Timer - Percentage PTHF Series The PTHF Series can be used for a variety of applications from chemical metering, to temperature regulating, to energy management. The infinite adjustability from 1 to 99% provides accurate percentage on control over a wide factory fixed cycle period. When mounted on a metal surface, it can be used to drive solenoids, contactors, relays, or lamps, up to 20A steady, 200A inrush. PTHF is the suggested replacement for the PT Series. Operation (Percentage): Upon application of input voltage, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the T2 OFF time begins. At the end of the OFF time, the output energizes and the cycle repeats as long as input voltage is applied. Increasing the ON time decreases the OFF time. The total cycle period is equal to the ON time plus the OFF time. The total cycle period is factory fixed. ON time range is 1 to 99 percent of cycle period. Reset: Removing input voltage resets the output and time delays, and returns the sequence to the T1 ON time. Connection: L1 N/L2 For more information see: Appendix A, pages 156-164 for function descriptions and diagrams . Appendix B, page 165, Figure 4 for dimensional drawing. Features • ON/OFF recycling percentage control • Controls loads up to 20A, 200A inrush • Fixed cycle period 10s - 1000m • ±0.5% repeat accuracy • ±5% factory calibration • Totally solid state & encapsulated • Onboard or external adjustment 1 - 99% ON Approvals: Auxiliary Products: • External ad just potentiometer: P/N: P1004-95 • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) • Quick connect t o s crew ad aptor: P/N: P1015-18 • Versa-knob: P/N: P0700-7 Available Models: PTHF410C PTHF410CK PTHF4120D PTHF615A If desired part number is not listed, please call us to see if it is technically possible to build . RT = 100 KΩ S1 = Optional Low Current Initiate Switch T1 = ON Time T2 = OFF Time RT is used when external adjustment is ordered. Order Table: PTHF X Input Voltage ─2 - 24VAC ─4 - 120VAC ─6 - 230VAC X Fixed Cycle Period ─Specify 10 - 1000 as the total fixed cycle period in seconds . If cycle period is in minutes insert (M) suffix. X Output Rating ─A - 6A ─B - 10A ─C - 20A ─D - 1A X Adjustment ─Blank - External adjust ─K - Onboard adjust Specifications Time Delay Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .External or onboard knob Range / External Adjustment Resistance . . . . . .Adjustable from 1 - 99% / RT = 100 KΩ Cycle Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fixed from 10s - 1000m Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . .±0.5% or 20ms, whichever is greater Cycle Period Tolerance (Factory Calibration) . . .≤ ± 5% Reset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≤ 150ms Time Delay vs Temp. & Voltage . . . . . . . . . . . . . .≤ ±10% Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24, 120, or 230VAC Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±20% AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . .50/60 Hz Power Consumption . . . . . . . . . . . . . . . . . . . . . . . .≤ 2VA Output Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solid state Maximum Load Currents Output Steady State Inrush* Minimum A 6A 60A 100mA B 10A 100A 100mA C 20A 200A 100mA D 1A 10A -- 92 Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 2.5V at rated current OFF State Leakage Current . . . . . . . . . . . . . . . . . .≅ 5mA @ 230VAC Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated Dielectric Breakdown . . . . . . . . . . . . . . . . . . . . . . .≥ 2000V RMS terminals to mounting surface Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . .≥ 100 MΩ Mechanical Mounting * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #10 (M5 x 0.8) screw Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm) Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.25 in. (6.35 mm) male quick connect terminals Environmental Operating / Storage Temperature . . . . . . . . . . . .-40° to 60°C / -40° to 85°C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% relative, non-condensing Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1A unit: ≅ 2.4 oz (68 g); 6, 10, 20A units: ≅ 3.9 oz (111 g) *Units rated ≥ 6A must be bolted to a metal surface using the included heat sink compound. The maximum mounting surface temperature is 90°C. Inrush: Non-repetitive for 16ms. www.ssac.com • 800-843-8848 • fax: 605-348-5685 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement