Timer - Delay-on-Make TH1 Series The TH1 Series is a solid-state relay and timer combined into one compact, easy-to-use control. This highly reliable device eliminates the need for a separate solid-state relay. When mounted to a metal surface, it can switch load currents up to 20A steady state, and 200A inrush. Operation (Delay-on-Make): Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed. Reset: Removing input voltage resets the time delay and output . For more information see: Appendix A, pages 156-164 for function descriptions and diagrams . Appendix B, page 165, Figure 4 for dimensional drawing. Connection: L1 N/L2 Features: • High current load capacity up to 20A with 200A inrush • Solid-state switching - no contact wear or arcing • Encapsulated • Fixed or adjustable time delays from 0.1 - 600s • ± 2% repeat accuracy • ± 5% factory calibration • Metallized mounting surface for heat transfer Approvals: Auxiliary Products: • External ad just potentiometer: P/N: P1004-95 P/N: P1004-95-X • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) • Quick connect t o s crew ad aptor: P/N: P1015-18 • Versa-knob: P/N: P0700-7 Available Models: TH1A421 TH1B633 TH1C415 TH1C621 If desired part number is not listed, please call us to see if it is technically possible to build . S1 = Optional Low Current Initiate Switch RT is used when external adjustment is ordered. Order Table: TH1 X Output Rating ─A - 6A ─B - 10A ─C - 20A X Input Voltage ─2 - 24VAC ─4 - 120VAC ─6 - 230VAC X Adjustment ─1 - Fixed ─2 - External adjust ─3 - Onboard adjust X Time Delay* ─1 - 0.1 - 3s ─2 - 0.5 - 60s ─3 - 2 - 180s ─4 - 5 - 600s *If fixed delay is selected, insert delay (0 .1 - 600) in secs . Specifications Time Delay Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . . Tolerance (Factory Calibration) . . . . . . . . . . . . Time Delay vs Temp. & Voltage . . . . . . . . . . . Recycle Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . Power Consumption . . . . . . . . . . . . . . . . . . . . . Output Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum Load Currents Output A B C 0.1 - 600s in 4 adjustable ranges or fixed ±2% or 20ms, whichever is greater ≤ ± 5% ≤ ±10% ≤ 150ms 24, 120, or 230VAC ±15% 50/60 Hz ≤ 2VA Solid state NO, open during timing Steady State 6A 10A 20A www.ssac.com • 800-843-8848 • fax: 605-348-5685 Inrush** 60A 100A 200A Minimum Load Current . . . . . . . . . . . . . . . . . . Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF State Leakage Current . . . . . . . . . . . . . . . Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dielectric Breakdown . . . . . . . . . . . . . . . . . . . . Insulation Resistance . . . . . . . . . . . . . . . . . . . . . Mechanical Mounting ** . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Operating / Storage Temperature . . . . . . . . . Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100mA ≅ 2.5V at rated current ≅ 5mA @ 230VAC Encapsulated ≥ 2000V RMS terminals to mounting surface ≥ 100 MΩ Surface mount with one #10 (M5 x 0.8) screw 2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm) 0.25 in. (6.35 mm) male quick connect terminals -20° to 60°C / -40° to 85°C 95% relative, non-condensing ≅ 3.9 oz (111 g) **Must be bolted to a metal surface using the included heat sink compound. The maximum mounting surface temperature is 90°C. Inrush: Non-repetitive for 16ms. 35 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement