Technology HYDROSONIC 2000 Std & SV INSTRUCTION MANUAL VERSION 1.2

Technology HYDROSONIC 2000 Std & SV INSTRUCTION MANUAL VERSION 1.2
HYDROSONIC 2000 Std & SV INSTRUCTION MANUAL
VERSION 1.2
VALID FOR SOFTWARE VERSION’S
up to V 1.4
Technology
A Translucent, Optically Reflective Haze
PLEASE READ THESE INSTRUCTIONS CAREFULLY
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
CONTENTS
INDEX.......................................................................................................................................................PAGE 1
INTRODUCTION......................................................................................................................................PAGE 2
TRANSFORMER SETTINGS...................................................................................................................PAGE 3
TIPS & SAFETY.........................................................................................................................................PAGE 4
SPECIFICATIONS.....................................................................................................................................PAGE 5
GETTING STARTED..........................................................................(CONNECTING THE FLUID)....PAGE 6
...............................................................................................(WHICH FLUID)....PAGE 6
OPERATING THE HYDROSONIC....................................................(USING THE CONTROLLER)....PAGE 7
...........................................................................(TURNING OFF)....PAGE 8
DMX 512.....................................................................................................................................................PAGE 9
MARTIN PROTOCOL..............................................................................................................................PAGE 10
MACHINE LAYOUT...................................................................................................(REAR PANEL)...PAGE 11
.....................................................................................................(CONTROLER)...PAGE 11
.....................................................................................................(PCB LAYOUT)...PAGE 12
SERVICE AND MAINTENANCE......................................................................(ERROR MESAGES)...PAGE 13
...................................................................(CHANGING A FUSE)...PAGE 14
.......................................(REPLACING A POWER AMPLIFIER)...PAGE 15
...............................................................(TROUBLE SHOOTING)...PAGE 16
ADDITIONAL INFORMATION..........................................................(ADDRESS & TELEPHONE)....PAGE 17
PAGE 1
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
INTRODUCTION
Thank you for buying the HYDROSONIC 2000 haze generator. Please take some time to read this instruction
manual carefully. The HYDROSONIC 2000 is a revolutionary machine that will enhance your lighting with out
the distracting clouds of smoke as with traditional smoke machines. There are no noisy compressors or heaters,
just a light haze that will enhance your lighting. The HYDROSONIC also uses much lower concentrates than
standard smoke machines or cracked oil machines, so there are no oily deposits left on expensive lighting
equipment or on floors and surfaces. Once you use the HYDROSONIC you will never go back.
The HYDROSONIC 2000 is a different breed of haze generators. JEM have developed a revolutionary way of
generating a reflective haze. There is a main tank inside the HYDROSONIC that contains ceramic devices called
transducers. These transducers are the basis of the effect, the transducers oscillate at high frequency's, this causes a
jet to be produced. From this jet are varying sizes of particles some of which are small enough to be filtered out and
blown into the atmosphere, the larger particles remain inside the main tank and fall back into the reservoir of fluid.
This reservoir of fluid in the main tank is a critical and if this is to high or to low the output will deteriorate.
Because of this there are to level detectors ensuring the correct level at all times. If the machine is on an incline or
uneven surface this fluid level indicators will give false readings and may shut down the machine.
The output from the HYDROSONIC is boosted via a tangential fan This can direct the smoke to where you want it
on low output the effect will be dispersed low (around 3 metres high) and at full out put the effect will be dispersed
up to five times higher. There is also a feature called AUTO, this will vary the output
FEATURES
Virtually silent operation
Low concentrates of chemicals
Intelligent onboard controller
Variable output
Fluid evacuation system
Timed operation or continuous
DMX 512 controllable (uses two channels)
Martin protocol controllable
No warm up time
Low maintenance
No oily deposits
! NOTE
JEM SMOKE MACHINE CO. LTD.
Reserve the right to make changes or
modifications regarding the HYDROSONIC 2000.
No part of this manual may be copied without permission.
PAGE 2
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
FIRST STEPS
NOTE! ALWAYS CHECK THAT THE HYDROSONIC IS DISCONNECTED FROM
THE MAINS BEFORE CHANGING TRANSFORMER SETTINGS.
CHANGING THE MAINS SUPPLY SETTINGS
The HYDROSONIC 2000 is able to operate on the three standard mains voltages, 240v, 230v, and 110v. The only
modification is to the mains transformer wiring. The HYDROSONIC has a factory setting voltage, this is recorded
on the serial label situated on the rear panel. If the HYDROSONIC is setup for the U.K. but is now outside the U.K.
the transformer wiring must be modified. Remove the three screws holding the transformer access pane and check
that the BROWN wire is in the correct position according to the diagrams below.
TRANSFORMER ACCESS PANEL
4
3
2
1
240V setting-brown wire to number 4
4
4
3
3
2
2
1
1
230V setting-brown wire to number 3
110V setting-brown wire to number 2
PAGE 3
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
TIPS AND SAFETY
ALWAYS CONNECT TO THE CORRECT MAINS POWER SUPPLY
ALWAYS USE GENUINE JEM HYDROSONIC FLUID
ALWAYS DISCONNECT FROM THE MAINS BEFORE ATTEMPTING ANY WORK ON THE HYDROSONIC
ALWAYS RUN THE HYDROSONIC ON A LEVEL FLOOR
OPERATE THE TANK EVACUATION SYSTEM ON A REGULAR BASIS
NEVER ATTEMPT TO DO ANY WORK ON THE HYDROSONIC THAT IS NOT DESCRIBED IN THIS MANUAL
DO NOT START THE TANK EVACUATION IF THERE IS MORE THAN 6.50 LITRES IN THE CONTAINER
NEVER POUR FLUID DOWN THE OUTPUT NOZZLE
READ THIS INSTRUCTION MANUAL FULLY BEFORE OPERATING THE HYDROSONIC
DO NOT TIP THE MACHINE UPSIDE DOWN
ENSURE THE CORRECT FUSES ARE FITTED WHEN REPLACING THEM
DO NOT BLOCK THE AIRFLOW VENTS AT THE REAR OF THE MACHINE
ALWAYS USE THE ORIGINAL PACKING WHEN TRANSPORTING THE HYDROSONIC
CONSULT YOUR SUPPLIER FOR ADVICE ON THE CORRECT FLUID TO USE
CONNECTING THE MAINS PLUG
BROWN WIRE..............................LIVE (L)
BLUE WIRE..................................NEUTRAL (N)
GREEN/YELLOW WIRE.............EARTH (E)
NOTE! THIS APPLIANCE MUST BE EARTHED
PAGE 4
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
SPECIFICATIONS
DIMENSIONS
L= 897mm
ELECTRIC'S
POWER SUPPLY..................................................... 240 volts AC
.................................................... 230 volts AC
.................................................... 110/120 volts AC
POWER CONSUMPTION...................................... @ 230 / 240 volts - 400 watts
...................................... @ 110 / 120 volts - 400 watts
MAINS CONNECTOR..............................................3 pin female I.E.C
DMX 512 CONNECTORS.......................................DMX IN:- 5 pin male XLR
.......................................DMX OUT:- 5 pin female XLR
MARTIN PROTOCOL CONNECTORS..................IN:- 3 pin male XLR
...................OUT:- 3 pin female XLR
FLUID
CONTAINER............................................................9.50 LITRES
.............................................................2.09 IMP GALLONS
.............................................................2.50 U.S. GALLONS
FLUID TYPES..........................................................STANDARD
..........................................................LONG LASTING
FLUID CONSUMPTION.........................................2.10 Lt. per hour (average)
2.50 Lt. per hour (max )
PAGE 5
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
GETTING STARTED
Fixed to machine
Fluid pipe
JEM HYDROSONIC
FLUID
5%
Technology
10%
ATransluscent,OpticallyReflectiveHaze
CAUTION
NOTFORHUMANCONSUMPTION.KEEPOUTOFTHEREACHOFCHILDREN.ALWAYSUSEINAWELL
VENTILATEDAREA.IFSPILTONFLOORING,CARPET,CLOTHESORHANDSWASHTHOROUGHLYWITH
WATER.FOGEFFECTSINCERTAININSTANCES,MAYCAUSEDISCOMFORTTOPERSONSSUFFERING
FROMRESPIRATORYANDALLERGICCONDITIONS.
JEMSMOKEMACHINECO.LTD. VALEROADINDEST,BOSTONROAD, SPILSBY,LINCS,PE235HE.ENGLAND
TEL:+(44)01790754050
FAX:+(44)01790754051
Fluid container
CONNECTING THE FLUID
Before operating the HYDROSONIC 2000 you must connect some fluid Check you have the correct
fluid type, remove the cap that is on the new container, now fit the container in to the compartment and
screw on the container cap that is fixed to the machine. Check that the pipe is connected properly and
that the container cap is secure. Do not loose the cap that is fixed to the machine you will not be able to
operate the HYDROSONIC without it. Note care must be taken not to spill fluid over the machine.
Note: The fluid container must be fitted at all times during operation.
FLUID TYPES
There are two types of JEM HYDROSONIC FLUID "STANDARD" & "LONG LASTING".
They are both suitable for use in the HYDROSONIC 2000 and have slightly different uses.
STANDARD is a low concentrate suitable for most applications where there is not a high
ambient (room temperature). This will give a light haze and will last a good while.
LONG LASTING has a slightly higher concentrate and will last longer than the STANDARD
fluid in higher ambient. JEM recommends using the LONG LASTING fluid in ambient above
25 degrees Celsius.
If you require more advice on the correct fluid to use please contact the supplier of your machine
or contact JEM direct.
NOTE! USING NON GENUINE FLUID MAY DAMAGE YOUR MACHINE AND WILL
INVALIDATE THE JEM WARRANTY.
JEM SMOKE PLC.
PAGE 6
HYDROSONIC 2000 INSTRUCTION MANUAL
OPERATING THE HYDROSONIC 2000
USING THE CONTROLLER
The HYDROSONIC 2000 has a comprehensive onboard controller that controls all the functions of the
HYDROSONIC. The controller can remember the previous settings used, so there is no need to set the
output levels and serial communication settings every time you turn the HYDROSONIC on. The controller
has four buttons that access and set the various options. Please look at the diagram below to see the layout of
the functions..
When you first turn on the HYDROSONIC the controller runs through a sequence and displays the software
version number and checks for errors. After this sequence OFF is displayed and the machine is ready to be
operated. You should then connect a container of JEM HYDROSONIC FLUID to the fluid pipe ensuring a
tight fit. You should then depress the ENTER button on the control panel, FILL should now be displayed
(if the main tank had not been emptied the last time the machine was used FILL will only be displayed for a
short time) the main tank takes approximately two minites to fill to the correct level. ON is now displayed on
the controller, you can now set the output levels required. Depress the MENU button RUN is displayed, then
using the (+) and (-) buttons select OUTP on the display panel (this is the output menu) you then depress
ENTER, FAN or TRAN will be displayed FAN is the main fan that throws the effect out of the front of the
machine this can be set from 20% to 100% and also has an AUTO setting that varies the output from 20% to
100% automaticly. When FAN is displayed depress enter and the current level is shown, to change the level
use the (+) and (-) buttons until the desired level is displayed. Once sellected depress ENTER and FAN
will be displayed, to set the output level of the effect depress the (+) button and TRAN will be displayed. As
before depress ENTER and select the output level using the (+) and (-) buttons, once the level is set depress
ENTER. Now the machine is ready to operate, depress the MENU button until RUN is displayed and then
depress ENTER. You can now set the run time, the HYDROSONIC will operate continuously as long as fluid
is present in the container, you can however set a predetermined run time from 1 minute to 10 hours. To set the
time use the (+) and (-) buttons until you have your desired time or you can set the HYDROSONIC to run
continuously, if you wish to do this set the run time to CONT. Once you have the correct settings depress ENTER
and the HYDROSONIC will start. If you wish to change any of the output settings you may do so while the
HYDROSONIC is running, simply follow the same instructions as before ensuring to depress ENTER when you
have the correct settings. The HYDROSONIC will now operate for the set time or until the fluid is used, you
may change the fluid container while the machine is running so not to stop the effect. If the HYDROSONIC
runs out of fluid the effect will stop and an error message will be displayed NOFL (no fluid) if this happens you
should restart the machine after changing the fluid container.
PAGE 7
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
OPERATING THE HYDROSONIC 2000
TURNING OFF
There is a routine for switching the HYDROSONIC off after you have finished using it. The main tank
should be emptied on a regular basis and should always be emptied when transporting the HYDROSONIC.
Failure to do so can reduce the performance of the HYDROSONIC. It is suggested that the main tank is emptied on a daily basis, after operating the HYDROSONIC depress the MENU button until ON is displayed, then
depress ENTER. EPTY will be displayed and the pump will reverse emptying the main tank into the fluid
container (you must ensure there is a maximum of 6.5 litres in the fluid container when emptying the main
tank). This operation takes approximately two minutes, after the tank is empty OFF will be displayed on the
controller and you can switch the HYDROSONIC off with the mains switch. If the HYDROSONIC is switched
off via the mains switch without the main tank been emptied on a regular basis the performance will detriate.
NOTE! ALWAYS CHECK THAT THERE IS LESS THAN 6.5 LITRES IN THE FLUID CONTAINER
BEFORE STARTING THE TURNING OFF SEQUENCE.
The HYDROSONIC may be left in a standby mode if you are planning on using it intermittently throughout the
day. There is no need to empty the main tank between the interval, simply select RUN on the controller display
by depressing the MENU and (+) buttons, depress ENTER and using the (-) button select "0" . Depress ENTER
and the machine will stop producing the effect. The HYDROSONIC is now in a standby mode with a correct
level of fluid in the main tank, when you wish to restart the HYDROSONIC select RUN on the display, depress
ENTER and set the desired run time using the (+) button. Once the correct time is displayed depress ENTER and
the effect will start.
PAGE 8
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
DMX 512
CONNECTING THE HYDROSONIC TO DMX 512
The HYDROSONIC 2000 has the capability of been controlled via DMX 512, TWO channels are required to
give control over the transducer output and the main fan output. Please see the diagrams below on how to
connect DMX 512 and the various controls.
FROM CONTROLLER
TO SECOND HYDROSONIC
TO NEXT HYDROSONIC
3
3
4
2
1
1
3
5
3
4
2
4
2
5
4
1
2
5
1
3
5
3
M ADE
MADE
2 SWISS1
2 SWI SS1
USEONLYWITHA250VFUSE
USEONLYWITHA250VFUSE
After connecting the HYDROSONIC to DMX you must set the onboard controller. Using the MENU button
and the (+) and (-) buttons select PSET on the display, depress enter and using the (+) button select SER1 and
depress ENTER, the HYDROSONIC is set to be controlled via DMX. You now have to set the DMX
address on the controller. Using the (+) & (-) buttons select DADR, now select the two channels required
i.e. hold down the (+) button until 100 is displayed then depress ENTER. The HYDROSONIC is set to run
off channel 100 and channel 101.
After you have finished using DMX you should reset the onboard controller, if you do not the HYDROSONIC
will not be controllable via the onboard controller. Select PSET again on the controller, depress ENTER, then
using the (+) button select AUTO, depress ENTER and the HYDROSONIC is ready to be controlled via the
onboard controller.
DMX DESCRIPTION
DMX CHANNEL OFFSET
"0"
"1"
EFFECT
DMX VALUES
0- 29
30- 59
60- 89
90- 109
110- 129
130- 149
150- 169
170- 189
190- 209
210- 229
230- 255
Idle
Pump out
Pump in
Transducers off
Transducers speed 1
Transducers speed 2
Transducers speed 3
Transducers speed 4
Transducers speed 5
Transducers speed 6
Transducers speed 7
0- 39
40- 75
75- 111
112- 147
148- 183
184- 219
220- 255
Fan off
Fan speed 1
Fan speed 2
(main fan control)
Fan speed 3
Fan speed 4
Fan speed 5
AUTO - sweeps between fan speeds 1 to 5
(pump control &
transducers)
PAGE 9
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
MARTIN PROTOCOL
CONNECTING THE HYDROSONIC TO MARTIN PROTOCOL
The HYDROSONIC 2000 has the capability of been controlled via MARTIN protocol, TWO channels are required to
give control over the transducer output and the main fan output. Please see the diagrams below on how to
connect MARTIN protocol and the various controls.
TO SECOND HYDROSONIC
3 PIN XLR
TO NEXT HYDROSONIC
3
2
4
1
5
FROM CONTROLLER
3
2
3
5
3
4
2
4
1
1
4
2
5
1
3
5
3
MADE
MADE
2 SWISS1
2SWISS1
USEONLYWITHA250VFUSE
USEONLYWITHA250VFUSE
After connecting the HYDROSONIC to MARTIN protocol you must set the onboard controller, using the
MENU button and the (+) and (-) buttons select PSET on the display, depress enter and using the (+) button
select SER2. Depress enter and the HYDROSONIC is set to be controlled via MARTIN protocol.
After you have finished using MARTIN protocol you should reset the onboard controller, if you do not the
HYDROSONIC will not be controllable via the onboard controller. Select PSET again on the controller,
depress ENTER, then using the (+) button select AUTO, depress ENTER and the HYDROSONIC is ready
to be controlled via the onboard controller.
MARTIN PROTOCOL DESCRIPTION
EFFECT
M.P. VALUES
MSB
(MOST SIGNIFICANT
BYTE)
LSB
(LEAST SIGNIFICANT
BYTE)
0- 29
30- 59
60- 89
90- 109
110- 129
130- 149
150- 169
170- 189
190- 209
210- 229
230- 255
Idle
Pump out
Pump in
Transducers off
Transducers speed 1
Transducers speed 2
Transducers speed 3
Transducers speed 4
Transducers speed 5
Transducers speed 6
Transducers speed 7
0- 39
40- 75
75- 111
112- 147
148- 183
184- 219
220- 255
Fan off
Fan speed 1
Fan speed 2
(main fan control)
Fan speed 3
Fan speed 4
Fan speed 5
AUTO - sweeps between fan speeds 1 to 5
(pump control &
transducers)
PAGE 10
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
MACHINE LAYOUT
REAR PANEL LAYOUT
9
1
3
2
4
1
5
2
3
2
4
5
REAR PANEL LAYOUT
1
3
8
4
3
MADE
2 SWISS1
5
6
7
USEONLYWITHA250VFUSE
1. DMX 512 IN connector
2. DMX 512 OUT connector
3. Martin Protocol IN connector
4. Martin Protocol OUT connector
5. Mains switch
6. Mains IEC connector
7. Fuse holder
8. Fluid level window
9. Airflow vents
10. Serial label
10
CONTROL PANEL LAYOUT
CONTROL PANEL LAYOUT
HOt
1. MENU BUTTON
2. ENTER BUTTON
3. (+) BUTTON
4. (-) BUTTON
5. DISPLAY
3
1
2
5
4
PAGE 11
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
MACHINE LAYOUT
MAIN FAN
TANK PRESSURE FAN
OUTPUT NOZZLE
FLUID PUMP
LIVEHEATSINK!
DONOTTOUCH.
CAUTION
LIVEHEATSINK!
DONOTTOUCH.
CAUTION
LIVEHEATSINK!
DONOTTOUCH.
CAUTION
LIVEHEATSINK!
DONOTTOUCH.
CAUTION
MAIN TANK
COOLING FAN
FLOAT SWITCH #1
FLOAT SWITCH #2
4 X POWER AMPLIFIER PCB's
TRANSFORMER
CONTROL PANEL
8.8.8.8.
HOT2000
CONTROLLER / DMX PCB
PUMP CONTROLLER PCB
(SHOWN REVERSED FOR CLARITY)
PAGE 12
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
SERVICE AND MAINTENANCE
HYDROSONIC ERROR MESSAGES
The HYDROSONIC has the ability to check the status of the electronics and reports any errors via the
onboard controller. Most of these errors are not serious and will only mean resetting the HYDROSONIC.
Listed below are the different error massages and a solution, please refer to this when you see an error
displayed on the controller.
ERROR MESSAGE
DESCRIPTION
SOLUTION
Restart the HYDROSONIC. If still displayed contact
your supplier for advice.
FrEr
Main fan not working
LoEr
Fluid level low
Check fluid level, add if low. Check machine is on a
level surface. It may be necessary to restart the machine.
FiEr
Pump fill timed out
Check fluid level, add if low. Check machine is on a
level surface. It may be necessary to restart the machine.
Err0 - Err3
Power amplifier PCB
not communicating
Restart the HYDROSONIC. If still displayed contact
your supplier for advice.
Er(x)(y)*
Power amplifier PCB
reports error
Restart the HYDROSONIC. If still displayed contact
your supplier for advice.
NoFL
No fluid in main tank
Add fluid if container is empty. Restart the machine.
*(x) = Power amplifier PCB (i.e. power amplifier PCB at address 0 has fault)
*(y) = An error code from 1-7
If any error messages are displayed your, HYDROSONIC will normally operate at a satisfactory level, you
may notice a slight reduction in output. If a serious error occurs the HYDROSONIC will shut down and no
effect will be visible. You should then contact the company who supplied the HYDROSONIC and ask for
advice, you may also contact JEM direct and speak to our service department.
NOTE! If there are surges or splikes down the mains supply ERR3 may be displayed.
PAGE 13
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
SERVICE & MAINTENANCE
CHANGING A PCB FUSE
NOTE! ALWAYS CHECK THAT THE HYDROSONIC IS DISCONNECTED FROM
THE MAINS BEFORE REPLACING A FUSE.
2 AMP SLOW BLOW
20 MM 250V FUSE
POWER AMPLIFIER PCB
(4 PER MACHINE)
8.8.8.8.
HOT 2000
1 AMP SLOW BLOW
20 MM 250V FUSE
315MA SLOW BLOW
20 MM 250V FUSE
CONTROLLER PCB
(1 PER MACHINE)
2 AMP SLOW BLOW
20MM 250V FUSE
1 AMP SLOW BLOW
20MM 250V FUSE
PUMP CONTROL PCB
(1 PER MACHINE)
NOTE! ALLAYS USE THE CORRECT RATING FUSE
PAGE 14
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
SERVICE & MAINTENANCE
CHANGING A POWER AMPLIFIER PCB
NOTE! ALWAYS CHECK THAT THE HYDROSONIC IS DISCONNECTED FROM
THE MAINS BEFORE ATTEMPTING ANY WORK.
POWER AMPLIFIER ADDRESS SETTING
If it becomes necessary to change a power amplifier PCB you must set the address to the same as the
one that you remove. Simply note the position of the jumpers on the board you remove and place
the jumpers in exactly the same position on the new PCB. Please look at the diagram below to see
the different address settings, and there position in the machine.
ADDRESS SETTINGS
POSITION IN MACHINE
ADDRESS "2"
ADDRESS "0"
ADDRESS "1"
ADDRESS "1"
LIVEHEATSINK!
LIVEHEATSINK!
DONOTTOUCH.
DONOTTOUCH.
CAUTION
C AU TION
L IVE HEATSINK!
DO NOT TOUCH.
LIVE HEATSINK!
DO NOT TOU CH.
ADDRESS "2"
C AU TION
CAUTION
ADDRESS "3"
ADDRESS "3"
ADDRESS "0"
PAGE 15
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSES
SOLUTION
Select PSET on the controller then
Machine will not fill the main
The onboard controller is set to be controlled depress ENTER, then using the (+)
tank when first switched on,
by DMX or MARTIN protocol.
button select AUTO and depress the
(FiLL) is not displayed.
ENTER button.
1. Check display for errors.
1. Fault on power amp PCB.
2. Activate tank evacuation and add
Low output from machine
2. Incorrect fluid concentrate.
fresh fluid.
even when on 100% output.
3. Machine on uneven surface.
3. Move machine to an even floor.
4. Transformer set to wrong setting.
4. Check and set to correct setting.
No display when switched
on.
1. No power supply connected.
2. Main fuse faulty.
3. Transformer set to wrong settings.
1. Connect to correct power supply
2. Check and replace main fuse if
faulty.
3. Check and set to correct settings.
Machine will not work when
connected to DMX 512.
1. Onboard controller is not set to run on
DMX 512.
2. The controller is not set to the correct
channels.
Check the controller settings as
described on page 9 of this manual.
Machine will not work when
connected to MARTIN
protocol.
1. Onboard controller is not set to run on
MARTIN protocol.
2. The controller is not set to the correct
channels.
Check the controller settings as
described on page 10 of this manual.
No main fan output even
when set to 100%.
Fuse blown on controller pcb
Check and replace fuses on the
controller pcb
If you cannot fix the fault by using this guide or the fault is not described you should contact the company who
sold you the HYDROSONIC, or contact JEM direct. Please do not attempt any work that you are not qualified
to do, it could result in serious damage to your machine.
NOTE! ALWAYS CHECK THAT THE HYDROSONIC IS DISCONNECTED FROM
THE MAINS BEFORE ATTEMPTING ANY WORK.
PAGE 16
JEM SMOKE PLC.
HYDROSONIC 2000 INSTRUCTION MANUAL
ADDITIONAL INFORMATION
ADDRESS
JEM SMOKE PLC
VALE ROAD INDUSTRIAL ESTATE,
BOSTON ROAD, SPILSBY,
LINCOLNSHIRE,
PE23 5HE,
ENGLAND.
TELEPHONE & FAX
TEL: (+44) (0) 1790 754050
FAX: (+44) (0) 1790 754051
E-MAIL ADDRESS
[email protected]
Please contact JEM if you require any further information regarding the HYDROSONIC or any
JEM product.