FSU1000 / FS100 Series Flashers Features:

FSU1000 / FS100 Series Flashers Features:
Flashers
FSU1000 / FS100 Series
The FSU1000 incorporates an onboard adjustable
flash rate of 10 to 100 FPM and a universal input
voltage in one device. Its circuitry is encapsulated
and is capable of controlling loads of up to 20A.
The versatility of the FSU1000 makes it ideal
for applications where various flash rates and
operating voltages are required.
Operation
When input voltage is applied to terminal 2 and the load
(lamp), the load energizes steadily. When input voltage
is applied to terminal 3, the output flashes.
Optional Low Current Switch (S1)
This low current switch could be a limit switch or contact.
While open, the operator sees the load (lamp) ON and
operating. When the limit switch closes, the load (lamp)
flashes to attract attention.
Order Table:
Rating
1A
6A
10A
20A
Inrush Rating
10A
60A
100A
200A
Part Number
FSU1000
FSU1003
FSU1004
FSU1005
For more information see:
Appendix A, page 164 for Flasher (NC) function.
Appendix B, page 165, Figure 4 for dimensional drawing.
Appendix C, page 168, Figure 1 for connection diagram.
Features:
• All solid state – no moving parts or contacts
• Onboard adjustable flash rate
• Loads up to 20A
• High inrush up to 200A
• Universal voltage 24 to 240VAC
Approvals:
Auxiliary Products:
• Female quick connect:
P/N: P1015-13 (AWG 10/12)
P/N: P1015-64 (AWG 14/16)
P/N: P1015-14 (AWG 18/22)
• Quick connect to screw adaptor:
P/N: P1015-18
Available Models:
FSU1000
FSU1003
FSU1004
Specifications
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . .
Flash Rate . . . . . . . . . . . . . . . . . . . . . . .
ON/OFF Ratio . . . . . . . . . . . . . . . . . . .
Input
Range/Frequency . . . . . . . . . . . . . . . .
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . .
Maximum Load Rating . . . . . . . . . . . .
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . .
ON/OFF recycling solid-state flasher (continuous duty)
Adjustable 10 - 100 FPM
≅ 50%
24 to 240VAC/50/60Hz
Inductive, resistive, or incandescent
1, 6, 10, or 20A steady state
10 times steady state current
Mechanical
Mounting* . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . .
Termination . . . . . . . . . . . . . . . . . . . . .
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . .
Environmental
Operating / Storage Temperature . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation
Upon application of input voltage, the T2 OFF time
begins. At the end of the OFF time, the T1 ON time begins
and the load energizes. At the end of T1, T2 begins and
the load de-energizes. This cycle repeats until input
voltage is removed.
Reset: Removing input voltage resets the output and the
sequence to T2 .
Output Rating
Specifications
1A
1A
2A
1A
1A
2A
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . .
Flash Rate . . . . . . . . . . . . . . . . . . . . . . .
Custom Flash Rates Available . . . . . .
ON/OFF Ratio . . . . . . . . . . . . . . . . . . .
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Line Frequency . . . . . . . . . . . . . . .
Output
Output . . . . . . . . . . . . . . . . . . . . . . . . . .
Load Type . . . . . . . . . . . . . . . . . . . . . . .
104
-20° to 60°C (240VAC +50°C) / -40° to 85°C
1A units: ≅ 2.4 oz (68 g)
> 6A units: ≅ 3.9 oz (111 g)
Features:
• Fixed flash rate 75 FPM
• Custom flash rate 45 - 150 FPM
• 1 or 2A output
• 24 or 120VAC
• Small size: 1.5 x 0.94 in. (38 x 23.9 mm)
Approvals:
Available Models:
FS126
FS126-45
FS126-60
FS126RC
FS126RC-90
FS127
FS146
FS146RC
For more information see:
Appendix A, page 164 for Flasher (OFF First) function.
Appendix B, page 165, Figure 12 for dimensional drawing.
Appendix C, page 168, Figure 2 for connection diagram.
Order Table:
Input
Encapsulated
*Units rated > 6A must be bolted to a metal surface using the included heat sink compound.
The maximum mounting surface temperature is 90°C.
The FS100 Series (low amp) may be used to control
inductive, incandescent or resistive loads. This
series offers a 1A (fullwave) or a 2A (halfwave)
steady state, 10A inrush solid-state output and
may be ordered with an input voltage of 24 or
120VAC. The FS100 Series offers a factory fixed
flash rate of 75 FPM or may be ordered with a fixed,
custom flash rate ranging from 45 to 150 FPM.
Ideal for OEM applications where cost is a factor.
120VAC
120VAC
120VAC
24VAC
24VAC
24VAC
Surface mount with one #10 (M5 x 0.8) screw
2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
0.25 in. (6.35 mm) male quick connect terminals
Output Type
AC, Fullwave
AC, Fullwave
AC, Halfwave
AC, Fullwave
AC, Fullwave
AC, Halfwave
Load Type*
A
B
A
A
B
A
Part Number
OFF/ON solid-state flasher (continuous duty)
Factory fixed at 75 FPM ±20%
From 45 - 150 FPM ±20%
≅ 50%
24, 120VAC, ±15%
50/60Hz
Fullwave AC or Halfwave rectified AC
Incandescent, resistive, or inductive
(Choose RC suffix for inductive loads)
FS126
FS126RC
FS127
FS146
FS146RC
FS147
*Load Type:
A-Incandescent & Resistive
B-Incandescent, Resistive & Inductive
Add the suffix “-##” to any part number to
indicate the custom flash rate.
Maximum Load Rating . . . . . . . . . . . . Fullwave: 1A steady state
Halfwave: 2A steady state
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . Removable mounting bracket, use one #8 (M4 x 0.7) screw
Connection/Wires . . . . . . . . . . . . . . . . 18 AWG (0.82mm2) wires 6 in. (15.2cm)
Dimensions . . . . . . . . . . . . . . . . . . . . . . 1.5 x 0.94 in. (38.1 x 23.9 mm)
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Environmental
Operating / Storage Temperature . . -20° to 60°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 1.1 oz (31 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement