Timer - Lockout TL Series The TL Series provides protection against short cycling of a compressor. At the end of each operation, or whenever power is lost, a lockout delay is initiated. This lockout delay prevents restarting of the compressor until the head pressure has equalized. Compressor relay chatter due to thermostat bounce is eliminated by use of optional one second delay-on-make. The TL Series should not be used with cooling anticipator resistors or solid-state switches. (See the TA Series) . Connection: L1 Operation (Lockout): Lockout: On initial closure of S1, the compressor relay energizes immediately (or after an optional 1 s delay). When the S1 opens or input voltage is interrupted, the output opens and remains open for the lockout time delay. During this lockout time delay period, the compressor relay cannot be re-energized. Reset: The lockout time delay cannot be reset. After the time delay is completed, the unit automatically resets. N/L2 For more information see: Appendix A, pages 156-164 for function descriptions and diagrams . Appendix B, page 165, Figure 1 for dimensional drawing. Features • Ideal for HVAC/R applications • Lockout delay prevents short cycling of a compressor • Optional 1s delay-on-make prevents contactor chatter • Totally solid state and encapsulated • 24VAC to 230VAC in 3 ranges • Eliminates nuisance service calls due to blown fuse or tripped breakers Approvals: Auxiliary Products: • Female quick connect: P/N: P1015-64 (AWG 14/16) • Mounting bracket: P/N: P1023-6 • Quick connect t o s crew ad aptor: P/N: P1015-18 • DIN rail: P/N: C103PM (Al) • DIN rail adaptor: P/N: P1023-20 Available Models: TL120A5T TL230A5 TL230A5T TL24A5 If desired part number is not listed, please call us to see if it is technically possible to build . V = Voltage S1 = Initiate Switch CR = Compressor or Control Relay Order Table: TL X Input Voltage ─24A - 24VAC ─120A - 120VAC ─230A - 230VAC X Lockout Time ─2 - 2m ─3 - 3m ─5 - 5m X Delay-on-Make ─Blank - No delay ─T - 1s Specifications Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Line Frequency . . . . . . . . . . . . . . . . Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . Output Minimum Load Current . . . . . . . . . . . . Maximum Load Current . . . . . . . . . . . . Inrush Current . . . . . . . . . . . . . . . . . . . . Voltage Drop . . . . . . . . . . . . . . . . . . . . . Time Delay Initiate Time . . . . . . . . . . . . . . . . . . . . . . Lockout Time* . . . . . . . . . . . . . . . . . . . . Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . Option . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 24, 120, or 230VAC 50/60 Hz ±20% ≤ 40mA 1A @ 24VAC; 0.5A @ 120 & 230VAC at 60°C 10A at 60°C 24VAC - 2.5V @ 1A 120 & 230VAC - 4.2V @ 0.5A ≅ 8ms Fixed 2, 3, or 5m -15% - 35% 1s delay-on-make eliminates contactor chatter due to thermostat bounce Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . Dielectric Breakdown . . . . . . . . . . . . . . Insulation Resistance . . . . . . . . . . . . . . . Mechanical Mounting . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . Termination . . . . . . . . . . . . . . . . . . . . . . Environmental Operating / Storage Temperature . . . Humidity . . . . . . . . . . . . . . . . . . . . . . . . . Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated ≥ 2000V RMS terminals to mounting surface ≥ 100 MΩ Surface mount with one #10 (M5 x 0.8) screw 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) 0.25 in. (6.35 mm) male quick connect terminals -40° to 70°C / -40° to 85°C 95% relative, non-condensing ≅ 2.4 oz (68 g) *Power must be applied for at least 15 s to achieve a full lockout delay. Less than 15s will result in proportionally shorter delay periods. NOTE: Cooling anticipator resistor or leakage may cause erratic operation. See TA Series for use with 24VAC systems that include anticipator resistors or use solid-state switches. www.ssac.com • 800-843-8848 • fax: 605-348-5685 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement