RS Series
The RS Series is a solid-state, encapsulated,
recycling timer designed for tough industrial
environments. It is used by many testing labs as
a life cycle tester; by others as a cycle controller.
The RS Series has separate DIP switch adjustments
for the on delay and the off delay. These make
accurate adjustment possible the first time, every
time. Time delays of 0.1 seconds to 1023 hours are
available in 4 ranges.
Operation (Recycling - ON Time First)
Upon application of input voltage, the output energizes
and the T1 ON time begins. At the end of the ON time, the
output de-energizes and the T2 OFF time begins. At the
end of the OFF time, the output energizes and the cycle
repeats as long as input voltage is applied.
Reset: Removing input voltage resets the output and time
delays, and returns the sequence to the ON time.
Operation (Recycling - OFF Time First)
Upon application of input voltage, the T2 OFF time
begins. At the end of the OFF time, the output energizes
and the T1 ON time begins. At the end of the ON time,
the output de-energizes and the cycle repeats as long as
input voltage is applied.
Reset: Removing input voltage resets the output and time
delays, and returns the sequence to the OFF time.
Connection:
L1
N/L2
For more information see:
Appendix A, pages 156-164 for function descriptions
and diagrams .
Appendix B, page 165, Figure 2 for dimensional drawing.
Features:
• Accurate, reliable, recycling timer
• Switch settable time delays - both times
adjustable
• ±0.1% repeat accuracy
• ±2% setting accuracy
• 0.1s - 1023h in 4 ranges
• 12 to 230V in 5 options
• 1A, solid-state output
• Totally solid state and encapsulated
Approvals:
Auxiliary Products:
• Female quick connect:
P/N: P1015-64 (AWG 14/16)
• Quick connect t o s crew ad aptor:
P/N: P1015-18
• Mounting bracket: P/N: P1023-6
• DIN rail: P/N: C103PM (Al)
• DIN rail adaptor: P/N: P1023-20
Available Models:
RS1A11
RS1A12
RS1B12
RS2A12
RS2A24
RS2B44
RS4A11
RS4A12
RS4A13
RS4A22
RS4A24
RS4A31
RS4A33
RS4B23
RS6A13
RS6A24
If desired part number is not listed, please call us to
see if it is technically possible to build .
L = Load
Order Table:
RS
X
Input Voltage
─1 - 12VDC
─2 - 24VAC
─3 - 24VDC
─4 - 120VAC
─6 - 230VAC
X
Operating Sequence
─A - ON time first
─B - OFF time first
X
T1 ON Time
─1 - 0.1 - 102.3s in
0.1s increments
─2 - 0.1 - 102.3m in
0.1m increments
─3 - 1 - 1023m in
1m increments
─4 - 1 - 1023h in
1h increments
X
T2 OFF Time
─1 - 0.1 - 102.3s in
0.1s increments
─2 - 0.1 - 102.3m in
0.1m increments
─3 - 1 - 1023m in
1m increments
─4 - 1 - 1023h in
1h increments
Specifications
Time Delay
Range* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 - 102.3s in 0.1s increments
0.1 - 102.3m in 0.1m increments
1 - 1023m in 1m increments
1 - 1023h in 1h increments
Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . . ±0.1% or 20ms, whichever is greater
Setting Accuracy . . . . . . . . . . . . . . . . . . . . . . . . < ±2% or 20ms, whichever is greater
Reset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 150ms
Time Delay vs Temp. & Voltage . . . . . . . . . . . < ± 2%
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12, or 24VDC; 24, 120, or 230VAC
Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20%
AC Line Frequency / DC Ripple . . . . . . . . . . . 50/60 Hz / < ±10%
Power Consumption . . . . . . . . . . . . . . . . . . . . . AC < 2VA; DC < 1W
Output
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solid state
Maximum Load Current . . . . . . . . . . . . . . . . . . 1A steady state, 10A inrush at 60°C
www.ssac.com • 800-843-8848 • fax: 605-348-5685
OFF State Leakage Current . . . . . . . . . . . . . . .
Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dielectric Breakdown . . . . . . . . . . . . . . . . . . . .
Insulation Resistance . . . . . . . . . . . . . . . . . . . . .
Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental
Operating / Storage Temperature . . . . . . . . .
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC ≅ 5mA @ 230VAC; DC ≅ 1mA
AC ≅ 2.5V @ 1A; DC ≅ 1V @ 1A
Encapsulated
≥ 2000V RMS terminals to mounting surface
≥ 100 MΩ
DC units are reverse polarity protected
Surface mount with one #10 (M5 x 0.8) screw
3 x 2 x 1.5 in (76.7 x 51.3 x 38.1 mm)
0.25 in. (6.35 mm) male quick connect terminals
-40° to 75°C / -40° to 85°C
95% relative, non-condensing
≅ 3.9 oz (111 g)
*For CE approved applications, power must be removed from the unit when a switch position