DOAL Config Guide

DOAL Config Guide
Nerlite
DOAL Series Illuminators
Configuration Guide
Continuous Current Strobe Current
Continuous
Operation
No
Controller
Required
(Can be
Connected
Part
Number
Description
Lighting
Fan
NER-011201305
DOAL-25 Red Continuous NER-011201314
DOAL-25 Red Strobe NER-011201313
DOAL-25 White Continuous NER-011200814
DOAL-50 V2 Red Continuous NER-011200812
DOAL-50 V2 Red Strobe NER-011200824
DOAL-50 V2 White Continuous NER-011200822
DOAL-50 V2 White Strobe NER-011200834
DOAL-50 V2 Blue Continuous NER-011200832
DOAL-50 V2 Blue Strobe NER-011200892
DOAL-50 V2 Infrared Continuous NER-011200897
DOAL-50 V2 Infrared Strobe NER-011200502
DOAL-75 Red Continuous NER-011200501
DOAL-75 Red Strobe NER-011204902
DOAL-75 White Continuous NER-011204901
DOAL-75 White Strobe NER-011205720
DOAL-75 Blue Continuous NER-011205721
DOAL-75 Blue Strobe NER-011200506
DOAL-75 Infrared Continuous NER-011200507
DOAL-75 Infrared Strobe NER-011200602
DOAL-100 Red Continuous NER-011200601
DOAL-100 Red Strobe NER-011204601
DOAL-100 White Continuous NER-011204600
DOAL-100 White Strobe NER-011204610
DOAL-100 Blue Continuous NER-011204611
DOAL-100 Blue Strobe NER-011200603
DOAL-100 Infrared Continuous NER-011200605
DOAL-100 Infrared Strobe 40mA
Lighting
Channel 1
Lighting
Channel 2
Fan
Cooled
Controller
Required
NL-2XX
(Select Any
LC100-350 LC100-700 LC100-1050 Optional
One of the
(Legacy)
(Legacy)
(Legacy) (Used only if
Indicated
(LC100 Used(LC100 Used (LC100 Used Intensity
LCXXX
Only if
Only If
Only If
And/Or
(Legacy) or
Intensity
Intensity
Intensity
Ethernet
Directly to NL2XX Series LC50-350
24VDC) Controllers (Legacy)
LC50-700
(Legacy)
LC50-1050 LC50-1400 LC50-2100
(Legacy)
(Legacy)
(Legacy)
Control is
Desired)
Control is
Desired)
Control is
Desired)
NL-2XX
Required)
NA
NA
NA
0.80A pk.
64mA
NA
NA
NA
Figure A
Figure B
200mA
NA
NA
NA
Figure A
Figure B
NA
NA
4.00A pk.
200mA
NA
NA
NA
NA
4.00A pk.
NA
NA
NA
NA
4.00A pk.
100mA
NA
NA
NA
NA
2.10A pk.
240mA
62mA
NA
4.80A pk.
NA
NA
480mA
62mA
NA
NA
NA
9.41A pk.
480mA
62mA
NA
NA
NA
9.41A pk.
240mA
62mA
NA
NA
NA
5.04A pk.
427mA
62mA
NA
NA
NA
8.40A pk.
823mA
62mA
NA
NA
NA
8.62A pk.
823mA
62mA
NA
NA
NA
8.62A pk.
418mA
62mA
NA
NA
NA
8.82A pk.
Figure A
Control Is
Desired)
NA
200mA
NA
Strobe
Operation
NA
Figure A
Figure A
NA
Figure A
Figure A
X
Figure A
X
Figure A
X
Figure A
X
Figure A
X
Figure A
X
Figure A
X
Figure A
Figure B
Figure B
Figure C
7.84A pk.
NA
Figure B
Figure C
7.84A pk.
NA
Figure B
Figure C
NA
NA
Figure B
Figure C
NA
NA
Figure B
Figure C
NA
NA
Figure B
Figure C
NA
NA
Figure B
Figure C
NA
NA
Figure B
Figure B
NA
X
Figure B
Figure B
NA
NA
Figure B
Figure B
NA
NA
back of
page)
Figure B
NA
NA
Connection
Notes
Reference
Number
(See the
Connection
Notes on
Figure B
Figure C
NA
Figure B
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
2
1
2
1
2
1
2
3
2
3
2
1
Hardware Required
1
2
Item
1
2
3
Description
DOAL Series Illuminators
Power Supply DSP60 24VDC 2.5A DIN Mount
NL-200 Series Lighting Controller
Part Number
NER-01120XXXX
NER-011504100
98-000152-0X
Figure A
DOAL Series Illuminator
with power supply
3
2
1
- POWER
+ INPUT
1
- 12V. 1.4A (UNFUSED)
+ POWER OUTPUT
- POWER
+ INPUT
- 12V. 1.4A (UNFUSED)
+ POWER OUTPUT
2
3
Fan Leads
Figure B
DOAL Series Illuminator
with NL-200 Controller and power supply
Copyright ©2010 Microscan Systems, Inc.
Figure C
DOAL Series Illuminator
with NL-200 Controller, power supply
And fan circuit
Lighting Leads
P/N 83-230004 Rev A
NERLITE DOAL Series Illuminators
Accessories
AC Power Cord US
AC Power Cord EU
AC Power Cord UK
NER-030028300
NER-030028400
NER-030028500
Power Cord For Power Supply
Power Cord For Power Supply
Power Cord For Power Supply
General Notes:
1. Those lights that do not require a controller require 24VDC +/- 1%.
2. The LC50 and LC100 series controllers require 24 to 40VDC.
3. The NL-2XX series controllers require 24 to 48VDC.
4. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions.
5. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions.
6. All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating.
7. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’
manual for pulse width and duty cycle limitations under various conditions.
8 ATTENTION! When programing an NL-2XX series controller for use in strobe mode, you must set the current rating to 10% of the current printed on the configuration label
on the light. The NL-2XX Series Controller allows the operator to set the output to 1000% of the rated current in strobe mode. By programming the initial current rating at
10% of the light’s rated current, full intensity is achieved and the controller is prevented from exceeding the light’s rated current. Setting the current rating at a value greater
than 10% of the current printed on the configuration label on the light may result in damage to the light.
Connection Notes:
1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the
power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground.
2. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the
power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground.
3. Connect the two leads labeled “V+1” & “V+2” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “GND1” & “GND2” to
the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground.
4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power
supply or controller. Connect the cable’s braided shield to chassis ground.
5. Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series
controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the
positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead
labeled “Shield” to chassis ground.
6. Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled
“RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground.
7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output
terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used.
Copyright ©2010 Microscan Systems, Inc.
www.microscan.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising