Liquid Level Controls LLC8 Series The LLC8 Series is a low cost, single-probe conductive liquid level control designed for low liquid level cutoff protection. It offers a factory fixed time delay of 1 - 60s and is available for input voltages of 24, 120, or 230VAC. LED indicator illuminates whenever the LLC8’s isolated, 10A, SPDT output relay is energized. Sense resistance is fixed from 5K - 250KΩ. Available with manual/ automatic reset or a special manual reset with a power outage feature that auto resets the unit when power is restored and the water level is acceptable. 24 and 120VAC units are UL recognized as limit switches under UL353 (230VAC units are UL 508) and CSA certified under Standard 14. For more information see: Appendix B, page 167, Figure 28 for dimensional drawing. Appendix C, page 170, Figure 25 for connection diagram. Operation Automatic Reset (Reset switch not connected): When liquid rises to low level cutoff probe, output relay and LED indicator energize. When liquid falls below the low level cutoff probe, the output relay and LED indicator de-energize after a fixed time delay. Manual Reset (Reset switch connected): When the liquid level falls below low level probe, the output relay and LED de-energize after a fixed time delay. When the liquid level rises to low level probe, the output relay and LED indicator remain de-energized until the NC manual reset switch is opened; then they energize immediately. Power Outage Manual Reset (Reset switch connected): A power outage causes the output relay and LED indicator to de-energize. Upon restoration of power, if the liquid is touching the low level probe, the output relay and LED indicator will re-energize. If the liquid level is below the low level probe, the output relay and LED indicator remain de-energized until the NC reset switch is opened. Order Table: LLC8 X Input ─2 - 24VAC ─4 - 120VAC ─6 - 230VAC X TimeDelay(fixed) ─Specify fixed delay in seconds (1-60) in 1s increments X Sense Resistance ─F - Fixed (Specify fixed resistance in kilohms (5-250) in 1K increments .) Features: • Designed for low level cutoff protection • Energized on wet probe • Fixed time delay 1 - 60s • Fixed sense resistance of 5K - 250KΩ • 24, 120, or 230VAC input voltages available • Isolated, 10A, SPDT output contacts Approvals: Auxiliary Products: • Quick connect t o s crew ad aptor: P/N: P1015-18 • Electrode: P/N: PHST-38QTN • Threaded probe (24”): P/N: LLP-24 • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) P/N: P1015-14 (AWG 18/22) Available Models: LLC825F5M LLC843F10M LLC843F10P LLC843F26M LLC843F26P LLC845F25P LLC8610F12M If desired part number is not listed, please call us to see if it is technically possible to build . X Reset ─M - Manual/Automatic Reset ─P - Power outage manual reset Specifications Control Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sense Voltage . . . . . . . . . . . . . . . . . . . . . . . . . Sense Resistance . . . . . . . . . . . . . . . . . . . . . . . Sense Resistance Tolerance . . . . . . . . . . . . . Time Delay Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . Time Delay vs Temp. & Voltage . . . . . . . . . Power Outage Reset Delay . . . . . . . . . . . . . . Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tolerance 24VAC . . . . 120 or 230VAC . . . . . AC Line Frequency . . . . . . . . . . . . . . . . . . . . Output Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Resistance sensing for conductive liquids with time delay 12VAC nominal at probe terminals Fixed 5K - 250KΩ ±10% ±20% ±10% ±10% ≤1s 24, 120, or 230VAC -15% - 20% -20% - 10% 50/60 Hz Protection Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEEE C62.41-1991 Level A Isolation Voltage . . . . . . . . . . . . . . . . . . . . . . ≥ 2500V RMS input to output terminals Mechanical Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 in. (12.7 mm) x .187 (4.76 mm) dia. nylon standoffs (3) Termination Electrical . . . . . . 0.25 in. (6.35 mm) male quick connect terminals Reset Switch & Probe(s) . . . . . . 0.187 x 0.03 in. (4.75 x 0.76 mm) male quick connect terminals Environmental Operating / Storage Temperature . . . . . . . -40° to 60°C / -40° to 80°C Coating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Printed circuit board is conformal coated to resist moisture & corrosion Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 5 oz (141.7 g) Electromechanical relay Isolated SPDT 10A resistive @ 120/240VAC; 1/4 hp @ 125VAC; 1/2 hp @ 250VAC www.ssac.com • 800-843-8848 • fax: 605-348-5685 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement