Control�relay,�24VAC,�8DI(2AI),�4DO�relays,�time Part�no. EASY512-AB-RCX Article�no.

Control�relay,�24VAC,�8DI(2AI),�4DO�relays,�time Part�no. EASY512-AB-RCX Article�no.
Control�relay,�24VAC,�8DI(2AI),�4DO�relays,�time
Part�no.
Article�no.
Delivery�programme
EASY512-AB-RCX
274102
Catalog�No.
Product range
Basic function
Description
Inputs
Digital input count
Digital
of which can be used as analog
Outputs
Type
Quantity of outputs
Outputs
Additional features
Display
Supply voltage
Software
Number
Approvals
Product Standards
IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213M1987; CE marking
E135462
NRAQ
012528
2252-01 + 2258-02
UL listed, CSA certified
IEC: IP20, UL/CSA Type: BV
DNV
GL
LR
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification
Degree of Protection
shipping classification
General
Standards
Control relays easyRelay
easy500
Stand alone
customized laser inscription or delivery
with user program possible with EASYCOMBINATION-* product (article No.
2010781)
digital: 8
digital: 8; of which can be used as
analog: 2
8
2
Relay
Relays: 4
4
without display, without keypad
24 V AC
EASY-SOFT-BASIC/-PRO
EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
mm
71.5 x 90 x 58 (4 PE)
kg
0.2
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets
ZB4-101-GF1 (accessories)
Solid
Flexible with ferrule
mm
Standard screwdriver
Dimensions (W x H x D)
Weight
Mounting
Terminal�capacities
Max. tightening torque
Climatic�environmental�conditions
Operating ambient temperature
Condensation
Storage
relative humidity
Air pressure (operation)
Ambient�conditions,�mechanical
03/26/2014
2
0.2/4 (AWG 22 - 12)
mm
2
0.2/2.5 (AWG 22 - 12)
mm
3.5 x 0.8
Nm
0.6
°C
In accordance with IEC 60068-2-1, -25 - +55
Take appropriate measures to prevent condensation
ϑ
°C
-40 - +70
%
in accordance with IEC 60068-2-30, IEC 60068-2-78
5 - 95
hPa
795 - 1080
HPL-ED2014 V2.13 EN
1/6
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15
g/11 ms
Drop to IEC/EN 60068-2-31
In accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150
Impacts 18
mm
50
Free fall, packaged (IEC/EN 60068-2-32)
Drop
height
m
1
Vertical or horizontal
III/2
according to IEC EN 61000-4-2
kV
8
kV
6
V/m
10
EN 55011 Class B, EN 55022 Class B
kV
power pulses (Surge)
according to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
according to IEC/EN 61000-4-5
2 kV (supply cables, symmetrical)
V
10
EN 50178, UL 508, CSA C22.2, No. 142
EN 50178
Back-up of real-time clock
Vibrations
Mounting position
Electromagnetic�compatibility�(EMC)
Overvoltage category/pollution degree
Electrostatic discharge (ESD)
applied standard
Air discharge
Contact discharge
Electromagnetic fields (RFI) to IEC EN 61000-4-3
Radio interference suppression
Burst
Insulation�resistance
Clearance in air and creepage distances
Insulation resistance
Back-up�of�real-time�clock
Backup time (hours) with fully charged double layer capacitor
Service life (years)
Accuracy of real-time clock to inputs
typ. ± 2 (± 0.2 h⁄Year)
s/
day
depending on ambient air temperature fluctuations of up to ± 5 s/day (±
0.5 h⁄year) are possible
%
±1
ms
10
s
1
min
1
1000000 (10⁶)
Ue
V
24 AC
Ue
20.4 - 26.4 V AC
Hz
50/60 (± 5%)
normally 200 mA at 24 V AC 50/60 Hz
ms
≤ In accordance with IEC 61131-2
≤ 20
A
8
2 (I7,I8)
from power supply: no
between digital inputs: no
from the outputs: yes
to interface/memory card: no
Repetition�accuracy�of�timing�relays
Accuracy of timing relays (of values)
Resolution
Range “S”
Range “M:S”
Range “H:M”
Retentive�memory
Write cycles of the retentive memory
Power�supply
Rated operational voltage
Permissible range
Frequency
Input current
Voltage dips
Fuse
Digital�inputs�24�V�DC
Number
Inputs can be used as analog inputs
Potential isolation
03/26/2014
HPL-ED2014 V2.13 EN
1A (T)
2/6
Rated operational voltage
Ue
24
Input voltage (AC = sinusoidal)
V
AC
Ue
V
Rated frequency
Signal 0: 0 - 6 V AC
Signal 1: > 8 V AC / > 11 V DC (I7, I8), 14 - 26.4 V AC (I1 - I6)
Hz
50 - 60
mA
I1 - I6: 4 (at 24 V AC, 50 Hz)
I7, I8: 2 (at 24 V AC/DC)
ms
80⁄66⅔ (0 -> 1/1 -> 0, debounce ON/OFF 50/60Hz, I1 to I8)
m
normally 40 (max. per input)
2 (I7, I8)
from power supply: no
between digital inputs: no
from the outputs: yes
to interface/memory card: no
DC voltage
0-10 V DC
0.01 V analog
0.01 V digital
10 Bit (value 0 - 1023)
kΩ
11.2
%
±3
%
± 2, (I7, I8, I11, I12) ± 0.12 V
ms
Input delay ON: 20; Input delay OFF: each cycle time
mA
<1
m
4
1
Not permissible
Miniature circuit-breaker B16 or fuse 8 A (slow)
from power supply: yes
From the inputs: yes
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
Operations
x
A
8
mA
> 500
A
