Hearth and Home Technologies MTVERNINSAE

Add to my manuals
52 Pages

advertisement

Hearth and Home Technologies MTVERNINSAE | Manualzz
R
MT VERNON PELLET INSERT
ADVANCED ENERGY (AE)
Owner’s Manual
Installation and Operation
Tested and
Listed by
Portland
Oregon USA
O-T L
C
US
OMNI-Test Laboratories, Inc.
Models:
MTVERNINSAE-MBK
MTVERNINSAE-PMH
MTVERNINSAE-CSB
MTVERNINSAE-CWL
NOTICE
• Important operating and • Read, understand and • Leave this manual with
follow these instrucparty responsible for use
maintenance instructions
for
safe
installaand operation.
tions included.
tion and operation.
WARNING
Please read this entire manual
before installation and use of this
pellet fuel-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
• Do not overfire - If any external part starts to
glow, you are overfiring. Reduce feed rate.
Overfiring will void your warranty.
• Comply with all minimum clearances to combustibles as specified. Failure to comply may
cause house fire.
WARNING
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
CAUTION
CAUTION
Tested and approved for wood pellets, shelled field
corn, wheat and black oil sunflower seeds. Burning
of any other type of fuel voids your warranty.
www.quadrafire.com
T
O
N RD
O A
D SC
I
D
DO NOT DISCARD THIS MANUAL
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national
codes and regulations.
• Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance,
you have our assurance of commitment to quality, durability, and performance.
our stoves, inserts and fireplaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are hand-finished for lasting
beauty and enjoyment. Our pledge to quality is completed
as each model undergoes a quality control inspection.
This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation of
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Quadra-Fire.
LABEL LOCATION: On Beaded Chain on e behind Right Side Panel
CAUTION:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may
result in emissions products’ combustion from the hopper under certain conditions. Maintain hopper seal in
good condition. Do not overfill hopper.
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE
DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES
INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter,
sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
ATTENTION:
SERIAL NO. / NUMÉRO DU SÉRIE
SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ
007002
R
Report / Rapport
#061-S-69-6
US
Mt. Vernon Pellet Insert AE
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans
Installation. This appliance has been tested and listed for use in Manufactured l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage
Homes in accordance with OAR 814-23-9000 through 814-23-909.
dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
Tested to: ASTM E1509-04, ULC S628, ULC/ORD-C1482-M1990 Room
Heating Pellet Burning Type, (UM) 84-HUD FOR USE ONLY WITH
PELLETIZED WOOD. SEE OWNER’S MANUAL FOR OTHER FUEL OPTIONS.
Input Rating: 60,000 BTU/HR.
Electrical Rating: 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.
Route power cord away from unit. Do not route cord under or in front of
appliance.
DANGER: Risk of electrical shock. Disconnect power supply before
servicing.
Replace glass only with 5mm ceramic available from your dealer.
To start, set thermostat above room temperature, the stove will light
automatically. To shutdown, set thermostat to below room temperature.
For further instruction refer to owner's manual.
Keep viewing and ash removal doors tightly closed during operation.
A
M
Testé à: ASTM #1509-04, ULC S628, ULC/ORD-C1482-M1990 Room Heating. Pellet
Burning Type, UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS. VOIR LE
MANUAL DU PROPRIÉTAIRE POUR D’AUTRES OPTIONS DE CARBURANT.
Puissance de Rendement: 60,000 BTU/HR
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps,
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous
de l'appareil.
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact
avant le service. Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible
chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le
poêle s'allumera automatiquement. Pour éteindre, descendre la température du thermostat en
dessous de la température de la pièce. Pour des instructions supplémentaires, référez vous au
manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres fermées
hermétiquement durant l'opération.
L
P
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
AS A BUILT-IN UNIT
A
B
C
SIDE WALL
MUR LATÉRAL
D
E
Top of Hopper
Side of Outside Skin
Back of Hopper
Top/Rear Vent
Top/Rear Vent
Top Vent
Rear Vent
Vent Pipe to Combustible Top/Rear Vent
Cast Side to Side Wall Top/Rear Vent
3 in. (76mm)
2 in. (51mm)
7.5 in. (191mm)
2.75 in. (70mm)
3 in. (76mm)
6 in (152mm)
S
Garniture
de façade
MANTEL MANTEAU
See manual for mantel clearances.
Face Trim
B
C
A
E
Test Lab &
Report No.
COMME APPAREIL INSÉRÉ
A
C
D
B
B
C
E
0 in. Clearance To Exposed Section and Face Trim / Espace libre
de 0 mm de la section exposée et de la garniture du devant.
A Des Conduits Du Haut/Arrières:
B Des Conduits Du Haut/Arrières:
C Des Conduits Du Haut:
Arrières
D Des Conduits Arrières/Du Haut
E Côté de Fonte au Mur Latéral:
3 in. (76mm)
2 in. (51mm)
2.75 in. (70mm)
7.5 in. (191mm)
3 in. (76mm)
6 in. (152mm)
Masonry or Zero Clearance Dégagement de la maçonnerie ou Dégagement zéro*
6 in.
0 in.
0 in.
6 in.
6 in.
152mm
0mm
0mm
152mm
152mm
de l’ouverture de la porte
DO NOT REMOVE THIS LABEL
2008
Fabriqué par:
Model Name
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
A Insert side to combustible / Insérez le côté au mur combustible latéral
B Insert top to face trim / Insérez le dessus de la garniture de façade
C Insert side to face trim / Insérez le côté de la garniture de façade
D Hearth extension from door opening / Prolongement d’âtre depuis l’ouverture de la porte devant
E Hearth extension from side of door opening / Prolongement d’âtre depuis le côté
D
Manufactured by:
E
Serial Number
2008
2010
JAN
FEB
NE PAS ENLEVER L'ÉTIQUETTE
MAR
APR
MAY
JUNE
JULY
AUG
SEPT
OCT
NOV
DEC
Mfg Dates
1445 Highway North, Colville, WA 99114
www.quadrafire.com
Page 2
Made in U.S.A.
Fait Aux États-Unis
7036-135E
7036-137
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
TABLE OF CONTENTS
Section 7: Appliance Set-Up (Cont’d)
Section 1: Listing and Code Approvals
A.
B.
C.
D.
E.
E.
F.
G.
H.
Appliance Certifications ......................4
Mobile Home Approved ......................4
Glass Specifications ............................4
Electrical Rating ..................................4
BTU & Efficiency Specifications ..........4
Panel & Cast Trim Set ........................20
Panel & Trim Set, Basic ......................20
Log Set Placement ..............................21
Wall Control Thermostat ......................22
Section 8: Operating Instructions
Section 2: Getting Started
A.
B.
C.
D.
E.
Fuel Size, Material & Storage .............23
General Operation Information ...........23
Before Your First Fire .........................24
Starting Your First Fire........................24
Fire Characteristics & Flame
Height Adjustment ..............................25
F. Battery Back-Up System ....................25
G. Ignition Cycles ....................................25-26
H. Quick Start Quide ...............................27-28
I. Frequently Asked Questions...............29
A. Design, Installation & Location
Considerations ....................................5
B. Locating Your Appliance & Chimney ..6
C. Wall Control Thermostat .....................6
D. Draft ....................................................6
F. Negative Pressure ..............................6
F. Fire Safety ..........................................7
G. Tools & Supplies Needed ...................7
H. Inspect Appliance, Components
and Pre-Check List .............................7
Section 9: Troubleshooting ............................30
Section 3: Dimensions & Clearances
A. Appliance Dimensions ........................8
B. Clearances to Combustibles
As A Built-In Rear & Vertical ...............9-10
C. Clearances to Combustibles,
Masonry & Zero Clearance Fireplace ..10
D. Floor Protection ..................................10
E. Minimum Opening for Masonry
& Zero Clearance Fireplace ...............10
F. Mantel Projections ..............................10
G. Removing Metal Floor of Factory
Built Fireplace .....................................11
Section 10: Maintaining & Servicing Appliance
A. Proper Shutdown Procedure ...............31
Quick Reference Maintenance Chart ..... 31
C. General Maintenance & Cleaning .......32-35
D. High Ash Fuel Content Maintenance ..36
E. Baffle Removal ....................................36
F. Glass Replacement .............................37
B.
Section 11: Reference Material
Section 4: Vent Information
A. Venting Termination Minimum
Requirements .....................................12
B. Chimney & Exhaust Connections .......13
C. Equivalent Feet of Pipe.......................13
D. Pipe Selection Chart ...........................14
A.
B.
C.
D.
E.
F.
G.
H.
Component Functions.........................38-39
Component Locations .........................40
Exploded Views ..................................41-42
Service Parts & Accessories...............43-46
Service & Maintenance Log ................47-48
Homeowner’s Log ...............................49
Warranty Policy ...................................50-51
Contact Information ............................52
Section 5: Venting Systems
A. Direct Connect without Outside Air .....15
B. Direct Connect witht Outside Air .........15
C. Full Reline with Outside Air .................16
Section 6: Mobile Home Installation ............17
Section 7: Appliance Set-Up
A.
B.
C.
D.
Leveling System .................................18
Outside Air Kit .....................................18
Hearth Support for ZC Fireplace .........19
Removal of Cast Sides .......................19
September 1, 2008
7036-135E
Page 3
R
Mt. Vernon Pellet Insert (AE)
1
Listing and Code Approvals
E. BTU & Efficiency Specifications
A. Appliance Certification
MODEL:
Mt. Vernon Pellet Insert AE
Emissions Rating: EPA Compliant
LABORATORY:
OMNI Test Laboratories, Inc
*BTU Output:
14,620 - 60,200
REPORT NO.
061-S-69-6
Efficiency:
81.4% - 83.6%
TYPE:
Solid Fuel Room Heater/Pellet Type
Insert
Heating Capacity:
2,400 - 3,800 square feet depending on climate zone
STANDARD:
ASTM E1509-04, ULC S628-93 and
ULC/ORD-C1482-M1990 Room Heater
Pellet Fuel Burning Type and (UM) 84HUD, Mobile Home Approved
Hopper Capacity:
56 lbs
Fuel:
Pellets, Shelled Field Corn, Wheat
and Black Sunflower Seeds
Complies with Part 15 of FCC Rules.
Operation is subject to the following
two conditions: (1) this device may not
cause harmful interference, and (2) this
device must accept any interference
received, including interference that
may cause undesired operation.
Shipping Weight:
425 lbs.
FCC
*BTU output will vary, depending on the brand of fuel you
use in your appliance. Consult your Quadra-Fire dealer
for best results.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifications and/or price without notice.
B. Mobile Home Approved
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is provided.
The structural integrity of the mobile home floor, ceiling, and
walls must be maintained. The appliance must be properly
grounded to the frame of the mobile home and use only listed
pellet vent, Class “L” or “PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile
home installation.
C. Glass Specifications
This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
NOTE: This installation must conform with local codes. In
the absence of local codes you must comply with the ASTM
E1509, ULC S628-93 (UM) 84-HUD, ULC/ORD-C-1482.
D. Electrical Rating
115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps
Page 4
7036-135E
September 1, 2008
R
2
Mt. Vernon Pellet Insert (AE)
Getting Started
A. Design, Installation & Location Considerations
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
1. Appliance Location
• Windows
NOTICE: Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
•
Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation
Consideration must be given to:
• Safety, convenience, traffic flow
• Placement of the chimney and chimney connector.
• If you are not using an existing chimney, place the appliance where there will be a clear passage for a factorybuilt listed chimney through the ceiling and roof.
• Installing an optional outside air kit would affect the location of the vent termination.
Recommended Location:
• Above peak
• Air Intakes
• Air Conditioner
• Overhang, soffits, porch roofs, adjacent walls
• Landscaping, vegetation
When locating vent and venting termination, vent above
roof line when possible.
Warning! Risk of Fire Damaged parts could impair safe
operation. Do NOT install damaged, incomplete or substitute
components.
CAUTION! If burning shelled field corn, you must use approved venting specifically designed for corn to prevent corrosion or degradation. Follow the instructions from the venting
manufacturer.
NOTICE: Locating the appliance in a location of
considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near:
•
Frequently open doors
•
Central heat outlets or returns
Recommended Location:
• Above peak
• Inside heated space
Marginal Location:
• Wind loading possible
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Recommended:
• Insulated exterior chase
in cooler climates
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
Multi-level Roofs
NOT recommended:
Outside Air Intake
on leeward side
Figure 5.1
September 1, 2008
7036-135E
Page 5
R
Mt. Vernon Pellet Insert (AE)
B. Locating Your Appliance & Chimney
E. Negative Pressure
Location of the appliance and chimney will affect
performance.
WARNING! Risk of Asphyxiation! Negative pressure can
cause spillage of combustion fumes and soot.
•
•
Install through the warm airspace enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die-down of the fire.
Penetrate the highest part of the roof. This minimizes the
effects of wind loading.
•
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
•
Minimize the use of chimney offsets.
•
Consider the appliance location relative to floor and ceiling
and attic joists.
•
Take into consideration the termination requirements on
Page 12.
CAUTION
Negative pressure results from the imbalance of air available for the appliance to operate properly. It can be strongest in lower levels of the house.
Causes include:
•
Exhaust fans (kitchen, bath, etc.)
•
Range hoods
•
Combustion air requirements for furnaces, water heaters
and other combustion appliances
•
Clothes dryers
•
Location of return-air vents to furnace or air
conditioning
•
Imbalances of the HVAC air handling system
•
Upper level air leaks such as:
• Do NOT connect this unit to a chimney flue servicing
another appliance.
• Do NOT connect to any air distribution duct or system.
- Recessed lighting
- Attic hatch
- Duct leaks
To minimize the effects of negative air pressure:
C. Wall Control, Thermostat
The wall control’s location will have some affect on the
appliance’s operation.
• When located close to the appliance, it may require a
slightly higher temperature setting to keep the rest of
the house comfortable.
• When located in an adjacent room or on a different floor
level, you will notice higher temperatures near the appliance.
CAUTION! The wall control is an integral part of the
appliance. No other wall control or thermostat can be
substituted.
D. Draft
•
Install the outside air kit with the intake facing prevailing
winds during the heating season
•
Ensure adequate outdoor air for all combustion appliances
and exhaust equipment
•
Ensure furnace and air conditioning return vents are not
located in the immediate vicinity of the appliance
•
Avoid installing the appliance near doors, walkways or
small isolated spaces
•
Recessed lighting should be a “sealed can” design
•
Attic hatches weather stripped or sealed
•
Attic mounted duct work and air handler joints and seams
taped or sealed
Draft is the pressure difference needed to vent appliances
successfully. When an appliance is drafting successfully, all
combustion byproducts are exiting the home through the
chimney.
Considerations for successful draft include:
•
•
Preventing negative pressure
Location of appliance and chimney
NOTICE: Hearth & Home Technologies assumes no
responsibility for the improper performance of the chimney
system caused by:
• Inadequate draft due to environmental conditions
• Downdrafts
• Tight sealing construction of the structure
• Mechanical exhausting devices
Page 6
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
F. Fire Safety
G. Tools And Supplies Needed
To provide reasonable fire safety, the following should be
given serious consideration:
• Install at least one smoke detector on each floor of your
home.
• Locate smoke detector away from the heating appliance
and close to the sleeping areas.
• Follow the smoke detector manufacturer’s placement and
installation instructions and maintain regularly.
• Conveniently locate a Class A fire extinguisher to contend
with small fires.
•
In the event of a hopper fire:
• Evacute the house immediately.
• Notify fire department.
Tools and building supplies normally required
for installation, unless installing into an existing
masonry fireplace:
Reciprocating Saw
Safety Glasses
Channel Locks
Framing Square
Hammer
Electric Drill & Bits (1/4”)
Phillips Screwdriver
1/4” Self-Tapping Screws
Tape Measure
Plumb Line
May also need:
Level
Vent Support Straps
Framing Material
Venting Paint
Hi-temp Caulking Material
Gloves
H. Inspect Appliance & Components and
Pre-Use Check List
WARNING
1.
Place the appliance in a location near the
final installation area and follow the procedures below:
2.
Open the appliance and remove all the parts
and articles packed inside the Component
Pack.
Fire Risk.
•
Do not operate appliance before reading
and understanding operating instructions.
•
Failure to operate appliance properly may
cause a house fire.
Inspect all the parts and glass for shipping
damage. Contact your dealer if any irregularities are noticed.
Remove rubber band from ash pan installed for
shipping purposes only.
WARNING
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied with
unit).
• Do NOT Overfire
Or any such action that may cause a fire hazard.
September 1, 2008
3.
All safety warnings have been read and followed.
4.
This Owner’s Manual has been read.
5.
Floor protection requirements have been met.
6.
Venting is properly installed.
7.
The proper clearances from the appliance and
chimney to combustible materials have been
met.
8.
The masonry chimney is inspected by a professional and is clean, or the factory built metal
chimney is installed according to the manufacturer’s instructions and clearances.
9.
The chimney meets the required minimum
height.
10.
All labels have been removed from the glass
door.
11.
Plated surfaces have been wiped clean, if
applicable.
12.
Wall Control Thermostat has been installed.
13.
A power outlet is available nearby.
14.
A good quality surge protectory is highly recommended to protect the electronics.
7036-135E
Page 7
R
Mt. Vernon Pellet Insert (AE)
3
Dimensions and Clearances
A. Appliance Dimensions
32 in. (812mm)
23-7/8 in.
8-1/8 in.
(606mm)
(206mm)
15 in.
(382mm)
CL
2-3/8 in.
(59mm)
29-3/4 in.
(756mm)
23-7/8 in.
(605mm)
13-1/8 in.
(333mm)
26-1/4 in.
(667mm)
28-1/8 in.
(714mm)
Figure 8.1 - Top View
Figure 8.2 - Side View
36-5/8 in.
(929mm)
33 in.
(838mm)
34-7/8 in.
(886mm)
46-1/8 in.
(1171mm)
50 in. (1270mm)
Figure 8.3 - Front View with Basic Surround Panel Set
Page 8
Figure 8.4 - Front View with Cast Panel Set
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
B. Clearance To Combustibles, UL and ULC
Built-in Unit - Rear Vent
A
D
C
B
B
C
E
0 inch Clearance To Exposed Section And Face Trim
Figure 9.1
Location
Configuration
Inches
Millimeters
A
Top of Hopper
Top or Rent Vent
3
76
B
Side of Outside Skin
Top or Rear Vent
2
51
C
Back of Hopper
Top Vent
7-1/2
191
Rear Vent
2-3/4
70
D
Vent Pipe to Combustible
Top or Rear Vent
3
76
E
Cast Side to Side Wall
Top or Rear Vent
6
152
Built-in Unit - Rear Vent with Outside Air
WARNING
Fire Risk.
Comply with all minimum
clearances to combustibles as
specified.
Failure to comply may cause
house fire.
Top/Rear Vent
3 in. (76mm)
6 in
(152mm)
Back of Hopper
2.75 in. (70mm)
Outside Air
NOTE:
• Illustrations reflect typical installations
and are FOR DESIGN PURPOSES
ONLY.
• Illustrations/diagrams are not drawn to
scale.
• Actual installation may vary due to
individual design preference.
Figure 9.2
September 1, 2008
7036-135E
Page 9
R
Mt. Vernon Pellet Insert (AE)
E. Minimum Opening for Masonry and Zero
Clearance Fireplaces
Built-In Vertical
H
G
in
mm
F
I
in
mm
Figure 10.3
in
mm
se two
degree elbows to
clear heat shield and hopper
Location
Inches
Millimeters
F
Rear Width
24
610
G
Depth
15
381
H
Height
23-7/8
606
I
Front Width
34
864
Figure 10.1
C. Masonry and Zero Clearance Fireplaces
F. Mantel Projections
Side Wall
J
Face
Trim
Mantel
K
B
A
C
E
D
Figure 10.2
Location
Inches Millimeters
A
Insert side to combustible side wall
6
152
B
Insert top to max. 2-1/4 inch face trim
0
0
C
Insert side to max. 2-1/4 inch face trim
0
0
Figure 10.4
D. Floor Protection
Location
Inches
Millimeters
D
Floor protection hearth extension from
door opening
6
152
E
Floor protection to the side of door
opening
6
152
Page 10
The maximum mantel depth (J) is 12 inches (305mm) with
a minimum vertical height (K) of 12 inches (305mm).
However if your mantel has a depth of 10 inches (254mm)
then the vertical minimum height is 10 inches (254mm).
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
G. Removing Metal Floor of Factory-Built Firebox
•
•
•
The firebrick (refractory), glass doors, screen rails, screen
mesh and log grates can be removed from a factory-built
firebox in order to gain minimum insert opening requirements.
Any smoke shelves, shields and baffles may be removed
from a factory-built firebox if attached with mechanical fasteners.
Use 2 x 4 from insert
packaging to support insert
The metal floor of the factory-built firebox may be removed
to facilitate the installation of the insert only when a 1/4
inch (6mm) airspace is provided between the insert and
the floor of outer wrap.
The following is only one example as there are many different models of factory-built fireplaces.
Figure 11.3. If the floor is made of thin metal,
we recommend using the 2 x 4 from the insert
packaging to support the insert. The 2 x 4
may need to be cut to the appropriate size.
Starter hole
Keep sharp edge of
metal floor away from
power cord
Mark area of
floor to cut
Figure 11.1. Measure and mark the metal
floor for cutting. With a drill, make a starter
hole in each corner.
Figure 11.4. Place the insert into the factory-built firebox. Ensure that the power
cord can not be damaged by the sharp metal
edge. You may need to cut out a notch to
accomodate the cord.
Leveling Leg
Figure 11.2. Using a saws-all, cut out the
floor.
Figure 11.5. Ensure that the leveling leg is
positioned over the 2 x 4 before leveling the
insert.
September 1, 2008
7036-135E
Page 11
R
Mt. Vernon Pellet Insert (AE)
4
Vent Information
A. Venting Termination Minimum Requirements
V
N
V
Inside
N
orner
Electrical
Ser ice
N
V
N
V
G
V
A
D
O
V
L
P
C
V B
FIXED
CLOSED
V
F
FIXED
CLOSED
OPEN
V
B
OPEN
V
V
V Termination Cap
G
X Air Supply Inlet
M
I
A
B
B
Figure 12.1
H
E
G Gas Meter
V
X
J or
Restricted Area
All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below.
A
12 in.
Above Finish Grade (the grade surface
must be a non-combustible material
24 in.
Above grass, top of plants, wood or any other combustible
B
12 in.
48 in. no OAK
Open door or window: below or to the side
12 in.
36 in. no OAK
Clearance from any forced air intake of other appliance
B
12 in.
Open door or window: above
12 in.
Clearance horizontally from combustible wall
C
6 in.
Permanently closed window: above, below
or to the side
15 in.
Vented directly through a wall, minimum length of
horizontal pipe
D
18 in.
36 in. no OAK
Vertical clearance to a ventilated soffit
located above the terminal within a horizontal distance of 2 ft from the center-line
of the terminal
6 in. horizontal
12 in. vertical
Minimum horizontal or vertical terminations must
protrude from wall
NOTICE:
E
12 in.
Clearance to unventilated soffit
Do NOT Terminate Vent:
F
12 in.
Clearance to outside corner
•
G
12 in.
Clearance to inside corner
In any location that will allow flue gases or soot from entering or staining the building.
H
36 in.
Above gas meter/regulator measured from
horizontal center-line of regulator
•
In any location which could create a nuisance or hazard.
I
36 in. USA
72 in. Canada
Clearance to service regulator vent outlet
•
J
12 in.
48 in. no OAK
Clearance to non-mechanical air supply
inlet to the building or the combustions air
inlet to any other appliance
In any enclosed or semi-enclosed area such as a carport,
garage, attic, crawl space, under a sun deck or porch,
narrow walkway.
•
K
10 ft horizontal
3 ft vertical
Clearance to mechanical air supply
Closely fenced area, or any location that can build up
a concentration of fumes such as a stairwell, covered
breezeway, etc.
L
7 ft.
Above paved sidewalk, paved driveway
located on public property
M
12 in.
Under an open veranda, porch, deck or
balcony
N
See Note
below*
Electric service: above, below or to the
side (location must not obstruct or interfere
with access)
O
24 in.
