SeaLevel COMM+8 ISA 8-Port RS-232 Serial Interface User manual
Add to my manuals23 Pages
SeaLevel COMM+8 provides your PC with eight RS-232 asynchronous ports, allowing you to connect to any device using the RS-232 electrical interface, such as modems, data-entry terminals, and plotters. The COMM+8 occupies 64 I/O locations and can be addressed in two different ways: using a DIP-switch to set the base address for 64 consecutive I/O locations, or using the "PAL" option for customized addressing. Each port on the COMM+8 has an interrupt jumper that may need to be set prior to use, depending on the software you are using. The COMM+8 allows each port to have an independent interrupt level or share an interrupt with another port on the adapter, or even with a compatible port on another adapter.
advertisement
COMM+8™
USER MANUAL
Sealevel Systems, Inc.
PO Box 830
Liberty, SC 29657 USA
Part #3420
Telephone: (864) 843-4343
Fax: (864) 843-3067
www.sealevel.com
Contents
I
NTRODUCTION
........................................................................ 1
O
VERVIEW
......................................................................................1
W
HAT
’
S
I
NCLUDED
........................................................................1
F
ACTORY
D
EFAULT
S
ETTINGS
........................................................1
C
ARD
S
ETUP
............................................................................ 3
A
DDRESS
S
ELECTION
......................................................................3
“PAL” A
DDRESSING
......................................................................4
IRQ S
ELECTION
..............................................................................4
I
NTERRUPT
M
ODE
O
PTIONS
............................................................5
C
LOCK
M
ODES
...............................................................................6
B
AUD
R
ATES AND
D
IVISORS FOR THE
‘D
IV
1’
MODE
.......................7
I
NSTALLATION
......................................................................... 8
O
PERATING
S
YSTEM
I
NSTALLATION
...............................................8
For Windows Users ....................................................................8
Other Operating Systems ............................................................8
S
YSTEM
I
NSTALLATION
..................................................................8
T
ECHNICAL
D
ESCRIPTION
...................................................... 9
F
EATURES
.......................................................................................9
I
NTERRUPT
S
TATUS
P
ORT
...............................................................9
DB-25 C
ONNECTOR
P
IN
A
SSIGNMENTS
(DB-25 M
ALE
) ..............10
DB-9 (EIA-574 DTE) (DB-9 Male)..........................................10
DB-78 C
ONNECTOR
P
IN
A
SSIGNMENTS
(DB-78 F
EMALE
) ...........11
S
PECIFICATIONS
.................................................................... 12
E
NVIRONMENTAL
S
PECIFICATIONS
...............................................12
P
OWER
C
ONSUMPTION
.................................................................12
M
EAN
T
IME
B
ETWEEN
F
AILURES
(MTBF)...................................12
P
HYSICAL
D
IMENSIONS
................................................................12
A
PPENDIX
A - T
ROUBLESHOOTING
...................................... 13
A
PPENDIX
B - H
OW
T
O
G
ET
A
SSISTANCE
............................ 15
A
PPENDIX
C - E
LECTRICAL
I
NTERFACE
.............................. 16
RS-232 .........................................................................................16
A
PPENDIX
D - A
SYNCHRONOUS
C
OMMUNICATIONS
............ 17
A
PPENDIX
E - S
ILK
-S
CREEN
................................................. 18
A
PPENDIX
F - C
OMPLIANCE
N
OTICES
.................................. 19
F
EDERAL
C
OMMUNICATIONS
C
OMMISSION
S
TATEMENT
..............19
EMC D
IRECTIVE
S
TATEMENT
......................................................19
W
ARRANTY
............................................................................ 20
Figures
Figure 1 - Address Selection Table ...........................................................3
Figure 2 - DIP-switch Illustration.............................................................3
Figure 3 - Headers E1 to E8 (IRQ15 selected).........................................4
Figure 4 - Header E9 and E10, Normal IRQ Mode.................................5
Figure 5 - Header E9 and E10, Shared IRQ Mode .................................5
Figure 6 - Header E9 and E10, Sharing IRQs with another adapter ....6
Figure 7 - Clocking Mode ‘Divide By 4’...................................................6
Figure 8 - Clocking Mode ‘Divide By 1’...................................................7
Figure 9 - DB-25 Connector Pin Assignments .......................................10
Figure 10 - DB-25 Connector Pin Assignments .....................................10
Figure 11 - DB-78 Connector Pin Assignments .....................................11
Figure 12 - Asynchronous Communications Bit Diagram....................17
© Sealevel Systems, Inc.
SL9145 Revision 7/2006
Sealevel Systems, Incorporated. All rights reserved.
Introduction
Introduction
Overview
The Sealevel Systems COMM+8 provides the PC with eight RS-232 asynchronous ports. The COMM+8 allows for connection to any device utilizing the RS-232 electrical interface, such as modems, data-entry terminals, and plotters.
What’s Included
The COMM+8 is shipped with the following items. If any of these items is missing or damaged, contact the supplier.
• COMM+8 Serial I/O Adapter
• “Octopus” Cable providing 8 DB-25 or DB-9 connectors
• Sealevel Software
Factory Default Settings
The COMM+8 factory default settings are as follows:
Port #
Port 1
Base Address
280
288
290
298
2A0
2A8
IRQ
5
5
5
5
5
5
E12
DIV4
Port 2
Port 3
Port 4
Port 5
Port 6
Port 7
Port 8
2B0
2B8
5
5
To install the COMM+8 using factory default settings, refer to the Installation section of this manual.
Introduction
For your reference, record installed COMM+8 settings below:
Port # Base Address IRQ E12
The following table illustrates the port assignments for the Factory Default setting.
Port # DB-25# Address Example
Card Setup
The COMM+8 contains several jumper straps that must be set for proper operation.
Address Selection
The COMM+8 occupies 64 I/O locations and can be addressed two different ways. If header E11 is set to the “Switch” position the COMM+8 occupies 64 consecutive I/O locations and the DIP-switch is used to set the base address for these locations. The starting address for these 64 I/O locations must be on a 64-byte boundary i.e.: Hex 200, 240, 280, or 2C0.
Be careful when selecting the base address as some selections conflict with existing PC ports. The following table shows several examples that usually do not cause a conflict. Refer to Appendix A for common address contentions.
Address Switch Position Setting:
1 2 3 4 5 6 7
100-13F On On On On Off On On
180-1BF On On On On Off Off On
240-27F On On On Off On On Off
280-2BF On On On Off On Off On
2C0-2FF On On On Off On Off Off
300-3FF On On On Off Off On On
500-53F On On Off On Off On On
580-5BF On On Off On Off Off On
1500-153F Off On Off On Off On On
1580-15BF Off On Off On Off Off On
Figure 1 - Address Selection Table
The following illustration shows the correlation between the DIP-switch setting and the address bits used to determine the base address. In the example below, address 280 (Factory Default) is selected as a base.
ON
A12 A6
OFF
1 2 3 4 5 6 7
Figure 2 - DIP-switch Illustration
Note: Setting the switch “On” or “Closed” corresponds to a “0” in the address, while leaving it “Off” or “Open” corresponds to a “1”.
“PAL” Addressing
If header E11 is set to the “PAL” position, the board can be addressed at a customized location. Using the “PAL” option will allow you to obtain
COM1: - COM4: addresses, XENIX COM: addresses, or any other standard or nonstandard address configuration. Using the “PAL” feature is a very cost-effective means of solving complex addressing problems. For more information on implementing the “PAL” option, please contact
Sealevel Systems Technical Support.
IRQ Selection
Each port on the COMM+8 has an interrupt jumper that may have to be set prior to use. The software you are using with the board will determine which interrupts, if any are to be used. The DOS serial port interface software does not use interrupts, while interrupt buffer programs do. DOS does not require the interrupt to be set, while most Multi - User Operating
Systems will. Consult the particular manual for the software that you are using to determine the proper setting.
