GE EX2100 Excitation Control User’s Guide
The GE EX2100 is a versatile excitation control system designed to meet the demanding requirements of a wide range of synchronous generators. It provides precise voltage regulation, reactive power control, and protection functions to ensure stable and efficient operation of your power generation system. With its advanced features and可靠性, the EX2100 is an ideal choice for both new and retrofit applications.
PDF
Download
Document
Advertisement
Advertisement
GEH-6632 g GE Industrial Systems ™ EX2100 Excitation Control User’s Guide g GE Industrial Systems Document: Issue Date: GEH-6632 2000-09-30 EX2100™ Excitation Control User’s Guide © 2000 General Electric Company, USA. All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met during installation, operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the matter should be referred to GE Industrial Systems, Salem, Virginia, USA. This document contains proprietary information of General Electric Company, USA and is furnished to its customer solely to assist that customer in the installation, testing, operation, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Industrial Systems. Document Identification: GEH-6632 EX2100 is a trademark of General Electric Company, USA. Cimplicity® is a registered trademark of GE Fanuc Automation North America, Inc. Ethernet™ is a trademark of Xerox Corporation. Mate-N-Lok® is a registered trademark of Amp Incorporated. Windows NT® is a registered trademark of Microsoft Corporation. Safety Symbol Legend Indicates a procedure, condition, or statement that, if not strictly observed, could result in personal injury or death. Indicates a procedure, condition, or statement that, if not strictly observed, could result in damage to or destruction of equipment. Note Indicates an essential or important procedure, condition, or statement. EX2100 User's Guide GEH-6632 Safety Symbol Legend • a This equipment contains a potential hazard of electric shock or burn. Only personnel who are adequately trained and thoroughly familiar with the equipment and the instructions should install, operate, or maintain this equipment. Isolation of test equipment from the equipment under test presents potential electrical hazards. If the test equipment cannot be grounded to the equipment under test, the test equipment’s case must be shielded to prevent contact by personnel. To minimize hazard of electrical shock or burn, approved grounding practices and procedures must be strictly followed. To prevent personal injury or equipment damage caused by equipment malfunction, only adequately trained personnel should modify any programmable machine. b • Safety Symbol Legend GEH-6632 EX2100 User’s Guide To: g GE Industrial Systems Documentation Design, Rm. 291 1501 Roanoke Blvd. Salem, VA 24153-6492 USA Reader Comments Fax: 1-540-387-8651 (GE Internal DC 8-278-8651) General Electric Company We welcome comments and suggestions to make this publication more useful. Your Name Today’s Date Your Company’s Name and Address Job Site GE Requisition No. If needed, how can we contact you? Fax No. Phone No. E-mail Your Job Function / How You Use This Publication Publication No. Address Publication Issue/Revision Date General Rating Contents Organization Technical Accuracy Clarity Completeness Drawings / Figures Tables Referencing Readability Excellent ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ Good ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ Fair ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ Poor ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ Additional Comments _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ Specific Suggestions (Corrections, information that could be expanded on, and such.) Page No. Comments ______ __________________________________________________________________________________ ______ __________________________________________________________________________________ ______ __________________________________________________________________________________ ______ __________________________________________________________________________________ ______ __________________________________________________________________________________ ______ __________________________________________________________________________________ Other Comments (What you like, what could be added, how to improve, and such.) ________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Overall grade (Compared to publications from other manufacturers of similar products, how do you rate this publication?) ¡ Superior ¡ Comparable ¡ Inferior Detach and fax or mail to the address noted above. ¡ Do not know Comment ____________________________________________ ......................................................................... Fold here and close with staple or tape .......................................................................................... ____________________________ Place stamp here. ____________________________ ____________________________ GE Industrial Systems Documentation Design, Rm. 291 1501 Roanoke Blvd. Salem, VA 24153-6492 USA ...........................................................................................Fold here first ......................................................................................................... Contents Chapter 1 Equipment Overview 1-1 Introduction............................................................................................................................ 1-1 System Overview ................................................................................................................... 1-2 Hardware Overview ............................................................................................................... 1-5 Software Overview................................................................................................................. 1-6 Technical Characteristics ....................................................................................................... 1-6 How to Get Help .................................................................................................................... 1-8 Related Documents ................................................................................................................ 1-8 Document Distribution............................................................................................. 1-8 Chapter 2 Functional Description 2-1 Introduction............................................................................................................................ 2-1 Exciter Hardware ................................................................................................................... 2-2 Exciter Configurations ........................................................................................................... 2-3 Power Conversion Cabinet..................................................................................................... 2-5 Manual Ac Disconnect (Optional) ........................................................................... 2-5 Power Conversion Module (PCM)............................................................................. 2-5 Gate Pulse Amplifiers (EGPA Board) ..................................................................... 2-6 Main Dc Contactors. 41A or 41A/41B (Optional)................................................... 2-7 Free Wheeling Diode De-excitation ........................................................................ 2-7 Auxiliary Cabinet ................................................................................................................... 2-8 Ac Line-to-Line Filters ............................................................................................ 2-8 De-excitation Module (EDEX) ................................................................................ 2-8 Shaft Voltage Suppressor......................................................................................... 2-9 Field Flashing Module ............................................................................................. 2-9 Field Ground Detector (EXAM and EGDM)........................................................... 2-9 High Voltage Interface – HVI.................................................................................. 2-9 Control Cabinet .................................................................................................................... 2-10 Diagnostic Interface (Keypad) ............................................................................... 2-10 Control Module...................................................................................................... 2-11 Simplex Control System ........................................................................................ 2-12 Redundant Control System .................................................................................... 2-13 Control Power Supplies ......................................................................................... 2-14 Exciter Software................................................................................................................... 2-17 Auto Reference – AUTO REF ............................................................................... 2-20 AVR Setpoint – EXASP ........................................................................................ 2-20 Automatic Voltage Regulator – AVR .................................................................... 2-20 Manual Reference – MANUAL REF .................................................................... 2-21 Field Voltage and Current Regulators - FVR & FCR............................................ 2-21 Under Excitation Limiter – UEL ........................................................................... 2-22 Power System Stabilizer – PSS.............................................................................. 2-22 Operator Interface ................................................................................................................ 2-23 Turbine Control HMI............................................................................................. 2-23 Control System Toolbox (toolbox)........................................................................ 2-23 EX2100 User’s Guide GEH-6632 Contents • i Chapter 3 Printed Wiring Boards Overview 3-1 Introduction............................................................................................................................ 3-1 Control Boards ....................................................................................................................... 3-2 Exciter Backplane (EBKP) ...................................................................................... 3-2 Digital Signal Processor Board (DSPX) .................................................................. 3-2 ACLA Board............................................................................................................ 3-4 EISB Board.............................................................................................................. 3-4 EMIO Board ............................................................................................................ 3-4 ESEL Board ............................................................................................................. 3-5 I/O Terminal Boards .............................................................................................................. 3-5 EPCT Board............................................................................................................. 3-5 ECTB Board ............................................................................................................ 3-6 EXTB Board ............................................................................................................ 3-6 EDCF Board ............................................................................................................ 3-6 EACF Board ............................................................................................................ 3-7 Bridge and Protection Boards and Modules........................................................................... 3-7 EGPA Board ............................................................................................................ 3-7 EXCS Board ............................................................................................................ 3-7 EDEX Board............................................................................................................ 3-8 EGDM Module ........................................................................................................ 3-8 EXAM Module ........................................................................................................ 3-9 Power Supply Boards............................................................................................................. 3-9 EPDM Module......................................................................................................... 3-9 EPBP Backplane ...................................................................................................... 3-9 EPSM Module ....................................................................................................... 3-11 DACA – Ac to Dc Converter................................................................................. 3-11 Related Board Publications .................................................................................................. 3-11 Chapter 4 Terminal Board I/O and Equipment Connections 4-1 Introduction............................................................................................................................ 4-1 Power Connections and Analog I/O....................................................................................... 4-2 Power Potential Transformer Inputs ........................................................................ 4-3 Potential and Current Transformer Inputs................................................................ 4-3 Analog Input ............................................................................................................ 4-3 Customer Contact I/O ............................................................................................................ 4-4 Power Supply Inputs .............................................................................................................. 4-6 Line Filter Connections.......................................................................................................... 4-7 Exciter Internal I/O ................................................................................................................ 4-8 Exciter AC Feedback ............................................................................................... 4-8 Exciter DC Feedback ............................................................................................... 4-8 De-Excitation ....................................................................................................................... 4-11 Crowbar................................................................................................................................ 4-14 Field Ground Detector.......................................................................................................... 4-14 Field Flashing....................................................................................................................... 4-16 Dc Field Flashing Settings ..................................................................................... 4-16 Flashing Control Sequence .................................................................................... 4-16 Shaft Voltage Suppressor ..................................................................................................... 4-18 Data Highway Connections.................................................................................................. 4-19 Control System Toolbox Connection ................................................................................... 4-20 Chapter 5 Diagnostic Interface-Keypad 5-1 Introduction............................................................................................................................ 5-1 Using the Pushbuttons............................................................................................................ 5-2 Reading the Display ............................................................................................................... 5-5 ii • Contents GEH-6632 EX2100 User’s Guide Changing Display Units........................................................................................... 5-7 Adjusting Display Contrast...................................................................................... 5-7 Status Screen .......................................................................................................................... 5-8 Reading the Meters .................................................................................................. 5-8 Alternate Status Screen (Display I/O) .................................................................................... 5-8 Using the Menus .................................................................................................................... 5-9 Viewing and Resetting Faults ................................................................................................ 5-9 Editing Parameters ............................................................................................................... 5-10 Parameter Backup .................................................................................................. 5-11 Firmware and Hardware Information................................................................................... 5-13 Protecting the Keypad .......................................................................................................... 5-14 Modifying the Protections...................................................................................... 5-14 Appendix A Warranty and Renewal Parts A-1 Introduction........................................................................................................................... A-1 Identifying the Part................................................................................................................ A-2 Renewal Parts List .................................................................................................. A-2 Part Number Structure ............................................................................................ A-2 Warranty Terms .................................................................................................................... A-4 How to Order Parts ............................................................................................................... A-5 Data Nameplate....................................................................................................... A-5 ML Number ............................................................................................................ A-5 Appendix B Ratings and Specifications B-1 Glossary of Terms Index EX2100 User’s Guide GEH-6632 Contents • iii Notes iv • Contents GEH-6632 EX2100 User’s Guide Chapter 1 Equipment Overview Introduction The EX2100ä Excitation Control (EX2100 or exciter) produces the field excitation current to control generator ac terminal voltage and/or the reactive volt-amperes. It is a full static excitation system designed for generators on both new and retrofit steam, gas, and hydro turbines. This chapter introduces the exciter and defines the document contents. Its purpose is to present a general product overview as follows: Section/Topic Page System Overview..................................................................................................... 1-2 Hardware Overview................................................................................................. 1-5 Software Overview .................................................................................................. 1-6 Technical Characteristics ......................................................................................... 1-6 How to Get Help ...................................................................................................... 1-8 Related Documents .................................................................................................. 1-8 Document Distribution ..................................................................................... 1-8 Chapter 2 Functional Description Chapter 3 Printed Wiring Boards Overview Chapter 4 Terminal Boards I/O and Equipment Connections Chapter 5 Diagnostic Interface (Keypad) Appendix A Warranty and Renewal Parts Appendix B Ratings and Specifications Glossary EX2100 User’s Guide GEH-6632 Chapter 1 Equipment Overview • 1-1 System Overview The exciter is a flexible modular system that can be assembled to provide a range of available output currents and several levels of system redundancy. These options include power from a potential, compound, or auxiliary source. Single or multiple bridges, warm backup bridges, and simplex or redundant controls are available. An overview of the turbine generator excitation system is shown in Figure 1-1. Power for the exciter is drawn from a power potential transformer connected to the generator terminals, or from an excitation transformer connected to an auxiliary bus. Generator line current and stator output voltage are the primary feedbacks to the exciter, and dc voltage and current is the controlled output to the exciter field. The architecture supports Ethernet LAN (Unit Data Highway) communication with other GE equipment including the GE Control System Toolbox (toolbox) for configuration, the turbine control, the LCI Static Starter, and the HMI (operator interface). Figure 1-2 is a simplified one line diagram of the exciter showing the power source, generator current and voltage measurements, control module, power conversion module (PCM), and protection circuits. In the potential source system, the secondary of the PPT is connected to the input of a 3-phase full-wave inverting thyristor bridge. The inverting bridge provides both positive and negative forcing voltage for optimum performance. Negative forcing provides fast response for load rejection and de-excitation. Either simplex or redundant control is available. Excitation control results from phase controlling the output of the SCR bridge circuit. The SCR firing signals are generated by digital regulators in the controller. In the redundant control option (Figure 1-2), either M1 or M2 can be the active master control, while C monitors both to determine which should be the active and which the standby controller. Dual independent firing circuits and automatic tracking is used to ensure a smooth transfer to the standby controller. 1-2 • Chapter 1 Equipment Overview GEH-6632 EX2100 User’s Guide Transmission Line Step-up Transformer Air Circuit Breaker (52G) Current Transformers (CTs) Potential Transformers (PTs) Turbine Exciter Power Potential Transformer (PPT) Generator Controlled dc to Field EX2100 Exciter Data Highway to Turbine Control, HMI, & DCS Power Conversion Module (Bridge) Control, Sequencing, Protection Ac Source Instrumentation Figure 1-1 Overview of Generator and Exciter System EX2100 User’s Guide GEH-6632 Chapter 1 Equipment Overview • 1-3 AC AC Load Diagnostic Interface (Keypad) Unit Data Highway DC Control Power Supplies Customer I/O Current CT PT I/O Voltage Bridge I/O Aux Source Generator AC AC CB Control M1 Control M2 Control C PPT PCT (3) Compound Source only Linear Reactors (3) Line Filter Gating Selector AC CB or Disconnect Power Conversion Modules (Bridge) AC DC Flashing Control DC CB or Contactor Active Field Ground Detector Shunt Deexcitation Crowbar PT: Potential Transformer CT: Current Transformer CB: Circuit Breaker I/O: Input/Output PCT: Power Current Transformer PPT: Power Potential Transformer Shaft Voltage Suppression Figure 1-2. Exciter One Line Diagram 1-4 • Chapter 1 Equipment Overview GEH-6632 EX2100 User’s Guide Hardware Overview The EX2100 hardware is contained in three cabinets as follows: • control cabinet for the control, communication, and I/O boards • auxiliary cabinet for field flashing and protection circuits such as de-excitation and shaft voltage suppression • power conversion cabinet for the power SCR cells, cooling fans, dc contactors, and ac disconnect The exciter's power converter consists of bridge rectifiers, resistor/capacitor filter configurations, and control circuitry. An outside view of the cabinets is shown in Figure 1-3. The components and bridge size vary for different excitation systems and for the power output required. Control Cabinet Auxiliary Cabinet Contactors & Disconnects Fan Drawers Power Conversion Cabinet Keypads Figure 1-3. Exciter Cabinets EX2100 User’s Guide GEH-6632 Chapter 1 Equipment Overview • 1-5 Software Overview Microprocessor-based controllers (ACLA and DSPX) execute the exciter control code. The software consists of modules (blocks) combined to create the required system functionality. Block definitions and configuration parameters are stored in flash memory, while variables are stored in random-access memory (RAM). The exciter application software emulates traditional analog controls. It uses an open architecture system, with a library of existing software blocks configured from the toolbox. The blocks individually perform specific functions, such as logic gates, proportional integral (P.I.) regulators, function generators, and signal level detectors. The control selects one of two modes, either generator voltage regulation (Auto Regulation), or direct control (voltage or current, depending upon the application). Generator protection functions are integrated into the control, including over and under-excitation limiting, power system stabilization, and V/Hz limiting. The blocks can be interrogated while the exciter is running by using the toolbox. The dynamically changing I/O values of each block can be observed in operation, which is valuable during startup or troubleshooting. Technical Characteristics Summary characteristics for the EX2100 are as follows; for further details refer to Appendix B. Unit Specific ratings are provided on equipment nameplate and supercede all information herein. EX2100 Characteristics Description Power Converter Module (PCM) Single bridge rating 1,000 and 2,000 A dc at up to 1,000 V ac Parallel bridge rating 8,000 A dc at up to 1,500 V ac; with up to 6 bridges Forcing requirements 150% of design Amperes (EDA) for 30 s at 40 ºC Power Sources Power for the PCM – Voltage source Auxiliary bus Generator terminals Compound source 600 or 1,000 V ac versions Power Input for the PCM - VA 3251 kVA (1,000 V version) Power for the PCM - Frequency 3-phase 50/60 Hz Flashing power Battery source 125 V dc or 250 V dc, with up to 200 A for at least 10 s 240 or 480 V ac, 50/60 Hz single-phase auxiliary source Control power 1-6 • Chapter 1 Equipment Overview For two ac sources, or one ac and one dc source: Nominal 120 V ac ±15%, with 1 DACA, 10 A rms max. Battery source, 125 V dc, range 80 – 140 V dc, 10.6 A dc max. GEH-6632 EX2100 User’s Guide Input/Output QTY Potential transformers (PTs) 2 3-phase standard, single phase available 120 V ac nominal 1 VA nominal burden Current transformers (CTs, 1 or 5 A) 2 Any two phases, single phase available 1 VA nominal burden 86G dedicated contact input 1 open for trip 52G dedicated contact input 1 closed for online Trip rated contact outputs 2 At 125 V dc with relay break characteristics: Resistive load 0.5 A Inductive load 0.2 A General Purpose contact inputs 6 Customer contacts, 70 V dc supplied by ECTB General Purpose Form C contact outputs 4 At 125 V dc with relay break characteristics: Resistive load 0.5 A Inductive load 0.1 A ± 10 V differential amplifier input 1 Thermal Base controls cabinet Continuous operation in a 0 to 40 ºC ambient environment, with 5 to 95% humidity, non-condensing Base power conversion and auxiliary cabinet Continuous operation in a 0 to 40 ºC ambient environment, with 5 to 95% humidity, non-condensing Cabinet Dimensions & Weight Redundant control with dual PCM redundant converter in a three-cabinet lineup Width 141.74 in (3600 mm) Height 104.32 in (2650 mm) Depth 31.5 in (800 mm) Weight of Converter cabinet 3,600 lbs Weight of Total Lineup (Converter, Control, and Auxiliary cabinets) 5,600 lbs Cabinet type, control & auxiliary enclosures NEMA 1 (IEC IP 20), convection cooled Cabinet type, power conversion NEMA 1 (IEC IP 20), forced air cooled Power and Control Cable Access Entrances from the top and/or bottom EX2100 User’s Guide GEH-6632 Chapter 1 Equipment Overview • 1-7 How to Get Help “+” indicates the international access code required when calling from outside of the USA. If help is needed beyond the instructions provided in the drive system documentation, contact GE as follows: GE Industrial Systems Product Service Engineering 1501 Roanoke Blvd. Salem, VA 24153-6492 USA Phone: + 1 888 GE4 SERV (888 434 7378, United States) + 1 540 378 3280 (International) Fax: + 1 540 387 8606 (All) Related Documents The following documents also apply to the exciter and may assist in understanding the system. GEI-100256C EX2100 Receiving, Storage, & Handling GEH-6631 EX2100 Installation and Startup Guide GEH-6633 EX2100 Troubleshooting, Preventive and Online Maintenance GEH-6403 Control System Toolbox for Mark VI Turbine Controller Printed Wiring Board (GEI) publications, refer to Chapter 3. Document Distribution GE Industrial Systems supplies product documents to its customers to support the equipment provided for each requisition. The contract documents define the terms of the document distribution. If provided (per contract) the following documents contain requisition information about the drive system. • Requisition drawings, including outlines, layouts, and elementary diagrams • Renewal parts listing Note If differences exist between the general product documentation and the requisition documentation, the requisition documentation should be considered the more exact representation of your equipment or system configuration. 1-8 • Chapter 1 Equipment Overview GEH-6632 EX2100 User’s Guide Chapter 2 Functional Description Introduction This chapter describes the function of the EX2100 static exciter and the individual control and protection circuits. Power supplies and the distribution of power is also covered. The functional description information is organized as follows: Section Page Exciter Hardware ..................................................................................................... 2-2 Exciter Configurations ............................................................................................. 2-3 Power Conversion Cabinet ...................................................................................... 2-5 Manual Ac Disconnect (Optional) .................................................................... 2-5 Power Converter Module (PCM)...................................................................... 2-5 Gate Pulse Amplifiers (EGPA Board) .............................................................. 2-6 Main Dc Contactors. 41A or 41A/41B (Optional)............................................ 2-7 Free Wheeling Diode De-excitation ................................................................. 2-7 Auxiliary Cabinet..................................................................................................... 2-8 Ac Line-to-Line Filters ..................................................................................... 2-8 De-excitation Module (EDEX) ......................................................................... 2-8 Shaft Voltage Suppressor.................................................................................. 2-9 Field Flashing Module ...................................................................................... 2-9 Field Ground Detector (EXAM and EGDM) ................................................... 2-9 High Voltage Interface – HVI .......................................................................... 2-9 Control Cabinet...................................................................................................... 2-10 Diagnostic Interface (Keyad).......................................................................... 2-10 Control Module............................................................................................... 2-11 Simplex Control System ................................................................................. 2-12 Redundant Control System ............................................................................. 2-13 Control Power Supplies .................................................................................. 2-14 Exciter Software .................................................................................................... 2-17 Auto Reference – AUTO REF........................................................................ 2-20 AVR Setpoint – EXASP ................................................................................. 2-20 Automatic Voltage Regulator – AVR............................................................. 2-20 Manual Reference – MANUAL REF ............................................................. 2-21 Field Voltage and Current Regulators - FVR & FCR..................................... 2-21 Under Excitation Limiter – UEL .................................................................... 2-22 Power System Stabilizer – PSS ...................................................................... 2-22 Human Machine Interface (HMI) .......................................................................... 2-23 Mark VI HMI.................................................................................................. 2-23 Toolbox........................................................................................................... 2-23 EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-1 Exciter Hardware The EX2100 exciter consists of the following basic components. • Power Conversion Module (PCM) and cooling fans • Power potential transformer (PPT) (mounted separate from exciter) • Line-to-line filters • Shaft voltage suppressor • De-excitation module • Diagnostic Interface (keypad) • Controllers and I/O boards • Control power supplies Optional components that can be added to the exciter are: • Warm backup bridge configuration • Multibridge configuration for high current requirements • Compound power source (separate from exciter) • Auxiliary power source (bus-fed) • Crowbar module (for hydro and other special applications) • Dc Disconnect • Field ground detector • Redundant ac source for power supply • Ac disconnect • Field flashing module • Redundant controllers providing a Triple Modular Redundant (TMR) system • GE Control System Toolbox (toolbox) for configuration The control hardware is basically the same for the different types of excitation. The power conversion hardware is defined by application requirements, which therefore determines the exciter bridge size. 2-2 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Exciter Configurations EX2100 Exciters can be supplied with single or redundant control, and with single or redundant bridges. Variations of the single control type are shown in Figure 2-1. Simplex Control with Single PCM Control with I/O and Operator Keypad PCM Simplex Control with Parallel PCMs Control with I/O and Operator Keypad PCM 1 PCM 2 PCM 3 PCM 4 PCM 5 PCM 6 Figure 2-1. Simplex Control Configurations EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-3 Exciters with dual (redundant) control are shown in Figure 2-2. Multiple PCMs can be supplied in simplex, warm backup, or redundant n+1 or n+2 modes (with n+1 or n+2 equal to 6). Dual Control with Single PCM M1 Control, I/O and Operator Keypad Dual Control with Warm Backup PCMs M1 Control, I/O and Operator Keypad PCM M2 Control, I/O and Operator Keypad M2 Control, I/O and Operator Keypad C Control Selection Logic & Protection C Control Selection Logic & Protection PCM PCM Dual Control with Parallel PCMs M1 Control, I/O and Operator Keypad PCM 1 PCM 2 PCM 3 PCM 4 PCM 5 PCM 6 M2 Control, I/O and Operator Keypad C Control Selection Logic & Protection Figure 2-2. Dual Control System Configurations 2-4 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Power Conversion Cabinet The Power Conversion cabinet contains the Power Conversion Module (PCM), the Exciter Gate Pulse Amplifier (EGPA) board, ac circuit breaker, and the dc circuit contactor. Three-phase power for the PCM comes from a PPT external to the exciter. The ac supply comes into the cabinet through the ac circuit breaker (if supplied), and is filtered by 3-phase line filters in the auxiliary cabinet. Manual Ac Disconnect (Optional) The manual ac disconnect switch serves as a disconnect device between the secondary of the power potential transformer and the static exciter. It is a molded case, 3-phase, non-automatic, panel-mounted switch, which is manually operated for isolating the ac input supply. It is a no-load disconnect device. Power Conversion Module (PCM) The exciter PCM includes the bridge rectifiers, dc leg fuses, thyristor protection circuitry (for example, snubbers, filters, and fuses) and leg reactor assemblies. The components vary for different bridge ratings based on the power output required. Bridge Rectifier Each bridge rectifier is a 3-phase full-wave thyristor bridge The bridge has six SCRs (thyristors) controlled by the Exciter Gate Pulse Amplifier board (EGPA) as shown in Figure 2-3. Heat is dissipated through large aluminum cooling fins and forced air flow from overhead fans. Leg Reactors and Cell Snubbers The commutating reactors are located in the ac legs feeding the SCRs, and the snubbers are an RC circuit from the anode to the cathode of each SCR. The cell snubbers, line-to-line snubbers and line reactors together perform the following functions to prevent misoperation of the SCRs. • Limit the rate of change of current through the SCRs and provide a current dump to aid in starting conduction. • Limit the rate of change in voltage across the cell and, during cell commutation, limit the reverse voltage that occurs across the cell. The SCR snubbers include PRV resistors to limit the peak reverse voltage. These resistors can be removed if required. Three-phase input power is fed to the bridge from the secondary of the PPT, either directly or through an ac breaker or disconnect, and a line-to-line filter. With inverting bridge designs, the bridge is capable of negative forcing voltage, which provides fast response for load rejection and de-excitation. The dc current output of the bridge is fed through a shunt, and on some designs a contactor (41A or both 41A and 41B) to the generator field. The bridge design utilizes dc leg fuses to protect the SCRs from overcurrrent. EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-5 Current Shunt A dc shunt provides the bridge output current feedback signal. The mV output signal is input to a differential amplifier on the EDCF board. The amplifier output voltage controls the frequency of an oscillator, which generates a fiber-optic signal sent to the control module. The bridge output voltage feedback signal is generated in a similar way. EDCF provides dc current and voltage feedback To dc Breaker, Shunt, and Generator Field + FU1B FU1A SCR1 Ac power Input FU2B SCR2 FU3A FU3B SCR3 Snubber 1 Snubber 2 Snubber 3 Snubber 4 Snubber 5 Snubber 6 SCR4 SCR5 FU4A J1 FU2A FU4B J4 Gen. Field - J2 FU5A SCR6 FU5B J5 J3 FU6A FU6B J6 Gate Driver Inputs from EGPA Board Figure 2-3. Power Bridge Gate Pulse Amplifiers (EGPA Board) The gate pulse amplifiers directly control the SCRs. The EGPA board interfaces the control to the Power Bridge. EGPA takes the gate commands from the ESEL board in the controller, and generates the gate firing pulses for six SCRs (Silicon Controlled Rectifiers). It is also the interface for current conduction feedback, and bridge airflow and temperature monitoring. On a new exciter, an RTD is used to monitor the temperature and generate alarms instead of the Klixon switches. Additional switches actuated by fan rotation monitor cooling air flow across the bridge. On an exciter controls only retrofit, the exciter may have provisions for accepting feedback from two thermal switches mounted on the SCR heatsink assemblies. One thermal switch opens at the alarm level (170 °F (76 °C)) and the other at the trip level (190 °F (87 °C)). These switches are wired to the EGPA board and may require retrofitting into the existing bridge. If either switch opens, a bridge overtemperature alarm is generated. If both switches open, a fault and a trip are generated. 2-6 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Cooling Fan Assembly The SCR bridge assembly is cooled with forced air. From two to six overhead fans are used, depending on the bridge rating and redundancy requirements. The fans are powered by single-phase 115 V ac supplied by the customer. In redundant applications, a fan may be replaced while the exciter is running. Main Dc Contactors. 41A or 41A/41B (Optional) The main dc contactor (at the output of the power conversion module) provides a disconnect between the power conversion module and the generator field. The contactor picks up when the running mode is selected and no fault exists in the excitation. The contactors are normally actuated using pilot relays on the EXTB board driven by the controller. The auxiliary contacts from the contactor are routed back through the EXTB board as feedback signals. Free Wheeling Diode De-excitation De-excitation, the dissipation of the field current after the dc contactor opens, can be done with a free wheeling diode. This diode is connected from the generator field negative lead (anode) to the positive lead (cathode). The reverse voltage causes current to flow through the diode, and the field resistance causes the current decay. EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-7 Auxiliary Cabinet The auxiliary cabinet is located next to the power conversion cabinet and contains modules to protect the generator and provide startup dc power. Modules for filtering the incoming ac power, for de-excitation, shaft voltage suppression, and field flashing are mounted in this cabinet. Ac Line-to-Line Filters Fuse protected line-to-line series RC filter circuits (snubbers) are provided to damp the ac system to prevent voltage spikes at the completion of SCR commutation. There are two styles of filters employed depending on the voltage. The 600 V filter uses RC circuits and MOVs. The 1000 V filter uses the 600 V version with additional RC circuits. Refer to Chapter 4 for details and connections. De-excitation Module (EDEX) During any shutdown, the energy stored in the generator field must be dissipated. In a normal shutdown, a stop is initiated by an operator. The bridge is fired at retard limit and sufficient time is allowed for the field to decay before the field contactors are opened. During an abort stop (trip), the field contactors are opened immediately. The stored field energy must be dissipated through some other means. SCR De-excitation Module (EDEX) For customers requiring a rapid de-excitation, an SCR de-excitation module is provided. In the EDEX module, an SCR is fired to provide a conduction path through the field discharge resistor (or inductor) for the field current to flow and dissipate the field energy. The de-excitation module has dual independent firing control circuits. Each is activated by a parallel combination of auxiliary contacts representing the status of the field contactor(s), bridge ac supply breaker, and exciter bridge operating state. Any one of these paths can gate the de-excitation SCR which does not conduct unless the field voltage is inverted. If neither firing control circuit can fire the SCR, it is fired on overvoltage when the anode to gate voltage on the SCR exceeds the break over voltage of the breakover diode string connected between the anode and gate. De-excitation modules can be paralleled for larger excitation systems. Thyrite In systems that do not use the standard de-excitation module, a thyrite is connected across the dc output buses of the thyristor bridge. This protects the thyristors from high peak inverse voltages, which may occur as a result of abnormal generator operation. These are typically only supplied on salient pole generators. 2-8 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Shaft Voltage Suppressor The Shaft Voltage Suppressor protects the shaft bearings. Excitation systems, which produce a dc voltage from ac through a solid state rectification process, produce ripple and spike voltages at the exciter output. Due to their rapid rise and decay times, these voltages are capacitively coupled from the field winding to the rotor body. This creates a voltage on the shaft relative to ground. Shaft voltage, if not effectively controlled, can be damaging to both journals and bearings. The shaft voltage suppressor is a filter that conducts the high frequency components of the induced voltages to ground. (This filter is shipped loose in some cases, otherwise it is part of the lineup). Field Flashing Module The field flashing module is provided on generator terminal fed excitation systems. It supplies initial exciter current and builds generator voltage, supplying approximately 10% - 15% of no-load field current from the station batteries during the startup sequence. If large machines require ac field flashing, the ac power is supplied through an isolation transformer. Both designs require customer supplied power. Field Ground Detector (EXAM and EGDM) The field ground detector protects the generator shaft. The generator field winding is electrically isolated from ground. The existence of one ground usually does not damage the rotor. However, the presence of two or more grounds in the field winding path causes magnetic and thermal imbalances and localized heating, which may damage the rotor forging or other metallic parts. The function of the field ground detector is to detect a ground path from any exciter component connected to and including the main field windings. The Exciter Attenuator Module (EXAM) drives the electrical center of the field winding with a low frequency ac voltage relative to ground. To detect the current flow, the voltage across a sensing resistor is picked up by EXAM and measured by the EGDM module. This signal is sent over a fiber-optic link to the controller where it is monitored and alarmed. The EGDM boards (1 for simplex and 3 for redundant) are mounted in the control power supply module located in the control cabinet. High Voltage Interface – HVI The HVI contains the ac and dc bus, plus the line filter fuses. It also contains two terminal boards providing bridge feedback to the control and the EXAM board. The EACF board accepts incoming PPT ac voltage and air core CT current signals. It has transformers to isolate the voltages and produce low level signals. The EDCF board measures the bridge dc current and voltage, and sends it over fiber-optics to the control. EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-9 Control Cabinet The control cabinet contains the keypad control rack, control power distribution module and supplies, and I/O terminal boards. Diagnostic Interface (Keypad) The keypad is a local operator interface that is mounted on the control cabinet door. Refer to Figure 2-4 for a view of the keypad and a summary of the operator and maintenance functions available. Chapter 5 describes the keypad in detail. A second keypad is provided for redundant controls. g EX2100 Excitation Control FVR Feedback 0.0 Volts FldCurrAmps 0.00 Amps Vmag Exciter Health & State Icons -30% 0% -30% 0% 100% 150% 100% 150% Imag 0.00 Watts 0.00 Freq_Hz 0.00 Balance Meter 60.00 Vars 0.00 0.00 Exciter Control Navigation Run (Green) Status Reset Faults Auto Menu Command Man Menu Voltage Level Escape On Enter Stop (Red) Off Display: Pushbuttons: Status screens provide analog and digital representation of exciter functions and values. Organized into functional groups: Menu screens provide text-based access to parameters, wizards, and faults. Navigation buttons for using the menu Exciter Control buttons Run and Stop buttons Figure 2-4. Diagnostic Interface – Keypad Start/stop commands, regulator transfer commands, and regulator activation commands can be issued from the keypad. The keypad also includes meter displays indicating system conditions such as generator MW and MVARs, field current and voltage, and regulator balance. Diagnostic displays such as the alarm history display provide system information for maintenance and troubleshooting. 2-10 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Control Module The control module is a VME-style rack with boards cable connected to the I/O terminal boards. This rack is divided into three independently powered sections for the M1, M2, and C controllers. Each controller consists of control and I/O processor boards. If the rack contains only the M1 controller then it is a simplex control system; if the rack contains all three controllers then it is a redundant control system. The control and I/O processor boards are as follows: EX2100 User’s Guide GEH-6632 • Microprocessor-based Application Control Layer Module (ACLA) controller, with LAN Ethernet port • Microprocessor-based Digital Signal Processor (DSPX) controller • Exciter ISBus Board (EISB), with fiber-optic communication with the bridge feedback board • Exciter Main I/O Board (EMIO), with control of pilot relays and gating commands to the ESEL board • Exciter Selector Board (ESEL), with gate pulse distribution from the active controller to the EGPA. Chapter 2 Functional Description • 2-11 Simplex Control System The interconnections between the simplex control and the terminal boards, generator protection modules, and power supply are shown in Figure 2-5. Only one EPSM power supply is used but this can have both ac and dc supplies for increased reliability. Ethernet Data Highway to Mark VI, LCI, and HMI Control Module M1 PT PT 3-phase Current Sensing CT EPCT Contact Inputs 41 close 41 Device Deexcitation 53B pilot 41 trip Crowbar 70 V dc De-ex pilot EISB CT 53A pilot ESEL PT To Flashing panel EXTB EMIO Master I/0 PT ACLA Computer (Tool) 3-phase Voltage Sensing DSPX Keypad 125 Vdc TRIP 86 Gate Pulse Amplifier 2nd TRIP Contact Outputs EGPA 70 Vdc To SCRs 125Vdc Fiber-optic Feedback ECTB 70 Vdc EPSM Power Supply 5 Vdc 15 Vdc 24 Vdc EGDM Field Ground Detector GPA power EPDM 125 V dc Battery 125 Vdc Option: DACA Rectified ac Field Current & Voltage EDCF EACF PPT and air core CT ac feedbacks EXAM Coil Power EDEX Deexcitation Optional: Crowbar Figure 2-5. Simplex Control and Cabling to Terminal Boards 2-12 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Redundant Control System A redundant control system has three controllers and three redundant power supplies, one for each controller. The power supply rack also holds three ground detector modules. Figure 2-6 shows three EDCF boards, and there can be three EPCT boards, if required. Up to two Ethernet cables are connected to the ACLA controllers (one to M1 and one to M2) for redundant communication with the turbine control and HMIs. Two keypads are shown connected to M1 and M2. Both keypads have access to the information in controller C. Ethernet Data Highway to Turbine Control and HMI To Flashing panel 53A pilot 41 close 53A pilot 41 close 53A pilot 41 close 53B pilot 41 trip 53B pilot 41 trip 53B 70V pilot 41 trip 70V 41 Device Deexcitation Option: Field Breaker DSPX ACLA DSPX EISB Bridge 2 TRIP Bridge 4 Tool 2nd Bridge 6 86 Bridge 1 TRIP EXTB EISB ESEL EISB EPCT EMIO Master I/0 CT ESEL CT EMIO Master I/0 Fan-out circuits Bridge 3 PT C M2 Bridge 5 PT M1 DSPX PT ACLA PT Keypad EBKP Backplane EMIO Master I/O Keypad Crowbar De-ex pilot -125Vdc Gate Pulse Amplifiers EGPA 125Vdc EGPA 125Vdc EDCF ECTB Fiber-optic Field V & I feedback 70V 70V P24V 70V P24V PN24V E G D EPSM M EPSM Power Power Supply Supply PN24V EPBP back plane E G D M 70V P24V PN24V EPSM Power Supply EPDM EDCF E G D M PPT and air core CT (AC) Feedbacks EACF 125 Vdc Coil Power GPA power Field Ground Detector EGDM 125 V dc Battery EDCF EDEX De-excitation EXAM Attenuator Optional: Crowbar Option: DACA Rectified ac Figure 2-6. Redundant Control System Cabling EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-13 Controller C Controller C is only used with redundant systems. It is mounted in the control rack and is physically similar to the M1 and M2 controllers, however, C is not responsible for bridge firing and therefore does not contain an ESEL, or ACLA board. Controller C receives the same feedback voltage and current inputs as the other controllers and contains similar software. Its purpose is to monitor the active and backup controllers (M1 or M2) and initiate appropriate protective responses in the event the system conditions exceed the defined regulation boundaries. Input and output signal voting takes place in all three controllers, which are linked in a Triple Modular Redundant (TMR) controller configuration. Each controller contains up to six boards, interconnected through the backplane as shown in the simplified diagram of Figure 2-7. Ethernet Data Highway (EGD, Modbus) To plant controls Serial Modbus Serial Modbus ACLA M1 DSPX M1 I/O I/O DSPX M2 DPM Communication across backplane ACLA M2 I/O DSPX C DPM ISBus Figure 2-7. Communication between Redundant Control Boards Control Power Supplies Redundant supplies provide high reliability. Power for the controls come from the Exciter Power Distribution Module (EPDM). This is supplied by a 125 V dc source and one or two 115 V ac sources. The ac source is passed through an ac/dc converter (DACA) as shown in Figure 2-8. The resulting 125 V dc is diode coupled with the other dc sources to create a dc bus that feeds the control modules and gate pulse amplifier boards. Fused outputs from the EPDM feed power to the EGPA boards, EXTB, and the Exciter Power Backplane (EPBP). Each output has an LED indication and an on/off isolation switch. The EPDM mounts on the left side of the Exciter Power Supply rack. Up to three Exciter Power Supply Modules (EPSM) mount in the EPBP backplane and provide logic level power to the controller(s). The EPSMs are fed by 125 V dc from the EPDM, and generate supply voltages of +5 V dc, ±15 V dc, and +24 V dc. In 2-14 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide addition there is an isolated 70 V dc output for use by EXTB and ECTB for contact wetting. Up to three ground detection modules (EGDM) are also mounted in the EPBP, as shown in Figure 2-9. These communicate with the EXAM module, which is located in the auxiliary cabinet. Exciter Power Distribution Module (EPDM) N125V P125V TB1 1 2 P125 FU2 3 4 5 125 V dc Filter FU4 AC1 Hot 7 JDACA1 SW3 10 10 9 9 2 12 12 J91 3 AC1 Neu. 21 DS4 G 115 Vac DACA #2 AC2 Hot JDACA2 1 22 7 1 Filter 23 115 Vac 9 3 DS5 G 10 J1M2 FU9 8A 9 FU10 1 SW5 2 DS6 G 1 8A 12 24 2 SW4 8A 10 3 8A FU8 3 J1C FU11 12 8A FU12 AC2 Neu. SW6 8A BJS jumper is supplied for isolation of ground reference on systems with external reference R1 To EGPA2 To EGPA3 To EXTB J1M1 FU7 JDACA2 7 To EGPA1 1 DS3 G 3.15A 115 Vac 3 J8C 3.15A FU6 1 2 FU5 7 1 1 18 SW2 DS2 G 3.15A 115 Vac DACA #1 17 2 J8B FU3 JDACA1 Filter SW1 3.15A N125 16 1 DS1 G 3.15A 6 15 J8A FU1 3.15A DS7 G 2 1 To EPSM1 To EPSM2 To EPSM3 R2 BJS Chassis Ground Figure 2-8. Exciter Power Distribution Module EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-15 Power to Exciter Backplane EBKP (Control Rack) To M1 M2 M1 EDEX EDCF To M2 EDEX EDCF CONTROL C EDEX EDCF CONTROL CONTROL EDEX EDEX J602 To C J602 EETB EDEX J602 EETB EETB ECTB ECTB ECTB EXTB Exciter Power EDEX EGDM FAN MEDIA Distribution CROWBAR CONV Module EPDM Fan EXTB EDEX EGDM FAN MEDIA CONV CROWBAR EXTB EDEX EGDM FAN MEDIA CONV CROWBAR J1C EPSM Power Supply M1 Blank plate Fan Fan J1M2 EPSM Power Supply M2 EGDM Ground Detector M1 EPSM Power Supply C EGDM Ground Detector M2 EGDM Ground Detector C J1M1 J1_M2 J1_M1 To J1M1 To J1M2 J1_C J2C GROUND DETECT To J1C 125 V dc 115 V ac Supplies Figure 2-9. Exciter Power Backplane (EPBP) with EPDM, Power Supplies & Ground Detector Modules 2-16 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Exciter Software The exciter software is configured and loaded from the toolbox, and resides in the controllers. The software is represented on the toolbox screen by control blocks linked together to show the signal flow. Figure 2-10 is a simplified overview of the exciter control system displaying the main control functions. Both the generator field and stator currents and voltages are measured and input to the control system. In normal operation the ac regulator is selected. Figure 2-11 is the simplified software block diagram displaying the main control blocks. The generator voltages and currents from the PTs and CTs are wired to the EPCT board, which acts as a signal conditioner to isolate and scale the signals. The conditioned signals are then fed to the controller. Software conversion algorithms use these signals to calculate system variables for use by the regulator, limiter, and protection functions. The outputs from these software calculations include the following: EX2100 User’s Guide GEH-6632 • Generator voltage magnitude and generator frequency derived from the PTs • The magnitude of generator current derived from the CTs • Generator power, P • Generator reactive volt amperes (VARs), Q • Change in rotor speed calculated from the integral of accelerating power that is normally used as the input to the optional Power System Stabilizer (PSS) • Generator active and reactive current • Magnitude of generator flux (VHz) • Line voltage derived from the PTs • Line frequency derived from line PTs • Phase angle correlation between the generator and line, derived from generator and line PTs Chapter 2 Functional Description • 2-17 Voltage/Current Sensing DC Regulator DC Voltage adjust Exciter Bridge Generator AC Regulator AC Voltage adjust Exciter System Stabilizer Circuits Over-excitation Limiter Under-excitation Limiter V/Hz Limiter & Protection VAR/Power Factor Control Voltage Sensing & Load Compensation Power System Stabilizer Figure 2-10. Control Scheme 2-18 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide External Raise/ Lower Reactive Current AUTO REF EXASP Setpoint Watts Slip Exciter AVR Setpoint. V/Hz Limit; Reactive Current Compensation. PSS Power System Stabilizer AVR Setpoint and Tracking Frequency Watts AVR VMAG UEL VARs Under Generator Excitation Terminal Limit Voltage (VMAG) VMAG Automatic Voltage Regulator FVR Track Value Setpoint FVR External Raise/ Lower Field Voltage Regulator Setpoint MANUAL REF Field Voltage Regulator Min. Field Volts from Bridge Output FCR Setpoint (User Input) Field Current from Bridge DC Shunt Firing Commd to Bridge FCR Field Current Regulator Figure 2-11. Software Block Diagram The output of the control software is the firing command, which is sent to the bridge to generate the field current. The individual function blocks are discussed in the following sections. EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-19 Auto Reference – AUTO REF The AUTOREF block generates an auto (or Auto Control (AC)) setpoint for the Automatic Voltage Regulator (AVR) based on user-supplied parameters and conditions. Raise/lower inputs to AUTO REF come in from the other devices on the Data Highway such as the turbine control or HMI. A variable rate integrator generates the output setpoint within preset limits. The setpoint is combined with other auxiliary stabilizing and protective signals in the EXASP block to form the reference to the AVR block. AVR Setpoint – EXASP The EXASP block combines a number of functions to produce the setpoint (reference input) to the AVR, and the AVR tracking value. The EXASP inputs are as follows: • Stabilizing signal from the PSS block • Output from the AUTOREF block • External test signal • Protective signal generated by the UEL block • Reactive current input (feedback) • Voltage magnitude input (feedback) • Frequency input (feedback) The outputs to the AVR block are the AVR setpoint and tracking value. Automatic Voltage Regulator – AVR Generator terminal voltage is controlled by the AVR. The AVR block maintains the generator terminal voltage. The setpoint (reference) comes from the EXASP block, and the feedback is the generator voltage. The error value is input to a proportional plus integral (PI) regulator with integrator windup protection, which produces an output signal. Figure 2-12 shows the block diagram. When the AVR is enabled, the AVR output is passed through directly from the track input to the output of the Field Voltage Regulator (FVR). 2-20 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Preset Condition S Preset State True Q Q Preset Not True R 0.05 a b a>b? Proportional Gain Enable Software Jumper 0 Q Software Jumper 1 Output Value 1 Gain Scaling AVR Setpoint + Integral Gain Error Tracking Control Preset State 1 s Σ - Generator Voltage Σ - Status of Regulators Antiwindup + + Σ Output Negative Limit Integrator Tracking Input + Positive Limit Integration Output Tracking Gain r/s AVR Status Preset Value + Σ - Figure 2-12. Automatic Voltage Regulator Block Manual Reference – MANUAL REF The MANUAL REF block generates a manual setpoint for the FVR or FCR based on user-supplied parameters and conditions. Raise/Lower inputs to MANUAL REF come in from other control devices on the Data Highway such as the turbine control or HMI. Field Voltage and Current Regulators - FVR & FCR The Field Voltage Regulator (FVR) is the typical manual regulator supplied on most applications and uses the generator field voltage as the feedback input. While FVR does permit the current to vary as a function of the field resistance, the FVR makes the manual regulator completely independent from the over excitation limiter. FVR uses the voltage from the generator field as feedback, with a setpoint from the MANUAL REF block. A PI regulator with integral windup protection generates the output. During operation in AVR mode, the output of the AVR is passed directly to the FVR output with no signal conditioning. On units that operate with an inner field EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-21 voltage regulator loop such as compound exciters and some high ceiling exciters, the FVR uses a setpoint from either the AVR or the MANUAL REF block, and is always operational whether in manual or automatic operation. The Field Current Regulator (FCR) is a special application of the manual regulator and uses the generator field current as the feedback input. The current setpoint is generally switched between a high level and lower level to provide transient forcing capability as well as steady state operation within the capability of the generator. Generally the setpoint is larger than expected field currents and the integral preset is operational. The FCR output is held at positive ceiling until enable becomes true which allows the output to follow the P+I regulator. The bridge firing command is the smaller of the FVR and FCR outputs. While it does regulate constant field current over varying field temperature, FCR is not the standard manual regulator. Under Excitation Limiter – UEL The UEL block is an auxiliary control to limit the automatic voltage regulator demand for underexcited reactive current (or reactive power). UEL prevents reduction of the generator excitation to a level where the small-signal (steady state) stability limit, or the stator core end-region heating limit is exceeded. Performance is specified by identifying the region of limiter action on the generator capability curve. There is both a setpoint section and regulator section of the UEL. The two key inputs are generator terminal voltage and real power. Power System Stabilizer – PSS The PSS block provides an additional input to the automatic regulator to improve power system dynamic performance. A number of different quantities may be used as inputs to the PSS, such as shaft speed, frequency, synchronous machine electrical power, accelerating power, or some combination of the above. The PSS used with the exciter is multi-input using a combination of synchronous machine electrical power and internal frequency (which approximates rotor speed) to arrive at a signal proportional to rotor speed. This comes from the integral of accelerating power, but with shaft torsional signals greatly attenuated. The input signal is derived entirely from generator terminal quantities without the need for shaft speed transducers. No additional external hardware is required. 2-22 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Operator Interface The HMI contains exciter and turbine graphic displays. Operator and engineering work stations such as the HMI (Human Machine Interface) and the toolbox communicate with the exciter. This allows operator monitoring and control of the exciter, and engineering access to system diagnostics and control block configuration Turbine Control HMI An HMI can be mounted in a control console or on a tabletop. On turbine generator sets that include Mark VI turbine controls, the exciter shares the HMI. The HMI is Windows NT® based with CIMPLICITY operator display software and communication drivers for the data highways. From the HMI, the operator can initiate commands and view real-time data and alarms on the CIMPLICITY graphic displays. An HMI can be configured as a server or viewer, and can contain tools and utility programs. Redundant cable operation is optional and, if supplied, operation continues even if one cable is faulted. The Unit Data Highway (UDH) connects the exciter with the HMI or HMI/Data Server. The network is 10BaseT Ethernet, and uses separately powered network switches. For longer runs, fiber-optic cables can be used. Control System Toolbox (toolbox) The toolbox is used to configure and maintain the exciter. Control blocks and diagrams can be modified by configuration and loaded into the control. With the exciter online, real-time data is available on the toolbox screen, including control system diagnostics for troubleshooting. The toolbox software runs on an HMI server or a separate PC on the UDH. Direct connection to the controller DSPX board is also possible through the Tool port on the control rack backplane. EX2100 User’s Guide GEH-6632 Chapter 2 Functional Description • 2-23 Notes 2-24 • Chapter 2 Functional Description GEH-6632 EX2100 User’s Guide Chapter 3 Printed Wiring Boards Overview Introduction This chapter describes the EX2100 printed wiring boards and their operation. These boards fall into four functional groups; control rack boards including controller boards and I/O processors, I/O terminal boards, bridge control and protection modules, and power supply boards. This chapter is organized as follows: Section Page Control Boards......................................................................................................... 3-2 EBKP Backplane .............................................................................................. 3-2 DSPX Board ..................................................................................................... 3-2 ACLA Board..................................................................................................... 3-4 EISB Board....................................................................................................... 3-4 EMIO Board ..................................................................................................... 3-4 ESEL Board...................................................................................................... 3-4 I/O Terminal Boards ................................................................................................ 3-5 EPCT Board...................................................................................................... 3-5 ECTB Board ..................................................................................................... 3-5 EXTB Board ..................................................................................................... 3-5 EDCF Board ..................................................................................................... 3-6 EACF Board ..................................................................................................... 3-6 Bridge and Protection Boards and Modules............................................................. 3-7 EGPA Board ..................................................................................................... 3-7 EXCS Board ..................................................................................................... 3-7 EDEX Board..................................................................................................... 3-7 EGDM Module ................................................................................................. 3-7 EXAM Module ................................................................................................. 3-8 Power Supply Boards............................................................................................... 3-9 EPDM Module.................................................................................................. 3-9 EPBP Backplane............................................................................................... 3-9 EPSM Module .................................................................................................. 3-9 DACA – Ac to Dc Converter.......................................................................... 3-10 Related Board Publications.................................................................................... 3-11 EX2100 User’s Guide GEH-6632 Chapter 3 Printed Wiring Boards Overview • 3-1 Control Boards The control boards are located in the control module. This module consists of the exciter backplane (EBKP) and the metal chassis that holds the boards (refer to Figure 3-1). The control boards are as follows: • IS200DSPX Digital Signal Processor control board (DSPX) • IS215ACLA Application Control Layer Module (ACLA) • IS200EISB Exciter ISBus Board (EISB) • IS200EMIO Exciter Main I/O board (EMIO) • IS200ESEL Exciter Selector board (ESEL) EBKP Backplane The EBKP provides the backplane for the control boards and the connectors for the I/O terminal board cables. EBKP has three sections for controllers M1, M2, and C. Each section has its own independent power supply. Controllers M1 and M2 have the ACLA, DSPX, EISB, EMIO, and ESEL boards. Section C only has the DSPX, EISB, and EMIO. Two overhead fans cool the controllers. The upper part of the backplane contains DIN connectors for the plug-in control boards. The lower part of the backplane contains D-SUB connectors for I/O interface cables, and circular DIN connectors for keypad interface cables, power supply plugs, and test rings. Labels on the connectors in Figure 3-1 refer to the boards and devices to which the cables are connected. For more information refer to Chapter 4 and GEI100460. DSPX Board The DSPX performs most of the I/O interface and inner loop bridge control and protection functions The DSPX board is the main controller and shares control responsibility with the ACLA. It is a single-slot, 3U high module located in the control rack next to the ACLA. It provides functions including the bridge firing circuit control, I/O processing, and inner loop regulation as follows: • Field Voltage Regulator (FVR) • Field Current Regulator (FCR) • SCR gating signals to the ESEL board • Start-stop function • Field flashing control • Alarms and trip logic • Generator instrumentation processing • Generator simulator For more information refer to Chapter 4 and GEI-100267. 3-2 • Chapter 3 Printed Wiring Boards Overview GEH-6632 EX2100 User’s Guide Fan Fan RST RST OK ACTIVE ENET FLASH OK ACTIVE ENET FLASH S T A T U S S T A T U S DSPX EISB EMIO ESEL ESEL EMIO 2 1 2 1 ACLA DSPX ACLA DSPX EISB EISB J304 J305 J306 J307 J308 J309 E P C T Keypad M1 Tool M1 E G P A 1 E G P A 2 J314 J315 E P C T Keypad M2 Keypad C Tool M2 Tool C E P C T J404 J405 J406 J407 J408 J409 E C T B Test Rings M1 E G P A 3 E G P A 4 J414 J415 E C T B J612 J514 J515 E A C F 1 2 J610 10 4 3 3 M2 Power 4 3 1 IS200EBKPG1AAA E A C F 2 1 1 2 E X T B 10 E G P A 6 1 1 2 E G P A 5 3 M1 Power 1 10 J602 E X T B 2 1 3 2 1 E A C F E C T B Test Rings M2 Test Rings C M1-Fan Pwr M2-Fan Pwr C-Fan Pwr J504 J505 J506 J507 J508 J509 J510 J502 J512 4 3 EMIO E X T B C Power Figure 3-1. Control Module EX2100 User’s Guide GEH-6632 Chapter 3 Printed Wiring Boards Overview • 3-3 ACLA Board ACLA handles network communications and outer loop functions. The ACLA board is a double-slot, 3U high module located next to the DSPX. ACLA provides Ethernet communications with the turbine control, LCI, and HMI, and runs outer loop control functions including the following: • Automatic Voltage Regulator (AVR) • Power System Stabilizer (PSS) • Under Excitation Limit control (UEL) • VAR/power factor regulator (VAR/PF) For more information refer to Chapter 4 and GEI-100434. EISB Board EISB manages all the fiberoptic communication in the cabinets. The Exciter ISBus Board (EISB) is a special communication interface board for the M1, M2, and C control modules. ISBus is a proprietary, high-speed communication bus used in many GE systems. The EISB is used to provide communication among the 3 DSPSs in M1, M2, and C. EISB receives and transmits fiber-optic feedback signals through the backplane connector. It transmits them over the control backplane to the DSPX controller and also communicates between the DSPX and the tool and keypad ports using RS-232C. EISB is a single-slot, 3U high module that is located in the control rack under the DSPX. From six fiber-optic connectors on the front panel it accepts current and voltage signals from the generator field (and from the exciter if required) using EDCF boards, and receives and transmits signals to the Ground Detection Module (EGDM). For more information refer to Chapter 4 and GEI-100454. EMIO Board The EMIO is a single slot, double height VME style board, that manages the I/O from the EPCT, ECTB, EACF, and EXTB terminal boards. The I/O include PT and CT signals, contact inputs, output relay drivers, and pilot trip relay drivers. It also sends logic level gate pulse signals over the backplane to the ESEL board, which sends them to EGPA in the power conversion cabinet. For more information refer to Chapter 4 and GEI-100453. ESEL Board The Exciter Selector board receives six logic level gate pulse signals from its corresponding EMIO. These pulse signals drive up to six sets of cables which are distributed to the exciter gate pulse amplifier (EGPA) boards. The EGPA boards are mounted in the power conversion cabinet. If there are redundant controls, two ESEL are used, one driven by M1 and the other by M2. The active ESEL, selected by controller C, sends the necessary control signals to the EGPA boards. Three groups of ESEL boards are available supporting increasing redundancy levels; ESELH1 contains a single bridge driver, ESELH2 contains three bridge drivers, and ESELH3 contains six bridge drivers. For more information refer to Chapter 4 and GEI-100456. 3-4 • Chapter 3 Printed Wiring Boards Overview GEH-6632 EX2100 User’s Guide I/O Terminal Boards The exciter terminal boards are as follows: • IS200EPCT Exciter PT/CT board (EPCT) • IS200ECTB Exciter Contact Terminal Board (ECTB) • IS200EXTB Exciter Terminal Board (EXTB) • IS200EDCF Exciter Dc Feedback board (EDCF) • IS200EACF Exciter Ac Feedback board (EACF) EPCT Board EPCT receives and conditions generator PT and CT feedbacks. The EPCT contains isolation transformers for critical generator voltage and current measurements. Two three-phase generator PT voltage inputs are input to EPCT. Two generator CT current inputs, with current levels of 1 A or 5 A, are input. In addition, one analog input, which can be either 0-10 V or 4-20 mA, is brought into EPCT. All the signals are interfaced to the EMIO board. For more information refer to Chapter 4 and GEI-100459. ECTB Board The ECTB board supports excitation contact outputs and contact inputs. There are two versions; the ECTBG1 board which is only used in the redundant mode, and the ECTBG2 board which is only used in the simplex mode. Each board contains two trip contact outputs driving a customer lockout, and four general purpose Form-C relay contact outputs, controlled by the EMIO board. Six auxiliary contact inputs are powered (wetted) with 70 V dc by ECTB. Also, the 52G and 86 G contact inputs are powered and monitored by ECTB. In the redundant case, power comes from the M1 and M2 power supplies. For more information refer to Chapter 4 and GEI-100457. EXTB Board EXTB handles field flashing and protection functions. The EXTB board supports pilot relay contact outputs, contact inputs, and signal conditioning circuits. EXTB cables to the EMIO board through the EBKP backplane. Pilot relays for the breaker/contactor close 41, and flashing contactors 53A, and 53B are located on the board, plus pilot relays for the trip relay 41T and the de-excitation relay KDEP. Crowbar status signals and de-excitation status signals from the EDEX board are conditioned on EXTB and sent to EMIO. Three contact inputs from 41, 53A, and 53B are powered (wetted) by 70 V dc on EXTB. Power for the contacts is from the M1 and M2 power supplies (redundantly), and the resulting status signals are sent to EMIO in the control rack. Different groups of EXTB are available for controlling either a field breaker or a contactor in the field circuit. These groups are defined in Table 3-1. For more information refer to GEI-100458. Table 3-1. EXTB Board Groups Trip Relay 41T used Close Relay 41 used Contactor Mode No Yes EXTB G3 Breaker Mode Yes Yes Simplex control EXTB G2 Contactor Mode No Yes Simplex control EXTB G4 Breaker Mode Yes Yes Type of Redundancy Board Control Mode Redundant control EXTB G1 Redundant control EX2100 User’s Guide GEH-6632 Chapter 3 Printed Wiring Boards Overview • 3-5 EDCF Board EDCF handles bridge dc voltage and current feedback. The EDCF board measures field current and field voltage at the SCR bridge, and interfaces to the EISB board in the control panel over a high-speed fiber-optic link. The fiber-optics provides voltage isolation between the two boards, and high noise immunity. Field current is measured using a shunt in the dc field circuit. The field voltage feedback circuit provides seven selector settings to scale down the bridge voltage, depending on the type of bridge application. For more information refer to Chapter 4 and GEI-100464. EACF Board EACF handles bridge ac voltage and current feedback. The EACF board measures the exciter PPT ac supply voltage and current. The EACF terminal board contains transformers for a 3-phase voltage measurement, and terminals for two Flux/Air core coils. The outputs of the voltage and current circuits are fanned out to three DB9 connectors for cables to controllers M1, M2, and C. These cables can be up to 90 m in length. There are two versions of this board, EACFG1 is for inputs up to 480 V rms, and EACFG2 is for inputs up to 1000 V rms. For more information refer to Chapter 4 and GEI-100465. 3-6 • Chapter 3 Printed Wiring Boards Overview GEH-6632 EX2100 User’s Guide Bridge and Protection Boards and Modules The exciter bridge and protection boards are as follows: • IS200EGPA Exciter Gate Pulse Amplifier board (EGPA) • IS200EXCS Conduction Sensor board (EXCS) • IS200EDEX Exciter De-Excitation board (EDEX) • IS200EGDM Exciter Field Ground Detector Module (EGDM) • IS200EXAM Exciter Attenuator Module (EXAM) • Crowbar module EGPA Board Bridge control passes through EGPA. One EGPA is required per PCM. The EGPA board interfaces the control to the power bridge. EGPA takes the six gate commands from the ESEL and controls the gate firing of up to six SCRs on the bridge. It is also the interface for current conduction feedback, and the bridge airflow and temperature monitoring. A nominal 125 V dc power source from EPDM supplies an on-board dc/dc converter that provides power for SCR gating over the full range of input supply voltage. LEDs provide visual indication of the status of the output firing, currents into the bridge, gate power supply, line filter, cooling fan rotation, and bridge temperature and alarm or fault conditions. For more information refer to Chapter 4 and GEI-100461. EXCS Board The EXCS board has four conduction sensors. It is used to detect the presence of current in the bus. The output is a logic signal. EDEX Board EDEX is usually controlled by EXTB, but can initiate deexcitation if control fails. The EDEX board is the main board in the de-excitation module. EDEX provides deexcitation SCR firing, conduction sense feedback, and voltage retention to ensure operation in the event of a power failure. EMIO initiates de-excitation on the EXTB board. The EXTB board opens the 41 dc contactor (41A/41B) or breaker, and then transfers de-excitation signals from the auxiliary contacts to SCR firing circuits on the EDEX. There are two types of EDEX. Group 1 board is designed for SCR deexcitation, Group 2 is designed for diode de-excitation. For more information refer to Chapter 4 and GEI-100466. EGDM Module EGDM and EXAM work together to detect field ground leakage current. EX2100 User’s Guide GEH-6632 The EGDM is a double slot, double height (6U) form factor board that mounts in the Exciter Power Backplane rack (EPBP). A simplex system has one EGDM, while a redundant system has three. EGDM detects field leakage resistance from any point in the field circuit of the generator to ground, either on the ac or dc side. The field ground detector applies a low frequency square wave to the sense resistor connected to the field circuit. EXAM, the attenuator module located in the Auxiliary Panel, senses the voltage across the ground resistor and sends the signal to the EGDM through a nine-conductor cable. Chapter 3 Printed Wiring Boards Overview • 3-7 In a redundant system, the set of three EGDM boards are configured as a Controller (C), Master 1 (M1) and Master 2 (M2). The configuration for each EGDM is controlled by a set of program pins on the P2 connector. The C controller receives information from the active DSPX on which EGDM master should provide the drive signal to the sense resistor in the Attenuator Module. The active master receives an Oscillator Signal over the fiber optic link that it converts to a ±50 V signal. This is applied to one end of the sense resistor in the Attenuator Module. The signal conditioner receives an attenuated (10:1) differential signal from the Sense Resistor. This is a simple unity gain differential amplifier with a high common-mode rejection ratio followed by an A-to-D converter (Voltage Controlled Oscillator VCO). This feeds a fiber-optic transmitter that is cabled to EISB. The signal conditioner circuitry is powered by an isolated power supply to maintain personnel and equipment safety due to the high common-mode voltage at the Sense Resistor. For more information refer to Chapter 4 and GEI-100467. EXAM Module The EXAM mounts in the auxiliary cabinet and contains a sense resistor connected to a resistor network across the field. EXAM applies the low frequency ±50 V square-wave signal, supplied from the EGDM, to one end of the sense resistor. The resulting current generates a voltage across the resistor, that is sent back to the EGDM. In a redundant system, the test signal can come from either, M1 or M2. EXAM has a relay that switches between the two under the control of controller C. A single cable carries the control and sense signals between the EGDM and EXAM modules. For more information refer to Chapter 4 and GEI-100467. 3-8 • Chapter 3 Printed Wiring Boards Overview GEH-6632 EX2100 User’s Guide Power Supply Boards The exciter power supply boards are as follows: • IS200EPDM Exciter Power Distribution Module (EPDM) • IS200EPBP Exciter Power Backplane (EPBP) • IS200EPSM Exciter Power Supply Module (EPSM) • DACA Module EPDM Module The EPDM provides the power for the control, I/O, and protection boards. It is mounted on the side of the EPBP and accepts a 125 V dc supply from the station battery, and one or two 115 V ac supplies. All supply inputs are filtered. Each ac supply is rectified to 125 V dc in an ac to dc converter (DACA). The resulting two or three dc voltages are diode coupled together to create the dc source supply, designated as P125V and N125V. With the center grounded, these voltages are nominally +62.5 V and –62.5 V to ground. Any of the exciter power supply modules can be switched off from the EPDM. Individual supply outputs to the exciter boards are fused. They have an on/off toggle switch, and a green LED indicator to display supply power availability. These outputs supply up to three EGPA boards, the EXTB board, and three EPSM modules serving the three controllers. Outputs are wired to the EPBP for distribution. For more information refer to Chapter 4. EPBP Backplane The EPBP holds three electrically isolated power supplies (EPSM) that supply power to the M1, M2, and C controllers. It also holds three EGDM. EPBP accepts 125 V dc from the adjacent EPDM, and distributes logic level power from the three EPSM to the three controllers. Each power supply has an independent ON-OFF switch on the EPDM. The EPSM modules interface to the backplane through DIN connectors. 70 V dc and 24 V dc power is distributed from the locking connectors at the top of the backplane to the terminal boards. Refer to Figure 3-2. For more information refer to Chapter 4 and GEI-100463. EPSM Module The EPSM converts 125 V dc from the EPDM into the voltages required for the control system. There are three independent power supplies that supply power to each of the controllers M1, M2, and C. These supplies are located in the power supply module mounted below the control rack in the control cabinet. The EPSM supplies +5 V dc, ±15 V dc, and +24 V dc to the controller. Power is also supplied to modules external to the control rack as follows: • ±24 V dc to power the EDEX de-excitation module, crowbar module, EGDM, and EDCF • Isolated +70 V dc for contact wetting to the EXTB and ECTB boards For more information refer to Chapter 4 and GEI-100462. EX2100 User’s Guide GEH-6632 Chapter 3 Printed Wiring Boards Overview • 3-9 M2 M1 EDEX EDCF CONTROL J17 J16 EDEX M1 M1 J602 EETB J15M1 ECTB J13M1 J18 M1 J19 M1 J20 M1 J21M1 J15M2 ECTB J13M2 EXTB J12M2 J18 M2 J20 M2 J21M2 J15C ECTB J13C EXTB J12C J18 C J19 C J20 C J21C EPSM J14C BARCODE J1_C EGDM P217 P213 J2C J1_M2 P117 P113 EGDM P211 P207 P205 P201 IS200EPBPG1 EPSM EDEX EDCF CONTROL J17 J16 EDEX C C J602 EETB EDEX EGDM FAN MEDIA CONV CROW BAR P111 EGDM P107 EPSM J19 M2 J14M2 EDEX EGDM FAN MEDIA CROW CONV BAR P105 P101 J1_M1 EDEX EDCF CONTROL J17 J16 EDEX M2 M2 J602 EETB EXTB J12M1 EDEX EGDM FAN MEDIA CONV CROW BAR Blank plate J14M1 C GROUND DETECT Figure 3-2. Exciter Power Backplane DACA – Ac to Dc Converter The DACA is an ac to dc converter that is powered by a 115 V ac source and produces 125 V dc. The DACA and battery source provide a redundant 125 V dc supply for the EPDM. Two DACAs can be connected to the EPDM if required for greater power supply reliability. 3-10 • Chapter 3 Printed Wiring Boards Overview GEH-6632 EX2100 User’s Guide Related Board Publications For a more detailed description of each board's circuitry and application data, refer to the following documents: EX2100 User’s Guide GEH-6632 • GEI-100460 IS200EBKP Exciter Backplane • GEI-100267 IS200DSPX Digital Signal Processor Board • GEI-100434 IS215ACLAH1 Application Control Layer Board • GEI-100454 IS200EISB Exciter ISBus board • GEI-100453 IS200EMIO Exciter Main I/O board • GEI-100456 IS200ESEL Exciter Selector board • GEI-100459 IS200EPCT Exciter PT/CT board • GEI-100457 IS200ECTB Exciter Contact Terminal Board • GEI-100458 IS200EXTB Exciter Terminal Board • GEI-100464 IS200EDCF Exciter DC Feedback board • GEI-100465 IS200EACF Exciter AC Feedback board • GEI-100461 IS200EGPA Exciter Gate Pulse Amplifier board • GEI-100466 IS200EDEX Exciter De-Excitation board • GEI-100467 IS200EGDM Exciter Ground Detector Module • GEI-100463 IS200EPBP Exciter Power Backplane • GEI-100462 IS200EPSM Exciter Power Supply Module Chapter 3 Printed Wiring Boards Overview • 3-11 Notes 3-12 • Chapter 3 Printed Wiring Boards Overview GEH-6632 EX2100 User’s Guide Chapter 4 Terminal Board I/O and Equipment Connections Introduction This chapter describes the customer's equipment connections, and inputs and outputs (I/O) available through terminal board wiring. System cabling to provide desired functionality is also defined. The information is organized as follows: Section Page Power Connections and Analog I/O......................................................................... 4-2 Power Potential Transformer Inputs ................................................................. 4-3 Potential and Current Transformer Inputs ........................................................ 4-3 Analog Input ..................................................................................................... 4-3 Customer Contact I/O .............................................................................................. 4-4 Power Supply Inputs ................................................................................................ 4-6 Line Filter Connections............................................................................................ 4-7 Exciter Internal I/O .................................................................................................. 4-8 Exciter AC Feedback ........................................................................................ 4-8 Exciter DC Feedback ........................................................................................ 4-8 De-Excitation ......................................................................................................... 4-11 Crowbar ................................................................................................................. 4-14 Field Ground Detector ........................................................................................... 4-14 Field Flashing ........................................................................................................ 4-16 Dc Field Flashing Settings.............................................................................. 4-16 Flashing Control Sequence ............................................................................. 4-16 Shaft Voltage Suppressor....................................................................................... 4-18 Data Highway Connections ................................................................................... 4-19 Control System Toolbox Connection..................................................................... 4-20 EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-1 Power Connections and Analog I/O Figure 4-1 displays a typical connection diagram of the common power and analog I/O for an excitation system. Customer Supplied + Generator Field + To Bridge 1 - Control Cabinet Generator Field 1 2 PT1 3 H1 P PTSW1 (O X1 SE PE N RI C O H2 VAVA RG X2 C: R C:O H3 1412 UN X3 400 D E 0 D 1 2 TB1 3 4 2 4 6 5 6 8 10 Y) PT2 PTSW2 (O X1 H1 P SE PE N RI C 2 3 4 14 16 O R H2 VA VA G X2 C :C : RO H3 1412 UN X3 400 D E 0 D Power Flow 12 1 18 20 6 5 22 24 Y) CTSW1 2 4 4 PPT 41AC1 X1 P SE RI C X2 H2 KV VA VA A C: C :X3 H3 12 12 65 80 47 0 0 Phase Rotation 3 1 L1 K1 L2 K2 L3 K3 PT PT PT PT 5 7 9 11 J3 05 13 15 17 Fa nou J3 08 t cir cui ts 19 21 23 1 1 5H 3 2 5L 1H 3 1L 4 CT J3 15 To EMIO (M1) To EMIO (M2) To EMIO (C) TB3 1 5H 1 3 2 3 4 H1 3 TB2 CTSW3 2 1 5L CT 1H 1L EPCT Power Conversion Cabinet To Bridge 1 Note: Circuits shown external to the exciter are for reference only. 2 Figure 4-1. Exciter AC Power Supply and PT/CT Wiring 4-2 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Power Potential Transformer Inputs In the EX2100 excitation system, a 3-phase source of ac power is converted to a controlled dc output. This ac input can be from one of several sources. Most common is a generator terminal connected Y-Delta power potential transformer. The primary and secondary voltages as well as kVA ratings are sized for the particular application. An auxiliary bus fed PPT is also commonly used. In industrial applications where forcing is needed for large motor starting a compound source (current and voltage) input can be used. This ac input is connected to the bus in the bridge cabinet and can be isolated by the 41AC1 device for maintenance. It is monitored by the controls through the EACF board. Potential and Current Transformer Inputs A redundant PT input for PT failure detection is possible, and single-phase sensing can be supported. Customer supplied 3-phase PT and CT are wired to switches in the control cabinet as shown in Figure 4-1. The switches are wired to the EPCT. High frequency noise suppression near the point of signal entry is provided on all input signals to EPCT. On the board, the two 3-phase generator voltage inputs, nominal 115 V ac, are brought into PT transformers. Two generator CTs (phases A and C), with either 1 A or 5 A secondaries, are brought into CT transformers. The resulting low voltage transformer output signals are cabled to the EMIO board in the control rack. Generator Voltage Measurement The cable lengths from the generator PTs can be up to 1000 ft of #12 AWG wire. The PT secondary outputs are nominally 115 V rms at 50/60 Hz and are fused. On EPCT, the two transformers make a three-wire open delta voltage measurement, yielding 1.533 V rms for a 115 V rms input. In the case of a simplex system the voltage signals are sent through the J305 connector to the EMIO board in the M1 controller. In the case of a redundant system, the signals are fanned to connectors J305, J308, and J315, and sent to controllers M1, M2, and C. Item PT Inputs CT Inputs Number of Inputs 2, 3 phases each 2, Phases A and C Volts or Current 10-200 V rms, 115 V rms nominal 0-2 A, nominal 1A, or 0-10 A, nominal 5 A Frequency 50/60 Hz nominal 50/60 Hz nominal Burden Less than 1 VA Circuit loading 6.25 VA nominal Generator Current Measurement Two generator current inputs from the CTs are wired to non-pluggable terminal blocks, TB2 and TB3 that support ring terminals. The CTs do not have fused secondaries. There is a choice of a 0-1 A rms CT input, or a 0-5 A rms CT input. The cable length from the CT to the EPCT board can be up to 1000 ft., and the wire gage can be up to #10 AWG. The resulting signals are sent to the EMIO board through the same connectors as the voltage signals. Analog Input The EPCT board provides an analog input for customer use. This input is jumper selectable for either ± 10 V dc or 4-20 mA. The EMIO samples the input at 2000 samples per second, and the accuracy is better than 1% full scale. EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-3 Customer Contact I/O Customer contact inputs and relay contact outputs are wired to the ECTB board. In addition to six general purpose contact inputs, there are two dedicated contact inputs, wetted by 70 V dc from the exciter, as follows: • 86G contact input used as a lockout during normal operation • 52G contact input gives the online status of the generator ECTB provides four general purpose Form C contact outputs controlled by EMIO. These are used for 94EX and 30EX and other outputs. For each relay, the coil current and the status of a relay auxiliary contact is monitored. These feedbacks are cabled to EMIO in the controller. Refer to Figure 4-2 and Table 4-1. Table 4-1. General Purpose Relay Contact Characteristics: Item Description Customer Power 125 V dc nominal (24 V dc min) Relay break characteristic Resistive load Inductive Suppression 2A 0.5 A 1A 0.1 A 28 V dc 125 V dc 28 V dc 125 V dc 0.007 s (L/R) 0.007 s (L/R) External suppression supplied by customer on induction loads ECTBG1 is the redundant control version of the ECTB. This fans inputs to three connectors J405, J408, and J418 that are cabled to the three controllers. For relay control, the board does two-out-of three voting, and the 70 V dc and 24 V dc inputs are redundant. 4-4 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide J13M1 ECTBG2 (Simplex) P70 V dc From M1 P24M1 TB1 P24D 18 NO P24D J405 Relay Driver COM Coil K#GP NC From M1 (EMIO) 19 Customer Power to Contacts 20 125 V dc Ex. Fault to Mark VI Four General Purpose Relay Outputs as Above 1 Relay Driver Coil K#M1 P24M1 M1 Customer Power to Contacts M1 5 125 V dc Two Trip Relay Outputs as Above Term. 1&5 Ex. trip to Customer 86 P70Vdc Red LED 33 34 Current Limit Circuit Six Circuits as Above Red LED P70Vdc Current Limit Circuit 45 46 P70Vdc 47 To Optocoupler on M1 (EMIO) Current Limit Auxiliary Contact Input 48 52G Contact (Closed online) 86G Contact (Open for Trip) TB2 Figure 4-2. Customer I/O wired to ECTBG2 Simplex Board EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-5 Power Supply Inputs The customer’s ac and dc power inputs are wired to the exciter’s Power Distribution Module (EPDM), which is located on the left hand side of the exciter power backplane rack. Figure 4-3 shows the screw terminals for the 125 V dc battery source, and the 115 V ac suply, AC1. A second ac supply, AC2, can also be connected. EPDM Exciter Power Distribution Module 125 V dc from battery N125Vdc N125Vdc N125Vdc x x x x x x 115 V ac supply #1 x x x x 115 V ac supply #2 AC2N AC2N x x 2 4 6 8 10 12 14 16 18 20 22 24 SPARE SW6 J1C 1 SW5 J1M2 1 SW4 J1M1 1 SW3 J8C SW2 J8B SW1 J8A TB1 x x x x x x x x x x x x x 1 3 5 7 9 11 13 15 17 19 21 23 P125Vdc P125Vdc P125Vdc AC1H AC1H AC1N AC1N AC2H AC2H x 1 SW7 2 2 2 2 1 2 1 2 1 2 1 J9 3 1 10 JDACA1 3 1 12 10 JDACA2 3 12 Figure 4-3. Power Wiring Connections to EPDM. 4-6 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Line Filter Connections The 600 V filter is connected to fuse board LFU1. The 1000 V filter has two filter circuits and is connected to fuse boards LFU1 and LFU2. The filters are located at the top of the auxiliary cabinet. Connections to the line filter are shown in Figure 44. Auxiliary Enclosure Linefilter EACF1 TB4 1 From PPT L1 L2 L1 L2 L3 DISC 1 1 Coil1_L 3 Coil2_H 4 Coil2_L TB3 J5 04 J5 04 EMIO M1 J5 09 J5 09 EMIO M2 J5 14 J5 14 EMIO C 4 F U2 3 6 F U3 5 2 F U1 1 480V : 1.6V L3 LFU1 LFU2 F U1 2 TB2 L1 L2 2 EKBP Rack Coil1_H TB1 L3 Control Enclosure 4 F U2 3 6 GND F U3 5 B-L1 To Warm Backup Bridge B2 GND on Aux Panel B-L2 B-L3 Figure 4-4. EX2100 User’s Guide GEH-6632 AC Feedback and Line Filters Chapter 4 Terminal Board I/O and Equipment Connections • 4-7 Exciter Internal I/O Exciter AC Feedback The EACF board measures the exciter ac supply voltage and current. The terminal board contains transformers for a 3-phase voltage measurement, and terminals for two flux/air core coils. The cable between EACF and the EBKP control backplane can be up to 90 m in length. Cable shield terminal screws attached to chassis ground are located within three inches of the input screws where applicable. There are two versions of the circuit board, EACFG1 for up to 480 V rms inputs, and EACFG2 for up to 1000 V rms inputs. Refer to Figure 4-4. Exciter DC Feedback The EDCF board measures field current and field voltage at the SCR bridge, and interfaces to the EISB board in the controller over a high-speed fiber-optic link. The fiber optics provides voltage isolation between the two boards, and high noise immunity. For a circuit block diagram, refer to Figure 4-5. The field voltage feedback circuit provides seven selector settings to scale down the bridge voltages appropriate to the application. EDCF DC Feedback Board +/-24Vdc from External Source 1 +24V -24V 2 3 + 24 V dc DC/AC Inverter AC/DC Converter & Power Supplies 4 - 24 V dc + 15 V dc - 15 V dc + 5 V dc J16 SCR Bridge COM 30 Vdc max. + Field Current Amplifier To EISB board Tx1 Fiber Optic Link Tx2 Shunt mV input - DC Shunt + - I feedbk ACOMH V feedbk Field Voltage Amplifier Voltage Isolation Barrier scale 7 scale 1 JP7 JP1 R9 Ra R1 - Field + Stab-on ACOMH Figure 4-5. Field Voltage and Current Measurement 4-8 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Field Current Feedback The field current is measured across a dc shunt at the SCR bridge. This generates a nominal 100 mV signal, which is input to a differential amplifier. The output voltage from the amplifier ranges from –5 V to +5 V. A VCO produces a linear proportional frequency of 0 to 2 MHz with an accuracy of 1% of full scale reading. These pulses drive the LED in the optical isolator coupled to the fiber-optic cable. Field Voltage Feedback The bridge voltage is measured across the negative terminal of the bridge and the positive terminal of the current shunt. After scaling the voltage with the jumpered resistors, the signals are input into a differential amplifier which controls the voltagecontrolled oscillator (VCO). The VCO produces a linear proportional frequency of 0 to 2 MHz with an accuracy of 1% of full-scale reading. The pulses drive the LED in the optical isolator coupled to the fiber-optic cable. EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-9 Auxiliary Cabinet Control Cabinet EDCF-1 EISB M1 Generator Field Voltage VFOF CFOF PPT Scaling P2 2 2 WH + - 1 BK 2 1 PSM1 P1 VCO - BK P24VDC Current Shunt (mv) Dc Shunt 1 + Volts Current E1 VCO Duplex FiberOptic Link To Bridge 2 41A + 1 Generator Field + BK - 2 WH Auxiliary Cabinet HS + De-Excit. FDI-1 SCR1 SCR3 SCR2 53B (W) Field L1 L2 L3 53B (Y) Flash TB1-1 Shaft TB1-2 Voltage SCR4 SCR5 SCR6 41B J1 J4 J2 J3 J5 J6 Control Cabinet J2/3M EXTB K41_M1 P125 K41_C K41_C To Bridge 2 1 J6 K41_M1 1 9 FILT1 K41_M2 K41_M2 Generator Field - 41B 41A 3 3 4 4 2 N125 Control Rack P70V 2 J505 EMIO M1 J505 3 J508 J508 EMIO M2 J515 J515 Feedback 70V Return EMIO C Figure 4-6. DC Field Circuit Contactor and Control Board 4-10 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide De-Excitation During shutdown of the generator, the stored energy of the generator field inductance must be dissipated. In the EX2100 exciter, this is the function of the EDEX de-excitation module and field discharge resistor or inductor (when supplied). Standard de-excitation is provided by a freewheeling diode. For higher performance applications, the de-excitation module consists of a thyristor (53 mm or 77 mm cell size) mounted in a large heatsink assembly with attached snubber network. The EDEX board contains Hall effect conduction sensors. The sensors are mounted in the air gap of a circular steel core attached to the board. They sense the magnetic field produced by the field discharge current flowing through the thyristor. Two independent sensor circuits are used. The EDEX fires the SCR when either of two control inputs is true or when the anode to cathode voltage of the SCR exceeds a certain value. The two firing control circuits on the board are powered from separate power supplies and use separate conduction sensors making them mutually independent. The actual control logic inputs used are dependent on the application. When the exciter shuts down, a P24 V firing control signal is sent to both de-excitation module firing control circuits. Both firing control circuits send gate pulses to fire the deexcitation SCR. At this point, the main field polarity reversal has occurred making the SCR anode positive with respect to the cathode. Therefore the SCR conducts and dissipates the stored energy of the generator field through the field discharge device. Feedback from either conduction sensor verifies that the discharge circuit has operated successfully. If both independent firing control circuits fail to fire, the SCR is fired by the anode firing circuit when the anode to cathode voltage has exceeded the selected level. For large exciters, it is possible to connect multiple de-excitation modules together with one EDEX board configured to be the Master and the other boards configured to be Slaves. In this case, a firing control signal sent to the Master is relayed to the Slave modules, firing all modules simultaneously. EXTB controls the main breaker or contactor in the field circuit. When this opens, the auxiliary contacts cause an immediate de-excitation commanded by EDEX. Deexcitation controlled by EXTB in both the contactor and breaker mode is shown in Figures 4-7, and 4-8. Location of the 41A dc contactor in the field circuit is shown in Figure 4-6. Contactor 41B is optional. Both contactors are located in the Power Conversion Cabinet, and are driven from the 41 Close pilot on the EXTB board. Several auxiliary contacts are used to provide status feedback to the control, and firing commands to the de-excitation board, EDEX. An alternative to an 41A and 41B contactor is to use a breaker in the excitation ac supply or dc field circuit. Normally, the breaker would be a dc field breaker that ccould break the output while inserting a discharge resistor with the normally open contact. But, an ac break with the SCR based de-excitation module could also be applied. The breaker has two coils, 41 Close and 41 Trip, and auxiliary contacts for de-excitation. Figure 4-8 shows how the breaker interfaces with the EXTB control board and EDEX. EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-11 Control Cabinet Auxiliary Cabinet De-Excitation Generator Field + HS- HS+ DEPL Generator Field - Conduction Sense Circuit Converter Cabinet EXTB G1 - Contactor Mode (Simplex version is G2) J505 FDI 2 J515 EDEX M1 De-Excit. Status M2 De-Excit. Status J508 1 J8 J8 2 2 5 5 M1 Status Status J6 Feedback 3 P24V M2 Firing Command 1 1 P24V To C 4 3 2 4 4 Ct Bkr M1 Firing N24 Command To M2 3 M2 Status P70V 70V Ret Self Firing To M1 3 3 7 4 4 5 6 6 Ct Bkr 8 N24 41 Trip Relays not present on G1 and G2 boards 7 7 8 8 1 1 2 2 6 M1 M2 P24 COM N24 1 P24 1 41 Close 2 COM 2 3 To EPBP J17M1 N24 P125 3 To EPBP J17M2 M2 C C M1 1 Bkr. Ct. A B 9 41A N125 KDEP A B 41B N125 P70VM1 P125 N125 2 1 J9 P70VM2 P70Vdc J12M2 J12M1 Figure 4-7. DC Contactor Control and Wiring to De-Excitation Board 4-12 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Auxiliary Cabinet Control Cabinet De-Excitation Generator Field + HS- HS+ DEPL 2 Conduction Sense Circuit M1 DeExc Status M2 DeExc Status Generator Field - EXTB G3 - Breaker Mode (Simplex version is G4) J505 To M1 FDI J508 1 2 To M2 J515 EDEX 2 J8 M1 2 Status 5 5 J8 M2 Status Self Firing P24V M2 Firing Command 1 Status J6 Feedback 3 4 3 4 4 Ct 7 5 Bkr Ct 8 6 N24V M1 M2 41 Trip M2 C 1 P24 M1 M2 1 41 Close M2 C COM 2 COM 2 N24 3 N24 To EPBP J17M1 6 C M1 P125 P24 3 CTB 2 1 3 6 To C 70V Ret P70V Bkr M1 Firing N24V P24V Command Customer Breaker 1 A A C M1 B Bkr Ct P125 B 9 N125 To EPBP J17M2 41 Breaker Close Trip KDEP N125 P70VM1 N125 P125 P70VM2 P70Vdc NC 1 2 3 J9 J12M2 J12M1 Figure 4-8. Ac or Dc Breaker Control and Wiring to De-Excitation Board EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-13 Crowbar The optional crowbar subsystem limits high negative voltages that can be induced into the PCM during a pole slip (loss of synchronization) event. Like the deexcitation module, the crowbar will self-fire based on selective field voltage limits. It includes a discharge resistor, which may be shared with the de-excitation function when the two are supplied together. This is typically only provided on generators with salient poles (hydro applications). Field Ground Detector The EGDM is an active system that applies a voltage to the field circuit. The generator field is an ungrounded system. The field ground detector (EGDM) detects field leakage resistance between any point in the field circuit of the generator and ground. The active detection system shown in Figure 4-9 applies a low frequency square wave voltage with respect to ground, and monitors for current flow through a high impedance ground resistor. The square wave is ±50 V dc at 0.2 Hz frequency. If PRV resistors are present, grounds anywhere in the system can be detected even while the exciter is not being fired, from the PPT secondary to any point in the generator field. The ground detector feedback voltage is sent over a fiber-optic link to the DSPX where it is monitored and alarmed. The DSPX controls the oscillator voltage over an adjacent fiber-optic link. In the case of redundant control, if the M1 controller fails, the oscillator in the M2 channel takes over, as commanded by controller C. One or three EGDMs are mounted next to the power supplies in the power backplane. 4-14 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Control Cabinet Auxiliary Cabinet Generator Field - Generator Field + From Flashing 53B Power Backplane EPBP Ground Detector Attenuator Module EXAM Control Backplane EBKP J2 Ground Detector Voltage EISB - M1 EGDM - M1 Optical Receiver VCO Oscillator Optical control Transmitter Oscillator 1 M2 M2 Optical Receiver VCO C Optical Receiver VCO Control +/-65 Vdc +5V +/-15V To DSPX Counters Oscillator Optical control Transmitter Oscillator 2 C To DSPX Counters Optical Transmitter To DSPX Counters Master Select Power Supply P24 V Figure 4-9. Field Ground Detector EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-15 Field Flashing The station battery is used to initiate the field current. An auxiliary ac source can also be used. Field flashing relays 53A and 53B are controlled from drivers on the EMIO board, through pilot relays on EXTB. In redundant control, the three driver signals actuate pilot relays on EXTB that are contact voted to output a single voltage. These outputs actuate the 53A and 53B relays in the Auxiliary Cabinet. The 53A and 53B contacts put dc voltage from the station battery across the generator field, as shown in Figure 4-10. The field flashing module supplies approximately 15 to 20% of AFNL to the generator field during the startup sequence. For ac field flashing, the ac voltage is rectified by a diode bridge and filtered. The startup sequences and logic are the same. Dc Field Flashing Settings Field flashing panels are used to supply a wide range of flashing currents. This happens if the flashing control fails, leaving the flashing current on continuously. The flashing current magnitude required for a generator is set by configuring a maximum and minimum allowable value in the control module. The current values are preset in the factory based on information supplied. These values define the envelope in which the hysteretic flashing control holds the field current during the flashing sequence. Flashing Control Sequence Flashing current flow is monitored by the control through the field shunt. A start request is issued by the operator. The optional field contactor(s) closes, followed by contactor 53B, then 53A. When the field current reaches the maximum allowable field flash value (typically 15 - 20% of AFNL), contactor 53A opens and the field current decays through the freewheeling diodes. If the control has not taken over before the current decays to the minimum field flash current setting, typically 10% AFNL, the sequence is repeated. If the current magnitude exceeds approximately 25% AFNL, or the control has not taken over after a fixed time delay, the startup is stopped and a diagnostic alarm is issued. 4-16 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide From Shunt1 + Generator Field - Station Battery 125 Vdc Auxiliary Panel Flashing 1 PTB-1 2 - + Shaft Voltage Suppresser w v 53B 53A 53B x x Y Y 53B J1 Aux 1 EXAM 1 TB1 J1 3 2 1 7 8 FBK1 FU1 2 4 2 3 3 5 3 FU2 1 2 6 4 EXTB 2 53B B A J7 4 4 M1 M2 10 10 M2 C 6 6 SUP SUP 53A A 9 9 2 2 5 5 1 53A Aux 2 C 53B P70Vdc J7 1 B M1 53B M2 53B Current Limit Circuit J5M1 M1-EMIO (J5) J5M2 M2-EMIO C M1 (J5) K53B relay contacts M1 M2 J5C C-EMIO (J5) M2 C C M1 K53A relay contacts 3 4 12 12 3 3 P70Vdc M1 53A M2 53A C 53A P70VDC P70VM2 P70VM1 Current Limit Circuit Figure 4-10. Field Flashing Control from EMIO and EXTB EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-17 Shaft Voltage Suppressor Excitation systems, which produce a dc voltage from an ac supply through a solid state rectification process, cause ripple and spike voltages at the exciter output. Due to their rapid rise and decay times these voltages are capacitively coupled from the field winding to the rotor body. This creates a voltage on the shaft relative to ground that, if not effectively controlled, can damage both journals and bearings. The shaft voltage suppressor is a filter that conducts the high frequency components of the induced voltages to ground and limits shaft voltage caused by thyristor commutation to less than 7 V zero to peak. For the connections to the field, refer to Figure 4-11. Generator Field - Generator Field + Shaft Voltage Suppressor C1 TB1-1 R1 C2 R5 R6 TB1-2 R2 R3 R4 TB1-3 Field Flashing J1-1 J1-2 7 8 53B AUX Thyrite TH1 TH2 Crowbar 1 CBRO 2 HSA Heatsink JCY JCX HSC DEPL EPL1 EPL2 Figure 4-11 Shaft Voltage Suppressor, Thyrite, and Crowbar 4-18 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Data Highway Connections The Data Highway integrates several different single control systems. The EX2100 exciter communicates over the same data highway as the Mark VI turbine control and the HMI. A typical exciter connection to the redundant Unit Data Highway (UDH) network is shown in Figure 4-12. This shows redundant control with two ACLAs. The UDH is implemented using commercially available fast Ethernet switches. 10Base-T cabling is used for short distances between the controller and the T-switch, and any local HMI. The 10BaseT ports in the ACLA and the T-switch are for RJ-45 connectors. The maximum distance for local traffic at 10 Mbps using unshielded twisted pair cable is 100 m. 100Base-FX fiber optics can be used for longer distance communication between the local controllers and the central control room. The 100BaseFX ports in the T-switch and the Ethernet switch are for SC type fiber-optic connectors. The maximum distance at 100 Mbps using 100BaseFX fiber-optic cables is 2 km. Redundancy can be obtained by using two T-switches with an interconnecting cable. Central Control Room Fast Ethernet Switch B Fast Ethernet Switch A From other Units From other Units T-Switch A 100Base-FX connections T-Switch B To local HMI Viewer, 10Base-T 10Base-T connections Local Control Area From other Controllers gGE Industrial Systems From other Controllers Exciter Control Cabinet gGE S T A T U S S T A T U S 2 ENET ENET Ethernet Port, RJ-45 COM 1 2 1 COM ACLA H1A Industrial Systems ACLA H1A Figure 4-12. Unit Data Highway Connections EX2100 User’s Guide GEH-6632 Chapter 4 Terminal Board I/O and Equipment Connections • 4-19 Control System Toolbox Connection The toolbox connector on the exciter backplane supports an RS-232C cable, which connects an external computer to the DSPX board. This connection is for maintenance purposes. There are three 9-pin connectors located at J303B, J310B, and J313B to support communication with controllers M1, M2, and C. (Refer to Figure 4-13). The UDH can also provide a toolbox interface using the Ethernet port on the ACLA. This is a 10BaseT port and uses an RJ-45 connector for unshielded twisted pair cable. UDH Ethernet Data Highway to Toolbox and HMI 2 1 2 1 ACLA DSPX EISB Toolbox RS-232C Computer Cable Connections EMIO ESEL ESEL EMIO J304 Key Pad M1 J404 Tool M1 Test Rings M1 J504 E A C F J602 M1 Power J305 J306 J307 J308 E P C T E G P A 1 E G P A 2 E P C T J405 J406 J407 J408 E C T B E G P A 3 E G P A 4 E C T B J505 J506 J507 J508 E X T B E G P A 5 E G P A 6 E X T B DSPX ACLA DSPX EISB EISB J309 EMIO J314 Key Pad M2 E P C T Key Pad C J409 J414 Tool M2 Tool C Test Rings M2 Test Rings C J514 E A C F E A C F J610 J612 C Powr J415 E C T B J509 M2 Power J315 J515 E X T B IS200EBKP Figure 4-13. Toolbox Connections 4-20 • Chapter 4 Terminal Board I/O and Equipment Connections GEH-6632 EX2100 User’s Guide Chapter 5 Diagnostic Interface-Keypad Introduction This chapter provides operating guidelines for the Diagnostic Interface, more commonly called the keypad. The keypad is a door-mounted, local control unit that enables you to: • Monitor frequency, current, power, and voltage • Start and stop the exciter • Set and adjust configuration parameters • Examine and reset fault conditions This chapter is organized as follows: Section Page Using the Pushbuttons.............................................................................................. 5-2 Reading the Display................................................................................................. 5-5 Changing Display Units.................................................................................... 5-7 Adjusting Display Contrast............................................................................... 5-7 Status Screen............................................................................................................ 5-8 Reading the Meters ........................................................................................... 5-8 Alternate Status Screen (Display I/O)...................................................................... 5-8 Using the Menus ...................................................................................................... 5-9 Viewing and Resetting Faults .................................................................................. 5-9 Editing Parameters ................................................................................................. 5-10 Parameter Backup........................................................................................... 5-11 Firmware and Hardware Information..................................................................... 5-13 Protecting the Keypad............................................................................................ 5-14 Modifying the Protections .............................................................................. 5-14 EX2100 User’s Guide GEH-6632 Chapter 5 Diagnostic Interface-Keypad • 5-1 Using the Pushbuttons The keypad includes membrane-type pushbuttons to access exciter values and to control the exciter. Tables 5-1 and 5-2 define the pushbutton functions for menu navigation and exciter control (see Figure 5-1). g EX2100 Excitation Control Exciter Health & State Icons FVR Feedback 0.0 Volts FldCurrAmps 0.00 Amps Vmag Imag 0.00 0.00 Freq_Hz Balance Meter 60.00 -30% 0% 100% 150% -30% 0% 100% 150% Watts 0.00 Vars 0.00 0.00 Navigation Exciter Control Status Reset Faults Auto Menu Command Man Menu Run (Green) Voltage Level Escape On Stop (Red) Off Enter Display: Pushbuttons: Status screens provide analog and digital representation of exciter functions and values. Organized into functional groups: Menu screens provide text-based access to parameters, wizards, and faults. Navigation buttons for using the menu Exciter Control buttons Run and Stop buttons Figure 5-1. Diagnostic Interface - Keypad 5-2 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide Table 5-1. Navigation Pushbuttons Button Function Status Displays the default Status Screen, which shows eight parameters as numbers or bargraphs. A set of Health icons (displayed at all times; see Exciter Health and State Icons) provides additional exciter status information. Menu If pressed while displaying a Menu screen (see Menu Selections), displays the Main Menu.If pressed while displaying a Status screen, displays the last Menu screen. If held down, the up and down arrow keys adjust screen contrast Menu Navigation: Used to highlight (reverse image) an item in a menu of options. Adjust Contrast, if menu key is held down. Entry of Numeric Parameter: Used to index through numbers (0-9, ., -) when editing a parameter. Entry of Option Parameter: Used to index through 1 – n choices. (See Parameter Configuration.) Menu Navigation: Right Arrow button displays the next selected level down in a menu tree. Left Arrow button displays next level up in menu tree. Entry of Numeric Parameter: Used to select a digit when editing a parameter. Entry of Option Parameter or Command Execution: Not functional. Escape Enter Menu Navigation: Displays the next level up in menu tree. Entry of Parameter: Displays the parameter list. Menu Navigation: Displays the next level down in menu tree. Entry of Parameter: Accepts editing of parameter. EX2100 User’s Guide GEH-6632 Chapter 5 Diagnostic Interface-Keypad • 5-3 Table 5-2. Exciter Control Pushbuttons Button Reset Faults Command Menu Function Resets faults. Quick access to a list of commonly used commands Auto Selects Auto mode (AC regulator or AVR) Man Selects Manual mode (DC regulator or FVR) Increase voltage, VARS, PF Decrease voltage, VARS, PF Run Stop 5-4 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide Reading the Display The keypad displays information as both text and animated graphics. There are two types of content screens, selected by pressing the corresponding Navigation button: Status and Menu. The Status Screen (Figure 5-2) is the default screen that displays after exciter startup, following an initialization screen. It uses animated meters with associated text to present exciter performance data. An alternate Status Screen can also be accessed (see Status Screen). Text Identifying Exciter Variable Heartbeat Animated Meters Fault State FVR Feedback 0.0 Volts FldCurrAmps 0.00 Amps Vmag Imag 0.00 0.00 Freq_Hz Balance Meter 60.00 0.00 -30% 0% 100% 150% Limiter -30% 0% 100% 150% Auto Mode Watts Running 0.00 Vars 0.00 Online Figure 5-2. Status Screen Example The Menu Screen (see Figure 5-3) lists and provides access to menu-based functions for adjusting parameters, running wizards, and viewing faults (see Menu Selections). Main Menu Fault List Alarms Alarm String Application data Diagnostic and utility functions General setup I/O interface Figure 5-3. Menu Screen Example The Exciter Health and State Icons continually show on the right hand side of all display screens. They indicate if the exciter is functioning correctly and show its running state. These icons are displayed in five functional groups, as shown below. You can change the display units and adjust the display contrast, if needed. EX2100 User’s Guide GEH-6632 Chapter 5 Diagnostic Interface-Keypad • 5-5 Table 5-3. Exciter Health and State Icons Group Icon Heartbeat Control Blank Fault State blinking o Indication Description Communications OK Animated line (its center raises and lowers) shows that there is communication between the keypad and the exciter. Communications not established Animated metronome icon shows that the keypad is attempting to establish communication with the exciter, but cannot. Auto mode Regulates terminal voltage. Manual mode Regulates field voltage. Test Mode The exciter is performing a diagnostic test. Exciter OK When no icon displays, the exciter is operating correctly. Abnormal Displayed when there are over-ridden parameters. Alarm state Displayed when an alarm condition occurs. Trip fault Displayed when a fault state occurs. Stopped Exciter is stopped. Running Exciter is running. Limiting Field voltage regulator output is greater than field current regulator or V/Hz or UEL limits are active. Offline Exciter is offline. Online Exciter is online. Status 5-6 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide Changing Display Units Ø To change the type of measurement units displayed 1. From the Main Menu, select General Setup. 2. Select Display Units. 3. Select the display units parameter to edit it (see below). 4. Highlight, then select the preferred display units. Press ENTER to accept, ESC to leave Display units New Value = Metric (SI) Present Value = Metric (SI) Adjusting Display Contrast Shortcut – Press and hold the Menu key. Press the Up and Down arrows to adjust the display contrast. Ø To adjust the display contrast 1. From the Main Menu, select General Setup. 2. Then select: a. Keypad b. Keypad Functions c. Adjust Screen Contrast This displays the following screen. - CONTRAST ADJUSTMENT HOLD UP ARROW TO INCREASE HOLD DOWN ARROW TO DECREASE Press ESCAPE to Continue 3. EX2100 User’s Guide GEH-6632 Press the Escape button to save the contrast value and return to the previous menu. Chapter 5 Diagnostic Interface-Keypad • 5-7 Status Screen The Status screen displays up to eight variables (parameters). The first two parameters are displayed both in text and animated meters. Table 5-4 defines the characteristics of the bar graphs for these parameters. Reading the Meters A variable shown as a bar graph is over range when it is either greater than + 100% or less than –100%. The over range mark is shown with a vertical bar through the bar graph at the +100% and the –100% marks. Not Over Range +100% -100% Over Range Table 5-4. Animated Meter Characteristics (Default) for Status Screen Bar Graph Variable Numeric Display DC bus voltage Magnitude of dc bus voltage (FVR feedback) Percentage of dc per unit volts (VDC_PU) AC line current Magnitude of ac line current (I_Mag_Fil) Percentage of source top-rated current (I_PU) Units in Bar Graph Alternate Status Screen (Display I/O) The keypad has an alternate Status screen that displays the status of the general purpose inputs and outputs. To toggle between the Meter Status Screen and the I/O Status Screen, press any of the Arrow buttons. The circle under each heading indicates the status of the corresponding I/O point, as follows: • l = True • ¡ = False Display I/O Status 1 2 3 4 5 6 GP Inputs GP Outputs 5-8 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide Using the Menus The keypad’s Main Menu leads to other menu screens, where data can be reviewed and modified. The Main Menu can be accessed from any screen, as follows: • If already in a Menu screen, press the Menu button. • If in a Status screen, press the Menu button once or twice. Main Menu Fault List Alarms Alarm String Application data Diagnostic and utility General setup i I/O interface Note The Main Menu selections may vary from product to product. Use the Navigation buttons to move through the menus, select items, and adjust values • Press the Up or Down Arrow buttons to move through and highlight menu items. • Press the Enter button to select a highlighted item • To return to a previous menu screen, press the Escape button, Left Arrow button, or follow on-screen instructions. • When a menu has more than one screen: – Move to the next screen by highlighting the last item on the displayed screen, then press the Down Arrow button once more. – If the last menu item is reached, then pressing the Down Arrow button will wrap back to the first item on that menu. Viewing and Resetting Faults When the display indicates either a Trip or an Alarm fault (refer to Reading the Display), you can view information and reset (clear) current faults, as follows: 1. Faults are displayed in order of occurrence with the most recent fault at the top. From the Main Menu, select Fault List, then select Display Active Faults. The following screen displays. ACTIVE FAULT DISPLAY 86 Trip DC Over-current Trip 115 Trip Bridge 1 Fan 1 BAD 58 Brief Low AC V 95 Field temp alarm --- RESET FAULTS NOW --- Refer to GEH-6633 Troubleshooting, Preventive and Online Maintenance, for a list of faults. EX2100 User’s Guide GEH-6632 Chapter 5 Diagnostic Interface-Keypad • 5-9 2. To view detail on a particular fault, select that fault (listed on the Active Fault Display screen). The following screen displays. SELECTED FAULT - PRESS Low AC V, B 006:40:11.008 Low AC input volts detected on the field exciter. 3. Reset the faults either of two ways: - Select Reset Faults Now in the Fault Display screen. - Press the Reset Faults button. Ø This display list may be multiple screens long. To view the exciter’s Fault History (a list of previously cleared faults and fault resets) • From the Main Menu, select Fault List, then select Display Fault History. FAULT HISTORY DISPLAY 0 Cleared Fault reset 86 Trip DC Over-current trip. 115 Trip Bridge 1 Fan 1 BAD 58 Brief Low AC V 95 Field temp alarm --- RESET FAULTS NOW --- Editing Parameters There are two types of parameters that can be changed using the keypad: • Option parameters lists items (options) for you to select. For example, True/False is an option parameter. • Numeric parameters lists valid digits that you select to create a number. Ø To edit a parameter 1. From an exciter Parameters screen, select the parameter that is to be changed. Parameters GPT_Vrms VHiTripLev AFFL TripVHiTrip VFFL 100.0 = = = = = <No Value> 1.2 100 Trip enabled 100 This displays either an Option or Numeric parameter screen (see both below) with the New Value line highlighted. 5-10 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide 2. For an Option parameter: a. Use the Up or Down Arrow buttons to select a new parameter value. b. Press the Enter button to accept the change or Escape to exit and keep the present value. Press ENTER to accept, ESC to leave TripVHiTrip New Value = Trip disabled Present Value = Trip enabled 3. For a Numeric parameter: a. Use the Left or Right Arrow buttons to highlight the digit to be changed. If you continue pressing the Left Arrow button after reaching the left-most digit of the edit field, the field fills with blanks. Pressing Enter when the entire number is blanked out saves a <No Value>. b. Use the Up and Down Arrow buttons to index through the valid digits (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, e, ., -). The e in the digit selection represents the start of the exponent in scientific notation. If the e is used, all digits to the right of the e make up the number’s exponent. Press ENTER to accept, ESC to leave VHiTripLev New Value Present Value Low Limit High Limit 4. = = = = 1.3 1.2 0.0000000 3.4028239e38 When all of the digits have been changed, press Enter to accept the new value or press Escape to exit and keep the present value. Parameter Backup It is good practice to keep a backup copy of the exciter’s working parameter configuration. You can then restore this file, if needed, or compare it with a reconfigured file to determine differences. Each new backup overwrites the previous backup copy, which cannot be restored. Ø To save active parameters 1. From the Main Menu, select Parameter Backup Functions then select Save Parameters to Backup. Save Parameters to Backup Save current parameter values. Press ENTER to continue. EX2100 User’s Guide GEH-6632 ESC cancels. Chapter 5 Diagnostic Interface-Keypad • 5-11 2. Press Enter to make a backup copy of the parameters or Escape to cancel. Ø To restore a parameter from backup 1. Stop the exciter. (This function cannot be executed with the exciter running.) 2. From the Main Menu, select Parameter Backup Functions then select Restore Parameters from Backup. Press to restore Parameters from Backup -- WARNING -The active parameter values will be replaced, and can not be recovered. Press ENTER to continue. 3. ESC cancels. Press Enter to restore the backup parameters or Escape to cancel. Restoring parameters from a backup file overwrites the currently active parameter values, which cannot then be restored. Ø To compare the active parameter set to the backup parameter set 1. From the Main Menu, select Parameter Backup Functions then select Compare Current Parameters to Backup. BACKUP DIFFERENCES VHiTripLev = Backup value = AFFL = Backup value = VFFL = Backup value = <More ↑ > 1.3 1.2 112.0 100.0 110.0 100.0 <More ↓> 2. Use the Up and Down Arrow buttons to scroll through the list of backup differences. 3. Press Escape to return to the previous menu. 5-12 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide Firmware and Hardware Information Ø To view the firmware versions for the DSPX board and the keypad From the Main Menu select: 1. General Setup 2. Firmware Version & Hardware Info 3. Display Firmware Version The following screen displays: GE Generator Control EX2100 DSPX Firmware Version: V02.06.00B DSPX Boot Monitor Version: V02.02.00C DDI Firmware Version: V02.00.00B Press ESC to exit Ø To view exciter hardware information From the Main Menu select: 1. General Setup 2. Firmware Version & Hardware Info 3. Display Hardware Information The following screen displays: GE Generator Control Hardware Information: IS200ESELH1APR 5473716 IS215ACLAH1AL 8790070 IS200DSPXH1CAA 7611193 IS200EMIOH1APR 7360814 IS200EISBH1APR 5673766 <More ESC to exit EX2100 User’s Guide GEH-6632 ↓> Chapter 5 Diagnostic Interface-Keypad • 5-13 Protecting the Keypad To protect the exciter from unauthorized operation or reconfiguration, the keypad includes two security controls, Password and Privilege Level. The Password is a 5-digit number that protects the Password and Privilege Level from being changed by unauthorized personnel. The default Password is 00000. Privilege Level specifies which operational and configuration functions are disabled in the keypad. There are three levels: • Read Only disables both the Exciter Control and the Configuration functions. An operator can view but not edit parameters. • Operate & Read Only enables the Exciter Control function, but disables Configuration functions. An operator can view, but not edit parameters. • Configure & Operate enables both the Exciter Control and the Configuration functions. This is the default setting. If you try to execute a function that is disabled in the active Privilege Level, the keypad displays the following error message. Incorrect password! Press Any Key to Continue Modifying the Protections Ø To modify the Password and Privilege Levels 1. From the Main Menu, select: a. General Setup b. Keypad c. Keypad Security The following screen displays: Press ENTER to accept, ESC to leave Enter Password: 5-14 • Chapter 5 Diagnostic Interface-Keypad 00000 GEH-6632 EX2100 User’s Guide 2. Enter the password as follows: a. Use the Up and Down Arrow buttons to index through the valid digits (0 through 9). b. Use the Right and Left Arrow buttons to move the cursor to the digit to edit. - Press Enter to accept the Password. - If the password that was entered matches the saved Password value, you can then modify the Privilege Level or Password. Keypad Security Keypad privilege Keypad password =Configure & = If it does not match, the keypad displays an error message. Incorrect password! Press Any Key to Continue 3. Use the Up and Down Arrow buttons to select either the Privilege Level or Password. 4. Press Enter to edit the parameter. (See Editing Parameters.) Note When you modify the keypad password, be sure to select Save Parameters To Backup. Otherwise, the password stored in the active parameter will not match the backup parameter set. That causes the Compare Current Parameters to Backup to identify the Keypad Password parameter as different. EX2100 User’s Guide GEH-6632 Chapter 5 Diagnostic Interface-Keypad • 5-15 Notes 5-16 • Chapter 5 Diagnostic Interface-Keypad GEH-6632 EX2100 User’s Guide Appendix A Warranty and Renewal Parts Introduction When ordering a replacement part for a GE exciter, the customer needs to know: • How to accurately identify the part • If the part is under warranty • How to place the order This information helps ensure that GE can process the order accurately and as soon as possible. To minimize system downtime if repair is needed, GE recommends that the customer keep a set of spare parts on hand. The Renewal Parts Quotation lists recommended spares. Appendix A of this manual provides information to help the user identify and obtain replacement parts. It is organized as follows: Section Page Identifying the Part ................................................................................................. A-2 Renewal Parts List ........................................................................................... A-2 Part Number Structure ..................................................................................... A-2 Warranty Terms ...................................................................................................... A-4 How to Order Parts ................................................................................................. A-5 Data Nameplate ............................................................................................... A-5 ML Number ..................................................................................................... A-5 EX2100 User’s Guide GEH-6632 Appendix A Warranty and Renewal Parts • A-1 Identifying the Part An exciter component, or part, is identified by its assigned part number and description. The part number is normally found on a nameplate on the component. The description is included in the system renewal parts list. Renewal Parts List The Renewal Parts List is a separate document that lists the parts of a complete system. This list applies specifically to the equipment furnished on a customer’s particular application (requisition) at the time of shipment. It includes: • Part numbers and descriptions • Quantity used • Recommended spares to keep onhand • Normal delivery cycle for obtaining each part GE provides the Renewal Parts List with the exciter’s custom instructions. If this document is missing, contact the nearest GE sales office or service representative to obtain a replacement copy. You need to provide the following information (see Figure A-4) to correctly identify the system: • Requisition number • Model number Part Number Structure A GE part number is structured so that different portions of the number identify the type of equipment and location of manufacture. A part falls into one of four categories: • Order-specific assemblies – Major assemblies or items that make up a specific exciter, constructed from common assemblies • Common assemblies – Subassemblies used in many GE exciter products, not just a specific exciter • Components – Individual parts that make up assemblies • Printed wiring boards These categories and the makeup of their part numbers are defined under Order Specific Assemblies. A-2 • Appendix A Warranty and Renewal Parts GEH-6632 EX2100 User’s Guide Order Specific Assemblies These parts make up the particular exciter. Other items obtained specifically for the order may also use a similar part number structure, which provides information about the equipment. 3V AAA 123 XX### Unit & sequence number of Sequence/projec Order product line Unique to req'n Identifies manufacturer as GE Systems, Salem, Sample Part Number for Order-Specific Assembly Common Assemblies Common assemblies are subassemblies used as components of order-specific assemblies. Common assemblies are not designed for a particular exciter, but provide a function used in other GE products. For example, 36C774524AAG48 is the part number for a cable. Components Components are the basic parts that make up assemblies. They represent the lowest discrete level of a system. Component part numbers consist of a combination of alphanumeric characters that define the class and specific item. A sample number is shown below. 104X 109 1ADO38 Item or rating (500 V, 3.2 A FNQ) Component type (fuse) Component Sample Part Number for Component EX2100 User’s Guide GEH-6632 Appendix A Warranty and Renewal Parts • A-3 Printed Wiring Boards A printed wiring board is identified by an alphanumeric part (catalog) number stamped near its edge. The structure of a board’s part number is described below. Note All digits are important when ordering or replacing any board. The factory may substitute later versions of boards based on availability and design enhancements. However, GE Industrial Systems ensures compatibility of replacement boards. IS 200 DSPX G# A A A Artwork revision1 Functional revision1 Functional revision2 Group (variation, G or H) Functional acronym Assembly level3 Manufacturer (DS & IS for GE in Salem, VA) 1Backward compatible backward compatible 3200 indicates a base-level board; 215 indicates a higher-level assembly or added components (such as PROM) 2Not Sample Board Part Number Warranty Terms The GE Terms and Conditions brochure details product warranty information, including warranty period and parts and service coverage. The brochure is included with customer documentation. It may be obtained separately from the nearest GE Sales Office or authorized GE Sales Representative. Note Standard warranty is 18 months from shipment or 12 months from when power is first applied, whichever comes first. A-4 • Appendix A Warranty and Renewal Parts GEH-6632 EX2100 User’s Guide How to Order Parts Parts still under warranty may be obtained directly from the factory: GE Industrial Systems Product Service Engineering 1501 Roanoke Blvd. Salem, VA 24153-6492 USA Phone: + 1 800 533 5885 (United States, Canada, Mexico) + 1 540 378 3280 (International) Fax: + 1 540 387 8606 (All) (“+” indicates the international access code required when calling from outside of the USA.) Renewals (spares or those not under warranty) should be ordered by contacting the nearest GE Sales or Service Office. Be sure to include: • Complete part number, located in the renewal parts list • Part name • Exciter model, located in it's nameplate Data Nameplate The data nameplate is located on the back of the cabinet door. It provides information needed when ordering parts or contacting GE for assistance. ML Number Each GE lineup, cabinet (panel)/case, and core unit has a unique identifying catalog number, also called the part or material list (ML) number. This number is structured to provide information about that equipment. The catalog number links the equipment to its requisition, drawings, components, materials, specification item, and shipping documents. 3V AAA 123 XX### Unit & sequence number of components: CA## = Case assembly CD## = Core dc drive controller CI### = Core ac drive controller LU### = Lineup, multiple case assembly PN## = Panel assembly RL## = Requisition-level assembly Sequence/project Unique Order month/year/ to req'n product line Identifies manufacturer as GE Industrial Systems, Salem, VA Sample Exciter ML (Catalog) Number EX2100 User’s Guide GEH-6632 Appendix A Warranty and Renewal Parts • A-5 Notes A-6 • Appendix A Warranty and Renewal Parts GEH-6632 EX2100 User’s Guide Appendix B Ratings and Specifications The actual equipment rating is on your exciter nameplate. This appendix indicates the range of possible product offerings but not necessarily the capability of your exciter. EX2100 Specification Description Power Conversion Module (PCM) Single bridge rating 1,000 and 2,000 A dc at up to 1,000 V ac Parallel bridge rating 8,000 A dc at up to 1,500 V ac, with up to 6 bridges Forcing requirements 150% of design Amperes (EDA) for 30 s at 40 ºC Power Sources Power for the PCM – Voltage source Auxiliary bus Generator terminals Compound Source 600 or 1,000 V versions Power for the PCM – VA (power) 3,251 KVA (1,000 V version) Power for the PCM - Frequency 3-phase 50/60 Hz, ± 5% Power to the Cooling Fans (3) 10 A rms, 125 V ac single source Flashing power 125-250 V dc battery source, with up to 200 A for at least 10 s 380-480 V ac, 50/60 Hz single-phase auxiliary source Control power (redundant with 2 bridges, warm backup} For two ac sources, or one ac and one dc source Nominal 120 V ac ±15%, with 1 DACA, 10 A rms max. Battery source 125 V dc, range 80-140 V dc, 10.6 A dc max. Heat loss in single PCM cabinet EX2100 User’s Guide GEH-6632 10 KW for a 2000 A, 1,000 V ac PCM Appendix B Ratings and Specifications • B-1 Input/Output QTY Potential transformers (PTs) 2 3-phase standard, single-phase available 120 V ac nominal 1 VA nominal burden Current transformers (CTs, 1 or 5 A) 2 Any two phases, single phase is available 1 VA nominal burden 86G dedicated contact input 1 Open for trip 52G dedicated contact input 1 Closed for online Trip rated contact outputs 2 At 125 V dc the relay break characteristics are: Resistive load 0.5 A Inductive load 0.2 A General Purpose contact inputs 6 Customer contact, 70 V dc supplied by ECTB General Purpose Form C contact outputs 4 At 125 V dc the relay break characteristics are: Resistive load 0.5 A Inductive load 0.1 A ± 10 V differential amplifier input 1 Control Automatic ac Voltage Regulation Proportional + Integral, software implemented ± 0.25 % over full voltage range Manual dc Voltage regulator Proportional + Integral, software implemented ± 2.0 % over full voltage range Protection Features Under Excitation Limiter, (UEL) Over Excitation protection (76) Generator Field Ground detection (64F) Generator Overvoltage protection (24G) Loss of Excitation protection (40) V/Hz limit (24) and trip (24T) Bridge Over Temperature (26) Field Over Temperature (49) Phase Unbalance (22) PT Failure (60) Environmental Control & Protection Base controls cabinet Continuous operation in a 0 to 40 ºC ambient environment Base power bridge and auxiliary cabinet Continuous operation in a 0 to 40 ºC ambient environment, with 5 to 95% humidity, non-condensing Storage Temperature -40 ºC to +70 ºC Humidity 5 to 95% humidity, non-condensing Altitude Normal operation at 0 to 1000 m. Derate 6% per 1000 m above 1000 m Cooling Forced air cooling required for PCM cabinet Contaminants, withstand 10 PPB of these: Reactive Sulfur, Reactive Chlorine, Hydrogen Sulfide Sulfur Dioxide, Chlorine Dioxide, Sulfuric Acid Hydrochloric Acid, Hydrogen Chloride, Ammonia Vibration Seismic Universal Building Code (UBC) – Seismic Code section 2312 Zone 4 Shipping 72 hours at 0.3 G rms between 4 to 16 Hz Operating/Installed at Site 1.0 G Horizontal, 0.5 G vertical at 15 to 150 Hz 3 shocks of 15 G, 2 ms impulse for all three axes B-2 • Appendix B Ratings and Specifications GEH-6632 EX2100 User’s Guide Cabinet Dimensions & Weight Redundant control with dual PCM redundant converter in a three-cabinet lineup Width 141.74 in (3600 mm) Height 104.32 in (2650 mm) Depth 31.5 in (800 mm) Weight of Converter cabinet 3,600 lbs. Weight of Total Lineup (Converter, Control, and Auxiliary cabinets) 5,600 lbs. Cabinet type, control & auxiliary NEMA 1 (IEC IP 20), convection cooled Cabinet type, power conversion NEMA 1 (IEC IP 20), forced air cooled Power and Control Cable Access Entrances from the top and/or bottom Reliability MTBF - Mean Time Between Failures Simplex system 25,000 hrs MTBF - Mean Time Between Failures Redundant system 175,000 hrs MTTR - Mean Time to Repair Any subsystem 4 hrs Acoustic Generated Acoustic Noise (Preliminary) PCM cabinet approximately 75 dB Codes and Standards UL 508C Safety Standard Industrial Control Equipment CSA 22.2 No. 14 Industrial Control Equipment UL 796 Printed Wire Board Assemblies ANSI IPC Guidelines IEC 801-2:1991 Electrostatic Discharge Susceptibility ENV 50140:1993 Radiated RF Immunity EN 50082-2:1994 Generic Immunity Industrial Environment IEC 801-4 Electrical Fast Transient Susceptibility IEC 1000-4-5 Surge Immunity IEC 1000-4-6 Conducted RF Immunity ENV 55011:1991 ISM Equipment Emissions EN 61010-1 Safety of Electrical Equipment, Industrial Machines IEC 529 Intrusion Protection Codes/NEMA 1/IP 20 IEEE 421.1 Standard Definitions for Excitation Systems for Synchronous machines IEEE 421.2 Guide for Identification, Testing, and Evaluation of the Dynamic Performance of Excitation Control Systems IEEE 421.3 High-Potential Test Requirements for Excitation Systems IEEE 421.4 Guide for the preparation of Excitation Systems Specs IEEE 421.5 Recommended Practice for Excitation Systems for Power Stability Studies EN50178/LVD/EMC CE Compliance IEEE C57.12.01 General Requirements for Dry-Type Distribution & Power Transformers IEEE C57.110 Recommended Practice for Establishing Transformer Capability when supplying Non-Sinusoidal Load Currents IEEE C57.116 IEEE Guide for Transformers Directly Connected to Generators IEEE C37.90.1 Surge Withstand Capability (SWC) tests for Protective Relays and Relay Systems IEEE C57.18.10 Practices and Requirements for Semiconductor Power Rectifier Transformers EX2100 User’s Guide GEH-6632 Appendix B Ratings and Specifications • B-3 Notes B-4 • Appendix B Ratings and Specifications GEH-6632 EX2100 User’s Guide Glossary of Terms 6U Full height Versa Module Eurocard (VME) board application code Software that controls the machine or process, specific to the application. ASCII American Standard Code for Information Interchange. An 8-bit code used for data. auxiliary source A source of three-phase ac power for the exciter, but not from the generator being controlled. automatic voltage regulator (AVR) AVR is controller software that maintains the generator terminal voltage through the Field Voltage Regulator. baud A unit of data transmission. Baud rate is the number of bits per second transmitted. BIOS Basic input/output system. Performs the controller boot-up, which includes hardware self-tests and the file system loader. bit Binary Digit. The smallest unit of memory used to store only one piece of information with two states, such as One/Zero or On/Off. EX2100 User’s Guide GEH-6632 Glossary of Terms • i block Instruction blocks contain basic control functions, which are connected together during configuration to form the required machine or process control. Blocks can perform math computations, sequencing, or regulator (continuous) control. board Printed wiring board or card. bus Upper bar for power transfer, also an electrical path for transmitting and receiving data. bumpless No disruption to the exciter when transferring control. byte A group of binary digits (bits); a measure of data flow when bytes per second. CMOS Complementary metal-oxide semiconductor. COM port Serial controller communication ports (two). COM1 is reserved for diagnostic information and the Serial Loader. COM2 is used for I/O communication configure To select specific options, either by setting the location of hardware jumpers or loading software parameters into memory. crowbar The crowbar limits the high negative voltages that can be induced into the PCM during a pole slip (loss of synchronism) event. It includes a discharge resistor, and is self firing. CT Current Transformer, used to measure current in an ac power cable. DACA Ac to dc converter for power supply, produces 125 V dc. ii • Glossary of Terms GEH-6632 EX2100 User’s Guide DCS (Distributed Control System) Control system, usually applied to control of boilers and other process equipment. de-excitation The de-excitation circuit provides a conduction path through a discharge resistor to dissipate the field current after a unit trip. device A configurable component of a control system. DRAM Dynamic Random Access Memory, used in microprocessor-based equipment. EGD Ethernet Global Data, a control network and protocol for the controller. Devices share data through EGD exchanges (pages). EMI Electro-magnetic interference; this can affect an electronic control system. EPBP Backplane Exciter Power Backplane holds power supply modules, ground detect modules, and connectors for power distribution. EPDM Exciter Power Distribution Module distributes 125 V dc to the power supplies. Ethernet LAN with a 10/100 M baud collision avoidance/collision detection system used to link one or more computers together. Basis for TCP/IP and I/O services layers that conform to the IEEE 802.3 standard. EX2100 Exciter GE static exciter; regulates the generator field current to control the generator output voltage. fanned input A termination board input that is connected to all three redundant controllers. EX2100 User’s Guide GEH-6632 Glossary of Terms • iii fault code A message from the controller to the HMI indicating a system warning or failure. field flashing The supply of initial exciter current during startup, usually from station batteries. field ground detector The field ground detector is an active circuit that detects a ground in either the ac or dc sections of the exciter and field wiring. field voltage regulator (FVR) FVR is controller software that maintains the generator terminal voltage using inputs from the Automatic Voltage Regulator (AVR) and the field voltage feedback. firmware The set of executable software that is stored in memory chips that hold their content without electrical power, such as EEPROM or Flash. flash A non-volatile programmable memory device. FVR Field Voltage Regulator, software controlling the voltage across the field. gating Controlling the conduction of the power SCRs with an input pulse train (or a voltage). health A term that defines whether a signal is functioning as expected. heartbeat A signal emitted at regular intervals by software to demonstrate that it is still active. HMI Human Machine Interface, usually a PC running Windows NT and CIMPLICITY HMI software. iv • Glossary of Terms GEH-6632 EX2100 User’s Guide hot backup Two bridges are used but only one is connected to the field, the other (the backup) is connected to a small dummy load. If the active bridge fails it is disconnected from the field by relays, and the backup is connected. ICS Integrated Control System. ICS combines various power plant controls into a single system. IEEE Institute of Electrical and Electronic Engineers. A United States-based society that develops standards. I/O Input/output interfaces that allow the flow of data into and out of a device. I/O drivers Software that interfaces the controller with input/output devices, such as communication networks, sensors, and solenoid valves. IP address The address assigned to a device on an Ethernet communication network. line filter Filter networks across the three-phase input lines to the exciter to minimize the voltage spikes that result from the abrupt decay of current during SCR commutations. LCI Static Starter Electric power device that runs the generator as a motor to bring a gas turbine up to starting speed. logical A statement of a true sense, such as a Boolean. Mark VI turbine controller A control system hosted in one or more VME racks that performs turbine-specific speed control, logic, and sequencing. EX2100 User’s Guide GEH-6632 Glossary of Terms • v Modbus A serial communication protocol developed by Modicon for use between PLCs and other computers. multiple bridges Several power producing bridges operate in parallel to produce a high field current. These share the exciter current load to provide redundancy and increased reliability. NEMA National Electrical Manufacturers Association; a U.S. standards organization. non-volatile Memory specially designed to store information even when the power is off, for example Flash memory. OLR On-Line Repair, capability provided by redundant control elements. over-excitation limiter (OEL) OEL software limits the excitation current to prevent overfluxing the generator power conversion module (PCM) The PCM or Bridge consists of six three-phase rectifiers, with associated protection and control devices, to generate the dc field current. power current transformer (PCT) A PCT can be attached to the generator line to provide a portion of the three-phase power for the exciter, part of a compound source. power distribution module (EPDM) The PDM distributes 125 V dc to the power supplies for the controllers and I/O termination boards. power potential transformer (PPT) A PPT is attached to the generator terminals to provide three-phase power for the exciter; referred to as a potential source. power system stabilizer (PSS) PSS software produces a damping torque on the generator to reduce generator oscillations. vi • Glossary of Terms GEH-6632 EX2100 User’s Guide product code (runtime) Software stored in the controller’s Flash memory that converts application code (pcode) to executable code. PRV Peak Reverse Voltage is limited with pole slip resistors, wired across the SCRs. PT Potential Transformer, used for measuring voltage in a power cable. real-time Immediate response, referring to control systems that must respond instantly to changing conditions. reboot To restart the controller or toolbox. Redundant A system consisting of duplicated components (boards or modules), which can transfer functionality from a failed component to one of the duplicate components without loss of the entire system’s functionality. relay ladder diagram (RLD) A ladder diagram represents a relay circuit. Power is considered to flow from the left rail through contacts to the coil connected at the right. RFI Radio Frequency Interference; this is high frequency electromagnetic energy which can affect the control system. RTD Resistance Temperature Device, used for measuring temperature. runtime See product code. runtime errors Controller problems indicated on the front panel by coded flashing LEDS, and also in the Log View of the toolbox. EX2100 User’s Guide GEH-6632 Glossary of Terms • vii sampling rate The rate at which process signal samples are obtained, measured in samples/second. serial loader Connects the controller to the toolbox PC using the RS-232C COM ports. The Serial Loader initializes the controller flash file system and sets its TCP/IP address to allow it to communicate with the toolbox over Ethernet. server A PC, which gathers data over Ethernet from plant devices, and makes the data available to PC-based operator interfaces known as Viewers. shaft voltage suppressor The shaft voltage suppressor is a filter that conducts to ground the high frequency components of the induced voltages in the field current. signal The basic unit for variable information in the controller. simplex System with only one set of control and I/O boards. Contrast with redundant control systems. simulation Running the control system using a software model of the generator and exciter. SOE Sequence of Events, a high-speed record of contact closures taken during a plant upset to allow detailed analysis of the event. Static Exciter Produces a controlled dc field current without the use of a rotating generator. TCP/IP Communications protocols developed to inter-network dissimilar systems. It is a de facto UNIX standard, but is supported on almost all systems. TCP controls data transfer and IP provides the routing for functions. TMR Triple Modular Redundancy. An operation that uses three sets of control and I/O (channels M1, M2, and C) and votes the results. viii • Glossary of Terms GEH-6632 EX2100 User’s Guide toolbox A Windows NT -based software package used to configure the EX2100 and Mark VI turbine controller. under-excitation limit (UEL) UEL software functions to prevent generator over-heating caused by under excitation. unit data highway (UDH) Connects the EX2100, Mark VI turbine controllers, LCI, PLCs, and other GE provided equipment to the HMI Servers; runs at 10/100 Mbaud and supports Peer-toPeer communications. V/Hz V/Hz is the ratio of generator voltage to the frequency; this is limited to prevent overfluxing the generator. VME board Versa Module Eurocard, a European standard for printed circuit boards and backplane. warm backup Two bridges are connected to the field but only one is actively producing power. The other bridge does not receive gating pulses until it is required to take over from the active bridge. Windows NT Advanced 32-bit PC operating system from Microsoft. EX2100 User’s Guide GEH-6632 Glossary of Terms • ix Notes x • Glossary of Terms GEH-6632 EX2100 User’s Guide Index A ac disconnect 1-5, 2-5 Ac Line-to-Line Filters 2-1, 2-8 Ac to Dc Converter 1-6, 2-14, 3-1, 3-9, 3-11, B-1 ACLA (see Application Control Layer Module) Analog I/O 4-1, 4-2 Analog Input 4-1, 4-3 Application Control Layer Module 1-6, 2-11, 2-13, 214, 3-1, 3-2, 3-4, 4-19, 4-20 AUTO REF (see Auto Reference) Auto Reference 2-1, 2-20 Automatic Voltage Regulator 2-1, 2-20, 2-21, 3-4 auxiliary cabinet 1-5, 1-7, 2-5, 2-8, 2-15, 4-7, B-2 Auxiliary Cabinet 2-1, 2-8, 3-9, 4-16 Ac Line-to-Line Filters 2-1, 2-8 De-excitation Module 2-1, 2-8, 3-1, 3-6 – 3-8, 3-10, 3-11, 4-11 Field Flashing Module 2-1, 2-9 Field Ground Detector 2-1, 2-9, 3-7, 4-1, 4-14, 4-15 High Voltage Interface 2-1, 2-9 Shaft Voltage Suppressor 2-1, 2-9, 4-1, 4-18 Auxiliary power source 2-2 AVR (see Automatic Voltage Regulator) AVR Setpoint 2-1, 2-20 B bridge 1-2, 1-5, 1-6, 2-2, 2-5 – 2-9, 2-11, 2-14, 2-19, 3-1, 3-2, 3-5 –3-7, 4-3, 4-8, 4-9, 4-16, B-1, B-2 Bridge and Protection Boards and Modules EDEX 2-1, 2-8, 3-1, 3-6 – 3-8, 3-10, 3-11, 4-11 EGDM 2-1, 2-9, 2-15, 3-1, 3-4, 3-7 – 3-11, 4-14 EGPA 2-1, 2-5, 2-6, 2-11, 2-14, 3-1, 3-4, 3-5, 3-7, 3-9 EXAM 2-1, 2-9, 2-15, 3-1, 3-7 – 3-10 EXCS 3-1, 3-7 Bridge Rectifier 2-5 C Cabinet Dimensions & Weight 1-7, B-3 EX2100 User’s Guide GEH-6632 Cell Snubbers 2-5 communication 1-2, 1-5, 2-11, 2-13, 3-4, 4-19, 4-20, 5-6 Compound power source 2-2 contact input 1-7, 3-4 – 3-6, 4-4, B-2 contact output 1-7, 3-5, 3-6, 4-4, B-2 control 1-1, 1-2, 1-5 – 1-7, 2-1 – 2-4, 2-6, 2-8 – 2-11, 2-13, 2-14, 2-17, 2-19, 2-20, 2-21, 3-1, 3-2, 3-4 – 3-9, 3-11, 4-3, 4-4, 4-8, 4-11, 4-14, 4-16, 4-19, 5-1, 5-2, B-3 Control Boards ACLA 1-6, 2-11, 2-13, 2-14, 3-1, 3-2, 3-4, 4-19, 4-20 DSPX 1-6, 2-11, 3-1, 3-2, 3-4, 3-8, 4-14, 4-20, 5-13 EBKP 3-1, 3-2, 3-6, 3-11, 4-8 EISB 2-11, 3-1, 3-2, 3-4, 3-6, 3-8, 4-8 EMIO 2-11, 3-1, 3-2, 3-4 – 3-6, 4-3, 4-4, 4-16, 4-17 ESEL 2-6, 2-11, 2-14, 3-1, 3-2, 3-4, 3-5, 3-7 control cabinet 1-5, 2-9, 2-10, 3-11, 4-3 Control Cabinet 2-1, 2-10 Control Module 2-1, 2-11 Control Power Supplies 2-1, 2-14 Diagnostic Interface 1-1, 2-1, 2-2, 2-10, 5-1 Redundant Control System 2-1, 2-13 Simplex Control System 2-1, 2-12 control module 1-2, 2-6, 2-11, 2-14, 3-4, 4-14, 4-16 Control Module 2-1, 2-11 Control power supplies 2-2 Control Power Supplies 2-1, 2-14 Control Scheme 2-18 Control System Toolbox 1-2, 1-6, 1-8, 2-2, 2-17, 4-1, 4-20 Connection 4-1, 4-20 Controller C 1-2, 2-11, 2-13, 2-14, 3-2, 3-4, 3-5, 3-7 – 3-9, 3-11, 4-3, 4-14, 4-20, M1 1-2, 2-11, 2-13, 2-14, 3-2, 3-4, 3-5 – 3-9, 3-11, 4-3, 4-14, 4-20 M2 1-2, 2-11, 2-13, 2-14, 3-2, 3-4, 3-5 – 3-9, 3-11, 4-3, 4-14, 4-20 cooling fans 1-5, 2-2, 3-9 Crowbar 2-2, 3-6, 3-7, 3-10, 3-11, 4-1, 4-14, 4-18 Crowbar module 2-2, 3-7, 3-11 Current Shunt 2-6 Current transformers 1-7, B-2 Customer Contact I/O 4-1, 4-4 D DACA (see Ac to Dc Converter) Data Highway Connections 4-1, 4-19 dc contactors 1-5 Dc Field Flashing Settings 4-1, 4-16 de-excitation 1-2, 1-5, 2-5, 2-8, 3-4 – 3-6, 3-8, 3-11, 4-11, 4-14 De-excitation 2-1, 2-2, 2-7, 2-8, 4-11 Index • i De-Excitation 3-7, 3-11, 4-1, 4-11 – 4-13 Crowbar 2-2, 3-6, 3-7, 3-10, 3-11, 4-1, 4-14, 4-18 Field Flashing 2-1, 2-9, 3-2, 4-1, 4-16, 4-17 Field Ground Detector 2-1, 2-9, 3-7, 4-1, 4-14, 4-15 Shaft Voltage Suppressor 2-1, 2-9, 4-1, 4-18 De-excitation module 2-2, 2-8 De-excitation Module 2-1, 2-8, 3-1, 3-6 – 3-8, 3-10, 3-11, 4-11 Diagnostic Interface 1-1, 2-1, 2-2, 2-10, 5-1 Alternate Status Screen 5-1, 5-8 Changing Display 5-1, 5-7 Editing Parameters 5-1, 5-10, 5-15 Faults 5-1, 5-9 Keypad 2-10, 5-1 Protecting the Keypad 5-1, 5-14 Reading the Display 5-1, 5-5, 5-9 Reading the Meters 5-1, 5-8 Status Screen 5-1, 5-3, 5-5, 5-8 Using the Menus 5-1, 5-9 Using the Pushbuttons 5-1, 5-2 Diagnostic Interface (keypad) 1-1, 2-1, 2-2, 2-10, 3-2, 3-4, 5-1, 5-2, 5-5, 5-6, 5-8, 5-9, 5-10, 5-13 – 5-15 Digital Signal Processor Control Board 1-6, 2-11, 3-1, 3-2, 3-4, 3-8, 4-14, 4-20, 5-13 Document Distribution 1-1, 1-8 DSPX (see Digital Signal Processor Control Board) Dual Control System Configurations 2-4 E EACF (see Exciter AC Feedback Board) EBKP (see Exciter Backplane) ECTB (see Exciter Contact Terminal Board) EDCF (see Exciter DC Feedback Board) EDEX (see De-excitation Module) EDEX (see Exciter De-excitation Board) EGDM (see Exciter Field Ground Detector Module) EGPA (see Exciter Gate Pulse Amplifier Board) EISB (see Exciter ISBus Board) EMIO (see Exciter Main I/O Board) EPBP (see Exciter Power Backplane) EPCT (see Exciter PT/CT Board) EPDM (see Exciter Power Distribution Module) EPSM (see Exciter Power Supply Module) ESEL (see Exciter Selector Board) Ethernet 1-2, 2-11, 2-13, 3-4, 3-10, 4-19, 4-20 EXAM (see Exciter Attenuator Module) EXASP (see AVR Setpoint) Exciter AC Feedback 3-5, 3-7, 3-11, 4-1, 4-7, 4-8 Exciter AC Feedback Board 2-9, 3-1, 3-4, 3-5, 3-7, 4-3, 4-8 Exciter Attenuator Module 2-1, 2-9, 2-15, 3-1, 3-7 – 3-9, 3-10 Exciter Backplane 3-1, 3-2, 3-6, 3-11, 4-8 Exciter Conduction Sensor Board 3-1, 3-7 Exciter Configurations 2-1, 2-3 ii • Index Exciter Contact Terminal Board 1-7, 2-15, 3-1, 3-4 – 3-6, 3-10, 3-11, 4-4, B-2 Exciter DC Feedback 3-5, 3-6, 3-11, 4-1, 4-8 Exciter DC Feedback Board 2-6, 2-9, 2-13, 3-1, 3-4 – 3-6, 3-10, 3-11, 4-8 Exciter Gate Pulse Amplifier Board 2-1, 2-5, 2-6, 2-11, 2-14, 3-1, 3-4, 3-5, 3-7, 3-9 Exciter Internal I/O 4-1, 4-8 Exciter AC Feedback 3-5, 3-7, 3-11, 4-1, 4-7, 4-8 Exciter DC Feedback 3-5, 3-6, 3-11, 4-1, 4-8 Field Current Feedback 4-9 Field Voltage Feedback 4-9 Exciter ISBus Board 2-11, 3-1, 3-2, 3-4, 3-6, 3-8, 4-8 Exciter Main I/O Board 2-11, 3-1, 3-2, 3-4 – 3-6, 4-3, 4-4, 4-16, 4-17 Exciter Power Backplane 2-14 – 2-16, 3-1, 3-8, 3-9, 3-11 Exciter Power Distribution Module 2-14, 2-16, 3-1, 3-7, 3-9, 3-11, 4-6 Exciter Power Supply Module 2-12, 2-14, 3-1, 3-9, 3-11 Exciter PT/CT Board 2-13, 2-17, 3-1, 3-4, 3-5, 4-3 Exciter Selector Board 2-6, 2-11, 2-14, 3-1, 3-2, 3-4, 3-5, 3-7 Exciter Software Auto Reference 2-1, 2-20 Automatic Voltage Regulator 2-1, 2-20, 2-21, 3-4, 5-4 AVR Setpoint 2-1, 2-20 Field Current Regulator 2-1, 2-21, 3-2 Field Voltage Regulator 2-1, 2-20, 2-21, 3-2, 5-4, 5-8 Manual Reference 2-1, 2-21 Power System Stabilizer 2-1, 2-17, 2-20, 3-4 Under Excitation Limiter 2-1, 2-20, 3-4, 5-6, B-2 Exciter Terminal Board 2-7, 2-14, 2-15, 3-1, 3-4 – 3-6, 3-8 – 3-11, 4-11, 4-16, 4-17 EXCS (see Exciter Conduction Sensor Board) EXTB (see Exciter Terminal Board) F FCR (see Field Current Regulator) Field Current Feedback 4-9 Field Current Regulator 2-1, 2-21, 3-2 field flashing 1-5, 2-8, 2-9, 3-4, 3-6, 4-16 Field flashing module 2-2 Field Flashing Module 2-1, 2-9 Field Ground Detector 2-1, 2-9, 3-7, 4-1, 4-14, 4-15 Field Ground Detector Module 2-1, 2-9, 2-15, 3-1, 3-4, 3-7 – 3-11, 4-14 Field Voltage Feedback 4-9 Field Voltage Regulator 2-1, 2-20, 2-21, 3-2, 5-4, 5-8 Flashing Control 4-1, 4-16 Free Wheeling Diode 2-1, 2-7 FVR (see Field Voltage Regulator) GEH-6632 EX2100 User’s Guide G O Gate Pulse Amplifiers 2-1, 2-6 Generator Current Measurement 4-3 Generator Voltage Measurement 4-3 operator interface 1-2, 2-10 H PCM (see Power Conversion Module) Potential transformers 1-7, B-2 Power Connections 4-1, 4-2 power conversion cabinet 1-5, 2-8 Power Conversion Cabinet 2-1, 2-5, 4-11 Free Wheeling Diode 2-1, 2-7 Gate Pulse Amplifiers 2-1, 2-6 Main Dc Contactors 2-1, 2-7 Manual Ac Disconnect 2-1, 2-5 Power Converter Module 1-6, 2-1, 2-5 power conversion module 1-2, 1-6, 1-7, 2-1, 2-2, 2-5, 3-5, 3-7, 4-14, B-1 – B-3 Power Conversion Module 1-2, 1-6, 1-7, 2-1, 2-2, 2-5, 3-5, 3-7, 4-14, B-1, B-2, B-3 Power Converter Module 1-6, 2-1, 2-5 Power potential transformer 1-2, 2-2, 2-5, 2-9, 3-7, 4-3, 4-14 Power Potential Transformer 4-1, 4-3 power source 1-2, 3-7 Power Supply Boards DACA 1-6, 2-14, 3-1, 3-9, 3-11, B-1 EPBP 2-14 – 2-16, 3-1, 3-8, 3-9, 3-11 EPDM 2-14, 2-16, 3-1, 3-7, 3-9, 3-11, 4-6 EPSM 2-12, 2-14, 3-1, 3-9, 3-11 Power Supply Inputs 4-1, 4-6 Power System Stabilizer 2-1, 2-17, 3-4 PPT (see Power potential transformer) PPT (see Power Potential Transformer) PSS (see Power System Stabilizer) Hardware Overview 1-1, 1-5 High Voltage Interface 2-1, 2-9 HMI Mark VI 2-1 Toolbox 2-1, 4-20 HMI (see Human Machine Interface) How to Get Help 1-1, 1-8 Human Machine Interface 1-2, 2-1, 2-20, 2-21, 3-4, 4-19 Mark VI 2-1 Toolbox 2-1, 4-20 HVI (see High Voltage Interface) I I/O 1-1, 1-5, 1-6, 2-2, 2-10, 2-11, 3-1, 3-2, 3-4, 3-5, 3-9, 3-11, 4-1, 4-5, 5-1, 5-8 I/O Terminal Boards EACF 2-9, 3-1, 3-4, 3-5, 3-7, 4-3, 4-8 ECTB 1-7, 2-15, 3-1, 3-4 – 3-6, 3-10, 3-11, 4-4, B-2 EDCF 2-6, 2-9, 2-13, 3-1, 3-4 – 3-6, 3-10, 3-11, 4-8 EPCT 2-13, 2-17, 3-1, 3-4, 3-5, 4-3 EXTB 2-7, 2-14, 2-15, 3-1, 3-4 – 3-6, 3-8 – 3-11, 4-11, 4-16, 4-17 K Keypad 1-1, 2-10, 5-2, 5-7, 5-14, 5-15 P R Leg Reactors 2-5 Line Filter Connections 4-1, 4-7 Line-to-line filters 2-2 RAM 1-6 Ratings and Specifications 1-1 Redundant ac source 2-2 Redundant Control System 2-1, 2-13 Related Documents 1-1, 1-8 M S Main Dc Contactors 2-1, 2-7 Manual Ac Disconnect 2-1, 2-5 MANUAL REF (see Manual Reference) Manual Reference 2-1, 2-21 Mark VI HMI 2-1 Microprocessor-based controllers ACLA 1-6, 2-11, 2-13, 2-14, 3-1, 3-2, 3-4, 4-19, 4-20 DSPX 1-6, 2-11, 3-1, 3-2, 3-4, 3-8, 4-14, 4-20, 5-13 Multibridge configuration 2-2 SCR 1-2, 1-5, 2-5 – 2-8, 3-2, 3-5 – 3-8, 4-8, 4-9, 4-11 SCR De-excitation Module 2-8 shaft voltage suppression 1-5, 2-8 Shaft voltage suppressor 2-2 Shaft Voltage Suppressor 2-1, 2-9, 4-1, 4-18 Simplex Control Configurations 2-3 Simplex Control System 2-1, 2-12 Software Overview 1-1, 1-6 Status Screen 5-1, 5-3, 5-5, 5-8 L EX2100 User’s Guide GEH-6632 Index • iii T Technical Characteristics 1-1, 1-6 Thyrite 2-8, 4-18 TMR (see Triple Modular Redundant) Toolbox (see Control System Toolbox) Triple Modular Redundant 2-2, 2-14 U UDH (see Unit Data Highway) UEL (see Under Excitation Limiter) Under Excitation Limiter 2-1, B-2 Unit Data Highway 1-2, 4-19 W Warm backup bridge configuration 2-2 Warranty and Renewal Parts 1-1, A-1 iv • Index GEH-6632 EX2100 User’s Guide *(,QGXVWULDO6\VWHPV *HQHUDO(OHFWULF&RPSDQ\ 5RDQRNH%OYG ZZZ*(LQGXVWULDOFRP 6DOHP9$86$ ">
Advertisement
Key features
- Robust voltage regulation capabilities
- Reactive power control for power factor correction
- Comprehensive protection functions to safeguard your generator
- Advanced diagnostics and monitoring for proactive maintenance
- User-friendly interface for ease of operation and configuration
- Compact design for space-saving installation
- Compatible with a variety of generators and applications
- Backed by GE's expertise and industry-leading support
Frequently asked questions
The EX2100 is compatible with a wide range of synchronous generators, including those from GE and other manufacturers.
The EX2100 offers a number of benefits, including improved voltage regulation, enhanced reactive power control, comprehensive protection functions, advanced diagnostics and monitoring, user-friendly interface, compact design, and compatibility with a variety of generators and applications.
The EX2100 should be installed by a qualified electrician in accordance with the instructions provided in the user's guide.