Table of Contents
1. Communication Parameter ............................................................ 3
2. Pin Configuration ................................................................................. 3
3. Communication Data Format ........................................................ 3
4. General Function ................................................................................. 5
5. Picture/Sound ...................................................................................... 10
6. Size/Shift .................................................................................................. 12
7. Status Enquiry ..................................................................................... 14
8. User Reset ............................................................................................... 16
FWD-50PX1
1
1. Communication Parameter
3. Communication Data Format
(a) Control (Host → Request of Write to Display)
Communication system
RS-232C
Synchronous system
Asynchronous communication
No.
Item
Value
Baud rate
9600 bps
1
Header
0x8C: Control
Character length
8 bit
2
Category
0xXX
Parity
None
3
Function
0xXX
Start bit
1 bit
4
Data1 (Length)
0xXX
Stop bit
1 bit
5
Data2 (Data1)
0xXX
Flow control
None
:
:
0xXX
:
:
0xXX
X
DataX
0xXX
X+1 Check Sum
0xXX
2. Pin Configuration
Display side (D-sub 9-pin)
Host side (D-sub 9-pin)
* Check Sum: If the value of a sum total of 1 to X exceeds 255 (1 byte), the
data of 1 lower byte is effective.
(b) Enquiry (Host → Request of Read to Display)
FWD-50PX1
5
4
9
3
8
2
7
1
6
_ External view _
Pin No.
1
2
3
4
5
6
7
8
9
FWD-50PX1
Signal
NC
RD
TD
NC
GND
NC
NC
NC
NC
Personal computer
5
4
9
3
8
2
7
1
6
_ External view _
Pin No.
1
2
3
4
5
6
7
8
9
No.
Item
Value
1
Header
0x83: Enquiry
2
Category
0xXX
3
Function
0xXX
4
Data1
0xFF
5
Data2
0xFF
6
Check Sum
0xXX
* Check Sum: If the value of a sum total of 1 to 5 exceeds 255 (1 byte), the
data of 1 lower byte is effective.
Signal
NC
RD
TD
NC
GND
NC
NC
NC
NC
3
(c) Answer (Display → Response to Host)
1 Answer at the time of Control request
3 Answer at the time of Enquiry request
(Abnormal completion)
No.
Item
Value
No.
Item
Value
1
Header
0x70: Answer
1
Header
0x70: Answer
2
Answer*
0x00: Completed (Normal completion)
2
Answer
0x03: Command Canceled
(Abnormal completion)
3
Check Sum
0xXX
0x01: Limit Over
(Abnormal completion: Over upper limit)
3
Check Sum
0x02: Limit Under
(Abnormal completion: Under lower limit)
* 0x03: Command Canceled
0x03: Command Canceled
(Abnormal completion)
* Check Sum:
0xXX
* 0x00: Completed
0x01: Limit Over
0x02: Limit Under
0x03: Command Canceled
* Check Sum:
Packet is correctly received and process is
also correctly completed.
Packet is correctly received, but the data
value is over the upper limit.
Packet is correctly received, but the data
value is under the lower limit.
Packet is correctly received, but the data
value is not correct or the request cannot be
accepted in the current host state.
4 Error Answer
No.
Item
Value
1
Header
0xE0: Answer
2
Answer*
0x00: No Function Error
0x01: Check Sum Error
0x02: Data Number Error
If the value of a sum total of 1 and 2
exceeds 255 (1 byte), the data of 1 lower
byte is effective.
2 Answer at the time of Enquiry request
(Normal completion)
0x06: Mode Error
0x07: Time Out
3
Check Sum
0xXX
* 0x00: No Function Error
No.
Item
Value
0x01: Check Sum Error
1
Header
0x70: Answer
0x02: Data Number Error
2
Answer
0x00: Completed
3
Return Data Size
0xXX
4
Return Data1
0xXX
:
:
0xXX
:
:
0xXX
X
Return DataX
0xXX
X+1 Check Sum
Packet is correctly received, but the
data value is not correct or the request
cannot be accepted in the current host state.
If the value of a sum total of 1 to 2 exceeds
255 (1 byte), the data of 1 lower byte is
effective.
0x06: Mode Error
0x07: Time Out
Packet header, category and function code
are not included in this protocol.
Check sum value of received packet is not
correct.
Data value in “Data Number” area of the
received packet is different from the data
number of the function.
Monitor is already in the service mode by the
operation of remote commander. (IR remote
commander precedes the serial remote
commander.)
Packet communication is interrupted due to an
error and does not return to the normal
communication state within 2 seconds.
0xXX
* 0x00:
Completed packet is correctly received and process is also
correctly completed.
* Return Data returns the read value.
* Check Sum: If the value of a sum total of 1 to X exceeds 255 (1 byte), the
data of 1 lower byte is effective.
4
FWD-50PX1
4. General Function
(a) Mode control
Syntax
Header
Category
Function
Data1
Data2
Check Sum
Control
0x8C
0x00
Code Table (1-a) [a]
0x02
Code Table (1-a) [b]
0xXX
Enquiry
0x83
0xFF
0xFF
0xXX
Answer
Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x01
0x71
Limit Over
0x70
0x02
0x72
Limit Under
0x70
0x03
0x73
Command Canceled
Answer
Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x70
0x00
0x02
Code Table (1-a) [b]
0xXX
Completed
Code Table (1-a)
[a]Function
0x00
0x01
0x02
0x03
0x04
0x05
FWD-50PX1
Power
Input Select
Force Status Display
Audio Mute
Auto Status Display
Closed Caption
[b]Range/Switch Code
0x00
OFF
0x01
ON
0x08
INPUT1 RGB
0x09
INPUT1 COMPONENT
0x0A
INPUT2 RGB
0x0B
INPUT2 COMPONENT
0x0C
OPTION VIDEO
0x0D
OPTION S VIDEO
0x0E
OPTION RGB
0x0F
OPTION COMPONENT
0x00
ON1 (Signal)
0x01
ON2 (Clock)*
0x02
OFF
0x00
OFF
0x01
ON
0x00
ON
0x01
OFF
0x00
OFF
0x01
CC1
0x02
CC2
0x03
CC3
0x04
CC4
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Enable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Enable
Enable
Yes
Yes
Disable
Enable
5
Code Table (1-a)
[a]Function
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
6
Color System
Auto Color System
Power Saving
ON/OFF timer
Timer Repeat
Picture Inversion
Picture Orbit
Orbit Range
Orbit Cycle
Language
[b]Range/Switch Code
0x00
Auto
0x01
NTSC
0x02
NTSC4.43
0x03
PAL
0x04
SECAM
0x05
PAL-M
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
0x06
PAL-N
0x07
PAL60
0x00
NTSC/PAL/SECAM/NTSC4.43 Yes
0x01
NTSC/PAL-M/PAL-N
0x00
OFF
0x01
5min.
0x02
10min.
0x00
OFF timer
0x01
ON timer
0x02
ON/OFF timer
0x03
OFF
0x00
OFF
0x01
ON
0x00
OFF
0x01
Auto
0x02
ON
0x00
OFF
0x01
ON
0x00
Small
0x01
Middle
0x02
Large
0x00
10sec.
0x01
30sec.
0x02
1min.
0x03
5min.
0x00
Japanese
0x01
English
0x02
Deutsch
0x03
Français
0x04
Español
0x05
Italiano
0x10
Index Number
0x01-0xFF
Yes
Yes
Disable
Enable
0x11
Remote Mode
0x00
ON
Yes
Yes
Disable
Enable
0x01
OFF
FWD-50PX1
Code Table (1-a)
[a]Function
0x12
0x13
0x14
0x16
0x17
Remote Only
Energy Saving
Speaker Out
HD Mode
RGB Mode
0x18
Sync Mode
0x19
Menu Key
0x1B
0x40
0x41
[b]Range/Switch Code
Clock Display
All White
BackGround
0x00
OFF
0x01
ON
0x00
Standard
0x01
Reduce
0x00
ON Yes
0x01
OFF
0x00
1080i
0x01
1035i
0x00
DTV
0x01
PC
0x00
H/Comp
0x01
Video
0x00
ON/OFF
0x01
RETURN
0x00
OFF
0x01
ON
0x00
OFF
0x01
ON
0x00
Gray
0x01
Dark Gray
0x02
Black
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
* This is enabled when Clock Display is set to ON. When Display is set to OFF, Status Display is also set to OFF.
IP Address
Syntax
Header
Category Function
Data1
Data2
Data3
Data4
Data5
Check Sum
Enquiry
0x83
0x00
0x42
0x05
Address 0
0x00-0xFF
Address 1
0x00-0xFF
Address 2
0x00-0xFF
Address 3
0x00-0xFF
0xXX
Answer Header
Answer
Check Sum
Enquiry
0x70
0x00
0x70
Completed
0x70
0x03
0x73
Command Canceled
Example of IP Address setting
192. 128. 14. 1 → 192 (0xC0)
Address 0
128 (0x80)
Address 1
14 (0x0E)
Address 2
1 (0x01)
Address 3
* IP Address command can be carried out even in the standby state.
FWD-50PX1
7
(b) Color matrix
Syntax
Header
Category Function
Data1
Data2
Data3
Control
0x8C
0x00
0x03
Code Table (1-c)
Code Table (1-b) [b] 0xXX
Enquiry
0x83
Code Table (1-c)
0xFF
0xFF
Code Table (1-b) [a]
Check Sum
0xXX
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x03
0x73
Command Canceled
Answer Header
Answer
Return to Data Size
Return Data1
Return Data2
Enquiry
0x00
0x03
Code Table (1-c)
Code Table (1-b) [b] 0xXX
Completed
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
0x70
Check Sum
Code Table (1-b)
[a]Function
0x1D
[b]Range/Switch code
Color Matrix
0x00
YCbCr
0x01
YPbPr
Code Table (1-c)
Format Select
8
0x00
480p
0x01
1080i
0x02
720p
FWD-50PX1
(c) Time control
Syntax
Header
Category Function
Data1
Data2
Data3
Check Sum
Control
0x8C
0x00
0x03
Hour: 0x00-0x17
Minute: 0x00-0x3B
0xXX
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x00
Code Table (1-d) [a]
0xFF
0xFF
0xXX
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x01
0x71
Limit Over
Code Table (1-d) [a]
0x70
0x02
0x72
Limit Under
0x70
0x03
0x73
Command Canceled
Answer Header
Answer
Return to Data Size
Return Data1
Return Data2
Check Sum
Enquiry
0x00
0x03
Hour: 0x00-0x17
Minute: 0x00-0x3B
0xXX
Completed
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
0x70
Code Table (1-d)
[a]Function
[b]Range/Switch code
ON/OFF Timer
0x1E
Power ON Time
0x1F
Power OFF Time
Picture Inversion
0x20
Invert Start Time
0x21
Time Set
0x22
FWD-50PX1
Yes
Yes
Disable
Enable
Invert End Time
Yes
Yes
Disable
Enable
Time Set
Yes
Yes
Disable
Enable
9
5. Picture/Sound
(a) Picture/Sound
Syntax
Header
Category Function
Data1
Data2
Check Sum
Control
0x8C
0x10
0x02
Code Table (2-a) [b]
0xXX
Enquiry
0x83
0xFF
0xFF
0xXX
Code Table (2-a) [a]
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x01
0x71
Limit Over
0x70
0x02
0x72
Limit Under
0x70
0x03
0x73
Command Canceled
Answer Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x00
0x02
Code Table (2-a) [b]
0xXX
0x70
Completed
Code Table (2-a)
[a]Function
[b]Range/Switch Code
Command
Control
Enquiry
Standby
Power On
0x00
Contrast
0x00-0xFF
Yes
Yes
Disable
Enable
0x01
Brightness
0x00-0xFF
Yes
Yes
Disable
Enable
0x02
Chroma
0x00-0xFF
Yes
Yes
Disable
Enable
0x03
Phase
0x00-0xFF
Yes
Yes
Disable
Enable
0x04
Color Temp
0x00
Yes
Yes
Disable
Enable
High
0x01
Mid
0x02
Low
0x03
User1
0x04
User2
0x05
User3
0x09
Sharpness
0x00-0xFF
0x0A
NR
0x00
OFF
0x01
Low
0x02
Mid
0x03
High
0x0B
0x0C
0x0D
0x0E
10
Cinema Drive
Dynamic Picture
Color Correct
Gamma Correct
0x00
Auto
0x01
OFF
0x00
ON
0x01
OFF
0x02
ON
0x03
OFF
0x00
High
0x01
Mid
0x02
Low
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
FWD-50PX1
Code Table (2-a)
[a]Function
0x0F
0x10
[b]Range/Switch Code
Window Mode
Picture Mode
0x00
OFF
0x01
Small
0x02
Large
0x00
Standard
0x01
Dynamic
0x02
User1
0x03
User2
0x04
User3
0x00-0x64
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Enable
Enable
0x30
Volume
0x31
Treble
0x00-0x64
Yes
Yes
Disable
Enable
0x32
Bass
0x00-0x64
Yes
Yes
Disable
Enable
0x33
Balance
0x00-0x64
Yes
Yes
Disable
Enable
0x34
Surround
0x00
OFF
Yes
Yes
Disable
Enable
0x01
Hall
0x02
Simulate
(b) Color temperature
Syntax
Header
Category Function
Data1
Data2
Data3
Check Sum
Control
0x8C
0x10
0x03
Code Table (2-c)
Code Table (2-b) [b]
0xXX
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x10
Code Table (2-b) [a]
0xFF
0xFF
0xXX
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x03
0x73
Command Canceled
Answer Header
Answer
Return to Data Size
Return Data1
Return Data2
Check Sum
Enquiry
0x00
0x03
Code Table (2-c)
Code Table (2-b) [b]
0xXX
0x70
Code Table (2-b) [a]
Completed
Code Table (2-b)
[a]Function
[b]Range/Switch code
0x00-0xFF
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
0x05
Red Gain
0x06
Green Gain
0x00-0xFF
Yes
Yes
Disable
Enable
0x07
Blue Gain
0x00-0xFF
Yes
Yes
Disable
Enable
Code Table (2-c)
Format Select
0x03
User1
0x04
User2
0x05
User3
FWD-50PX1
11
6. Size/Shift
(a) 16 bit register
Syntax
Header
Category Function
Data1
Data2
Data3
Check Sum
Control
0x8C
0x20
0x03
Code Table (3-a) [b]
Code Table (3-a) [b]
0xXX
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x20
Code Table (3-a) [a]
0xFF
0xFF
0xXX
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x01
0x71
Limit Over
0x70
0x02
0x72
Limit Under
Answer Header
Answer
Return to Data Size
Return Data1
Return Data2
Check Sum
Enquiry
0x00
0x03
Code Table (3-a) [b]
Code Table (3-a) [b]
0xXX
0x70
Code Table (3-a) [a]
Completed
Code Table (3-a)
[a]Function
0x0A
[b]Range/Switch code
H Total Pixel
0x0190-0x09C4
Command
Control
Enquiry
Standby
Power On
Yes
Yes
Disable
Enable
(b) 8 bit register
Syntax
Header
Category Function
Data1
Data2
Check Sum
Control
0x8C
0x20
Code Table (3-b) [a]
0x02
Code Table (3-b) [b]
0xXX
Enquiry
0x83
0xFF
0xFF
0xXX
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x01
0x71
Limit Over
0x70
0x02
0x72
Limit Under
0x70
0x03
0x73
Command Canceled
Answer Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x00
0x02
Code Table (3-b) [b]
0xXX
12
0x70
Completed
FWD-50PX1
Code Table (3-b)
[a]Function
[b]Range/Switch code
Command
Control
Enquiry
Standby
Power On
0x00
H Size
0x00-0xFF
Yes
Yes
Disable
Enable
0x01
H Shift
0x00-0xFF
Yes
Yes
Disable
Enable
0x02
V Size
0x00-0xFF
Yes
Yes
Disable
Enable
0x03
V Shift
0x00-0xFF
Yes
Yes
Disable
Enable
0x04
Zoom Mode
0x00
Wide Zoom
Yes
Yes
Disable
Enable
0x01
Zoom
Yes
Yes
Disable
Enable
Yes
No
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
Yes
Yes
Disable
Enable
0x05
Zoom Size
0x02
Full
0x03
Sub Title
0x04
Normal
0x00
Standard
0x01
x2
0x02
x3
0x03
x4
Execute
0x06
Auto Pixel Adjust
0xFF
0x07
Dot Phase
0x00-0x3F
0x08
Auto Wide
0x00
OFF
0x01
Auto
0x09
4:3 Mode
0x00
Normal
0x01
Wide Zoom
FWD-50PX1
13
7. Status Enquiry
(a) Model name enquiry
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x00
0xFF
0xFF
0xB1
Answer Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x00
0x02
Code Table (4-a)
0xXX
Completed
0x70
Code Table (4-a)
Format Select
0x07
FWD-50PX1
(b) Serial number enquiry
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x01
0xFF
0xFF
0xB2
Answer Header
Answer
Return to
Data Size
Return Data1 Return Data2
Return Data3 Return Data4 Check Sum
Enquiry
0x00
0x05
Upper 8bit
Data
Middle Lower
Data
0x70
Middle Upper
Data
Lower 8bit
Data
0xXX
Completed
Return Data1-Data4: 0x001E8480-0x002DC6BF (2,000,000-2,999,999)
(c) Operating time enquiry
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x02
0xFF
0xFF
0xB3
Answer Header
Answer
Return to
Data Size
Return Data1 Return Data2
Return Data3 Return Data4 Check Sum
Enquiry
0x00
0x05
Upper 8bit
Data
Middle Lower
Data
0x70
Middle Upper
Data
Lower 8bit
Data
0xXX
Completed
Return Data1-Data4: 0x00000000-0xD693A3FF (0sec._3,599,999,999sec.)
14
FWD-50PX1
(d) Software version enquiry (Main CPU)
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x03
0xFF
0xFF
0xB4
Answer Header
Answer
Return to Data Size
Return Data1
Return Data2
Enquiry
0x00
0x03
Upper 8bit Data
Lower 8bit Data
Completed
0x70
Return Data1-Data2: 0x0000-0xFFFF
(e) H/V frequency enquiry
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0xFF
0xFF
0xXX
Code Table (4-b)
Answer Header
Answer
Return to
Data Size
Return Data1 Return Data2
Return Data3 Return Data4 Check Sum
Enquiry
0x00
0x05
Upper 8bit
Data
MiddleLower
Data
0x70
MiddleUpper
Data
Lower 8bit
Data
0xXX
Completed
Return Data1-Data4: 0x0000-0xFFFF
Code Table (4-b)
Function
0x04
H Frequency
0x05
V Frequency
(f) Sync polarity enquiry
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x06
0xFF
0xFF
0xB7
Answer Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x00
0x02
Code Table (4-c)
0xXX
Answer Header
Answer
Check Sum
Enquiry
0x03
0x73
0x70
0x70
Completed
Command Canceled
Code Table (4-c)
Sync Polarity
0x00
H: Nega/V: Nega
0x01
H: Nega/V: Posi
0x02
H: Posi/V: Nega
0x03
H: Posi/V: Posi
0x04
SonG
0x05
No H/V Sync
FWD-50PX1
15
(g) 8 bit register enquiry
Syntax
Header
Category Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
Code Table(4-d)
0xFF
0xFF
0xXX
Answer Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x00
0x02
Code Table (4-d)
0xXX
Completed
0x70
Code Table (4-d)
Function
Return Data
Unit
0x07
Digital 3.3 V
0x00-0xFF
0x08
Analog 6 V
0x00-0xFF
0x09
Digital 5 V
0x00-0xFF
/10 V
0x0A
Temp1
0x00-0xFF
Degree
0x0B
Temp2
0x00-0xFF
Degree
0x0C
Temp3
0x00-0xFF
Degree
0x0D
Temp (P/S)
0x00-0xFF
0x0E
Fan Status
0=OK, 1=NG
8. User Reset
Syntax
Header
Category Function
Data1
Data2
Check Sum
Control
0x8C
0x50
Code Table (5)
0x02
0xFF
0xXX
Answer Header
Answer
Check Sum
Control
0x70
0x00
0x70
Completed
0x70
0x03
0x73
Command Canceled
Code Table (5)
Function
Range/Switch code
Command
Control
Enquiry
Standby
Power On
0x00
Picture Reset
Yes
No
Disable
Enable
0x01
Audio Reset
Yes
No
Disable
Enable
0x02
Size Reset
Yes
No
Disable
Enable
0x03
PLL Reset
Yes
No
Disable
Enable
16
FWD-50PX1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement