red lion CUB5 USB Panel Meter Product manual
Red Lion CUB5 USB is a powerful programming tool that enables you to easily configure and manage your CUB5 meters using a PC. With Crimson software, you can create custom configurations, download and upload programs, and monitor meter data in real-time. The CUB5 USB also allows for remote access to your meters, making it easy to make changes and troubleshoot issues from anywhere with an internet connection.
Advertisement
Advertisement
Bulletin No. CUB5USB-B
Drawing No. LP0770
Released 05/14
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839 www.redlion.net
MODEL CUB5USB - USB PROGRAMMING OPTION CARD
DESCRIPTION
This bulletin serves as a guide for the installation, configuration and operation of the CUB5 USB Programming plug-in card for the CUB5. The plug-in card is a separately purchased option card that plugs into the main circuit board of the meter. The CUB5USB card in conjunction with the Crimson ® programming software enables the user to configure CUB5 on a PC. The CUB5USB requires installation of drivers which are included with the Crimson Programming software. Following installation of the drivers, the card appears as a Virtual communications port.
Crimson is a Windows ® based program that allows configuration of the CUB ® make it easy to program the CUB5 meters. The CUB5 program can then be saved in a PC file for future use. A CUB5 serial plug-in card is required to program the meter using the software.
5 meters from a PC. Crimson offers standard drop-down menu commands, that
INSTALLING PLUG-IN CARDS
The card plugs into the main circuit board of the meter as shown.
Perform USB driver installation below prior to powering the
CUB5 and connecting CUB5USB to a PC USB port.
USB Card
ON ECE
1 2 3 4
SPECIFICATIONS
CUB5USB PROGRAMMING CARD
Type: USB Virtual Comms Port
Baud Rate: 300 to 38.4k
Unit Address: 0 to 99
CRIMSON 2 SYSTEM REQUIREMENTS
• Windows 2000 or later
• RAM and free disk space as required by the chosen operating system.
• A display of at least 800 by 600 pixels
• A USB port for downloading to the CUB5
WARNING: Disconnect all power to the unit before installing Plug-in card.
CAUTION: The Plug-in cards and main circuit board contain static sensitive components. Before handling the cards, discharge static charges from your body by touching a grounded bare metal object. Ideally, handle the cards at a static controlled clean workstation. Also, only handle the cards by the edges. Dirt, oil or other contaminants that may contact the cards can adversely affect circuit operation.
USB DRIVER INSTALLATION
1. Download and install the latest Crimson 2 build on your Windows ® compatible
PC. Earlier builds may not have the RLC Virtual Comm port drivers. Crimson software is available as a free download at http://www.redlion.net.
2. Install CUB5USB card into CUB5 meter and apply power to the CUB5.
3. Connect Type A USB cable to computer and CUB5USB option card.
Windows will prompt you for the location of the drivers for the device. The default location for these drivers is “C:\Program Files\Red Lion controls\
Crimson 2.0\Device.” When the hardware setup appears, choose “Install from a list or Specific location,” click Next, and then check “Include this location...” and click the Browse button. Point the Wizard at the location specified above or whatever other location you specified during installation of the software. It is important that you perform this step correctly, or you may have to manually remove the drivers using the Device Manager, and repeat the installation once more.
Note: Crimson’s USB drivers have not been digitally signed by Microsoft ® , and you will therefore see a dialog offering you the chance to stop the installation. You should be sure to select the Continue option to indicate that you do indeed wish to install the drivers.
4. Windows will automatically assign a comms port to the CUB5USB. To determine the port assigned, open “System Properties” from within Windows ®
Control Panel. Select the Hardware tab, and click the “Device Manager” button. Expand the “Ports” line. Take note of which Comms port is assigned to “RLC Virtual Comm port”. It must be Com4 or lower to operate with
Crimson 2. If higher, right-click on the entry and select “Properties,” “Port
Settings” tab, and then “Advanced” button. Select a Coms port that is COM4 or lower and is not physically being used.
1
ORDERING INFORMATION
MODEL NO. DESCRIPTION
CUB5USB
CBLUSB
SFCRD*
CUB5 USB Programming Card
Type A to B USB Cable
Crimson 2 PC Configuration Software
PART NUMBER
CUB5USB0
CBLUSB00
SFCRD200
* Crimson software is available for download from http://www.redlion.net/
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The
Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify
RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L.
93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.
MODULE 5 - S
EriaL
C
OMMUniCatiOnS
P
araMEtErS
(5-SEr)
PARAMETER MENU 5-SEriAL
SEL
bAUd
Baud Rate
dAtA
Data Bit
*
PAritY
Parity Bit
*
Addr
Meter
Address
Abbr
Abbreviated
Printing
*
Prnt OPt
Options
Pro
Module 5 is the programming module for the Serial Communications
Parameters. The only paramters of concern when utilizing the CUB5USB programming option card to communicate with Crimson 2 programming software is the Baud Rate and Meter Address. The Parameters are only accessible when an optional CUB5USB, RS232 or RS485 serial communications card is installed in the meter.
Indicates Program Mode Alternating Display.
Parameter
Selection/Value
Factory Settings are shown.
METER ADDRESS
Addr
00
0 to 99
Enter the serial node address. With a single unit, an address is not needed and a value of zero can be used (RS232 applications). Otherwise, with multiple bussed units, a unique address number must be assigned to each meter. The node address applies specifically to RS485 applications.
BAUD RATE
bAUd
9600
300 1200
600 2400
4800
9600
19200
38400
Set the baud rate to match that of other serial communications equipment.
Normally, the baud rate is set to the highest value that all of the serial communications equipment is capable of transmitting and receiving.
ABBREVIATED PRINTING *
Abbr
NO YES
NO
This parameter determines the formatting of data transmitted from the meter in response to a Transmit Value command or a Block Print Request. Select parameter data. Select
YES
NO for a full print transmission, consisting of the meter address, mnemonics, and
for abbreviated print transmissions, consisting of the parameter data only. This setting is applied to all the parameters selected in the
PRINT OPTIONS. (Note: If the meter address is 0, the address will not be sent during a full transmission.)
DATA BIT *
dAtA
7-bit
7-bit 8-bit
Select either 7- or 8-bit data word length. Set the word length to match the other serial communications equipment on the serial link.
PARITY BIT*
PAr
Odd
NO Odd EVEN
This parameter only appears when the Data Bit parameter is set to a 7-bit data word length. Set the parity bit to match that of the other serial equipment on the serial link. The meter ignores parity when receiving data and sets the parity bit for outgoing data. If parity is set to to force the frame size to 10 bits.
NO , an additional stop bit is used
PRINT OPTIONS *
OPt
NO
NO YES
This parameter selects the meter values transmitted in response to a Print
Request. A print request is also referred to as a block print because more than one parameter can be sent to a printer or computer as a block.
Selecting
YES displays a sublist for choosing the meter parameters to appear in the print block. All active parameters entered as transmitted during a block print. Parameters entered as
The “Print All” ( P-ALL
YES in the sublist will be
NO will not be sent.
) option selects all meter values for transmitting ( without having to individually select each parameter in the sublist.
YES ),
Note: Inactive parameters will not be sent regardless of the print option setting. For example, the Setpoint value(s) will not be sent unless an optional setpoint card is installed in the meter.
* - Disregard these parameters when configuring unit to upload or download wth
Crimson software.
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Softwareweg 9
NL - 3821 BN Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
2
Red Lion Controls
India
201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30
Gurgaon-122002 Haryana, India
Tel +91 984 487 0503
Red Lion Controls
China
Unit 302, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113 3688
Fax +86 21 6113 3683

Public link updated