- No category
advertisement
Wasp WLP 4170 CCD
Programming Guide
Please Read
Note:
The Wasp WLP 4170 CCD Scanner is ready to scan the most popular bar codes out of the box. This manual
should only be used to make changes in the configuration of the scanner for specific applications.
This scanner does not require software or drivers to operate. The scanner enters data as keyboard data. Please review this manual before scanning any of the programming bar codes in this manual.
Tech Tip
If you are unsure of the scanner configuration or have scanned the incorrect codes, please scan the default bar code on page 6. This will reset the scanner to its factory settings.
Downloaded from www.Manualslib.com
manuals search engine
© Copyright Wasp Technologies 2002.
All rights reser ved.
Version 1.0
No part of this publication may be reproduced or transmitted in any form or by any means without the written permission of Wasp Technologies.
The information contained in this document is subject to change without notice.
Wasp is a trademark of Wasp Technologies. All other trademarks or registered trademarks are the property of their respective owners .
Downloaded from www.Manualslib.com
manuals search engine
Table of Contents
Chapter 1.
Chapter 2.
Chapter 3.
Chapter 4.
Chapter 5.
Appendix A.
Introduction..............................................................................1
Installation................................................................................2
Quick Start ..............................................................................3
Bar Code Symbologies............................................................4
Setup & Configuration........................................................5-34
1. Factory Default ..........................................................6
2. Beep and Delay..........................................................7
3. Intercharacter Delay ..................................................8
4. Keyboard Wedge........................................................9
5. Scanning Modes ......................................................10
6. Preamble/Postamble Configuration..........................11
5. Bar Code Symbology..........................................12-29
Code 39......................................................12-13
Code 128....................................................14-15
UPC-A ........................................................16-17
UPC-E ........................................................18-19
EAN-13 ......................................................20-21
EAN-8 ........................................................22-23
Code 93 ..........................................................24
Interleaved 2 of 5 ............................................25
Codabar......................................................26-27
MSI/Plessey ....................................................28
PDF417............................................................29
Bar Code Test Symbols....................................................30-33
Specifications ........................................................................34
Product Support, Warranty....................................................35
ASCII Code Table ..................................................................36
Downloaded from www.Manualslib.com
manuals search engine
Chapter 1
Introduction
Bar coding is the most common Automated Data Collection (ADC) technology providing timely, error-free information that can be used to increase productivity, accuracy, and efficiency in the workplace. Virtually every type of industry is using bar codes to replace keyboard data entry. Studies have shown that a proficient data entry operator will make one error for every 300 characters that are manually entered. The error rate using bar codes is almost negligible and can be error-free using bar code symbologies with the check digit enabled.
The Wasp Charged Coupled Device (CCD) technology is a technique whereby a bar code is photographed, digitized, and electronically sampled by built-in photodetectors. The detectors process the measurement of every bar and space using the number of adjacent photodetectors which contrast a black mark and a white space. Wasp WLP 4170 CCD is extremely rugged since it has no moving parts. Wasp WLP 4170 CCD reader supports PC AT/XT and PS/2 keyboard interfaces and easily wedges between the computer and keyboard.
Bar code data is passed directly into the keyboard buffer as if it had been typed in by hand by a data entry operator.
Of all the hand held bar code scanning devices on the market, the CCD reader is the easiest to use and most cost effective for the typical business user. To activate the scanner, the user simply points the scanning aperture towards the bar code, pulls the trigger, and aims the red LED beam across the bar code.
Downloaded from www.Manualslib.com
manuals search engine
1
Chapter 2
Installation
Keyboard
Y-Cable
Scanning Aperture
Din-6M
Din-5F
1.
Turn off your computer.
2.
Unplug your PC keyboard cable and plug the male end (Din 5) of the Wasp
WLP 4170 CCD Scanner directly into your PC keyboard port. Plug your keyboard cable into the other end (female Din 5) of the the Wasp WLP
4170 CCD Scanner. If your keyboard and PC support a Din 6 connection, use the enclosed Din 5 to Din 6 converter cable to connect to the keyboard power tap cable.
3.
Turn your computer on.
2
Downloaded from www.Manualslib.com
manuals search engine
Chapter 3
Quick Start
Your Wasp WLP 4170 CCD Scanner is ready to go. The default settings of the
Wasp WLP 4170 CCD Scanner have been pre-programmed for the most common bar code configurations. Use the "Setup & Configuration" sections only to customize the Wasp settings.
Tip: Use the pre-printed "Bar Code Test Symbols" in Appendix A on page 30 as a test chart to begin practicing scanning.
Downloaded from www.Manualslib.com
manuals search engine
3
Chapter 4
Bar Code Symbologies
Bar codes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commercial products. The bars and spaces in each symbol are grouped in such a way to represent a specific
ASCII character or function. The interpretation of these groups is based on a particular set of rules called symbologies. Various symbologies have been developed for particular applications. Some examples are shipping and receiving, manufacturing, retail, healthcare, transportation, document processing and tracking, and libraries.
The resolution of a bar code is dependent on the narrowest element of a bar code (X dimension), and can vary from high density (nominally less than 0.009
in./0.23 mm), medium density (between 0.009 in./0.23 mm and 0.020 in./0.50
mm), and low density (greater than 0.020 in./0.50 mm). Medium and low densities are the most common since these are the easiest to read (scan) with nearly all scanning devices. Wasp WLP 4170 CCD Scanner can read bar codes with X-dimensions as low as 4 mils (0.10mm).
Wasp WLP 4170 CCD Scanner can read the most popular linear bar code symbologies including Code 39, Code 93, Code 128, Interleaved 2 of 5, UPC-A,
UPC-E, EAN/JAN-8, EAN/JAN-13, Codabar, and MSI Plessey, and also the 2D bar code symbology PDF417.
Please see test chart on pages 30-33.
Downloaded from www.Manualslib.com
manuals search engine
4
Chapter 5
Setup
&
Configuration
In order to configure Wasp WLP 4170 CCD Scanner, you must familiarize yourself with the setup procedures on the following pages. The default settings of Wasp WLP 4170 CCD Scanner are identified on each page and clearly marked using an asterisk (*). The default settings have been preprogrammed
for the most common bar code configurations. Use the Setup &
Configuration only to customize the Wasp settings. If you need to configure
Wasp WLP 4170 CCD Scanner, the default settings will be overwritten.All the programmed settings are stored permanently in non-volatile memory. Therefore, your configuration will be maintained even if keyboard power to Wasp WLP 4170
CCD Scanner is removed by turning off your PC.
In order to configure Wasp WLP 4170 CCD Scanner, seven basic steps need to be followed for each programmed setting:
(1) Determine what, if any, options on EACH PAGE that you wish to change.
(2) Scan the "Begin" bar code. WLP 4170 CCD Scanner will sound an ascending tone to indicate that setup is in progress.
(3) Scan the bar code representing the option to be changed.
(4) Scan the bar codes representing the option values (e.g. 01, 02, 3A etc.).
These option values can be found on the inside back cover flap of this manual. You must scan two digits for each option setting.
(5) Repeat the above two steps, if necessary, to change the options in the same group.
(6) Scan the “Set” bar code on the back cover flap to confirm your selections.
(7) Scan the "Exit" bar code to exit the group currently selected. Wasp WLP
4170 CCD Scanner will sound a descending tone.
NOTE: Pages 6 and 7 are designed as walk through example pages. Use these pages as examples on how to change an option for the rest of the manual.
5
Downloaded from www.Manualslib.com
manuals search engine
Setup & Configuration
—Factory Default
Tip: Use this configuration to restore the factory default settings if you are unsure how your scanner has been configured. The 'Factory Default' configuration is very useful when you need to reprogram your Wasp
WLP 4170 CCD Scanner after the defaults have been changed. By setting the default configuration, the user knows precisely the configuration for each programmed setting.
1. Scan “Begin ”
Begin
2. Scan “Default” to restore scanner to default settings
Default
NOTE: Scanning these bar codes returns the scanner to the factory default settings
Downloaded from www.Manualslib.com
manuals search engine
6
Setup & Configuration
—Beep and Delay
The 'Beep Volume' configuration changes the volume of the audible indicator of the WLP 4170 CCD Scanner.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
1. Scan “Begin ”
Begin
2. Scan “Set Beep Volume”
3. Pick a setting from the table at right, then turn to the back cover flap and scan the corresponding two digits. For example: if you desire no beep, scan 0 and
0 on the back cover flap
Set Beep Volume
Beep Volume Settings
00
01
02
03
04
05
06
07
None
Lowest
Low
Medium (Default)
Medium-High
High
High-Medium
Highest
4. Scan the “Set” barcode on the back cover flap
5. Scan the “Exit” barcode
Exit
7
Downloaded from www.Manualslib.com
manuals search engine
Setup & Configuration
—Intercharacter Delay
The 'Intercharacter Delay' configuration sets the speed at which the WLP 4170
CCD Scanner sends data. The intercharacter delay should be changed only if the transfer rate cannot be maintained between WLP 4170 CCD Scanner and the keyboard buffer of the computer.
Note: The default for the intercharacter delay is set to '2ms' and is the most common configuration; however, your PC may be different.When you scan a bar code, if some characters are missing, decrease the intercharacter delay speed to speed up the transfer rate. If some stray or scrambled characters appear on your screen, increase the intercharacter delay to slow down the transfer rate.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Set Intercharacter
Delay
Intercharacter Delay Settings
00
01
02
50
75
99
Slowest
Slow
Default
Medium
Fast
Fastest
Exit
Downloaded from www.Manualslib.com
manuals search engine
8
Setup & Configuration
—Keyboard Wedge
The 'Keyboard Wedge' configuration supports options related to managing keyboard operations. The 'Function Code' option enables/disables support for your keyboard function keys. The 'Caps Lock' option toggles the case sensitivity of your keyboard.The ‘Laptop/No Keyboard’ setting should be enabled if you are connecting this scanner to a laptop or to a PC with no keyboard.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Set Function Code
Set Caps Lock
Set Laptop/No Keyboard
Function Code Settings
00
01
Off*
On
Caps Lock Settings
00
01
Caps Lock On
Caps Lock Off*
Laptop/No Keyboard Settings
00
01
Keyboard Present*
Laptop/No keyboard
Exit
Downloaded from www.Manualslib.com
manuals search engine
9
*Default
Setup & Configuration
—Scanning Modes
The 'Scanning Mode' option controls the trigger and LED settings for the WLP
4170 CCD Scanner.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
00 Default*
Set Scanning Mode
Continuous Mode
When this option is selected, the LEDs are visible at all times. Under this option, you cannot read the same bar code back-to-back.
* Trigger with 10 Sec. Delay
This is the default option for the
Wasp WLP 4170 CCD Scanner.
When this option is selected, the scanner will stop scanning when there is a successful read or no code is scanned after 10 seconds.
04 Continuous
Exit
Downloaded from www.Manualslib.com
manuals search engine
10
*Default
Setup & Configuration
—Preamble and Postamble
The 'Preamble' and 'Postamble' options are used to add prefix and suffix characters to the bar code value. Up to 22 characters may be added for each option separately.
Note: This example illustrates how data will be fo rmatted when each option is configured.
Preamble
Data Stream Example
Data Postamble
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Set Preamble
Set Postamble
Preamble
Scan 'Begin'. Scan "Set Preamble" to program preamble. Scan characters from the back cover flap using the ASCII Table on page 36. Scan "Set" on the back cover flap to end.Scan 'Exit'.
Postamble
Scan 'Begin'.Scan "Set Postamble" to program postamble. Scan characters from the back cover flap using the ASCII Table on page 36. Scan "Set" on the back cover flap to end.Scan 'Exit'.
