White-Rodgers 1F85-0477 thermostat Installation and operating instructions
White Rodgers 1F95-0477 is a programmable thermostat with a wide range of features that can help you save energy and improve your comfort. Some key features include:
- 7-day programming: The thermostat can be programmed to different temperatures for each day of the week, so you can set it to be warmer when you're home and cooler when you're away.
- Automatic heat/cool changeover: The thermostat will automatically switch between heating and cooling modes based on the temperature you set, so you don't have to worry about manually changing it.
- Multi-stage operation: If you have a multi-stage heating or cooling system, the thermostat can control up to two stages of heating and two stages of cooling, providing more precise temperature control.
Advertisement
Advertisement
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
Blue 4” Universal Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage, Multi-Stage or Heat Pump
Installation and Operating Instructions for Model:
Model
1F85-0477 7 Day
Programming Choices
5/1/1 Day
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
Description
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Systems with up to 2 Stages Heat, 2 Stages Cool
Heat Only Systems (with optional fan switch)
Millivolt Heat Only Systems – Floor or Wall Furnaces
Cool Only Systems
Gas or Oil Heat
Electric Furnace
Hydronic (Hot Water) Zone Heat – 2 Wires
Hydronic (Hot Water) Zone Heat – 3 Wires
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1F85-0477 Thermostat
SPECIFICATIONS
Electrical Rating:
Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire ................................................... 20 to 30 VAC
Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Rated Differentials: Fast Med. Slow
Heat (SS1, MS2) ............................................... 0.4 °F 0.6 °F
Cool (SS1, MS2) ................................................ 0.9 °F 1.2 °F
Heat Pump (HP1, HP2) ..................................... 0.9 °F 1.2 °F
Emer (HP1, HP2) ............................................... 0.6 °F –
1.7 °F
1.7 °F
1.7 °F
1.7 °F
Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3-7/8”H x 5-1/8”W x 1-1/4”D
!
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Index
Installation
Wiring Connections
Wiring Diagrams
Thermostat Quick Reference
Installer Configuration Menu
Operating Your Thermostat
Programming
Troubleshooting
Page
6
8
9
10
3
5
2
2
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product may replace a product that contains mercury.
Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container. Refer to www.white-rodgers.com for location to send product containing mercury.
PART NO. 37-7238A
www.white-rodgers.com
www.emersonclimate.com
INSTALLATION
!
WARNING
Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code.
Figure 1 – Battery door shown open
“AA” Alkaline Batteries
Remove Old Thermostat
A standard heat/cool thermostat consists of three basic parts:
1. The cover, which may be either a snap-on or hinge type.
2. The base, which is removed by loosening all captive screws.
3. The switching subbase, which is removed by unscrewing the mounting screws that hold it on the wall or adapter
plate.
label each wire with the terminal designation from
which it was attached. Disconnect the wires from the old thermostat one at a time. Do not let wires fall back into the wall.
Installing New Thermostat
1. Pull the thermostat body off the thermostat base. Forcing or prying on the thermostat will cause damage to the unit.
2. Place base over hole in wall and mark mounting hole locations on wall using base as a template.
3. Move base out of the way. Drill mounting holes. If you are using existing mounting holes and the holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure the base.
4. Fasten base snugly to wall using mounting holes shown in Figure 2 and two mounting screws. Leveling is for appearance only and will not affect thermostat operation.
5. Connect wires to terminal block on base.
6. Push excess wire into wall and plug hole with a fire resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.
7. Carefully line the thermostat up with the base and snap into place.
Batteries
2 “AA” alkaline batteries are included with the thermostat.
To install the batteries, pull the battery door as shown by the arrow and lift open. Using the polarity indicated inside the battery door, insert the batteries. To close the battery door, swing the door down while pulling in the direction of arrow. Once fully down, snap the door back into position. To replace the batteries, set system to OFF.
Thermostat can be powered by system AC power or Battery.
If is displayed, the thermostat is battery powered. If is not displayed, thermostat is system powered with optional battery back-up. When battery power remaining is approximately half, the will be displayed. When “Change ” is displayed, install fresh “AA” alkaline batteries immediately.
For best results, replace all batteries with new premium brand alkaline batteries such as Duracell ® or Energizer ® . We recommend replacing batteries every 2 years. If the home is going to be unoccupied for an extended period (over 3 months) and
is displayed, the batteries should be replaced before leaving. When less than two months of battery life remain, the setpoint temperature will offset by 10 degrees (10 degrees cooler in Heat mode / 10 degrees warmer in Cool mode). If offset occurs, the normal setpoint can be manually reset with
or . Another offset will occur within two days if batteries are not replaced.
Figure 2 – Thermostat base and rear view of thermostat
Mounting
Hole
Place Level across
Mounting Tabs
(for appearance only)
Mounting
Hole
Place Level across
Mounting Tabs
(for appearance only)
WIRING CONNECTIONS
Refer to equipment manufacturers’ instructions for specific system wiring information. After wiring, see CONFIGURATION section for proper thermostat configuration. Refer to figure 3 through 6 for wiring diagram specifications.
TERMINAL DESIGNATION DESCRIPTIONS
Terminal
Designation Description
L .............. Heat pump malfunction indicator for systems
with malfunction connection
O .............. Changeover valve for heat pump energized
constantly in cooling
B .............. Changeover valve for heat pump energized
constantly in heating
Y .............. Compressor Relay
Y2 ............. 2nd Stage Compressor
Terminal
Designation Description
W/E ............Heat Relay/Emergency Heat Relay (Stage 1)
W2 .............2nd Stage Heat (3rd Stage Heat in HP 2)
G ..............Fan Relay
RH .............Power for Heating
RC .............Power for Cooling
C ..............Common wire from secondary side of cooling system
transformer or heat only system transformer
6...............3 Wire Zone Valve – Energized when no call for Heat
2
WIRING DIAGRAMS
Heat Pump Connections
If you do not have a heat pump system, refer to figures 4-6.
Refer to equipment manufacturers’ instructions for specific system wiring information.
You can configure the thermostat for use with the following heat pump systems.
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup.
HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two compressor system with gas or electric backup.
After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration.
L
O/B
System
Heat Pump 1
(HP1)
Heat Pump 2
(HP2)
Fault Indicator or System
Malfunction
Switch
O
Energized in
Cool Mode
B
Energized in
Heat, Off,
Emergency
Mode
Comfort Alert II Module or Similar System
Malfunction Module
Y
Figure 3 – Heat Pump Systems
Y2 W/E
Jumper
W2 G
Jumper
RH RC C
Heat and
Cool Mode
1st Stage
(Compressor)
No
Output
2nd
Stage
(Compressor)
Emergency
Mode
1st Stage
Heat Mode
2nd Stage.
Emergency
Mode 2nd
Stage
Heat Mode
3rd Stage.
Emergency
Mode 2nd
Stage
Blower/
Circulator
Fan Energized on Call for
Heat or Cool.
Set Elect/Gas
Option for
Emergency
Mode
24 Volt
(Hot)
Heat
24 Volt
(Hot)
Cool
Optional*
24 Volt
(Common)
NOTE: If your system does not provide an E connection, jumper W2 to W/E to use the Auxiliary Heat in the
Emergency Mode.
* Common connection required for fault or malfunction indication.
NEUTRAL
24VAC
HOT
CLASS II
TRANSFORMER
120VAC
Single Stage and Multi-Stage Connections
Refer to equipment manufacturers’ instructions for specific system wiring information.
This thermostat is designed to operate a single-transformer or two-transformer system.
You can configure the thermostat for use with the following fossil fuel systems:
SINGLE STAGE (SS 1) gas, oil or electric.
MULTI-STAGE (MS 2) gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration.
Figure 4 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer
Jumper
L O/B Y Y2 W/E W2 G RH RC C
System
Single
Stage 1
(SS1)
Multi-
Stage 2
(MS2)
System Malfunction
Module
Fault
Indicator or
System
Malfunction
Switch
O
Energized Constantly in Cool Mode
B
Energized Constantly in Heat, Off,
Emergency
Mode
Cool Mode
1st Stage
No
Output
Cool
Mode
2nd
Stage
No Output
Heat
Mode
1st Stage
Heat Mode
2nd Stage
Blower/
Circulator
Fan Energized on Call for
Cool (and
Heat if configured for Electric
Heat)
24 Volt
(Hot)
Heat
24 Volt
(Hot)
Cool
Optional*
24 Volt
(Common)
NEUTRAL
24VAC
HOT
* Common connection required for fault or malfunction indication.
120VAC
CLASS II
TRANSFORMER
3
WIRING DIAGRAMS
Figure 5 – Single Stage or Multi-Stage System (No Heat Pump) with Two Transformers
L O/B Y Y2 W/E W2 G
Jumper
RH RC
Remove Jumper Wire between RH & RC
C
System
Single
Stage 1
(SS1)
Multi-
Stage 2
(MS2)
Fault
Indicator
(NOT
USED)
O
Energized Constantly in Cool Mode
B
Energized Constantly in Heat, Off,
Emergency
Mode
Cool Mode
1st Stage
No
Output
Cool
Mode
2nd
Stage
No Output
Heat
Mode
1st Stage
Heat Mode
2nd Stage
Blower/
Circulator
Fan Energized on Call for
Cool (and
Heat if configured for Electric
Heat)
24 Volt
(Hot)
Heat
24 Volt
(Hot)
Cool
Optional
24 Volt
(Common)
120VAC
HEATING
CLASS II
TRANSFORMER
NEUTRAL
24VAC
HOT
NEUTRAL
24VAC
HOT
120VAC
CLASS II
TRANSFORMER
COOLING
Y
Figure 6 – 3-Wire (SPDT) Heat Only Zone Valve Wiring
W G
Jumper
RH RC C 6
System
Single Stage
3-wire
Zone Valve application
Closes
Valve
(6)
Opens
Valve
(4)
Blower/Circulator
Fan Energized
24 Volt
(Hot)
Heat
(5)
24 Volt
(Hot)
Cool
Constant
24 Volt
(Common)
NEUTRAL
24VAC
HOT
CLASS II
TRANSFORMER
120VAC
4
THERMOSTAT QUICK REFERENCE
Home Screen Description
Figure 7 – Home Screen Display
Time of day
Room
Temperature
Setting
Temperature
Battery Level Indicator
Indicating the current power level of the 2 “AA” batteries.
Full power remaining.
Half power remaining.
Change The batteries should be replaced at this time with 2 new premium brand
“AA” Alkaline batteries.
(See page 2 for more details)
P
Mo
Set
SYSTEM
Heat
Run
FAN
Auto
Menu
System
Indicator
Fan
Indicator
Programming and Configuration Items
1 “System On” indicates when heating or cooling stage is energized, “+2” flashing indicates when a second stage is energized.
2 The word “Hold” is displayed when the thermostat is in the Hold mode. “ Temp Hold” is displayed when the thermostat is in a Temporary Hold mode.
3 Displays “Change Filter” when the system has run for the programmed filter time period as a reminder to change or clean your filter.
4 Displays “Set” for setpoint when in Run Program mode.
1
5 Displays System Mode (Heat, Em, Auto, Cool, Off) or “Time” in Menu Mode.
6 Displays Fan Mode (On, Auto) in Menu Mode.
7 Displays “Set Schedule”, “Schedule”, or “Menu”.
8 Displays “Save” when Cool Savings TM is working.
9 Displays “Heat Pump” when system is configured as Heat Pump thermostat.
10 Displays “Hold” in programmable mode. When not in
Hold mode, displays “Run” in program run mode.
11 Initially displays “Auto Sched”. If Auto Schedule had been used or disabled, then it displays “Cool Savings” when in the Cool Mode if Cool Savings has been enabled in the menu.
3
9
12
Figure 8 – Programming & Configuration Items
13
Month
Filter
4
Temp Hold
Call For Service Save
Change
System On
Heat Pump
5
+
SYSTEM
Heat Em Auto
Cool OffTime
2
14
Mo Tu We Th Fr Sa Su
P Date
Set
On
FAN
Auto
6
Year
Run Hold
Auto Sched
Cool Savings
Set
Schedule
Menu
7
8
12 “Call For Service” indicates a fault in the heating/ cooling system, it does not indicate a fault in the thermostat.
13 Alternates Time of Day and “LOC” when keypad lockout is enabled.
14 In Configuration Menu, shows screen number. If blank, thermostat is earlier model and requires instruction sheet
37-7050B.
10
11
5
INSTALLER/CONFIGURATION MENU
To enter the Configuration Menu, SYSTEM must be set to HEAT, COOL, Em or AUTO. Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press or
to change an item option.
INSTALLER/CONFIGURATION MENU
MENU
SCREEN
NUMBER
01
MS2/
SS1
HP1/
HP2
DISPLAYED
(FACTORY DEFAULT)
Press or to select from listed options
(OFF) Lk L
02
03
04
(000) Lk
(MS 2)
001 to 999
SS1, HP1, HP2
COMMENTS
Selects Keypad Lockout.
(Not available on earlier models)
Selects Keypad lockout combination number
Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor), or Single Stage (SS 1), Heat Pump 2 (HP 2, 2 compressor or 2 speed compressor)
Select Gas or Electric heat
05
(GAS)
(ELE)
(0) CS
ELE
GAS
1, 2, 3, 4, 5, 6
06
07
08
09
10
11
12
13
14
15
16
17
18
(On) E
(ME)
CR Heat
(ME)
CR Cool
(ME)
CR Heat Pump
(FA)
CR Em
(OFF) CL
Heat-Auto
Cool-Off
(On) dL
0
(current temperature)
°
F
L (90) Heat
L (45) Cool
P7
OFF
SL, FA
SL, FA
SL, FA
SL
CL On
Cool-Off, Heat-Off,
Heat-Fan-Off,
Heat-Cool Auto-Off dL OFF
1 HI, 2 HI, 3 HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
°
C
L 62 to L 89
L 46 to L 82
P3
Selects Cool Savings
Value 1 (low) to 6 (high), Value 0 Disables Feature
Selects Energy Management Recovery (EMR)
On or OFF.
Adjustable Anticipation:
Selects heating cycle rate for MS or SS
Adjustable Anticipation: Selects the cycle rate for cooling (only when MS2 or SS1 is selected in item 1)
Adjustable Anticipation (Heat Pump)
(only when heat pump is selected in #1)
Selects the cycle rate for Emergency mode and Auxiliary stage if Heat Pump is selected in item 1)
Compressor Lockout Time
Select System Switch Configuration with automatic changeover capability
Selects Display Light On or OFF
Adjustable Ambient Temperature Display
19
20
21
22
23
24
25
26
27
MS
HP2
(On) AS Heat
(On) AS Cool
(On) FA Heat
(On) FA Cool
(OFF) CA
(On) dS
(OFF) Change Filter
(200 h) Change Filter
(o) On Cool
OFF
OFF
OFF
OFF
On
OFF
On
25-1975 h
(b) On Heat
Selects Fahrenheit/Celsius Temperature Display
Selects Limited HEAT Range
Selects Limited COOL Range
Defaults for 7 day programming (P7) or 5/1/1 day programming (P3) is available
Automatic Schedule for heat mode.
Automatic Schedule for cool mode.
Fast Heat option may be disabled by selecting OFF. NA to SS config.
Fast Cool option may be disabled by selecting OFF. NA to SS config.
NA to Heat only system.
Selects active Comfort Alert On or OFF.
Require CA II Module. (Not available on earlier models)
Selects Automatic daylight Savings Time option On or OFF.
Selects Filter Change-out Indicator On or OFF.
Change Filter time in 25 hour increments. This menu only appears if On is selected in above.
Selects operation of the reversing valve terminal (O/B) output as an O or B terminal.
6
INSTALLER/CONFIGURATION MENU
1 & 2) Keypad Lockout – This menu selection will display
“ Lk” and “OFF” (default, keypad not locked out). The
and are used to toggle the selection between
OFF and “L” (keypad locked out). When the keypad lockout selection is enabled “L”, and the MENU button is pressed again, the display will indicate the number
“0” (default, still disabled) in the time digits. The and are used to set the combination number from 0 to 999. If a combination of 0 is selected and the MENU button is pressed, the menu will be exited and keypad will not be locked. If 1 to 999 is selected and the MENU button is pressed, the combination is stored into memory and the menu is exited. The “ Lk” will display designating keypad locked with a valid combination. The SYSTEM button will operate for 10 seconds after the menu mode is exited to allow the user to change the mode from
“ OFF” to the desired SYSTEM mode.
While the keypad is locked out, a press of MENU will enter the configuration menu. The first menu item displayed is the combination code “ 0”. The or keys are used to set the combination unlock number from 0 to
999. If the unlock number matches exactly with the combination lock number stored in memory when the MENU button is pressed, the keypad is unlocked and the “Loc” is removed. If the unlock number does not match when the MENU button is pressed, the combination returns to
“0” for another attempt to set the unlock code. To exit the menu without unlocking the keypad, press RUN SCHED.
To reset the combination code and unlock the keypad if the code is forgotten, see troubleshooting section.
3) This control can be configured for:
MS 2 – Multi-Stage System (no heat pump)
HP 1 – Heat Pump with one stage of compressor
HP 2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup
SS 1 – Single Stage System
4) GAS or Electric (ELE) fan operation. If the heating system requires the thermostat to energize the fan, select
ELE. Select GAS if the heating system energizes the fan on a call for heat.
5) Select Cool Savings™ value – Selects the amount of adjustment for the Cool Savings™ feature in Cool mode with 1 (1°) being the least amount of adjustment and 6 (6°) being the most amount of adjustment. Default value is 0 which disables this feature. Selecting a value greater than 0 will display Cool Savings on the screen and enable the key for Cool Savings feature. Cool Savings is an optional energy saving feature that can reduce your cooling costs. It is based on the principal that lower indoor humidity makes a slightly higher temperature feel more comfortable. Cool Savings operates during periods of high demand which normally occur on the hottest summer days when a cooling system may run for hours to reach the thermostat setting. Long cooling run times also lower the indoor humidity. Cool Savings, very slowly, adjusts the setpoint temperature to make the setpoint closer to the displayed room temperature, to a maximum of the number of degrees you select. Adjusting the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off. The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature.
To turn this feature on in the Cool mode press Cool
Savings. The display will show “Save” next to the setpoint temperature. When Cool Savings is making adjustments to the room temperature display “Save” will be flashing and the displayed room temperature may vary within the adjustment range you selected.
“Save” is not displayed and this feature is OFF, no change will occur when the cooling system is continuously running during periods of high demand.
6) Energy Management Recovery: Energy Management
Recovery (E) On enables the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start approximately 5 minutes early for every 1° of temperature required to reach setpoint.
Example: E On is selected and your heating is pro- grammed to 65° at night and 70° at 7 AM. If the building temperature is 65°, the difference between 65° and
70° is 5°. Allowing 5 minutes per degree, the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per degree, because it takes longer to reach set temperature.
7, 8,9 & 10) Cycle Rate Selection – The factory default setting for Heat and Cool modes, SS1, MS2, is medium cycle (ME). For Heat Pump, HP1, HP2, the default setting is medium (ME). For Emer (Aux) the default setting is fast cycle (FA). To change cycle rate, press the
key.
or
Cycle rate differentials for different settings are:
Fast
MODE
Medium
FA
Heat (SS1, MS2)
Cool (SS1, MS2)
0.4°F 0.6°F 1.7°F
0.9°F 1.2°F 1.7°F
Heat Pump (HP1, HP2) 0.9°F 1.2°F 1.7°F
Emer (HP1, HP2) 0.6°F - 1.7°F
11) Select Compressor Lockout CL OFF or ON – Selecting CL ON will cause the thermostat to wait 5 minutes between cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs, it will flash the setpoint for up to five minutes.
12) System Mode Configuration – This thermostat is configured for Heat and Cool (SYSTEM switch with Cool,
Off, Heat) default. It can also be configured for Heat and
Cool with Auto changeover (Heat, Auto, Cool, Off), Heat only with fan (Off, Heat), Heat only without fan, Auto only
(Auto, Off), and Cool only (Cool, Off).
13) Select Backlight Display – The display backlight improves display contrast in low lighting conditions. When the “C” terminal is powered, selecting backlight CdL ON will keep the light on continuously. Select backlight OFF will turn the light on momentarily after any key is pressed.
When the “C” terminal is not powered, the light will be on momentarily after any key is pressed no matter whether the backlight is selected ON or OFF.
14) Select Temperature Display Adjustment 4 LO to 4 HI
– Allows you to adjust the room temperature display up to 4° higher or lower. Your thermostat was accurately calibrated at the factory, but you have the option to change the display temperature to match your previous thermostat. The current or adjusted room temperature will be displayed.
15) Select F° or C° Readout – Changes the display readout to Celsius or Fahrenheit as required.
16 & 17) Temperature Limit Range Heat or Cool – This selection sets the maximum HEAT (13) or minimum
COOL (14) temperature for the setpoint range. Select the limit temperature using the or keys. In the Run mode, the setpoint temperature will not adjust past the limit temperature selected. When the limit temperature is reached, trying to raise or lower the setpoint past the limit will cause “L” to be displayed in the times digits for about 6 seconds. This feature not available on earlier models.
18) Program Options: Configured for 7 day or 5/1/1 day programming or non-programmable mode. The default setting is P7, indicating 7 day programming. The programs
7
INSTALLER/CONFIGURATION MENU
per week can be changed to P3 by pressing the or
keys. A selection of 0 Days for non-programmable will eliminate the need for EMR, and that step in the menu will be skipped.
19 & 20) Select Automatic Schedule – With just one touch of the AUTO SCHEDULE button this feature allows you to program a desired comfort temperature into all the program periods along with a 6° set back for night periods of both Heat and Cool programs. Factory default is “On” for both. When Heat AS On and Cool AS On are activated while in Heat or Cool mode, select desired setpoint temperature and press AUTO SCHEDULE . This value will be copied into all the morning, day and evening program periods. The night program periods will have a
6°F set back.
21 & 22) Select Fast Second Stage ON or OFF – Heat pump or Multi-stage only, in the run mode, with the fast
Heat feature enabled (FA Heat On), if the Heat setpoint temperature is manually raised by 3°F (2°C) or more above the actual temperature using the second stage will energize immediately. With FA OFF, second stage will not energize until the setpoint temperature is
1°F or more above actual temperature for more than ten minutes. The Fast Cool feature (FA Cool) provides the same controls when the setpoint temperature is lowered.
23) Comfort Alert with Active Protection – Turn this feature ON to enable active protection. This allows the thermostat to identify fault codes sent by the Comfort
Alert module when compressor damage is possible and react to those codes by turning the compressor off. Fault codes from the Comfort Alert module will flash on the thermostat. (Refer to Comfort Alert Yellow Alert Codes in Troubleshooting section.) If a Comfort Alert module is not connected, or to disable active protection, turn this feature OFF. If a Comfort Alert module is connected and this feature is turned OFF, the thermostat will still receive and flash the fault codes from the Comfort Alert module, but the active protection will not be enabled to protect the compressor.
24) Select Daylight Saving Time Calculation – This feature will allow the thermostat to calculate the DST automatically and apply it to the Real Time Clock display. Default
On. Use or buttons to select the feature OFF.
25 & 26) Select Filter Replacement Reminder and Set
Run Time – Select the “Change Filter” reminder On or OFF. If selected On, press MENU to select the time period from 25 to 1975 hours in 25 hours increments.
In a typical system, 200 hours (default) of run time is approximately 30 days. After the selected time of blower operation, the thermostat will display “Change Filter” as a reminder to change or clean your air filter. When
“Change Filter” is displayed, press MENU or RUN button to clear the display and restart the time to the next filter change.
27) Select Reversing Valve Output – The O/B option is factory set at “O” position. This will accommodate the majority of heat pump applications, which require the changeover relay to be energized in COOL. If the thermostat you are replacing or the heat pump being installed with this thermostat requires a “B” terminal, to energize the changeover relay in HEAT, the O/B option should be set at “B” position.
OPERATING YOUR THERMOSTAT
Choose the Fan Setting (Auto or On)
Press the FAN button to Auto or On.
Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on.
Fan On runs the fan continuously for increased air circulation or to allow additional air cleaning.
Choose the System Setting
(Heat, Off, Cool, Auto, Emer)
Press the SYSTEM button to select:
Heat: Thermostat controls only the heating system.
Off: Heating and Cooling systems are off.
Cool: Thermostat controls only the cooling system.
Auto: Auto Changeover is used in areas where both heating and cooling may be required on the same day. AUTO allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than the heating temperature.
Em: (Heat Pump models) Thermostat controls only backup heating system.
Manual Operation (Bypassing the Program)
Programmable Thermostats
Press or and then the HOLD button and adjust the temperature wherever you like. This will override the program.
The HOLD feature bypasses the program and allows you to adjust the temperature manually, as needed. Whatever temperature you set in HOLD will be maintained 24 hours a day, until you manually change the temperature or press RUN to cancel HOLD and resume the programmed schedule.
8
IMPORTANT!
Program Override (Temporary Override)
Press or buttons to adjust the temperature. This will override the temperature setting for two hours minimum or until the next programmed time. To cancel the temporary setting at any time and return to the program, press RUN . If the SYSTEM button is pressed to select AUTO the thermostat will change to Heat or Cool, whichever ran last. If it switches to heat but you want cool, or it changes to cool but you want heat, press both and change to the other mode.
buttons simultaneously to
Second Stage Time Delay
Your thermostat is designed to determine the optimum time to activate the second stage. Simply raising the temperature in heating or lowering it in cooling will not always force the thermostat to bring the second stage on quickly. There is a time delay from 0-30 minutes depending on the performance of the first stage of the system.
EXAMPLE: For the last 2 hours the thermostat is set on 70° and the room temperature is 70° with the equipment using only the first stage of heat. Since the equipment is keeping the temperature within 1° of setpoint, the thermostat will delay second stage for a longer time if you manually raise the temperature or if the room temperature quickly changes.
Once the second stage comes on, it will come on sooner the next time there is a difference between the setpoint and the room temperature. The net effect of the staging program is that when the first stage is capable of making temperature the second stage will delay longer. When the thermostat calculates that first stage cannot make temperature in a reasonable time, the second stage will come on sooner. This built in function automatically optimizes the use of additional stages of heat or cool.
PROGRAMMING
Set Current Time and Date
1) Press Menu and then Time button once. The display will show the hour only.
2) Press and hold either the or button until you reach the correct hour and AM/PM designation (AM begins at midnight, PM begins at noon).
TIME once again. The display window will show the minutes only.
4) Press and hold either the or button until you reach the correct minutes.
5) Additional presses of TIME will advance the display to show the year, month and date of month. Press the or button to change the display to the correct setting for each.
6) Press TIME mode.
Enter the Heating Program
1) Press SYSTEM button to select “Heat” in the system switch area indicating the active mode being programmed.
2) Press the MENU button and then press SCHEDULE.
3) The top of the display will show the day(s) being programmed. The time and temperature (flashing) are also
“1” will also be displayed to indicate the period.
4) Press or button to change the temperature to your selected temperature for the 1st heating period.
6) Press or
1st period.
button to adjust the start time for the
7) The time will change in 15 minute increments.
8) After you have set the time and the temperature for the period to begin, press SCHEDULE to advance to the next program period.
9) Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day.
10) Press SCHEDULE to the next day and repeat steps 2 through 9.
11) When programming is complete and all of the times and temperatures match your desired heating schedule, press
RUN. The thermostat will now run your program.
Enter the Cooling Program
1) Press SYSTEM button to select “Cool” in the system switch area indicating the active mode being pro-
grammed.
Enter Heating Program instructions for entering cooling times and temperatures.
Energy Saving ENERGY STAR
®
Factory Pre-Program
The programmable thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button. The table below shows the factory set heating and cooling schedule for all days of the week.
Heating
Program
Cooling
Program
Wake Up
(Period 1)
6:00 AM 70°F
Leave For Work
(Period 2)
8:00 AM 62°F
Return Home
(Period 3)
5:00 PM 70°F
Go To Bed
(Period 4)
10:00 PM 62°F
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The thermostat comes configured for 7 day programming and can also be configured for 5/1/1 day programming (see configuration section).
Factory settings are listed on Monday through Friday, Saturday and Sunday. If you are re-programming a 7 day schedule, pencil in all lines with the times and temperatures you want.
If you are re-programming a 5+1+1 fill in your own times and temperatures directly below the factory times and temperatures.
Keep the following guidelines in mind when planning your program.
• In Heating, lower temperatures will save energy.
• In Cooling, higher temperatures will save energy.
• If you plan on using Auto Changeover, do not program
the heating higher than the cooling.
