Red Lion CUB4L is a miniature electronic counter with a large, easy-to-read display and a variety of features that make it ideal for a wide range of applications. It offers count speeds up to 5 kHz, internal lithium battery providing up to 6 years of uninterrupted operation, NEMA 4X/IP65 sealed front bezel, and both front panel and remote reset options. The CUB4L is also versatile, with the ability to handle both SNK and SRC input modes, making it compatible with a variety of sensors and devices.
Advertisement
Advertisement
Bulletin No. CUB4L-C
Drawing No. LP0793
Released 06/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839 www.redlion.net
MODEL CUB4L & CUB4L8 - MINIATURE ELECTRONIC COUNTERS
LCD, POSITIVE REFLECTIVE OR NEGATIVE TRANSMISSIVE
WITH YELLOW/GREEN OR RED LED BACKLIGHTING
INTERNAL LITHIUM BATTERY PROVIDES UP TO 6 YEARS OF
UNINTERRUPTED OPERATION
NEMA 4X/IP65 SEALED FRONT BEZEL
FRONT PANEL RESET, REMOTE RESET, OR BOTH
COUNT SPEEDS UP TO 5 KHz
WIRE CONNECTION MADE VIA SCREW CLAMP TYPE
TERMINALS
DESCRIPTION
The CUB4 offers a large display in a miniature package with a choice of three displays; reflective, red backlight or green backlight.
The backlight versions require power from an external 9–28 VDC supply. The optional power supply (MLPS) is designed to be attached directly to the rear of the CUB4 and is powered from an 85–250 VAC source.
The CUB4 series has a lightweight, high impact plastic case with a clear viewing window. The sealed front panel with the silicone rubber reset button meets NEMA 4X/IP65 specifications for wash-down and/or dusty environments, when properly installed.
ORDERING INFORMATION
MODEL NO. DESCRIPTION
Counter Positive Image Reflective
CUB4L
(6-digit)
Counter w/Yel-Grn Backlighting
Counter w/Red Backlighting
CUB4L8
(8-digit)
MLPS
Counter Positive Image Reflective
Counter w/Yel-Grn Backlighting
Counter w/Red Backlighting
+12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out
+24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out
PART NUMBERS
CUB4L000
CUB4L010
CUB4L020
CUB4L800
CUB4L810
CUB4L820
MLPS1000
MLPS2000
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
CAUTION: Risk of Danger.
Read complete instructions prior to installation and operation of the unit.
SPECIFICATIONS
1. DISPLAY:
CUB4L: 6-Digit, LCD, 0.48" (12.2 mm) high digits.
CUB4L8: 8-Digit, LCD, 0.46" (11.7 mm) high digits.
2. POWER SOURCE: Internal 3.6 V lithium battery will provide up to 6 years of continuous operation (high speed counting and extreme temperatures will decrease battery life).
3. BACKLIGHT POWER REQUIREMENTS: 9 to 28 VDC, 30 mA typical,
50 mA max. Above 26 VDC, derate operating temperature to 50°C.
Must use an RLC model MLPS or an NEC Class 2 or Limited Power Source
(LPS) rated power supply.
4. COUNT INPUT:
SNK mode (DIP switch 1 off, internal pull-up to battery)
IN
Low Max = 0.45 VDC
Max = 3.6 VDC I
V
IN
IN
High Min = 1.25 VDC; V
Max = 5 µA; V
Count Speed: (count on negative edge)
High freq mode (DIP switch 2 off): max 5 kHz @ 50% duty cycle
Low freq mode (DIP switch 2 on): max 50 Hz @ 50% duty cycle
SRC mode (DIP switch 1 on, internal 20 kW pull-down to common)
V
IN
High Min = 1.25 VDC; V
Max = 5 mA; V
IN
Low Max = 0.45 VDC
IN
Max = 28 VDC I
IN
Count Speed: (count on negative edge)
High freq mode (DIP switch 2 off): max 5 kHz @ 50% duty cycle
Low freq mode (DIP switch 2 on): max 50 Hz @ 50% duty cycle
5. RESET INPUT:
V
IN
I
IN
Low Max = 1.5 VDC (internal pull-up to battery)
Max = 20 µA
5 msec min (active low for count reset to zero)
6. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 60°C (above 50°C, derate backlight operating voltage to 26 VDC max.).
Storage Temperature: -30 to 85°C
Operating and Storage Humidity: 85% max. (non-condensing) from 0°C to 50°C.
Vibration to IEC 68-2-6: 5 to 500 Hz, 5 g.
Shock to IEC 68-2-27: Operational 30 g.
Altitude: Up to 2000 meters
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
0.13 (3.2)
PANEL CUT-OUT
2.68
+.025
-.000
(68 )
1.54 (39.1) 1.29 (32.8)
1.30
+.024
-.000
(33 )
2.95 (74.9) 0.15 (3.8) 1.36 (34.5)
1
7. CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class B
IEC/EN 61010-1
RoHS Compliant
UL Recognized Component: File #E179259
Type 4X Indoor Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
Refer to EMC Installation Guidelines section of the bulletin for additional information.
8. CONSTRUCTION:
This unit is rated for NEMA 4X/IP65 indoor use. Installation Category I,
Pollution Degree 2
9. WEIGHT: 3 oz. (85 grams)
EMC INSTALLATION GUIDELINES
Although Red Lion Controls Products are designed with a high degree of immunity to Electromagnetic Interference (EMI), proper installation and wiring methods must be followed to ensure compatibility in each application. The type of the electrical noise, source or coupling method into a unit may be different for various installations. Cable length, routing, and shield termination are very important and can mean the difference between a successful or troublesome installation. Listed are some EMI guidelines for a successful installation in an industrial environment.
1. A unit should be mounted in a metal enclosure, which is properly connected to protective earth.
2. Use shielded cables for all Signal and Control inputs. The shield connection should be made as short as possible. The connection point for the shield depends somewhat upon the application. Listed below are the recommended methods of connecting the shield, in order of their effectiveness.
a. Connect the shield to earth ground (protective earth) at one end where the unit is mounted.
b. Connect the shield to earth ground at both ends of the cable, usually when the noise source frequency is over 1 MHz.
3. Never run Signal or Control cables in the same conduit or raceway with AC power lines, conductors, feeding motors, solenoids, SCR controls, and heaters, etc. The cables should be run through metal conduit that is properly grounded. This is especially useful in applications where cable runs are long and portable two-way radios are used in close proximity or if the installation is near a commercial radio transmitter. Also, Signal or Control cables within an enclosure should be routed as far away as possible from contactors, control relays, transformers, and other noisy components.
4. Long cable runs are more susceptible to EMI pickup than short cable runs.
5. In extremely high EMI environments, the use of external EMI suppression devices such as Ferrite Suppression Cores for signal and control cables is effective. The following EMI suppression devices (or equivalent) are recommended:
Fair-Rite part number 0443167251 (RLC part number FCOR0000)
Line Filters for input power cables:
Schaffner # FN2010-1/07 (Red Lion Controls # LFIL0000)
6. To protect relay contacts that control inductive loads and to minimize radiated and conducted noise (EMI), some type of contact protection network is normally installed across the load, the contacts or both. The most effective location is across the load.
a. Using a snubber, which is a resistor-capacitor (RC) network or metal oxide varistor (MOV) across an AC inductive load is very effective at reducing
EMI and increasing relay contact life.
b. If a DC inductive load (such as a DC relay coil) is controlled by a transistor switch, care must be taken not to exceed the breakdown voltage of the transistor when the load is switched. One of the most effective ways is to place a diode across the inductive load. Most RLC products with solid state outputs have internal zener diode protection. However external diode protection at the load is always a good design practice to limit EMI.
Although the use of a snubber or varistor could be used.
RLC part numbers: Snubber: SNUB0000
Varistor: ILS11500 or ILS23000
7. Care should be taken when connecting input and output devices to the instrument. When a separate input and output common is provided, they should not be mixed. Therefore a sensor common should NOT be connected to an output common. This would cause EMI on the sensitive input common, which could affect the instrument’s operation.
Visit RLC’s web site at http://www.redlion.net/Support/InstallationConsiderations.
html for more information on EMI guidelines, Safety and CE issues as they relate to Red Lion Controls products.
INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the unit near devices that generate excessive heat should be avoided.
The bezel should be cleaned only with a soft cloth and neutral soap product.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the keypad of the unit.
Installation
The CUB4 series of products meet NEMA 4X/IP65 requirements for indoor use, when properly installed. The units are intended to be mounted into an enclosed panel. The viewing window and reset button are factory sealed for a washdown environment. A sponge rubber gasket and mounting clip are provided for sealing the unit in the panel cut-out.
The following procedure assures proper installation:
1. Cut panel opening to specified dimensions. Remove burrs and clean around panel opening.
2. Carefully remove the center section of the panel gasket and discard.
Slide gasket over rear of the unit to the back of the bezel.
3. Assemble nut fastener first and then mounting screw onto both sides of mounting clip. Tip of screw should not project from hole in mounting clip.
4. Install CUB4 unit through the panel cut-out until front bezel flange contacts the panel-mounted gasket.
5. Slide the mounting clip over the rear of the unit until the mounting clip is against the back of the panel. The mounting clip has latching features which engage into mating features on the CUB4 housing.
Note: It is necessary to hold the unit in place when sliding mounting clip into position.
MOUNTING
SCREW
NUT
FASTENER
LATCHING
FEATURE
LATCHING
FEATURE
6. Alternately tighten each screw to ensure uniform gasket pressure. Visually inspect the front panel gasket. The gasket should be compressed about 75 to
80% of its original thickness. (Recommended torque is 28 to 36 in-oz.) If not, gradually turn mounting screws to further compress gasket.
7. If gasket is not adequately compressed, and mounting screws can no longer be turned, loosen mounting screws and check that mounting clip is latched as close as possible to panel.
Repeat procedure for tightening mounting screws.
2
WIRING CONNECTIONS
The electrical connections are made via rear screw-clamp terminals located on the back of the unit. When wiring the unit, use the label to identify the wire position with the proper function. All conductors should meet voltage and current ratings for each terminal. Also cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that power supplied to the unit (AC or DC) be protected by a fuse or circuit breaker. Strip the wire, leaving approximately 1/4" bare wire exposed (stranded
wires should be tinned with solder). Insert the wire into the screw-clamp terminal and tighten down the screw until the wire is clamped tightly. Each terminal can accept up to two #14 AWG wires.
Backlight Wiring
Optional backlight versions of the CUB4 require an external 9-28 VDC power supply. The external supply is connected between the V+ and Common terminals.
3 RESET
1 COM
!
M1406_
CUB4
COUNT 4
9-28 VDC 2
_
Backlight Power Supply
(MLPS)
+
Warning: Lithium battery may explode if incinerated.
COUNT INPUT WIRING
Current Sinking Output
ON
1 2
*
3
Logic Output
3 Reset
1
Com
CNT
4
9-28VDC
2
Current Sourcing Output
+V
ON
1 2
*
3
3 Reset
1
Com
Switch/Contact Sinking Output
CNT
4
9-28VDC 2
ON
1 2
*
3 3
1
Reset
Com
Switch/Contact Sourcing Output
+V
ON
1 2
*
3
3 Reset
1
Com
CNT
4
9-28VDC 2
CNT
4
9-28VDC 2
ON
1 2
*
3 3 Reset
1
Com
CNT
4
9-28VDC 2
Switch position is application dependent.
3
SETTING THE DIP SWITCHES
The switches must be positioned appropriately prior to wiring. Placing the key disable/enable DIP switch in the off position disables the front panel key.
RESETTING THE DISPLAY
The display may be reset to zero via the front RST key, the remote reset input or both. The front RST key must be enabled for front panel reset by setting DIP switch # 3 ON. The remote reset is activated via an external momentary contact closure between the reset input and the common.
ON
3 RESET
1 COM
!
M1406_
CUB4
COUNT 4
9-28 VDC 2
YORK, PA.
MADE IN U.S.A.
CUB4L
1 2 3
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate company numbers listed.
3 RESET
1 COM
!
M1406_
CUB4
COUNT 4
9-28 VDC 2
YORK, PA.
MADE IN U.S.A.
CUB4L8
1
2
3
SNK
HI FREQ
KEY DIS
SRC
LO FREQ
KEY EN
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Softwareweg 9
NL - 3821 BN Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls
India
201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30
Gurgaon-122002 Haryana, India
Tel +91 984 487 0503
Red Lion Controls
China
Unit 302, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113 3688
Fax +86 21 6113 3683

Public link updated
The public link to your chat has been updated.
Advertisement