16
A
16
kV
6
Ue
250
Rated insulation voltage
V
AC
Ui
250
Safe isolation according to EN 50178
V
AC
Making capacity
V
AC
300 between coil and contact
300 between two contacts
Operations
300000
Operations
200000
Operations
300000
Operations
200000
Operations
25000
Operations
25000
Input current at signal 1
Deceleration time
Cable length
Analog�inputs
Number
Potential isolation
Input type
Signal range
Resolution
Input impedance
Accuracy of actual value
Two EASY devices
Within a single device
Conversion time, analog/digital
Input current
Cable length
Relay�outputs
Number
Outputs in groups of
Parallel switching of outputs for increased output
Protection of an output relay
Potential isolation
Lifespan, mechanical
Contacts
Conventional thermal current (10 A UL)
Recommended for load: 12 V AC/DC
Short-circuit-proof cos ϕ = 1, characteristic B16 at 600 A
Short-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A
Rated impulse withstand voltage Uimp of contact coil
Rated operational voltage
AC–-15, 250 V AC, 3 A (600 ops./h)
DC-13, L/R
150 ms, 24 V DC, 1 A (500 S/h)
Breaking capacity
AC-15, 250 V AC, 3 A (600 Ops./h)
DC-13, L/R
150 ms, 24 V DC, 1 A (500 S/h)
Filament bulb load
1000 W at 230/240 V AC
500 W at 115/120 V AC
Fluorescent lamp load
Fluorescent lamp load 10 x 58 W at 230/240 V AC
03/26/2014
30, screened
6
10
HPL-ED2014 V2.13 EN
10
3/6
With upstream electrical device
Uncompensated
Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional,
compensated
Switching frequency
Mechanical operations
Switching frequency
Resistive load/lamp load
Inductive load
UL/CSA
Uninterrupted current at 240 V AC
Uninterrupted current at 24 V DC
AC
Control Circuit Rating Codes (utilization category)
Max. rated operational voltage
max. thermal continuous current cos ϕ = 1 at B 300
max. make/break cos ϕ ≠ capacity 1 at B 300
DC
Control Circuit Rating Codes (utilization category)
Max. rated operational voltage
Max. thermal uninterrupted current at R 300
Max. make/break capacity at R 300
Operations
25000
Operations
25000
Operations
25000
x
Hz
10
Hz
2
Hz
0.5
A
10
A
8
B 300 Light Pilot Duty
V
AC
300
A
5
VA
3600/360
R 300 Light Pilot Duty
V
DC
300
A
1
VA
28/28
6
10
10
Technical�data�ETIM�5.0
PLC's (EG000024) / Logic module (EC001417)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module ([email protected] [AKE539010])
Supply voltage AC 50 Hz
V
20.4 - 26.4
Supply voltage AC 60 Hz
V
20.4 - 26.4
Supply voltage DC
V
0-0
Voltage type of supply voltage
AC
Switching current
A
8
Number of analogue inputs
2
Number of analogue outputs
0
Number of digital inputs
8
Number of digital outputs
4
With relay output
Yes
Number of HW-interfaces industrial
0
Ethernet
Number of HW-interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
0
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation
No
Fieldbus
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface
No
Safety at Work
Supporting protocol for DeviceNet
No
Safety
Supporting protocol for INTERBUS No
Safety
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus
No
systems
Radiostandard Bluetooth
No
03/26/2014
HPL-ED2014 V2.13 EN
4/6
Radiostandard WLAN 802.11
Radiostandard GPRS
Radiostandard GSM
Radiostandard UMTS
IO link master
Redundancy
With display
Degree of protection (IP)
Basic device
Expandable
Expansion device
With timer
Rail mounting possible
Wall mounting/direct mounting
Front build in possible
Rack-assembly possible
Suited for safety functions
Category according to EN 954-1
SIL according to IEC 61508
Performance level acc. to EN ISO
13849-1
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
Explosion safety category for dust
Width
Height
Depth
No
No
No
No
No
No
No
IP20
Yes
No
No
Yes
Yes
Yes
No
No
No
0
-
mm
mm
mm
No
No
None
None
72
90
60
Dimensions
Additional�product�information�(links)
IL05013015Z�(AWA2528-2105)�Control�relay�easy
IL05013015Z (AWA2528-2105) Control
relay easy
ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL05013015Z2010_11.pdf
MN05013003Z-EN�(AWB2528-1508)�control�relay�easy500,�easy700
MN05013003Z-DE (AWB2528-1508)
Steuerrelais easy500, easy700 Deutsch
ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05013003Z_DE.pdf
MN05013003Z-EN (AWB2528-1508)
control relay easy500, easy700 English
ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05013003Z_EN.pdf
Labeleditor
http://downloadcenter.moeller.net/de/software.f6023a63-5acb-42c7-a51c-ccf99091cace
03/26/2014
HPL-ED2014 V2.13 EN
5/6
03/26/2014
Eaton Industries GmbH
http://www.eaton.eu
© 02/2014 by Eaton Industries GmbH
HPL-ED2014 V2.13 EN
6/6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project