mancooler AXIAL AND CENTRIFUGAL F General Description Technical Advice

mancooler AXIAL AND CENTRIFUGAL F General Description Technical Advice
Technical Advice
Fanquip offer a range of sturdy, high
Fanquip have technical consultants available to give
performance, durable Mobile Mancooler
fans. Fanquip Mobile Mancooler fans are
ideal for heavy duty applications, extracting
hot air, dust, smoke, etc, or providing a flow
of fresh air to machinery and personnel.
High volumes of air are obtainable making
this unit suitable for a variety of industries.
Each fan is fully guarded to the Australian
standard for complete safety. The precision
designed units are strong, yet easy to
manoeuvre. The Fanquip Mini Mancooler
range is suitable for situations with limited
space, where a steady airflow is required.
advice on the correct choice of Mancooler Fans for
your needs.
Maintenance
Maintenance instructions should be followed to ensure
satisfactory performance and service life.
Warranty
Twelve months guarantee on mechanical and electrical
componentry subject to satisfactory maintenance with
assessment and rectification, if any, to take place after
return by customer to Fanquip’s workshop.
The larger size Fanquip range offers a wide
choice of air movement to cover all needs.
coupled directly to the impeller assembly.
A heavy duty on/ off switch is fitted to the
Mobile
Mancooler
The motors are centrally mounted and
drum. All units are complete with overload
protection. Each Fanquip unit is enamel
finished in an attractive easy care colour.
For operation in hazardous locations, Ex(d)
corrosive environments, drum casings can
be fabricated in stainless steal or aluminium.
The complete fan units can be coated in
Mini
Mancooler
and Ex(e) motor protection is available. For
epoxy resin for added protection.
For more details, or to receive a
copy of one of our other brochures,
simply contact us now on
1800 224 308
Fanquip. PO Box 3150,
Singleton DC NSW 2330
Fax: 1800 882 529
Email: [email protected]
www.fanquip.com.au
AXIAL AND CENTRIFUGAL FANS AND BLOWERS FOR ALL INDUSTRIES
General Description
AXIAL AND CENTRIFUGAL FANS AND BLOWERS FOR ALL INDUSTRIES
mancoolerfans
Australia’s leading fan company
mancoolerfans
A GREAT RANGE OF MANCOOLERS FROM AUSTRALIA’S NUMBER ONE FAN DISTRIBUTOR....
Mobile Mancooler Fans
Mini Mancooler Fans
The Fanquip Mobile Mancooler Fans have fan diameters ranging from 400 mm to 1000 mm. The drum body is
The Fanquip Mini Mancooler Fans have a blade diameter of 300 mm and 400 mm. The drum body is constructed
constructed from heavy gauge steel, flared at each end for protection. The frame is tubular steel, light but robust
in heavy gauge steel, strengthened at each end and protected with robust wire screens. The frame is tubular
and fitted with pivot bolts and locking nuts on each side to allow the drum to deflect the air beam 360°. Solid
steel, light but robust and fitted with pivot bolts on each side allowing air beam deflection of 360°. The centrally
rubber wheels on solid axles complete with the units. Swivel castors are also available. All fan impellers are
mounted motor is coupled direct to the blade assembly and the isolating switch is externally fitted.
adjustable pitch aerofoils to provide an efficient but quiet air flow.
Performance Data
Performance Data
Model
Number
Fan Diameter
(mm)
Motor Speed
(r/s)
Motor Power
(kW)
Free Air
Volume (I/s)
*Noise Level
dB(A)
1-40241/3
400
24
0.18
1500
52
1-40481/3
400
48
1.50
2500
74
1-50241/3
500
24
0.55
3000
63
1-60241/3
600
24
1.10
4400
68
1-61241/3
600
24
2.20
5800
72
1-80163
800
16
1.50
7000
66
1-80241/3
800
24
2.20
8000
74
1-10123
1000
12
3.00
12000
63
1-10163
1000
16
5.50
17000
78
Model
Number
Fan Diameter
(mm)
Motor Speed
(r/s)
Motor Power
(kW)
Free Air
Volume (I/s)
*Noise Level
dB(A)
1-30241/3
300
24
0.18
600
58
1-30481/3
300
48
1.75
1400
64
1-41241/3
400
24
0.18
1500
60
1-41281/3
400
48
1.10
2150
74
*Note: Noise level is indicative only and should only be used to indicate relative values,
as actual figures depend on the situation of the fan and the relevant field conditions.
All sizes etc shown are nominal. Subject to change without notice.
Dimensions
*Note: Noise level is indicative only and should only be used to indicate relative values,
as actual figures depend on the situation of the fan and the relevant field conditions.
All sizes etc shown are nominal. Subject to change without notice.
Dimensions
Fan Diameter
(mm)
A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
F
(mm)
G
(mm)
H
(mm)
Fan Diameter
(mm)
A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
F
(mm)
400
650
660
500
410
560
450
800
200 x 50
300
490
500
400
310
400
340
500
810
880
500
510
700
530
930
200 x 50
400
540
500
500
410
400
340
600
860
880
600
610
700
535
930
200 x 50
800
1050
1170
600
810
970
640
1050
200 x 50
1000
1370
1330
720
1015
1140
830
1260
300 x 50
For more information, simply call us Toll Free on: 1800 224 308... .
...visit us at: www.fanquip.com.au or email us: [email protected]