Lochinvar CGL200, CGN150, CGL150, CGN200 Manual

Lochinvar CGL200, CGN150, CGL150, CGN200 Manual

MODELS CG(N,L)150 & CG(N,L)200

COMMERCIAL GAS, GLASS-LINED, TANK-TYPE WATER HEATER

• INSTALLATION • OPERATION • MAINTENANCE • LIMITED WARRANTY

Thank you for buying this energy efficient water heater. We appreciate your confidence in our products.

CAUTION

TEXT IN BLACK BOLD TYPE OR UNDERLINED CONTAINS

INFORMATION RELATIVE TO YOUR SAFETY. PLEASE READ

THOROUGHLY BEFORE INSTALLING AND USING THIS

APPLIANCE.

Printed in U.S.A. 1011

300 Maddox Simpson Parkway

Lebanon, TN 37090

Phone: 615-889-8900 • Fax: 615-547-1000

Technical Service email: [email protected]

www.Lochinvar.com

PLACE THESE INSTRUCTIONS ADJACENT TO HEATER

AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.

1

322880-000

ROUGH-IN-DIMENSIONS

FIGURE 1

TABLE 1 - HEATER PERFORMANCE DATA

Model

Input

Rate

Btuh

Approx.

Tank Approx. F 20°F 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F

Cap.

CGN150032 150,000 NAT 32 Gal

Eff. %

C 11°C 17°C 22°C 28°C 33°C 39°C 44°C 50°C 56°C 61°C 67°C 72°C 78°C

80

RECOVERY RATING CAPACITIES (GPH) AT TEMPERATURE RISE SHOWN

GPH 727 485 364 291 242 208 182 162 145 132 121 112 104

44 kW/Hr. NAT 121 Litres

CGL150032 150,000 LP 32 Gal 80

LPH 2752 1836 1378 1102 916 787 689 613 549 500

GPH 727 485 364 291 242 208 182 162 145 132

458

121

424 394

112 104

44 kW/Hr. LP 121 Litres

CGN200032 199,900 NAT 32 Gal

59 kW/Hr. NAT 121 Litres

CGL200032 182,000 LP 32 Gal

53 kW/Hr. LP 121 Litres

80

80

LPH 2752 1836 1378 1102 916 787 689 613 549 500

GPH 969 646 485 388 323 277 242 215 194 176

LPH 3668 2445 1836 1469 1223 1049 916 814 734 666

GPH 882 588 441 353 294 252 221 196 177 160

LPH 3339 2226 1669 1336 1113 954 837 742 670 606

458

162

613

147

557

424 394

149 139

564 526

136 126

515 477

FOREWORD

These designs comply with ANSI Z21.10.3 as a Booster type water heater.

Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and methods of piping necessary. It is highly essential that all water, gas piping and wiring be installed as shown on the diagrams.

Particular attention should be given to the installation of thermometers at the locations indicated on the diagrams as these are necessary for checking the proper functioning of the heater.

These heaters may be installed on combustible floors.

2

In addition to these instructions, the equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.

The installation must conform to these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the latest editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the

National Electrical Code, NFPA 70, documents are available from the National Fire Protection Association, 1 Batterymarch Park,

Quincy, MA 02269.

TABLE OF CONTENTS

Page

ROUGH-IN-DIMENSIONS ......................................................2

FOREWORD ...........................................................................2

GENERAL SAFETY INFORMATION .......................................3

Precautions .........................................................................3

Grounding Instructions ........................................................3

Chemical Vapor Corrosion...................................................3

Improper Combustion ........................................................3-4

Extended Non-Use ..............................................................4

Insulation Blankets ..............................................................4

High Altitude Installation ......................................................4

FEATURES ..............................................................................4

The Eliminator™ (Self-Cleaning System) ..........................4-5

High Limit Switch ................................................................5

Electronic Ignition Control ...................................................5

Exhaust Inducer (Blower Assy.) ...........................................5

Circulating Pump .................................................................5

Dishwashing Machine Requirement ....................................5

INSTALLATION INSTRUCTIONS ...........................................6

Required Ability ...................................................................6

Uncrating .............................................................................6

Locating The Heater ............................................................6

Levelling ..............................................................................6

Clearances ..........................................................................6

Hard Water ..........................................................................6

Air Requirements ...............................................................6-7

Venting ..............................................................................7-8

Multiple Heater Manifold ......................................................8

Water Line Connections ......................................................8

Water (Potable) Heating and Space Heating ......................8

Thermometers (Not Supplied) .............................................8

Relief Valve ..........................................................................8

Gas Piping ...........................................................................9

Purging ................................................................................9

Gas Pressure Regulator ...................................................9-10

Heater Wiring .....................................................................10

GENERAL SAFETY INFORMATION

PRECAUTIONS

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN

UNDER WATER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT

OPERATE HEATER UNTIL ALL CORRECTIVE STEPS HAVE

BEEN MADE BY A QUALIFIED SERVICEMAN.

1. EXTERNAL FIRE.

2. DAMAGE.

3. FIRING WITHOUT WATER.

4. SOOTING

GROUNDING INSTRUCTIONS

This water heater must be grounded in accordance with the

National Electric Code and/or local codes. These must be followed in all cases.

This water heater must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the water heater, see

Figure 9.

Page

INSTALLATION DIAGRAMS .............................................. 11-17

OPERATION ..........................................................................18

General ..............................................................................18

SEQUENCE OF OPERATION ..............................................18

Lighting and Operation ......................................................19

Water Temperature Control ...............................................20

PREVENTIVE MAINTENANCE .............................................20

Check The Ignitor Assembly ..............................................20

Ignitor Assembly ................................................................20

Main Burner .................................................................... 20-21

Gas Valves ........................................................................21

Checking The Input ...........................................................21

Venting System .................................................................21

Remote Storage Tank Temperature Control ......................21

Relief Valve ........................................................................22

Hot Water Odor .................................................................22

Anode Rod Inspection .......................................................22

Flushing .............................................................................22

Draining .............................................................................22

Recommended Procedure For Periodic

Removal of Lime Deposits From Tank Type

Commercial Water Heaters ............................................ 22-23

Deliming Solvents ..............................................................23

Tank Cleanout Procedures ............................................. 23-24

Ignition Module System .....................................................24

System Diagnostics ...........................................................24

SERVICE ...............................................................................24

Electrical Servicing ............................................................24

Replacement Parts ............................................................24

Sequence of Operation Flow Chart ...................................25

Operational Checklist ........................................................26

Limited Warranty ...............................................................27

CHEMICAL VAPOR CORROSION

WARNING

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY

OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN

CHEMICAL VAPORS. SUCH CORROSION MAY RESULT IN

FAILURE AND RISK OF ASPHYXIATION.

Spray can propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool chemicals, calcium and sodium chloride (water softener salt), waxes, and process chemicals and typical compounds which are potentially corrosive.

Do not store products of this sort near the heater. Also, air which is brought in contact with a the heater should not contain any of these chemicals. If necessary, uncontaminated air should be obtained from remote or outside sources. The limited warranty is voided when failure of water heater is due to a corrosive atmosphere. (Refer to the limited warranty for complete terms and conditions.

IMPROPER COMBUSTION

WARNING

ATTIC AND/OR EXHAUST FANS OPERATING ON THE

PREMISES WITH A WATER HEATER CAN RESULT IN CARBON

MONOXIDE POISONING AND DEATH.

3

OPERATION OF THESE FANS CAN PRODUCE A NEGATIVE

DRAFT IN THE AREA OF THE WATER HEATER PREVENTING

THE PRODUCTS OF COMBUSTION FROM EXHAUSTING

THROUGH THE CHIMNEY OR VENT PIPE.

The venting of the water heater should be inspected by a qualified service technician at the time of installation and periodically thereafter to ensure a down-draft condition does not exist.

DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND

VENTILATING AIR. ADEQUATE AIR FOR COMBUSTION AND

VENTILATION MUST BE PROVIDED FOR SAFE OPERATION.

EXTENDED NON-USE PERIODS

WARNING

HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER

SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN

USED FOR A LONG PERIOD OF TIME (GENERALLY TWO

WEEKS OR MORE). HYDROGEN GAS IS EXTREMELY

FLAMMABLE. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow.

THERE SHOULD BE NO SMOKING

OR OPEN FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN.

INSULATION BLANKETS

Insulation blankets available to the general public for external use on gas water heaters are not approved for use on your

Lochinvar water heater. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank water heaters. Your Lochinvar water heater meets or exceeds the the current edition of ASHRAE/IES 90.1 standards with respect to insulation and standby loss requirement making an insulation blanket unnecessary.

WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions. Failure to follow these instructions can result in fire, asphyxiation, serious personal injury or death.

• Do not apply insulation to the top of the water heater, as this will interfere with safe operation of drafthood.

• Do not cover the temperature & pressure relief valve.

• Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

• Do obtain new labels from Lochinvar for placement on the blanket directly over the existing labels.

HIGH ALTITUDE INSTALLATIONS

As elevation above sea level is increased, there is less oxygen per cubic foot of air. Therefore, the heater input rate should be reduced at high altitudes for satisfactory operation with the reduced oxygen supply. Failure to make this reduction would result in an overfiring of the heater causing sooting, poor combustion and/or unsatisfactory heater performance.

REQUIREMENTS

Ratings specified by manufacturers for most appliances apply for elevations up to 2000 feet. For elevations above 2000 feet, ratings must be reduced at the rate of 4% for each 1000 feet above sea level. For example, if a heater is rated at

120,000 Btuh at sea level, to rate the heater at 4000 feet, you subtract 4 (once for each thousand feet) x.04 (4% input reduction) x 120,000 Btuh (original rating) from the original rating. Therefore, to calculate the input rating at 4,000 feet: 4 x .04 x 120,000 =19,200

Btuh, 120,000 - 19,200 = 100,800 Btuh. At 6000 feet the correct input rating should be 91,200 Btuh.

The input reduction is primarily achieved by reducing the size of the main burner orifices. To do this, the main burner orifices require replacement with orifices sized for the particular installation elevation. Correct orifice sizing and parts may be obtained from Lochinvar. When ordering, be sure to state the model number and the altitude of the location where the water heater is being installed.

Upon completion of derating of the heater, adjustment to the gas pressure regulator may be required. See CHECKING

THE INPUT section in this manual for inlet and manifold pressure requirements.

Also due to the input rating reduction required at high altitudes, the output rating of the appliance is also reduced and should be compensated for in the sizing of the equipment for application.

FEATURES

THE ELIMINATOR™

(SELF-CLEANING SYSTEM)

These units include The Eliminator (Self-Cleaning System) installed in the front water inlet, see Figure 2. The Eliminator must be oriented correctly for proper function. There is a marked range on the pipe nipple portion of the Eliminator, that must be aligned with the top of the inlet spud. A label above the jacket hole has an arrow that will point to the marked portion of the pipe nipple if the orientation is correct. If the arrow does not point within the marked range on the pipe nipple, adjust the pipe nipple to correct. A pipe union is supplied with the Eliminator to reduce the probability of misaligning the Eliminator accidentally while tightening the connection to the inlet water supply line. Improper orientation of the Eliminator can cause poor performance of the heater and can significantly reduce outlet water temperatures during heavy draws.

WARNING

INSTALLATIONS ABOVE 2000 FEET (610 METERS) REQUIRE

REPLACEMENT OF THE BURNER ORIFICE IN ACCORDANCE

WITH SECTION 8.1.2 OF THE NATIONAL FUEL GAS CODE

(ANSI Z223.1). FAILURE TO REPLACE THE ORIFICE WILL

RESULT IN IMPROPER AND INEFFICIENT OPERATION

OF THE APPLIANCE RESULTING IN THE PRODUCTION

OF INCREASED LEVELS OF CARBON MONOXIDE GAS

IN EXCESS OF SAFE LIMITS WHICH COULD RESULT IN

SERIOUS PERSONAL INJURY OR DEATH.

You should contact your gas supplier for any specific changes which may be required in your area.

4

Note: The inlet tube may have 1, 3 or 7 cross tubes.

FIGURE 2

For proper function, the Eliminator must be oriented correctly.

There is a marked range on the pipe nipple that must be aligned with the top of the inlet spud (check for label on the appliance) to assure proper operation. Please check to confirm that the marked range is in alignment with the top of the spud. A pipe union is supplied with the Eliminator to help eliminate the

possibility of changing the orientation by accidentally overtightening the inlet supply. Improper orientation of the Eliminator may cause temperature buildup issues or spells of colder than usual water temperatures.

HIGH LIMIT SWITCH

The digital thermostat (see Figure 3) contains the high limit

(energy cutoff) sensor. The high limit switch interrupts main burner gas flow should the water temperature reach

203°F(195°C).

In the event of high limit switch operation, the appliance cannot be restarted unless the water temperature is reduced to approximately

120°F (49°C). The high limit reset button on the front of the control then needs to be depressed.

Continued manual resetting of high limit control, preceded by higher than usual water temperature is evidence of high limit switch operation. The following is a possible reason for high limit switch operation.

A malfunction in the thermostatic controls would allow the gas valve to remain open causing water temperature to exceed the thermostat setting. The water temperature would continue to rise until high limit switch operation.

Contact your dealer or service agent if continued high limit switch operation occurs.

EXHAUST INDUCER (BLOWER ASSEMBLY)

All units are equipped with a exhaust inducer. The inducer assists in drawing in fresh air to the unit for combustion and then assists in dispensing the combustion by-products into the venting leading outside.

The exhaust inducer is equipped with a gravity controlled damper to reduce the amount of heat loss through the flue, improving efficiency.

FIGURE 5 - EXHAUST INDUCER

CIRCULATING PUMP

A circulating pump is used when a system requires a circulating loop or there is a storage tank used in conjunction with the heater.

Refer to the piping diagrams at rear of manual for electrical hookup information and install in accordance with the latest version of the

National Electric Code ANSI/NFPA No. 70.

FIGURE 3 - DIGITAL THERMOSTAT

ELECTRONIC IGNITION CONTROL

Each heater is equipped with a ignition module. The solid state ignition control (see Figure 4), ignites the main burner by utilizing a silicone nitride ignitor. The silicone nitride ignitor shuts off during the heating cycle and the main burner flame is sensed through a remote flame sensor integral to the silicone nitride ignitor assembly.

The ignition control will try to ignite the main burner three times before lockout. Then it waits one hour before trying again to ignite the main burners. This is a continuous cycle.

Only all bronze circulators are used with commercial water heaters.

Although circulators are oiled and operated by the manufacturer some circulators must be oiled again before operating. Please refer to manufacturer’s instructions.

DISHWASHING MACHINE REQUIREMENT

These appliances meet the National Sanitation Foundation

Standard for sanitary installations when used with the following leg kit part number 9003425205.

FIGURE 4 - IGNITION CONTROL BOARD

All dishwashing machines meeting the National Sanitation

Foundation requirements are designed to operate with water flow pressures between 15 and 25 psi. Flow pressures above

25 psi, or below 15 psi, will result in improperly sanitized dishes.

Where pressures are high, a water pressure reducing or flow regulating control valve should be used in 180°F (82°C) line to the dishwashing machine, and should be adjusted to deliver water between these limits.

The National Sanitation Foundation also recommends circulation of 180°F (82°C) water. Where this is done, the circulation should be very gentle so that it does not cause any unnecessary turbulence inside the water heater. The circulation should be just enough to provide 180°F (82°C) water at the point of take-off to the dishwashing machine. Adjust flow by means of the plug cock in the circulating line.

5

INSTALLATION INSTRUCTIONS

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER

REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED

TRADESMAN IN THE FIELD INVOLVED. PLUMBING, AIR SUPPLY,

VENTING, GAS SUPPLY AND ELECTRICAL WORK ARE REQUIRED.

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT

IN SERIOUS PERSONAL INJURY OR DEATH.

UNCRATING

The heater is shipped with the inducer already installed. The wiring conduit runs from the thermostat to the inducer. Before turning unit on, check to make sure wiring conduit is securely plugged into the inducer.

LOCATING THE HEATER

LEVELING

If the unit is not level, insert the bolts which were used in crating into the legs to correct this condition.

CLEARANCES

These heaters are approved for installation on combustible flooring in an alcove when the minimum clearance from any combustion construction are followed as indicated in figure 6.

In all installations the minimum combustible clearances from vent piping shall be 6”. Vent piping passing through a combustible wall or ceiling must be a continuous run (no joints) and retain the 6” clearance unless an approved reducing thimble is used.

A service clearance of 24” should be maintained from serviceable parts, such as relief valves, flue baffles, thermostats, cleanout openings or drain valves.

The units are approved for installation with side, rear and ceiling clearances.

HARD WATER

Where hard water conditions exist, water softening or threshold type of water treatment is recommended. This will protect dishwashers, coffee urns, water heaters, water piping and other equipment.

See MAINTENANCE section for details of tank cleanout procedure.

WARNING

THERE IS A RISK IN USING FUEL BURNING APPLIANCES SUCH

AS GAS WATER HEATERS IN ROOMS, GARAGES OR OTHER

AREAS WHERE GASOLINE, OTHER FLAMMABLE LIQUIDS OR

ENGINE DRIVEN EQUIPMENT OR VEHICLES ARE STORED,

OPERATED OR REPAIRED. FLAMMABLE VAPORS ARE HEAVY

AND TRAVEL ALONG THE FLOOR AND MAY BE IGNITED BY THE

HEATER’S PILOT OR MAIN BURNER FLAMES CAUSING FIRE

OR EXPLOSION. SOME LOCAL CODES PERMIT OPERATION OF

GAS APPLIANCES IN SUCH AREAS IF THEY ARE INSTALLED

18” OR MORE ABOVE THE FLOOR. THIS MAY REDUCE THE

RISK IF LOCATION IN SUCH AN AREA CANNOT BE AVOIDED.

DO NOT INSTALL THIS WATER HEATER DIRECTLY ON A

CARPETED FLOOR. A FIRE HAZARD MAY RESULT. Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches in any direction.

If the heater is installed in a carpeted alcove, the entire floor shall be covered by the panel. Also, see the DRAINING requirements in MAINTENANCE Section.

THE HEATER SHALL BE LOCATED OR PROTECTED SO IT IS

NOT SUBJECT TO PHYSICAL DAMAGE BY A MOVING VEHICLE.

WARNING

FLAMMABLE ITEMS, PRESSURIZED CONTAINERS OR ANY

OTHER POTENTIAL FIRE HAZARDOUS ARTICLES MUST

NEVER BE PLACED ON OR ADJACENT TO THE HEATER. OPEN

CONTAINERS OR FLAMMABLE MATERIAL SHOULD NOT BE

STORED OR USED IN THE SAME ROOM WITH THE HEATER.

When installing the heater, consideration must be given to proper location. Location selected should be as close to the stack or chimney as practicable, with adequate air supply and as centralized with the piping system as possible.

CLOSED WATER SYSTEMS

Water supply systems may, because of code requirements or such conditions as high line pressure, among others, have installed devices such as pressure reducing valves, check valves, and back flow preventers. Devices such as these cause the water system to be a closed system.

THERMAL EXPANSION

As water is heated, it expands (thermal expansion). In a closed system the volume of water will grow when it is heated. As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent Temperature-Pressure Relief Valve operation: water discharged from the valve due to excessive pressure build up. This condition is not covered under the limited warranty. The Temperature-Pressure Relief Valve is not intended for the constant relief of thermal expansion.

A properly sized thermal expansion tank must be installed on all closed systems to control the harmful effects of thermal expansion. Contact a local plumbing service agency to have a thermal expansion tank installed.

THE HEATER MUST NOT BE LOCATED IN AN AREA WHERE

IT WILL BE SUBJECT TO FREEZING.

LOCATE IT NEAR A FLOOR DRAIN. THE HEATER SHOULD BE

LOCATED IN AN AREA WHERE LEAKAGE FROM THE HEATER

OR CONNECTIONS WILL NOT RESULT IN DAMAGE TO THE

ADJACENT AREA OR TO LOWER FLOORS OF THE STRUCTURE.

WHEN SUCH LOCATIONS CANNOT BE AVOIDED, A SUITABLE

DRAIN PAN SHOULD BE INSTALLED UNDER THE HEATER.

Such pans should be fabricated with sides at least 2” deep, with length and width at least 2” greater than the diameter of the heater and must be piped to an adequate drain. The pan must not restrict combustion air flow.

For appliance installation locations with elevations above

2000 feet (610m), refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure.

6

AIR REQUIREMENTS

REFER TO THE LATEST EDITION OF THE “NATIONAL FUEL

GAS CODE” ANSI Z223.1/NFPA 54.

KEEP APPLIANCE AREA CLEAR AND FREE OF COMBUSTIBLE

MATERIALS, GASOLINE AND OTHER FLAMMABLES,

VAPORS AND LIQUIDS.

DO NOT OBSTRUCT THE FLOW OF COMBUSTION OR

VENTILATING AIR.

WARNING

FOR SAFE OPERATION PROVIDE ADEQUATE AIR FOR

COMBUSTION AND VENTILATION. AN INSUFFICIENT SUPPLY

OF AIR WILL CAUSE RECIRCULATION OF COMBUSTION

PRODUCTS RESULTING IN AIR CONTAMINATION THAT

MAY BE HAZARDOUS TO LIFE. SUCH A CONDITION OFTEN

WILL RESULT IN A YELLOW, LUMINOUS BURNER FLAME,

FIGURE 6 - ILLUSTRATION OF MINIMUM COMBUSTIBLE CLEARANCES IN AN ALCOVE

CAUSING CARBONING OR SOOTING OF THE COMBUSTION

CHAMBER, BURNERS AND FLUE TUBES AND CREATES A

RISK OF ASPHYXIATION.

Remove all soot or other obstructions from the chimney that will retard a free draft.

Type B venting is recommended with these heaters.

Where an exhaust fan is supplied in the same room with a heater, sufficient openings for air must be provided in the walls.

UNDERSIZED OPENINGS WILL CAUSE AIR TO BE DRAWN

INTO THE ROOM THROUGH THE CHIMNEY, CAUSING POOR

COMBUSTION. SOOTING MAY RESULT IN SERIOUS DAMAGE

TO THE HEATER AND RISK OF FIRE OR EXPLOSION.

This water heater must be vented in compliance with all local codes, the current revision of the National Fuel Gas Code

(ANSI-Z223.1) and with the Category I Venting Tables.

If any part of the vent system are exposed to ambient temperatures below 40°F (4°C) it must be insulated to prevent condensation.

UNCONFINED SPACE

In buildings of conventional frame, brick, or stone construction, unconfined spaces may provide adequate air for combustion, ventilation and draft hood dilution.

The following steps shall be followed with each appliance connected to the venting system placed in operation, while any other appliances connected to the venting system are not in operation.

If the unconfined space is within a building of tight construction

(buildings using the following construction: weather stripping, heavy insulation, caulking, vapor barrier, etc.), air for combustion, ventilation and draft hood dilution must be obtained from outdoors.

The installation instructions for confined spaces in tightly constructed buildings must be followed to ensure adequate air supply.

CONFINED SPACE

When drawing combustion and dilution air from inside a conventionally constructed building to a confined space, such a space shall be provided with two permanent openings, ONE IN

OR WITHIN 12 INCHES OF THE ENCLOSURE TOP AND ONE

IN OR WITHIN 12 INCHES OF THE ENCLOSURE BOTTOM.

Each opening shall have a free area of at least one square inch per 1000 Btuh of the total input of all appliances in the enclosure, but not less than 100 square inches.

If the confined space is within a building of tight construction, air for combustion, ventilation, must be obtained from outdoors.

When directly communicating with the outdoors or communicating with the outdoors through vertical ducts, two permanent openings, located in the above manner, shall be provided.

Each opening shall have a free area of not less than one square inch per 4000 Btuh of the total input of all appliances in the enclosure. If horizontal ducts are used, each opening shall have a free area of not less than one square inch per

2000 Btuh of the total input of all appliances in the enclosure.

1. Seal any unused openings in the venting system.

2. Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1.

Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition.

3. So far as is practical, close all building doors and windows and all doors between the space in which the water heater(s) connected to the venting system are located and other spaces of the building. Turn on all appliances not connected to the venting system. Turn on all exhaust fans, such as range hoods and bathroom exhausts, so they shall operate at maximum speed. Close fireplace dampers.

4. Follow the lighting instruction. Place the water heater being inspected in operation. Adjust thermostat so appliance shall operate continuously.

5. After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous conditions of use.

6. If improper venting is observed during any of the above tests, the venting system must be corrected.

WARNING

FAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIR

CONTAMINATION AND UNSAFE CONDITIONS.

VENTING

WARNING

THE INSTRUCTIONS IN THIS SECTION ON VENTING MUST

BE FOLLOWED TO AVOID CHOKED COMBUSTION OR

RECIRCULATION OF FLUE GASES. SUCH CONDITIONS

CAUSE SOOTING OR RISKS OF FIRE AND ASPHYXIATION.

Heater must be protected from freezing downdrafts.

• If the back draft cannot be corrected by the normal method or if a suitable draft cannot be obtained, a blower type flue gas exhauster must be employed to assure proper venting and correct combustion.

• Do not connect the heater to a common vent or chimney with solid fuel burning equipment. This practice is prohibited by many local building codes as is the practice of venting gas fired equipment to the duct work of ventilation systems.

7

FIGURE 7

• Where a separate vent connection is not available and the vent pipe from the heater must be connected to a common vent with an oil burning furnace, the vent pipe should enter the smaller common vent or chimney at a point above the large vent pipe.

MULTIPLE HEATER MANIFOLD

When horizontally manifolding two or more heaters vent as shown in Figure 8. Refer to NFPA 54/ANSI Z223.1 for venting multiple heaters.

CAUTION

A closed system will exist if a check valve (without bypass), pressure reducing valve (without bypass), or a water meter

(without bypass) is installed in the cold water line between the water heater and street main (or well).

Excessive pressure may develop in such closed systems, causing premature tank failure or intermittent relief valve operation. This is not a warranty failure. An expansion tank or a similar device may be required in the inlet supply line between the appliance and the meter or valve to compensate for the thermal expansion of the water.

SYSTEM CONNECTIONS

The system installation must conform to these instructions and to the local code authority having jurisdiction. Good practice requires that all heavy piping be supported.

THERMOMETERS (Not Supplied)

Thermometers should be obtained and field installed as shown in the installation diagrams.

Thermometers are installed in the system as a means of detecting the temperature of the outlet water supply.

FIGURE 8

WATER LINE CONNECTIONS

This manual provides detailed installation diagrams (see pages

12 thru 17 of this manual) for typical methods of application for the water heaters.

RELIEF VALVE

This water heater is equipped with a combination temperature-pressure relief valve that complies with the standard for relief valves and automatic gas shutoff devices for hot water supply system, ANSI Z21.22.

FOR SAFE OPERATION OF

THE WATER HEATER, THE RELIEF VALVE(S) MUST NOT BE

REMOVED OR PLUGGED.

ASME ratings cover pressure relief capacities. CSA ratings cover release rate with temperature actuation.

The water heater may be installed by itself, or with a separate storage tank, on both single and two-temperature systems. When used with a separate storage tank, the circulation may be either by gravity or by means of a circulating pump. When a circulating pump is used it is important to note that the flow rate should be slow so that there will be a minimum of turbulence inside the heater.

If a water heater is installed in a closed water system, contact the water supplier or local plumbing inspector on how to control this situation.

WATER (POTABLE) HEATING

AND SPACE HEATING

1. All piping components connected to this unit for space heating

applications shall be suitable for use with potable water.

2. Toxic chemicals, such as those used for boiler treatment, shall

NEVER be introduced into this system.

3. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable

water heating appliance.

4. When the system requires water for space heating at temperatures higher than required for domestic water purposes, a tempering valve must be installed. Please refer to installation diagrams on pages 12 thru 17 of this manual for suggested piping arrangements.

5. These water heaters cannot be used in space heating applications only.

8

In addition to the appliance relief valve, each remote storage tank which may be used in conjunction with this appliance shall also be installed with a properly sized, rated and approved combination temperature (ANSI) and pressure (ASME) relief valve(s).

WARNING

THE PURPOSE OF RELIEF VALVE IS TO AVOID EXCESSIVE

PRESSURE OR TEMPERATURE INTO THE STEAM RANGE,

WHICH MAY CAUSE SCALDING AT FIXTURES, TANK

EXPLOSION, SYSTEM OR HEATER DAMAGE. NO VALVE IS

TO BE PLACED BETWEEN THE RELIEF VALVE AND TANK.

Your local code authority may have other specific relief valve requirements.

A DRAIN LINE MUST BE CONNECTED TO THE RELIEF VALVE

TO DIRECT DISCHARGE TO A SAFE LOCATION TO AVOID

SCALDING OR WATER DAMAGE. THIS LINE MUST NOT BE

REDUCED FROM THE SIZE OF THE VALVE OUTLET AND

MUST NOT CONTAIN VALVES, RESTRICTIONS NOR SHOULD

IT BE LOCATED IN FREEZING AREAS. DO NOT THREAD OR

CAP THE END OF THIS LINE. RESTRICTED OR BLOCKED

DISCHARGE WILL DEFEAT THE PURPOSE OF THE VALVE

AND IS UNSAFE. DISCHARGE LINE SHALL BE INSTALLED TO

ALLOW COMPLETE DRAINAGE OF BOTH THE VALVE AND LINE.

See SERVICE INFORMATION section for procedure and precautions.

GAS PIPING

Contact your local gas service company to ensure that adequate gas service is available and to review applicable installation codes for your area.

Size the main gas line in accordance with Table 2. The figures shown are for straight lengths of pipe at 0.5 in. W.C. pressure drop, which is considered normal for low pressure systems. Note:

Fittings such as elbows, tees and line regulators will add to the pipe pressure drop. Also refer to the latest version of the National

Fuel Gas Code.

WARNING

THE HEATER IS NOT INTENDED FOR OPERATION AT

HIGHER THAN 14.0” W.C.(3.48 kPa) - NATURAL GAS, 14.0”

W.C.(3.48kPa) EXPOSURE TO HIGHER SUPPLY PRESSURE

MAY CAUSE DAMAGE TO THE GAS VALVE WHICH COULD

RESULT IN FIRE OR EXPLOSION. IF OVERPRESSURE HAS

OCCURRED SUCH AS THROUGH IMPROPER TESTING OF

GAS LINES OR EMERGENCY MALFUNCTION OF THE SUPPLY

SYSTEM, THE GAS VALVE MUST BE CHECKED FOR SAFE

OPERATION. MAKE SURE THAT THE OUTSIDE VENTS ON

THE SUPPLY REGULATORS AND THE SAFETY VENT VALVES

ARE PROTECTED AGAINST BLOCKAGE. THESE ARE PARTS

OF THE GAS SUPPLY SYSTEM, NOT THE HEATER. VENT

BLOCKAGE MAY OCCUR DURING ICE STORMS.

TABLE 2 - GAS SUPPLY LINE SIZES (IN INCHES)*

MAXIMUM CAPACITY OF PIPE IN CUBIC FEET PER HOUR

(Based upon a Pressure Drop of 0.5 inch Water Column and

0.6 specific Gravity Gas and max. gas pressure of 0.5 psig)

LENGTH NOMINAL IRON PIPE SIZES (INCHES)

IN FEET 1/2” 3/4” 1” 1 1/4” 1 1/2” 2” 2 1/2” 3”

4”

10 175 360 680 1400 2100 3960 6300 11000 23000

20 120 250 465 950 1460 2750 4360 7700 15800

30 97 200 375 770 1180 2200 3520 6250 12800

82 170 320 660 990 1900 3000 5300 10900 40

50

60

70

80

90

100

125

150

175

200

73 151 285 580

66 138 260 530

61 125 240 490

57 118 220 460

53 110 205 430

50 103 195 400

44

40

37

35

93 175 360

84 160 325

77 145 300

72 135 280

900 1680 2650 4750 9700

810 1520 2400 4300 8800

750 1400 2250 3900 8100

690 1300 2050 3700 7500

650 1220 1950 3450 7200

620 1150 1850 3250 6700

550 1020 1650 2950 6000

500 950 1500 2650 5500

460 850 1370 2450 5000

430 800 1280 2280 4600

IT IS IMPORTANT TO GUARD AGAINST GAS VALVE FOULING

FROM CONTAMINANTS IN THE GAS WAYS. SUCH FOULING

MAY CAUSE IMPROPER OPERATION, FIRE OR EXPLOSION.

IF COPPER SUPPLY LINES ARE USED THEY MUST BE

INTERNALLY TINNED AND CERTIFIED FOR GAS SERVICE.

BEFORE ATTACHING THE GAS LINE, BE SURE THAT ALL

GAS PIPE IS CLEAN ON THE INSIDE.

TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS

SUPPLY LINE, A DIRT LEG (SOMETIMES CALLED SEDIMENT

TRAP OR DRIP LEG) MUST BE INCORPORATED IN THE PIPING

(SEE FIG. 9). THE DIRT LEG MUST BE READILY ACCESSIBLE

AND NOT SUBJECT TO FREEZING CONDITIONS. INSTALL

IN ACCORDANCE WITH RECOMMENDATIONS OF SERVING

GAS SUPPLIERS. REFER TO THE LATEST VERSION OF THE

NATIONAL FUEL GAS CODE.

To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to gas valve inlet.

Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compounds to the first two threads. Use compounds resistant to the action of liquefied petroleum gases.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR

GAS LEAKAGE.

Use soap and water solution or other material acceptable for the purpose in locating the leaks.

DO NOT USE

MATCHES, CANDLES, FLAME OR OTHER SOURCES OF

IGNITION FOR THIS PURPOSE.

DISCONNECT THE HEATER AND ITS MANUAL GAS SHUTOFF

VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURING

ANY SUPPLY PRESSURE TESTING EXCEEDING 1/2 PSIG.

GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED

FROM THE HEATER FOR TEST PRESSURES OF 1/2 PSIG OR

LESS. THE APPLIANCE NEED NOT BE DISCONNECTED, BUT

MUST BE ISOLATED FROM THE SUPPLY PRESSURE TEST

BY CLOSING THE MANUAL GAS SHUTOFF VALVE.

GAS PIPING AND DIRT LEG INSTALLATION

FIGURE 9

PURGING

Gas line purging is required with new piping or systems in which air has entered.

CAUTION

PURGING SHOULD BE PERFORMED BY PERSONS

EXPERIENCED IN THIS TYPE GAS SERVICE. TO AVOID RISK

OF FIRE OR EXPLOSION, PURGE DISCHARGE MUST NOT

ENTER CONFINED AREAS OR SPACES WHERE IGNITION CAN

OCCUR. THE AREA MUST BE WELL VENTILATED AND ALL

SOURCES OF IGNITION MUST BE INACTIVATED OR REMOVED.

GAS METER SIZE — NATURAL GASES ONLY

Be sure the gas meter has sufficient capacity to supply the full rated gas input of the water heater as well as the requirements of all other gas fired equipment supplied by the meter. If gas meter is too small, ask the gas company to install a larger meter having adequate capacity.

GAS PRESSURE REGULATOR

The gas pressure regulator is built into the gas valve and is equipped to operate on the gas specified on model and rating plate. The regulator is factory adjusted to deliver gas to burner at correct water column pressure allowing for a nominal pressure drop through the controls.

The minimum gas supply pressure for input adjustment must not be less than 4.5” w.c. for natural gas.

9

Do not subject the combination gas valve to inlet gas pressures of more than 14.0” W.C. - natural gas. A service regulator is necessary if higher gas pressures are encountered.

Manifold gas pressure in inches of water column is 3.5.

The gas pressure specified refers to flow pressure taken at pressure tap of automatic gas valve while heater is operating.

must conform to all local code authority having jurisdiction.

AN

ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF

ELECTRICAL SHOCK OR POSSIBLE ELECTROCUTION.

If any of the original wire as supplied with the appliance must be replaced, use only type 105

0

C thermoplastic or equivalent. 250 ignition cable must be high voltage 250

0

C.

0

C type F must be used for the flame sensor leads and the spark

HEATER WIRING

All electrical work must be installed in accordance with the latest version of the National Electrical Code ANSI/NFPA No. 70,

Figures shown are valid for 0-2000 ft. installations. See

“HIGH ALTITUDE INSTALLATIONS” for deration requirements over 2000 ft.

FIGURE 10 - SINGLE UNIT WIRING DIAGRAM

10

INSTALLATION DIAGRAMS

GENERAL

is installed on the heater. The locations shown in the installation diagrams on the following pages are typical.

The type, size and location of the relief valves must be in accordance with local codes. The locations of the relief valves shown in the installation diagrams are typical. The heater has a factory installed high temperature limit switch and temperature and pressure relief valve.

The discharge opening of the temperature and pressure relief valve, located in front of the heater must be piped to an open drain and should not be subject to freezing temperatures.

Install in accordance with all local codes.

Cold water lines to heater should be installed as shown in order to minimize gravity circulation of hot water to building cold water lines.

A listed temperature and pressure relief valve of adequate capacity

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE

TEMPERATURE AT FIXTURES. SEE WATER TEMPERATURE

CONTROL WARNING ON PAGE 20. IF HIGHER PREHEAT

TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE

BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE FOR HOT

WATER SUPPLIED TO FIXTURES.

11

VERTICAL STORAGE TANK AND FORCED CIRCULATION

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES.

SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 20. IF HIGHER PREHEAT

TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN

ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

HORIZONTAL STORAGE TANK AND FORCED CIRCULATION

12

TWO TEMPERATURE - ONE HEATER HIGH TEMPERATURE STORAGE

WITH RECIRCULATION OF SANITIZING LOOP

NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C) WATER

CIRCULATION. INSTALL ON OR CLOSE TO DISHWASHING

MACHINE. TOGGLE SWITCH MUST BE CLOSED (ON)

DURING THE RINSE OPERATION AND OPEN (OFF) WHEN

DISHWASHER IS NOT OPERATING OR WHEN ON LONG

STANDBY.

NOTE 2: INSTALL LINE TEMPERATURE CONTROL IN AN

UNINSULATED TEE BEYOND THE DISHWASHING MACHINE

TAKEOFF IN THE SANITIZING LOOP. CONTROL SHOULD

BE SET AT 185°F (85°C).

NOTE 3: ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW

RATE DOES NOT CAUSE UNNECESSARY TURBULENCE

IN THE TANK.

* TEMPERED WATER LOOP, IF USED, CONNECT TO

POINT “A”.

**PIPE RELIEF VALVE TO OPEN DRAIN.

INSTALL IN ACCORDANCE WITH LOCAL CODES.

CAUTION: IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW

PREVENTER, CHECK VALVE OR WATER METER WITH CHECK

VALVE. PROVISIONS FOR THERMAL EXPANSION OF WATER

IN THE HOT WATER SYSTEM MUST BE PROVIDED.

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE

TEMPERATURE AT FIXTURES. SEE WATER TEMPERATURE CONTROL

WARNING ON PAGE 20. IF HIGHER PREHEAT TEMPERATURES ARE

NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN

ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

13

INSTALLATION DIAGRAMS-SIDE INLET/OUTLET USAGE

A listed temperature and pressure relief valve of adequate capacity is installed on the heater. The locations shown in the installation diagrams on the following pages are typical.

The discharge opening of the temperature and pressure relief valve must be piped to an open drain and should not be subject to freezing conditions. DO NOT REDUCE, BLOCK OR PLUG

THE DISCHARGE OPENING OF THE VALVE.

TWO TEMPERATURE - TWO HEATERS,

ONE PRE-HEATER/ONE - BOOSTER

HEATER

WITH OR WITHOUT BUILDING RECIRCULATION

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE

TEMPERATURE AT FIXTURES. SEE WATER TEMPERATURE CONTROL

WARNING ON PAGE 20. IF HIGHER PREHEAT TEMPERATURES ARE

NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN

ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

CIRCULATING RETURN LINE CONNECTION

- FROM FIXTURE LOOP, IF USED, CONNECT

TO PRE-HEATER INLET.

- FROM BOOSTED TEMPERATURE LOOP, IF

USED CONNECT TO BOOSTER INLET.

† AVAILABLE FROM LOCHINVAR.

* PIPE RELIEF VALVE TO OPEN DRAIN.

INSTALL IN ACCORDANCE WITH LOCAL CODES.

14

ONE OR TWO TEMPERATURE - ONE HEATERS,HIGH TEMPERATURE

STORAGE WITH OR WITHOUT RECIRCULATION

HEATER WITH OR WITHOUT MIXING VALVE

DANGER

TEMPERATURE SETTING SHOULD NOT

EXCEED SAFE USE TEMPERATURE AT

FIXTURES. SEE WATER TEMPERATURE

CONTROL WARNING ON PAGE 20. IF HIGHER

PREHEAT TEMPERATURES ARE NECESSARY

TO OBTAIN ADEQUATE BOOSTER OUTPUT,

ADD AN ANTI-SCALD VALVE FOR HOT

WATER SUPPLIED TO FIXTURES.

HEATER WITH MIXING VALVE AND RECIRCULATED SANITIZING LOOP

* PIPE RELIEF VALVE TO OPEN DRAIN.

NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C)

WATER CIRCULATION. INSTALL ON OR

INSTALL IN ACCORDANCE WITH LOCAL CODES.

CLOSE TO DISHWASHING MACHINE. TOGGLE

SWITCH MUST BE CLOSED (ON) DURING THE

CIRCULATING RETURN LINE CONNECTIONS.

RINSE OPERATION AND OPEN (OFF) WHEN

DISHWASHER IS NOT OPERATING OR WHEN

ON LONG STANDBY.

- TEMPERED WATER LOOP, IF USED,

CONNECT TO POINT “R”.

- STORED TEMPERATURE WATER LOOP, IF

USED, CONNECT TO COLD WATER INLET.

NOTE 2: INSTALL LINE TEMPERATURE CONTROL

IN AN UNINSULATED TEE BEYOND THE

DISHWASHING MACHINE TAKEOFF

IN THE SANITIZING LOOP. CONTROL

SHOULD BE SET AT 185°F (85°C).

NOTE 3: ADJUST PLUG COCK SO THE SANITIZING

LOOP FLOW RATE DOES NOT CAUSE

UNNECESSARY TURBULENCE IN THE

TANK.

CAUTION: IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW

PREVENTER, CHECK VALVE OR WATER METER WITH CHECK VALVE.

PROVISIONS FOR THERMAL EXPANSION OF WATER IN THE HOT WATER

SYSTEM MUST BE PROVIDED.

15

TWO TEMPERATURE - TWO PRE-HEATERS WITH MIXING VALVE OR BOOSTER HEATER

WITH OR WITHOUT BUILING RECIRCULATION

TWO PRE-HEATERS WITH MIXING VALVE

DANGER

TEMPERATURE SETTING SHOULD NOT

EXCEED SAFE USE TEMPERATURE AT

FIXTURES. SEE WATER TEMPERATURE

CONTROL WARNING ON PAGE 20. IF

HIGHER PREHEAT TEMPERATURES ARE

NECESSARY TO OBTAIN ADEQUATE

BOOSTER OUTPUT, ADD AN ANTI-SCALD

VALVE FOR HOT WATER SUPPLIED TO

FIXTURES.

TWO PRE-HEATERS WITH BOOSTER HEATER

16

MEDIUM TEMPERATURE - ONE HEATER WITH AUXILIARY STORAGE TANK FORCED

CIRCULATION WITH OR WITHOUT BUILDING RECIRCULATION

VERTICAL STORAGE TANK

* PIPE RELIEF VALVE TO OPEN DRAIN.

**WHEN USING AN LOCHINVAR T-140, -200,

-350 OR -400 STORAGE TANK, USE

LOWER 3/4” OPENING FOR TANK

TEMPERATURE CONTROL.

IF BUILDING CIRCULATING LOOP IS USED,

CONNECT TO AN OPENING NEAR THE

BOTTOM OF THE TANK.

HORIZONTAL STORAGE TANK

CAUTION: IF BUILDING COLD WATER SUPPLY HAS A

BACKFLOW PREVENTER, CHECK VALVE OR WATER

METER WITH CHECK VALVE. PROVISIONS FOR

THERMAL EXPANSION OF WATER IN THE HOT WATER

SYSTEM MUST BE PROVIDED.

*PIPE RELIEF VALVE TO OPEN DRAIN

INSTALL IN ACCORDANCE WITH LOCAL CODES.

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED

SAFE USE TEMPERATURE AT FIXTURES. SEE

WATER TEMPERATURE CONTROL WARNING ON

PAGE 20. IF HIGHER PREHEAT TEMPERATURES

ARE NECESSARY TO OBTAIN ADEQUATE

BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE

FOR HOT WATER SUPPLIED TO FIXTURES.

17

OPERATION

IMPORTANT

A qualified person must perform the initial firing of the heater. At this time the user should not hesitate to ask the individual any questions which they may have in regard to the operation and maintenance of the unit.

into lockout. After the controller tries three times, it will wait one hour before trying to light the unit again. This cycle will continue until the main burners are ignited or the unit is shut down.

ADJUSTMENTS

ON INITIAL STARTUP SOME ADJUSTMENTS ARE NECESSARY.

1. CHECK MANIFOLD AND INLET GAS PRESSURES.

An Operational Checklist is included at the rear of this manual. By using this checklist the user may be able to make minor operational adjustments and avoid unnecessary service calls. However, the user should not attempt repairs which are not listed under the

USER column.

2. CYCLE CHECK - CHECK AT LEAST ONE BURNER

OPERATION - WHEN THERMOSTAT IS SATISFIED,

BURNER WILL SHUT OFF AND INDUCER WILL STOP

RUNNING. ON CALL FOR HEAT - THE INDUCER WILL

COME ON AND CLOSE THE PRESSURE SWITCH AND

THE IGNITION SEQUENCE DESCRIBED ABOVE WILL

BEGIN, SEE “SEQUENCE OF OPERATION”.

GENERAL

NEVER OPERATE THE HEATER WITHOUT FIRST BEING

CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE

AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF

VALVE OPENING OF THE HEATER.

SEQUENCE OF OPERATION

The following information will describe the Sequence of Operation for this appliance.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL

TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE

TO THE APPLIANCE.

to escape.

and piping to be filled.

CAUTION

Before proceeding with the operation of the unit make sure the water heater and system are filled with water and all air is expelled.

FILLING

1. Close the heater drain valve by turning handle clockwise.

2. Open a nearby hot water faucet to permit the air in the system

3. Fully open the cold water inlet pipe valve allowing the heater

4. Close the hot water faucet as water starts to flow.

5. The heater is ready to be operated.

WARNING

THE GAS VALVE MUST HAVE BEEN IN THE OFF POSITION

FOR AT LEAST 5 MINUTES. This waiting period is an important safety step. Its purpose is to permit gas that may have accumulated in the combustion chamber to clear. IF YOU

DETECT GAS ODOR AT THE END OF THIS PERIOD DO NOT

PROCEED WITH LIGHTING. RECOGNIZE THAT GAS EVEN IF IT

SEEMS WEAK, MAY INDICATE PRESENCE OF ACCUMULATED

GAS SOMEPLACE IN THE AREA WITH RISK OF FIRE OR

EXPLOSION. SEE THE FRONT PAGE FOR STEPS TO BE TAKEN.

All gas and water lines leak tested and open.

Read

SEQUENCE OF OPERATION

section of this manual prior to lighting and operating this appliance.

With above conditions satisfied, start the unit in accordance with the instructions on the Operating label attached to the heater. If label instructions are not legible - determine which gas valve the appliance is equipped with and use the applicable

INSTRUCTIONS as follows:

OPERATING

Each heater is equipped with an ignition control board. The controller will try three times to light the main burner before going

18

1. Switch power on to unit.

2. Thermostat calls for heat.

3. Ignition Control Board performs diagnostic check on system components.

4. On completion of diagnostics check, the Ignition Control Board sends signal to Exhaust Inducer.

5. Exhaust Inducer begins drawing air through appliance closing the Prover Switch.

6. On completion of Prover Switch engagement, the Ignition

Control Board begins the ignition cycle.

7. The Ignition Control Board provides power to the Silicon

Nitride Ignitor.

8. The Silicon Nitride Ignitor heats up for approximately 17 to

20 seconds.

9. At the end of Silicon Nitride Ignitor’s warm-up, the Ignition

Control Board opens the Gas Valve.

10. From the time the Gas Valve opens, the Ignition Control Board waits 3 seconds and then shuts off power to the Silicon Nitride

Ignitor.

11. From the time the Silicon Nitride Ignitor’s power is shut off, the Ignition Control Board waits 3 more seconds to monitor the Flame Sensor.

12. If the Flame Sensor does not detect a strong enough flame, the Ignition Control Board shuts off the Gas Valve and allows the Exhaust Inducer to purge the unit for 20 seconds. At that time, the Ignition Control Board restarts with step 7. It will try and ignite the main burners 2 more times. If the unit does not light, the Ignition Control Board will wait one hour and then restart at step 3. This cycle will continue until the unit lights or the power is shutoff to the unit.

13. If the Flame Sensor detects a strong flame, the Ignition Control

Board will allow the unit to operate until the thermostat is satisfied.

14. Once the unit is satisfied, the Ignition Control Board will shut off the Gas Valve and the unit will be in standby mode until another call for heat is initiated by the thermostat.

See the flow chart on page 25 for more information.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner.

Do not try to light the burner by hand.

B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

“WHAT TO DO IF YOU SMELL GAS”

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any telephone in your building.

• Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1. STOP! Read the safety information above on this

label.

2. Set thermostat to lowest setting.

3. Turn off all electric power to the appliance.

4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

5. Push in gas control knob slightly and turn clockwise

to “OFF”.

6. Wait five (5) minutes to clear out any gas. If you

then smell gas, safety information

STOP! Follow “B” in the

above on this label. If you don’t smell gas, go on to the next step.

7. Turn gas control knob counterclockwise

8. Turn on all electric power to the appliance.

to “ON”.

9. Set thermostat to desired setting.

10. If the appliance will not operate, follow the instructions

“To Turn Off Gas To Appliance” and call your service technician or gas supplier.

FOR YOUR SAFETY READ BEFORE OPERATING

1. Set the thermostat to lowest setting.

2. Turn off all electric power to appliance if service is to be performed.

3. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force.

19

WATER TEMPERATURE CONTROL

be set for 120° to 180°F water temperature, but 120°F is the recommended starting point. It is suggested the dial be placed on the lowest setting which produces an acceptable hot water supply. This will always give the most energy efficient operation.

The temperature control has a 4°F (2°C) fixed differential.

PREVENTIVE MAINTENANCE

CHECK THE IGNITOR ASSEMBLY

At least once a year, check the ignitor assembly, see Figure 11, and the main burner, see Figure 12, for proper operation. Refer to the following ignitor assembly and main burner sections.

DANGER

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE

THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT

WATER TEMPERATURES REQUIRED FOR AUTOMATIC

DISHWASHER AND LAUNDRY USE CAN CAUSE SCALD BURNS

RESULTING IN SERIOUS PERSONAL INJURY AND/OR DEATH.

THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH

THE PERSON’S AGE AND TIME OF EXPOSURE. THE SLOWER

RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS

INCREASES THE HAZARDS TO THEM. NEVER ALLOW SMALL

CHILDREN TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN

BATH WATER. NEVER LEAVE A CHILD OR DISABLED PERSON

UNATTENDED IN A BATHTUB OR SHOWER.

THE WATER HEATER SHOULD BE LOCATED IN AN AREA

WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS

TO SET TEMPERATURES.

SETTING THE WATER HEATER TEMPERATURE AT 120°F

(49°C) WILL REDUCE THE RISK OF SCALDS. Some states or provinces require settings at specific lower temperatures.

Below you will find listed the approximate time-to-burn relationship for normal adult skin. Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat setting by up to 20°F (11°C). If you experience this type of use, you should consider using lower temperature settings to reduce scald hazards.

IGNITOR ASSEMBLY

For access to ignitor assembly, unfasten two screws to burner cover and remove. Locate the burner with the ignitor assembly and remove screw holding burner to manifold. Slide burner out to access ignitor assembly.

Servicing of the ignitor assembly includes keeping the ignitor free of lint, scale or any other foreign debris.

Water

Temperature

Time to Produce 2nd & 3rd

Degree Burns on Adult Skin

185°F

180°F

170°F

160°F

150°F

140°F

130°F

120°F

Nearly instantaneous

Nearly instantaneous

Nearly instantaneous

About 1/2 second

About 1-1/2 seconds

Less than 5 seconds

About 30 seconds

More than 5 minutes

Valves for reducing point-of-use temperature by mixing cold and hot water are available. Also available are inexpensive devices that attach to faucets to limit hot water temperatures. Contact a licensed plumber or the local plumbing authority.

FIGURE 11

MAIN BURNER

The main burner, see Figure 12, should display the following characteristics:

• Cause rapid ignition and carry across entire burner.

• Give reasonably quiet operation during ignition, burning, and extinction.

• Cause no excessive lifting of flame from burner ports.

The water temperature is controlled by a thermostat, see Figure

3, which has two sensing elements. One sensor is located near the top of the tank and the other is near the center. The thermostat is set in the lowest position before the heater leaves the factory.

FIGURE 12

The thermostat temperature dial, see Figure 3, is accessible by removing the control cover. The dial is adjustable and may

20

If the preceding burner characteristics are not evident, check for accumulation of lint, scale or other foreign debris that restricts or blocks the air openings to the burner or heater.

NOTE:

1. Remove main burners from unit.

2. Check that burner venturi and ports are free of foreign debris.

3. Clean burners with bristle brush and/or vacuum cleaner

- DO NOT distort burner ports or pilot location.

4. Reinstall burners in unit. Make sure front and rear of burners are installed correctly in burner support brackets.

Also check for good flow of combustion and ventilating air to the unit. Maintain a clear area around the heater at all times.

3. Remove the regulator adjustment sealing cap, see

Figure 13, and adjust the pressure by turning the adjusting screw with a screwdriver.

Clockwise to increase gas pressure and input rate.

Counterclockwise to decrease gas pressure and input

rate.

4. “Clock” the meter as in step 2 above.

5. Repeat steps 3 and 4 until the specified input rate is achieved.

6. Turn the gas control knob to PILOT. Remove the pressure gauge and replace the sealing cap and the allen wrench set screw in the pressure tap opening.

GAS VALVES

Figure 13 shows the type of combination manual gas control valve and regulator used on these heaters.

If the gas valve becomes defective, repairs should not be attempted. A new valve should be installed in place of the defective one.

WARNING

UNDER NO CIRCUMSTANCES SHOULD THE GAS INPUT

EXCEED THE INPUT SHOWN ON THE HEATER MODEL AND

RATING PLATE. OVERFIRING COULD RESULT IN DAMAGE

OR SOOTING OF THE HEATER.

When the heater is operating at full capacity, or full gas input, it should consume 1 cu. ft. of gas in time indicated on Table 3.

FIGURE 13

TABLE 3

APPROXIMATE TIME REQUIRED TO CONSUME

INPUT

RATE

(BTUH)

TYPE

OF

GAS

BTUH

PER

CU. FT.

TIME REQ’D

TO CONSUME

1 CU. FT.

OF GAS

154,000

199,000

NATURAL

NATURAL

1050

1050

24.5 SEC.

19.0 SEC.

CHECKING THE INPUT

For appliance installation locations with elevations above

2000 feet, refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure.

1. Attach a pressure gauge or a manometer to the gauge port and refer to the GAS PRESSURE REGULATOR section for correct manifold pressure.

Figures shown are valid for 0-2000 ft.(0-610m) installations. See

“HIGH ALTITUDE INSTALLATIONS” for deration requirements over 2000 ft.(610m).

VENTING SYSTEM

Examine the venting system every six months for obstructions and/or deterioration of the vent piping.

2. Use this formula to “clock” the meter. Be sure that other gas consuming appliances are not operating during this interval.

Remove all soot or other obstructions from chimney which will retard free draft.

3600 X H = Btuh

T

T = Time in seconds to burn one cubic foot of gas.

H = Btu’s per cubic foot of gas.

REMOTE STORAGE TANK

TEMPERATURE CONTROL

The water temperature in the storage tank (if used) is controlled by the storage tank temperature control. The sensing element is mounted in the hot water storage tank, see page 17.

Btuh = Actual heater input.

Example:

T = 15.1 seconds

H = 1050 Btu

A change in water temperature in the storage tank lower than the tank temperature control setting will cause the sensor to activate the circulating pump. The pump then circulates the water through the heater where the thermostat senses the drop in water temperature and activates main burner operation of the appliance.

If the storage tank temperature control is out of calibration, replace with new control.

Btuh = ?

19 X 1050 = 199,999 Btuh

Should it be necessary to adjust the gas pressure to the burners to obtain the full input rate, the steps below should be followed:

21

WARNING

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL

TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL

VALVE TO THE APPLIANCE.

RELIEF VALVE

At least once a year, the temperature and pressure relief valve should be checked to ensure that it is in operating condition. Lift the lever at the top of the valve several times until the valve seats properly and operates freely.

NOTE: Anode rod inspection may need to be made more frequently in areas subject to acid rain that obtains their water supply from surface water as the low pH will accelerate anode activity.

WARNING

THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING

OPERATION MAY BE EXTREMELY HOT. AVOID CONTACT AND

DISCHARGE SAFELY TO PREVENT WATER DAMAGE.

CAUTION: Close cold water inlet valve serving heater and open nearby hot water faucet to relieve the pressure in the heater before attempting to remove anode(s) for inspection.

If the appliance installation includes other relief valves, such as in “remote” storage tanks etc., check their relief valve operation with the same frequency.

FLUSHING

1. Turn off the heater electrical disconnect switch.

2. Open the drain valve and allow water to flow until it runs clean.

3. Close the drain valve when finished flushing.

4. Turn on the heater electrical disconnect switch.

If the temperature and pressure relief valve on the heater discharges periodically or continuously, a problem exists. This may be due to unusually high water temperatures or pressures in the system, or to a faulty relief valve. Contact your dealer or a qualified service technician to find the cause of the problem and to correct it. This may also be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation.

DO NOT PLUG THE TEMPERATURE AND PRESSURE

RELIEF VALVE.

WARNING

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL

TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL

VALVE TO THE APPLIANCE.

HOT WATER ODOR

On occasion, hot water may develop a strong odor. If this occurs drain the heater completely, flush thoroughly, and refill. If the problem persists, chlorination of the heater and replacement of the factory installed magnesium anodes with aluminum anodes may correct the condition.

DRAINING

The heater must be drained if it is to be shut down and exposed to freezing temperatures. Maintenance and service procedures may also require draining the heater.

1. Turn off the heater electrical disconnect switch.

2. Close the cold water inlet valve to heater.

3. Open a nearby hot water faucet to vent the system.

4. Open the heater drain valve.

5. If the heater is being drained for an extended shutdown, it is suggested the drain valve be left open during this period.

• Follow FILLING instructions when restoring hot water service.

RECOMMENDED PROCEDURE FOR PERIODIC

REMOVAL OF LIME DEPOSITS FROM TANK

TYPE COMMERCIAL WATER HEATERS

Occasionally water softener companies recommend removal of heater anodes for odor reasons.

The amount of calcium carbonate (lime) released from water is in direct proportion to water temperature and usage, see chart.

The higher the water temperature or water usage, the more lime deposits are dropped out of the water. This is the lime scale which forms in pipes, heaters and on cooking utensils.

CAUTION

Unauthorized removal of the anode(s) will void the warranty.

For further information contact your dealer.

ANODE ROD INSPECTION

The heater tank is equipped with anode rods to provide corrosion control. At least once a year the anode rods should be checked to determine if replacement is necessary. Initially the anode rods are approximately 7/8” in diameter with a 1/8” diameter steel core wire running down the center of the anode material. THE ANODES SHOULD BE REPLACED when the

1/8” diameter core wire is visible as this means that the anode material has been expended in the control of corrosion.

For models with top inlet and outlet, it is recommended that, before removing the inner cover for cleaning, inspection or removal of inner parts, you obtain two new nipple collars. The nipple collars on the heater will usually be damaged when removed. New pipe collars will insure that the seal is such as to prevent leakage of flue products when properly installed.

Lime accumulation not only reduces the life of equipment but also reduces efficiency of the heater and increases fuel consumption.

The usage of water softening equipment greatly reduces the hardness of the water. However, this equipment does not always remove all of the hardness (lime). For this reason it is recommended that a regular schedule for deliming be maintained.

The time between cleaning will vary from weeks to months depending upon water conditions and usage. The depth of lime buildup should be measured periodically. Heaters equipped with cleanouts will have about 2” of lime buildup when the level of lime has reached the bottom of the cleanout opening. A schedule for deliming should then be set up,based on the amount of time it would take for a 1” buildup of lime. It is recommended that the water heater initially be inspected after 6 months.

Example 1:

If initial inspection after 6 months shows 1/2” of lime accumulation.

Therefore, the heater should be delimed once a year.

22

Example 2:

If initial inspection after 6 months shows 2” of lime accumulation.

Therefore, the heater should be delimed every 3 months.

6. Install cleanout plate. Be sure to draw plate up tight by tightening screws securely.

7. Replace outer jacket cover plate.

FIGURE 14

In some water areas the sediment might not be removed by this method and may result in the water heater making rumbling or boiling noises.

IGNITION MODULE SYSTEM

Before calling your service agent, the following checklist should be examined to eliminate obvious problems from those requiring replacement or servicing.

— Check that “main manual gas shutoff valve” is fully open and that gas service has not been interrupted.

— Check that after following the appliance OPERATING

INSTRUCTIONS, the “Top Knob” of the appliance gas valve is in “ON” position.

— Check electrical supply to the appliance for possible blown (or tripped) fusing or power interruption.

— Is the water temperature in tank below the thermostat dial setting on the appliance thermostat (calling for heat)?

— It is possible that the high limit (E.C.O.) has functioned to shut off the appliance. See FEATURES — Water Temperature

Control for reset procedure. Contact your serviceman if limit continues to function to shut off appliance.

DELIMING SOLVENTS

Hydrochloric base acids are not recommended for use on glass lined tanks.

CAUTION

Observe handling instructions on label of product being used.

TANK CLEANOUT PROCEDURE

The following practices will ensure longer life and enable the unit to operate at its designed efficiency:

1. Once a month the heater should be flushed. Open drain valve and allow two gallons of water to drain from the heater. Inlet water valve should remain open to maintain pressure in tank.

2. A cleanout opening is provided for periodic cleaning of the tank.

Gas must be shut off and heater drained before opening cleanout.

To clean heater through cleanout opening, proceed as follows:

1. Drain heater.

2. Remove outer cover plate from lower side of heater jacket.

3. Remove six (6) hex head screws securing tank cleanout plate and remove plate.

SYSTEM DIAGNOSTICS

Your water heater is equipped with an ignition module that incorporates a diagnostic system to assist in troubleshooting the appliance. The indicator codes on the ignition module are as follows:

1 flash

System lockout (retries or cycles exceeded)

2 flashes

Pressure switch stuck close

3 flashes

Pressure switch stuck open

4 flashes

Open on high temperature limit switch (eco)

6 flashes

115 volt AC power reversed (check polarity)

7 flashes

Low flame sense signal (make sure flame sensor is in burner flame)

8 flashes

Check ignitor continuous flash -> continuous flame sensed > 5 seconds without gas valve continuous on -> internal control failure - replace ignition control module.

4. Remove lime, scale, or sediment using care not to damage the glass lining.

5. Inspect cleanout plate gasket, if new gasket is required, replace with part no. 9004099215.

Use this diagnostic system in conjunction with the “OPERATIONAL

CHECKLIST” and the “SEQUENCE OF OPERATION” to troubleshoot the appliance.

23

SERVICE

The installer may be able to observe and correct certain problems which may arise when the unit is put into operation. HOWEVER, it is recommended that only qualified servicemen, using appropriate test equipment, be allowed to service the heater.

As preliminary step, check wiring against diagram, check for grounded, broken or loose wires. Check all wire ends to be sure that they are making good contact.

ELECTRICAL SERVICING

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN

SERVICING CONTROLS. WIRING ERRORS CAN CAUSE

IMPROPER AND DANGEROUS OPERATION.

VERIFY PROPER OPERATION AFTER SERVICING.

REPLACEMENT PARTS

Replacement parts may be ordered through Lochinvar dealers, authorized servicers or distributors. Refer to the

Yellow Pages for where to call or contact the Parts

Department, 300 Maddox Simpson Pkwy, Lebanon,

TN 37090, Phone: 615-889-8900 • Fax: 615-882-2918, email: [email protected], www.Lochinvar.com.

When ordering parts be sure to state the quantity, part number and description of the item(s) including the complete model and serial number as it appears on the product. Refer to the part’s list for more information.

24

SEQUENCE OF OPERATION FLOW CHART

Description of this flow chart can be found in the “SEQUENCE OF OPERATION” section found on page 18.

Switch power on to unit.

Ignition

Control Board opens Gas

Valve.

Thermostat calls for heat.

Ignition Control

Board performs diagnostic check on components

Ignition Control

Board shuts off

Silicon Nitride

Ignitor after

3 seconds

Ignition Control

Board waits 3 more seconds to monitor Flame

Sensor.

Ignition Control

Board sends power to Exhaust Inducer

Did Main

Burner Light?

NO

Ignition Control

Board shuts off Gas

Valve and allows the

Exhaust Inducer to purge appliance for

20 seconds.

Exhaust Inducer engages Prover

Switch

Ignition Control

Board provides power to Silicon

Nitride Ignitor

YES

Ignition Control

Board monitors units until T’Stat is satisfied.

Silicon Nitride

Ignitor warms up for

20 seconds

25

OPERATIONAL CHECKLIST

This checklist in conjunction with “TROUBLESHOOTING” and the “SEQUENCE OF OPERATION” should be used as an on-the-job troubleshooting guide to identify the cause of incorrect system operation and suggest a remedy for its correction. Because improper piping and wiring can result in unsatisfactory system performance, it is suggested that the installation be examined before using the checklist. Be sure to refer to the correct piping and wiring diagram for the type of system that is installed.

The system should be filled with water, purged of air, valves properly set and utilities connected and ready to operate.

REMEDY

If leakage source cannot be corrected or identified, call serviceman.

Heater is overfired.

Possible gas leaks.

26

Limited Warranty

Lochinvar, LLC the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater.

1. THE TANK

If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the first THREE years after initial installation, the warrantor will supply a complete new Lochinvar water heater of equivalent size and current model at the warrantor's option. Some government agencies are requiring energy efficient standards for water heaters. In the event regulations prohibit sale of a model of equivalent size and construction, Lochinvar will provide a model which complies with the regulations of your area, in which case the consumer will be charged the difference in price between the like replacement and the energy efficient model required. The warranty on the replacement water heater will be limited to the unexpired term of the original warranty.

2. ALL OTHER PARTS

If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in material or workmanship, the warrantor will repair or replace such part or portion at its option.

3. CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed in accordance with local plumbing and building codes, ordinances and regulations, the printed instructions provided with it and good industry practices. In addition, a temperature and pressure relief valve, certified by CSA and approved by the American

Society of Mechanical Engineers, must have been installed. a. This warranty shall apply only when the water heater is:

(1) owned by the original purchaser;

(2) used at temperatures not exceeding the maximum setting of its thermostat;

(3) used at water pressure not exceeding the working pressure shown on the heater;

(4) used when operated free of the damaging effects of uncontrolled water hammer;

(5) used when filled with potable water, free to circulate at all times;

(6) used in a non-corrosive and non-contaminated atmosphere;

(7) used with factory approved anode(s) installed;

(8) in its original installation location;

(9) in the United States, its territories or possessions, and Canada;

(10) sized in accordance with proper sizing techniques for commercial water heaters;

(11) bearing a rating plate which has not been altered, defaced or removed except as required by the warrantor;

(12) fired at the factory rated input using the fuel stated on the rating plate in the case of gas models or fired at the proper voltage and wattage in the case of electric models

(13) maintained in accordance with the instructions printed in the manual included with the water heater. b. Any accident to the water heater, any misuse, abuse (including freezing) or alteration of it, any operation of it in a modified form, or any attempt to repair tank leaks will void this warranty. c. This warranty is void if a device acting as a backflow prevention device (check valves etc.) is installed in the cold water supply the heater is connected to, unless an effective method of controlling thermal expansion is also installed at the heater(s) and operational at all times.

The temperature and pressure relief valve installed on the heater is not an acceptable method.

4. SERVICE AND REPAIR EXPENSES

Under the limited warranty the warrantor will provide only a replacement water heater or part thereof. The owner is responsible for all other costs. Such costs may include but are not limited to: a. Labor charges for service removal, repair or reinstallation of the water heater or any component part; b. Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest distributor and returning the claimed defective heater or part to such distributor. c. All cost necessary or incidental for any material and/or permits required for installation of the replacement.

5. LIMITATIONS ON IMPLIED WARRANTIES

Implied warranties, including the warranty of merchantability imposed on the sale of this heater under state law are limited to one (1) year duration for the heater or any of its parts. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

6. CLAIM PROCEDURE

Any claim under the warranty should be initiated with the dealer who sold the water heater, or with any other dealer handling the warrantor’s products. If this is not practicable, the owner should contact:

Lochinvar, LLC

300 Maddox Simpson Pkwy

Lebanon, TN 37090

(615) 889-8900 a. The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the warrantor. b. Dealer replacements are made subject to in-warranty validation by warrantor.

7. DISCLAIMERS

NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY

OF THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE WATER HEATER. THE WARRANTOR SHALL NOT BE

RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER

CONSEQUENTIAL DAMAGE. THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY

PERSONS OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING IN CONTRACT OR TORT. a. Some states do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may not apply to you. b. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Fill in the following for your own reference. Keep it. Registration is not a condition of warranty. The model and serial number are found on the heater’s rating plate.

Date Installed________________________Model No.____________________________________________Serial No._________________________________________

Dealer’s Name _____________________________________________________________________Phone No.________________________________________________

Dealer’s Address__________________________________________________City and State________________________________________Zip Code________________

FILL IN WARANTY AND KEEP FOR FUTURE REFERENCE

27

300 Maddox Simpson Parkway

Lebanon, TN 37090

Phone: 615-889-8900 • Fax: 615-547-1000

Technical Service email: [email protected]

www.Lochinvar.com

Copyright © 2011 Lochinvar, LLC, All rights reserved.

28