Adjacent building, fences and protruding
parts of the structure
P
12 in.
Clearance above roof line for vertical
terminations
NOTICE:
Termination must exhaust above air inlet elevation.
*NOTE: Consult local building, fire officials or authorities having jurisdiction. Local codes or regulations may require different clearances.
Page 12
•
It is recommended that at least 60 inches (1524mm) of
vertical pipe be installed when appliance is vented directly
through a wall. This will create a natural draft, which will
help prevent the possibility of smoke or odor venting into
the home during a power outage.
•
It will also keep exhaust from causing a nuisance or hazard
by exposing people or shrubs to high temperatures.
•
The safest and preferred venting method is to extend the
vent vertically through the roof or above the roof.
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
B. Chimney and Exhaust Connection
1. Chimney & Connector: Use 3 or 4 inch (76-102mm)
WARNING
diameter type "L" or "PL" venting system. It can be vented
vertically or horizontally.
Fire Risk.
• Only LISTED venting components may be
used.
2. Mobile Home: Approved for all Listed pellet vent. Use
Listed double wall flue connector. A Quadra-Fire Outside
Air Kit must be used with manufactured home installations.
• NO OTHER vent components may be used.
Substitute or damaged vent components may
impair safe operation.
3. Residential: Use 24 gauge single wall flue connector or
Listed double wall flue connector to Class A Listed metal
chimneys, or masonry chimneys meeting International
Residential Code standards for solid fuel appliances.
WARNING
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
Vent surfaces get HOT, can cause burns
if touched. Non-combustible shielding or
guards may be required.
5. Secure exhaust venting system to the appliance with at
least 3 screws. Also secure all connector pipe joints with
at least 3 screws through each joint.
NOTE: All pipe must be welded seam pipe whenever
possible. Seal pipe joints with high temperature silicone
(500°F [260°C] minimum rated only).
NOTE: If burning shelled field corn, you must use
approved venting specifically designed for corn. Follow
the instructions from the venting manufacturer.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appliance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
C. Equivalent Feet of Pipe
The table below can help you calculate the equivalent feet
of pipe which is a method used to determine pellet vent size.
Figure 13.1.
Example of 3 Elbow-Rear Vent Termination Calculation
2 ft.
Pellet Venting
Component
# of
Elbows
90o Elbow or Tee
3
Feet of Multiplied
Pipe
By
45o Elbow
3 ft.
Equivalent
Feet
Equivalent Feet
Components
X
5
15
X
3
Horizontal Pipe
7
X
1
7
Vertical Pipe
2
X
0.5
1
Total Equivalent Feet
23
2 ft.
Note: This is a generic example and is not
intended to represent any specific fuel type.
2 ft.
Figure 13.1
September 1, 2008
7036-135E
Page 13
R
Mt. Vernon Pellet Insert (AE)
D. Pipe Selection Chart
WARNING
The chart will help you in determining proper venting size
according to the equivalent feet of pipe calculated in the Vent
Termination Calculaltion Table and the altitude above sea
level of this installation. See Figure 14.1.
Fire Risk.
Locate the calculated equivalent feet of pipe on the vertical
left side of the chart. Move to the right horizontally on the
chart until you reach your altitude above sea level.
• ALWAYS maintain specified clearances
around venting and firestop systems.
If you fall below the diagonal line, 3 or 4 inch (76 to 102mm)
pipe may be used. If it is anywhere above the diagonal line,
a 4 inch (102mm) diameter pipe is required.
Failure to keep insulation or other material
away from vent pipe may cause fire.
Do NOT pack insulation or other
combustibles between firestops.
• Install firestops as specified.
The chart reveals that a 90° elbow is 5 times as restrictive
to the flow of exhaust gases under positive pressure as one
foot of horizontal pipe, and a foot of horizontal pipe is twice
as restrictive as a foot of vertical pipe.
30
4 in. (102mm) Diameter Pipe Only
Example 1
20
Equivalent Pipe
Length In Feet
Example 2
10
3 in. or 4 in. (76mm or 102mm) Diameter Pipe
0
1
2
3
4
5
6
7
8
9
10
ALTITUDE IN THOUSANDS OF FEET
Figure 14.1
Example 1: If the equivalent length of pipe is 23 feet with altitude of
8,000 feet you must use 4 inch (102mm) diameter type “L” or “PL”
vent.
Example 2: If the equivalent length of pipe is 12 feet with altitude of
6,000 feet you may use 3 or 4 inch (76 to 102mm) diameter type “L”
or “PL” vent
Page 14
7036-135E
September 1, 2008
R
5
Mt. Vernon Pellet Insert (AE)
Venting Systems
A. Direct Connect Without Outside Air
B. Direct Connect With Outside Air
NOTE; Use metal plate
around exhaust vent pipe
and seal all edges with
non-flammable insulation
such as fiberglass, mineral
wool or ceramic material.
Do not use high temperature caulking materials to
seal any edge to prevent
future serviceability.
Outside Air
through
Rear Wall
Figure 15.2
Figure 15.1
CAUTION
NOTE:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
WARNING
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be 6 inch (152mm)
UL103 HT.
September 1, 2008
Never draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.
7036-135E
Page 15
R
Mt. Vernon Pellet Insert (AE)
CAUTION
C. Full Reline With Outside Air
NOTE: Check clearances carefully for this type of installation to ensure adequate room for outside air venting.
NOTE: In Canada only a full reline is allowed per ULC
S628, ORD ULC C1482-M1990.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fire officials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
in
mm
min above
in
mm
min below
NOT
se metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass mineral
wool or ceramic
Outside Air
Termination
at
himne Top
o not use high
temperature caulking materials to
seal an edge to
prevent future
serviceabilit
Outside Air
through
Rear Wall
Figure 16.1
Page 16
7036-135E
September 1, 2008
R
6
Mt. Vernon Pellet Insert (AE)
Mobile Home
A. Mobile Home Installation
You must use a Quadra-Fire Outside Air Kit for installation in a mobile home.
1.
An outside air inlet must be provided for the combustion
air and must remain clear of leaves, debris, ice and/or
snow. It must be unrestricted while the appliance is
in use to prevent room air starvation which causes
smoke spillage. Smoke spillage can also set off smoke
alarms.
2.
The combustion air duct system must be made of
metal. It must permit zero clearance to combustible
construction and prevent material from dropping into
the inlet or into the area beneath the dwelling and
contain a rodent screen.
3.
CAUTION
Maintain structural integrity of mobile home:
• Floor, wall, ceiling and/or roof.
Do NOT cut through:
• Floor joist, wall studs or ceiling trusses.
• Any supporting material that would affect the structural
integrity.
park Arrestor
The appliance must be secured to the mobile home
structure by bolting it to the floor (using lag bolts). Use
the same holes that secured the appliance to the shipping pallet.
4.
The appliance must be grounded with #8 solid copper
grounding wire or equivalent, terminated at each end
with an NEC approved grounding device.
5.
Refer to Clearances to Combustibles and floor protection requirements on pages 9 & 10 for listings to
combustibles and appropriate chimney systems.
6.
Use silicone to create an effective vapor barrier at
the location where the chimney or other component
penetrates to the the exterior of the structure.
7.
Follow the chimney manufacturer’s instructions when
installing the vent system for use in a mobile home.
8.
Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part
24.
torm
ap
ollar
Roof lashing
oist hield irestop
Approved lass L
or L ellet ent
Figure 17.1
WARNING
Installation must comply with Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
WARNING
Never install in a sleeping room.
September 1, 2008
7036-135E
Page 17
R
Mt. Vernon Pellet Insert (AE)
7
Appliance Set-Up
A. Leveling System
B. Outside Air Kit Instructions
The leveling bolts are located on the sides of the appliance,
front and rear. To access the bolts, remove the front access
panels. Reach in and turn the bolt to the desired height to
level the appliance.
Included in Kit: 2 wire ties, 1 collar assembly,
1 termination cap assembly, 1 trim ring, fasteners.
NOTE: 3 INCH ALUMINUM FLEX PIPE NOT INCLUDED.
Tools Needed: Phillips head screw driver; wire cutters;
hole saw or jig saw.
1. Measure distance from floor to air vent opening in appliance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 3-1/2 to 4 inch
(89-102mm) opening on inside wall and a 4 to 4-1/2
inch (102-114mm) opening on outside of house.
3. Use wire ties to secure flex pipe to collar assembly.
4. Slide trim ring over flex pipe and run pipe through wall.
5. Attach flex pipe (not included) to outside termination
cap with second wire tie.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
CAUTION
Leveling Bolts - 2 on each side
Figure 18.1
Never draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Collar
Wire Ties
3 inch Aluminum Flex
Pipe (not included)
Trim Ring
Termination Cap
Figure 18.2
Page 18
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
C. Hearth Support
Included in Kit: (1) bottom, (1) trim front, (2) trim sides, (2)
trim extensions
7. Place the assembled hearth support under the insert.
Lower the leveling bolts if necessary to keep the insert
level.
Tools Needed: Phillips head screw driver, measuring tape,
gloves
8. Open the door and attach the hearth support to the insert.
There are 9 attachment holes. Figure 19.3.
1. Remove contents from box and lay on protective surface
to avoid scratching the paint.
2. Lay front and sides face down. Bend the tabs down
toward the inside. Figure 19.1.
attachment holes - on
each side and in the front
3. The side pieces are shipped flat. It is must easier to flex
the sides into a bowed position before installing.
4. Lay the cast bottom face up. Attach the 2 sides FIRST and
then the front piece. Figure 19.2.
5. Turn the cast bottom right side up and attach the panel
extensions. Note the alignment hole.
6. Attach the appropriate footers depending on the panels
& trim set you are installing. The footers come in 2 sizes,
3 and 5 inches. Discard the footers not used.
Figure 19.3
D. Removal of Cast Sides
You will need to remove the cast sides in order to install
the panel and trim set.
1. There is a latch on the back side of the cast side in the
middle of the top opening of the cast side as indicated
in Figure 19.4.
Bend tabs down. Shipped
flat from the factory.
2. Place your fingers inside the opening and squeeze
the latch. The side can now be pulled toward you and
removed. Place on a protective surface so as not to
damage the finish.
3. To replace the side, set the bottom in first. Squeeze the
latch in an open position. Place the cast side into position and then release the latch. The latch hooks onto a
bracket to hold the side in place.
Figure 19.1
3 inch
high Set
Location of Latch
for Removing
Cast Sides
Attach Trim to Insert from
inside Insert.
5 inch
high Set
Lower the leveling
bolts if necessary to
keep the insert level
when installing the
Hearth Support.
3 in
Basic
Cast
5 in
Install Front Trim Last,
Corner Overlap Side
Trim Pieces
Figure 19.2
September 1, 2008
Attach Trim to Base
from underneath
Figure 19.4 - Shown with Cast Panel Set
7036-135E
Page 19
R
Mt. Vernon Pellet Insert (AE)
F. Panel & Trim Set, Basic
E. Panel and Trim Set - Cast
Included in Panel Kit: (2) side panels, left and right; (1)
panel top; (1) fastener package.
Included in Panel & Trim Kit: (2) corner brackets and set
screws; (1) trim set, 3 piece; (2) side panels; (1) top panel;
(4) screws.
Included in Cast Trim Kit: (2) cast trim legs, left and right; (1)
cast trim header; (2) cast trim footers, left and right; (1) fastener
package.
Tools Needed: Powered Phillips head screw driver
Tools Needed: Powered Phillips head screw driver
1. Remove contents from box being careful not to scratch or
damage the cast trim pieces.
2. Lay the panel set face down on protective covering to prevent
scratching the painted surface.
3. Secure the panel legs to top panel with the screws
provided.
4. Now bend the tabs down toward the backside of the panel
set, 5 on top and 2 on each leg. Leave the panel set face
down. Figure 20.1.
1. Secure the top panel to the panel sides with the
screws provided. Figure 20.3.
2. Assemble the trim with the (2) corner brackets
provided. Figure 20.4.
3. Remove the 2 cast sides and slide the assembled
trim over the assembled panel set. See Figure 19.4
on page 19.
4.
Carefully slide panel and trim over the top of the insert
into place matching the mounting holes on the panel
with the mounting holes on the insert. Secure with
screws provided. Figure 20.5.
5. Place the corresponding cast trim pieces ( 2 cast trim legs
and 1 cast trim header) underneath the panel set, also face
down.
6. Place washer provided over tab and secure the trim and panel
together with screw. Continue for all tabs.
Back of Top Panel
Screws
7. Secure cast footers with screws.
8. Remove both left and right cast sides from insert. See Figure
19.4 page 19.
Back of Side Panel
9. Slide panel and trim over the top of the insert into place
matching the mounting tabs on the panel with the slots on
the insert.
2. Bend tabs down
Figure 20.3
1. Screw panels
together
1. Screw panels
together
2. Bend tabs
down
Figure 20.4
3. Install Cast Trim Header
Figure 20.1
Shown with trim installed on panel set
Figure 20.2- Completed View
Page 20
Figure 20.5
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
G. Optional Log Set Placement Instructions
2 PIECE LOG SET INSTALLATION
1. Place the left log as shown. There are 2 indentations in
the bottom of the log to fit over the screw heads in the
firebox. Figures 21.1 and 21.2.
2. Place the right log in front of the 2 screw heads in the
firebox. Figures 21.3 & 21.4.
Right Log
CAUTION
Logs are FRAGILE. Use extreme care when handling or
cleaning logs.
Log rests in front of screws
Figure 21.3
Left Log
Log fits over screws
Figure 21.1
Figure 21.4
Log has indentations on the
bottom to fit over the screw heads.
NOTICE:
Due to the abrasive nature of a pellet appliance fire, the
logs are not covered under warranty. Any placement variation other than shown here can cause excessive heat
and shall void the appliance warranty.
Figure 21.2
September 1, 2008
7036-135E
Page 21
R
Mt. Vernon Pellet Insert (AE)
H. Wall Control Thermostat Installation
1.
When mounting the wall control thermostat on the wall,
be sure to follow your wall control’s installation instructions carefully.
12 volt Power Inlet (for
optional battery back-up)
NOTE: The wall control thermostat should be
mounted on an inside wall and not in direct line
with the appliance convection air.
Houshold Power Inlet
NOTE: If the wall control thermostat is located too
close to the appliance, you may need to set the
temperature setting slightly higher to maintain the
desired temperature in your home.
2.
There is a 5 screw terminal block located on the back
lower left corner of the appliance directly above the
power cord inlet.
Green Wire
White Wire
Red Wire
Thermostat Wires in Center 3 Screws
The center 3 screws are for the wall control thermostat
wires and the 2 outer screws are mounting screw and
should not have wires attached to them.
The thermostat wires are color coded. The green wire
is on the top, the white in the middle and the red on the
bottom.
CAUTION
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
Figure 22.1
Page 22
7036-135E
September 1, 2008
R
8
Mt. Vernon Pellet Insert (AE)
Operating Instructions
2. Other Fuels
This appliance has been tested and approved by Hearth &
Home Technologies for shelled field corn, wheat and black
oil sunflower seeds.
CAUTION
Tested and approved for wood pellets, shelled field
corn, wheat and black oil sunflower seeds. Burning
of any other type of fuel voids your warranty.
When purchasing corn or wheat to burn in your appliance,
read the ingredient label very carefully. Do NOT purchase
fuel that contains any additives such as oils (i.e. soybean
oil) and meals as it will result in poor unit performance. If
you are buying corn or wheat the only ingredient that should
be listed is corn or wheat.
A. Fuel Size, Material and Storage
1. Wood Pellets
Wood pellets are made from sawdust or wood by-products. If
the source material is hardwood, they can have a higher mineral
content, creating more ash. Fuels containing bark will also have
higher ash content.
Shelled field corn must be 15% or less moisture content. The
corn must be clean and free from debris. Never burn corn
straight from the field. Stalk parts, excessive fines and cob
remnants, etc. will clog the auger mechanism. Corn with
excessive grain dust must be screened by sifting with 3/16
inch (4.76mm) mesh screening.
Minerals and other non-combustible materials such as sand
will turn into a hard, glass-like substance called a clinker when
heated to the extreme temperatures our firepot reaches. This
is what forms clinkers in the bottom of the firepot. Trees from
different areas will vary in mineral content. That is why some
fuels produce more clinkers than others.
Pellets are manufactured in either 1/4 inch or 5/16 inch (6-8mm)
diameter and should be no more than 1-1/2 inches (38mm)
in length. Pellet lengths may even vary by lot from the same
manufacturer which is why the feed rate may need to be adjusted
occasionally. If you burn pellets longer than 1-1/2 inches
(38mm) you may have an inconsistent fuel feed rate and/or
missed ignitions.
Pellet fuel quality can greatly fluctuate. The Advanced Energy
(AE) appliance has been designed to burn a wide variety of fuels,
giving you the choice to use the fuel that is most economical in
your region. Premium wood pellets have the lowest ash content,
under 1%. Standard grade pellet, high ash pellets, corn and
other biomass fuels all have higher ash content.
The higher the ash content, the more often the ash pan will need
to be emptied. Premium wood pellets will produce the least ash
and tends to produce the highest heat output.
Pellets made from hardwoods (i.e. oak) have a higher ash content
than pellets made from softwoods (i.e. pine). The hardwood
pellets may require more air to burn properly so make sure you
have the wall control on the correct setting.
If you are burning a higher ash fuel and your firepot and ash pan
are filling quickly, set the wall control on “Utility Pellet” and the
auto-clean system will empty the firepot more frequently.
Always burn dry fuel. Burning fuel with high moisture content
takes heat from the fuel and tends to cool the appliance,
robbing heat from your home. Damp pellet fuel can clog the
feed system.
We recommend that you buy fuel in multi-ton lots whenever
possible. However, we do recommend trying various brands
before purchasing multi-ton lots to ensure your satisfaction.
September 1, 2008
WARNING
Risk of Chemical Poisoning.
• Do Not burn treated seed corn
• Chemical pesticides are harmful or fatal if
swallowed
• Burning treated seed corn will void your
warranty
Do not burn treated seed corn in your appliance. Seed corn
is treated with chemical pesticides that are harmful or fatal if
swallowed; therefore, seed corn is dangerous to have in the
house, expecially where children can reach it. Burning treated
seed corn in your appliance will void your warranty and will
destroy the exhaust system on the unit.
When changing to a different fuel, be sure to empty the hopper
of the previous fuel and vacuum the hopper before you fill it
with the new fuel. Make the appropriate selection on the FUEL
SELECTION screen on the thermostat wall control. The burn
rate, BTU content and heat output will all vary depending on
fuel selected. See Figure 23.3 on page 23.
3. Storage
Wood pellets should be left in their original sealed bag until
using. This will prevent moisture absorption.
Shelled corn, wheat or sunflower seeds should be stored in
a tight container where it will not absorb moisture from damp
or wet floors. This will also prevent rodents from becoming
a problem.
Do not store any pellet fuel within the clearance requirements
or in an area that would hinder routine cleaning and
maintenance.
7036-135E
Page 23
R
Mt. Vernon Pellet Insert (AE)
B. General Operating Information
C. Before Your First Fire
See Wall Control Thermostat Manual
for detailed operating instructions.
1. First, make sure your appliance has been properly installed
and that all safety requirements have been met. Pay
particular attention to the fire protection, venting and wall
control thermostat installation instructions.
1. Wall Control Thermostat - Automatic Setting
2. Double check that the ash pan and firebox are empty and
then close the front door.
The appliance is like most modern furnaces; when the
wall control thermostat calls for heat, your appliance will
automatically light and deliver heat. When the room is up to
temperature and the wall control is satisfied the appliance
will shut down.
In the automatic setting the heat output level is controlled
by the wall control. Select “Automatic” on the AUTO/
MANUAL screen. Figure 24.1.
CAUTION
Tip of thermocouple must be in contact with the inside
end of the thermocouple cover
Missed ignitions can occur.
D. Starting Your First Fire
1. Fuel Selection
To start your first fire, you must select the appropriate fuel on
the FUEL SELECTION screen on the wall control to match the
fuel you have chosen to burn.
Automatic
Manual
Off
If the proper fuel is not selected your appliance will not operate
properly. For example, if you have selected wood pellets and
you are burning corn, the appliance may not light or may go out
or overfeed. Even if the correct fuel is already highlighted, press
“select” anyway to ensure proper initialization of the system.
Figure 24.3.
Figure 24.1
2. Wall Control Thermostat - Manual Setting
When you select “Manual” on the AUTO/MANUAL screen
the appliance will still automatically turn on and off
according to the temperature setting. However, you will
be able to manually control the heat output levels. Adjust
the heat output levels by using the HEAT OUTPUT LEVEL
screen.
2. Comfort Level Selection
Once your fuel is selected, select the temperature at the desired
setting on the SET COMFORT LEVEL screen. Figure 24.4.
3. Automatic or Manual Setting
The automatic setting will control the heat output based on
the comfort level selection. The manual setting allows you to
manually control the heat output settings. See Ignition Cycles
on page 25.
NOTE: See the Wall Control Thermostat manual for detailed
instructions.
Medium
FUEL SELECTION
Corn
Utility Pellet
Softwood Pellet
Sunflower Seeds
Wheat
Hardwood Pellet
Figure 24.2
3. Auto-Clean Firepot System
Your appliance is equipped with an automatic firepot
cleaning system that will change the frequency of cleaning
based on the fuel being burned.
DONE
SELECT
Figure 24.3
The auto-clean system will clean itself immediately on
initial plug in. If there is a power outage, as soon as power
is restored it will automatically clean itself.
Figure 24.4
Page 24
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
E. Fire Characteristics and Flame Height
Adjustment
G. Ignition Cycles
A properly adjusted fire with the heat output on HIGH has an
active flame pattern that extends out of the firepot approximately 8 inches (203mm).
If the fire has tall flames with black tails and seems somewhat lazy, the flame height will need to be reduced. If
the fire is not 8 inches (203mm) tall, the flame height will
need to be increased. A medium and low setting will give
a shorter flame.
The flame will rise and fall somewhat. This is normal.
With your appliance in Manual mode and the heat output
level set to High, adjust the flame height using the FLAME
HEIGHT ADJUST screen under USER SETTINGS on the
wall control. Figure 25.1.
The Advanced Energy engine is controlled by the digital wall
control. The digital display on the wall control will tell you
what your appliance is doing in the upper left corner, above
the line.
Every time the thermostat calls for heat, the appliance steps
through five cycles:
1.
2.
3.
4.
5.
Ignition cycle
Soft-start cycle
Heating cycle
Shut down cycle
Cleaning cycle
The duration and characteristics of these cycles may be different with each type of fuel selected.
1. Start-Up
During this cycle:
•
•
•
•
Figure 25.1
F. Battery Back-up System (Optional)
The appliance has been designed to operate on an optional
battery back-up system. If you have frequent power outages
in your region, hook the appliance up to a 12 volt battery and
it will automatically switch to battery power in the event of
power failure. There will be a battery icon that appears on
your wall control to let you know you are now operating on
battery power.
Once you are operating on battery power, you must manually
light the fire in the appliance as it will no longer automatically
light. Use only approved fire starting gel to start the fire. The
high burn rate is no longer available on battery back-up as
each level drops down one level. For example; the high burn
becomes medium high burn and so on.
We recommend a 12 volt deep cycle battery, (i.e., marine
or RV type). If the battery charge falls below 10 volt it can
no longer sustain the appliance operation and the appliance
will shut down. A 12 volt battery cable is available through
your local dealer.
CAUTION
• Hook up to battery terminals BEFORE you
plug battery into the appliance.
• Damage to internal electronic components
may occur.
September 1, 2008
The igniter turns on for 90 seconds to heat up the air
in the firepot
The combustion blower starts
Vacuum switch comes on
Feed motor turns on adding fuel to the firepot and
the appliance waits for the fire to start
The duration of start-up depends on the type and quality of
fuel used. It is normal to see some smoke during the ignition process as moisture evaporates and the fuel lights. The
smoke will stop once the fire starts.
If you are lighting your appliance for the first time the feed
tube is empty and it can take some time to fill it with fuel
before you will see a fire. To speed up this process, put a
handful of fuel in the firepot. You can also do this when you
have run your hopper dry.
2. SS-Low / SS-Med (Slow-Start Low, Slow-Start Medium)
Once the fire is lit, the appliance moves into the low soft-start
cycle as it continues to build the fire. In this cycle, more fuel
will be added. As the fire builds, the appliance will change to
medium soft-start mode and the heating cycle begins.
3. Auto / Man - L, ML, M, MH, H
There are two choices in the Automatic / Manual menu of
how your appliance will operate.
In Automatic Mode, the wall control will turn the heat output
level up or down depending on how far the room temperature is from the desired temperature. The digital display will
read AUTO:M as an example of automatic, medium level.
As the room temperature approaches the desired temperature, the appliance will turn down to lower settings. When
you change the appliance to Manual, set the heat output setting from the main screen. The right bottom button will read
HEAT OUTPUT.
7036-135E
Page 25
R
Mt. Vernon Pellet Insert (AE)
3. Auto / Man - L, ML, M, MH, H (Cont’d)
WARNING
You can operate the appliance from any of the 5 levels. On
the lowest level, the appliance will stay on longer, burn less
fuel per hour, but will take longer to bring the home up to
your desired temperature. On the highest setting, the appliance will burn more fuel per hour, but bring your home up to
temperature more quickly.
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot floor open.
Do NOT store fuel:
• Closer than required clearances to combustibles to appliance
• Within space required for loading or ash
removal.
Regardless of the heat output level, when the home reaches
your set temperature, the appliance will go into the shut
down cycle. In Manual mode heat output does not change.
Turn to OFF to stop operation.
4. Shutdown
Once your home has reached your set temperature, the
appliance will stop feeding fuel and allow the fire to diminish. The convection blower will continue to run until the
appliance cools to appropriate temperature and will go into
the auto-clean cycle.
WARNING
5. Auto Clean
The firepot auto-clean system will cycle when the appliance
is first plugged in:
•
• When the house reaches temperature and the appliance shuts down.
•
• At prescribed intervals, depending on the type of fuel
selected.
•
If your appliance is running and the auto-clean cycle is initiated, the appliance will revert to shut down cycle.
•
Fire Risk.
Keep combustible materials, gasoline
and other flammable vapors and liquids
clear of appliance.
Do NOT store flammable materials in the appliance’s
vicinity.
Do NOT use gasoline, lantern fuel, kerosene, charcoal
lighter fluid or similar liquids to start or “freshen up” a
fire in this heater.
Keep all such liquids well away from the heater while it
is in use.
Combustible materials may ignite.
The floor of the firepot will open and deposit the ash into the
ash pan. It takes approximately 2 minutes to complete the
auto-clean cycle. The floor will then shut, and if the thermostat is still calling for heat, the fire will start again, continuing
the heating process.
During this auto-clean cycle, the convection blower will continue to run.
Additional Screen Messages:
READY It is telling you that the home is up to temperature
and doesn’t need any heat.
- - - - - The screen will show 5 dashes when the wall
control and the control board are NOT communicating with
each other. Check that the wiring on the thermostat is properly connected.
MAINTENANCE BURN The maintenance burn is to keep
the system from shutting down when operating on battery
backup. The appliance will not automatically re-light in
manual mode.
OFF The AUTO/MANUAL SETTING screen has been set
to OFF. Set the appliance to OFF when performing periodic
maintenance to prevent an unexpected startup.
Page 26
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
H. Quick Start Guide
NOTICE: Any button pressed will turn on the backlight. Wall control will automati-
cally revert back to the starting screen if there is no activity for 15 seconds; except
for the “CONFIRM FUEL CHANGE” screen.
CHOOSING FUEL TYPE
:
R A
CHOOSING TEMP UNIT:
°F or °C
Buttons
M
:
R A
et at:
U
M
et at:
MENU
E
:
R A
U U
et at:
MENU
1.
M
At the starting screen, press “MENU”
button once or twice until “MENU”
screen appears.
MENU
Wall Control for Reference
M N
1.
At the starting screen, press “MENU”
button once or twice until “MENU”
screen appears.
TURNING ON APPLIANCE
et omfort Level
Auto Manual Off
:
R A
uel T pe
ser ettings
M
M N
et omfort Level
Auto Manual Off
et at:
uel T pe
2.
Highlight “FUEL TYPE” using the “UP/
DOWN” buttons to the right side of the
display. Press “SELECT”.
L
L
1.
ser ettings
4.
Now press “SELECT” to choose new
fuel
ON IRM
L
AN
lease empt hopper
of old fuel t pe and
ensure firebox is clean
lease refer to
section in manual
DONE
6.
7.
8.
confirm
fuel
2.
Highlight “USER SETTINGS” using the
“UP/DOWN” buttons to the right side of
the display. Press “SELECT”.
R
uel T pe
Scroll down and highlight “HARDWOOD PELLET” or your fuel type.
to
2.
et omfort Level
Auto Manual Off
3.
Press “DONE”
change.
At the starting screen, press “MENU”.
M N
TION
oftwood ellet
unflower eeds
Wheat
ardwood ellet
5.
ser ettings
MENU
TTIN
Temp nits
lame eight Adjust
Temp ifferential
Highlight “AUTO/MANUAL/OFF”.
Press “SELECT”.
A TO MAN AL
Automatic
Manual
Off
2.
Highlight “TEMP UNITS F/C” using the
“UP/DOWN” buttons to the right side of
the display. Press “SELECT”.
3.
Press the “UP” or “DOWN” button
to set desired temperature unit and
press “SELECT”..
4.
Press “DONE”. Press “DONE” again,
or wait 15 seconds for starting screen
to reappear.
TTIN
3.
Highlight “MANUAL”. Press “SELECT”.
4.
Press “DONE” twice or wait 15 seconds
for starting screen to reappear.
Press “DONE” twice or wait 15 seconds for starting screen to reappear.
Fill the hopper with fuel, and if the
hopper was completely empty, or has
run out of fuel, throw approximately
1/2 cup of pellets into the firepot.
Be sure the hopper lid and glass
door are both closed.
September 1, 2008
7036-135E
Page 27
R
Mt. Vernon Pellet Insert (AE)
H. Quick Start Guide (Cont’d)
SETTING COMFORT LEVEL
:
R A
SETTING HEAT OUTPUT
M
:
R A
MENU
1.
1.
Set temperature must be 3
degrees higher than room
temperature for appliance to
start.
Press “HOLD TEMP”.
T
OM ORT L
ON
ON
3.
MENU
U U
Press and hold “UP” or “DOWN” button to set desired temperature.
NOTE:
2.
E
M
et at:
old
et at:
E
U U
At the starting screen, press “HEAT
OUTPUT”.
Medium
igh
2.
Use the “UP” button to change “HEAT
OUTPUT LEVEL” to ”MEDIUM-HIGH”.
3.
Press “DONE” or wait 15 seconds for
starting screen to reappear.
L
OL
R
M
Press “DONE”.
Page 28
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
I. Frequently Asked Questions
ISSUES
SOLUTIONS
1. Metallic noise
1. Noise is caused by metal expanding and contracting as
it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not
affect the operation or longevity of your appliance.
2.
Ash buildup on glass
2. This is normal. Clean the glass.
3.
Glass has turned dirty
3. Excessive build up of ash. The lower burn settings will
produce more ash, the higher burn settings produce
less. The more it burns on low the more frequent cleaning of the glass is required.
4.
Fire has tall flames with black tails and is lazy
4. The flame height adjustment needs to be reduced or
the firepot needs cleaning. Heat exchanger or exhaust
blower needs cleaning.
5.
Excessive smokey start-up
5. Either the firepot is dirty or there is too much fuel at
start-up and not enough air.
6.
Large flame at start-up
6. This is normal. Flame will settle down once the fire is
established. Some smoke is normal.
7.
Mechanical Noise
7. The floor of the firepot in the auto-clean system may
make some noise as it scrapes the ash into the ash
pan.
CAUTION
Odors and vapors released during initial operation.
• Curing of high temperature paint.
• Open windows for air circulation.
Odors may be irritating to sensitive individuals.
September 1, 2008
7036-135E
Page 29
R
Mt. Vernon Pellet Insert (AE)
9
Troubleshooting
With proper installation, operation, and maintenance your appliance will provide years of
trouble-free service. If you do experience a problem, this troubleshooting guide will assist
a qualified service person in the diagnosis of a problem and the corrective action to be
taken. This troubleshooting guide can only be used by a qualified service technician.
Possible Cause
Error Message
Corrective Action
Bad wall control or control board
3 wires have loose connections or installed
wrong
Replace wall control or control board
Check connections
LOW BATTERY
Battery supply on battery backup is drained
Recharge battery
BAD TC DROP TUBE
Drop tube thermocouple is broken or leads are
reversed
Check connections
Check connections
TC = Thermocouple
Firepot thermocouple is broken or leads are
reversed
SNAP DISC TRIPPED
Overheat sensor (snap disc) has tripped
Unplug the appliance and then manually
reset snap disc
VACUUM SW ERROR
Vacuum switch is bad
Check connections. By-pass vacuum
with jumper wire, if run, switch is bad.
Replace switch
Vacuum hose is plugged/disconnected
Check vacuum hose
TC = Thermocouple
BAD TC FIREPOT
SW = Switch
COMB BLOWER JAMMED
Combustion blower is blocked/jammed
Replace thermocouple
Replace thermocouple
Remove blockage
Replace blower if necessary
Must unplug the appliance to clear error
AUGER JAMMED
Auger jammed, feed motor bad
Pull the feed system and inspect
Clear jam and then press Retry Button
MISSED IGNITION
Igniter bad or poor harness connection
Check connections, if OK replace igniter
Out of fuel or fuel is bridging in hopper
Break up bridging pellets
Refill hopper
Faulty firepot thermocouple, connection is
shorted
MIN FIREPOT TEMP
Out of fuel
Replace the thermocouple and then
press Retry
Refill hopper
Add handful of pellets to the firepot
Press the Retry button
MAX DROP TUBE TEMP
CONV BLOWER JAMMED
Wrong fuel table setting
Confirm setting matches burning fuel
Flame height set too high
Adjust flame height
Convection blower blocked/jammed
Remove blockage
Replace blower if necessary
Must unplug appliance to clear error
CHECK ASHPAN
SCREEN GOES BLANK
Auto-clean jammed
If ash pan is empty, check for a jam. Use
a screw driver and firmly push in the
firepot floor holes and flex spring and
push toward home to release jam.
Auto-clean switch is bad
Replace switch
Linkage has become disconnected
Reconnect linkage.
Hopper lid open while you refill hopper
Fill hopper between cycles
Switch is out of adjustment (auger will not
function)
Adjust or replace switch
Static discharge or nearby lightening or
Unplug the power to the appliance and
plug it back in
Electric Fast Transients at the input mains
Page 30
7036-135E
September 1, 2008
R
10
Mt. Vernon Pellet Insert (AE)
Maintaining & Servicing Your Appliance
A. Proper Shutdown Procedure
CAUTION
1. Set the wall control thermostat to “OFF” on AUTOMATIC/
MANUAL SETTING screen and let the appliance completely cool. Figure 31.1. The exhaust blower must be
off before you can unplug the appliance before servicing.
Shock and Smoke Hazard
• Proper Shutdown Procedure must be followed.
• Smoke spillage into room can occur if appliance
is not cool before unplugging.
2. Smoke spillage into the room can occur if the appliance
is not cool before unplugging.
• Risk of shock if appliance not unplugged before
servicing appliance.
3. There is a risk of shock if the appliance is not unplugged
before servicing the appliance.
Follow the detailed instructions found in
this section for each step listed in the chart
below.
Automatic
Manual
Off
Figure 31.1
B. Quick Reference Maintenance Chart
Cleaning or Inspection
Frequency
Daily Weekly Every 2 Monthly
Weeks
Yearly
Ash Pan - Burning Pellets
Every 5 bags of fuel
OR
Ash Pan - Burning Alternate Fuels
Every 1 bag of fuel
OR
X
Ash Removal from Firebox
More frequently depending on the
fuel type or ash build-up
OR
Auto-Clean Inspection
More frequently depending on the
fuel type
OR
Blower, Combustion (Exhaust)
More frequently depending on the
fuel type
OR
X
Blower, Convection
More frequently depending on the
fuel type
OR
X
Door Latch Inspection
Prior to heating season
OR
X
X
X
X
Firebox - Prepare for Non-Burn Season At end of heating season
OR
Firepot - Burning Pellets
OR
X
X
Every 3 bags
X
Firepot - Burning Alternate Fuels
Every 1 bag
OR
Glass
When clear view of firepot
becomes obscured
OR
Heat Exchanger & Drop Tube
Every 1 ton of fuel
OR
Hopper
Every 1 ton of fuel or when changing fuel types
OR
Top Vent Adapter
More frequently depending on the
fuel type or ash build-up
OR
X
Venting System
More frequently depending on the
fuel type
OR
X
September 1, 2008
7036-135E
X
X
X
Page 31
R
Mt. Vernon Pellet Insert (AE)
C. General Maintenance and Cleaning
3. Cleaning Ash Pan
•
1. Types of Fuel
Depending on the type of fuel you are burning will dictate how
often the firepot cleans itself. If the fuel you are burning has
a high dirt or ash content or you are burning other biomass
fuels, it may be necessary to do a more thorough cleaning
during the burn season.
•
Frequency:
Wood Pellet Fuel: Weekly or every 5 bags of fuel
Alternate Fuel: Daily
By: Homeowner
Locate the ash pan underneath the firepot. Slide the
ash pan straight out. Empty into a non-combustible
container and re-install ash pan. When replacing ash
pan push it back until it catches on the 2 side latches.
See Disposal of Ashes below.
The auto-clean firepot system will routinely clean the
firepot, at shutdown when the wall control is satisfied or the
predetermined amount of burn time has elapsed.
A clinker is formed when dirt, ash or a non-burnable
substance is heated to 2000°F (1093°C) and becomes glasslike. Clinkers filling the ash pan will have to be cleaned out
more often than ash. Excessive clinkers will eventually jam
the auto-clean system and generate an error. Figure 32.1.
4. Ash Removal from Firebox
•
•
Frequency: Weekly or more frequently depending on
fuel type or ash build-up.
By: Homeowner
There must not be any hot ashes in the firebox during
cleaning so allow the appliance to completely cool.
Frequent cleaning of the ash in the firebox with a vacuum
cleaner will help slow down the build-up of ash in the
exhaust blower and vent system.
WARNING
Disposal of Ashes
• Ashes should be placed in metal container
with tight fitting lid.
• Ashes should be retained in closed container
until all cinders have thoroughly cooled.
Clinker
Figure 32.1 - Large Clinker
2. Auto-Clean System Inspection
•
•
Frequency: Monthly or more frequently depending
on fuel type
By: Homeowner
5. Disposal of Ashes
•
•
Frequency: As needed
By: Homeowner
a. The appliance must be in complete shutdown,
completely cool and the exhaust blower off.
b. Inspect the auto-clean springs for any degradation or
deformation. As the springs heat up and cool down
they can lose tension.
If there is a gap showing above the firepot floor it means
the springs have lost their tension and can not keep
the floor in the proper position.
Ashes should be placed in a metal container with a
tight-fitting lid. The closed container of ashes should
be placed on a non-combustible floor or on the ground,
well away from all combustible materials, pending final
disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the
closed container until all cinders have been thoroughly
cooled.
This will cause ignition problems and fuel falling into
the ash pan. Replace them if that occurs.
c. Inspect the holes in the firepot floor for any debris.
They must be kept clear. If you are burning corn, the
holes have a tendency to fill with particles which will
need to be removed.
Page 32
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
d. A Micro Cleaning Kit can be purchased at your local
hardware store as an accessory for a shop vacuum.
Figure 33.2. Assemble the crevice tool. Figure 33.3.
6. Cleaning Firepot with Firepot Clean-Out Tool
•
Frequency:
Softwood Pellets: Weekly or every 5 bags
Hardwood Pellets: Weekly or every 3 bags
Alternate Pellets: Daily or every 1 bag
•
By: Homeowner
a. The appliance must be in complete shutdown,
completely cool and the exhaust blower off.
b. It may be necessary to use your firepot clean-out tool
to chip away material that has built up on the sides of
the firepot and to push out any clinkers. Larger clinkers
may have to be removed from the top of the firepot.
Corn clinkers can be especially difficult to break up. If
the clinker adheres to the sides of the firepot, you will
need to manually clean the firepot.
Figure 33.2
c. After cleaning the firepot and inspecting the holes,
turn off the power and then restore the power. The
auto-clean system will then clean itself.
d. The firepot floor plate must be fully closed when
finished.
Figure 33.3
7. Cleaning Heat Exchanger & Drop Tube
•
•
e. U se the crevice tool to finish cleaning the heat
Frequency: Monthly or every 1 ton of fuel
By: Homeowner
a. The appliance must be in complete shutdown,
completely cool and the exhaust blower off.
b. It is necessary to remove the baffle to gain access
to the heat exchanger. Follow instructions for baffle
removal on page 36.
c. Vacuum the ash from the heat exchanger with an
upholstery brush to remove the majority of the ash.
Be sure to vacuum the back of the baffle also. Inspect
the drop tube and remove any residue build-up in the
drop tube. Figure 33.1.
exchanger fins. It is critical that the 2 exhaust exists
at the back of the firebox floor (left and right) be
thoroughly cleaned. Figure 33.4. There are several
ways this can done.
1. Use the crevice tool.
2. Attach a hose 1/2 inch (12.7mm) in diameter and
approximately 2 feet (607mm) in length to your
vacuum hose.
3. Use a bottle brush and push the ash down to the
bottom. Remove the exhaust blower and then
vacuum out the ash. Figures 34.1-3 on page 34.
Figure 33.1
exhaust exits left and right side must
be thoroughl cleaned
ach exit is
approximatel
inches wide inch
across and inches deep
Figure 33.4
September 1, 2008
7036-135E
Page 33
R
Mt. Vernon Pellet Insert (AE)
f. Removing the Combustion (Exhaust) Blower
acuum out the exhaust area
1. The combustion blower is mounted in the bottom
right rear of the appliance. Figure 34.1.
2. Use an 11/32 nut driver to loosen all six nuts, but do
not remove. Rotate the blower and remove from the
housing. Figure 34.2.
3. Set the blower on the floor of the appliance. You do
not need to disconnect the wires.
4. Vacuum out the exhaust area. Figure 34.3.
Figure 34.3
Combustion Blower
Figure 34.1
Loosen all
nuts but do NOT Remove
Figure 34.2
Page 34
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
8. Cleaning the Hopper
•
•
10. Cleaning Exhaust Blower - Requires No
Lubrication
Frequency: Monthly, every 1 ton of fuel or when
changing fuel types.
By: Homeowner
•
•
•
After burning approximately 1 ton of fuel you will need
to clean the hopper to prevent sawdust and/or fines
build-up. A combination of sawdust/fines and pellets
on the auger reduces the amount of fuel supply to the
firepot. This can result in nuisance shut downs and
mis-starts.
a. The appliance must be in complete shutdown and
cool and the exhaust blower off.
b. Empty the hopper of any remaining pellets.
c.
9. Cleaning the Glass
•
•
11. Cleaning Convection Blower - Requires No
Lubrication
•
•
•
Frequency: When clear view of the firepot is obscured
By: Homeowner
Frequency: Yearly or as needed
By: Qualified Service Technician
Task: Contact your local dealer.
12. Door Latch Inspection
•
•
•
Vacuum the hopper and feed tube.
Frequency: Yearly or as needed
By: Qualified Service Technician
Task: Contact your local dealer.
Frequency: Prior to heating season
By: Homeowner
Task:
The door latch is non-adjustable but the gasketing between
the glass and firebox should be inspected periodically to
make sure there is a good seal. If the gasket is frayed or
damaged, replace with a new one.
a. Appliance must be completely cool before cleaning
glass.
b. Use a damp paper towel or any non-abrasive glass
cleaner. Wipe off with dry towel.
13. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
•
Frequency: Yearly or more frequently depending on
fuel type or ash build-up
By: Qualified Service Technician/Homeowner
•
CAUTION
The products of combustion will contain small particles
of fly ash. The fly ash will collect in the exhaust venting
system and restrict the flow of the flue gases.
Handle glass assembly with care.
At start-up if there is incomplete combustion, or if there
is a shutdown or incorrect operation of the appliance it
will lead to some soot formation. This will collect in the
exhaust venting system.
When cleaning glass door:
• Avoid striking, scratching or slamming
glass.
• Do NOT clean glass when hot.
The venting system may need to be cleaned at least
once a year or more often depending upon the quality
of your fuel or if there is a lot of horizontal pipe sections. Ash will build up more quickly in the horizontal
sections.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white film.
Refer to maintenance instructions.
14. Preparing Firebox for Non-Burn Season
•
•
WARNING
a.
The appliance must be in complete shutdown,
completely cool and the exhaust blower offf.
b.
Remove all ash from the firebox and vacuum thoroughly.
c.
Paint all exposed steel, including cast-iron. Use
the Touch-Up paint supplied with the appliance or
purchase paint from your local dealer. You must
use a high-temperature paint made specificially for
heating appliances.
7036-135E
Page 35
Handle glass doors with care.
• Inspect the gasket to ensure it is undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door
removed, cracked, broken or scratched.
September 1, 2008
Frequency: At the end of heating season
By: Homeowner
R
Mt. Vernon Pellet Insert (AE)
E. Baffle Removal
D. High Ash Fuel Content Maintenance
•
•
Frequency: As needed
By: Homeowner
WARNING
If the ash build-up exceeds the half way point in the firepot
before it automatically cleans, then the firepot is not being
cleaned often enough.
Another symptom is if clinkers are adhering to the sides
of the firepot. Double check the wall control to ensure the
proper setting has been selected for the fuel you are burning.
If that is correct, change the setting to “Utility Pellet”.
Cast iron is a very heavy material. The baffle is
made of cast iron and therefore is heavy and awkward at times to maneuver. Clear and prepare
your work area before you begin.
a. The appliance must be in complete shutdown, completely cool and the exhaust blower off.
b. Open door.
c. The baffle is located at the top inside of firebox.
WARNING
d. Remove baffle by placing a flat head screw driver into
the slot of the latches located in the upper corners and
push down. The bottom of the latch will fall forward off
of the post. Lift the baffle up and then out toward you.
Figure 36.2.
Fire and Smoke Risk.
•
•
High ash fuels or lack of maintenance
can cause firepot to overfill. Follow
proper shutdown procedure if ash buildup
exceeds half way point in firepot.
e. To replace the baffle, place the 2 locating ears behind
the bottom edge and tilt the baffle up and into place
Failure to do so could result in smoking,
sooting and possible hopper fires.
f. The baffle must be centered in the firebox before latching it in place. If it is not centered the latch is trapped
between the baffle and side of the firebox instead of
latching properly.
g. The bottom of the latches will fit over the posts. Push
the top of the latch forward to lock latch into place.
Firepot Overfills
Pellets Back Up
In Feed Tube
Baffle
Ash Build Up in Firebox
Figure 36.1
Latches
Insert flat head screw driver into “V”
section and push down and the bottom
of the latch will fall forward off of post
Locating ears - 1 on
each side. Fit behind
bottom edge.
Figure 36.2
Page 36
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
F. Glass Replacement
WARNING
• Glass is 5mm thick high temperature heat-resistant ceramic glass.
• DO NOT REPLACE with any other material.
• Alternate material may shatter and cause
injury
a. Swing open the face and remove door from the appliance by lifting door off of hinge pins and lay on a flat
surface face down.
b. Using a Phillips head screw driver, remove 4 screws 2
on the top and 2 on the bottom. Remove metal bracket
and then remove the glass. Figure 37.1
c. Replace with new glass with gasket.
d. Re-attached metal bracket with 4 screws.
e. Re-install door over hinge pins and close face.
Remove 4 screws
Metal Bracket
Glass with Gasket
Figure 37.1
September 1, 2008
7036-135E
Page 37
R
Mt. Vernon Pellet Insert (AE)
11
Reference Materials
A. Component Functions
1. Auto-Clean Motor
The auto-clean motor is located under and behind the
firepot on the left side, inside the convection air chamber.
It automatically opens and closes the firepot floor so ashes
can fall into the ash pan.
2. Auto-Clean Switch
The auto-clean switch is located on top of the auto-clean
motor. It communicates to the control board when the firepot
floor is open and when the auto-clean system has completed
its cycle and is back in the home (closed) position.
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF
THE APPLIANCE.
9. Firepot
The firepot is made of high quality ductile iron. The floor of
the firepot automatically opens for cleaning and is operated
by the auto-clean firepot system. The floor needs to return
to a completely closed position or the appliance will not
operate properly.
10. Fuses
This is an optional accessory. It will plug into the appliance
next to the power outlet located behind the left cast side
panel. An icon will display on the wall control when the
appliance has lost main power and is running on battery
back-up.
There are three fuses. Two fuses are located on the inside
of the control board. One fuse is AC and operates the
igniter and the other fuse is DC and operates all of the
other components. The third fuse is located in the power
supply. A fuse will blow should a short occur and shut off
power to the appliance. The fuses can only be serviced by
an authorized dealer.
4. Control Board
11. Heat Exchanger
The control board is located on the lower left side of appliance,
behind the left side panel and above the vacuum switch. It
controls the functioning of the appliance and communicates
with the wall control. The control board can only be opened
by an authorized dealer.
The heat exchanger is located behind the baffle and it
transfers heat from the exhaust system into the convection
air chamber. Remove the cast iron baffle to access the heat
exchanger.
5. Convection Blower
The hopper lid switch is located on the right side inside the
hopper. It senses whether the hopper lid is open and displays
an icon on the wall control and will turn off the feed motor.
3. 12 Volt Battery Back-Up Cable
The convection blower is mounted at the bottom left rear of
the appliance. The convection blower pushes heated air
through the heat exchange system into the room.
6. Door Switch
The door switch is mounted on the right side of the firebox
behind the door handle. It senses when the door is open
and will display an icon on the wall control, and will turn off
the auto-clean system and feed motor for safety.
7. Combustion (Exhaust) Blower
The combustion (exhaust) blower is mounted in the bottom
right rearof appliance. The blower is designed to pull the
exhaust from the appliance and push it out through the
venting system.
8. Feed System
The feed system is located on the right side of the appliance
and can be removed as an entire assembly. The assembly
includes the feed motor, mounting bracket, bearing and feed
spring (auger). The hollow feed spring (auger) pulls pellets
up the feed tube from the hopper area and drops them down
the feed chute into the firepot.
Page 38
12. Hopper Lid Switch
13. Igniter
The igniter is mounted on the base of the firepot. Combustion
air travels over the red hot igniter creating super heated air
that ignites the pellets.
14. Low Fuel Indicator
The low fuel indication is attached to the left side of the
hopper. It senses the amount of fuel in the hopper and will
display an icon on the wall control when the fuel level is
low.
15. Optical Switch (Auger)
The optical switch is located on top of the feed system and
communicates to the wall control that the auger is spinning
or it has stopped.
16. Power Receptacle
The power receptacle is located on the left side of the
appliance, behind the left cast side panel. Check the wall
receptacle for 120 volt, 60 Hz (standard current). Make sure
the outlet is grounded and has the correct polarity. A good
quality surge protector is highly recommended to protect
the electronics.
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
17. Power Supply
21. Vacuum Switch
The power supply is located at the bottom left side of the
appliance. It converts 120 volt AC current to 15 volt DC current
to power the appliance.
The vacuum switch is located on the right side of the
appliance under the feed motor behind the right side panel
and connects to the drop tube with a hose. This switch turns
the feed system on when vacuum is present in the firebox.
The vacuum switch is a safety device designed to shut off
the feed motor if the exhaust or the heat exchanger system
is dirty or plugged or if the firebox door is open.
18. Overheat Sensor (Snap Disc)
The overheat sensor is mounted on the back of the drop tube
in the center of the appliance and has a reset button. To
access it remove the right side panel. If the fire tries to burn
back into the feed system or push exhaust up the feed tube,
this sensor will shut the appliance down, however the wall
control will continue to display messages. This sensor must
be manually reset. Disconnect power before resetting.
19. Thermocouple - Firepot
The thermocouple is located on top of the firepot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control board
telling the control board there is a fire in the firepot.
22. Wall Control
The appliance is designed to run on a custom designed 3.3
volt DC thermostat wall control. It will not operate on any
other wall control. Refer to the instructions supplied with
the thermostat wall control.
23. Wiring Connections for Control Board
See Figure 39.1
24. Wiring Connection for Power Supply
See Figure 39.2.
20. Thermocouple on Drop Tube
The thermocouple is located on the bottom of the drop tube
on the right side and is attached with a wing nut. It turns
the convection blower on and off, varies the speed of the
convection blower and will shut down the appliance if internal
heat exceeds set temperature.
13 12
11 n/a 10 9
8
7
6
Fuse 15A 250V
(need to remove
cover)
5
4
3
Fuse 15A 120V,
under the cover
2
14
1
120V AC out to
Control Board
120V AC in
15
16
17
15V DC out to
Control Board
Figure 39.2
Fuse 15A 120V,
under the cover
Figure 39.1
#
Description
#
Description
#
Description
1
Combustion Blower
7
Thermostat Wall Control
11
Convection Blower (feedback)
2
Auto-Clean System
8
Combustion Blower (feedback)
12
Igniter
3
Feed/Auger Motors
9
Firepot Thermocouple
13
AC Power In for Igniter
4
Hopper/Door Switches
10
Drop Tube Thermocouple
14
Convection Blower Power
5
Auger/Auto Clean/Vacuum
Switches
n/a
Not Used
15
Overheat Sensor (Snap Disc)
11
Convection Blower (feedback)
16
DC Power In from Power Supply
6
Low Fuel
n/a
Not Used
17
12 Volt Battery Back-up
September 1, 2008
7036-135E
Page 39
R
Mt. Vernon Pellet Insert (AE)
B. Component Locations
Low Fuel
Indicator
Drop Tube
Door Switch
Control
Board
Convection
Blower
Exhaust Blower
Auger Optical Switch
behind Feed Motor
Feed
Motor
Vacuum
Switch
Power Supply
Figure 40.2 - Power Supply, Control Board, Convection Blower
Re-set
Button
Heat Exchanger,
Front & Back
Overheat
Sensor
Baffle
Wing Nut - Securing
Overheat Sensor in
place.
Figure 40.1 - Feed Motor, Vacuum Switch, Exhaust
Blower, Overheat Sensor
Ash Pan
Firepot
Thermocouple and
Thermocouple Cover
Figure 40.3 - Heat Exchanger, Baffle, Ash Pan,
Firepot Thermocouple & Thermocouple Cover
Page 40
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
C. Exploded Views
Item
Description
Part Number
1
Door Frame Assembly
7034-026
2
Latch Assembly, Door
7034-039
3
Glass Assembly
7034-007
4
Glass Retainer
7034-136
5
Hinge, Female
450-2910
6
Magnet & Bracket Assembly
7034-008
7
Door Air Deflector
7034-185
Glass Size: 21 in. w x 14 in. h.
Figure 41.1 - Door, Glass & Door Latch Assembly
Item
17
Auto-Clean Motor Arm Assembled
18
19
22
20
16
21
23
25
24
26
27
15
28
29
30
14
31
13
32
12
10
11
Figure 41.2 - Firepot, Igniter & Auto-Clean Systems
September 1, 2008
Description
Part Number
10
Auto-Clean Link Arm
7034-176
11
Auto-Clean Plow
7034-024
12
Auto-Clean Rail
SRV7034-152
13
Spring, Qty: 4
7000-299/4
14
Clip, Hitch Pin 3/32, Qty: 10
7000-374/10
15
Firepot Bottom
7034-153
16
Heating Element, 18” (Igniter)
SRV7000-226
17
Thermocouple
SRV7000-334
18
Clip, Half
7000-321
19
Thermocouple Cover
SRV7034-186
20
Firepot Assembly
SRV7034-010
21
Gasket, Firepot
7034-190
22
Auto-Clean Motor/Arm Assy
7034-020
23
Auto-Clean Lever
7034-158
24
Gasket, Auto-Clean
7034-165
25
Auto-Clean Motor Arm Mount
not sold sep.
26
Bearing
7000-333
27
Crank Arm
not sold sep.
28
Spacer
not sold sep.
29
Auto-Clean Cam, Switch
SRV7034-187
30
Switch, Micro, Normally Open
7000-327
31
Motor 12 Volt
7000-300
32
Auto-Clean Motor Grommet
7034-188
7036-135E
Page 41
R
Mt. Vernon Pellet Insert (AE)
Figure 42.1
#
Description
#
Description
#
Description
35
Front, Lower
49
Detent Pin 3/16
64
Elbow Catch
36
Door, Cast, Right
50
Blower, Convection
65
Clip, Catch
37
Front, Upper
51
Exhaust Transition & Flue Collar
66
Side, Cast (left & right)
38
Door Assembly
53
Sensor, Overheat (Snap Disc #3)
67
Side Window Backer
39
Ash Pan
54
Feed Motor, DC Current
68
Glass, Side, with Gasket
40
Gasket, Ash Door
55
Switch, Optical Assembly
69
Gasket, (Rope), Door
41
Bottom Base
56
Bracket, Feed Motor
70
Hinge, Male, Door
42
Bracket, Latch Assembly
57
Gasket, Feed Motor
71
Baffle
43
Switch, Magnetic
58
Feed Spring Only
72
Latch, Baffle
44
Vacuum Switch
59
Bracket, Hopper Magnet
73
Hinge Pin Retainer, Front
45
Power Supply Assembly
60
Hinge Assembly, Top
74
Hinge Pin, Front
46
Blower, Combustion
61
Hopper Lid
75
Door, Cast, Left
47
Control Board
62
Top, Cast
76
Clip, Receiver
48
Gasket, Blower, Convection
63
Bracket, Catch
77
Ash Pan Door
78
Intake Shield
Page 42
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
D. Service Parts and Accessories
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on the
Quadra-Fire web site at www.quadrafire.com. When ordering, supply serial number and model to
ensure correct service parts.
Item No.
Accessories
Part No.
12 Volt Power Cord for Battery Back-up
12VCORD-AE
Firescreen
SCR-7005
Hearth Support
ZCSPT-MVI
Log Set, 2 pieces
LOGS-60-AE
Outside Air Kit
OAK-3
Surround, Standard Panel, 46-1/8” wide x 34-7/8” high, requires Cast Trim
SP-MTVS-CST
Surround & Gold Trim Set, Standard Panel 50” wide x 33” high
SP-MTVS-GD
Surround & Black Nickel Trim Set, Standard Panel 50” wide x 33” high
SP-MTVS-NB
Trim Cast Set, Cast, Matte Black
811-0930
Trim Cast Set, Powder Coat, Sienna Bronze
TR-CAST-CSB
Trim Cast Set, Powder Coat, Willow
TR-CAST-CWL
Trim Cast Set, Porcelain, Mahogany
811-0960
Item No.
Service Parts
Part No.
39
Ash Pan Assembly
7034-013
77
Ash Pan Door
7034-133
Auto-Clean Bottom Assembly
7034-021
23
Auto-Clean Lever
7034-158
10
Auto-Clean Link Arm
7034-176
22
Auto-Clean Motor/Arm Assembly
7034-020
32
Auto-Clean Motor Grommet
7034-188
11
Auto-Clean Plow
7034-024
12
Auto-Clean Rail
SRV7034-152
29
Auto-Clean Cam, Switch
SRV7034-187
71
Baffle
SRV7034-148
26
Bearing for Auto-Clean System, Qty: 1
7000-333
46
Blower, Combustion (Exhaust) with Gasket
7034-033
50
Blower, Convection
SRV7000-260
41
Bottom Base, Matte Black
7036-109MBK
41
Bottom Base, Porcelain Mahogany
7036-109PMH
41
Bottom Base, Powder Coat, Sienna Bronze
7036-109CSB
41
Bottom Base, Powder Coat, Willow
7036-109CWL
63
Bracket, Catch
7036-145
Bracket, Control Board
7034-212
Bracket, Door Switch
7034-215
56
Bracket, Feed Motor
7034-143
59
Bracket, Hopper Magnet
7036-149
Bracket, Hopper Switch
7036-148
September 1, 2008
7036-135E
Page 43
R
Mt. Vernon Pellet Insert (AE)
Item No.
42
Service Parts
Part No.
Bracket, Latch Assembly
7034-014
Bracket, Overheat Sensor (Snap Disc)
7034-150
Bracket, Vacuum Switch
7034-211
65
Clip, Catch
7036-146
18
Clip, Half, Holds Thermocouple in Place in the Firepot
7000-321
14
Clip, Hitch Pin 3/32, for Auto-Clean System, Qty: 10
7000-374/10
76
Clip, Receiver, Black
704-832
Clip, Wire, Qty: 10
7000-400/10
Component Pack, Mahogany (includes owner’s manual, warranty card, quick start
guide, heat exchanger and exhaust cleaning instructions, DVD “How To”, wall control
& harness, power cord, (4) leveling nuts & bolts, firepot clean-out tool, touch-up paint
and label “If Fireplace Altered”)
7036-021
Component Pack, Matte Black (includes same as above)
7036-018
Component Pack, Sienna Bronze, (includes same as above)
7036-019
Component Pack, Willow, (includes same as above)
7036-020
47
Control Board
SRV7000-456
49
Detent Pin 3/16 for Convection Blower
7000-376
38
Door Assembly
7034-006
1
Door Frame Assembly
7034-026
7
Door, Air Deflector
7034-185
75
Door, Left, Matte Black
7005-110MBK
75
Door, Left, Porcelain Mahogany
7005-110PMH
75
Door, Left, Powder Coat, Sienna Bronze
7005-110CSB
75
Door, Left, Powder Coat, Willow
7005-110CWL
36
Door, Right, Matte Black
7005-109MBK
36
Door, Right, Porcelain Mahogany
7005-109PMH
36
Door, Right, Powder Coat, Sienna Bronze
7005-109CSB
36
Door, Right, Powder Coat, Willow
7005-109CWL
64
Elbow Catch
7000-393
51
Exhaust Transition & Flue Collar Assembly
SRV7036-029
Face Plate
7034-124
54
Feed Motor, DC Current
SRV7000-313
Feed Motor & Spring Assembly
7034-004
58
Feed Spring Only
SRV7001-046
20
Firepot Assembly
SRV7034-010
15
Firepot Bottom
7034-153
Firepot Clean-Out Tool
414-1140
Firepot Riser Clamp Assembly
7034-012
Firepot Riser Assembly
SRV7034-002
35
Front, Lower, Matte Black
7036-122MBK
35
Front, Lower, Porcelain, Mahogany
7036-122PMH
35
Front, Lower, Powder Coat, Sienna Bronze
7036-122CSB
35
Front, Lower, Powder Coat, Willow
7036-122CWL
37
Front, Upper, Lower, Matte Black
7036-105MBK
37
Front, Upper, Powder Coat, Sienna Bronze
7036-105CSB
Page 44
7036-135E
September 1, 2008
R
Item No.
Mt. Vernon Pellet Insert (AE)
Service Parts
Part No.
37
Front, Upper, Powder Coat, Willow
7036-105CWL
37
Front,Upper, Porcelain, Mahogany
7036-105PMH
40
Gasket, (Rope), Ash Door
SRV7034-178
69
Gasket, (Rope), Door
SRV7034-177
24
Gasket, Auto-Clean
7034-165
48
Gasket, Blower, Convection
7000-329
Gasket, Blower, Combustion, between housing & appliance
SRV7000-332
Gasket, Blower, Combustion, between housing and motor
SRV7000-423
Gasket, Exhaust
7034-109
Gasket, Extruded Edge, 10 ft
7000-319/10
Gasket, Extruded, 10 ft
7000-320/10
57
Gasket, Feed Motor
7034-144
21
Gasket, Firepot
7034-190
Gasket, Glass, 1/8” x 1-1/4”, 10 ft.
7000-377/10
3
Glass Assembly for Door
7034-007
4
Glass Retainer
7034-136
68
Glass, Side, Assembly, Qty: 1
414-5380
16
Heating Element, 18” (Igniter)
SRV7000-226
16
Heating Element, 18” (Igniter), Qty: 10
7000-462/10
60
Hinge Assembly, Top
7036-006
5
Hinge, Female, Door
450-2910
70
Hinge, Male, Door
7034-138
73
Hinge Pin Retainer, Front, Door
7036-112
74
Hinge Pin, Front, 4 inches, Door
7036-110
61
Hopper Lid, Matte Black
7036-107MBK
61
Hopper Lid, Porcelain, Mahogany
7036-107PMH
61
Hopper Lid, Powder Coat, Sienna Bronze
7036-107CSB
61
Hopper Lid, Powder Coat, Willow
7036-107CWL
78
Intake Shield
7034-224
72
Latch, Baffle
7034-149
2
Latch, Door Assembly
7034-039
Log, Front, Left
7034-227
Log, Front, Right
7034-226
Magnet, Round
SRV7000-140
6
Magnet & Bracket Assembly
7034-008
31
Motor, Gear, 12V, Auto-Clean
7000-300
Nut, Push, 5/16 (Speed Nut), holds glass to castings, Qty: 24
7000-422/24
Paint, Touch-Up, Matte Black
7000-304
Paint, Touch-Up, Porcelain Mahogany
855-1450
Paint, Touch-Up, Powder Coat, Sienna Bronze
TOUCHUP-CSB
Paint, Touch-Up, Powder Coat, Willow
TOUCHUP-CWL
Paint, 1 12 oz. can, Sienna Bronze
PAINT1-CSB/CES
Paint, 1 12 oz. can, Willow
PAINT1-CWL/CTO
Power Cord
812-1180
Power Supply Assembly
SRV7000-324
45
September 1, 2008
7036-135E
Page 45
R
Mt. Vernon Pellet Insert (AE)
Item No.
Service Parts
Part No.
Rivet, Button Head, Gold
Qty 1: 72171
Qty 2: 844-5750
Rivnut Repair Kit, 1/4-20
RIVNUT-REPAIR
Screw 1/4-20 x 3/8”, Qty: 24
7000-401/24
Screw 1/4-20 x 5/8”, Qty: 24
7000-398/24
Sensor, Overheat (Snap Disc #3, Manual Re-set))
230-1290
Sensor, Fuel Level
7000-380
67
Side Window Backer
414-0280
66
Side, Matte Black (left & right are interchangeable)
7036-103MBK
66
Side, Porcelain, Mahogany, (left & right are interchangeable)
7036-103PMH
66
Side, Powder Coat, Sienna Bronze, (left & right are interchangeable)
7036-103CSB
66
Side, Powder Coat, Willow, (left & right are interchangeable)
7036-103CWL
13
Spring, Auto-Clean, Qty: 4
7000-299/4
43
Switch, Magnetic
7000-375
30
Switch, Micro, Normally Open
7000-327
55
Switch, Optical Assembly
7034-038
17
Thermocouple, Firepot
SRV7000-334
19
Thermocouple Cover
SRV7034-186
53
Thermocouple Ring Mount
SRV7000-381
Thermostat Wire, 3 Conductor
7000-409
62
Top, Matte Black
7036-101MBK
62
Top, Porcelain, Mahogany
7036-101PMH
62
Top, Powder Coat, Sienna Bronze
7036-101CSB
62
Top, Powder Coat, Willow
7036-101CWL
Top Mount, Left
SRV7036-117
Top Mount, Right
SRV7036-115
Vacuum Hose
7000-373
Vacuum Switch
SRV7000-166
Wall Control, Thermostat, Programmable
SRV7000-451
Wire Harness, Auger, Auto Clean, Vacuum Switch
SRV7034-191
Wire Harness, Battery Back-up
7034-202
Wire Harness, Convection Blower
7034-219
Wire Harness, Door, Hopper
SRV7034-192
Wire Harness, Igniter (Heating Element)
SRV7034-199
Wire Harness, Overheat Sensor
7034-193
Wire Harness, Power Out, AC Current
7034-220
Wire Harness, Power Out, DC Current
7034-221
Wire Harness, Power (Supply) Receptacle
SRV7034-233
Wire Harness, Thermostat
SRV7034-200
44
Item No.
Page 46
Appliance
Part No.
Mt. Vernon Insert, Advanced Energy (AE), Matte Black
MTVERNINSAE-MBK
Mt. Vernon Insert, Advanced Energy (AE), Powder Coat, Sienna Bronze
MTVERNINSAE-CSB
Mt. Vernon Insert, Advanced Energy (AE), Powder Coat, Willow
MTVERNINSAE-CWL
Mt. Vernon Insert, Advanced Energy (AE), Porcelain, Mahogany
MTVERNINSAE-PMH
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
E. Service And Maintenance Log
Date of Service
September 1, 2008
Performed By
Description of Service
7036-135E
Page 47
R
Mt. Vernon Pellet Insert (AE)
E. Service And Maintenance Log (Cont’d)
Date of Service
Page 48
Performed By
Description of Service
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
F. Homeowner’s Notes
September 1, 2008
7036-135E
Page 49
R
Mt. Vernon Pellet Insert (AE)
G. Warranty Policy
Hearth & Home Technologies LIMITED WARRANTY
Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood,
pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or
Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
Warranty Period
Parts
Labor
1 Year
2 years
Gas
X
X
HHT Manufactured Appliances and Venting
EPA
Wood
Pellet
Electric
Wood
X
X
X
X
X
X
X
X
X
Venting
Components Covered
X
All Parts and Material Except
as covered by Conditions,
Exclusion, and Limitations
listed
Igniters, Electronic Components, and Glass
Blowers
X
3 years
X
5 years
3 years
7 years
3 years
10
years
1 year
X
1 year
X
Limited
Lifetime
90 Days
Molded Refractory Panels
X
Firepots
X
X
Castings & Baffles
X
X
Firebox, HHT Chimney, Termination & Heat Exchanger
Burners, Logs & Refractory
Firebox & Heat Exchanger
X
X
X
X
X
See Conditions, Exclusions, and limitations.
X
All Replacement Parts
9-01-08
CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY
This warranty applies to the original owner and is transferable up to two years from date of purchase to the new
homeowner, provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance
remains in its original place of installation.
The maximum amount recoverable under this warranty is limited to the purchase price of the product.
In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.
Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the
home is not covered under this warranty.
This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing,
glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or
corrosion on any of the metal surfaces, cast iron components, baffles, firepots, doors, or firebox area are not covered by this warranty.
Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to
this noise are not covered by this warranty.
4021-645A 09-01-08
Page 50
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
Hearth & Home Technologies LIMITED WARRANTY (Cont’d)
HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance of the appliance not in accordance with the installation instructions; operating instructions and the listing
agent identification label furnished with the appliance; (2) installation which does not comply with local building codes;
(3) shipping, improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure or handling
devices such as exhaust fans or forced air furnaces or other such causes; (5) use of fuels other than those specified
in the operating instructions; (6) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; and/or (7) modification of the appliance not expressly authorized and approved by HHT in writing.
This warranty does not apply to non-HHT venting components, hearth components or other accessories used in conjunction with the installation of this product.
This warranty is void if the appliance has been over-fired or operated in atmospheres contaminated by chlorine,
fluorine, or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or
there is any damage to the appliance or other components due to water or weather damage which is the result of, but
not limited to, improper chimney or venting installation.
HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship
during the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the
defective component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.
Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not
apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state.
EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE
WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF
THE WARRANTY SPECIFIED ABOVE.
This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all warranties currently in existence.
If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier.
4021-645A 09-01-08
September 1, 2008
7036-135E
Page 51
R
CONTACT INFORMATION:
Hearth & Home Technologies
1445 North Highway
Colville, WA 99114
Division of HNI INDUSTRIES
Please contact your Quadra-Fire dealer with any questions or concerns.
For the number of your nearest Quadra-Fire dealer
visit our web site at www.quadrafire.com
NOTICE
• Leave this manual with
party responsible for use
and operation.
T
O
N RD
O A
D SC
I
D
DO NOT DISCARD THIS MANUAL
• Important operating and • Read, understand and
follow these instrucmaintenance instructions for safe installations included.
tion and operation.
We recommend that you record the following pertinent
information for your MT. VERNON PELLET INSERT (AE)
Date purchased/installed:
Serial Number:
Location on appliance:
Dealership purchased from:
Dealer phone:
Notes:
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534,
5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407,
5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099,
6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579,
6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064,
6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408,
2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.