GND 5
CO-0.2x2P OR
TTYCS-1 *1
J10(XH3P)
ALARM-OUT1-H 1
ALARM-OUT1-C 2
GND 3
CO-0.2x2P OR
TTYCS-1 *1
J11(XH3P)
ALARM-OUT2-H 1
ALARM-OUT2-C 2
GND 3
CO-0.2x2P OR
TTYCS-1 *1
J12(XH3P)
ALARM-OUT3-H 1
ALARM-OUT3-C 2
GND 3
CO-0.2x2P OR
TTYCS-1 *1
注記
*1)造船所手配。
*2)内部の設定で切替え。
P
CO-0.2x2P OR
TTYCS-1 *1
P
P
P
P
P
P
出力 OUTPUT
IEC61162-1/
CURRENT LOOP
出力 OUTPUT
IEC61162-1/
CURRENT LOOP
出力 OUTPUT
IEC61162-1/
CURRENT LOOP
出力 OUTPUT
IEC61162-1/
CURRENT LOOP
出力 OUTPUT
IEC61162-1/
CURRENT LOOP
出力 OUTPUT
IEC61162-1/
CURRENT LOOP
アラーム出力(接近警報)
ALARM OUTPUT (ARRIVAL)
アラーム出力(オフトラック)
ALARM OUTPUT (OFF TRACK)
アラーム出力(受信不良)
ALARM OUTPUT (RECEIVING ERROR)
アース銅板 *1
COPPER STRAP
NOTE
*1. SHIPYARD SUPPLY.
*2. SELECT CURRENT LOOP OR IEC61162-1 BY INNER SETTING.
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
DRAWN
31 July '03
CHECKED
APPROVED
SCALE
DWG.No.
H.MAKI
Takahashi T.
TITLE
IF-2500
名称
インターフェイスユニット
Takahashi T.
MASS
kg
C4342-C02- A
相互結線図
NAME
INTERFACE UNIT
INTERCONNECTION DIAGRAM