THDS Series Timer - Single Shot

THDS Series Timer - Single Shot
Timer - Single Shot
THDS Series
The THDS Series combines accurate timing
circuitry with high power solid-state switching.
It can switch motors, lamps, and heaters directly
without a contactor. You can reduce labor,
component cost, and increase reliability with these
small, easy-to-use, Digi-Power timers.
Operation (Single Shot):
Input voltage must be applied before and during timing.
Upon momentary or maintained closure of the initiate
switch, the output energizes for a measured interval of
time. At the end of the delay, the output de-energizes.
Opening or reclosing the initiate switch during timing
has no affect on the time delay. The output energizes if
the initiate switch is closed when input voltage is applied.
Reset: Reset occurs when the time delay is complete and
the initiate switch is opened. Loss of input voltage resets
the time delay and output.
Connection:
L1
For more information see:
Appendix A, pages 156-164 for function descriptions
and diagrams .
Appendix B, page 165, Figure 4 for dimensional drawing.
N/L2
External Resistance vs . Time Delay:
Features:
• High load currents up to 20A, 200A inrush
• Fixed or adjustable delays from 0.1s - 1000m
• ±0.5% repeat accuracy
• ±1% factory calibration
• 24, 120, or 230VAC
• Metallized mounting surface for heat
transfer
• Totally solid state and encapsulated
Approvals:
Auxiliary Products:
• External ad just potentiometer:
P/N: P1004-95
P/N: P1004-95-X
• Female quick connect:
P/N: P1015-13 (AWG 10/12)
P/N: P1015-64 (AWG 14/16)
• Quick connect t o s crew ad aptor:
P/N: P1015-18
• Versa-knob: P/N: P0700-7
Available Models:
THDS230C
THDS231C
THDS232C
THDS233C
THDS234C
THDS235C
THDS410.25SA
THDS411.5SA
THDS414MC
UTL = Optional Untimed Load
L = Timed Load
S1 = Initiate Switch
If desired part number is not listed, please call us to
see if it is technically possible to build .
RT is used when external adjustment is ordered.
Order Table:
THDS
X
Input Voltage
─2 - 24VAC
─4 - 120VAC
─6 - 230VAC
X
Adjustment
─1 - Fixed
─2 - External adjust
─3 - Onboard adjust
THDS420B
THDS430C
THDS432C
THDS433C
THDS434C
THDS435C
THDS610.25SA
THDS611.5SA
X
Time Delay*
─0 - 0.1 - 10s
─1 - 1 - 100s
─2 - 10 - 1000s
─3 - 0.1 - 10m
─4 - 1 - 100m
─5 - 10 - 1000m
X
Output Rating
─A - 6A
─B - 10A
─C - 20A
*If fixed delay is selected, insert
delay (0 .1 - 1000) followed by (S) sec .
or (M) min .
Specifications
Time Delay
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1s - 1000m in 6 adjustable ranges or fixed
Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . . ±0.5% or 20ms, whichever is greater
Tolerance (Factory Calibration) . . . . . . . . . . . . ≤ ±1%
Reset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤150ms
Initiate Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 20ms
Time Delay vs Temp. & Voltage . . . . . . . . . . . ≤ ±2%
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 120, or 230VAC
Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20%
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz
Power Consumption . . . . . . . . . . . . . . . . . . . . . ≤ 2VA
Output
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solid state
Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO, closed during timing
Maximum Load Current
Output
Steady State
Inrush**
A
6A
60A
B
10A
100A
C
20A
200A
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 2.5V @ rated current
Off State Leakage Current . . . . . . . . . . . . . . . . ≅ 5mA @ 230VAC
Minimum Load Current . . . . . . . . . . . . . . . . . . 100mA
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Dielectric Breakdown . . . . . . . . . . . . . . . . . . . . ≥ 2000V RMS terminals to mounting surface
Insulation Resistance . . . . . . . . . . . . . . . . . . . . . ≥ 100 MΩ
Mechanical
Mounting ** . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with one #10 (M5 x 0.8) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating / Storage Temperature . . . . . . . . . -40° to 60°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 3.9 oz (111 g)
**Must be bolted to a metal surface using the included heat sink compound. The maximum
mounting surface temperature is 90°C. Inrush: Non-repetitive for 16ms.