To set the interrupt for a particular port, first select the header for the port desired. Headers E1-E8 correspond to Ports 1-8. Next select an IRQ by placing one of the jumpers on the header location that corresponds to the
IRQ number that you wish to use. Below is an example of a selected IRQ.
2 3 4 5 6 7 10 11 12 15
Figure 3 - Headers E1 to E8 (IRQ15 selected)
Interrupt Mode Options
The COMM+8 will allow each port to have an independent interrupt level or share an interrupt with another port on the adapter. The COMM+8 will even share interrupts with a compatible port that is located on another adapter. The COMM+8 can operate in three interrupt modes. Header E9 determines the interrupt mode for Ports 1-4 and header E10 determines the interrupt mode for ports 5-8.
“N” indicates the (N)ormal, single interrupt per port mode. “S” Indicates the (S)hared interrupt mode, which allows more than one port to access a single IRQ. Any two or more ports can share a common IRQ by placing the jumpers on the same IRQ setting, and setting the appropriate selections at E1-E8. Consult your particular software for IRQ selection. If no interrupt is desired, remove the jumper. “M” indicates the inclusion of a
1K ohm pull-down resistor required on one port when sharing interrupts.
7
8
3
4
E10
N S M N S M
1
2
E9
5
6
Figure 4 - Header E9 and E10, Normal IRQ Mode
Set jumpers to “S” for shared interrupt mode on all blocks sharing an IRQ except one. Set that port block for “M”. This provides the pull-down resistor circuit that makes IRQ sharing possible. If you are using more than one COMM+8 or a compatible adapter in a bus you should only have one port set to “M”. The following example shows all eight ports sharing a single IRQ.
E10
7
8
5
6
N S M N S M
3
4
1
2
E9
Figure 5 - Header E9 and E10, Shared IRQ Mode
Set all jumpers to “S” if you are using more than one COMM+8 in a bus or you wish to completely remove the pull-down resistor for hardware compatibility. Setting the COMM+8 in this configuration when it is not
accompanied by a pull-down resistor will prevent the ports from
triggering an interrupt.
7
8
3
4
E10
N S M N S M
1
2
E9
5
6
Figure 6 - Header E9 and E10, Sharing IRQs with another adapter
Clock Modes
The COMM+8 employs a unique clocking option that allows the user to select from divide by 4 or divide by 1 clocking modes. This mode is selected at E12.
To select the Baud rates commonly associated with COM: ports (i.e. 2400,
4800, 9600, 19.2, … 115.2K Bps) place the jumper in the divide by 4 mode (silk-screen DIV4).
Figure 7 - Clocking Mode ‘Divide By 4’
To select the maximum data rate (460.8K bps) place the jumper in the divide by 1 (silk-screen DIV1) position.
Figure 8 - Clocking Mode ‘Divide By 1’
Baud Rates and Divisors for the ‘Div1’ mode
The following table shows some common data rates and the matching data rates you should choose if using the adapter in the ‘Div1’ mode.
For this Data Rate
1200 bps
2400 bps
4800 bps
9600 bps
19.2K bps
57.6 K bps
115.2 K bps
230.4K bps
460.8K bps
Choose this Data Rate
300 bps
600 bps
1200 bps
2400 bps
4800 bps
14.4K bps
28.8K bps
57.6 K bps
115.2 K bps
If your communications package allows the use of Baud rate divisors, choose the appropriate divisor from the following table:
For this Data Rate
1200 bps
2400 bps
4800 bps
9600 bps
19.2K bps
38.4K bps
57.6K bps
115.2K bps
230.4K bps
460.8K bps
Choose this Divisor
384
192
96
48
24
12
8
4
2
1
Installation
Installation
Operating System Installation
For Windows Users
Start by choosing Install Software at the beginning of the CD.
Choose Asynchronous COM: Port Software, SeaCOM.
Other Operating Systems
Refer to the appropriate section of the Serial Utilities Software.
System Installation
The COMM+8 can be installed in any 16-bit PC expansion slot. The
COMM+8 contains several jumper straps for each port that must be set for proper operation prior to installing the COMM+8 into the computer.
1. Turn off PC power. Disconnect the power cord.
2. Remove the PC case cover.
3. Locate an available slot and remove the blank metal slot cover.
4. Gently insert the COMM+8 into the slot. Make sure that the adapter is seated properly.
5. Replace the screw.
6. Install the “Octopus” Cable
7. Replace the cover.
8. Connect the power cord.
Installation is complete.
Technical Description
The Sealevel COMM+8 provides 8 additional serial ports for terminals, modems, printers, etc. The COMM+8 utilizes the 16554 UART chip. This chip features programmable baud rate, data format, interrupt control and a
16 byte FIFO.
Features
• Eight RS-232 Ports with full modem control signals
• “PAL” addressing option allowing “Turn Key” configurations
• Selectable/Sharable Interrupts (IRQs 2/9-7,10,11,12, & 15 )
• 8 DB-9 or DB-25 male connectors provided using the Sealevel
Systems “Octopus Cable”
Interrupt Status Port
The COMM+8 provides the user with an Interrupt Status Port (ISP) for greater throughput when servicing multiple ports on a single interrupt line.
The ISP is a read only 8-bit register that sets a corresponding bit when an interrupt is pending. Port 1 interrupt line corresponds with Bit D0 of the status port, Port 2 with D1 etc.
The ISP can be addressed two different ways. If header E11 is in the
“Switch” position the Status Register is located at Base+7 on each port
(Example: Base = 280 Hex, Status Port = 287, 28F… etc.). This allows any one of eight locations to be read to obtain the value in the status register.
All eight status ports on the COMM+8 are identical, so any one of the eight can be read. If header E11 is in the “PAL” position, the status port can be addressed at any location. Please contact Sealevel Systems for information on PAL programming and custom configurations.
Example: This indicates that Channel 2 has an interrupt pending.
Value 0
DB-25 Connector Pin Assignments (DB-25 Male)
GND Ground
RTS
DTR
Request To Send
Data Terminal Ready
CTS
DSR
DCD
Clear To Send
Data Set Ready
Data Carrier Detect
7
4
20
Output
Output
3 Input
5 Input
6 Input
8 Input
Figure 9 - DB-25 Connector Pin Assignments
DB-9 (EIA-574 DTE) (DB-9 Male)
Signal Name
GND Ground 5
TD Transmit Output
RTS
DTR
Request To Send
Data Terminal Ready
7
4
Output
Output
CTS Clear To Send 8 Input
DSR
DCD
Data Set Ready
Data Carrier Detect
6
1
Input
Input
RI Ring Input
Figure 10 - DB-9 Connector Pin Assignments
DB-78 Connector Pin Assignments (DB-78 Female)
Port 1 2 3 4 5 6 7 8
TD 36 12 27 3 75 51 66 42
RD
RTS
CTS
37 11 28 2 76 50 67 41
17 31 8 22 56 70 47 61
16 32 7 23 55 71 46 62
DTR 35 13 26 4 74 52 65 43
DSR 18 30 9 21 57 69 48 60
DCD 38 10 29 1 77 49 68 40
RI 15 33 6 24 54 72 45 63
GND 34 14 25 5 73 53 64 44
Figure 11 - DB-78 Connector Pin Assignments
Technical Note: Please terminate any control signals that are not going to be used. The most common way to do this is connect RTS to CTS and RI.
Also, connect DCD to DTR and DSR. Terminating these pins, if not used, will help insure you get the best performance from your adapter.
Specifications
Specifications
Environmental Specifications
Specification Operating Storage
Temperature
Range
0º to 50º C
(32º to 122º F )
-20º to 70º C
(-4º to 158º F)
Humidity Range
10 to 90% R.H.
Non-Condensing
10 to 90% R.H.
Non-Condensing
Power Consumption
Supply line
Rating
+12 VDC
110 mA
-12 VDC
130 mA
+5 VDC
320 mA
Mean Time Between Failures (MTBF)
Greater than 150,000 hours. (Calculated)
Physical Dimensions
Board length 7.0 inches
Board Height including Goldfingers 4.2 inches
Board Height excluding Goldfingers 3.9 inches
(17.78 cm)
(10.66 cm)
(9.91 cm)
Appendix A - Troubleshooting
Appendix A - Troubleshooting
Serial Utility test software is supplied with the Sealevel Systems adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support.
1. Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc.
The I/O addresses used by these adapters, as well as the IRQ (if any) should be identified.
2. Configure your Sealevel Systems adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address.
3. Make sure the Sealevel Systems adapter is using a unique IRQ The
IRQ is typically selected via an on-board header block. Refer to the section on Card Setup for help in choosing an I/O address and IRQ.
4. Make sure the Sealevel Systems adapter is securely installed in a motherboard slot.
5. When running DOS, Windows 3.x or other operating systems refer to the Serial Utilities software for that operating system and the User
Manual to verify that the Sealevel Systems adapter is configured correctly. The supplied software contains a diagnostic program 'SSD' that runs under DOS and will verify if an adapter is configured properly. This diagnostic program is written with the user in mind and is easy to use. Refer to the DIAG.txt file in the dos\diag directory for detailed instructions on using 'SSD'.
6. For Windows 95/98 and Windows NT, the diagnostic tool 'WinSSD' is installed in the Sealevel folder on the Start Menu during the setup process. First find the ports using the Device Manager, then use
'WinSSD' to verify that the ports are functional.
7. Always use the Sealevel Systems diagnostic software when troubleshooting a problem. This will help eliminate any software issues and identify any hardware conflicts.
8. The following are known I/O conflicts:
Appendix A - Troubleshooting
• The 278 and 378 settings may conflict with your printer I/O adapter.
• 3B0 cannot be used if a Monochrome adapter is installed.
• 3F8-3FF is typically reserved for COM1:
• 2F8-2FF is typically reserved for COM2:
• 3E8-3EF is typically reserved for COM3:
• 2E8-2EF is typically reserved for COM4:
Always use the Sealevel Systems diagnostic software when troubleshooting a problem. This will eliminate any software issues and help identify any hardware conflicts.
Appendix B – How To Get Assistance
Appendix B - How To Get Assistance
Please refer to Troubleshooting Guide prior to calling Technical Support.
1. Begin by reading through the Trouble Shooting Guide in
Appendix A. If assistance is still needed please see below.
2. When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
3. Sealevel Systems provides an FAQ section on its web site.
Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.htm
.
4. Sealevel Systems maintains a Home page on the Internet. Our home page address is www.sealevel.com
. The latest software updates, and newest manuals are available via our FTP site that can be accessed from our home page.
5. Technical support is available Monday to Friday from 8:00 a.m. to 5:00 p.m. eastern time. Technical support can be reached at (864) 843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM
SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE
WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED
BY CALLING SEALEVEL SYSTEMS AND REQUESTING A
RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Appendix C - Electrical Interface
Appendix C - Electrical Interface
RS-232
Quite possibly the most widely used communication standard is RS-232.
This implementation has been defined and revised several times and is often referred to as RS-232-C/D/E or EIA/TIA-232-C/D/E. It is defined as
“Interface between Data Terminal Equipment and Data Circuit-
Terminating Equipment Employing Serial Binary Data Interchange” The mechanical implementation of RS-232 is on a 25 pin D sub connector. The
IBM PC computer defined the RS-232 port on a 9 pin D sub connector and subsequently the EIA/TIA approved this implementation as the
EIA/TIA-574 standard. This standard has defined as the “9-Position Non-
Synchronous Interface between Data Terminal Equipment and Data
Circuit-Terminating Equipment Employing Serial Binary Data
Interchange”. Both implementations are in wide spread use and will be referred to as RS-232 in this document. RS-232 is capable of operating at data rates up to 20 Kbps / 50 ft. The absolute maximum data rate may vary due to line conditions and cable lengths. RS-232 often operates at 38.4
Kbps over very short distances. The voltage levels defined by RS-232 range from -12 to +12 volts. RS-232 is a single ended or unbalanced interface, meaning that a single electrical signal is compared to a common signal (ground) to determine binary logic states. A voltage of +12 volts
(usually +3 to +10 volts) represents a binary 0 (space) and -12 volts
(-3 to -10 volts) denotes a binary 1 (mark). The RS-232 and the EIA/TIA-
574 specification define two types of interface circuits Data Terminal
Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The
Sealevel Systems Adapter is a DTE interface.
Appendix D - Asynchronous Communications
Appendix D - Asynchronous Communications
Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing
(start/stop bits) are pre-defined and must correspond at both the transmitting and receiving ends.
Asynchronous communications is the standard means of serial data communication for PC compatibles and PS/2 computers. The original PC was equipped with a communication or COM: port that was designed around an 8250 Universal Asynchronous Receiver Transmitter (UART).
This device allows asynchronous serial data to be transferred through a simple and straightforward programming interface. Character boundaries for asynchronous communications are defined by a starting bit followed by a pre-defined number of data bits (5, 6, 7, or 8). The end of the character is defined by the transmission of a pre-defined number of stop bits (usually 1,
1.5 or 2). An extra bit used for error detection is often appended before the stop bits.
1
Idle state of
line
5 to 8 Data Bits
Odd, Even
or
Unused
Remain Idle or next start bit
P
BIT
STOP
0
1
1.5
2
Figure 12 - Asynchronous Communications Bit Diagram
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission.
There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd
Parity. Sometimes parity is not used to detect errors on the data stream.
This is referred to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped
(framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications have to be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits
(i.e. 9600,N,8,1).
Appendix E - Silk-Screen
Appendix E - Silk-Screen
3.9"
7.0"
4.2"
Appendix F - Compliance Notices
Appendix F - Compliance Notices
Federal Communications Commission Statement
FCC - This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference.
In such case the user will be required to correct the interference at his own expense.
EMC Directive Statement
•
Products bearing the CE Label fulfill the requirements of the EMC directive (89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European
Commission.
To obey these directives, the following European standards must be met:
• EN55022 Class A - “Limits and methods of measurement of radio interference characteristics of information technology
equipment”
• EN55024-‘Information technology equipment Immunity characteristics Limits and methods of measurement.
EN60950 (IEC950) - “Safety of information technology equipment, including electrical business equipment”
Warning
This is a Class A Product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives.
Warranty
Warranty
Sealevel Systems, Inc. provides a limited lifetime warranty. Should this product fail to be in good working order at any time during this period,
Sealevel Systems will, at it’s option, replace or repair it at no additional charge except as set forth in the following terms. This warranty does not apply to products damaged by misuse, modifications, accident or disaster.
Sealevel Systems assumes no liability for any damages, lost profits, lost savings or any other incidental or consequential damage resulting from the use, misuse of, or inability to use this product. Sealevel Systems will not be liable for any claim made by any other related party.
RETURN AUTHORIZATION MUST BE OBTAINED FROM
SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE
WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED
BY CALLING SEALEVEL SYSTEMS AND REQUESTING A
RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Sealevel Systems, Incorporated
2779 Greenville Highway
P.O. Box 830
Liberty, SC 29657 USA
(864) 843-4343 FAX:(864) 843-3067 www.sealevel.com
email: [email protected]
Technical Support is available from 8 a.m. to 5 p.m. Eastern time.