LaCie 12big Rack Storage Server Quick Install Guide
LaCie 12big Rack Fibre 8 is a high-performance rackmount storage solution designed for demanding IT environments. With its 12 drive bays, it can store up to 96TB of data, making it ideal for large-scale data storage and backup. The Fibre Channel interface provides fast and reliable data transfer speeds, while the hot-swappable drive bays allow for easy maintenance and scalability.
Advertisement
Advertisement
12big Rack Storage Server
Quick Install Guide
EN
ENGLISH
TABLE OF CONTENTS
LaCie Quick Install Guide 2
1. INTRODUCTION
1.1. Safe Handling
An enclosure can weigh up to 36kg (79.2lb). Do not try to lift it by yourself.
Do not lift the enclosure by the handles on the Battery Modules.
They are not designed to take the weight.
1.2. Safety
All plug-in modules and blank plates are part of the fire enclosure and must only be removed when a replacement can be immediately added.
The system must not be run without all units in place. In order to comply with applicable safety, emission and thermal requirements no covers should be removed.
Permanently unplug the unit if you think that it has become damaged in any way and before you move it.
The unit must only be operated from a power supply input voltage range of 100-240 VAC, 50-60 Hz.
The plug on the power supply cord is used as the main disconnect device. Ensure that the socket outlets are located near the equipment and are easily accessible.
The power connection must always be disconnected prior to removal of a PSU module from the enclosure.
A safe electrical earth connection must be provided to the power cord. Check the grounding of the enclosure before applying power.
Provide a suitable power source with electrical overload protection to meet the requirements laid down in the technical specification.
This equipment is intended to operate with two working PSUs installed in the Power Supply Module. Before removal/replacement of a PSU disconnect all power for isolation.
A faulty PSU must be replaced with a fully operational one within
24 hours.
CAUTION: If this equipment is used in a manner not specified by LaCie, the protection provided by the equipment may be impaired.
IMPORTANT INFO: The enclosure top cover must be secured, when the enclosure is in normal use, by rotating the lock 90° to the ‘locked’ position. This is to prevent users/operators from accessing the service areas.
CAUTION: The RJ45 sockets on the motherboard/PCI cards are for Ethernet connection only and must not be connected to a telecommunications network.
IMPORTANT INFO: Do not remove covers from the PSU. Danger of electric shock inside. Return the PSU to LaCie for repair.
IMPORTANT INFO: Bifurcated power cords must NOT be used with the
12big Rack Storage Server.
1.3. ESD Precautions
It is recommended that you fit and check a suitable anti-static wrist or ankle strap and observe all conventional ESD precautions when handling plug-in modules and components. Avoid contact with backplane components and module connectors, etc.
1.4. Rack System Precautions
The following safety requirements must be considered when the unit is mounted in a rack.
The rack design should incorporate stabilizing features suitable to prevent the rack from tipping or being pushed over during installation or in normal use.
When loading a rack with the units, fill the rack from the bottom up and empty from the top down.
The rack design should take into consider-ation the maximum operating ambient temperature for the unit, which is 35°C.
The system must be operated with low pressure rear exhaust installation (back pressure created by rack doors and obstacles not to exceed 5 pascals (0.5mm water gauge)).
The rack should have a safe electrical distribution system. It must provide over-current protection for the unit and must not be overloaded by the total number of units installed in the rack. Consideration of the electrical power consumption rating shown on the unit’s nameplate should be used when addressing these concerns.
The electrical distribution system must provide a reliable earth for each unit in the rack.
Each power supply in each unit has an earth leakage current of
0.75mA. The design of the electrical distribution system must take into consideration the total earth leakage current from all the power supplies in all the units. The rack will require labelling with “HIGH
LEAKAGE CURRENT. Earth connection essential before connecting supply”.
The rack, when configured with the units, must meet the safety requirements of UL 60950-1 and IEC 60950-1.
2. PREPARATION
2.1. Before You Begin
Before you begin, make sure the site where you intend to set up and use your enclosure has the following:
Standard power from an independent source or a rack power distribution unit with a UPS.
Power Cord
Rack kit (if installing within a rack)
Refer to LaCie for a list of qualified accessories for use with the enclosure.
The Accessory Box contains the power cords and other ordered accessories.
