SPEED QUEEN SUPER 20 CL8761, CL8763, CL8771, CL8773 washer User manual

SPEED QUEEN SUPER 20 CL8761, CL8763, CL8771, CL8773 washer User manual

Below you will find brief information for washer SUPER 20 CL8761, washer SUPER 20 CL8763, washer SUPER 20 CL8771. This manual will provide you with the steps needed to properly install and maintain your washer. This washer is a powerful machine that can handle even the toughest stains, and with the help of these instructions, you can keep it running smoothly for years to come.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

SPEED QUEEN SUPER 20 CL8761, CL8763, CL8771 user manual | Manualzz
INSTALLATION
and
MAINTENANCE
INSTRUCTIONS
(SPEED QUEEN.
— SUPER 20
WASHER - EXTRACTOR
p MODELS N
CL8761, CL8763,
CL8771& CL8773
\_
SPEED QUEEN
à Hipon. Wisconsin 549771
MINTE
mm 9
PART NO. 81216R8
Table of Contents
ROUGHING-IN DIMENSIONS | |
SPECIFICATIONS ................ PA naar 3
SECTIONI INSTALLATION
1. Facilities Required ............ —.eeeoc0oreaoreac ona onanonraronorerc 4
2. Installation Materials ..........ooe._eeexrecoredacoreaaderaceoonnoo, 4
3. To Install On Existing Concrete Floor .................. i. 5
4. To Install On Concrete Slab................. 0... ii, 6
S. Installing Washer ..........._ eee. .00r0ede dao nececenaoronna aora, 8
6. Water Inlet Hose Connections .................. esrredcereaarorareo 9
7. Electrical Service ......... nadadencoonoenecenreraoecr.reaeenea roce 9
8. Grounding 122001000000 aa a a a Le ee a a a de a de de aa aa aa aa aa 9
9. Drain Hose - Gravity Drain Models. ................. e. LL 10
10. Drain Hose — Pump Models. .......... cco. 10
11. Drive Belt ........... ........eeea00aearersececaooooaecaa)roereoo 10
SECTION II MAINTENANCE
12. Daily Maintenance ‚eK LL H
13. Weekly Maintenance .........eoéoexexosserecarreroorerencrerervdoednercaoo 11
14. Periodic Maintenance ...........c. iinet eee eae, 12
Roughing -in Dimensions
12-1/8” —-«——e
Ent
nil
Bios.
19-3/16”
SPEED QUEEN.
“a 47" | N чз”! I
=—16-3/4"— IN
— ль. : a | т |
\ В НН of ~ MOUNTING BOLT LOCATIONS
= «==> === [
ZN OE — В 3 —
— | — | '
— — | y | 27-3/16"
+ = = = -
| a XT —e
<< | | Î
— <
с 13-9/16"
(GRAVITY (PUMP . || |
DRAIN MODELS) MODELS) ne el tl
Е ЕЕ
: LLL НАД | 30" —
FRONT OF WASHER BASE
ное
Cpecfimtiona
Cabinet Finish:
Hi-baked acrylic enamel rear and side panels; stainless steel dis-
penser door, front panel and air intake grille, Porcelain cabinet top.
Height: 46-1/2 inches.
— Width: 30 inches.
I Depth:
= тт нашел CT 1 28 0e 0 a Em. wm + сн но - 4
Electrical Rating:
Drive Motor:
Blower Motor:
[ — .. Er A A a, A Mr ee
30-1/4 inches,
— A e Ps E Ad a
120/240 volt, 60 Hertz. Single phase, three wire, 10.5 amps. Also
available for 120/208 volt operation.
Internal overload protected. Wound for 230 volt, 60 Hertz opera-
tion at 3450 and 400 R.P.M. Also available for 208 voit operation.
Lifetime lubricated.
Wound for 115 volt, 60 Hertz operation at 3000 R.P.M.
Pump Motor: |
Models CL8763 & CL8773 Wound for 115 volt, 60 Hertz operation at 3000 R.P.M.
Clothes Cylinder: Stainless steel.
Cycle Timer:
Reversing Timer:
Water Mixing Valve:
— Weight:
30 minutes — complete cycle.
Reverses drive motor every 30 seconds in tumble portion of cycle.
3.8 gpm water flow rate.
418 Ibs. (approximate).
+r aa Aa
Installation section :
~—— IMPORTANT
WARRANTY IS VOID unless washer is installed according to instructions in )
this manual. Compliance with minimum specifications and requirements out-
lined in this manual and local building codes is a MUST! Because of varied
requirements, local plumbing and electrical codes should be thoroughly under-
stood and all pre-installation work arranged for accordingly. |
1. FACILITIES REQUIRED
e The Super 20 must be mounted on a level concrete floor or a level concrete slab which has been
secured to a concrete floor.
e Individual hot and cold water supply valves with standard 3/4 inch male hose thread; SLIP-ON OR
CLAMP-ON VALVE CONNECTIONS WILL NOT BE SATISFACTORY.
® Minimum flowing water pressure of 20 pounds per square inch.
® Minimum water flow rate of 3.8 gallons per minute.
® Floor drain or trough at rear of washer a maximum of 2 inches above the floor of the washer base
(gravity drain models). |
e Standpipe drain may be used with drain pump models. (Standpipe height should be a minimum of
24 inches or a maximum of 30 inches above the floor of the washer base.)
® 120/240 volt (or 120/208 volt), 60 Hertz AC power supply.
2. INSTALLATION MATERIALS
Includes:
6— 20162 Washers
12-- 81121 Nuts
6. 81225 Mounting Bolts
| - 81250 Anchoring Cement
I — 81227 Template
6 — 91200 Lockwashers
3. TO INSTALL ON EXISTING CONCRETE
FLOOR
a. Place cardboard template on floor in exact
spot where washer is to be located, and mark
floor through holes marked SUPER 20.
IMPORTANT: Size of template may change
with humidity. Please check dimensions
before using. See Figure 2.
b. Drill six, 1-1/4 inch diameter holes in con-
crete floor between 3 and 3-1/2 inches deep.
See Figure I.
c. Mark piece of 1/2 inch plywood (approxi-
mately 30” x 30”) through holes marked
SUPER 20 in cardboard template, and drill
holes (1/2 inch diameter) in plywood.
d. Fasten mounting bolts to plywood tem-
plate with nuts. See Figure 1.
¢. Check dimensions from bolt to bolt to
assure that bolts are located properly. See
Figure 2
— SPEED QUEEN.
f. Flush out holes in floor thoroughly with
water. Sponge out water and leave sides of
holes damp.
g. Mix can of anchoring cement thoroughly
with approximately 8 ounces of water.
NOTE:
batter”.
Mix to consistency of “pancake
h. Fill holes with anchoring cement and place
mounting bolts (with template attached)
into the holes.
IMPORTANT: Anchoring cement must be in
holes and bolts in anchoring cement within 10
minutes of mixing.
i. Shim template until all mounting bolts are
in holes same depth (bottom of thread even
with floor). See Figure 1.
j. Let anchoring cement dry for four hours
before removing template and installing
washer.
PLYWOOD TEMPLATE
FOR LOCATING BOLTS
FINGER-
MOUNTING BOLT
>
Figure 1
re
4. TO INSTALL ON CONCRETE SLAB
a. Drill four, 1-1/4 inch diameter holes in
concrete floor for tie bolts. Holes must be
between 3 and 3-1/2 inches deep and
slightly enlarged at the bottom.
b. Flush out holes thoroughly with water.
Sponge out water and leave sides of holes
damp.
c. Place four, 1/2 inch diameter steel tie-bolts
(6 inch minimum length), with tack welded
square washers attached, into center of
holes, Figure 3.
d. Mix can of anchoring cement thoroughly
with approximately 8 ounces of water.
NOTE: Mix to consistency of *“‘pancake
e. Fill holes with anchoring cement, making
sure bolts remain in a vertical position.
IMPORTANT: Anchoring cement must be in
holes within 10 minutes of mixing.
f. Build a form around tie-bolts for slab, mak-
ing provisions for 1-1/2 inch lip 3/4 inch
wide, along the front and sides of the slab.
See Figure 4.
g. Place a 6 inch by 6 inch, 42 Ib. road mesh
into the form, supporting it approximately
2 inches from floor. See Figure 4. |
h. Pour concrete into form, using 3500 Ib.
batter”. ready mixed cement.
BULKHEAD
\ COONAN N
OUTLINE OF MACHINES |
/N 18“ MIN.
i
0 FA 1, ka _—_
TT ;
| | |
= 24-1/4"
Je - — ol to :
38" | MOUNTING |! | à f
| BOLTS | 139/16"
| (6) ; | CENTER TO CENTER
UT 2 +
| |
C--- = = = — © J Oo à
8-1/2"
Y 1 J Y
6 > il 7 “if 27" o. 4 Mans asi 6"
CENTER
TO
\ CENTER |
Figure 2
SPEED QUEEN.
7
в
PLYWOOD TEMPLATE FOR —_ —.
LOCATINGBOLTS m IS => —
À
. у
= a AD
TACK WELD ce De 20. O
SQUARE 7.04! o
PLATE ;
TO NUT
os
ть '
. A .. ut !
A A E ,
ANCHORING
CEMENT
Figure
1. Mark piece of 1/2 inch plywood (approxi-
mately 30” x 30”) through holes marked
SUPER 20 in cardboard template, and drill
holes (1/2 inch diameter) in plywood.
IMPORTANT: Size of template may change
with humidity. Please check dimensions be-
fore using. See Figure 2.
J. Fasten mounting bolts to plywood tem-
plate with nuts. See Figure 3
k. Check dimensions from bolt to bolt to
assure that bolts are located properly. See
Figure 2.
I. Carefully place mounting bolts (with tem-
plate attached) in wet concrete as shown in
Figure 3. Level template from side to side
and front to rear, making sure mounting
bolts extend the length of the threads (2°)
from concrete.
m. If more than one washer is being installed,
mounting bolts for adjacent washers should
be at least 6 inches apart. See Figure 4.
n. Allow concrete to cure at least 5 days.
1/2” BOLT TT
FINGER-TIGHTEN NUTS 5" MIN.
>>
Pl
—
ле eo. "a | Зи
0 pers
Le) pl as + “= 4 TnL
ET oa a. ra
. "a М Ё ve err es a
EEE
e
Ar 1/2" STEEL 5-2
NA =" TIEBOLT ::5
3
2"
2-1/2"
| Е
POURED CONCRETE
SLAB
XISTING FLOOR
7
1-1/2"
Figure 4
6” x 6”, 42 Ib. MESH
RIT 4 1 rat
5.
INSTALLING WASHER
a. Remove air intake grille from front of
washer and check mounting holes in base of
washer to be sure they are not obstructed.
b. Place washer over mounting bolts.
c. Block washer up approximately 1/2 inch
off floor, and pack space under outer angle
of base with a grout specially formulated
for wet areas.
d. Remove blocks from under washer and po-
sition No. 20162 washers, No. 91200 lock-
washers, and No. 81121 nuts and locknuts
on mounting bolts as shown in Figure 5 and
tighten securely.
e. Reinstall air intake grille, and clean up ex-
cess grout from around washer base.
IMPORTANT: Pump Models: When reinstall-
ing air intake grille, insert end of overflow
hose through hole in bottom of grille.
NOTE: Use No. 81308 Top Conversion Kit
if washer is to be “built-in”.
IMPORTANT: Check mounting bolt nuts
after first few loads. Nuts MUST be kept tight.
*LOCKNUTS MUST BE USED
AND TIGHTENED SECURELY.
NUT
LOCKWASHER.
—
——
—
„= == ==
—
— ———
Figure 5
В
*LOCKNUT
MOUNTING BOLT
6. WATER INLET HOSE CONNECTIONS
Insert rubber washers (in accessories bag) in
water inlet hose couplings (two hoses supplied
with washer). Connect inlet hoses to water
supply valves and flush lines for 3 to 5 minutes
to remove foreign material from supply lines.
Connect hoses to hot and cold valve connec-
tions at rear of washer.
IMPORTANT: Thread hose couplings onto
valve body fingertight, then turn 1/4 turn with
pliers. DO NOT overtighten couplings.
Install risers, Figure 6, in water supply pipes
if they knock or pound when flow of water
stops. Install risers as close as possible to the
water supply valves.
7. ELECTRICAL SERVICE
IMPORTANT: DO NOT install washer if the
electrical service is not the same as that speci-
fied on serial plate on front base of washer, or
serious damage may be caused to washer.
The electrical service must be a separate,
three-wire, 120/240 volt (washers are also
available for 120/208 volt), 60 Hertz, single
phase circuit fused with 15 ampere time delay
fuses. To connect electrical service to washer
(refer to Figure 7):
a. Remove terminal block access plate from
rear cross channel.
b. Make certain inner nuts on terminal block
are tight, then push ends of power cord or
wires through hole in cross channel and
fasten to terminal block posts using nuts
and washers from accessories pack.
c. Securety tighten outer nuts.
The electrical installation should conform to
the National Electric Code and such local regu-
lations as might apply. The method of wiring
is optional and subject to local code require-
ments.
8. GROUNDING
If permitted by local code, install an external
ground wire. Connect one end to ground
screw on rear cross channel, Figure 7, and the
other end to a suitable ground, such as a cold
water pipe or as required by local code. DO
NOT GROUND WASHER TO A GAS PIPE
OR HOT WATER PIPE.
SPEED QUEEN.
( | | RISERS В
| (AIR CUSHION)
7
| WATER
WATER VALVES | SUPPLY
|
THREADED /
FOR 3/4" |
GARDEN HOSE | |
CONNECTIONS |
Figure 6
TERMINAL
BLOCK
O.
O NEUTRAL
WIRE IM
GROUND SCREW
== re
E нат ey — ram
N J
Figure 7
9
LEN
== Ee
e | ° | Nu
SN e. (41 Ё
1° \ | | : “| 1 | = |
| I . SEALED DRAIN SYSTEM — VENT
| | м MUST BE VENTED El (36” MIN.
J ELO ° AHEAD OF ALL TRAPS M” HEIGHT)
| По 1 NT BE
| Lo ® 1
ul o
, o
И : 57 TRAP
. Ne
= A — _ REL ОЕ ИО TN ~
* 2 NN a
Figure 8
9. DRAIN HOSE — Gravity Drain Models NOTE: If hose must be shortened to suit
standpipe height, cut hose between formed
Remove rear panel. The Super 20 is equipped end and elbow. Use sleeve and hose clamps
with a short piece of hose attached to the drain (not supplied with washer) to connect hose
tee that will accept 1-1/2 inch drain pipe. after gutting. (Inside diameter of hose is
Fasten a 1-1/2 inch PVC Schedule 40 drain 1-1/8 = 1/32 inch.)
pipe, which can be purchased at most hard-
ware stores and plumbing shops, to the drain
hose with hose clamp provided in accessories
bag. The drain pipe must be installed to pitch 11. DRIVE BELT
downhill, Figure $, for proper draining. REIN-
STALL REAR PANEL. Remove rear panel and check drive belt for
| proper belt tension. Proper tension is obtained
IMPORTANT: When connecting a gravity when belt can be deflected approximately 1/2
drain model to a sealed drain system, install a inch from normal position when moderate
vent stack (1-1/2” minimum diameter) at the pressure (5 1b.) is applied to a point midway
point where the washer drain pipe is to con- between pulleys.
nect to the drain system. The vent should be
3 to 4 feet high, located as closely behind the NOTE: No. 205P4, Belt Tension Meter >
washer as possible and must be ahead of all available to aid in making exact belt adjust-
traps in the drain system, Figure §. Observe ments.
local codes.
If adjustment is necessary, see ADJUST-
MENTS section of service manual for proper
10. DRAIN HOSE — Pump Models procedure. REINSTALL REAR PANEL.
Remove rear panel and fasten drain hose
securely to outlet on pump cover with hose
clamp from accessories pack. REINSTALL
REAR PANEL.
NOTE: The drive belt requires several cycles
to achieve its permanent operating position in
the pulleys. After 25 to 30 cycles, remove
rear panel and recheck belt tension. RE-
INSTALL REAR PANEL.
- — SPEED QUEEN.
ointenonce SECTION II
IMPORTANT
Rear panel MUST be installed before operating Super 20. The rear panel
keeps dust and dirt from accumulating on the motor and adds rigidity to the
structure of the washer.
>, DAILY MAINTENANCE a ON
(3
Wipe control panel, washer cabinet, and inside 7 № в
of clothes cylinder using a clean cloth damp- неон |
IMPORTANT |
THIS DOOR MUST BE
ened with clear water ONLY.
3. WEEKLY MAINTENANCE
|
a. Open dispenser door, Figure 9, and check |
: a. > . KE
ribs of dispenser boot for detergent build- PT CLOSED
up. To clean dispenser boot area, fill a |
small-necked glass jug with the hottest DISPENSER ___ pee a ALE DDR
available tap water. Tip jug straight upside-
down directly over the dispenser opening
allowing the hot water to “glug” out onto
the dispenser boot dissolving and washing
away crusted detergent.
b. Remove button trap and clean if necessary. OD |
Figure 10 shows location of button trap _ | |
behind air intake grille. When reinstalling DD
button trap. be sure frame is in place and
tightened securely to prevent a water leak.
>
Figure 10
TNT TT Te
DOOR GLASS
BRACKET —___
ÓN
Figure 11
c. Check pump, hoses, drain valve and outer
tub for leaks.
d. Check washer mounting nuts — tighten
if loose.
PERIODIC MAINTENANCE
a. Check the door glass bracket screws periodi-
cally and tighten if necessary, Figure 11.
b. Check water mixing valve screens for sedi-
ment accumulation — clean or replace if
necessary.
c. Check drive belt for cracks or wear. Check
belt tension and adjust if necessary. (See
ADJUSTMENTS section of service manual.)
d. Check water level in cylinder, Figure 12,
and adjust pressure switch if necessary. (See
ADJUSTMENTS section of service manual.)
At the end of the fill portion, water depth
in the cylinder should be approximately
4-1/2”. (Measure water depth with no
ciothes in cylinder.)
e. Lubricate blower motor with Speed Queen
No. 20605 Hi-Temp Lube. (See Figure 10
for location of lubrication ports.) Do not
over-lubricate.
NOTE: By using an inexpensive syringe filled
with lubricant, the needle end can be inserted
into the lubrication parts and lubricant can be
dispensed directly into the felt wicks.
\-
CLOTHES
CYLINDER
ON
BAFFLES
| 4 TO 5 INCH DEPTH
> |
A
BOTTOM
OF
CYLINDER
J
Figure 12
a
LUBRICATION E
>
>,
PORTS
| PUMP
MOTOR
Figure 13
f. Lubricate pump motor with Speed Queen
No. 20605 Hi-Temp Lube. (See Figure 13
for location of lubrication ports.) Do not
over-lubricate.

advertisement

Key Features

  • stainless steel clothes cylinder
  • 30 minutes complete cycle
  • reversing timer
  • 3.8 gpm water flow rate
  • 120/240 volt, 60 Hertz electrical rating

Frequently Answers and Questions

How often should I clean the dispenser boot?
It is recommended to clean the dispenser boot weekly.
How do I adjust the drive belt tension?
Refer to the ADJUSTMENTS section of the service manual for proper procedure
What is the proper water depth in the cylinder?
At the end of the fill portion, the water depth should be approximately 4-1/2 inches.
How do I lubricate the blower motor?
Use Speed Queen No. 20605 Hi-Temp Lube.
How do I lubricate the pump motor?
Use Speed Queen No. 20605 Hi-Temp Lube.

Related manuals

Download PDF

advertisement