TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity Indoor Model No. Product Code No. 7,500BTU / h CS-MKE7NKU 1 852 360 99 9,000BTU / h CS-MKE9NKU 1 852 361 00 11,900BTU / h CS-MKE12NKU 1 852 361 01 17,500BTU / h CS-MKE18NKU 1 852 361 02 24,200BTU / h CS-MKE24NKU 1 852 361 03 Wall Mounted Type Indoor Unit < Applicable Multi-Outdoor Units > CU-3KE19NBU (3-room multi unit) CU-4KE24NBU (4-room multi unit) CU-4KE31NBU (4-room multi unit) AIR CONDITIONER CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU IMPORTANT These air conditioners employ new refrigerant R410A. AIR CONDITIONER CS-MKE18NKU CS-MKE24NKU Pay special attention when servicing the unit. REFERENCE NO. SM700874 SAFETY PRECAUTIONS • Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequences if not performed correctly. Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them. • Symbol Indication : This symbol indicates items to which we need to pay attention. In this triangle, a definite precautionary item is described. : This symbol indicates the item to be prohibited. In or close to this circle, a prohibited item is described. : This symbol indicates the items requiring special attention or instruction. In or close to this circle, a prohibited item is described. • After doing repair work, perform a test run to confirm that there are no abnormalities. At the same time, explain the precautions in use to the user. Warning Before performing an overhaul, disconnect the power plug or power cable from the unit. Performing the work with the power supplied to the unit, may cause an electric shock. When repair work or circuit inspection that requires power supply for the air conditioner, is to be performed, do not touch the charging section. Doing so may cause an electric shock. Prohibit For the step-up capacitor attached to the electric section, perform the repair work after sufficiently discharging it. Insufficient capacitor discharge may cause an electric shock. Do not perform repair work on the electric sections with wet hands. Doing so may cause an electric shock. Prohibit Do not start or stop the air conditioner by means of connecting or disconnecting the power plug. Doing so may cause an electric shock or fire. Prohibit When conducting repair work only use components included in the parts list for the corresponding unit and perform the work with the appropriate tools. Incorrect or poor repair work may cause an electric shock or fire. Never modify the unit. Doing so may cause an electric shock or fire. Prohibit Perform all electric work according to local applicable regulations related to electrical equipment or interior wiring regulation and make sure to use the exclusive circuit. Insufficient capacity to the electric circuit or defective arrangement results may cause an electric shock or fire. Make sure to replace any power cable or lead wire showing any signs of scratch or deterioration. Failure to do so may cause an electric shock, overheating or fire. Make sure that there is no dust on or slack in the power plug and insert fully into the socket. Dust or incomplete connections may cause an electric shock or fire. Do not damage or process the power cord, as it may cause an electric shock or fire. Prohibit For the wiring between the indoor unit and outdoor unit, securely fix the specified cable onto the terminal plate. Poorly fixed wiring may cause a heat or fire. After connecting the wiring between the indoor unit and outdoor unit, attach the terminal cover securely. Incomplete attachment of the terminal cover may cause overheating or fire. 2 Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." Prohibit When the welded section of the compressor intake or discharge pipe is to be disconnected, perform it in a well-ventilated place after sufficiently recovering the refrigerant gas. Any residue gas may jet out refrigerant or refrigerating machine oil, which may cause an injury. When the work is to be performed in a high place (About 2 meters or more), make sure to wear a safety helmet, gloves and safety belt. Insufficient safety gear may cause a serious injury in case of a fall. When the unit is to be relocated, confirm that the new installation location has sufficient strength for the weight of the unit. Insufficient strength of the installation location and incomplete installation work may cause an injury due to the unit falling. When the remote controller batteries are replaced, dispose of the old batteries out of the reach of children. If a child swallows a battery, make sure that the child gets immediate medical attention. Caution Do not wash the air conditioner with water, as this may cause an electric shock or fire. Prohibit For the repair work in places with high humidity or moisture, make sure to ground the unit. Failure to do so may cause an electric shock. Confirm that the component attachment position, wiring condition, soldering condition and connector connection are normal. If not, it may cause overheating or fire. Confirm that the temperature around the compressor is not too high, and then perform the repair work. Failure to do so may cause a burn. Perform welding work in a place with good ventilation. If the work is performed in a poorly ventilated area, it might cause a lack of oxygen. If the installation plate or attachment frame has deteriorated due to corrosion, etc., replace it. Failure to do so may cause an injury due to the unit falling. When the cleaning is to be performed, make sure to turn off the power and pull out the plug. Touching the fan that is rotating at high speed may result in an injury. When the indoor unit is to be removed, do not place it on an incline. Doing so may cause wet furniture because water left inside may trickle down. Prohibit Do not hold the sharp end of the unit or the aluminum fins, as it may cause an injury to your hand or finger. Prohibit After repairs, make sure to measure the insulation resistance and confirm that the value is 1 Mohm or more. Any insulation error may cause an electric shock. After repairs, make sure to check the drainage of the indoor unit. Inappropriate drainage may cause wet furniture and floors due to water leakage. 3 Table of Contents Page SAFETY PRECAUTIONS ............................................................................................................. 2 TABLE OF CONTENTS .................................................................................................................... 4 ................................................................................... 5 1. OPERATING RANGE ................................................................................................................... 6 APPLICABLE MULTI-OUTDOOR UNITS 2. SPECIFICATIONS 2-1. Unit Specifications ............................................................................................................. 7 2-2. Major Component Specifications ....................................................................................... 17 2-3. Other Component Specifications ....................................................................................... 22 3. DIMENSIONAL DATA .................................................................................................................... 23 4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram .................................................................................................. 25 5. PERFORMANCE DATA 5-1. Air Throw Distance Charts ................................................................................................. 26 6. ELECTRICAL DATA 6-1. Electric Wiring Diagrams .................................................................................................... 31 7. FUNCTIONS 7-1. Operation Functions ........................................................................................................... 32 7-2. Protective Functions ........................................................................................................... 34 8. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 8-1. Precautions before Performing Inspection or Repair .......................................................... 8-2. Method of Self-Diagnostics ................................................................................................. 8-3. Checking the Indoor and Outdoor Units .............................................................................. 8-4. Trouble Diagnosis of Fan Motor .......................................................................................... 8-5. Noise Malfunction and Electromagnetic Interference .......................................................... 35 35 38 41 42 APPENDIX A Operating Instructions .......................................................................................... A-1 APPENDIX B Operating Instructions .......................................................................................... A-2 APPENDIX C INSTALLATION INSTRUCTIONS .......................................................................... A-3 4 APPLICABLE MULTI-OUTDOOR UNITS Multi-Outdoor Unit 3-Room 4-Room 4-Room CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU CS-MKE7NKU YES YES YES CS-MKE9NKU YES YES YES CS-MKE12NKU YES YES YES CS-MKE18NKU YES YES YES CS-MKE24NKU NO YES YES Indoor Unit 5 1. OPERATING RANGE Temperature Cooling Heating Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115° F DB Minimum 67 °F DB / 57 °F WB 14° F DB Maximum 80 °F DB / 67 °F WB 75° F DB / 65 °F WB Minimum – DB / – WB – DB / 0 °F WB 6 2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit CS-MKE7NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Heating 8,500 2.50 271(460) / 241(410) / 218(370) - Cooling Heating 187 to 253 V A W 0.11 25 0.11 25 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 33 / 30 / 27 / 23 33 / 30 / 27 / 23 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Cooling 7,500 2.20 241(410) / 224(381) / 212(360) 2.77 Flare Type 1/4 (6.35) 3/8 (9.52) Optional 11-7/32 32-15/32 7-7/16 10-19/32 35-21/32 14-1/32 19.8 24.3 2.82 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (285) (825) (189) (269) (906) (356) (9.0) (11.0) (0.08) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 7 Indoor Unit CS-MKE7NKU < 208V > Type Wall Mounted Type Indoor Unit 208V Single-Phase 60Hz Voltage Rating Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Heating 8,500 2.50 271(460) / 241(410) / 218(370) - Cooling Heating 187 to 253 V A W 0.12 25 0.12 25 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 33 / 30 / 27 / 23 33 / 30 / 27 / 23 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Cooling 7,500 2.20 241(410) / 224(381) / 212(360) 2.77 Flare Type 1/4 (6.35) 3/8 (9.52) Optional 11-7/32 32-15/32 7-7/16 10-19/32 35-21/32 14-1/32 19.8 24.3 2.82 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (285) (825) (189) (269) (906) (356) (9.0) (11.0) (0.08) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 8 Indoor Unit CS-MKE9NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Heating 12,200 3.60 282(479) / 271(460) / 218(370) - Cooling Heating 187 to 253 V A W 0.15 35 0.15 35 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 34 / 31 / 28 / 23 34 / 31 / 28 / 23 Indoor Horizontal Vertical Air Filter Refrigerant Indoor : Hi/Me/Lo/Qt* dB-A Operation Sound (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Cooling 9,000 2.65 259(440) / 241(410) / 212(360) 3.4 Flare Type 1/4 (6.35) 3/8 (9.52) Optional 11-7/32 32-15/32 7-7/16 10-19/32 35-21/32 14-1/32 19.8 24.3 2.82 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (285) (825) (189) (269) (906) (356) (9.0) (11.0) (0.08) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 9 Indoor Unit CS-MKE9NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 9,000 2.65 259(440) / 241(410) / 212(360) 3.4 Heating 12,200 3.60 282(479) / 271(460) / 218(370) - Cooling Heating 187 to 253 V A W 0.17 35 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 34 / 31 / 28 / 23 34 / 31 / 28 / 23 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.17 35 Flare Type 1/4 (6.35) 3/8 (9.52) Optional 11-7/32 32-15/32 7-7/16 10-19/32 35-21/32 14-1/32 19.8 24.3 2.82 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (285) (825) (189) (269) (906) (356) (9.0) (11.0) (0.08) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 10 Indoor Unit CS-MKE12NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 11,900 3.50 282(479) / 259(440) / 218(370) 4.26 Heating 14,300 4.20 294(500) / 271(460) / 218(370) - Cooling Heating 187 to 253 V A W 0.15 35 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 36 / 33 / 29 / 25 34 / 31 / 29 / 25 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.15 35 Flare Type 1/4 (6.35) 3/8 (9.52) Optional 11-7/32 32-15/32 7-7/16 10-19/32 35-21/32 14-1/32 19.8 24.3 2.82 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (285) (825) (189) (269) (906) (356) (9.0) (11.0) (0.08) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 11 Indoor Unit CS-MKE12NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 11,900 3.50 282(479) / 259(440) / 218(370) 4.26 Heating 14,300 4.20 294(500) / 271(460) / 218(370) - Cooling Heating 187 to 253 V A W 0.17 35 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 36 / 33 / 29 / 25 34 / 31 / 29 / 25 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.17 35 Flare Type 1/4 (6.35) 3/8 (9.52) Optional 11-7/32 32-15/32 7-7/16 10-19/32 35-21/32 14-1/32 19.8 24.3 2.82 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (285) (825) (189) (269) (906) (356) (9.0) (11.0) (0.08) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 12 Indoor Unit CS-MKE18NKU < 230V > Type Wall Mounted Type Indoor Unit 230V Single-Phase 60Hz Voltage Rating Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 17,500 5.15 500(850) / 447(760) / 377(641) 4.89 Heating 20,400 6.00 500(850) / 435(739) / 377(641) - Cooling Heating 187 to 253 V A W 0.15 35 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 41 / 38 / 34 / 28 40 / 37 / 34 / 28 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.15 35 Flare Type 1/4 (6.35) 1/2 (12.7) Optional 11-23/32 41-15/16 8-5/8 11-27/32 45-1/8 15-5/32 26.5 33.1 4.59 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (298) (1,065) (219) (301) (1,146) (385) (12.0) (15.0) (0.13) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 13 Indoor Unit CS-MKE18NKU < 208V > Type Wall Mounted Type Indoor Unit 208V Single-Phase 60Hz Voltage Rating Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 17,500 5.15 500(850) / 447(760) / 377(641) 4.89 Heating 20,400 6.00 500(850) / 435(739) / 377(641) - Cooling Heating 187 to 253 V A W 0.17 35 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 41 / 38 / 34 / 28 40 / 37 / 34 / 28 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.17 35 Flare Type 1/4 (6.35) 1/2 (12.7) Optional 11-23/32 41-15/16 8-5/8 11-27/32 45-1/8 15-5/32 26.5 33.1 4.59 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (298) (1,065) (219) (301) (1,146) (385) (12.0) (15.0) (0.13) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 14 Indoor Unit CS-MKE24NKU < 230V > Type Wall Mounted Type Indoor Unit 230V Single-Phase 60Hz Voltage Rating Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 24,200 7.10 541(919) / 500(850) / 435(739) 4.89 Heating 29,000 8.50 541(919) / 488(829) / 435(739) - Cooling Heating 187 to 253 V A W 0.20 45 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 44 / 41 / 38 / 30 43 / 40 / 37 / 30 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.20 45 Flare Type 1/4 (6.35) 5/8 (15.88) Optional 11-23/32 41-15/16 8-5/8 11-27/32 45-1/8 15-5/32 26.5 33.1 4.59 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (298) (1,065) (219) (301) (1,146) (385) (12.0) (15.0) (0.13) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 15 Indoor Unit CS-MKE24NKU < 208V > Type Wall Mounted Type Indoor Unit 208V Single-Phase 60Hz Voltage Rating Performance Capacity Air Circulation (Hi/Me/Lo) Moisture Removal (High) Electrical Rating Available Voltage Range Running Amperes Power Input Features Control / Temperature Control Control Unit Timer Fan Speeds Airflow Direction (Indoor) BTU/h kW ft3/min (m3/h) Pints/h Cooling 24,200 7.10 541(919) / 500(850) / 435(739) 4.89 Heating 29,000 8.50 541(919) / 488(829) / 435(739) - Cooling Heating 187 to 253 V A W 0.22 45 Microprocessor / I.C. Thermistor Wireless Remote Control Unit 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps Manual Auto Washable, Anti-Mold R410A 44 / 41 / 38 / 30 43 / 40 / 37 / 30 Indoor Horizontal Vertical Air Filter Refrigerant Operation Sound Indoor : Hi/Me/Lo/Qt* dB-A (*Qt = Quiet mode) Refrigerant Tubing Connections Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tubing Kit Dimensions & Weight Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping 0.22 45 Flare Type 1/4 (6.35) 5/8 (15.88) Optional 11-23/32 41-15/16 8-5/8 11-27/32 45-1/8 15-5/32 26.5 33.1 4.59 inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m3) (298) (1,065) (219) (301) (1,146) (385) (12.0) (15.0) (0.13) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 16 2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit CS-MKE7NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-MKE7NKU Microprocessor 250V 3A Fan Type Q'ty ... Dia. and Length Cross-Flow 1 ... D3-5/8 / L24-31/32 (D92/L634) inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 °F (25 °C)) DC Motor SIC-41CVJ-D847-4 ... 1 8 1,050 / 1,100 47 - W Ohm Internal Controller Yes Yes - Micro F VAC Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal : 400 +/- 7% ft2 (m2) Aluminum Plate Fin / Copper Tube 2 19.5 2.02 (0.188) Heat Exchanger Coil Coil Rows Fins per inch Face Area DATA SUBJECT TO CHANGE WITHOUT NOTICE. 17 Indoor Unit CS-MKE9NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-MKE9NKU Microprocessor 250V 3A Fan Type Q'ty ... Dia. and Length Cross-Flow 1 ... D3-5/8 / L24-31/32 (D92/L634) inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 °F (25 °C)) DC Motor SIC-41CVJ-D847-4 ... 1 8 1,100 / 1,150 47 - W Ohm Internal Controller Yes Yes - Micro F VAC Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal : 400 +/- 7% ft2 (m2) Aluminum Plate Fin / Copper Tube 2 19.5 2.02 (0.188) Heat Exchanger Coil Coil Rows Fins per inch Face Area DATA SUBJECT TO CHANGE WITHOUT NOTICE. 18 Indoor Unit CS-MKE12NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-MKE12NKU Microprocessor 250V 3A Fan Type Q'ty ... Dia. and Length Cross-Flow 1 ... D3-5/8 / L24-31/32 (D92/L634) inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 °F (25 °C)) DC Motor SIC-41CVJ-D847-4 ... 1 8 1,200 / 1,200 47 - W Ohm Internal Controller Yes Yes - Micro F VAC Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal : 400 +/- 7% ft2 (m2) Aluminum Plate Fin / Copper Tube 2 19.5 2.02 (0.188) Heat Exchanger Coil Coil Rows Fins per inch Face Area DATA SUBJECT TO CHANGE WITHOUT NOTICE. 19 Indoor Unit CS-MKE18NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-MKE18NKU Microprocessor 250V 3A Fan Type Q'ty ... Dia. and Length Cross-Flow 1 ... D3-5/8 / L33-9/32 (D92/L845) inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 °F (25 °C)) DC Motor SIC-41CVJ-D847-3 ... 1 8 1,200 / 1,200 30 - W Ohm Internal Controller Yes Yes - Micro F VAC Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal : 400 +/- 7% ft2 (m2) Aluminum Plate Fin / Copper Tube 2 19.5 3.07 (0.285) Heat Exchanger Coil Coil Rows Fins per inch Face Area DATA SUBJECT TO CHANGE WITHOUT NOTICE. 20 Indoor Unit CS-MKE24NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-MKE24NKU Microprocessor 250V 3A Fan Type Q'ty ... Dia. and Length Cross-Flow 1 ... D3-5/8 / L33-9/32 (D92/L845) inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 °F (25 °C)) DC Motor SIC-41CVJ-D847-3 ... 1 8 1,300 / 1,300 30 - W Ohm Internal Controller Yes Yes - Micro F VAC Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal : 400 +/- 7% ft2 (m2) Aluminum Plate Fin / Copper Tube 2 19.5 3.07 (0.285) Heat Exchanger Coil Coil Rows Fins per inch Face Area DATA SUBJECT TO CHANGE WITHOUT NOTICE. 21 2-3. Other Component Specifications Model No. of sensor Sensor Name PTM-D51HS4-1 TH2 PTM-D51HS4-2 TH2 Indoor air temp sensor Quantity of Sensor CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU 1 1 1 0 0 0 0 0 1 1 10 Resistance (k ohm) 9 8 7 6 5 4 3 2 1 0 50 59 68 77 86 95 104 (10) (15) (20) (25) (30) (35) (40) Temperature °F (°C) Model No. of sensor Sensor Name PTM-D51HS4-1 TH1 PTM-D51HS4-2 TH1 Indoor heat exchanger sensor Quantity of Sensor CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU 1 1 1 0 0 0 0 0 1 1 Resistance (k ohm) 200 180 160 140 120 100 80 60 40 20 0 32 50 68 86 104 122 140 158 176 194 (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature °F (°C) 22 3. DIMENSIONAL DATA Indoor Unit CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Unit: inch(mm) (852-0-0010-215-00-0) 23 Indoor Unit CS-MKE18NKU CS-MKE24NKU Unit: inch(mm) (852-0-0010-216-00-0) 24 4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Indoor unit O.D. 3/8" (9.52 mm) Indoor heat exchanger O.D. 1/4" (6.35 mm) Cooling cycle Heating cycle Indoor Unit CS-MKE18NKU Indoor unit O.D. 1/2" (12.7 mm) Indoor heat exchanger O.D. 1/4" (6.35 mm) Cooling cycle Heating cycle Indoor Unit CS-MKE24NKU Indoor unit O.D. 5/8" (15.88 mm) Indoor heat exchanger O.D. 1/4" (6.35 mm) Cooling cycle Heating cycle 25 5. PERFORMANCE DATA 5-1. Air Throw Distance Charts Indoor Unit Cooling CS-MKE7NKU Room air temp.:80°F (26.7°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 25 30 25 30 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 0° , : Flap angle 30° , Heating : Axis air velocity 0° : Axis air velocity 30° Room air temp.:70°F (21.1°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 45° , : Flap angle 60° , : Axis air velocity 45° : Axis air velocity 60° 26 Indoor Unit Cooling CS-MKE9NKU Room air temp.:80°F (26.7°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 25 30 25 30 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 0° , : Flap angle 30° , Heating : Axis air velocity 0° : Axis air velocity 30° Room air temp.:70°F (21.1°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 45° , : Flap angle 60° , : Axis air velocity 45° : Axis air velocity 60° 27 Indoor Unit Cooling CS-MKE12NKU Room air temp.:80°F (26.7°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 25 30 25 30 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 0° , : Flap angle 30° , Heating : Axis air velocity 0° : Axis air velocity 30° Room air temp.:70°F (21.1°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 45° , : Flap angle 60° , : Axis air velocity 45° : Axis air velocity 60° 28 Indoor Unit Cooling CS-MKE18NKU Room air temp.:80°F (26.7°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 25 30 25 30 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 0° , : Flap angle 30° , Heating : Axis air velocity 0° : Axis air velocity 30° Room air temp.:70°F (21.1°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 45° , : Flap angle 60° , : Axis air velocity 45° : Axis air velocity 60° 29 Indoor Unit Cooling CS-MKE24NKU Room air temp.:80°F (26.7°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 25 30 25 30 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 0° , : Flap angle 30° , Heating : Axis air velocity 0° : Axis air velocity 30° Room air temp.:70°F (21.1°C) Fan speed:High Horizontal distance (ft.) 0 5 10 15 20 Axis air velocity (ft./sec.) Vertical distance (ft.) 0 5 10 15 : Flap angle 45° , : Flap angle 60° , : Axis air velocity 45° : Axis air velocity 60° 30 6. ELECTRICAL DATA 6-1. Electric Wiring Diagrams CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU TERMINAL BASE BLK WHT RED 1 2 3 4 5 SI 1 2 3 FLAP LAMP 5P (WHT) 4 10P (WHT) 5 FLAP MOTOR 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 RED WHT WHT WHT WHT WHT WHT WHT WHT WHT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 IND LAMP ASSY AC1 AC2 CONNECTOR 1 1 RED 2 2 PNK 3 3 BLU FLAP 4 4 BRN 5 5 YEL 1 2 3 TO OUTDOOR UNIT EVAPORATOR GRN/YEL Indoor Unit CONTROLLER ROOM THERMISTOR RED FM BLK WHT YEL BLU 1 2 3 4 5 6 1 1 1 2 ROOM/COIL 2 2 4P (WHT) 3 3 3 DCM 4 4 4 6P (BLU) 5 6 BLK BLK BLK BLK COIL THERMISTOR FAN MOTOR HA JEM-A 4P (WHT) 1 2 3 4 8FA2-5251-11000-2 31 7. FUNCTIONS 7-1. Operation Functions Emergency operation SENSOR DRY Emergency operation is available when the remote controller malfunctions, has been lost, or otherwise cannot be used. During DRY operation, the system adjusts the room temperature and fan speed according to the conditions in the room, in order to maintain a comfortable room environment. To operate the system, press the OPERATION button, which is also used as the receiver, below the unit display. Each time this button is pressed, the OPERATION lamp changes color to indicate the type of operation. Select the desired type of operation. COOL HEAT STOP (GREEN) (RED) (Lamp Off) SENSOR DRY operation DRY operation is as shown in the figure below. Load COOL zone A zone B zone The set temperature is 4°F(2°C) below the detected room temperature in the case of cooling operation, and 4°F(2°C) above the room temperature in the case of heating operation. The flap and fan speed settings are AUTO. Conditions are monitored at all times when the room temperature is below 59°F(15°C). DRY A The compressor operation frequency varies. The indoor fan operates with 1/f fluctuation. Auto Initial Operation Mode Selection Selecting the operation mode DRY B When AUTO mode is selected, the microprocessor calculates the difference between the set temperature and the room temperature, and automatically switches to Cooling or Heating mode. Room temp. Set temp. COOL Room temp. Set temp. HEAT The compressor operates at a low operating frequency. The indoor fan operates with 1/f fluctuation. Monitor Monitoring operation takes place when the room temperature is below 59°F(15°C), or more than 5°F(3°C) below the set temperature. When the monitoring range is entered, the compressor stops, and the indoor fan operates with 1/f fluctuation. Once the mode is selected based on this function, the unit will continuously operate at the same mode as initially selected. NOTE When multiple indoor units are used and units in other rooms are already operating, they will be set to the same mode of operation as the operating indoor units. PAM- control In order to further improve inverter performance, control is switched between PWM control at low operation speeds, and PAM control at high operation speeds, making the most effective use of power. 32 HIGH POWER NIGHT SETBACK This function acts to raise the power but keeps the AC system in the same operating mode. This function is set with the HIGH POWER button on the remote controller. (It can be set regardless of the temperature and fan speed settings.) When NIGHT SETBACK operation is set, the temperature and fan speed settings will be adjusted automatically to allow comfortable sleep. When NIGHT SETBACK operation is set, " mark" appears on the remote controller. The main unit display lamp also becomes dimmer. HIGH POWER operation from remote controller The unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above "High." COOL and DRY modes When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2°F(1°C) when 30 minutes have passed after the selection was made, and then another 2°F(1°C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed. Frequency MAX Setting temperature Time 0 30 min. Start 5 min. Press the NIGHT SETBACK button End NOTE When HIGH POWER operation ends, the unit operates at low Hz for 5 minutes, regardless of the thermostat OFF conditions. When in DRY mode, operation is in the cooling zone. OPERATION lamp Red Orange Green Red and Orange alternately TIMER lamp Green QUIET lamp Green 2°F(1°C) 30 min. 30 min. Time HEAT mode When the night setback mode is selected, the air conditioner automatically lowers the temperature setting 4°F(2°C) when 30 minutes have passed after the selection was made, and then another 4°F(2°C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle heating is needed. Lamp colors HEAT operation DRY operation COOL operation DEFROSTING operation 2°F(1°C) Setting temperature Press the NIGHT SETBACK button Timer backup Operation stops if there are no operator controls for 25 hours or longer after unit operation switched from OFF to ON by use of ON timer operation. 33 4°F(2°C) 4°F(2°C) 30 min. 30 min. Time 7-2. Protective Functions Overload prevention during heating Cold-air prevention during heating Indoor heat exchanger temperature °F(°C) During HEAT operation, the temperature of the indoor heat exchanger is used to control the frequency and lessen the load on the compressor before the protective device is activated. Indoor heat exchanger A. Control start B. Control end A T1 During heating, the fan speed is set to "LL" (very low) or stopped. As the temperature of the indoor heat exchanger rises, the fan speed is changed to the set speed. At stability of operation B T2 a b c d At start of operation a. Area: Automatic capacity control b. When Point A has been exceeded, the operation frequency is LL reduced by a certain proportion. c. Area: Frequency increase is prohibited. d. At Point B and below, overload prevention is ended and control is the same as in the a area. NOTE The operation temperature shown as T1 and T2 in the chart left differ by models. CS-KE7NKU CS-KE9NKU CS-KE12NKU CS-KE18NKU CS-KE24NKU T1 127(53) 124(51) T2 117(47) 113(45) Stopped Indoor heat exchanger temperature °F (°C) C A B 36 (2) * a b c Approx. 104 (40) • The fan speed is forcibly changed to "LL" beginning 30 seconds after the thermostat turns OFF. • At stability of operation refers to operation when the room temperature has approached the set temperature. • When HEAT operation starts, the indoor fan is stopped until the temperature of the indoor heat exchanger reaches 68°F(20°C) or higher, or until the room temperature reaches 59°F(15°C) or higher. During COOL or DRY operation, freezing is detected and operation is stopped when the temperature of the indoor heat exchanger matches the conditions below. 1. Freeze-prevention operation is engaged when the temperature of the indoor heat exchanger is below 43°F(6°C). 2. Restart after freeze-prevention operation occurs when the temperature of the indoor heat exchanger reaches 46°F(8°C) or above. 43 (6) 86 (30) NOTE Freeze prevention 46 (8) 77 (25) Indoor heat exchanger temperature °F(°C) °F(°C) d a. Area: Automatic capacity control b. When the temperature drops below Point A, the operation frequency is reduced by a certain proportion. c. Area: Frequency increase is prohibited. d. When the temperature reaches Point C or above, freezing prevention is ended and control is the same as in the a area. * Set fan speed High When the temperature drops to below 36°F(2°C) (continuously for 2 minutes or longer), the compressor stops. Once the freeze condition is detected, the air conditioner will work less than the maximum frequency until it is turned off. 34 8. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 8-1. Precautions before Performing Inspection or Repair After checking the self-diagnostics monitor, turn the power OFF before starting inspection or repair. High-capacity electrolytic capacitors are used inside the outdoor unit controller (inverter). They retain an electrical charge (charging voltage DC 310V) even after the power is turned OFF, and some time is required for the charge to dissipate. Be careful not to touch any electrified parts before the controller LED (red) turns OFF. If the outdoor controller is normal, approximately 30 seconds will be required for the charge to dissipate. However, allow at least 5 minutes for the charge to dissipate if there is thought to be any trouble with the outdoor controller. 8-2. Method of Self-Diagnostics < Clock display > Follow the procedure below to perform detailed trouble diagnostics. Test run mode Self-diagnostics mode NOTE 1: If the operation lamp blinks every 0.5 seconds immediately when the power is turned ON, there is an external ROM (OTP data) failure on the indoor circuit board, or a ROM socket insertion problem, or the ROM has not been installed. 2: The failure mode is stored in memory even when the power is not ON. Follow the procedure below to perform diagnostics. PROCEDURE After turning on power to the air conditioner, use the remote controller and follow the steps below to execute self-diagnostics. Step 1: Press and hold the remote controller QUIET button and 1 HR TIMER button. At the same time, press the ACL (reset) button. Use a pointed object such as the tip of a pen to press the ACL button. When this has been done, "oP-1" (test run) appears, blinking, in the remote controller clock display area. Step 2: Next, press the 1 HR TIMER button once to change the display from "oP-1" to "oP-3" (self-diagnostics). (The display continues to blink.) Step 3: Finally press the ON/OFF button to engage self-diagnostics mode. • The self-diagnostics function utilizes the 3 indicator lamps on the main unit, in combinations of ON lamps, blinking lamps, and OFF lamps, to report the existence of sensor trouble or a protective operation. (The lamps blink or remain ON for 5 seconds, then turn OFF for 2 seconds.) Self-diagnostics is completed when the buzzer sounds 3 short beeps. • A maximum of 3 self-diagnostics reports are displayed, for 5 seconds each, beginning with the most recent report. Following this display the lamps turn OFF. In order to view the self-diagnostics results again, press the ON/OFF button again. • The 3 lamps remain OFF if no trouble has occurred. <IMPORTANT> After self-diagnostics is completed, be sure to press the ACL (reset) button to return to normal mode. The air conditioner will not operate if this is not done. 35 QUIET button ON/OFF operation button 1HR. TIMER button ACL (Reset) button (1) Self-diagnostics Lamps INDOOR UNIT (1) OPERATION lamp (2) TIMER lamp (3) QUIET lamp OPERATION button REMOTE CONTROL receiver Since the indications cover various units, the corresponding parts listed below may not be present in some models. .... OFF INDICATION ON INDOOR UNIT QUIET (3) TIMER (2) OPERATION (1) CODE S01 S02 S03 S04 S05 DIAGNOSIS CONTENTS POSSIBLE MALFUNCTION COMPRESSOR TEMP. SENSOR TROUBLE (1) OPEN OR SHORT CIRCUIT IN SENSOR (2) POOR CONTACT AT CONNECTOR OR OPEN CIRCUIT AT O/D HEAT EXCHANGER TERMINAL PRESS-FIT LOCATION TEMP. SENSOR TROUBLE (3) O/D PCB FAILURE (O/D = OUTDOOR) O/D AIR TEMP. SENSOR TROUBLE S07 O/D CURRENT SENSOR ERROR E02 .... ON ROOM TEMP. SENSOR TROUBLE (1) OPEN OR SHORT CIRCUIT IN SENSOR (2) POOR CONTACT AT CONNECTOR OR OPEN CIRCUIT AT I/D HEAT EXCHANGER TERMINAL PRESS-FIT LOCATION (FOR HUMIDITY SENSOR, TEMP. SENSOR TROUBLE THIS REPRESENTS SHORT-CIRCUIT DETECTION ONLY.) (3) I/D PCB FAILURE (I/D = INDOOR) HUMIDITY SENSOR TROUBLE S06 E01 .... BLINKING O/D PCB FAILURE (1) MIS-WIRING (2) AC POWER FAILURE (3) BLOWN FUSE I/D-O/D COMMUNICATION TROUBLE (4) POWER RELAY FAILURE (5) I/D OR O/D PCB FAILURE (SERIAL COMMUNICATION TROUBLE) (6) O/D FAN MOTOR FAILURE (7) REACTOR FAILURE (8) HIGH-PRESSURE SW FAILURE (9) OLR FAILURE (10) MAGNETIC COIL FAILURE (1) HIC OR POWER TR FAILURE (2) O/D FAN NOT OPERATING (3) INSTANTANEOUS POWER STOPPAGE (4) SERVICE VALVE NOT OPENED. HIC CIRCUIT TROUBLE (5) O/D FAN BLOCKED (6) CONTINUOUS OVERLOAD OPERATION POWER TR CIRCUIT TROUBLE (7) COMPRESSOR FAILURE (8) O/D PCB FAILURE E03 O/D UNIT EXTERNAL ROM TROUBLE (1) EXTERNAL ROM DATA FAILURE (2) O/D PCB FAILURE E04 CURRENT PEAK CUT E05 PAM CIRCUIT TROUBLE ACTIVE CIRCUIT TROUBLE E06 COMPRESSOR DISCHARGE TEMP. OVERHEATING PREVENTION E07 I/D FAN OPERATION TROUBLE E08 4-WAY VALVE SWITCHING TROUBLE ZERO-CROSS TROUBLE (1) 4-WAY VALVE FAILURE (HEAT PUMP MODEL ONLY) (2) O/D PCB FAILURE E09 GAS-LOSS PREVENTION (1) SERVICE VALVE NOT OPENED (2) INSUFFICIENT GAS E10 DC COMPRESSOR DRIVE CIRCUIT TROUBLE (1) OPEN PHASE (2) O/D PCB FAILURE E11 (1) FAN MOTOR FAILURE (2) CONNECTOR CONTACT FAILURE O/D DC FAN OPERATION TROUBLE (3) O/D PCB FAILURE E12 O/D SYSTEM COMM FAILURE, OLR OPERATION, O/D POWER OPEN PHASE, O/D FREEZING E13 (1) I/D FAN SYSTEM FAILURE (2) INSUFFICIENT GAS FREEZING-PREVENTION OPERATION (3) OPERATION AT LOW TEMPERATURE (1) INSTANTANEOUS POWER STOPPAGE (2) HIC OR POWER TR FAILURE (3) O/D PCB FAILURE (1) O/D PCB FAILURE (2) O/D POWER VOLTAGE TROUBLE (1) ELECTRIC EXPANSION VALVE FAILURE (2) CHOKED CAPILLARY TUBE (3) INSUFFICIENT GAS (4) CONTINUOUS OVERLOAD OPERATION (5) O/D FAN NOT OPERATING (6) O/D PCB FAILURE (1) FAN MOTOR FAILURE (2) CONNECTOR CONTACT FAILURE (3) I/D PCB FAILURE (1) MIS-WIRING (2) BLOWN FUSE (3) POWER RELAY FAILURE (4) O/D PCB FAILURE (5) COMPRESSOR FAILURE 8FA2-5251-11100-2 36 (2) If the self-diagnostics function fails to operate Check the indoor unit. No indicators illuminate and the indoor fan does not rotate. Check the power voltage. Blown Is the fuse blown? Normal Replace the circuit board or the fuse. Replace the controller. 37 8-3. Checking the Indoor and Outdoor Units (1) Checking the indoor unit No. 1 Control Use the remote controller to operate the unit in "TEST run" mode. To determine whether the mode is currently in "TEST run" mode, check the 4 indicator lamps on the unit. If all 4 are blinking, the current mode is "TEST run." Check items (unit operation) • The rated voltage must be present between inter-unit wirings 1 and 2. • Connect a 5 k ohm resistor between inter-unit wirings 2 and 3. When the voltage at both ends is measured, approximately 12 to 15V DC must be output and the multimeter pointer must bounce once every 8 seconds. Or instead of measuring the voltage, you can insert an LED jig and check that the LED flickers once every 8 seconds. If there are no problems with the above, then check the outdoor unit. For the "Test run" procedure, refer to "4. How to Test Run the Air Conditioner" on Appendix B. (2) Checking the outdoor unit No. Control Check items (unit operation) 1 Apply the rated voltage between outdoor unit terminals L1 and L2. • The control panel LED (red) must illuminate. 2 Short-circuit the outdoor unit COM terminal to the T-RUN terminal. • The compressor, fan motor, and 4-way valve must all turn on. If there are no problems with the above, then check the indoor unit. TEST/T-RUN terminals Using the TEST/T-RUN terminals T-RUN : Test run (compressor and fan motor turn ON). TEST/MV : Compresses time to 1/60th (accelerates operation by 60 times faster than normal). (TEST)/MV T-RUN 38 COM (3) How to Identify a Serial Communication Error If the lamps on the main body show the following conditions after the completion of self-diagnosis, a communication error between the indoor unit and outdoor unit might be considered. In such a case, identify the breakdown section by using the following procedure. NOTE Refer to "Method of Self-Diagnosis" for the self-diagnosis procedure. Lamp Condition Quiet Timer Operation (3) (2) (1) : Off : Blinking : Illuminated E01 E12 (3-1) Condition: E01 WARNING For terminal board short circuit work or inter-unit wiring removal, turn off the power to avoid an electric shock. Remove the terminal board short circuit after the completion of self-diagnosis. Operate the air conditioner in the "TEST RUN" mode. Does the voltage between the terminals 1 and 2 on the indoor unit terminal board reach the rated value ? Yes 1. Short-circuit between the terminals 2 and 3 on the indoor unit terminal board. 2. Operate the system in TEST RUN mode. Then, five minutes later, perform the self-diagnosis. No Condition: E12 What is the self-diagnosis result ? 1. Disconnect the inter-unit wiring on the indoor unit side. 2. Operate the system in the "TEST RUN" mode. An error in the P. C. Board in the indoor unit might be considered. Condition: E01 Does the voltage between the wires 1 and 2 of inter-unit wiring on the indoor unit side reach the rated value ? No Yes 1. Disconnect the inter-unit wiring on the outdoor unit side. 2. Short-circuit between the terminals 2 and 3 on the outdoor unit terminal board. 3. Operate the system in TEST RUN mode. Then, five minutes later, perform the self-diagnosis. An error in the P. C. Board in the indoor unit might be considered. (Terminal board error, etc.) An error in the P. C. Board in the outdoor unit might be considered. (Connection error between the P. C. Board in the outdoor unit and J-B) An error in the inter-unit wiring might be considered. (ex. wire breaking or connection error, etc.) Condition: E12 What is the self-diagnosis result ? Condition: E01 An error in the inter-unit wiring might be considered. (ex. wire breaking or connection error, etc.) An error in the P. C. Board in the outdoor unit might be considered. Connection error between the P. C. Board in the outdoor unit and J-B) 39 (3-2) Condition: E12 1. Disconnect the inter-unit wiring on the indoor unit side. 2. Operate the system in TEST RUN mode. Then, five minutes later, perform the self-diagnosis. Condition: E01 What is the self-diagnosis result ? Condition: E12 1. Disconnect the inter-unit wiring on the outdoor unit side. 2. Operate the system in TEST RUN mode. Then, five minutes later, perform the self-diagnosis. An error in the P. C. Board in the indoor unit might be considered. (Terminal board error, etc.) Condition: E01 What is the self-diagnosis result ? Condition: E12 An error in the P. C. Board in the outdoor unit might be considered. (Connection error between the P. C. Board in the outdoor unit and J-B) An error in the inter-unit wiring might be considered. (ex. wire breaking or connection error, etc.) 40 8-4. Trouble Diagnosis of Fan Motor 8-4-1. Indoor Fan Motor This indoor DC fan motor contains an internal control PCB. Therefore, it is not possible to measure the coil resistance, and the following procedure should be used to check the motor. To perform diagnosis, operate the unit in cooling mode with indoor fan speed "High". Next, make sure that the indoor unit receive the signals from the remote controller when the ON/OFF operation button is pressed. Important: (A) Turn OFF the power before connecting or disconnecting the motor connectors. (B) When performing voltage measurement at the indoor controller connector for (3) in the table below, the DC motor will trip and voltage output will stop approximately 1 minute after operation is started. For this reason, to measure the voltage again, turn OFF the unit once using the remote controller, and then start the air conditioner again. [Trouble symptom 1] The fan does not stop when the unit stops. Indoor unit controller trouble. [Trouble symptom 2] The fan motor does not rotate when the unit is operating. (Diagnostic procedure) * Disconnect the motor connectors and measure the voltage at the DC motor connectors on the indoor unit controller (3 locations). Measurement location (1) Vm-Gnd: Between pin 1 and pin 3 (2) Vcc-Gnd: Between pin 4 and pin 3 (3) Vs-Gnd: Between pin 5 and pin 3 Normal value DC 230 V or more DC 14 V or more Fluctuation between DC 1.7 to 6.1 V (Diagnostic results) All of the above measured values are normal. Fan motor trouble (Replace the motor.) Any one of the above measured values is not normal. Indoor unit controller trouble (Replace the controller .) (Reference) DC motor connector pin arrangement Pin 1: Vm (red) Pin 2: Not used Pin 3: Gnd (black) Pin 4: Vcc (white) Pin 5: Vs (yellow) Pin 6: PG (blue) [Trouble symptom 3] Motor rotates for some time (several seconds), but then quickly stops, when the indoor unit operates. (There is trouble in the system that provides feedback of motor rotation speed from the motor to the indoor unit controller.) [Trouble symptom 4] Fan motor rotation speed does not change during indoor unit operation. [Trouble symptom 5] Fan motor rotation speed varies excessively during indoor unit operation. (Remedy for symptom 3 to 5) It is not possible to identify whether the trouble is indoor unit controller trouble or motor trouble. Therefore, first replace the indoor unit controller, then (if necessary) replace the DC motor. 41 8-5. Noise Malfunction and Electromagnetic Interference An inverter A/C operates using pulse signal control and high frequencies. Therefore, it is susceptible to the effects of external noise, and is likely to cause electromagnetic interference with nearby wireless devices. A noise filter is installed for ordinary use, preventing these problems. However, depending on the installation conditions, these effects may still occur. Please pay attention to the points listed below. (1) Noise malfunction This refers to the application of high-frequency noise to the signal wires, resulting in abnormal signal pulses and malfunction. Locations most susceptible to noise 1. Locations near broadcast stations where there are strong electromagnetic waves 2. Locations near amateur radio (short wave) stations 3. Locations near electronic sewing machines and arc-welding machines Trouble Either of the following trouble may occur. 1. The unit may stop suddenly during operation. 2. Indicator lamps may flicker. Correction (The fundamental concept is to make the system less susceptible to noise.) - Insulate for noise or distance from the noise source. 1. Use shielded wires. 2. Move unit away from the noise source. (2) Electromagnetic interference This refers to noise generated by high-speed switching of the microcomputer and compressor. This noise radiates through space and returns to the electric wiring, affecting any wireless devices (televisions, radios, etc.) located nearby. Locations most susceptible to noise 1. A television or radio is located near the A/C and A/C wiring. 2. The antenna cable for a television or radio is located close to the A/C and A/C wiring. 3. Locations where television and radio signals are weak. Trouble Correction 1. Noise appears in the television picture, 1. Select a separate power source. or the picture is distorted. 2. Keep the A/C and A/C wiring at least 1 meter 2. Static occurs in the radio sound. away from wireless devices and antenna cables. 3. Change the wireless deviceÕs antenna to a high-sensitivity antenna. 4. Change the antenna cable to a BS coaxial cable. 5. Use a noise filter (for the wireless device). 6. Use a signal booster. 42 APPENDIX A Operating Instructions CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU (852-6-4181-217-00-2) A-1 Operating Instructions Split System Air Conditioner Model No. Indoor Units Outdoor Units CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU This air conditioner uses the refrigerant R410A. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan 85264181217002 CV6233187617 FEATURES This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner. • Microprocessor Controlled Operation The interior compartment of the remote controller contains several features to facilitate automatic operation, easy logically displayed for easy use. • Simple One-touch Remote Controller The remote controller has several features to facilitate automatic operation. • 24-Hour ON or OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 24 hour period. • 1-Hour OFF Timer This timer can be set to automatically turn off the unit at any time after one hour. Automatic Restart Function for Power Failure Even when power failure occurs, preset programmed operation can be reactivated once power resumes. • High Power Operation If not in Auto Operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”. • Quiet Operation The fan rotates slower than the fan speed setting to provide a quieter operating sound. • • Night Setback This function saves energy by controlling operation to provide a quieter operating sound than normal. • Automatic and 3-step Fan Speed Auto/High/Medium/Low • Air Sweep Control This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner. • Auto. Flap Control This automatically sets the flap to the optimum position during heating, cooling, and drying operation. • Hot Start Heating System Right from the start, the air is warm and comfortable. This system prevents any cold blasts at the beginning while the heat pump is warming up, or even defrosting. CONTENTS Page Page FEATURES............................................................................. 2 PRODUCT INFORMATION .................................................... 2 SAFETY PRECAUTIONS....................................................... 2 INSTALLATION LOCATION.................................................... 3 ELECTRICAL REQUIREMENTS ........................................... 3 SAFETY INSTRUCTIONS...................................................... 3 NAMES OF PARTS ................................................................ 5 USING THE REMOTE CONTROLLER ................................ 10 OPERATION WITH THE REMOTE CONTROLLER............. 12 1. Automatic Operation ............................................. 12 2. Manual Operation.................................................. 13 3. Adjusting the Fan Speed ....................................... 14 4. Night Setback Mode.............................................. 15 5. QUIET Mode ......................................................... 16 6. HIGH POWER Mode............................................. 16 SPECIAL REMARKS ........................................................... 17 SETTING THE TIMER ......................................................... 18 USING THE 1-HOUR OFF TIMER....................................... 20 TIPS FOR ENERGY SAVING .............................................. 20 ADJUSTING THE AIRFLOW DIRECTION........................... 21 OPERATION WITHOUT THE REMOTE CONTROLLER..... 22 CARE AND CLEANING ....................................................... 22 WIRED REMOTE CONTROLLER........................................ 24 TROUBLESHOOTING (BEFORE CALLING FOR SERVICE)......25 OPERATING RANGE........................................................... 25 SPECIFICATIONS................................................................ 26 PRODUCT INFORMATION SAFETY PRECAUTIONS If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. Model No. __________________________________ Serial No. ___________________________________ Date of purchase _____________________________ Dealer’s address _____________________________ Phone number _______________________________ 2 CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. • • • Avoid: Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse. Do not install the air conditioner where excessively high heatgenerating objects are placed. To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. ELECTRICAL REQUIREMENTS 1. All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details. 2. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. 3. Wiring must be done by a qualified electrician. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. NOTE SAFETY INSTRUCTIONS • Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help. This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual. • • • • • • • • • Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. Never touch the unit with wet hands. Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous. Do not use this appliance in a potentially explosive atmosphere. This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case. Do not swallow the battery. After removing the battery from remote controller, keep it away from the reach of children. The battery can cause death by suffocation if swallowed. When inserting the battery, make sure the polarities (+ and -) are correct. 3 • • • • • • CAUTION • • • • • • • • NOTICE 4 To prevent possible hazards from insulation failure, the unit must be grounded. Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning. In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair. Refrigerant gas leakage may cause fire. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency. Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured. Keep the fire alarm and the air outlet at least 1.5m away from the unit. Do not let children play with the air conditioner. Do not cool or heat the room too much if babies or invalids are present. Do not sit or step on the unit. You may fall down accidentally. Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged. • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. • FCC Caution: To assure continued compliance, follow the attached installation instructions. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. NAMES OF PARTS Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose Refrigerant Tubes OUTDOOR UNIT Air Outlet NOTE This illustration is based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner which you have selected. This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote controller. Air Intake Air from the room is drawn into this section and passes through air filters which remove dust. Air Outlet Conditioned air is blown out of the air conditioner through the air outlet. Remote Controller The remote controller controls power ON/OFF, operation mode selection, temperature, fan speed, timer setting, and air sweeping. Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows. Drain Hose Outdoor (Condensing) Unit Moisture in the room condenses and drains off through this hose. The outdoor unit contains the compressor, fan motor, heat exchanger coil, and other electrical components. 5 UNIT DISPLAY AND OPERATION BUTTON INDOOR UNIT IMPORTANT Avoid using radio equipment such as mobile phone near (within 4 ft. (1.2m)) the remote control receiver. Some radio equipment may cause malfunction of the unit. QUIET OPERATION button If the trouble happens, disconnect power and restart the air conditioner after a few minutes. REMOTE CONTROL receiver OPERATION button OPERATION lamp TIMER lamp QUIET lamp REMOTE CONTROL receiver This section picks up infrared signals from the remote controller (transmitter). When the remote controller cannot be used, pressing this button enables heating and cooling operation. Each time this button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation. Cooling operation (green) OPERATION lamp Stop (lamp off) This lamp lights when the system is in the continuous AUTO (red or green), HEAT (red), DRY (orange) and COOL (green) mode. The OPERATION lamp lights up red and orange alternately when the system is defrosting. TIMER lamp This lamp lights when the system is being controlled by the timer. QUIET lamp This lamp lights during operation in the QUIET mode. NOTE 6 Heating operation (red) The unit’s display lamps are dimmed during operation in the NIGHT SETBACK mode. REMOTE CONTROLLER (DISPLAY) Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when setting timer Displayed when the time display is set to 12-hour time. Symbols (1) Operation mode AUTO ......................................... HEAT .......................................... MILD DRY .................................. COOL ......................................... (4) Timer 24-hour clock with ON/OFF program Timer............................ ON Timer.................................... OFF Timer. ................................. 1-hour OFF Timer....................... (2) Fan speed Automatic operation ................... HIGH ......................................... (5) NIGHT SETBACK ...................... (6) Confirmation of transmission...... MEDIUM..................................... (7) Auto. flap indication .................... LOW ........................................... Flap angle indication .................. (3) Temperature setting 60 – 86 °F When set to 80 °F temperature indication................ Sweep indication ........................ (8) High power operation ................. (9) Quiet operation........................... 7 REMOTE CONTROLLER Transmitter Sensor (Cover closed) Display QUIET button ON/OFF operation button 1 HR. TIMER button Temperature setting buttons (TEMP.) MODE selector button FAN SPEED selector button FLAP button ON TIME setting buttons Advance button Return button HIGH POWER button Advance button Return button OFF TIME setting buttons CANCEL button CLOCK button SENSOR button Time display selector button ACL button Temperature display selector button ADDRESS switch NOTE The illustration above pictures the remote controller after the cover has been opened. Transmitter When you press the buttons on the remote controller, the mark appears in the display to transmit the setting changes to the receiver in the air conditioner. Sensor A temperature sensor inside the remote controller senses the room temperature. Display Information on the operating conditions is displayed while the remote controller is switched on. If the unit is turned off, FLAP setting and FAN SPEED setting are not displayed. QUIET button ON/OFF operation button 1 HR. TIMER button (1-HOUR OFF TIMER) Temperature setting buttons (TEMP.) 8 NIGHT SETBACK button : When you press this button, the fan rotates slower than the fan speed setting to provide a quieter operating sound. This button is for turning the air conditioner on and off. : When you press this button, regardless of whether the unit is operating or stopping, the unit operates for one hour and then shuts down. Press the button to increase the set temperature. Press the button to reduce the set temperature. The temperature setting changes by 1 °C or 2 °F each time one of the TEMP. buttons is pressed. REMOTE CONTROLLER (CONTINUED) MODE selector button Use this button to select AUTO, HEAT, DRY or COOL mode. (AUTO) : The air conditioner calculates the difference between the thermostat setting and room temperature, and automatically selects ‘‘COOL’’ or ‘‘HEAT’’ mode as appropriate. (HEAT) : The air conditioner makes the room warmer. (DRY) (COOL) NOTE FAN SPEED selector button : The air conditioner reduces the humidity in the room. : The air conditioner makes the room cooler. When multiple indoor units are used and units in other rooms are already operating, they will be set to the same mode of operation as the operating indoor units. : The air conditioner automatically decides the fan speeds. : High fan speed : Medium fan speed : Low fan speed NIGHT SETBACK button For details, see “4. Night Setback Mode”. When you press this button in the HEAT, DRY or COOL mode, the mark appears in the display, and the remote controller will automatically adjust the set temperature to save energy. FLAP button Press this button either to select the setting of the airflow direction to the auto. flap in each mode or one of the six possible positions manually or to select the sweep function which moves the flap up and down automatically. : Auto flap setting: If selected in a heating operation, the flap is set to position (3) in the following chart. If selected in a cooling or dry operation, the flap is set at position (7) in the following chart. : The airflow direction can be set manually. (six positions) : The flap moves up and down automatically. NOTE When you press the FLAP button, the air flow direction will be changed one by one as follows. SWEEP HIGH POWER button ON TIME/OFF TIME setting buttons SENSOR button NOTE NOTE : If this button is pressed during HEAT, DRY or COOL operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”. No display: The timer does not operate. : The air conditioner starts at the set time. : The air conditioner stops at the set time. : The air conditioner stops and starts, or starts and stops, at the set times every day. For details, see “SETTING THE TIMER”. When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly. If the remote controller is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit. The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow. 9 REMOTE CONTROLLER (CONTINUED) Temperature Display Selector button This switches the temperature display between °C and °F. Time Display Selector button This switches the time display between 24-hour time and 12-hour time. ACL button (ALL CLEAR) ADDRESS switch Puts the remote controller into pre-operation status. Always press this button after replacing the batteries. • • NOTE The address switch changes to prevent mixing of signals from remote controller’s when two air conditioners are installed next to each other. Normally, the address switch is set to A. For more information, please contact the dealer where you made the purchase. Normally, the tabs on the remote controller should not be bent. The remote controller sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote controller stops for more than 15 minutes due to the loss of the remote controller or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote controller may differ from the temperature detected at the air conditioner’s position. USING THE REMOTE CONTROLLER How to Install Batteries 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. ACL button • CAUTION • • • • The batteries last about six months, depending on how much you use the remote controller. Replace the batteries when the remote controller’s display fails to light, or when the remote controller cannot be used to change the air conditioner’s settings. Use two fresh leak-proof type-AAA alkaline batteries. In replacing batteries, follow the instructions as mentioned in the subsection “How to Install Batteries”. If you do not use the remote controller more than 1 month, take out the batteries. Dispose of the used batteries at the designated location in compliance with the applicable local ordinances. Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. 10 Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Pb USING THE REMOTE CONTROLLER (CONTINUED) How to Use the Remote Controller When using the remote controller, always point the unit’s transmitter head directly at the air conditioner’s receiver. Air Conditioner (Indoor unit) Receiver (Transmitter head) Remote Controller Remote Controller Installation Position The remote controller may be operated either from a non-fixed position or from a wall-mounted position. To ensure that the air conditioner operates correctly, do not install the remote controller in the following places: • • • • • • • Mounting the Remote Controller In direct sunlight Behind a curtain or other places where it is covered More than 26 ft (8 m) away from the air conditioner In the path of the air conditioner’s airstream Where it may become extremely hot or cold Where it may be subject to electrical or magnetic noise Where there is an obstacle between the remote controller and air conditioner (since a check signal is sent from the remote controller every 5 minutes) Before mounting the remote controller, press the ON/OFF operation button at the mounting location to make sure that the air conditioner operates from that location. The indoor unit should make a beeping sound to indicate that it has received the signal. Remote Control Holder Rear Side Press Mounting Screws 5/32 x 5/8" (4 x 16 mm) (included) Set in place Hole • To prevent loss of the remote controller, you can connect the remote controller to the holder by passing a string through the remote controller and attachment hole. To take out the remote controller, pull it forward. When Holding the Remote Controller • • When using the remote controller and during air conditioner operation, the transmitter on the remote controller should be pointed towards the receiver on the indoor unit. Make sure that there are no objects between the remote controller and receiver which could block the signal. 11 OPERATION WITH THE REMOTE CONTROLLER 1. Automatic Operation The air conditioner calculates the difference between the thermostat setting and room temperature, and automatically determines the mode to operate under cooling or heating. Then, the air conditioner continuously operates under the mode selected at initial operation. STEP 2 STEP 1 NOTE Check that the circuit breaker on the power panel is turned on. Once mode is selected and the unit is preset by following the steps below, you can have the air conditioner automatically bring the room to the desired temperature simply by pressing the ON/OFF operation button. STEP 1 Press the MODE selector button to STEP 2 Press the ON/OFF operation button. . To stop the air conditioner, press the ON/OFF operation button again. NOTE 12 • To change the temperature setting; press the temperature setting buttons and change the setting to the desired temperature. OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 2. Manual Operation STEP 2 STEP 3 STEP 1 STEP 4 STEP 5 NOTE Check that the circuit breaker on the power panel is turned on. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. STEP 1 Press the MODE selector button and select the desired mode. For heating operation o For dehumidifying operation o For cooling operation o STEP 2 To start the air conditioner, press the ON/OFF operation button. STEP 3 Press the TEMP. setting buttons to change the temperature setting to the desired temperature. Adjustable temperature range: 30 °C max. 16 °C min. or 86 °F max. 60 °F min. STEP 4 Set the FAN SPEED selector button to the setting you want. STEP 5 Press the FLAP button and set the airflow direction as desired. (Refer to “ADJUSTING THE AIRFLOW DIRECTION” on page 21.) To stop the air conditioner, press the ON/OFF operation button again. NOTE When multiple indoor units are used and units in other rooms are already operating, they will be set to the same mode of operation as the operating indoor units. 13 OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) NOTE • Choose the best position in the room for the remote controller, which also acts as the sensor for room comfort and transmits the operating instructions. Once you’ve found this best position, always keep the remote controller there. • This appliance has a built-in 5-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. 3. Adjusting the Fan Speed 14 A. Automatic fan speed Simply set the FAN SPEED selector button to the position. This automatically sets the best fan speed for the room temperature. B. Manual fan speed If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired. [ , , or ] OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 4. Night Setback Mode Night Setback Mode is used for saving energy. Press the NIGHT SETBACK button while unit is operating. The mark appears in the display. To release the night setback function, press the NIGHT SETBACK button again. NOTE Pressing the MODE selector button cancels Night Setback mode. A. In Cooling and DRY Mode: ( and ) When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed. 2 °F Setting temperature Press the NIGHT SETBACK button B. In Heating Mode: ( ) 2 °F 30 min. Time 30 min. When the night setback mode is selected, the air conditioner automatically lowers the temperature setting 4 °F when 30 minutes have passed after the selection was made, and then another 4 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle heating is needed. Setting temperature 4 °F 4 °F Press the NIGHT SETBACK button 30 min. 30 min. Time 15 OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 5. QUIET Mode QUIET Mode is used to reduce the fan sound of the indoor unit. Press the QUIET button. The mark appears in the display. To cancel, press QUIET button again. • • In QUIET Mode, the fan rotates at a slower speed than the fan speed setting. If the unit is already operating with a very low airflow, the fan sound may not change even if the QUIET button is pressed. 6. HIGH POWER Mode HIGH POWER mode can be used to increase the output of the indoor unit for all operation modes except automatic operation. Press the HIGH POWER button while unit is operating. The mark appears in the display. To cancel, press HIGH POWER button again. • • • When the HIGH POWER button is pressed, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”. HIGH POWER Mode cannot be used when the operation mode is in Automatic Operation. QUIET Mode and HIGH POWER Mode cannot be used at the same time. NOTE 16 • Pressing the MODE selector button cancels HIGH POWER mode. • When set to High fan speed during heating operation, the fan runs at High fan speed even though the mark is displayed. • Depending on the operating conditions, the fan speed may be increased by a small amount only. SPECIAL REMARKS ‘‘DRY’’ ( ) Operation How it works? • • • Heating ( Once the room temperature reaches the level that was set, the unit’s operation frequency is changed automatically. During DRY operation, the fan speed automatically runs at lower speed for providing a comfortable breeze. ‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or less. ) Operation Heating performance • Because this air conditioner heats a room by drawing in the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance together with it. Defrosting • When the outdoor temperature is low, frost or ice may form on the heat exchanger coil, reducing heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan on the indoor unit stops and the OPERATION lamp lights red and orange alternately until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms.) Cold draft prevention • For several minutes after the start of heating operation, the indoor fan runs at a lower speed until the indoor heat exchanger coil has warmed up sufficiently. However, the fan may remain stopped when the room temperature is low. This is because the COLD DRAFT PREVENTION SYSTEM is in operating. • In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically within 15 minutes by the remote controller. • In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear. • The remote controller sends the setting condition to the air conditioner regularly at five minute intervals. Power failure during operation Clicking Sound Clicking sound is heard from the air conditioner Remote Controller 17 SETTING THE TIMER NOTE 1. How to set the present time In the descriptions below, the following settings are used for the temperature and time indicator selector button on the bottom front section of the remote controller. • Temperature: °F • Time: AM, PM (Example) To set to 10:30 pm. Operation 2. How to set the OFF time 1. Press the CLOCK button once if the time indicator is not flashing. The time indication alone flashes. 2. Press the Advance, Return ( , ) button until PM 10:30 is displayed. The time can be set in 1-minute increments. Holding down the button advances the time rapidly in 10-minute increments. 3. Press the CLOCK button again. This completes the setting of the current time. (Example) To stop the air conditioner at 11:00 am. Operation 18 Indication Indication 1. Press the OFF TIME setting button once. The timer indication is displayed, and the present OFF time is shown. 2. Press the Advance, Return ( , ) button until AM 11:00 is displayed. The timer indication blinks. The time can be set in 10-minute increments. Holding down the button advances the time rapidly in 10-minute increments. 3. Wait a few seconds, and then the setting is complete. The timer indication stops blinking and the present time is displayed. SETTING THE TIMER (CONTINUED) 3. How to set the ON time (Example) To start operation at 7:10 am. Operation 4. How to set DAILY ON/OFF REPEAT timer Indication 1. Press the ON TIME setting button once. The timer indication is displayed, and the present ON time is shown. 2. Press the Advance, Return ( , ) button until AM 7:10 is displayed. The timer indication blinks. The time can be set in 10-minute increments. Holding down the button advances the time rapidly in 10-minute increments. 3. Wait a few seconds, and then the setting is complete. The timer indication stops blinking and the present time is displayed. (Example) To start operation at 7:10 am. and stop the air conditioner at 11:00 am. 10:30 pm. Present time 7:10 am. ON Operation 1. Set the timer ON/OFF times as shown in 2-1, 2, 3 and 3-1, 2, 3. NOTE • • • To cancel a timer program NOTE 11:00 am. OFF Indication The present time 10:30 pm. and are displayed. The ON/OFF combination timer uses the current time as the reference, and it is activated starting from whichever set time comes first. With the ON/OFF combination timer, the settings are repeated every day. You can check the timer ON/OFF times after you have set them by pressing the ON TIME and OFF TIME setting buttons. • • Press the CANCEL button. When either an ON or OFF timer is to be canceled, press the button corresponding to the timer whose program is to be canceled, and then press the CANCEL button. • The airflow direction, fan speed and temperature setting can be changed after a timer program has been set even when the unit is stopped. Even when operation is stopped during an ON timer program, the unit will start operating when the set time is reached provided that the program is not canceled. When the ON timer and OFF timer are set to the same time, the timer operates as if it is turned off. • 19 USING THE 1-HOUR OFF TIMER 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The indicator in the display indicates that this function is operating. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button. appears in the display. Cancellation procedure: Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again. The 1-Hour Timer function is now cancelled and the unit operates normally. NOTE • • 2. Operation together with the DAILY ON/OFF REPEAT Timer If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops. It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later. The 1-Hour OFF Timer setting is given priority over the DAILY ON/OFF REPEAT setting. TIPS FOR ENERGY SAVING Avoid • • Do • • 20 Do not block neither the air intake nor the air outlet. It may cause less performance, and may leads to malfunctions. Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room. Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit. To prevent conditioned air from escaping, keep windows, doors and any other openings closed. ADJUSTING THE AIRFLOW DIRECTION 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down. CAUTION 2. Vertical The vertical airflow can be adjusted by moving the flap with the remote controller. Do not move the flap with your hands. Confirm that the remote controller has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings. SWEEP COOL DRY SWEEP HEAT A. Sweep function The flap starts moving up and down to deliver air over the sweep range. C. Auto flap function The flap is set to the recommended position. NOTE CAUTION B. Setting the airflow manually Referring to the above illustration, use the FLAP button to set the airflow direction within the range used during the heating, cooling, or dehumidifying operation. • • The flap automatically closes when the unit is off. During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position ) until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote controller. • Use the FLAP button on the remote controller to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote controller and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again. Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down. • 21 OPERATION WITHOUT THE REMOTE CONTROLLER INDOOR UNIT If you have lost the remote controller or it has trouble, follow the steps below. When the air conditioner is not running Each time the OPERATION button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation. Cooling operation (green) Heating operation (red) Stop (lamp off) OPERATION button NOTE The temperature is set to the room temperature minus 4 °F during the cooling operation and to the room temperature plus 4 °F during the heating operation, and the fan speed and flap are set to Auto. CARE AND CLEANING 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard. Casing and Grille (Indoor Unit) Clean the casing and grille of the indoor unit with a vacuum cleaner brush, or wipe them with a clean, soft cloth. If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the grille, be careful not to force the vanes out of place. CAUTION 22 1. Never use solvents, or harsh chemicals when cleaning the indoor unit. Do not wipe the plastic casing using very hot water. 2. Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts. 3. The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center. CARE AND CLEANING (CONTINUED) Filter How to remove the filter The filter behind the air intake grille should be checked and cleaned at least once every two weeks. 1. Grasp both ends of the air intake grille, and remove it by opening towards the front and pulling towards you. Air intake grille 2. Remove the filter attached to the rear of the air intake grille. Cleaning How to replace the filter filter Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it. 1. With the FRONT mark of the filter at the front, align the two indentions near the mark with the hooks at the rear of the air intake grille, and then mount the filter. filter FRONT mark Hook 2. Allow the edge of the air intake grille to slide into the top of the indoor unit, and then insert it all the way inside. 3. Press in the bottom right and left corners of the air intake grille to attach the indoor unit. NOTE Groove Air intake grille Pin Air intake grille Attach so that the round pins at the top right and left corners of the air intake grille are inserted into the grooves at the top right and left of the indoor unit. 23 CARE AND CLEANING (CONTINUED) Cleaning the main unit and Remote Controller • • • Removing and remounting the air intake grille CAUTION Washing the grille with water Wipe clean using a soft, dry cloth. To remove stubborn dirt, moisten a cloth in warm water no hotter than 104 °F, wring thoroughly, and then wipe. The air intake grille can be removed in order to wash it with water. Refer to “How to remove the filter” and “How to replace the filter” on page 23. When using a footstool or the like, be careful not to let it tip over. • • Clean the grille gently using a soft sponge, or the like. Then wipe away any remaining moisture. Neutral detergent may be used to remove stubborn dirt. Then rinse thoroughly with water and wipe away any remaining moisture. WIRED REMOTE CONTROLLER A separately sold wired remote controller (CZ-RD515U) used with this air conditioner is also available. If you wish to use the wired remote control function, you will need to purchase both the optional wired remote controller and its connection kit (CZ-RC515U). 24 TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center. Trouble Air conditioner does not run at all. Possible Cause Remedy 1. Power failure. 1. Restore power. 2. Leakage circuit breaker tripped. 2. Contact service center. 3. Line voltage is too low. 3. Consult your electrician or dealer. 4. Batteries in remote controller have run down. 4. Replace batteries. OPERATION lamp blinks and air conditioner does not operate. Trouble in system. Contact service center. Compressor runs but soon stops. Obstruction in front of condenser coil. (Outdoor Unit) Remove obstruction. Poor cooling (or heating) performance. 1. Dirty or clogged air filter. 1. Clean air filter to improve airflow. 2. Heat source or many people in room. 2. Eliminate heat source if possible. 3. Doors and/or windows are open. 3. Shut them to keep the heat (or cold) out. 4. Obstacle near air intake or air discharge port. 4. Remove it to ensure good airflow. 5. Thermostat is set too high for cooling (or too low for heating). 5. Set the temperature lower (or higher). 6. (Outdoor temperature is too low for heating.) 6. (Consult your dealer or try to use another heat appliance.) Clicking sound is heard from the air conditioner. In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear. OPERATION lamp lights but outdoor unit will not run. The use of cellular phones near the air conditioner may cause disturbance to its normal operation. 1. Turn off the power then restart the air conditioner after a while. 2. Consult your dealer. OPERATING RANGE The air conditioner is operable within the temperature ranges as listed below: COOLING HEATING Temperature Indoor air temperature Outdoor air temperature Max. 95 °F DB / 71 °F WB 115 °F DB Min. 67 °F DB / 57 °F WB 14 °F DB Max. 80 °F DB / 67 °F WB 75 °F DB / 65 °F WB Min. – DB / – WB – DB / 0 °F WB 25 SPECIFICATIONS Indoor Unit CS-MKE9NKU CS-MKE12NKU Power Source Single-phase, 208-230 V, 60 Hz 2.20 2.65 3.50 kW Cooling Capacity 7,500 9,000 11,900 BTU/h kW 2.50 3.60 4.20 Heating Capacity 8,500 12,200 14,300 BTU/h 33/30/27 34/31/28 36/33/29 Operation Cooling Operation (H/M/L) dB(A) Sound 33/30/27 34/31/28 34/31/29 Heating Operation (H/M/L) dB(A) Unit Dimensions (H×W×D) 11-7/32×32-15/32×7-7/16 11-7/32×32-15/32×7-7/16 11-7/32×32-15/32×7-7/16 inch(mm) (Indoor unit : Include panel) (285×825×189) (285×825×189) (285×825×189) lbs.(kg) Net Weight 19.8(9.0) 19.8(9.0) 19.8(9.0) Model No. Model No. Power Source Cooling Capacity Heating Capacity Operation Cooling Operation (Hi) Sound Heating Operation (Hi) Unit Dimensions (H×W×D) Net Weight 26 CS-MKE7NKU Outdoor Unit CU-4KE31NBU CU-4KE24NBU Single-phase, 208-230 V, 60 Hz 5.45 [ 2.90 ~ 5.45 ] 6.80 [ 2.90 ~ 6.80 ] 9.00 [ 2.90 ~ 9.00 ] kW 18,600 [ 9,800 ~ 18,600 ] 23,200 [ 9,800 ~ 23,200 ] 30,600 [ 9,800 ~ 30,600 ] BTU/h 7.30 [ 3.40 ~ 7.30 ] 8.60 [ 3.40 ~ 8.60 ] 9.40 [ 3.40 ~ 9.40 ] kW BTU/h 24,800 [ 11,600 ~ 24,800 ] 29,200 [ 11,600 ~ 29,200 ] 32,000 [ 11,600 ~ 32,000 ] dB(A) 50 50 53 dB(A) 52 52 52 29-1/8×35-7/16×12-19/32 29-1/8×35-7/16×12-19/32 35-1/32×35-7/16×12-19/32 inch(mm) (740×900×320) (740×900×320) (890×900×320) lbs.(kg) 143.3(65.0) 143.3(65.0) 180.8(82.0) CU-3KE19NBU APPENDIX B Operating Instructions CS-MKE18NKU CS-MKE24NKU (852-6-4181-218-00-2) A-2 Operating Instructions Split System Air Conditioner Model No. Indoor Units Outdoor Units CS-MKE18NKU CS-MKE24NKU CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU This air conditioner uses the refrigerant R410A. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 1006 Kadoma, Kadoma City, Osaka, Japan 85264181218002 CV6233187600 FEATURES This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner. • Microprocessor Controlled Operation The interior compartment of the remote controller contains several features to facilitate automatic operation, easy logically displayed for easy use. • Air Sweep Control This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner. • Simple One-touch Remote Controller The remote controller has several features to facilitate automatic operation. • Auto. Flap Control This automatically sets the flap to the optimum position during heating, cooling, and drying operation. • 24-Hour ON or OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 24 hour period. • • 1-Hour OFF Timer This timer can be set to automatically turn off the unit at any time after one hour. Hot Start Heating System Right from the start, the air is warm and comfortable. This system prevents any cold blasts at the beginning while the heat pump is warming up, or even defrosting. • Night Setback This function saves energy by controlling operation to provide a quieter operating sound than normal. Automatic Restart Function for Power Failure Even when power failure occurs, preset programmed operation can be reactivated once power resumes. • High Power Operation If not in Auto Operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”. • Quiet Operation The fan rotates slower than the fan speed setting to provide a quieter operating sound. • • Automatic and 3-step Fan Speed Auto/High/Medium/Low CONTENTS Page Page FEATURES................................................................................. 2 PRODUCT INFORMATION ........................................................ 2 SAFETY PRECAUTIONS........................................................... 2 INSTALLATION LOCATION........................................................ 3 ELECTRICAL REQUIREMENTS ............................................... 3 SAFETY INSTRUCTIONS.......................................................... 3 NAMES OF PARTS .................................................................... 5 USING THE REMOTE CONTROLLER .................................... 10 OPERATION WITH THE REMOTE CONTROLLER................. 12 1. Automatic Operation ................................................. 12 2. Manual Operation...................................................... 13 3. Adjusting the Fan Speed ........................................... 14 4. Night Setback Mode.................................................. 15 5. QUIET Mode ............................................................. 16 6. HIGH POWER Mode................................................. 16 SPECIAL REMARKS ................................................................17 SETTING THE TIMER ..............................................................18 USING THE 1-HOUR OFF TIMER ...........................................20 TIPS FOR ENERGY SAVING ...................................................20 ADJUSTING THE AIRFLOW DIRECTION ...............................21 OPERATION WITHOUT THE REMOTE CONTROLLER..........22 CARE AND CLEANING ............................................................22 WIRED REMOTE CONTROLLER ............................................24 TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) .......25 OPERATING RANGE................................................................25 SPECIFICATIONS.....................................................................26 PRODUCT INFORMATION SAFETY PRECAUTIONS If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. Model No. __________________________________ Serial No. ___________________________________ Date of purchase _____________________________ Dealer’s address _____________________________ Phone number _______________________________ 2 CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. • • • Avoid: Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse. Do not install the air conditioner where excessively high heatgenerating objects are placed. To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. ELECTRICAL REQUIREMENTS 1. All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details. 2. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. 3. Wiring must be done by a qualified electrician. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. NOTE SAFETY INSTRUCTIONS • Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help. This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual. • • • • • • • • • Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. Never touch the unit with wet hands. Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous. Do not use this appliance in a potentially explosive atmosphere. This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case. Do not swallow the battery. After removing the battery from remote controller, keep it away from the reach of children. The battery can cause death by suffocation if swallowed. When inserting the battery, make sure the polarities (+ and -) are correct. 3 • • • • • • CAUTION • • • • • • • • NOTICE 4 To prevent possible hazards from insulation failure, the unit must be grounded. Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning. In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair. Refrigerant gas leakage may cause fire. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency. Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured. Keep the fire alarm and the air outlet at least 1.5m away from the unit. Do not let children play with the air conditioner. Do not cool or heat the room too much if babies or invalids are present. Do not sit or step on the unit. You may fall down accidentally. Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged. • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. • FCC Caution: To assure continued compliance, follow the attached installation instructions. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. NAMES OF PARTS Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose Refrigerant Tubes OUTDOOR UNIT Air Outlet NOTE This illustration is based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner which you have selected. This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote controller. Air Intake Air from the room is drawn into this section and passes through air filters which remove dust. Air Outlet Conditioned air is blown out of the air conditioner through the air outlet. Remote Controller The remote controller controls power ON/OFF, operation mode selection, temperature, fan speed, timer setting, and air sweeping. Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows. Drain Hose Outdoor (Condensing) Unit Moisture in the room condenses and drains off through this hose. The outdoor unit contains the compressor, fan motor, heat exchanger coil, and other electrical components. 5 UNIT DISPLAY AND OPERATION BUTTON INDOOR UNIT IMPORTANT Avoid using radio equipment such as mobile phone near (within 4 ft. (1.2 m)) the remote control receiver. Some radio equipment may cause malfunction of the unit. QUIET OPERATION button If the trouble happens, disconnect power and restart the air conditioner after a few minutes. REMOTE CONTROL receiver OPERATION button OPERATION lamp TIMER lamp QUIET lamp REMOTE CONTROL receiver This section picks up infrared signals from the remote controller (transmitter). When the remote controller cannot be used, pressing this button enables heating and cooling operation. Each time this button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation. Cooling operation (green) OPERATION lamp Stop (lamp off) This lamp lights when the system is in the continuous AUTO (red or green), HEAT (red), DRY (orange) and COOL (green) mode. The OPERATION lamp lights up red and orange alternately when the system is defrosting. TIMER lamp This lamp lights when the system is being controlled by the timer. QUIET lamp This lamp lights during operation in the QUIET mode. NOTE 6 Heating operation (red) The unit’s display lamps are dimmed during operation in the NIGHT SETBACK mode. REMOTE CONTROLLER (DISPLAY) Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when setting timer Displayed when the time display is set to 12-hour time. Symbols (1) Operation mode AUTO ......................................... HEAT .......................................... MILD DRY .................................. COOL ......................................... (4) Timer 24-hour clock with ON/OFF program Timer ........................... ON Timer. .................................. OFF Timer. ................................ 1-hour OFF Timer. ..................... (2) Fan speed Automatic operation ................... HIGH ......................................... (5) NIGHT SETBACK...................... (6) Confirmation of transmission ..... MEDIUM..................................... (7) Auto. flap indication.................... LOW ........................................... Flap angle indication.................. (3) Temperature setting 60 – 86 °F When set to 80 °F temperature indication................ Sweep indication........................ (8) High power operation................. (9) Quiet operation .......................... 7 REMOTE CONTROLLER Sensor Transmitter (Cover closed) Display ON/OFF operation button QUIET button 1 HR. TIMER button Temperature setting buttons (TEMP.) MODE selector button FAN SPEED selector button NIGHT SETBACK button FLAP button ON TIME setting buttons HIGH POWER button Advance button Advance button Return button Return button OFF TIME setting buttons CANCEL button CLOCK button SENSOR button Time display selector button ACL button ADDRESS switch Temperature display selector button NOTE Transmitter When you press the buttons on the remote controller, the mark appears in the display to transmit the setting changes to the receiver in the air conditioner. Sensor A temperature sensor inside the remote controller senses the room temperature. Display Information on the operating conditions is displayed while the remote controller is switched on. If the unit is turned off, FLAP setting and FAN SPEED setting are not displayed. QUIET button ON/OFF operation button 1 HR. TIMER button (1-HOUR OFF TIMER) Temperature setting buttons (TEMP.) 8 The illustration above pictures the remote controller after the cover has been opened. : When you press this button, the fan rotates slower than the fan speed setting to provide a quieter operating sound. This button is for turning the air conditioner on and off. : When you press this button, regardless of whether the unit is operating or stopping, the unit operates for one hour and then shuts down. Press the button to increase the set temperature. Press the button to reduce the set temperature. The temperature setting changes by 1 °C or 2 °F each time one of the TEMP. buttons is pressed. REMOTE CONTROLLER (CONTINUED) MODE selector button Use this button to select AUTO, HEAT, DRY or COOL mode. (AUTO) : The air conditioner calculates the difference between the thermostat setting and room temperature, and automatically selects ‘‘COOL’’ or ‘‘HEAT’’ mode as appropriate. (HEAT) : The air conditioner makes the room warmer. (DRY) (COOL) NOTE FAN SPEED selector button : The air conditioner reduces the humidity in the room. : The air conditioner makes the room cooler. When multiple indoor units are used and units in other rooms are already operating, they will be set to the same mode of operation as the operating indoor units. : The air conditioner automatically decides the fan speeds. : High fan speed : Medium fan speed : Low fan speed NIGHT SETBACK button For details, see “4. Night Setback Mode”. When you press this button in the HEAT, DRY or COOL mode, the mark appears in the display, and the remote controller will automatically adjust the set temperature to save energy. FLAP button Press this button either to select the setting of the airflow direction to the auto. flap in each mode or one of the six possible positions manually or to select the sweep function which moves the flap up and down automatically. : Auto flap setting: If selected in a heating operation, the flap is set to position (3) in the following chart. If selected in a cooling or dry operation, the flap is set at position (7) in the following chart. : The airflow direction can be set manually. (six positions) : The flap moves up and down automatically. NOTE When you press the FLAP button, the air flow direction will be changed one by one as follows. SWEEP HIGH POWER button ON TIME/OFF TIME setting buttons SENSOR button NOTE NOTE : If this button is pressed during HEAT, DRY or COOL operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”. No display: The timer does not operate. : The air conditioner starts at the set time. : The air conditioner stops at the set time. : The air conditioner stops and starts, or starts and stops, at the set times every day. For details, see “SETTING THE TIMER”. When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly. If the remote controller is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit. The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow. 9 REMOTE CONTROLLER (CONTINUED) Temperature Display Selector button This switches the temperature display between °C and °F. Time Display Selector button This switches the time display between 24-hour time and 12-hour time. ACL button (ALL CLEAR) ADDRESS switch Puts the remote controller into pre-operation status. Always press this button after replacing the batteries. • • NOTE The address switch changes to prevent mixing of signals from remote controller’s when two air conditioners are installed next to each other. Normally, the address switch is set to A. For more information, please contact the dealer where you made the purchase. Normally, the tabs on the remote controller should not be bent. The remote controller sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote controller stops for more than 15 minutes due to the loss of the remote controller or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote controller may differ from the temperature detected at the air conditioner’s position. USING THE REMOTE CONTROLLER How to Install Batteries 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. ACL button CAUTION • • • • • 3. Use a thin object such as the tip of a pen to press the ACL button. The batteries last about six months, depending on how much you use the remote controller. Replace the batteries when the remote controller’s display fails to light, or when the remote controller cannot be used to change the air conditioner’s settings. Use two fresh leak-proof type-AAA alkaline batteries. In replacing batteries, follow the instructions as mentioned in the sub-section “How to Install Batteries”. If you do not use the remote controller more than 1 month, take out the batteries. Dispose of the used batteries at the designated location in compliance with the applicable local ordinances. Information for Users on Collection and Disposal of Old Equipment and used Batteries 10 [Information on Disposal in other Countries outside the European Union] Note for the battery symbol (bottom two symbol examples): These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. USING THE REMOTE CONTROLLER (CONTINUED) How to Use the Remote Controller When using the remote controller, always point the unit’s transmitter head directly at the air conditioner’s receiver. Air Conditioner (Indoor unit) Remote Controller Remote Controller Installation Position The remote controller may be operated either from a non-fixed position or from a wall-mounted position. To ensure that the air conditioner operates correctly, do not install the remote controller in the following places: • • • • • • • Mounting the Remote Controller Receiver (Transmitter head) In direct sunlight Behind a curtain or other places where it is covered More than 26 ft (8 m) away from the air conditioner In the path of the air conditioner’s airstream Where it may become extremely hot or cold Where it may be subject to electrical or magnetic noise Where there is an obstacle between the remote controller and air conditioner (since a check signal is sent from the remote controller every 5 minutes) Before mounting the remote controller, press the ON/OFF operation button at the mounting location to make sure that the air conditioner operates from that location. The indoor unit should make a beeping sound to indicate that it has received the signal. Rear Side Remote Control Holder Press Set in place Mounting Screws 5/32 x 5/8" (4 x 16 mm) (included) Hole • To prevent loss of the remote controller, you can connect the remote controller to the holder by passing a string through the remote controller and attachment hole. To take out the remote controller, pull it forward. When Holding the Remote Controller • • When using the remote controller and during air conditioner operation, the transmitter on the remote controller should be pointed towards the receiver on the indoor unit. Make sure that there are no objects between the remote controller and receiver which could block the signal. 11 OPERATION WITH THE REMOTE CONTROLLER 1. Automatic Operation The air conditioner calculates the difference between the thermostat setting and room temperature, and automatically determines the mode to operate under cooling or heating. Then, the air conditioner continuously operates under the mode selected at initial operation. STEP 2 STEP 1 NOTE Check that the circuit breaker on the power panel is turned on. Once mode is selected and the unit is preset by following the steps below, you can have the air conditioner automatically bring the room to the desired temperature simply by pressing the ON/OFF operation button. STEP 1 Press the MODE selector button to STEP 2 Press the ON/OFF operation button. . To stop the air conditioner, press the ON/OFF operation button again. NOTE 12 • To change the temperature setting; press the temperature setting buttons and change the setting to the desired temperature. OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 2. Manual Operation STEP 2 STEP 3 STEP 1 STEP 4 STEP 5 NOTE Check that the circuit breaker on the power panel is turned on. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. STEP 1 Press the MODE selector button and select the desired mode. For heating operation o For dehumidifying operation o For cooling operation o STEP 2 To start the air conditioner, press the ON/OFF operation button. STEP 3 Press the TEMP. setting buttons to change the temperature setting to the desired temperature. Adjustable temperature range: 30 °C max. 16 °C min. or 86 °F max. 60 °F min. STEP 4 Set the FAN SPEED selector button to the setting you want. STEP 5 Press the FLAP button and set the airflow direction as desired. (Refer to “ADJUSTING THE AIRFLOW DIRECTION” on page 21.) To stop the air conditioner, press the ON/OFF operation button again. NOTE When multiple indoor units are used and units in other rooms are already operating, they will be set to the same mode of operation as the operating indoor units. 13 OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) NOTE • Choose the best position in the room for the remote controller, which also acts as the sensor for room comfort and transmits the operating instructions. Once you’ve found this best position, always keep the remote controller there. • This appliance has a built-in 5-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. 3. Adjusting the Fan Speed 14 A. Automatic fan speed Simply set the FAN SPEED selector button to the position. This automatically sets the best fan speed for the room temperature. B. Manual fan speed If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired. [ , , or ] OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 4. Night Setback Mode Night Setback Mode is used for saving energy. Press the NIGHT SETBACK button while unit is operating. The mark appears in the display. To release the night setback function, press the NIGHT SETBACK button again. NOTE Pressing the MODE selector button cancels Night Setback mode. A. In Cooling and DRY Mode: ( and ) When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed. 2 °F Setting temperature Press the NIGHT SETBACK button B. In Heating Mode: ( ) 2 °F 30 min. Time 30 min. When the night setback mode is selected, the air conditioner automatically lowers the temperature setting 4 °F when 30 minutes have passed after the selection was made, and then another 4 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle heating is needed. Setting temperature 4 °F 4 °F Press the NIGHT SETBACK button 30 min. 30 min. Time 15 OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 5. QUIET Mode QUIET Mode is used to reduce the fan sound of the indoor unit. Press the QUIET button. The mark appears in the display. To cancel, press QUIET button again. • • In QUIET Mode, the fan rotates at a slower speed than the fan speed setting. If the unit is already operating with a very low airflow, the fan sound may not change even if the QUIET button is pressed. 6. HIGH POWER Mode HIGH POWER mode can be used to increase the output of the indoor unit for all operation modes except automatic operation. Press the HIGH POWER button while unit is operating. The mark appears in the display. To cancel, press HIGH POWER button again. • • • When the HIGH POWER button is pressed, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”. HIGH POWER Mode cannot be used when the operation mode is in Automatic Operation. QUIET Mode and HIGH POWER Mode cannot be used at the same time. NOTE 16 • Pressing the MODE selector button cancels HIGH POWER mode. • When set to High fan speed during heating operation, the fan runs at High fan speed even though the mark is displayed. • Depending on the operating conditions, the fan speed may be increased by a small amount only. SPECIAL REMARKS ‘‘DRY’’ ( ) Operation How it works? • • • Heating ( Once the room temperature reaches the level that was set, the unit’s operation frequency is changed automatically. During DRY operation, the fan speed automatically runs at lower speed for providing a comfortable breeze. ‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or less. ) Operation Heating performance • Because this air conditioner heats a room by drawing in the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance together with it. Defrosting • When the outdoor temperature is low, frost or ice may form on the heat exchanger coil, reducing heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan on the indoor unit stops and the OPERATION lamp lights red and orange alternately until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms.) Cold draft prevention • For several minutes after the start of heating operation, the indoor fan runs at a lower speed until the indoor heat exchanger coil has warmed up sufficiently. However, the fan may remain stopped when the room temperature is low. This is because the COLD DRAFT PREVENTION SYSTEM is in operating. • In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically within 15 minutes by the remote controller. • In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear. • The remote controller sends the setting condition to the air conditioner regularly at five minute intervals. Power failure during operation Clicking Sound Clicking sound is heard from the air conditioner Remote Controller 17 SETTING THE TIMER NOTE 1. How to set the present time In the descriptions below, the following settings are used for the temperature and time indicator selector button on the bottom front section of the remote controller. • Temperature: °F • Time: AM, PM (Example) To set to 10:30 pm. Operation 2. How to set the OFF time 1. Press the CLOCK button once if the time indicator is not flashing. The time indication alone flashes. 2. Press the Advance, Return ( , ) button until PM 10:30 is displayed. The time can be set in 1-minute increments. Holding down the button advances the time rapidly in 10-minute increments. 3. Press the CLOCK button again. This completes the setting of the current time. (Example) To stop the air conditioner at 11:00 am. Operation 18 Indication Indication 1. Press the OFF TIME setting button once. The timer indication is displayed, and the present OFF time is shown. 2. Press the Advance, Return ( , ) button until AM 11:00 is displayed. The timer indication blinks. The time can be set in 10-minute increments. Holding down the button advances the time rapidly in 10-minute increments. 3. Wait a few seconds, and then the setting is complete. The timer indication stops blinking and the present time is displayed. SETTING THE TIMER (CONTINUED) 3. How to set the ON time (Example) To start operation at 7:10 am. Operation 4. How to set DAILY ON/OFF REPEAT timer Indication 1. Press the ON TIME setting button once. The timer indication is displayed, and the present ON time is shown. 2. Press the Advance, Return ( , ) button until AM 7:10 is displayed. The timer indication blinks. The time can be set in 10-minute increments. Holding down the button advances the time rapidly in 10-minute increments. 3. Wait a few seconds, and then the setting is complete. The timer indication stops blinking and the present time is displayed. (Example) To start operation at 7:10 am. and stop the air conditioner at 11:00 am. 10:30 pm. Present time 7:10 am. ON Operation 1. Set the timer ON/OFF times as shown in 2-1, 2, 3 and 3-1, 2, 3. NOTE • • • To cancel a timer program NOTE 11:00 am. OFF Indication The present time 10:30 pm. and are displayed. The ON/OFF combination timer uses the current time as the reference, and it is activated starting from whichever set time comes first. With the ON/OFF combination timer, the settings are repeated every day. You can check the timer ON/OFF times after you have set them by pressing the ON TIME and OFF TIME setting buttons. • • Press the CANCEL button. When either an ON or OFF timer is to be canceled, press the button corresponding to the timer whose program is to be canceled, and then press the CANCEL button. • The airflow direction, fan speed and temperature setting can be changed after a timer program has been set even when the unit is stopped. Even when operation is stopped during an ON timer program, the unit will start operating when the set time is reached provided that the program is not canceled. When the ON timer and OFF timer are set to the same time, the timer operates as if it is turned off. • 19 USING THE 1-HOUR OFF TIMER 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The indicator in the display indicates that this function is operating. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button. appears in the display. Cancellation procedure: Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again. The 1-Hour Timer function is now cancelled and the unit operates normally. NOTE • • 2. Operation together with the DAILY ON/OFF REPEAT Timer If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops. It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later. The 1-Hour OFF Timer setting is given priority over the DAILY ON/OFF REPEAT setting. TIPS FOR ENERGY SAVING Avoid • • Do • • 20 Do not block neither the air intake nor the air outlet. It may cause less performance, and may leads to malfunctions. Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room. Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit. To prevent conditioned air from escaping, keep windows, doors and any other openings closed. ADJUSTING THE AIRFLOW DIRECTION 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down. CAUTION 2. Vertical The vertical airflow can be adjusted by moving the flap with the remote controller. Do not move the flap with your hands. Confirm that the remote controller has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings. SWEEP COOL DRY SWEEP HEAT A. Sweep function The flap starts moving up and down to deliver air over the sweep range. C. Auto flap function The flap is set to the recommended position. NOTE CAUTION B. Setting the airflow manually Referring to the above illustration, use the FLAP button to set the airflow direction within the range used during the heating, cooling, or dehumidifying operation. • • The flap automatically closes when the unit is off. During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position ) until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote controller. • Use the FLAP button on the remote controller to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote controller and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again. Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down. • 21 OPERATION WITHOUT THE REMOTE CONTROLLER INDOOR UNIT If you have lost the remote controller or it has trouble, follow the steps below. When the air conditioner is not running Each time the OPERATION button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation. Cooling operation (green) Heating operation (red) Stop (lamp off) OPERATION button NOTE The temperature is set to the room temperature minus 4 °F during the cooling operation and to the room temperature plus 4 °F during the heating operation, and the fan speed and flap are set to Auto. CARE AND CLEANING 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard. Casing and Grille (Indoor Unit) Clean the casing and grille of the indoor unit with a vacuum cleaner brush, or wipe them with a clean, soft cloth. If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the grille, be careful not to force the vanes out of place. CAUTION 22 1. Never use solvents, or harsh chemicals when cleaning the indoor unit. Do not wipe the plastic casing using very hot water. 2. Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts. 3. The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center. CARE AND CLEANING (CONTINUED) Filter How to remove the filter The filter behind the air intake grille should be checked and cleaned at least once every two weeks. 1. Grasp both ends of the air intake grille, and remove it by opening towards the front and pulling towards you. Air intake grille 2. Remove the filter attached to the rear of the air intake grille. Cleaning How to replace the filter Filter Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it. 1. With the FRONT mark of the filter at the front, align the two indentions near the mark with the hooks at the rear of the air intake grille, and then mount the filter. Filter FRONT mark Hook 2. Allow the edge of the air intake grille to slide into the top of the indoor unit, and then insert it all the way inside. 3. To attach the air intake grille to the indoor unit, press its bottom right and left corners as well as its bottom center into place. NOTE Groove Air intake grille Pin Air intake grille Attach so that the round pins at the top right and left corners of the air intake grille are inserted into the grooves at the top right and left of the indoor unit. 23 CARE AND CLEANING (CONTINUED) Cleaning the main unit and remote controller • • • Removing and remounting the air intake grille CAUTION Washing the grille with water Wipe clean using a soft, dry cloth. To remove stubborn dirt, moisten a cloth in warm water no hotter than 104 °F, wring thoroughly, and then wipe. The air intake grille can be removed in order to wash it with water. Refer to “How to remove the filter” and “How to replace the filter” on page 23. When using a footstool or the like, be careful not to let it tip over. • • Clean the grille gently using a soft sponge, or the like. Then wipe away any remaining moisture. Neutral detergent may be used to remove stubborn dirt. Then rinse thoroughly with water and wipe away any remaining moisture. WIRED REMOTE CONTROLLER A separately sold wired remote controller (CZ-RD515U) used with this air conditioner is also available. If you wish to use the wired remote control function, you will need to purchase both the optional wired remote controller and its connection kit (CZ-RC515U). 24 TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center. Trouble Possible Cause Air conditioner does not run at all. Remedy 1. Power failure. 1. Restore power. 2. Leakage circuit breaker tripped. 2. Contact service center. 3. Line voltage is too low. 3. Consult your electrician or dealer. 4. Batteries in remote controller have run down. 4. Replace batteries. OPERATION lamp blinks and air conditioner does not operate. Trouble in system. Contact service center. Compressor runs but soon stops. Obstruction in front of condenser coil. (Outdoor Unit) Remove obstruction. Poor cooling (or heating) performance. 1. Dirty or clogged air filter. 1. Clean air filter to improve airflow. 2. Heat source or many people in room. 2. Eliminate heat source if possible. 3. Doors and/or windows are open. 3. Shut them to keep the heat (or cold) out. 4. Obstacle near air intake or air discharge port. 4. Remove it to ensure good airflow. 5. Thermostat is set too high for cooling (or too low for heating). 5. Set the temperature lower (or higher). 6. (Outdoor temperature is too low for heating.) 6. (Consult your dealer or try to use another heat appliance.) Clicking sound is heard from the air conditioner. In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear. OPERATION lamp lights but outdoor unit will not run. The use of cellular phones near the air conditioner may cause disturbance to its normal operation. 1. Turn off the power then restart the air conditioner after a while. 2. Consult your dealer. OPERATING RANGE The air conditioner is operable within the temperature ranges as listed below: COOLING HEATING Temperature Indoor air temperature Outdoor air temperature Max. 95 °F DB / 71 °F WB 115 °F DB Min. 67 °F DB / 57 °F WB 14 °F DB Max. 80 °F DB / 67 °F WB 75 °F DB / 65 °F WB Min. – DB / – WB – DB / 0 °F WB 25 SPECIFICATIONS Indoor Unit Model No. CS-MKE18NKU Power Source Cooling Capacity Heating Capacity Cooling Operation Operation (H/M/L) Sound Heating Operation (H/M/L) Unit Dimensions (H×W×D) (Indoor unit : Include panel) Net Weight Single-phase, 208-230 V, 60 Hz kW 5.15 7.10 BTU/h 17,500 24,200 kW 6.00 8.50 BTU/h 20,400 29,000 dB(A) 41/38/34 44/41/38 dB(A) 40/37/34 43/40/37 inch (mm) 11-23/32×41-15/16×8-5/8 (298×1,065×219) 11-23/32×41-15/16×8-5/8 (298×1,065×219) lbs. (kg) 26.5 (12.0) 26.5 (12.0) Outdoor Unit Model No. CU-3KE19NBU Power Source Cooling Capacity Heating Capacity Cooling Operation Operation (Hi) Sound Heating Operation (Hi) Unit Dimensions (H×W×D) Net Weight 26 CS-MKE24NKU CU-4KE24NBU CU-4KE31NBU Single-phase, 208-230 V, 60 Hz kW 5.45 [2.90 ~ 5.45] 6.80 [2.90 ~ 6.80] 9.00 [2.90 ~ 9.00] BTU/h 18,600 [9,800 ~ 18,600] 23,200 [9,800 ~ 23,200] 30,600 [9,800 ~ 30,600] kW 7.30 [3.40 ~ 7.30] 8.60 [3.40 ~ 8.60] 9.40 [3.40 ~ 9.40] BTU/h 24,800 [11,600 ~ 24,800] 29,200 [11,600 ~ 29,200] 32,000 [11,600 ~ 32,000] dB(A) 50 50 53 dB(A) 52 52 52 inch (mm) 29-1/8×35-7/16×12-19/32 (740×900×320) 29-1/8×35-7/16×12-19/32 (740×900×320) 35-1/32×35-7/16×12-19/32 (890×900×320) lbs. (kg) 143.3 (65.0) 143.3 (65.0) 180.8 (82.0) APPENDIX C INSTALLATION INSTRUCTIONS CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU (852-6-4190-583-00-0) A-3 For Indoor Unit INSTALLATION INSTRUCTIONS Split System Air Conditioner Contents This air conditioner uses the refrigerant R410A. NOTE Page External diameter of service port R410A: 5/16" Model Combinations IMPORTANT! Please Read Before Starting .................................. 2 1. GENERAL .......................................................... 4 1-1. Tools Required for Installation (not supplied) 1-2. Accessories Supplied with Unit 1-3. Optional Copper Tubing Kit 1-4. Type of Copper Tube and Insulation Material 1-5. Additional Materials Required for Installation 2. INSTALLATION SITE SELECTION ................... 5 2-1. Indoor Unit 2-2. Embedding the Tubing and Wiring 3. HOW TO INSTALL THE INDOOR UNIT ............. 7 3-1. Remove the Rear Panel from the Unit 3-2. Make a Hole 3-3. Install the Rear Panel on the Wall 3-4. Removing and Installing the Grille 3-5. Shape the Indoor Side Tubing 3-6. Wiring Instructions 3-7. Wiring Instructions for Inter-unit Connections 3-8. Mounting 3-9. Drain Hose 4. HOW TO TEST RUN THE AIR CONDITIONER ... 17 5. REMOTE CONTROLLER INSTALLATION POSITION ......................................................... 18 5-1. Mounting on a Wall 6. ADDRESS SWITCH .......................................... 19 6-1. Address Setting of the Remote Controller 7. CONNECTING A HOME AUTOMATION DEVICE.............................................................. 20 8. INSTALLATION CHECK SHEET ...................... 20 Combine indoor and outdoor units only as listed below. Model No. Indoor Unit Outdoor Unit CS-MKE7NKU CU-3KE19NBU CS-MKE9NKU CU-4KE24NBU CS-MKE12NKU CU-4KE31NBU CS-MKE18NKU CS-MKE24NKU Power Source: 60 Hz, single-phase, 230 / 208 VAC 85264190583000 2011 CV6233187860 IMPORTANT! Please Read Before Starting When Transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers. This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. When Installing… Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. For safe installation and trouble-free operation, you must: Carefully read this instruction booklet before beginning. Follow each installation or repair step exactly as shown. Observe all local, state, and national electrical codes. Pay close attention to all warning and caution notices given in this manual. This symbol refers to a hazard or unsafe practice which can WARNING result in severe personal injury or death. This symbol refers to a hazard or unsafe practice which can CAUTION result in personal injury or product or property damage. …In a Ceiling or Wall Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support. …In a Room Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors. Keep the fire alarm and the air outlet at least 1.5 m away from CAUTION the unit. If Necessary, Get Help When Connecting Refrigerant Tubing These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions. In Case of Improper Installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. WARNING SPECIAL PRECAUTIONS WARNING :KHQSHUIRUPLQJpiping work do not mix air except for specified refrigerant (R410A) in refrigeration cycle. It causes capacity down, and risk of explosion and injury due to high tension inside the refrigerant cycle. 5HIULJHUDQWJDVOHDNDJHPD\ cause fire. When Wiring 'RQRWDGGRUUHSODFHUHIULJHUDQW other than specified type. It may cause product damage, burst and injury etc. ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM. 'RQRWVXSSO\SRZHUWRWKHXQLWXQWLODOOZLULQJDQGWXELQJ are completed or reconnected and checked. +LJKO\GDQJHURXVHOHFWULFDOYROWDJHVDUHXVHGLQWKLV system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death. *URXQGWKHXQLW following local electrical codes. &RQQHFWDOOZLULQJWLJKWO\/RRVHZLULQJPD\FDXVHRYHU heating at connection points and a possible fire hazard. 7RSUHYHQWSRVVLEOHKD]DUGVIURPLQVXODWLRQIDLOXUH the unit must be grounded. 9HQWLODWHWKHURRPZHOOLQWKHHYHQWWKDWUHIULJHUDQW gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas. 'RQRWDGGDQ\UHIULJHUDQWDLURUVXEVWDQFHLQWRWKH refrigeration circuit other than the designated refrigerant (R410A). Adding anything other than the specified refrigerant may cause the pressure to rise excessively in the refrigeration circuit, rupturing the circuit and causing injury or damage. 8VHDOOQHZWXELQJDQGIODUHQXWVWRPDNHWKHWXELQJFRQ nections. Using any previous parts (from R22-based systems) may result in damage to the equipment, and may lead to the refrigeration circuit rupturing, causing a serious accident. 2 $SSO\UHIULJHUDQWOXEULFDQWWRWKHPDWFKLQJVXUIDFHVRI the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection. &OHDQXSWKHVLWHDIWHU\RXILQLVKUHPHPEHULQJWRFKHFN that no metal scraps or bits of wiring have been left inside the unit being serviced. Others &KHFNFDUHIXOO\IRUOHDNVEHIRUHVWDUWLQJWKHWHVWUXQ 'RQRWOHDNUHIULJHUDQWZKLOHSLSLQJZRUNIRUDQLQVWDOODWLRQ or re-installation, and while repairing refrigeration parts. Handle liquid refrigerant carefully as it may cause frostbite. CAUTION 9HQWLODWHDQ\HQFORVHGDUHDVZKHQLQVWDOOLQJRUWHVWLQJ the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas. When Servicing 7XUQWKHSRZHU2)) DWWKHPDLQSRZHUER[PDLQV before opening the unit to check or repair electrical parts and wiring. &RQILUPXSRQFRPSOHWLQJLQVWDOODWLRQWKDWQRUHIULJHUDQW gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas. .HHS\RXUILQJHUVDQGFORWKLQJDZD\IURPDQ\PRYLQJ parts. NOTE The illustrations are based on the typical appearance of a standard model. Consequently, the shape may differ from that of the air conditioner that you are installing. 3 1. General 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning. 1-1. Tools Required for Installation (not supplied) 1. Standard screwdriver 2. Phillips head screwdriver 3. Knife or wire stripper 4. Tape measure 5. Carpenter’s level Sabre saw or key hole saw Hacksaw Core bits Hammer Drill Tube cutter Tube flaring tool Torque wrench Adjustable wrench Reamer (for deburring) 1-2. Accessories Supplied with Unit Table 1 Parts Figure Q’ty Parts Figure Remote controller 1 Tapping screw Remote control holder 1 Rawl plug AAA alkaline battery 2 Q’ty Truss-head Phillips 5/32 5/8" (4 16 mm) Parts Figure Q’ty 10 Clamp 1 8 Drain hose adapter 1 Packed in the indoor unit. 1-3. Optional Copper Tubing Kit 2. Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tubing, fittings and insulation. Consult your nearest sales outlet or air conditioning workshop. Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing. Wall thickness of the insulation should be not less than 5/16" (8 mm). 3. Use insulated copper wire for field wiring. Wire size varies with the total length of wiring. Refer to 3-6. Wiring Instructions for details. 1-4. Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source, you will need: 1. Deoxidized annealed copper tube for refrigerant tubing as detailed in Table 2. CAUTION Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to dampen vibration between units. Table 2 Narrow Tube Model Wide Tube Outer Dia. Thickness Outer Dia. Thickness CS-MKE7NKU 1/4" (6.35 mm) 0.0314" (0.8 mm) 3/8" (9.52 mm) 0.0314" (0.8 mm) CS-MKE9NKU 1/4" (6.35 mm) 0.0314" (0.8 mm) 3/8" (9.52 mm) 0.0314" (0.8 mm) CS-MKE12NKU 1/4" (6.35 mm) 0.0314" (0.8 mm) 3/8" (9.52 mm) 0.0314" (0.8 mm) CS-MKE18NKU 1/4" (6.35 mm) 0.0314" (0.8 mm) 1/2" (12.70 mm) 0.0314" (0.8 mm) CS-MKE24NKU 1/4" (6.35 mm) 0.0314" (0.8 mm) 5/8" (15.88 mm) 0.0393" (1.0 mm) 4 Check local electrical codes and regulations before obtaining wire. Also, check any specified instructions or limitations. 1-5. Additional Materials Required for Installation 1. 2. Refrigeration (armored) tape Insulated staples or clamps for connecting wire (See local codes.) Putty Refrigeration lubricant Clamps or saddles to secure refrigerant tubing 3. 4. 5. Indoor unit 2. Installation Site Selection 2-1. Indoor Unit WARNING To prevent abnormal heat generation and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surrounding the air conditioner in a way that may block air flow. Drain hose Outside drainage AVOID: direct sunlight. nearby heat sources that may affect performance of the unit. Fig. 1 areas where leakage of flammable gas may be expected. placing or allowing any obstructions near the air conditioner inlet or outlet. installing in rooms that contain instant-on (rapid-start) fluorescent lamps. (These may prevent the air conditioner from receiving signals.) places where large amounts of oil mist exist. installing in locations where there are devices that generate high-frequency emissions. 6" (15 cm) min. 2" (5 cm) min. Front View Fig. 2 INDOOR UNIT (1) Tubing length (L1) Elevation difference (H1) DO: select an appropriate position from which every corner of the room can be uniformly cooled. (High on a wall is best.) select a location that will hold the weight of the unit. select a location where tubing and drain hose have the shortest run to the outside. (Fig. 1) 2" (5 cm) min. INDOOR UNIT (2) L2 OUTDOOR UNIT H2 L3 H4 INDOOR UNIT (4) INDOOR UNIT (3) L4 H3 Fig. 3a CAUTION allow room for operation and maintenance as well as unrestricted air flow around the unit. (Fig. 2) Indoor unit For stable operation of the air conditioner, do not install wall-mounted type indoor units less than 5' (1.5 m) from floor level. install the unit within the maximum elevation difference (H1, H2, H3, H4) above or below the outdoor unit and ZLWKLQDWRWDOWXELQJOHQJWK/////// from the outdoor unit as detailed in Table 3 and Fig. 3a. Minimum height from floor level 5' (1.5 m) Floor level Fig. 3b 5 Wall install the indoor unit more than 3.3' (1 m) away from any antenna or power lines or connecting wires used for television, radio, telephone, security system, or intercom. Electrical noise from any of these sources may affect operation. install in a sturdy manner to avoid increased operating noise. Table 3 Model Max. Allowable Tubing Length Per Unit (ft.) Max. Allowable Total Tubing Length at Shipment (L1+L2+L3) or (L1+L2+L3+L4) (ft.) Limit of Total Tubing Length (L1+L2+L3) or (L1+L2+L3+L4) (ft.) Limit of Elevation Difference (H1, H2, H3, H4) (ft.) Required Amount of Additional Refrigerant (oz./ft.)* &8.(1%8 /// /// ³ &8.(1%8 //// //// &8.(1%8 //// //// * If total tubing length becomes 150 to 200 ft. (Max.) or 150 to 230 ft. (Max.), charge additional refrigerant (R410A) by 0.22 oz./ft. No additional charge of compressor oil is necessary. For more detailed charging information, refer to the Technical & Service Manual. 2-2. Embedding the Tubing and Wiring Before beginning embedding installation work, consult fully with agencies or offices related to the building’s foundation, construction, electricity, and water. Wait to make connections to the embedded portion. Each connection step is described later in this manual. Securely cover the end of the embedded tubing to prevent intrusion of dirt or moisture. If an embedded tube is to be left for a long time, fill the tube with nitrogen and seal both ends securely. If a tube is left open for an extended time, moisture in the air inside the tubing may condense into water droplets, and lead to water contamination of the refrigerant circuit. In order to prevent insulation breakdown and ground faults, do not allow wiring ends to come in contact with rainwater, or be subjected to condensation or dew. Apply sufficient thermal insulation to the refrigerant tubing and drain pipes. 6 3. How to Install the Indoor Unit 3-1. Remove the Rear Panel from the Unit (1) Remove and discard the set screw on the rear panel. (Fig. 6) (2) Press the 2 marks on the frame cover and disengage the stationary tabs from the frame. (Fig. 7) Set screw only for transportation (3) Remove the rear panel. Fig. 6 NOTE Tubing can be extended in 5 or 6 directions as shown in Fig. 8. Select the direction you need providing the shortest run to the outside unit. Rear panel When left tubing is to be done, switch the drain hose and drain cap. (For details, refer to “Switching drain hose and drain cap” on page 15.) 3-2. Make a Hole (1) Place the rear panel from the indoor unit on the wall at the location selected. Make sure the panel is horizontal, using a carpenter’s level or tape measure to measure down from the ceiling. Wait until after cutting the hole before attaching the rear panel to the wall. marks Fig. 7 Left tubing (2) Determine which side of the unit you should make the hole for tubing and wiring. (Fig. 9a or 9b) Right-rear tubing (recommended) Right tubing Left-downward Right-downward tubing tubing (Not applicable for CS-MKE18NKU, CS-MKE24NKU) NOTE In the case of left-rear tubing, use the measurement points from the edge of the rear panel for precise placement of the hose outlet. (Fig. 9a or 9b) Fig. 8 (CS-MKE7NKU, CS-MKE9NKU, CS-MKE12NKU) (3) Before making the hole, check carefully that no studs or pipes are directly run behind the spot to be cut. CAUTION Left-rear tubing 2-3/4" (70 mm) Also avoid areas where electrical wiring or conduits are located. The above precautions are also applicable if tubing goes through the wall in any other location. Fig. 9a 2-3/8" (60 mm) (CS-MKE18NKU, CS-MKE24NKU) Fig. 9b 7 (4) Using a sabre saw, key hole saw or hole-cutting drill attachment, cut a hole in the wall. See Table 4 and Fig. 10. NOTE Hole should be made at a slight downward slant to the outdoor side. Table 4 Indoor side Hole Dia. CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU 2-9/16" (65 mm) 3-5/32" (80 mm) (5) Measure the thickness of the wall from the inside edge to the outside edge and cut PVC pipe at a slight angle 1/4" (6 mm) shorter than the thickness of the wall. (Fig. 11) Outdoor side Fig. 10 39&SLSH/RFDOO\SXUFKDVHG (6) Place the plastic cover over the end of the pipe (for indoor side only) and insert the pipe in the wall. (Fig. 12) Cut at slight angle 3-3. Install the Rear Panel on the Wall Fig. 11 Be sure to confirm that the wall is strong enough to suspend the unit. INSIDE OUTSIDE Wall See either Item a) or b) below depending on the wall type. Plastic cover /RFDOO\SXUFKDVHG a) If Wooden Wall PVC pipe Slight angle (1) Attach the rear panel to the wall with the 8 screws provided. (Fig. 13a or 13b) Fig. 12 If you are not able to line up the holes in the rear panel with the beam locations marked on the wall, use rawl plugs or toggle bolts to go through the holes on the panel or drill 3/16" (5 mm) dia. holes in the panel over the stud locations and then mount the rear panel. (CS-MKE7NKU, CS-MKE9NKU, CS-MKE12NKU) (2) Double check with a carpenter’s level or tape measure that the panel is level. This is important to install the unit properly. (Fig. 14) Fig. 13a (3) Make sure the panel is flush against the wall. Any space between the wall and unit will cause noise and vibration. (CS-MKE18NKU, CS-MKE24NKU) b) If Block, Brick, Concrete or Similar Type Wall Make 3/16" (4.8 mm) dia. holes in the wall. Insert rawl plugs for appropriate mounting screws. (Fig. 15) Fig. 13b 3/16" (4.8 mm) dia. hole Rawl plug Fig. 14 Fig. 15 8 Grille Air intake grille 3-4. Removing and Installing the Grille 3-4-1. Indoor unit types (CS-MKE7NKU, CS-MKE9NKU, CS-MKE12NKU) Basically, these models can be installed and wired without removing the grille. If access to any internal part is needed, follow the steps as given below. CAUTION Fig. 16a Be sure to wear work gloves during installation to avoid being cut by the sharp aluminum fins of the heat exchanger. How to remove the grille (1) Grasp both ends of the air intake grille, and remove it by opening towards the front and pulling towards you. (Fig. 16a) (2) Remove the 2 screws. (Fig. 16b) Screw cover Fig. 16b Thermistor Cover (3) Remove the screw on the right side cover plate and open the cover. (Fig. 17a) (4) Take out the thermistor from the grille. (Fig. 17b) (5) Pull the lower part of the grille toward you to remove. (Fig. 18a) Thermistor Fig. 17b Fig. 17a (6) Use a standard screwdriver to push on the tabs to remove the grille. Tab * * How to replace the grille Frame (1) Reinstall the grille into the lower part while aligning its tabs on the upper part. (Fig. 18b) Insert the tabs in the slots and push the lower part of the grille back into position. Tab (2) Make sure that the grille and frame are firmly fitted together by engaging the tabs. Fig. 18a (3) Attach the thermistor on the grille. (Fig. 17a) * (4) Close the cover and replace the screw. (Fig. 17a) * (5) Affix the grille with the 2 previously removed screws. (Fig. 16b) (6) Install the air intake grille. (a) Allow the edge of the air intake grille to slide into the top of the indoor unit, and then insert it all the way inside. (Fig. 19a) Fig. 18b (b) Press the bottom right and left corners of the air intake grille to attach it to the indoor unit. (Fig. 19b) Groove NOTE Pin Attach so that the round pins at the top right and left corners of the air intake grille are inserted into the grooves at the top right and left of the indoor unit. Fig. 19b 9 Grille Fig. 19a 3-4-2. Indoor unit types (CS-MKE18NKU, CS-MKE24NKU) Grille Air intake grille Basically, these models can be installed and wired without removing the grille. If access to any internal part is needed, follow the steps as given below. How to remove the grille (1) Grasp both ends of the air intake grille, and remove it by opening towards the front and pulling towards you. (Fig. 16a-1) Fig. 16a-1 (2) Remove the 3 screws. (Fig. 16b-1) (3) Remove the screw on the right side cover plate and open the cover. (Fig. 17a-1) (4) Take out the thermistor from the grille. (Fig. 17b-1) (5) Press the 3 tabs at the top of the grille and the 3 tabs on the front face to separate the grille from the frame. (Fig. 18a-1) Thermistor Fig. 16b-1 Cover Thermistor (6) Pull the grill toward you to remove it. How to replace the grille Fig. 17a-1 (1) When installing the grille, place the bottom of the grille into the frame first. (Fig. 18b-1) Then insert the tabs on the top of the grille and on the front face into the frame. Fig. 17b-1 Tab (2) Make sure that the grille and frame are firmly fitted together by engaging the tabs. (3) Attach the thermistor on the grille. (Fig. 17a-1) (4) Close the cover and replace the screw. (Fig. 17a-1) Tab (5) Affix the grille with the 3 previously removed screws. (Fig. 16b-1) Fig. 18a-1 (6) Install the air intake grille. (a) Allow the edge of the air intake grille to slide into the top of the indoor unit, and then insert it all the way inside. (Fig. 19a-1) (b) Press the bottom right and left corners and center of the air intake grille to attach it to the indoor unit. (Fig. 19b-1) Fig. 18b-1 NOTE Groove Attach so that the round pins at the top right and left corners of the air intake grille are inserted into the grooves at the top right and left of the indoor unit. Pin Fig. 19b-1 Fig. 19a-1 10 3-5. Shape the Indoor Side Tubing (1) Arrangement of tubing by directions Frame a) Right or left tubing Cut out the corner of the right/left frame with a hacksaw or the like. (Figs. 20 and 21) Left tubing outlet b) Right-rear or left-rear tubing In this case, the corner of the frame need not be cut. (2) To mount the indoor unit on the rear panel: Fig. 20 Hang the 2 mounting slots of the unit on the upper tabs of the rear panel. (Fig. 22) Frame 3-6. Wiring Instructions General precautions on wiring (1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. Right tubing outlet (2) Provide a power outlet to be used exclusively for each unit, with a power supply disconnect and circuit breaker for overcurrent protection provided in the exclusive line. Fig. 21 (3) To prevent possible hazard due to insulation failure, the unit must be grounded. (4) Each wiring connection must be done tightly and in accordance with the wiring system diagram. Wrong wiring may cause the unit to misoperate or become damaged. Fig. 22 (5) Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan. (6) Unauthorized changes in the internal wiring can be very dangerous. The manufacturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes. 11 3-7. Wiring Instructions for Inter-unit Connections Rear panel (1) Insert the inter-unit wiring (according to local codes) into the through-the-wall PVC pipe. Run the wiring toward the indoor side allowing approx. 10" (25 cm) to extend from the wall face. (Fig. 24) Wall Plastic cover (2) Grasp both ends of the air intake grille, and remove it by opening towards the front and pulling towards you. Wiring 10" (25 cm) (3) Remove the screw on the right side cover plate and open the cover. (Fig. 25) Fig. 24 (4) Route the inter-unit wiring from the back of the indoor unit and pull it toward the front for connection. (Figs. 26a and 26b) Cover (5) Connect the inter-unit wiring to the corresponding terminals on the terminal plate (Figs. 26a and 26b) while referring to the wiring diagram. (6) Be sure to secure the wiring with the provided clamp. NOTE When closing the air intake grille, press the bottom right and left corners and center. (Fig. 27) Fig. 25 Please refer to “How to replace the grille” on page 9 or 10 for installing the air intake grille. Terminal plate Fig. 26a Fig. 27 Inter-unit wiring Earth plate /RFNQXW Top of conduit connector Fig. 26b 12 WARNING Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Therefore, be sure all wiring is tightly connected. When connecting each power wire to the corresponding terminal, follow the instructions “How to connect wiring to the terminal” and fasten the wire securely tight with the fixing screw of the terminal plate. 9/32" (7 mm) (ACTUAL SIZE) STRIP SIZE How to connect wiring to the terminal a) For Indoor Unit Fig. 28 Strip 15/16" (25 mm) (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the wire about 9/32" (7 mm). See the label (Fig. 28) near the terminal plate. (2) Using a screwdriver, loosen the terminal screw on the terminal plate. (3) Insert the wire and tighten the terminal screw completely using a screwdriver. Solid wire /RRS Insulation b) For Outdoor Unit Fig. 29 For solid core wiring (or F-cable) Strip 3/8" (10 mm) (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the solid wire about 15/16" (25 mm). (Fig. 29) (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. Stranded wire Ring connector (3) Using the pliers, bend the solid wire to form a loop suitable for the terminal screw. Fig. 30 (4) Shape the loop wire properly, place it on the terminal plate and fix it securely with the removed terminal screw using a screwdriver. Twist wire ends For stranded wiring (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about 3/8" (10 mm) and tightly twist the wire ends. (Figs. 30 and 31) Fig. 31 (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. Special washer (3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring connector. (Fig. 30) Screw Ring connector Wire (4) Place the ring connector wire, and replace and tighten the removed terminal screw using a screwdriver. (Fig. 32) Terminal plate Wire Fig. 32 13 Screw and special washer Ring connector 3-8. Mounting (1) To install the indoor unit, mount the indoor unit onto the 2 tabs on the upper part of the rear plate. (2) Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the lower part of the rear plate. (Fig. 33) Push NOTE For tubing, choose either the right or left tubing direction and follow the steps below. This work can be made easier by placing padding material (such as styrofoam) at the rear right side of the indoor unit. (Fig. 34) Fig. 33 Right-side tubing (1) Shape the refrigerant tubing so that it can easily go into the wall hole. (Fig. 35) (2) Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the rear panel. (Fig. 36) Padding material (3) Carefully bend the tubing (if necessary) to run along the wall in the direction of the outdoor unit and then tape as far as the fittings. (See Caution on page 19 in the outdoor unit installation manual.) The drain hose should come straight down the wall to a point where water runoff won’t stain the wall. Fig. 34 Rear panel Cover Refrigerant tubing (4) Connect the refrigerant tubing to the outdoor unit. (After performing a leak test on the connecting part, insulate it with the tubing insulation. (Fig. 37a)) Also, refer to Section 3-5. Tubing connections in the outdoor unit installation manual. Inter-unit wiring Drain hose (5) Assemble the refrigerant tubing, drain hose, and conduit (including inter-unit wiring) as shown in Fig. 37b. Fig. 35 Refrigerant tubing Insulation Fig. 37a Conduit Drain hose Inter-unit wiring Fig. 37b 14 Fig. 36 Left-side tubing Rear panel /HDGWKHWXELQJDQGGUDLQKRVHWKURXJKWKHZDOO allowing sufficient length for connection. Then bend the tubing using a tube bender to make the attachment. (Fig. 38) Hole in wall Bent part (2) Switch the drain hose and drain cap. Wide tube Narrow tube Fig. 38 Switching drain hose and drain cap D /RFDWHWKHGUDLQKRVHDQGWKHGUDLQFDS)LJ 39) (b) Remove the screw fastening the drain hose on the right side, and pull out the drain hose to remove it. (Fig. 39) Drain cap (c) Apply moderate force to pull off the drain cap on the left side. (If you cannot pull it off by hand, use a long-nose pliers.) Drain hose Fig. 39 (d) Reattach the drain hose to the left side and the drain cap to the right side. (Fig. 40a) Drain hose Slide the drain hose fully onto the drain pan outlet until the drain hose edge is pushed into the insulation. Check that the screw holes in the drain bracket and the drain pan outlet are aligned and securely in contact, then fasten them with the screw. (After attaching the drain hose, check that it is attached securely.) (Fig. 40c) Drain hose Clamp Drain cap Drain cap Use a Phillips screwdriver to push the drain cap in firmly. (If it is difficult to push in, wet the cap with water first.) Fig. 40a Screw hole (3) Install the indoor unit on the rear panel. (4) Connect the tubing and wiring led inside from outdoors. (5) After completing a leak test, bundle the tubing together with armoring tape and store it inside the tubing storage area at the back of the indoor unit and hold it with clamps. (Figs. 40a and 41) Drain pan outlet Insulation Drain bracket Drain bracket Drain hose Screw Drain hose Fig. 40c Fig. 40b Refrigerant tubing Inter-unit wiring Conduit Fig. 41 15 To unmount indoor unit Press the 2 marks on the lower part of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount. (Fig. 42) 3-9. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 43) b) Never form a trap in the course of the hose. c) If the drain hose will run in the room, insulate the hose with insulation* so that chilled condensation will not damage furniture or floors. (Fig. 44) Push * Foamed polyethylene or its equivalent is recommended. WARNING Fig. 42 Do not supply power to the unit or operate it until all tubing and wiring to the outside unit are completed. Slant Indoor unit Risk of Electric Shock Drain hose Fig. 43 Condensation Insulation material /RFDOO\SXUFKDVHG must be used. Fig. 44 16 4. How to Test Run the Air Conditioner After turning on the power of the air conditioner, use the remote controller and follow the steps below to conduct the test run. (1) Set the remote controller in Test Run mode. (Fig. 59a) a)Press and hold the QUIET button and the 1HR. TIMER button. E7KHQSUHVVDQGKROGWKH$&/ 5HVHWEXWWRQZLWKD pointed object such as the tip of a pen. After 5 secRQGVUHOHDVHWKH$&/ EXWWRQILUVW ON/OFF operation button QUIET button c) Then release the QUIET and 1HR. TIMER buttons. d) 1HR. TIMER button appears and “oP-1” blinking in the remote controller clock display area. (Fig. 59b) (2) Start Cooling mode test run by pressing the ON/OFF operation button of the remote controller. (Fig. 59a) 7KLVVWDUWVWKHIDQSURGXFLQJXQFRROHGIRUFHGDLUZLWK the 3 indicator lamps (OPERATION lamp, TIMER lamp and QUIET lamp) on the main unit blinking. (Fig. 59c) $IWHUPLQXWHVWKHV\VWHPVKLIWVLQWRFRROLQJRSHUD tion, and cool air will start to be felt. Cooling mode test run is unaffected by the room temperature. (3) Press the ON/OFF operation button of the remote controller again to stop the test run. (Fig. 59a) ACL (Reset) button Fig. 59a )LQDOO\SUHVVWKH$&/ 5HVHWEXWWRQRIWKHUHPRWHFRQ troller to release it from Test Run mode to return to normal mode. (Fig. 59a) ´ µDQG´R3µZLOOGLVDSSHDUIURPWKHUHPRWHFRQ troller clock display area. NOTE Troubleshooting: In the event that the green OPERATION lamp is blinking upon powering up the system, an error condition exists. In this case, refer to the self-diagnostics procedure on the inside of the front cover. Fig. 59b IMPORTANT After the test run is completed, be sure to press the $&/ 5HVHWEXWWRQWRUHWXUQWRQRUPDOPRGH7KH air conditioner will not operate correctly if this is not done. OPERATION lamp TIMER lamp QUIET lamp Fig. 59c 17 5. Remote Controller Installation Position The remote controller can be operated from either a non-fixed position or a wall-mounted position. To ensure that the air conditioner operates correctly, do not install the remote controller in the following places: In direct sunlight Behind a curtain or other place where it is covered More than 26' (8 m) away from the air conditioner In the path of the air conditioner’s airstream Where it may become extremely hot or cold Where it may be subject to electrical or magnetic interference Where there is an obstacle between the remote con- troller and the air conditioner (since a check signal is sent from the remote controller every 5 minutes) 5-1. Mounting on a Wall Before mounting the remote controller, press the ON/OFF operation button at the mounting location to make sure that the air conditioner operates from that location. The indoor unit should make a beeping sound to indicate that it has received the signal. Rear side Remote control holder Press Set in place Hole To prevent loss of the remote controller, you can connect the remote controller to the holder by passing a string through the remote controller and attachment hole. Mounting screws 5/32 x 5/8" (4 x 16 mm) (Included) To take out the remote controller, pull it forward. Fig. 61 18 6. Address Switch Tab 6-1. Address Setting of the Remote Controller The address can be set in order to prevent interference between remote controllers when 2 indoor units are installed near each other. The address is normally set to “A.” To set a different address, it is necessary to change the address on the second remote controller. Fig. 62 NOTE Once changed, you cannot restore the original address setting of the air conditioner. (1) Switch on the power source. (2) Break the address-setting tab marked “A” on the second remote controller to change the address (Fig. 62). When the tab is removed, the address is automatically set to B (Fig. 63). $&/EXWWRQ (3) Press and hold the remote controller QUIET button and 1HR. TIMER button. Then, press and hold the $&/ 5HVHWEXWWRQZLWKDSRLQWHGREMHFWVXFKDV WKHWLSRIDSHQ$IWHUVHFRQGVUHOHDVHWKH$&/ button first, then release the QUIET and 1HR. TIMER buttons. “oP-1” (Test Run) appears, blinking in the remote controller clock display area. Fig. 63 (4) Each time the 1HR. TIMER button is pressed, the display changes as shown below. Press this button 2 times to change the display to “oP-7” (Address setting). (Fig. 64) Test run mode ON/OFF operation button Selfdiagnostic mode QUIET button Address setting mode 1HR. TIMER button (5) “oP-7” has now been selected for address setting. (6) Press the ON/OFF operation button on the remote controller. (Fig. 64) Check that the “beep”signalreceived sound is heard from the second indoor unit (approximately 5 times). The sound you hear is the signal that the remote controller address has been changed. )LQDOO\SUHVVWKHUHPRWHFRQWUROOHU$&/ 5HVHWEXW ton to cancel the blinking “oP-7” display. (Fig. 64) Changing of the second remote controller address is now completed. ACL (Reset) button Fig. 64 19 7. Connecting a Home Automation Device The HA (white) 4P terminal is located on the indoor unit PCB. If a HA device will be used, connect it to this terminal. 8. Installation Check Sheet The strength of the installation location is sufficient to support the air conditioner weight. The indoor and outdoor units are installed level and vertically. The power and voltage are as specified. Inter-unit cables are securely inserted into the terminal block. Inter-unit cables are securely fixed. The power cable and inter-unit cables are not connected anywhere along their paths. The ground wire is securely connected. Thermal insulation has been applied to the tubing connections. Drain connections are secure and water drains properly. Putty has been used to close the hole in the wall. Remote controller signals are being positively received. 20 DC1111-0
advertisement