Marley Engineered Products B Fan Installation & Maintenance Instructions

Add to My manuals
4 Pages

advertisement

Marley Engineered Products B Fan Installation & Maintenance Instructions | Manualzz

9

1/

4

12 1/

2

FILE #E21609

SRA-DS Series Model B

Fan Forced Wall Heaters

11”

4”

1”

10 3/

8

Installation & Maintenance Instructions

Dear Owner,

Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley

Engineered Products. You have made a wise investment selecting the highest quality product in the heating industry. Please carefully read the installation and maintenance directions shown in this manual.

You should enjoy years of efficient heating comfort with this product from Marley Engineered Products...

the industry’s leader in design, manufacturing, quality and service.

... The Employees of

Marley Engineered Products

!

WARNING

Read Carefully - These instructions are written to help you prevent difficulties that might arise during installation of heaters. Studying the instructions first may save you considerable time and money later. Observe the following procedures, and cut your installation time to a minimum.

To reduce risk of fire or electric shock:

1.

Disconnect all power coming to heater at main service panel before wiring or servicing.

2.

All wiring must be in accordance with the National and Local

Electrical Codes and the heater must be grounded as a precaution against possible electric shock.

3.

Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing.

4.

This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.

5.

Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire,or damage to the heater.

6.

Do not block air intakes or exhaust in any manner. Keep combustible materials, such as crates, drapes, etc., away from heater. Do not install behind doors, furniture, towels, or boxes.

7.

Aheater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are stored.

8.

Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.

9.

This heater is not approved for use in corrosive atmospheres such as marine, green house or chemical storage areas.

SAVE THESE INSTRUCTIONS

1

IMPORTANT

!

!

WARNING

TO PREVENT HAZARD OF FIRE OR ELECTRICAL SHOCK, DO NOT

INSTALL WITHOUT BACK BOX.

CAUTION

!

FOR WALL MOUNTING, DO NOT INSTALL HEATER CLOSER THAN

2" (51mm) TO THE FLOOR OR ANY ADJACENT WALL SURFACE. DO

NOT INSTALL CLOSER THAN 36" (915mm) TO THE CEILING. FOR

CEILING MOUNTING, DO NOT INSTALL CLOSER THAN 12” (304mm)

TO ADJACENT WALL.

CAUTION

!

THE HEATER IS HOT WHEN IN USE. DO NOT INSTALL THE

HEATER BEHIND DOOR, BEHIND TOWEL RACK, IN CLOSET,

WHERE CURTAINS OR DRAPES COULD TOUCH OR BECOME

SCORCHED BY HEATER, OR WHERE AIRFLOW TO HEATER MAY

BE OBSTRUCTED. KEEP ELECTRICAL CORDS, BEDDING, FURNI-

TURE AND OTHER COMBUSTIBLES AWAY FROM HEATER.

4.

Run power supply cable through the connector, leaving about 8” of wire inside the box.

5.

Connect the supply cable ground wire to green ground screw provided.

NOTE: Lead holes for a #8 sheet metal screw have been provided in the sides of the back box.. After the finished wall or ceiling has been put up, drive a # 8(m4) sheet metal screw (recommended 1” long) through the side of the box not mounted to the stud. This will prevent the back box from pulling out when installing the heater assembly. (See Figure 1)

INSTALLATION OF BACK BOX

IN EXISTING CONSTRUCTION

(WALL OR CEILING)

1.

Carefully mark and cut a hole measuring 9-3/8" (235mm) wide by 11-

1/8" (283mm) long. One edge of the hole must be cut along the edge of a stud.

!

CAUTION

AN ELECTRICAL SHOCK, FIRE OR WATER DAMAGE COULD

RESULT IF WIRING OR PIPING IS DAMAGED DURING CUTTING.

MAKE SURE ALL WIRING AND PIPING ARE CLEAR OF AREA

BEFORE CUTTING.

GENERAL

The heater is designed for recessed installation in 2” X 4” (50mm X

101mm) stud or larger wall or ceiling sections using the wall box provided. The heater may also be surface mounted by using the Surface

Mounting Frame, Model SRASM or semi-recess mounted by using a

SRAS1 (for 1” (25 mm) recess frame) or a SRAS2 (for 2” (50mm) recess frame). All three accessories are ordered separately. The heater may be wired with standard building wire (60°C). Refer to specification chart (see pg. 4) for correct supply voltage and wire size.

NOTE: The optimum mounting height for this heater is 18" to 24" (450 to

600mm) from floor to bottom of back box. Do not install closer than

2”(50mm) from the floor. Back box may be mounted such that discharge portion of grille can be oriented down, left, right, or up.

For surface or semi-recess mounting, consult Installation Instructions packed with SRASM, SRAS1, SRAS2

2.

Proceed to No. 1 through 5 (Installation of Wall Box in New

Construction).

FIELD CONVERSION FOR LOWER WATTAGE RATING

NOTE: Refer to specification chart for lower wattage ratings which are available.

To convert heater to lower wattage rating, completely remove red jumper wire from both heating elements (See Figure 2). Discard this jumper. Be sure remaining wires are securely connected.

Remove red jumper for lower wattage rating

INSTALLATION OF WALL BOX

IN NEW CONSTRUCTION

(WALL OR CEILING)

NOTE: If the finished wall surface is already up, follow instructions for

“INSTALLATION OF BACK BOX IN EXISTING CONSTRUCTION”.

Figure 2

1.

Determine which side of the back box is to be mounted against a stud and bend the tabs at the rear corners out 90 degrees so that the back box will be square with the stud after installation. (See

Figure 1).

INSTALLATION AND WIRING

OF HEATER / FAN ASSEMBLY

1.

Following wiring diagram (Figure 3) connect supply wiring to heater leadwires in back box.

2.

Remove one of the knockouts on socket side of the back box and install a cable or conduit connector.

3.

Position back box against side of studs and secure using nails or screws as shown in Figure 1.

NOTE: For 120 and 277 volt heaters connect the white neutral supply lead to the heaters white pigtail lead, and connect the black supply lead to the heater black pigtail lead. For 208 and 240 volt heaters change the color of the heaters white pigtail lead to black by wrapping with black electrical tape. (Most electrical codes require the supply leads to be connected to black leads). Then connect the two black supply leads to the two black receptacle leads.

NOTE: The back box must be installed with the front edge flush with the finished surface.

2.

Secure supply ground wire under green ground screw in back box.

3.

Slide supply wiring under retaining straps in back box to hold in place.

4.

Insert wiring plug from heater/fan assembly into socket in back box.

Figure 1

5.

Fit heater/fan assembly into back box and secure in place with (2) screws provided through the center slots in the fan assembly.

2

NOTE: Use the screws provided by the factory to install fan deck to the back box.

INDICATOR

LIGHT

Figure 3

INSTALLATION OF FRONT COVER (GRILLE) AND

THERMOSTAT KNOB

1.

Position the front cover so the four (4) holes on the side align with the tabs on the plastic pieces of the heat deck.

2.

Hook the front cover over the tabs on one side then rotate the front cover into place making sure that all four tabs are snapped onto the front cover.

3.

Fit the thermostat knob onto the thermostat shaft and push into place.

HEATER CHECKOUT AND OPERATION

1.

After heater is completely assembled, push the disconnect switch to the “on” position and rotate thermostat knob counterclockwise until control stops. This is the minimum heat setting.

2.

Turn power supply to heater “ON” at main switch panel.

3.

Heater should not operate. If it operates, disconnect power and re-check wiring.

4.

Rotate thermostat clockwise until it stops (maximum heat setting) and wait at least 2 minutes. Fan control will delay fan coming on until element is warm.

5.

If heater and fan do not come on, disconnect power and check wiring.

6.

Allow heater to continue to operate until room temperature reaches desired comfort level. Then rotate thermostat knob counterclockwise slowly until thermostat clicks off. Fan will continue to operate for a minute or so until element cools.

7.

It may be necessary to readjust thermostat a time or so until exact comfort level is attained. Rotation in the clockwise direction will increase the amount of time the heater will produce heat. Rotation in the counterclockwise direction will reduce the amount of time the heater is on.

NOTE: For best results, the heater should be left “ON” constantly during the heating season as the thermostat, when properly set, will maintain the desired temperature. In the full counter-clockwise position the heater will remain off until the room temperature drops well below freezing.

Figure 4

MAINTENANCE AND CLEANING

Your heater is designed for years of trouble-free operation and requires no special maintenance other than occasional cleaning. The motor is permanently lubricated.

Once each year, the heater should be cleaned to remove dust and other foreign material which has collected during the heating season, as follows:

1.

Turn power off at main switch.

2.

Remove thermostat knob.

3.

Remove front cover by depressing plastic tabs with a flat bladed screwdriver as shown in Figure 4. Release both tabs on one side then rotate cover off of heater assembly.

4.

Use vacuum cleaner with brush attachment to remove dust and dirt that has accumulated in heater (especially around element and fan blade). Do not use water or any cleaners to clean heater components.

5.

Replace grille and thermostat knob.

6.

Wipe grille clean with a damp cloth. DO NOT use waxes or any cleaners that leave a residue since these may discolor during heater operation.

7.

Turn the main line switch on at the switch panel to restore power to heater. The heater is now ready for another season of operation.

OPERATIONAL NOTICE

Your heater is equipped with an automatic reset high limit control that will automatically turn the heater off to prevent a fire if the heater overheats. Should this occur, the indicator light will illuminate and will continue to shine until the limit resets.

!

CAUTION

THE ILLUMINATED INDICATOR LIGHT SIGNIFIES THE HEATER

HAS BEEN SUBJECTED TO SOME ABNORMAL CONDITION.

CHECK HEATER TO INSURE THAT IT HAS NOT BEEN BLOCKED IN

ANY MANNER (IF SO, REMOVE BLOCKAGE). IF THERE IS NO

INDICATION OF BLOCKAGE, IT IS RECOMMENDED THE HEATER

BE CHECKED BY A REPUTABLE ELECTRICIAN OR REPAIR SER-

VICE TO INSURE THE HEATER HAS NOT BEEN DAMAGED.

3

Specifications

MODEL

NO.

VOLTS AMPS

SRA1012DSB

SRA1512DSB

SRA1812DSB

120

120

120

8.40

4.20

12.50

6.25

15.0

WATTS

1000

500

1500

750

1800

IMPORTANT INFORMATION

BTU/HR

3413

1706

5120

2560

6143

WIRE

SIZE

14AWG

12AWG

12 AWG

SRA2024DSB

SRA2027DSB

240

208

277

240

8.40

4.20

7.30

3.61

7.30

3.61

6.25

3.20

2000

1000

1500

750

2000

1000

1500

750

6826

3413

5120

2560

6826

3413

5120

2560

14AWG

14AWG

SRA1527DSB

SRA****IF

SRBB

SRASM

SRAS2

SRAS1

SRADS

SRAFCTP

277

240

5.5

2.75

4.7

2.35

1500

750

1125

562

Inner Frame (Fan Deck Assembly & Grille) Only

5120

2560

3840

1920

14AWG

Back Box Only - For All Above Heaters

Surface Mounting Frame (Accessory) Order Separately

12-1/2”H X 10-3/8”W X 4”D

2” Recess Mounting Frame (Accessory) Order Separately

12-1/2”H X 10-3/8”W X 2”D

1”Recess Mounting Frame (Accessory) Order Separately

12-1/2”H X 10-3/8”W X 1”D

20 Amp-2 Pole Disconnect Switch Kit (Accessory) Order Separately

Tamper Proof Front Cover (Accessory Order Separately)

MODEL NO.

NAMEPLATE

SRA2024DSB

DATE CODE

0695

SMALL ROOM FAN FORCED HEATERS

2000/1000W @ 240VAC 60HZ

1500/750W @ 208VAC 60HZ

MUST BE USED WITH SR-BB BACK BOX.

774G LISTED

ROOM HEATER

DO NOT OPERATE WITHOUT SR-FC

SERIES FRONT COVER IN PLACE.

MARLEY ENGINEERED PRODUCTS

BENNETTSVILLE, SC 29512 399726043

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center.Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered

Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. AND ALL IMPLIED WARRANTIES OF MER-

CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY

DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUEN-

TIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CON-

TRACT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328.

Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley

Engineered Products. When requesting return authorization, include all catalog numbers shown on the products.

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center tollfree by calling 1-800-642-HEAT.

When ordering repair parts, always give the information listed as follows:

1. The Part Number

2. The Model Number

3. The Part Description

4. Date of Manufacture

Part No. 5200-2181-005

ECR 35194

03-02

4

SPX Corporation

470 Beauty Spot Rd. East

Bennettsville, SC 29512 USA

advertisement