Exit
Downloaded from www.Manualslib.com
manuals search engine
11
*Default
Setup & Configuration
—Code 39
Code 39 is va ri a ble length and is the most frequently used symbology in industri a l bar code systems today and is ex t e n s i vely used within the Department of Defe n s e
( D O D ) . The principal feature is to encode messages using the full alphanu m e ri c c h a racter set.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
Disable
Enable
00
01*
00*
01
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
12
*Default
Setup & Configuration
—Code 39 (cont.)
Standard Code 39 contains only 43 characters (0-9, A-Z, $, /, %, +, -, ., SPAC E ) and can be extended to a 128 character symbology (full ASCII) by combining one of the special characters ($, /, %, +) with a letter (A-Z) to fo rm the characters that are not present in the standard Code 39 symbology.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Set Maximum Length
Set Minimum Length
Format
Start/Stop Transmission
Exit
Downloaded from www.Manualslib.com
manuals search engine
Option
00 - 64
00 - 64
Standard
Full ASCII
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00 - 64
00*
00 - 64
00*
00*
01
00*
01
13
*Default
Setup & Configuration
—Code128
Code 128 is va ri a ble length and encodes the full 128 ASCII character set. Each character is represented by 11 modules that can be one of four bar widths. Code 128 is the most easily read code with the highest message integrity due to seve ral separate message check routines. C o d e
128 is usually the best choice when implementing a new symbology.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
Disable
Enable
00
01*
00*
01
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
14
*Default
Setup & Configuration
—Code128 (cont.)
Code 128 is the most flex i ble of all the common linear symbologies. It supports alpha and nu m e ric characters easily, has the highest number of characters per inch, and is va ri a ble length.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Set Maximum Length
Set Minimum Length
Option
64 - Minimum
Alpha/Numeric Entry
(Back Flap)
00 - 64
00*
64 - Maximum
Standard
UCC/EAN-128
00 - 64
00*
00*
01
Format
Exit
Downloaded from www.Manualslib.com
manuals search engine
15
*Default
Setup & Configuration
—UPC-A
UPC-A (Universal Product Code-A) is fixed length and is the most common UPC bar code for retail product labeling. It is seen in most grocery stores across the United States. The symbology encodes a 12-digit number.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
(two digits)
00
01*
Disable
Enable
00
01*
Transmit Check Digit
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
16
*Default
Setup & Configuration
—UPC-A (cont.)
The first six digits of the UPC-A bar code are assigned from the Uniform Code Council
(UCC).The next five digits are assigned by the manufacturer, and the final digit is a modulo
10 check digit.The nominal height for the UPC-A bar code is one inch.The reduced size is
80% of the nominal size.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Supplement Digits
Option
None
2 digits
5 digits
2 / 5 digits or None
Alpha/Numeric Entry
(Back Flap)
00*
01
02
03
Disable
Enable
00*
01
Truncate Leading Zero
Exit
Downloaded from www.Manualslib.com
manuals search engine
17
*Default
Setup & Configuration
—UPC-E
UPC-E (Universal Product Code-E) is fixed length and is a compressed six digit code used for marking small packages, including magazines and paperback books. UPC-E symbols are UPC-A symbols that have been zero suppressed (i.e. consecutive zeros are not included in the symbol).
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
Disable
Enable
00
01*
00
01*
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
18
*Default
Setup & Configuration
—UPC-E (cont.)
The printed value of the UPC-E code is a twelve digit code. The nominal height for the UPC-
E bar code is one inch.The reduced size is 80% of the nominal size.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Supplement Digits
Truncate Leading Zero
Expansion
Option
None
2 digits
5 digits
2 / 5 digits or None
Alpha/Numeric Entry
(Back Flap)
00*
01
02
03
Disable
Enable
Disable
Enable
00*
01
00*
01
Exit
Downloaded from www.Manualslib.com
manuals search engine
19
*Default
Setup & Configuration
—EAN-13
The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology, but encodes a 13th digit. The nominal height for the
EAN/JAN-8 bar code is one inch.The reduced size is 80% of the nominal size.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
Disable
Enable
00
01*
00
01*
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
20
*Default
Setup & Configuration
—EAN-13 (cont.)
The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology, but encodes a 13th digit. The nominal height for the
EAN/JAN-8 bar code is one inch.The reduced size is 80% of the nominal size.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Supplement Digits
Truncate Leading Zero
Convert to ISBN/ISSN
Option
None
2 digits
5 digits
2 / 5 digits or None
Alpha/Numeric Entry
(Back Flap)
00*
01
02
03
Disable
Enable
Disable
Enable
00*
01
00*
01
Exit
Downloaded from www.Manualslib.com
manuals search engine
21
*Default
Setup & Configuration
—EAN-8
The EAN/JAN-8 is fixed length and is similar to the UPC-E code, but includes two more digits for the country code. The nominal height for the EAN/JAN-8 bar code is one inch.The
reduced size is 80% of the nominal size.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
Disable
Enable
00
01*
00
01*
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
22
*Default
Setup & Configuration
—EAN-8 (cont.)
The EAN/JAN-8 is fixed length and is similar to the UPC-E code, but includes two more digits for the country code. The nominal height for the EAN/JAN-8 bar code is one inch.The
reduced size is 80% of the nominal size.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Supplement Digits
Truncate Leading Zero
Expansion
Option
None
2 digits
5 digits
2 / 5 digits or None
Alpha/Numeric Entry
(Back Flap)
00*
01
02
03
Disable
Enable
Disable
Enable
00*
01
00*
01
Exit
Downloaded from www.Manualslib.com
manuals search engine
23
*Default
Setup & Configuration
—Code 93
Code 93 encodes the full 128 ASCII character set using 9 modules arranged into 3 bars with adjacent spaces. Two of the characters are check chara c t e r s. Code 93 is similar to Code 39 bu t encodes more characters per inch. Code 93 encodes the full 128 ASCII character set and is encoded similarly to the extended Code 39.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Set Maximum Length
Disable
Enable
(two digits)
Disable
Enable
64 - Minimum
00 - Maximum
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00*
01
00
01*
00*
01
64 - 00
00*
00 - 64
00*
Set Minimum Length
Exit
Downloaded from www.Manualslib.com
manuals search engine
24
*Default
Setup & Configuration
—Interleaved 2 of 5
I n t e rl e aved 2 of 5 is a va ri a ble length, even numbered, nu m e ric bar code. It is typically used in i n d u s t rial and master carton labeling and also in the automobile industry. The symbology uses bars to represent the first digit of a pair and the interl e aved (white) spaces to represent the second digit of a character pair. See page 24 for info rmation on setting the minimum and m a x i mum lengths.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00
01*
Disable
Enable
Disable
Enable
00
01*
00*
01
Exit
Downloaded from www.Manualslib.com
manuals search engine
25
*Default
Setup & Configuration
—Codabar
Codabar is a variable length symbology capable of encoding six special alphanumeric characters, capital letters A through D, T, N, *, E, and all numeric digits. Codabar is one of the oldest bar code symbologies and is still used in some library applications. It should not be considered for new applications except under unusual circumstances.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Set Maximum Length
Exit
(continued on next page)
Downloaded from www.Manualslib.com
manuals search engine
Option
Disable
Enable
Disable
Enable
Disable
Enable
64 - minimum
Alpha/Numeric Entry
(Back Flap)
00
01*
00*
01
00*
01
64 - 00
00*
26
*Default
Setup & Configuration
—Codabar (cont.)
Codabar is a variable length symbology capable of encoding six special alphanumeric characters, capital letters A through D, T, N, *, E, and all numeric digits. Codabar is one of the oldest bar code symbologies and is still used in some library applications. It should not be considered for new applications except under unusual circumstances.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Set Minimum Length
Start/Stop Type
Start/Stop Transmission
Option
00 - Maximum
Alpha/Numeric Entry
(Back Flap)
00 - 64
00*
ABCD/ABCD abcd/abcd
ABCD/TN*E
Abcd/tn*e
00*
01
02
03
Disable
Enable
00*
01
Exit
Downloaded from www.Manualslib.com
manuals search engine
27
*Default
Setup & Configuration
—MSI Plessey
MSI Plessey is a variable length numeric symbology and is primarily used in marking retail shelves. Each character consists of four bars with intervening spaces for each encoded digit, one or two symbol check digits, and a reverse start code.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
On/Off
Verify Check Digit
Transmit Check Digit
Set Maximum Length
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00*
01
Disable
Mod 10
Mod 10/10
Mod 11/10
Disable
Enable
64 - Minimum
00*
01
02
03
00*
01
64 - 00
00*
00 - Maximum 00 - 64
00*
Set Minimum Length
Exit
Downloaded from www.Manualslib.com
manuals search engine
28
*Default
Setup & Configuration
—PDF417
PDF417 is a 2D variable length symbology that can encode virtually any letter, number, or character. Each character consists of 4 bars and 4 spaces in a 17 module structure. The name of the symbol is derived from the format of the code. PDF stands for "Portable Data
File" and "417" is derived from the module structure. Each PDF417 symbol consists of 3 to
90 stacked rows surrounded by a quiet zone on all four sides. Each row consists of a leading quiet zone, start pattern, left row indicator character, one to thirty data characters, right row indicator character, stop pattern, and trailing quiet zone.
PDF417 supports text compaction, numeric compaction, and byte compaction that correlate the mapping between code word values and decoded data. PDF417 can accommodate up to 340 characters per square inch with a maximum data capacity of 1850 text characters.
NOTE: For help in configuring these settings, consult the programming steps on page 5.
Begin
Option
Disable
Enable
Alpha/Numeric Entry
(Back Flap)
00*
01
On/Off
Exit
Downloaded from www.Manualslib.com
manuals search engine
29
*Default
Setup & Configuration
—Bar Code Test Symbols—Appendix A
Note: Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan. Use the 'Bar Code Symbologies' configuration beginning on page 14 to enable specific symbologies.
Code 39*
Code 93*
Interleaved 2 of 5
Codabar*
Code 128*
MSI/Plessey
Downloaded from www.Manualslib.com
manuals search engine
30
*Default
Setup & Configuration
—Bar Code Test Symbols—Appendix A (cont.)
UPC-A*
UPC-A w/5 digit supplement
UPC-A w/2 digit supplement
UPC-E*
UPC-E w/5 digit supplement
UPC-E w/2 digit supplement
Downloaded from www.Manualslib.com
manuals search engine
31
*Default
Setup & Configuration
—Bar Code Test Symbols—Appendix A (cont.)
EAN/JAN 13*
EAN/JAN 13 w/5 digit supplement
EAN/JAN 13 w/2 digit supplement
Downloaded from www.Manualslib.com
manuals search engine
3
*Default
Setup & Configuration
—Bar Code Test Symbols—Appendix A (cont.)
EAN/JAN 8*
EAN/JAN 8+5 w/5 digit supplement
EAN/JAN 8 w/2 digit supplement
PDF417
Downloaded from www.Manualslib.com
manuals search engine
33
*Default
Setup & Configuration
—WLP 4170 CCD Specifications
WLP 4170 MODEL
OPTICAL
Scanning Width
Depth of Field
Scan Rate
ELECTRICAL
Light Source
Sensor
Operating Voltage
Current Consumption
3.2 in (120 mil)
0 to 3 in (0 to 200 mil)
200 scans / second
660 nm red visible LED
2,048 pixel CCD array
+5 VDC ± 0.25V
Standby 100 mA @ 5 VDC / Sleep 25 mA @ 5 VDC
Operating 180 mA @ 5 VDC
MECHANICAL
Dimensions
Weight
Cable
W3.5" x T4.5" x H7.2"
150 g (without cable)
6 ft
ENVIRONMENTAL
Operating Temperature 0˚C to 40˚C
Storage Temperature
Relative Humidity
Safety Certification
-40˚C to 60˚C
5% to 90% non-condensing
Conforms FCC Class A and CE requirements
Downloaded from www.Manualslib.com
manuals search engine
34
O
UTER
D
IMENSIONS
Product Support
If you experience any problems with Wasp WLP 4170 CCD Scanner that you are unable to resolve, call for technical assistance at (214) 547-4100, Monday through Friday, 8:00 AM - 5:00 PM Central Standard Time. Our web site is
www.waspbarcode.com
You may also contact us in writing at:
Wasp Technologies
1400 10th Street
Plano, TX 75074
(214) 547-4100
(214) 547-4101 Fax
Warranty Information
Wasp Bar Code products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions.
This warranty is limited to repair or replacement at Wasp Bar Code's option, with reasonable promptness after being notified. These provisions do not prolong the original warranty term for any product which has been repaired or replaced by Wasp Bar Code.
This warranty applies to the original owner and does not extend to any
product which has been subject to misuse, neglect, accidental damage, unauthorized repair, or tampering.
No other express warranty is given. The replacement or repair of a product is your exclusive remedy. Any other implied warranty of merchantability or fitness is limited to the duration of this written warranty. Some states, provinces, and countries do not allow how long an implied warranty lasts, so the above limitation may not apply to you.
In no event shall Wasp Bar Code be liable for consequential damages. S o m e s t a t e s, prov i n c e s, and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to yo u .
35
Downloaded from www.Manualslib.com
manuals search engine
ASCII Code Table
Code ASCII
ASCII Preamble/Postamble Code Table
Code ASCII Code ASCII Code ASCII
00 Null
01 Up
02 Down
03 Left
04 Right
05 PgUp
06 PgDn
08 BS
09 Tab
0B Home
0C End
0D Enter
0E Insert
0F Delete
11 F1
12 F2
13 F3
14 F4
15 F5
16 F6
17
18
F7
F8
19 F9
1A F10
1B ESC
1C F11
1D F12
1E Ctrl+
1F Alt+
20 Space
21 !
22 “
#
$
%
‘
&
(
)
★
+
5
6
3
4
7
8
9
0
/
1
2
.
-
:
;
<
=
>
?
@
A
B
S
T
U
V
O
P
Q
R
W
X
[
Y
Z
43
44
45
46
47
48
49
4A
4B
4C L
4D M
4E N
J
K
H
I
E
F
G
C
D
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
53
54
55
56
4F
50
51
52
`
_
^
] a b
3F
40
41
3A
3B
3C
3D
3E
42
30
31
32
2B
2C
2D
2E
2F
33
34
35
36
37
38
39
23
24
25
26
27
28
29
2A
68
69
6A
6B
6C
6D
6E
63
64
65
66
67
73
74
75
76
6F
70
71
72
77
78
79
7A y z w x
7B
7C
7D
7E ~
7F Delete t s u v r q o p k j i h l m n e g f c d
36
Downloaded from www.Manualslib.com
manuals search engine
8
Downloaded from www.Manualslib.com
manuals search engine
9
6
7
4
5
2
3
0
1
C
D
A
B
E
F
FINISH
BACK COVER
BAR CODES
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Introduction
- 5 Installation
- 6 Quick Start
- 7 Bar Code Symbologies
- 8 Setup & Configuration
- 9 1. Factory Default
- 10 2. Beep and Delay
- 11 3. Intercharacter Delay
- 12 4. Keyboard Wedge
- 13 5. Scanning Modes
- 14 6. Preamble/Postamble Configuration
- 15 5. Bar Code Symbology
- 19 UPC-A
- 21 UPC-E
- 28 Interleaved 2 of
- 29 Codabar
- 31 MSI/Plessey
- 33 Bar Code Test Symbols
- 37 Specifications
- 38 Product Support, Warranty
- 39 ASCII Code Table