Timer - Delay-on-Break THDB Series The THDB Series combines accurate timing circuitry with high power, solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use, Digi-Power timers. Operation (Delay-on-Break): Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output energizes. The time delay begins when the initiate switch is opened. The output remains energized during timing. At the end of the time delay, the output de-energizes. The output energizes if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output . Connection: L1 For more information see: Appendix A, pages 156-164 for function descriptions and diagrams . Appendix B, page 165, Figure 4 for dimensional drawing. N/L2 External Resistance vs . Time Delay: THDB X Input Voltage ─2 - 24VAC ─4 - 120VAC ─6 - 230VAC X Adjustment ─1 - Fixed ─2 - External adjust ─3 - Onboard adjust • High load currents up to 20A, 200A inrush • Fixed or adjustable 0.1s - 1000m in 6 ranges • ±0.5% repeat accuracy • ±1% factory calibration • 24, 120, or 230VAC • Metallized mounting surface for heat transfer • Totally solid-state & encapsulated Approvals: Auxiliary Products: • External ad just potentiometer: P/N: P1004-95 P/N: P1004-95-X • Female quick connect: P/N: P1015-13 (AWG 10/12) P/N: P1015-64 (AWG 14/16) • Quick connect t o s crew ad aptor: P/N: P1015-18 • Versa-knob: P/N: P0700-7 Available Models: THDB430C THDB231C THDB431C THDB232C THDB432C THDB233C THDB433C THDB234C THDB434C THDB235C THDB435C THDB4110MC THDB421A If desired part number is not listed, please call us to see if it is technically possible to build . UTL = Optional Untimed Load L = Timed Load S1 = Initiate Switch RT is used when external adjustment is ordered. Order Table: Features: X Time Delay* ─0 - 0.1 - 10s ─1 - 1 - 100s ─2 - 10 - 1000s ─3 - 0.1 - 10m ─4 - 1 - 100m ─5 - 10 - 1000m X Output Rating ─A - 6A ─B - 10A ─C - 20A *If fixed delay is selected, insert delay (0 .1 - 1000) followed by (S) sec . or (M) min . Specifications Time Delay Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1s - 1000m in 6 adjustable ranges or fixed Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . ±0.5% or 20ms, whichever is greater Tolerance (Factory Calibration) . . . . . . . . . . . ≤ ±1% Reset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 150ms Initiate Time . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 20ms Time Delay vs Temp. & Voltage . . . . . . . . . . ≤ ±2% Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 120, or 230VAC Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20% AC Line Frequency . . . . . . . . . . . . . . . . . . . . . 50/60 Hz Power Consumption . . . . . . . . . . . . . . . . . . . . ≤ 2VA Output Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solid state Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO, closed before & during timing Maximum Load Current Output Steady State Inrush** A 6A 60A B 10A 100A C 20A 200A www.ssac.com • 800-843-8848 • fax: 605-348-5685 Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 2.5V @ rated current Off State Leakage Current . . . . . . . . . . . . . . . ≅ 5mA @t 230VAC Minimum Load Current . . . . . . . . . . . . . . . . . 100mA Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated Dielectric Breakdown . . . . . . . . . . . . . . . . . . . ≥ 2000V RMS terminals to mounting surface Insulation Resistance . . . . . . . . . . . . . . . . . . . . ≥ 100 MΩ Mechanical Mounting ** . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with one #10 (M5 x 0.8) screw Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm) Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 in. (6.35 mm) male quick connect terminals Environmental Operating / Storage Temperature . . . . . . . . -40° to 60°C / -40° to 85°C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 3.9 oz (111 g) **Must be bolted to a metal surface using the included heat sink compound. The maximum surface temperature is 90°C. Inrush: Non-repetitive for 16ms. 49 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement