Voltage Monitors HLV Series The HLV Series is a single-phase undervoltage monitor designed to protect sensitive equipment from brownout or undervoltage conditions. Time delays are included to prevent nuisance tripping and short cycling. The 30A, 1hp rated, SPDT relay contacts allow direct control of motors, solenoids and valves. The output relay can be ordered with isolated SPDT contact to allow monitoring of one voltage and switching a separate voltage. Two undervoltage trip point ranges allow monitoring of 110 to 120VAC or 208 to 240VAC systems. For more information see: Appendix B, page 165, Figure 2 for dimensional drawing. Appendix C, page 169, Figure 15 for connection diagram. Operation Upon application of input voltage the output relay remains de-energized. When the input voltage value is above the pull-in voltage, the restart delay begins. At the end of the restart delay, the output relay energizes. When the input voltage falls below the trip point, the trip delay begins. If the input voltage remains below the pull-in voltage for the entire trip delay the relay de-energizes. If the input voltage returns to a value above the pull-in voltage, during the trip delay, the trip delay is reset and the relay remains energized. If the input voltage falls below the trip point voltage during the restart delay, the delay is reset and the relay remains de-energized. Reset is automatic upon correction of an undervoltage fault. Reset: Removing input voltage resets the output relay and the time delays. Features: • Protects against undervoltage in singlephase systems • 30A, SPDT, NO output contacts • 100 to 240VAC input voltage • 70 to 220VAC adjustable undervoltage trip point in 2 ranges • Restart delays from 3 - 300s • Trip delay 1 - 20s fixed • Isolated or non-isolated relay contacts Approvals: Auxiliary Products: • Quick connect to screw adaptor: P/N: P1015-18 • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) • Mounting bracket: P/N: P1023-6 • DIN rail: P/N: C103PM (Al) • DIN rail adaptor: P/N: P1023-20 Available Models: HLVA6I23 PI TP V C-NO C-NC If desired part number is not listed, please call us to see if it is technically possible to build . IV tr = Restart Delay td = Trip Delay PI = Pull-in 105% or trip point TP = Trip Point V = Monitored Voltage IV = Input voltage C-NO = Normally Open Contacts C-NC = Normally Closed Contacts Order Table: HLVA X Undervoltage Range ─4 - 70 to 120VAC ─6 - 170 to 220VAC X Output Connection ─I - Isolated SPDT ─N - Non-Isolated SPDT X Restart Delay ─2 - Onboard adjustment 3-300s X Trip Delay ─Fixed - Specify from 1-20s in 1s increments Specifications Input Min & Max RMS Voltage . . . . . . . . . . . . . . . .70 to 264VAC AC Line Frequency . . . . . . . . . . . . . . . . . . . . .50/60 Hz Power Consumption . . . . . . . . . . . . . . . . . . . .AC ≤ 4VA Undervoltage Sensing Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Peak voltage sensing Ranges (4) . . . . . . . . . . . . . .70 to 120VAC (6) . . . . . . . . . . . . . .170 to 220VAC Pull-In Voltage . . . . . . . . . . . . . . . . . . . . . . . . .105% or trip point voltage Trip Point Accuracy . . . . . . . . . . . . . . . . . . . . .± 3% of trip point Time Delay Restart Delays . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 300s adjustable Trip Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 20s fixed in 1s increments Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . .±0.5% or 20ms, whichever is greater Tolerance (Factory Calibration) . . . . . . . . . . .±5% Reset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . .≤ 150ms Time Delay vs. Temp. & Voltage . . . . . . . . . .≤ ±10% Output Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electromechanical relay Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SPDT www.ssac.com • 800-843-8848 • fax: 605-348-5685 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SPDT-N.O SPDT-NC General Purpose 125/240VAC 30A 15A Resistive 125/240VAC 30A 15A 28VDC 20A 10A Motor Load 125VAC 1 hp* 1/4 hp** 240VAC 2 hp** 1 hp** Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical - 1 x 106 Electrical - 1 x 105, *3 x104, **6,000 Protection Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEEE C62.41-1991 Level A Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated Isolation Voltage . . . . . . . . . . . . . . . . . . . . . . .≥ 1500V RMS input to output; isolated units Insulation Resistance . . . . . . . . . . . . . . . . . . . .≥ 100 MΩ Mechanical Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #10 (M5 x 0.8) screw Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 x 2 x 1.5 in. (76.7 x 51.3 x 38.1 mm) Termination . . . . . . . . . . . . . . . . . . . . . . . . . . .0.25 in. (6.35 mm) male quick connects Environmental Operating / Storage Temperature. . . . . . . . .-40° to 60°C / -40° to 85°C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% relative, non-condensing Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 3.9 oz (111 g) 119 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement