sDCM 300 Two Door Intelligent Serial Controller Host Communications

sDCM 300 Two Door Intelligent Serial Controller Host Communications
sDCM 300
Two Door Intelligent Serial Controller
Features that make a difference:
•
Support for two doors
•
RS485 host connection
•
Structured database allows storage of
large amounts of cardholder records for
off-line card validation
•
Reader communications via standard
Wiegand or Mag Stripe interfaces
•
Eight Supervised inputs (four
available per door)
•
Two Relays (normally opened or
normally closed)
•
Self resetting fuses – saves
maintenance time
•
Onboard LED - provides visual status
•
Dedicated Tamper input
The sDCM 300 (Door Control Module) is a
low cost, two-door controller designed to
interface third-party read heads with the
CEM range of access control systems.
The sDCM 300 communicates with the
host system via RS485 communications to
an S9032/64 serial controller or by TCP/
IP using the Ethernet Communications
Module (ECM). Using a powerful 32bit
processor, the sDCM 300 gives full
off-line validation and decision making
at the point of entry, even when host
communication is not available.
The sDCM 300 supports most third-party
access control read heads conforming to
the physical Wiegand/Mag Stripe (data/data)
interfaces covering a range of technologies,
for example RF Proximity. Customised
solutions are also available using two high
speed serial RS485/RS232 interfaces to
support non-standard devices such as,
read/write smartcards and crypto modules.
The sDCM 300 supports two door
configurations. It can either be
configured for two read heads on two
separate doors, with optional Exit
push buttons, or can be configured to
support an Entry/Exit configuration for
bi-directional control on a single door.
The TS100 is designed with internal
reading support for 13.56MHz
MiFare (CSN), DESFire (CSN), iClass
and iClass SE smart cards.
www.cemsys.com
Host Communications
The sDCM 300 utilises RS485
communications to connect to the
host controller, such as the CEM
S9032/64 controller. The ability to
connect to an Ethernet host controller
is provided by using the Ethernet
Communications Module (ECM).
Onboard Card Reading
Technologies
The sDCM 300 supports a wide range
of head technologies using the two
available onboard Wiegand connections.
Supported card technologies including
Wiegand 26bit, CEM 37bit, Mifare,
Corporate 1000 and many more.
Off-line Card Validation
The card database is initially downloaded
to the reader’s memory from the host
computer with subsequent changes to card
data automatically sent as updates. This
ensures that the reader has up-to-date
card information when operating in off-line
mode. Operating in off-line mode the reader
can hold in excess of 200,000 cards.
Easy to Install
The sDCM 300 is designed to be extremely
easy to install. After connection to the host
controller, configuration can be quickly
performed using the AC200 workstation
software, ensuring that the unit is up
and running in the shortest of time.
Specifications
Physical
Size
Board Only . . . . . . . . . . . . . 180 x 120 x 20mm (7.1” x 4.7” x 0.8”)
Enclosure . . . . . . . . . . . . . 460 x 250 x 90mm (18” x 10” x 3.5”)
Weight
Board Only . . . . . . . . . . . . . 0.1Kg
Enclosure . . . . . . . . . . . . . 5.00kg
Housing . . . . . . . . . . . . . . . . . Wall mount 1.2mm steel enclosure
Color . . . . . . . . . . . . . . . . . . . Gray
Power
Board Only
Voltage . . . . . . . . . . . . . . . . .
Current . . . . . . . . . . . . . . . .
Enclosure
Voltage . . . . . . . . . . . . . . . . .
Backup Battery . . . . . . . . . . .
11 – 15Vdc
170mA (excluding locks and heads)
220-230 VAC 50/60Hz.
Integral charging circuit provided with enclosure and space battery
(Battery not supplied).
Environmental
Temperature . . . . . . . . . . . . . . -10º to 55°C (14° to 131°F)
LED Indicators . . . . . . . . . . . . Power, Link to host, Comms Tx/Rx, Fault / Tamper, Lock and Relay Status
Functionality
Inputs . . . . . . . . . . . . . . . . . . . * Door Position
* Lock Status
* Exit Push Button
* General Purpose
Break Glass Sense
Fire Alarm Sense
Power Fail
Tamper
Battery Low (reported internally)
Dedicated Power Fail Input
* = 4 state tamper protected inputs
Outputs . . . . . . . . . . . . . . . . . Two 12V or 24V open collector outputs
limited to 1.5A (Door Lock and External Sounder) Two Relays rated at [email protected]
Reader capacity . . . . . . . . . . . 2 Weigand/Mag Stripe interfaces (data/
data, clock/data)
Configuration . . . . . . . . . . . . . Operational parameters are downloaded
from host computer
Database memory . . . . . . . . . 2GB SD Card
Cardholders . . . . . . . . . . . . . . Storage in excess of 200,000 cardholders at the door.
Transactions . . . . . . . . . . . . . . Up to 8,000 transactions in offline operation.
RTC Battery Backup . . . . . . . 3.0V rechargeable LithiumConfiguration . . . . . . . . . . . . . Operational parameters are downloaded from host computer.
Communication Interface
To Readers . . . . . . . . . . . . . . .
Connection . . . . . . . . . . . . . . .
To System Host . . . . . . . . . . .
Connection . . . . . . . . . . . . . . .
Weigand/Mag Stripe interface (data/data)
2 part screw terminals
RS485
Terminal
Ordering Information
Product Code
Description
DCM/310/006
sDCM 300 (Board Only)
DCM/310/101
sDCM 300 (Includes enclosure, board & power supply/battery charger)
* NOTE: AC2000 SE/AE/Lite version 5.7 required.
Related Products
AC2000
AC2000 Lite
AC2000 Airport
www.cemsys.com
© 2014 Tyco Security Products. All Rights Reserved. CEM/B/206 Rev D
Tyco and the product names listed above are marks and/or registered marks. Unauthorized use is strictly prohibited.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement