Below you will find brief information for washer SUPER 20 CL8761, washer SUPER 20 CL8763, washer SUPER 20 CL8771. This manual will provide you with the steps needed to properly install and maintain your washer. This washer is a powerful machine that can handle even the toughest stains, and with the help of these instructions, you can keep it running smoothly for years to come.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
13
INSTALLATION and MAINTENANCE INSTRUCTIONS (SPEED QUEEN. — SUPER 20 WASHER - EXTRACTOR p MODELS N CL8761, CL8763, CL8771& CL8773 \_ SPEED QUEEN à Hipon. Wisconsin 549771 MINTE mm 9 PART NO. 81216R8 Table of Contents ROUGHING-IN DIMENSIONS | | SPECIFICATIONS ................ PA naar 3 SECTIONI INSTALLATION 1. Facilities Required ............ —.eeeoc0oreaoreac ona onanonraronorerc 4 2. Installation Materials ..........ooe._eeexrecoredacoreaaderaceoonnoo, 4 3. To Install On Existing Concrete Floor .................. i. 5 4. To Install On Concrete Slab................. 0... ii, 6 S. Installing Washer ..........._ eee. .00r0ede dao nececenaoronna aora, 8 6. Water Inlet Hose Connections .................. esrredcereaarorareo 9 7. Electrical Service ......... nadadencoonoenecenreraoecr.reaeenea roce 9 8. Grounding 122001000000 aa a a a Le ee a a a de a de de aa aa aa aa aa 9 9. Drain Hose - Gravity Drain Models. ................. e. LL 10 10. Drain Hose — Pump Models. .......... cco. 10 11. Drive Belt ........... ........eeea00aearersececaooooaecaa)roereoo 10 SECTION II MAINTENANCE 12. Daily Maintenance ‚eK LL H 13. Weekly Maintenance .........eoéoexexosserecarreroorerencrerervdoednercaoo 11 14. Periodic Maintenance ...........c. iinet eee eae, 12 Roughing -in Dimensions 12-1/8” —-«——e Ent nil Bios. 19-3/16” SPEED QUEEN. “a 47" | N чз”! I =—16-3/4"— IN — ль. : a | т | \ В НН of ~ MOUNTING BOLT LOCATIONS = «==> === [ ZN OE — В 3 — — | — | ' — — | y | 27-3/16" + = = = - | a XT —e << | | Î — < с 13-9/16" (GRAVITY (PUMP . || | DRAIN MODELS) MODELS) ne el tl Е ЕЕ : LLL НАД | 30" — FRONT OF WASHER BASE ное Cpecfimtiona Cabinet Finish: Hi-baked acrylic enamel rear and side panels; stainless steel dis- penser door, front panel and air intake grille, Porcelain cabinet top. Height: 46-1/2 inches. — Width: 30 inches. I Depth: = тт нашел CT 1 28 0e 0 a Em. wm + сн но - 4 Electrical Rating: Drive Motor: Blower Motor: [ — .. Er A A a, A Mr ee 30-1/4 inches, — A e Ps E Ad a 120/240 volt, 60 Hertz. Single phase, three wire, 10.5 amps. Also available for 120/208 volt operation. Internal overload protected. Wound for 230 volt, 60 Hertz opera- tion at 3450 and 400 R.P.M. Also available for 208 voit operation. Lifetime lubricated. Wound for 115 volt, 60 Hertz operation at 3000 R.P.M. Pump Motor: | Models CL8763 & CL8773 Wound for 115 volt, 60 Hertz operation at 3000 R.P.M. Clothes Cylinder: Stainless steel. Cycle Timer: Reversing Timer: Water Mixing Valve: — Weight: 30 minutes — complete cycle. Reverses drive motor every 30 seconds in tumble portion of cycle. 3.8 gpm water flow rate. 418 Ibs. (approximate). +r aa Aa Installation section : ~—— IMPORTANT WARRANTY IS VOID unless washer is installed according to instructions in ) this manual. Compliance with minimum specifications and requirements out- lined in this manual and local building codes is a MUST! Because of varied requirements, local plumbing and electrical codes should be thoroughly under- stood and all pre-installation work arranged for accordingly. | 1. FACILITIES REQUIRED e The Super 20 must be mounted on a level concrete floor or a level concrete slab which has been secured to a concrete floor. e Individual hot and cold water supply valves with standard 3/4 inch male hose thread; SLIP-ON OR CLAMP-ON VALVE CONNECTIONS WILL NOT BE SATISFACTORY. ® Minimum flowing water pressure of 20 pounds per square inch. ® Minimum water flow rate of 3.8 gallons per minute. ® Floor drain or trough at rear of washer a maximum of 2 inches above the floor of the washer base (gravity drain models). | e Standpipe drain may be used with drain pump models. (Standpipe height should be a minimum of 24 inches or a maximum of 30 inches above the floor of the washer base.) ® 120/240 volt (or 120/208 volt), 60 Hertz AC power supply. 2. INSTALLATION MATERIALS Includes: 6— 20162 Washers 12-- 81121 Nuts 6. 81225 Mounting Bolts | - 81250 Anchoring Cement I — 81227 Template 6 — 91200 Lockwashers 3. TO INSTALL ON EXISTING CONCRETE FLOOR a. Place cardboard template on floor in exact spot where washer is to be located, and mark floor through holes marked SUPER 20. IMPORTANT: Size of template may change with humidity. Please check dimensions before using. See Figure 2. b. Drill six, 1-1/4 inch diameter holes in con- crete floor between 3 and 3-1/2 inches deep. See Figure I. c. Mark piece of 1/2 inch plywood (approxi- mately 30” x 30”) through holes marked SUPER 20 in cardboard template, and drill holes (1/2 inch diameter) in plywood. d. Fasten mounting bolts to plywood tem- plate with nuts. See Figure 1. ¢. Check dimensions from bolt to bolt to assure that bolts are located properly. See Figure 2 — SPEED QUEEN. f. Flush out holes in floor thoroughly with water. Sponge out water and leave sides of holes damp. g. Mix can of anchoring cement thoroughly with approximately 8 ounces of water. NOTE: batter”. Mix to consistency of “pancake h. Fill holes with anchoring cement and place mounting bolts (with template attached) into the holes. IMPORTANT: Anchoring cement must be in holes and bolts in anchoring cement within 10 minutes of mixing. i. Shim template until all mounting bolts are in holes same depth (bottom of thread even with floor). See Figure 1. j. Let anchoring cement dry for four hours before removing template and installing washer. PLYWOOD TEMPLATE FOR LOCATING BOLTS FINGER- MOUNTING BOLT > Figure 1 re 4. TO INSTALL ON CONCRETE SLAB a. Drill four, 1-1/4 inch diameter holes in concrete floor for tie bolts. Holes must be between 3 and 3-1/2 inches deep and slightly enlarged at the bottom. b. Flush out holes thoroughly with water. Sponge out water and leave sides of holes damp. c. Place four, 1/2 inch diameter steel tie-bolts (6 inch minimum length), with tack welded square washers attached, into center of holes, Figure 3. d. Mix can of anchoring cement thoroughly with approximately 8 ounces of water. NOTE: Mix to consistency of *“‘pancake e. Fill holes with anchoring cement, making sure bolts remain in a vertical position. IMPORTANT: Anchoring cement must be in holes within 10 minutes of mixing. f. Build a form around tie-bolts for slab, mak- ing provisions for 1-1/2 inch lip 3/4 inch wide, along the front and sides of the slab. See Figure 4. g. Place a 6 inch by 6 inch, 42 Ib. road mesh into the form, supporting it approximately 2 inches from floor. See Figure 4. | h. Pour concrete into form, using 3500 Ib. batter”. ready mixed cement. BULKHEAD \ COONAN N OUTLINE OF MACHINES | /N 18“ MIN. i 0 FA 1, ka _—_ TT ; | | | = 24-1/4" Je - — ol to : 38" | MOUNTING |! | à f | BOLTS | 139/16" | (6) ; | CENTER TO CENTER UT 2 + | | C--- = = = — © J Oo à 8-1/2" Y 1 J Y 6 > il 7 “if 27" o. 4 Mans asi 6" CENTER TO \ CENTER | Figure 2 SPEED QUEEN. 7 в PLYWOOD TEMPLATE FOR —_ —. LOCATINGBOLTS m IS => — À . у = a AD TACK WELD ce De 20. O SQUARE 7.04! o PLATE ; TO NUT os ть ' . A .. ut ! A A E , ANCHORING CEMENT Figure 1. Mark piece of 1/2 inch plywood (approxi- mately 30” x 30”) through holes marked SUPER 20 in cardboard template, and drill holes (1/2 inch diameter) in plywood. IMPORTANT: Size of template may change with humidity. Please check dimensions be- fore using. See Figure 2. J. Fasten mounting bolts to plywood tem- plate with nuts. See Figure 3 k. Check dimensions from bolt to bolt to assure that bolts are located properly. See Figure 2. I. Carefully place mounting bolts (with tem- plate attached) in wet concrete as shown in Figure 3. Level template from side to side and front to rear, making sure mounting bolts extend the length of the threads (2°) from concrete. m. If more than one washer is being installed, mounting bolts for adjacent washers should be at least 6 inches apart. See Figure 4. n. Allow concrete to cure at least 5 days. 1/2” BOLT TT FINGER-TIGHTEN NUTS 5" MIN. >> Pl — ле eo. "a | Зи 0 pers Le) pl as + “= 4 TnL ET oa a. ra . "a М Ё ve err es a EEE e Ar 1/2" STEEL 5-2 NA =" TIEBOLT ::5 3 2" 2-1/2" | Е POURED CONCRETE SLAB XISTING FLOOR 7 1-1/2" Figure 4 6” x 6”, 42 Ib. MESH RIT 4 1 rat 5. INSTALLING WASHER a. Remove air intake grille from front of washer and check mounting holes in base of washer to be sure they are not obstructed. b. Place washer over mounting bolts. c. Block washer up approximately 1/2 inch off floor, and pack space under outer angle of base with a grout specially formulated for wet areas. d. Remove blocks from under washer and po- sition No. 20162 washers, No. 91200 lock- washers, and No. 81121 nuts and locknuts on mounting bolts as shown in Figure 5 and tighten securely. e. Reinstall air intake grille, and clean up ex- cess grout from around washer base. IMPORTANT: Pump Models: When reinstall- ing air intake grille, insert end of overflow hose through hole in bottom of grille. NOTE: Use No. 81308 Top Conversion Kit if washer is to be “built-in”. IMPORTANT: Check mounting bolt nuts after first few loads. Nuts MUST be kept tight. *LOCKNUTS MUST BE USED AND TIGHTENED SECURELY. NUT LOCKWASHER. — —— — „= == == — — ——— Figure 5 В *LOCKNUT MOUNTING BOLT 6. WATER INLET HOSE CONNECTIONS Insert rubber washers (in accessories bag) in water inlet hose couplings (two hoses supplied with washer). Connect inlet hoses to water supply valves and flush lines for 3 to 5 minutes to remove foreign material from supply lines. Connect hoses to hot and cold valve connec- tions at rear of washer. IMPORTANT: Thread hose couplings onto valve body fingertight, then turn 1/4 turn with pliers. DO NOT overtighten couplings. Install risers, Figure 6, in water supply pipes if they knock or pound when flow of water stops. Install risers as close as possible to the water supply valves. 7. ELECTRICAL SERVICE IMPORTANT: DO NOT install washer if the electrical service is not the same as that speci- fied on serial plate on front base of washer, or serious damage may be caused to washer. The electrical service must be a separate, three-wire, 120/240 volt (washers are also available for 120/208 volt), 60 Hertz, single phase circuit fused with 15 ampere time delay fuses. To connect electrical service to washer (refer to Figure 7): a. Remove terminal block access plate from rear cross channel. b. Make certain inner nuts on terminal block are tight, then push ends of power cord or wires through hole in cross channel and fasten to terminal block posts using nuts and washers from accessories pack. c. Securety tighten outer nuts. The electrical installation should conform to the National Electric Code and such local regu- lations as might apply. The method of wiring is optional and subject to local code require- ments. 8. GROUNDING If permitted by local code, install an external ground wire. Connect one end to ground screw on rear cross channel, Figure 7, and the other end to a suitable ground, such as a cold water pipe or as required by local code. DO NOT GROUND WASHER TO A GAS PIPE OR HOT WATER PIPE. SPEED QUEEN. ( | | RISERS В | (AIR CUSHION) 7 | WATER WATER VALVES | SUPPLY | THREADED / FOR 3/4" | GARDEN HOSE | | CONNECTIONS | Figure 6 TERMINAL BLOCK O. O NEUTRAL WIRE IM GROUND SCREW == re E нат ey — ram N J Figure 7 9 LEN == Ee e | ° | Nu SN e. (41 Ё 1° \ | | : “| 1 | = | | I . SEALED DRAIN SYSTEM — VENT | | м MUST BE VENTED El (36” MIN. J ELO ° AHEAD OF ALL TRAPS M” HEIGHT) | По 1 NT BE | Lo ® 1 ul o , o И : 57 TRAP . Ne = A — _ REL ОЕ ИО TN ~ * 2 NN a Figure 8 9. DRAIN HOSE — Gravity Drain Models NOTE: If hose must be shortened to suit standpipe height, cut hose between formed Remove rear panel. The Super 20 is equipped end and elbow. Use sleeve and hose clamps with a short piece of hose attached to the drain (not supplied with washer) to connect hose tee that will accept 1-1/2 inch drain pipe. after gutting. (Inside diameter of hose is Fasten a 1-1/2 inch PVC Schedule 40 drain 1-1/8 = 1/32 inch.) pipe, which can be purchased at most hard- ware stores and plumbing shops, to the drain hose with hose clamp provided in accessories bag. The drain pipe must be installed to pitch 11. DRIVE BELT downhill, Figure $, for proper draining. REIN- STALL REAR PANEL. Remove rear panel and check drive belt for | proper belt tension. Proper tension is obtained IMPORTANT: When connecting a gravity when belt can be deflected approximately 1/2 drain model to a sealed drain system, install a inch from normal position when moderate vent stack (1-1/2” minimum diameter) at the pressure (5 1b.) is applied to a point midway point where the washer drain pipe is to con- between pulleys. nect to the drain system. The vent should be 3 to 4 feet high, located as closely behind the NOTE: No. 205P4, Belt Tension Meter > washer as possible and must be ahead of all available to aid in making exact belt adjust- traps in the drain system, Figure §. Observe ments. local codes. If adjustment is necessary, see ADJUST- MENTS section of service manual for proper 10. DRAIN HOSE — Pump Models procedure. REINSTALL REAR PANEL. Remove rear panel and fasten drain hose securely to outlet on pump cover with hose clamp from accessories pack. REINSTALL REAR PANEL. NOTE: The drive belt requires several cycles to achieve its permanent operating position in the pulleys. After 25 to 30 cycles, remove rear panel and recheck belt tension. RE- INSTALL REAR PANEL. - — SPEED QUEEN. ointenonce SECTION II IMPORTANT Rear panel MUST be installed before operating Super 20. The rear panel keeps dust and dirt from accumulating on the motor and adds rigidity to the structure of the washer. >, DAILY MAINTENANCE a ON (3 Wipe control panel, washer cabinet, and inside 7 № в of clothes cylinder using a clean cloth damp- неон | IMPORTANT | THIS DOOR MUST BE ened with clear water ONLY. 3. WEEKLY MAINTENANCE | a. Open dispenser door, Figure 9, and check | : a. > . KE ribs of dispenser boot for detergent build- PT CLOSED up. To clean dispenser boot area, fill a | small-necked glass jug with the hottest DISPENSER ___ pee a ALE DDR available tap water. Tip jug straight upside- down directly over the dispenser opening allowing the hot water to “glug” out onto the dispenser boot dissolving and washing away crusted detergent. b. Remove button trap and clean if necessary. OD | Figure 10 shows location of button trap _ | | behind air intake grille. When reinstalling DD button trap. be sure frame is in place and tightened securely to prevent a water leak. > Figure 10 TNT TT Te DOOR GLASS BRACKET —___ ÓN Figure 11 c. Check pump, hoses, drain valve and outer tub for leaks. d. Check washer mounting nuts — tighten if loose. PERIODIC MAINTENANCE a. Check the door glass bracket screws periodi- cally and tighten if necessary, Figure 11. b. Check water mixing valve screens for sedi- ment accumulation — clean or replace if necessary. c. Check drive belt for cracks or wear. Check belt tension and adjust if necessary. (See ADJUSTMENTS section of service manual.) d. Check water level in cylinder, Figure 12, and adjust pressure switch if necessary. (See ADJUSTMENTS section of service manual.) At the end of the fill portion, water depth in the cylinder should be approximately 4-1/2”. (Measure water depth with no ciothes in cylinder.) e. Lubricate blower motor with Speed Queen No. 20605 Hi-Temp Lube. (See Figure 10 for location of lubrication ports.) Do not over-lubricate. NOTE: By using an inexpensive syringe filled with lubricant, the needle end can be inserted into the lubrication parts and lubricant can be dispensed directly into the felt wicks. \- CLOTHES CYLINDER ON BAFFLES | 4 TO 5 INCH DEPTH > | A BOTTOM OF CYLINDER J Figure 12 a LUBRICATION E > >, PORTS | PUMP MOTOR Figure 13 f. Lubricate pump motor with Speed Queen No. 20605 Hi-Temp Lube. (See Figure 13 for location of lubrication ports.) Do not over-lubricate.
advertisement
Key Features
- stainless steel clothes cylinder
- 30 minutes complete cycle
- reversing timer
- 3.8 gpm water flow rate
- 120/240 volt, 60 Hertz electrical rating
Frequently Answers and Questions
How often should I clean the dispenser boot?
It is recommended to clean the dispenser boot weekly.
How do I adjust the drive belt tension?
Refer to the ADJUSTMENTS section of the service manual for proper procedure
What is the proper water depth in the cylinder?
At the end of the fill portion, the water depth should be approximately 4-1/2 inches.
How do I lubricate the blower motor?
Use Speed Queen No. 20605 Hi-Temp Lube.
How do I lubricate the pump motor?
Use Speed Queen No. 20605 Hi-Temp Lube.