LaCie Quick Install Guide 3
2.2. Unpacking
1. Inspect the packaging for crushes, cuts, water damage or any other evidence of mishandling during transit. If any damage appears present, photograph the packaging before opening, for reference.
2. Unpack the system. See Figure 1.
3. INSTALLATION
3.1. Mounting the System into a Rack
NOTE: The rail kit is suitable for 19” racks with square and round holes only. The minimum distance between vertical rack posts is 24” (610mm); the maximum distance is 36” (914mm). The rail location pins are preassembled to suit square hole or round hole racks. The pins should not be removed.
1. Remove the Rack Mounting Rail Kit from the Accessory Box and check for damage.
2. Ensure the pre-assembled rails are at their shortest length.
3. Locate the rail location pins inside the front of the rack and extend the rails to enable the rear location pins to engage. Ensure the pins are fully located in the holes in the rack posts (see Figure 2).
4. Install the front and rar clamping screws (see Figure 2). The screws should be left loose enough to allow the rail to move sideways on its slots.
5. Slide the enclosure fully home on its rails.
6. Withdraw the enclosure approximately 200mm and fully tighten the front and rear clamping screws (see Figure 2).
7. Fasten the front of the enclosure using the two captive screws a shown in Figure 2.
Figure 1 - Unpacking the Enclosure
Figure 2 - Rack Installation
LaCie Quick Install Guide 4
3.2. Fitting Modules
Fit the modules into the bays defined in Figure 3.
IMPORTANT INFO: The removal of the enclosure top cover or a PSU module must only be performed by service personnel. Potential hazards include rotating fans and hot surfaces. The screws or latches securing the enclosure top cover and PSU modules must be firmly tightened to prevent unauthorized access to those areas.
3.4. Removing PSUs
IMPORTANT INFO: Prior to removing the PSU from the mounting cage, please disconnect the power from the power supply, by either the switch
(where present) or by physically removing the power source, to ensure your system has warning of an imminent power shutdown. Do not remove the faulty PSU unless you have a replacement ready for insertion.
You can continue working while replacing the faulty PSU.
1. Make sure you identify the faulty PSU correctly from the two installed.
2. Switch off and disconnect the power supply cord.
3. Squeeze retaining handle to the left to release (see Figure 4a).
4. Grip the handle and withdraw the PSU (Figure 4b).
Figure 3: Module Locations
3.3. Fitting PSUs
Two PSUs are installed in the mounting cage at the rear of the enclosure.
IMPORTANT INFO: Do not remove covers from the PSU. Danger of electric shock inside. Return the PSU to LaCie for repair.
1. Check for damage, especially to the rear connector on the PSU.
2. Handle the PSU carefully and avoid damaging the connector pins.
Do not install the PSU if any pins appear to be bent.
3. Slide the PSU into the mounting cage.
4. Push firmly until a click is heard as the securing spring engages.
NOTE: This module must only be removed by service personnel.
5. You are now ready to connect the power supply cords to the power sources and switch the power supply ON.
Figure 4a: Removing a PSU
Figure 4b: Removing a PSU
LaCie Quick Install Guide 5
3.5. Replacing a Fan
IMPORTANT INFO: The cover must only be opened by service personnel.
1. Release the enclosure top cover by turning the lock mechanism to the ‘Unlocked’ position and slide the cover back until it stops (see
Figure 5).
Figure 5: Removing the Enclosure Cover
2. Grip the faulty Fan module with finger and thumb and pull it upwards in order to unplug it, and remove it from the enclosure
(see Figure 6).
3. Check the Fan for damage. Do not install it if there are any visible signs of damage.
4. Replace the Fan by pushing it all the way into the enclosure until it fits firmly and is level with the other Fans.
5. Ensure that the Fan module LED extinguishes within 10 seconds of installation.
6. Close the enclosure cover and secure by turning the lock mechanism to the ‘Locked’ position.
3.6. Battery Safety
Replacing batteries on the motherboard.
CAUTION: There is a danger of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries in accordance with the manufacturer’s instructions and national regulations.
CAUTION: The batteries on the NVRAM card(s) are not replaceable; the complete card assembly must be replaced in the event of battery failure.
Therefore the complete card assembly must be replaced annually or in the event of battery failure.
3.7. Fitting Drives
CAUTION: Operation of the enclosure with ANY drive carrier modules missing will disrupt the airflow and the drives will not receive sufficient cooling. It is essential that all apertures are filled before operating the unit.
Dummy drive carrier modules are available for fitting to unused drive bays.
1. Release the carrier handle by pressing the latch in the handle towards the right and insert the carrier into the enclosure.
IMPORTANT INFO: Ensure that the carrier is orientated so that the drive is uppermost and the handle opens from the left (See Figure 7).
2. Slide the carrier, gently, all the way into the enclosure.
3. Cam the carrier home - the camming foot on the base of the carrier will engage into the slot in the enclosure.
4. When the carrier is fully home, close the handle - a click should be heard as the latch engages.
IMPORTANT INFO: Ensure that all drive carriers are fully engaged in the enclosure by firmly pushing each one home fully into the slot (See
Figure 8).
Figure 6: Removing a Fan
IMPORTANT INFO: To avoid injury, ensure that the blades have stopped rotating before handling the fan.
LaCie Quick Install Guide 6
Figure 7: Drive Carrier Module (Note: ensure that the handle always opens from the left.)
3.8. Operator Panel
LED
Power On
Fault
Enclosure ID
Color
Green
Amber
Blue
Normal
On
Off
N/A
Fault
On
On
N/A
Figure 8: Fitting Drives (Note: ensure the carriers are fully engaged in the enclosure.)
Figure 9: Operator Panel
LaCie Quick Install Guide 7
4. MANAGING YOUR RAID
The 12big Rack Storage Server comes with a preconfigured RAID 5 array on the three first data drives, which contain the operating system partition.
This chapter explains how you can migrate, expand, or reconstruct your
RAID. The operating system CD is provided if you wish to build a customized configuration from scratch.
4.1. Start up and log in
1. Connect a monitor, mouse, and keyboard to the 12big Rack Storage
Server and boot the system.
2. Follow the steps in the Set Up Windows wizard, then log on as an administrator.
Password: LaCie12big (case sensitive)
3. Start LSI MegaRAID management software from start menu or desktop.
4. The LSI administration page will open. Select your server and click
Connect .
4.2. Migrating your RAID configuration
Out of the box, only three drives are pre-configured. The operating system resides on these three drives. This section explains how you can add unconfigured drives to the current RAID array or migrate from a RAID 5 to a
RAID 6 configuration.
CAUTION: Be sure to back up your data before you change the RAID level.
CAUTION: Migrating a RAID cannot be stopped and will disable any other RAID operations during processing.
1. Click the Logical tab in the left panel of the MegaRAID Storage Manager window.
2. Select a drive group in the left panel of the window.
3. Select Go To > Drive Group > Modify Drive Group on the menu bar, or right-click the virtual drive icon to access the Modify Drive
Group Wizard . The Modify Drive Group Wizard window appears.
Figure 11 - LSI Startup Dialog Window
NOTE: In the standard default configuration, only the local server will be displayed.
5. By default, the credentials are:
Login: Administrator
Password: LaCie12big
6. The main MegaRAID Storage Manager window will open. Under the Physical tab, select the MegaRAID SAS 9280-4i4e board.
Figure 12 - Change RAID Level
LaCie Quick Install Guide 8
4. On the Modify Drive Group Wizard screen, select the RAID level that you want to change (“migrate”) the drive group to and click
Next . A screen states the number of drives that you have to add if new RAID level that require more drives.
7. Click Yes to accept and complete the migration to the new RAID level.
You can monitor the progress of the RAID level change by selecting Manage > Show Progress in the menu bar.
4.3. Create a RAID-Protected Disk
Array
This section explains how to configure additional drives with custom settings.
1. Select Go To > Controller > Create Virtual Drive to start configuring your RAID array. Select Advanced and press Next .
Figure 13 - Select Drives for RAID Configuration
5. Select the unconfigured drive or drives to add and click Next .
NOTE: The drive(s) you add must have the same capacity as or greater capacity than the drives already in the drive group, or you will not be able to change the RAID level.
Figure 15 - Create Virtual Drive wizard
2. Beneath the list of available drives, proceed as follows for each disk array: a. Select the drives you want to include in your array in Unconfigured Drives view.
CAUTION: Your operating system is pre installed on the first three data drives. Removing the RAID configuration of those drives will delete the pre-installed operating system.
NOTE: You can select multiple drives by holding the Ctrl key.
b. Click the Add button to move the drives to the Available Arrays pane. If you make an error, select the drive and click Remove .
Figure 14 - RAID Configuration Summary Screen
6. Review the configuration information. Click Back to modify or Finish to accept the changes. A confirmation message appears since this operation cannot be aborted.
LaCie Quick Install Guide 9
c. For each array to create, click the Create Array Group button.
5. Click Next when finished.
6. Review the configuration shown in the Virtual Disk Summary window. If you want to change something, click Back and change the configuration parameters. Otherwise, click Finish to accept the configuration and start the initialization process (unless you selected No
Initialization above).
4.4. Mount the Array
1. To access your drive configuration, launch Server Manager from the Windows Start Menu and select Storage > Disk Management .
Figure 16 - Create Drive Group
3. When all arrays have been created, click Next .
4. In the Virtual Disk Properties screen, modify default settings as follows in order to achieve best performance: a. RAID level: RAID 6 for the best protection and RAID 5 for the best protection/cost-per-TB ratio). b. Initialization state: Full initialization c. Stripe size: 256KB minimum d. Read policy: Always Read Ahead e. Write policy: Always write back f. I/O policy: Direct IO g. Access policy: Read Write h. Disk cache policy: Enabled i. Click Create Virtual Drive for each one you want to create.
Settings might be modified using Update Virtual Drive button.
Figure 18 - Windows Storage Management
2. The Initialize Disk window should appear. If not, right-click the desired disk and select Initialize Disk .
3. Select GPT if your volume is greater than 2TB (GUID Partition Table) and click OK .
4. Right-click on the desired disk and select New simple volume .
5. When formatting is completed, the disk should appear as Healthy .
The logical volume is now mounted and should appear in your Windows
Explorer.
4.5. Share the volume
If you need assistance to configure SMB and NFS shares, please refer to associated technical paper available on the LaCie website and on product
CD: http://www.lacie.com/download/more/Tech_Briefs/TB_Shared_
Folders_en.pdf
12big Rack Storage Server is delivered with pre installed Extreme Z-IP to allow Mac compatibility and Time Machine backup configuration. For more details, please refer to documentation available on product CD or in Start Menu > Programs > Extreme Z-IP .
Figure 17 - Advance Settings
LaCie Quick Install Guide 10
Contact Us
LaCie Asia
25/F Winsan Tower
98 Thomson Road
Wanchai, Hong-Kong, China [email protected]
LaCie Australia
458 Gardeners Road
Alexandria, NSW 2015 [email protected]
LaCie Benelux
Vorstlaan / 165 Bld du Souverain
B-1160 Brussels, Belgium [email protected]
LaCie Canada
103 The East Mall, Unit 1
Toronto, Ontario [email protected]
LaCie France
17, rue Ampère
91349 Massy Cedex [email protected]
LaCie Germany
Am Kesselhaus 5
D-79576 Weil Am Rhein [email protected]
LaCie Italy
Milano Business Park
Edificio B1
Via dei Missaglia 97
20142 Milano [email protected]
Elecom – Japan
http://www.lacie.jp/support/
LaCie Nordic
(Sweden, Denmark, Norway, Finland)
Sveavägen 90, 5tr
113 59 Stockholm, Sweden [email protected]
LaCie Spain
C/ Núñez Morgado, 3, 5 a pl.
28036 Madrid [email protected]
LaCie Switzerland
Davidsbodenstrasse 15A
4004 Basel [email protected]
LaCie United Kingdom and Ireland
LaCie Ltd, Power Road Studios
114 Power Road
Chiswick, London, UK W4 5PY
Ireland: [email protected]
LaCie USA
22985 NW Evergreen Pkwy
Hillsboro, OR 97124 [email protected]
LaCie Worldwide Export
17, rue Ampère
91349 Massy Cedex, France [email protected]
Visit www.lacie.com for more information on LaCie products.
Copyright © 2011, LaCie xxxxxx 110610
LaCie Quick Install Guide 11
Advertisement
Key features
- RAID 5 or 6 configuration
- Rack mountable
- Replaceable fans
- Two PSUs
- Extreme Z-IP for Mac compatibility
- LSI MegaRAID management software