9
PROGRAMMING
Worksheet for Re-Programming 7 Day and 5+1+1 Day Program
Heating
Program
Wake Up
(Period 1)
6:00 AM 70°F
Leave For Work
(Period 2)
8:00 AM 62°F
Return Home
(Period 3)
5:00 PM 70°F
Go To Bed
(Period 4)
10:00 PM 62°F
MON
TUE
WED
THU
FRI
SAT
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
SUN
Cooling
Program
Wake Up
(Period 1)
6:00 AM 75°F
MON
TUE
WED
THU
FRI
SAT
6:00 AM 75°F
6:00 AM 75°F
SUN
Leave For Work
(Period 2)
8:00 AM
8:00 AM
8:00 AM
83°F
83°F
83°F
Return Home
(Period 3)
5:00 PM 75°F
5:00 PM
5:00 PM
75°F
75°F
Go To Bed
(Period 4)
10:00 PM 78°F
10:00 PM 78°F
10:00 PM 78°F
TROUBLESHOOTING
Comfort Alert Codes
The Comfort Alert diagnostics product monitors the air conditioning outdoor systems with single phase Copeland
Scroll compressors. Abnormal system and electrical conditions are indicated by flashing ALERT codes on the yellow LED on the Comfort Alert module. The flash codes are transmitted to the thermostat by the Comfort Alert Thermostat interface module. The Comfort Alert compatible thermostat displays “Call For Service” that flashes at the same rate as the yellow LED on the Comfort Alert module.
Comfort Alert Yellow Alert Codes
1 Flash
2 Flashs
3 Flashs
4 Flashs
5 Flashs
6 Flashs
7 Flashs
8 Flashs
9 Flashs
Long run time
System pressure trip
Short cycling
Locked rotor
Open circuit
Open start circuit
Open run circuit
Welded Contactor
Low voltage
10
TROUBLESHOOTING
Reset Operation
Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C
(do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.
Note: Be sure to review the installer configuration menu settings.
To reset the programming, clock and configuration settings, press and and the FAN button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.
Symptom
No Heat/No Cool/No Fan
(common problems)
No Heat
No Cool
Heat, Cool or Fan
Runs Constantly
Thermostat Setting &
Thermostat Thermometer
Disagree
Furnace (Air Conditioner)
Cycles Too Fast or Too
Slow (narrow or wide temperature swing)
Possible Cause
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
3. Furnace blower compartment door or panel loose or not properly installed.
4. Loose connection to thermostat or system.
1. Pilot light not lit.
2. Furnace Lock-Out Condition. Heat
may also be intermittent.
3. Heating system requires service or
thermostat requires replacement.
1. Cooling system requires service or
thermostat requires replacement.
1. Possible short in wiring.
2. Possible short in thermostat.
3. Possible short in heat/cool/fan system.
4. FAN Switch set to Fan ON.
1. Thermostat thermometer setting
requires adjustment.
1. The location of the thermostat and/or
the size of the Heating System may
be influencing the cycle rate.
Correction Action
Replace fuse or reset breaker.
Turn switch to ON.
Replace door panel in proper position to engage safety interlock or door switch.
Tighten connections.
Re-light pilot.
Many furnaces have safety devices that shut down when a lock-out condition occurs. If the heat works intermittently, contact the furnace manufacturer or local HVAC service person for assistance.
Diagnostic: Set SYSTEM Switch to HEAT and raise the setpoint above room temperature. Within a few seconds the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed above. If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly.
Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling.
Check each wire connection to verify they are not shorted or touching together. No bare wire should stick out from under terminal block. Try resetting the thermostat as described above. If the condition persists, the manufacturer of your system or service person can instruct you on how to test the Heat/Cool system for correct operation. If the system operates correctly, replace the thermostat.
The thermometer can be adjusted +/- 4 degrees. See
Temperature Display Adjustment in the Configuration Menu section.
Digital thermostats provide precise control and cycle faster than older mechanical models. The system turns on and off more frequently but runs for a shorter time so there is no increase in energy use. If you would like an increased cycle time, choose SL for slow cycle in the Configuration menu, step 6 (heat), 7 (cool) or 8 (heat pump). If an acceptable cycle rate is not achieved, contact a local HVAC service person for additional suggestions.
Hold MENU key for 20 seconds and the lockout will reset.
Forgot Keypad Lockout
Code
Thermostat does not have
Menu Screen Numbers
1. Earlier version of thermostat. Refer to Instruction Sheet 37-7050B.
11
White-Rodgers is a division of Emerson Electric Co.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
HOMEOWNER HELP LINE: 1-800-284-2925
www.white-rodgers.com
www. emersonclimate.com
Advertisement
Key features
- Single-stage, multi-stage or heat pump
- 7-day or 5/1/1-day programming
- Automatic heat/cool changeover
- Compatible with Comfort Alert modules
- Adjustable anticipation settings
- Filter change reminder
- Backlight display
- Celsius or Fahrenheit temperature display
- Keypad lockout
- Energy Management Recovery