Phase Control PHS Series The PHS Series is an ideal method of changing lamp intensity, varying the speed of a fan/ motor, or controlling the temperature of a heater. The effective output voltage is adjusted with an accessory external potentiometer suitable for line voltage applications. For more information see: Appendix B, page 165, Figure 4 for dimensional drawing. Appendix C, page 172, Figure 40 for connection diagram. Operation Upon application of input voltage, effective output voltage can be varied by changing the external resistance value. As the external resistance increases, the effective output voltage decreases. The inverse is also true. Typical Output Waveform Features: • External adjustment - 230VAC rated potentiometer • 120 or 230VAC input voltages available • Up to 20A steady state - 200A inrush • Single hole surface mounting Approvals: Auxiliary Products: • Versa-knob: P/N: P0700-7 • Quick connect t o s crew ad aptor: P/N: P1015-18 • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) P/N: P1015-14 (AWG 18/22) • Potentiometers: P/N: P1004-174 (100kΩ 1W) P/N: P1004-175 (200kΩ 2W) Available Models: PHS120A10 PHS120A20 PHS120A6 PHS230A1 PHS230A10 PHS230A20 PHS230A6 If desired part number is not listed, please call us to see if it is technically possible to build . Order Table: PHS X Input Voltage ─120A - 120VAC ─230A - 230VAC Specifications X Rating ─1 - 1A ─6 - 6A ─10 - 10A ─20 - 20A Output Mechanical Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Variable voltage phase angle control Mounting * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with one #10 (M5 x 0.8) screw Rating Steady State (at 100% On) Inrush* Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm) 1A 10A Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 in. (6.35 mm) male quick connect 6A 60A terminals 10A 100A Environmental 20A 200A Operating / Storage Temperature . . . . . . . . . . . -20° to 60°C / -40° to 85°C Minimum Load Current . . . . . . . . . . . . . . . . . . . . 100mA Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 2.0V at rated current Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A: ≅ 2.4 oz (68 g) Input 6, 10, & 20A: ≅ 3.9 oz (111 g) Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 or 230VAC External Adjustment Potentiometer Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20% 120VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100KΩ rated at 1W AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . 50/60Hz 230VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200KΩ rated at 2W Protection Must have insulation resistance suitable Dielectric Breakdown . . . . . . . . . . . . . . . . . . . . . . ≥ 2000V RMS terminals to mounting surface for line voltage applications. Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . ≥100MΩ *Units rated ≥ 6A must be bolted to a metal surface using the included heat sink compound. The maximum mounting surface temperature is 90°C. Inrush: Non-repetitive for 16ms. 148 www.ssac.com • 800-843-8848 • fax: 605-348-5685 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement