Timer - Interval TH2 Series The TH2 is the combination of a timer and a solidstate relay into one easy-to-use solid-state molded module. When mounted to a metal surface, the TH2 Series can switch load currents up to 20A steady state with 200A inrush. The TH2 replaces a timer and relay at a competitive price. Operation (Interval): Upon application of input voltage, the time delay begins. The output energizes during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed. Reset: Removing input voltage resets the time delay and output . Connection: L1 For more information see: Appendix A, pages 156-164 for function descriptions and diagrams . Appendix B, page 165, Figure 4 for dimensional drawing. N/L2 Features • High load current capacity up to 20A, 200A inrush • Fixed or adjustable time delays from 0.1 600s in 4 ranges • ±2% repeat accuracy • ±5% factory calibration • Metallized mounting surface for heat transfer • Solid state & encapsulated Approvals: Auxiliary Products: • External ad just potentiometer: P/N: P1004-95 P/N: P1004-95-X • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) • Quick connect t o s crew ad aptor: P/N: P1015-18 • Versa-knob: P/N: P0700-7 Available Models: TH2A421 If desired part number is not listed, please call us to see if it is technically possible to build . RT is used when external adjustment is ordered. Order Table: TH2 X Output Rating ─A - 6A ─B - 10A ─C - 20A X Input Voltage ─2 - 24VAC ─4 - 120VAC ─6 - 230VAC X Adjustment ─1 - Fixed ─2 - External adjust ─3 - Onboard adjust X Time Delay* ─1 - 0.1 - 3s ─2 - 0.5 - 60s ─3 - 2 - 180s ─4 - 5 - 600s *If fixed delay is selected, insert delay (0 .1 - 600) in seconds . Specifications Time Delay Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.1s - 600s in 4 adjustable ranges, or fixed Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . .±2% or 20ms, whichever is greater Tolerance (Factory Calibration) . . . . . . . . . . . . . . .≤ ±5% Time Delay vs Temp. & Voltage . . . . . . . . . . . . . .≤ ±10% Reset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≤ 150ms Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24, 120, or 230VAC Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±15% AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . .50/60 Hz Power Consumption . . . . . . . . . . . . . . . . . . . . . . . .≤ 2VA Output Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Solid state Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NO, closed during timing Maximum Load Currents Output Steady State Inrush** A 6A 60A B 10A 100A C 20A 200A 78 Minimum Load Current . . . . . . . . . . . . . . . . . . . . .100mA Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 2.5V at rated current OFF State Leakage Current . . . . . . . . . . . . . . . . . .≅ 5mA @ 230VAC Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated Dielectric Breakdown . . . . . . . . . . . . . . . . . . . . . . .≥ 2000V RMS terminals to mounting surface Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . .≥ 100 MΩ Mechanical Mounting ** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #10 (M5 x 0.8) screw Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm) Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.25 in. (6.35 mm) male quick connect terminals Environmental Operating / Storage Temperature . . . . . . . . . . . .-20° to 60°C / -40° to 85°C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% relative, non-condensing Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 3.9 oz (111 g) **Must be bolted to a metal surface using the included heat sink compound. The maximum mounting surface temperature is 90°C. Inrush: Non-repetitive for 16ms. www.ssac.com • 800-843-8848 • fax: 605-348-5685 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement