Stovax 7118, 7101, 7102, 7119, 7160, 7127, 7130, 7161, 7100, 7162, 7117, 7120, 7163, 7103, 7104, 7105, 7113, 7113 LC, 7128, 7114, 7106, 7106 LC, 7106 HC, 7116, 7116 LC, 7116 HC Free Standing Stove User Instructions

Stovax 7118, 7101, 7102, 7119, 7160, 7127, 7130, 7161, 7100, 7162, 7117, 7120, 7163, 7103, 7104, 7105, 7113, 7113 LC, 7128, 7114, 7106, 7106 LC, 7106 HC, 7116, 7116 LC, 7116 HC Free Standing Stove User Instructions

Stovax 7118 is a free-standing stove designed for domestic heating purposes. It is suitable for burning approved fuels, including wood and smokeless fuels. The stove features a riddling grate system for easy ash removal. It is important to note that the stove should only be used in accordance with the manufacturer's operating instructions, and it should be installed by a competent installer in accordance with all local regulations. It is recommended to burn the stove at a low output for the first few days of use and to have it serviced annually by a competent service engineer.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Stovax Free Standing Stove 7118, 7101, 7102, 7119, 7160, 7127 User Instructions | Manualzz
L
I
M
I
T
E
D
Stockton 3/4/5/6/7/8/11
Free Standing Stove
ModelS: 7118/7101/7102/7119/7160/7127/7130/7161/7100/7162/7117/7120/7163/7103/7104/
7105/7113/7113LC/7128/7114/7106/7106LC/7106HC/7116/7116LC/7116HC
User Instructions
For Use in Great Britain and Eire
This product is suitable for use in the stated countries. To install the product in other countries it is essential to obtain translated instructions
and in some cases the product may require modification. Contact Stovax to obtain further information.
IMPORTANT
Please read these instructions carefully before using the appliance.
Keep them safe for future reference and when servicing the stove.
PM176-Issue 3 (April 2007)
FOR YOUR RECORDS
To assist us in any Guarantee claim please complete the following information:-
Stovax dealer appliance was purchased from
Name:..................................................................................................................................................................
Address:................................................................................................................................................................
. ...........................................................................................................................................................................
Telephone number:..............................................................................................................................................
Essential Information - MUST be completed
Date installed:......................................................................................................................................................
Model Description:...............................................................................................................................................
Serial number:......................................................................................................................................................
Installation Engineer
Company name:......................................................................................................................................................................
Address:..................................................................................................................................................................................
...............................................................................................................................................................................................
Telephone number:.................................................................................................................................................................
Commissioning Checks (to be completed and signed)
Is flue system correct for the appliance
YES
NO
Flue swept and soundness test complete
YES
NO
Smoke test completed on installed appliance
YES
NO
Spillage test completed
YES
NO
Use of appliance and operation of controls explained
YES
NO
Instruction books handed to customer
YES
NO
Signature:........................................................................................
Print name:................................................................
OPERATING INSTRUCTIONS
1.10 No other appliance should be connected to or share, the
same flue or chimney system.
1. GENERAL
1.1
1.11Do not store wood in the area beneath either the 5
Midline or 6 Highline stove.
This stove is designed for domestic heating and should
only be used for this purpose, and in accordance with the
manufacturers operating instructions.
SERIAL NUMBER
It should be installed by a competent installer, in
accordance with all local regulations, including those
referring to national and European standards.
1.12 The serial number will be required when ordering spare
parts or making warranty claims. It is found on the
data plate.
1.2
The stove should only be used to burn approved fuels
and should not be used with liquid fuels or used as an
incinerator.
1.13 Stockton 3, 4, 5, 6, 7, 8, 11
For most Stockton models the data plate is found under the
front of the stove ashlip.
1.3
As with all heating stoves the surfaces will become very
hot when in use, therefore due care should be taken
when near the stove. If it is to be used in the presence
of young children, elderly or infirm persons a suitable
fireguard should be used. Care should also be taken with
the placement of combustible items near the stove as
conducted and radiated heat could cause a fire hazard.
1.4
Stovax offer a wide range of firescreens and sparkguards,
along with a hearthgate system designed to offer full
protection for a range of stoves and fireplaces. Your Stovax
dealer can advise you on these products.
1.5
PR7540
Due to the high temperature of the convected air above
the stove we recommend that no valuable photographs,
paintings, TV screens, porcelain or other items are placed
in this area. Such artefacts may be damaged by long term
exposure to fluctuating temperatures.
1.6
The additional ventilation required for the safe use of this
stove should be kept free of any obstructions, both inside
and outside the building, at all times.
1.7
To burn solid fuel efficiently in a wood version the
multifuel kit should be fitted.
Multifuel kit part numbers:
Stove
Part No.
Stockton 5 (all)
7108
Stockton 6 (all)
7117
Stockton 7
7109
Stockton 8
7111
Stockton 8 Slimline
1.14 Stockton 5 Midline
The data plate is found on a swing out data plate located on
the back of the stove on the left hand side
PR7541
7111SL
Only for use with recommended fuels, see
Installation Instructions for full fitting details.
1.8
Have your Stovax product serviced annually by a competent
service engineer, and if repairs are required use only Stovax
approved spare parts.
1.9
Do not make unauthorised modifications or changes to
the stove.
OPERATING INSTRUCTIONS
AIR CONTROLS
Airwash Control
OPEN
2. USING THE STOVE FOR THE FIRST TIME
CLOSE
1 DOOR
2.1
When new, it is best to burn the fire at a low output for
the first few days of use. This will allow the construction to
settle and all fixing glues and paint to fully cure.
Avoid touching the paint during the first period of use.
2.2
During this time the stove may give off some unpleasant
odours, and we recommend that you keep the room well
ventilated during this period to avoid a build-up of fumes.
2 DOOR
PR7213
Primary Control
OPEN
3. BURNING WOOD
(with or without multifuel kit fitted)
PR7212
CLOSE
See instructions for detailed use of controls
3.1
Open the Airwash control fully and open the Primary air
control to approximately 25% open.
3.2
Place some pieces of firelighter or dry crumpled paper on
the grate and cover with some small pieces of dry kindling
wood. Light the paper or firelighters.
3.3
To avoid the build-up of condensation on the door glass
it is advisable to leave the door slightly open as the fire
establishes, and the glass warms.
3.4
As the fire becomes established add larger pieces of wood
and fully close the door. Do not leave the stove with the
door open as this could over-fire the stove and cause
permanent damage.
3.5
As the fire becomes established close the Primary air control
and control the burn rate using the Airwash control only.
3.6
To burn wood efficiently it is best to allow a bed of ash to
build-up on the grate, or the base of the stove, and control
the combustion using the Airwash control only.
3.7
Before re-fuelling the stove it is advisable to first rake the
embers evenly over the firebed then open the Airwash
control fully for a few minutes, to establish a glowing bed
before adding new logs.
3.8
Allow the new logs to burn at high output for a few minutes
before adjusting the burn rate, with the Airwash control,
to the desired setting. It is best to refuel little and often to
maintain clean and efficient burning.
3.9
The ideal control settings to suit the particular installation
and personal preferences will be established by experience
in using the stove.
DOOR HANDLE
To Open and Close
Drop tool over knob to fit. Lift and remove
1 DOOR
2 DOOR
PR7210
PR7209
Rotate 1/4 turn clockwise to open. Rotate 1/4 turn anti-clockwise to close.
Warning
Do not force the handle to turn more than 1/4 turn as damage may occur.
1.15 Never open the door with your bare hands.
1.16 Closing the door is the reverse of the previous.
MULTI-FUEL GRATE
1.17 To de-ash the firebed, using the riddling grate system,
operate by using the removable handle to pull the operating
knob in and out. This causes the ash to fall down into the
ashpan
1.18 Never operate the grate with your bare hands.
3.10 Do not load fuel higher than the log guard at the front of
the stove and the secondary combustion air inlet holes at
the back of the fire box.
Push/Pull to Operate
3.11 It is not recommended to load large amounts of logs and
burn with the Airwash control on low settings for long
periods of time. This will reduce the effectiveness of the
glass cleaning effect of the airwash. Also this will cause a
large build-up of tars and creosotes in the stove and flue
system.
PR7208
OPERATING INSTRUCTIONS
3.12 We would recommend that the stove be burnt at high
output for at least 30 minutes each day when it is in use.
This will help reduce the build-up of tars and creosotes
within the stove and flue system.
5. OVER-FIRING
5.1
Do not use the appliance at maximum output for prolonged
periods of time, or over fill the firebox with fuel, as this
could result in over-firing. If the connecting fluepipe,
appliance flue collar or top plate glow red with heat the
appliance is being over fired and the air controls should be
closed to reduce the output.
5.2
If a chimney fire occurs shut all air controls immediately to
close the appliance down, and evacuate all persons from
the building before calling the fire brigade. Do not re-enter
the building until it is confirmed safe to do so.
5.3
Following a chimney fire do not use the appliance until it
is inspected by a HETAS (GB only)/ INFO (Eire) registered
installer, to confirm that the appliance is safe to use, or
make any repairs required before re-use. Only genuine
Stovax replacement parts are to be used to keep your
appliance in safe and efficient working order.
5.4
After any chimney fire it is recommended that the chimney
system be inspected and swept by a NACS registered (UK
only) chimney sweep, to confirm that the system is structurally
sound and free from any obstructions before re-use.
4. BURNING SOLID FUEL
(with multifuel kit fitted)
Do not burn painted, impregnated wood or
manufactured board products.
4.1
Open the Airwash control to approximately 50% and
Primary air control fully.
4.2
Place some pieces of firelighter or dry crumpled paper on
the grate and cover with some small pieces of dry kindling
wood. Light the paper or firelighters.
4.3
To avoid the build-up of condensation on the door glass
it is advisable to leave the door slightly open as the fire
establishes, and the glass warms.
4.4
As the fire becomes established add pieces of solid fuel
and fully close the door. Do not leave the stove with the
door open as this could over-fire the stove and cause
permanent damage.
4.5
As the fire becomes established reduce the Airwash control
to approximately 25% and control the burn rate using the
Primary air control only.
4.6
To burn solid fuel efficiently it is best to control the
combustion using the Primary air control only.
4.7
Before re-fuelling the stove it is advisable to first de-ash the
firebed, using the riddling grate system. To do this open
the stove door, then using the ashpan tool move the grate
vigorously left to right. This causes the ash to fall down into
the ashpan. Do not use bare hands to operate the riddling
system.
4.8
4.9
6. seasonal use
Then open the Primary air control fully for a few minutes,
to establish a glowing bed before adding new fuel. Allow
the new fuel to burn at high output for a few minutes
before adjusting the burn rate with the Primary air control
to the desired setting. It is best to refuel little and often to
maintain clean and efficient burning.
6.1
If the stove is not to be used during the warmer periods of
the year it is recommended to clean and service the stove,
as detailed in the Maintenance and Servicing section.
6.2
The air controls should be set in the 50% open position to
keep the appliance ventilated, and stop the build-up of any
moisture inside.
6.3
Before re-lighting the stove remove the baffles, clear any
debris that may have accumulated, and check the flue is
clear of any blockages.
7. ASH REMOVAL
7.1
The burning of any fuel will produce ash, which will have
to be removed after a period of use. This time will depend
on the fuel used. Before removing the ash from the stove it
is advisable to let the fire burn down to a low level, or even
go out completely. If a multifuel kit is fitted the ashpan can
be removed from the stove using the tool provided, after
opening the door.
7.2
As heat can remain in the ash for a long period after use,
care must be taken when removing and carrying the full
ashpan. We suggest that the ashpan be carried using gloved
hands, or the ash is placed directly into a Stovax Ash Caddy.
(Stovax Part No. 4227).
7.3
When burning wood the amount of ash will be smaller and
may only need removal once every week. To do this, allow
the fire to burn out and cool. Then after removing the log
The ideal control settings to suit the particular installation
and personal preferences will be established by experience
in using the stove.
4.10 Do not load fuel higher than the log guard at the front of
the stove and the secondary combustion air inlet holes at
the back of the fire box.
4.11 We would recommend that the stove be burnt at high
output for at least 30 minutes each day when it is in use.
This will help reduce the build-up of tars and creosotes
within the stove and flue system.
Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels, as this will invalidate any product
guarantee.
OPERATING INSTRUCTIONS
retainer, scoop out the ash with a suitable shovel. It is best
to leave a layer of ash in the stove to form a bed for the
new fire.
7.4
9. burning performance
Do not place ash in a bin made from plastic or any other
combustible material.
8. RECOMMENDED FUELS
8.1
To help avoid large build-ups of tars and creosote within
the stove and the flue system, it is recommended to burn at
maximum output for at least 30 minutes each day. The use
of Stovax Protector chimney cleaner will also help to reduce
this problem.
8.2
Solid fuel: -Burn only manufactured smokeless fuels listed
as suitable for use with closed heating stoves. Do not burn
bituminous coal, ‘petro-coke’ or other petroleum based
fuels, as this will invalidate any product guarantee.
8.3
Fuel consumption at nominal heat output.
As tested to the requirements of EN13240 for nominal heat
output.
Stockton 3
1.4
Stockton 4
1.4
Stockton 5/5ML
1.5
Stockton 6/6HL
1.9
Stockton 72.4
Stockton 82.8
Stockton 113.5
Kg/Hour
Briquetted
Smokless Fuel
0.7
0.7
0.7
0.9
1.1
1.3
N/A
•
•
•
•
•
•
•
Difficulty getting a fire going and keeping it burning well,
Smoky fires with little flame,
Dirty glass,
Dirty firebricks,
Rapid creosote build-up in the chimney,
Low heat output,
Short burn times, excessive fuel consumption and blue/ grey smoke from the chimney.
Use only recommended solid fuels, which are approved for
use with closed appliances. Symptoms of poor performance
related to unsuitable fuels include:
•
•
•
•
•
•
Difficulty getting a fire going and keeping it burning well,
Smoky fires with little flame,
Dirty glass,
Dirty firebricks,
Short life span for grate, baffles and internal firebricks,
Permanent staining of glass.
9.3 Backpuffing
Use only seasoned wood with a moisture content of
less than 20%. Well seasoned logs should have the bark
beginning to lift and peel away, along with deep cracks
radiating from the centre of the log. Logs should feel lighter
than fresh cut wood of a similar size and sound hollow
when struck against each other. Logs should not feel damp
to the touch, have any visible moisture oozing from them or
moss and fungal growths on them.
Symptoms of poor performance related to wet woods
include:
9.2 Fuel Quality (Solid Fuel)
Fuel Consumption
Kg/Hour
Description
Wood
If you require advice on suitable solid fuels contact your
local Approved Coal Merchant. Details can be obtained by
ringing the Solid Fuel Association advice line on Freephone
0800 600 000. Or their web site at www.solidfuel.co.uk
A number of factors can affect the performance of the
Stockton stove. Some of these are listed.
9.1 Fuel Quality (Wood)
Wood: - Burn only seasoned timber, with a moisture
content of less than 20%. In most cases, this would require
drying cut wood for 12 to 18 months before use. Poor
quality timber could cause low combustion efficiency,
produce large amounts of harmful condensation, which
could reduce the effectiveness of the airwash system, and
ultimately the life of the stove.
Do not burn painted, impregnated wood or
manufactured board products.
Fuel consumption for canopy models is the same as
equivalent flat top model.
This is caused by a lack of combustion air entering the
firebox causing combustion gases to build up in the firebox
and periodically ignite as small explosions, causing smoke to
puff out of the appliance air inlets and other openings. The
problem will often occur if the air controls are shut soon
after adding new fuel to a very hot fire. To stop backpuffing
occurring open the air controls to increase the combustion
air and increase the burning rate.
OPERATING INSTRUCTIONS
9.4 Flue draught
be taken to use good quality kindling wood, when starting
the fire, and running the stove at a higher heat setting than
normal for a period after start-up to fully heat the chimney.
It could be possible to fit a rain cowl to the chimney to
reduce this problem. Your appliance installer should advise
you on possible solutions.
The chimney has two main functions, which are, to safely
remove the smoke, gases and fumes from the house, and
to provide a sufficient amount of draught (suction) in the
Stockton stove to ensure that the fire is kept burning.
Draught is caused by the rising hot air in the chimney when
the Stockton stove is lit.
Symptoms of poor performance related to flue draught
include:
• Excessive fuel consumption (high flue draught)
• Poor burning control, overheating (high flue draught)
• Wind noise from air controls (high flue draught)
• Difficulty getting a fire going and keeping it burning well
(low flue draught)
• Low heat output (low flue draught)
• Smoke entering room when doors opened (low flue draught)
The construction, position, size and height of the chimney
are all factors that affect the performance of the flue
draught.
If the Stockton stove emits smoke into the room
continuously close the air controls and allow the stove to go
out, and ventilate the room to clear the fumes.
Do not re-light the appliance until the cause of the
problem is identified and rectified.
10. TROUBLESHOOTING
STOVE GLASS BLACKENING:
This occurs as a result of four possible causes:
A.
Burning unseasoned wood – See page 8 (section 10.1) for more information on how to identify when your wood is ready for burning. Properly seasoned logs will have been kept for a minimum of a year but are best burnt at 2 years.
B.
The stove being burned at too low a temperature - A good working temperature is 300-500° F (120 – 250° C). A stove pipe thermometer will help identify this problem. (Stovax part no 3046). Burning the stove with the airwash control fully open for a period of around 20 minutes ought to cure this. This might be caused by damping your stove down overnight.
9.5 Weather conditions
C.
Problems with your flue – in particular insufficient air pull. If your flue is not doing its job efficiently this can cause blackening of the glass. A flue which is too short, experiences a downdraft, needs lining or has too many bends can promote blackening. If you suspect your flue may be contributing to the blackening of your stove glass you should contact the installer or a flue specialist.
RIDDLING MECHANISM JAMMING:
Other factors that can effect the flue draught include:
•
•
•
•
•
•
For advice on the correction of persistent flue problems
consult a qualified solid fuel heating engineer before
continuing to use the Stockton stove.
Trees or other buildings nearby causing turbulence
High and gusty winds
Outside temperature
Outside weather conditions
Incorrect additional ventilation to building
Blocked flue / chimney
The weather conditions outside the building could have an
effect on the burning performance of the Stockton stove.
These could include:
Windy days - smoking from the appliance. This could
be caused by turbulent airflow around chimney terminal,
possibly caused by the position of other buildings or
obstacles nearby. This problem is, also, sometimes
associated with oversize chimneys, which may even have
downdraught problems on calm days. If smoking is a
common problem on windy days make a note of the wind
strength and direction before consulting your appliance
installer, who will advise you on possible solutions to the
problem, after visiting the installation.
This occurs when fine ash builds up under the riddling mechanism preventing their movement. To prevent this we recommend that you follow a regular cleaning routine for the inside of your stove, taking care to lift out the riddling mechanism and remove all ash. Replace riddling grate when cleaning is complete.
STOVE GLASS CRACKING:
Damp / Rainy days – These sometimes result in problems
when lighting and maintaining the fire, due to the lower
flue temperatures and smaller difference between indoor
and outdoor temperatures reducing the flue draught. Also,
rain water running down the inside of the chimney reduces
the flue temperatures. To help with this problem care must
Please ensure when replacing the glass in your stove that you do not over tighten the screws on the glass clips as this will cause stress in the glass and with the intense heating and cooling of burning your stove it may well cause the glass to crack.
OPERATING INSTRUCTIONS
STOVE IS PRODUCING TAR:
You can recognise this from the following traits:
Very strong pungent smell shortly after the stove is lit and as the stove heats up, glass blackening and, possibly, can be seen as a thick, brown and sticky material oozing from your stove pipe joints.
This is caused by burning damp wood and burning your stove at too low a temperature. To resolve this only use well seasoned wood and ensure your stove is operating in the ideal temperature range. Tar is a major cause of chimney fires - if you experience problems with tar build up, please consult a chimney sweep before continued use of your stove.
Ideal working temperature range is 130°C and 240°C (270°F – 465°F). If you fail to close down your primary air control once the stove has heated up to this range you may cause your stove to overfire and the temperature to exceed the ideal range. Overfiring can cause permanent damage to your stove and will invalidate your warranty.
HINGE PIN RIDING UP:
This occurs when the hinge block has moved out of
alignment. To correct this adjust the hinge blocks back to
the vertical position. See section 10 page 12 for information
on adjusting the door hinges.
MAINTENANCE and SERVICING
See chart on page 10 for common spare parts refered to in this section.
For a complete list of spare parts and accessories contact your Stovax dealer for the
Stovax Fireplace, Stove & Hearth Accessories brochure or call 01392 474011
1. GENERAL CLEANING
Before any cleaning is carried out, allow stove to cool
thoroughly to avoid risk of burns.
1.1
We would recommend that your Stockton stove be cleaned
fully on a regular basis, according to the level of use.
Attention should be given to cleaning the baffle system,
flueways and removing ash. Regular cleaning and preventive
maintenance will help give many years of safe use.
1.2
The external paintwork may be cleaned using warm soapy
water and a soft clean cloth. Wipe dry with a soft clean
cloth before re-lighting. Do not leave unit without drying, as
this may cause rust.
2. CLEANING GLASS
2.1
While the correct use of the Airwash system, and good
quality fuel, will generally keep the glass clean when the
appliance is used you may sometimes need to clean the
glass.
2.2
This can be done as follows. Allow the Stockton stove to
cool fully, never attempt to clean hot glass. Any deposits
can be removed using a soft cloth and Stovax Glass Cleaner.
2.3
Before re-lighting the appliance, dry the glass fully.
2.4
Do not use abrasive cleaner or cleaning pads.
4.1
4.3
Clean the internal surfaces of the stove using a wire brush
and scraper as required. Vacuum and brush the resulting
debris from the stove.
4.4
Clean the baffle and grate parts with a wire brush, and
check the parts for any damage. Replace any damaged
parts.
4.5
Check and clean the firebricks with a soft brush. Replace
any broken bricks. It is normal for some surface damage to
occur during use.
4.6
Re-fit cleaned internal parts.
4.7
Remove the glass from the door, see section 8, and discard
all old rope seals.
4.8
Remove the door rope seal from the outer edge of the door
and clean the old glue from the door sealing rope grove.
4.9
Clean the door glass using Stovax Stove Glass Cleaner and
a soft cloth, do not use abrasive cleaners to remove tar or
soot deposits from the glass.
4.11 Fit new door rope seal with the joint in the middle of
the lower edge of the door, gluing it in place with Stovax
Thermic Seal rope adhesive (See section 9, page 12). When
fitting new door seals we recommend closing the stove door
and leaving for at least 12 hours before using. This allows
the adhesive to fully bond to the seal before use.
We would recommend that to maintain the safe and
efficient use of the appliance the flue / chimney is inspected
and swept at least once a year, by a NACS Registered
(UK only) / INFO Registered (Eire only) chimney sweep,
who will issue you with a certificate.
4.12 Lightly oil the door catch mechanism and hinge pins. Avoid
getting oil onto the door seals and glass.
4.13 To refresh painted finishes it is possible to re-paint using
Stovax Thermolac stove paint.
4.14 We recommend that only genuine Stovax replacement
parts are used to keep your appliance in safe and efficient
working order. Your local Stovax dealer will be able to
provide you with the genuine parts you require.
4. ANNUAL SERVICE
Vacuum clean any remaining ash and debris from the inside
of the stove. Stovax offer a filter / collection attachment for
your vacuum cleaner to protect it from fine ash. Ash clean
(Stovax Part No. 2091).
4.10 Replace the glass edge seal with new and re-fit the glass into
place in the door. (See section 8, page 11).
3. CHIMNEY SWEEPING
3.1
4.2
At the end of the heating season it is recommended to strip,
inspect and clean the stove as detailed: -
Carefully remove all of the following internal parts. 2
internal baffles, firebricks, complete grate (2 parts), and
ashpan. See sections 6 and 7 for the instructions on how
to remove the baffles and firebricks. Care should be taken
when handling firebricks, as they can become fragile after a
period of use.
MAINTENANCE and SERVICING
4.15 This is a list of the maintenance products you may need
to use
Task
Product name
Glass cleaning
Stove glass cleaner 500ml
(wipe on)
Stove glass cleaner
(spray on)
Preventing build-up Protector (15 sachets)
of creosote in flue Protector (1kg tub)
5. REMOVAL OF THE LOG GUARD
5.1
4111
Remove the log guard by lifting clear of the supporting
brackets and rotating to clear the sides of the door opening.
The stove should not be used without the log guard in
position.
4130
6. FITTING AND REMOVAL OF BAFFLE
Stovax Code
Number
7002
7025
Sealing flue
pipe joints
Re-painting
Cleaning matt black stoves
Fire Cement (500g tub)2020
Fire Cement (600g cartridge)2021
Thermolac Black
2019
(400ml aerosol)
Thermolac Black
2057
(9200ml brush-on)
Colloidal black (85ml)
7000
Protecting your
hands
Heat resistant leather gloves
Door sealing rope
14mm Black rope seal
(handy pack)
Glass sealing tape
14mm Black rope seal
(25m reel)
3mm Black rope seal
(handy pack)
3mm Black rope seal
(25m reel)
Fixing rope seal
Ash Clean
Thermic seal glue
5037
(50ml bottle)
Vaccuum Cleaner Attachment2091
6.1
To maintain efficient combustion the stove is fitted with a
baffle in the top of the firebox.
6.2
Allow the stove to cool fully before removing the baffle
system.
6.3
To remove the baffle, first remove the log guard from the
stove to give access to the firebox.
6.4
Remove the baffle by lifting the front edge to clear the
support bars, then pull the baffle forward to disengage the
rear edge from the location above air inlet holes. Rotate
the baffle to remove from the firebox through the door
opening.
4008
5000
4670
4975
4974
4.16 These products, all available from your local Stovax dealer,
along with regular maintenance and use of correct fuels, will
help you to keep your stove in the best condition.
Support Pin
6.5
4.17 If you require more information about Stovax group
products, visit ouor website www.stovax.com.
PR7214
The replacement of the system is the reverse of the previous
operations, ensuring it is replaced the correct way around.
4.18 When using the stove for the first time again it is best to
burn the fire at a low output for the first day of use. This
will allow the new seals to settle and all new fixing glues
and paint to fully cure.
4.19 During this time, the stove may give off some unpleasnt
odours, and we recommend that you keep the room well
ventialted during thsi period to avoid a build-up of fumes.
Front
4.20 If you require help, your local Stovax dealer will be able to
carry out all of your service and maintenance requirements
for a reasonable cost.
PR7076
10
MAINTENANCE and SERVICING
6.6
6.7
6.8
Single Door
It is important to remove and clean the baffle system to
ensure the flue ways are clear of soot and debris and to
ensure the safe and efficient operation of the stove. The
frequency of cleaning will depend on the stove operating
conditions.
Fixing Screws (x4)
Fixing Clips (x4)
The baffle system is designed to give safe and efficient
operation of the stove. Replace any damaged baffles
immediately.
Glass
Do not modify the baffle system.
Glass Seal
7. FITTING & REMOVAL OF FIREBRICKS
7.1
As part of the routine maintenance of the stove you may
have to remove the firebricks from the stove. This can be
carried-out without the use of tools, but the bricks must be
removed and replaced as shown, after removing the baffle
system.
7.2
Allow the stove to cool fully before removing firebricks.
7.3
If your stove is fitted with 4 upper firebricks, remove the
lower 2 bricks first. Then lower the top bricks and remove.
Door
PR7080
Double Door
Fixing Screws (x10)
Fixing Clips (x4)
Fixing Clip Long (x2)
Glass (x2)
Glass Seal (3mm)
PR7211
7.4
Replace the bricks in the reverse order of removal.
7.5
Care should be taken when handling bricks, as they can
become fragile after a period of use. This is normal and
the life will depend on the type of fuels burnt and the level
of use. Damaged bricks should be replaced as soon as
possible, and can be purchased from your Stovax dealer.
Door (x2)
PR7081
8. FITTING A NEW DOOR GLASS
8.1
8.2
To maintain the safe use of your stove you may need to
replace a damaged door glass. To complete this operation,
use this method.
Remove the door, by opening and lifting the door free of
the hinge blocks. Then lie the door face down on a soft flat
surface, to protect the paintwork and glass.
11
8.3
Using a screwdriver remove the glass clip fixing screws (4).
The old glass can then be lifted clear of the door. (Note
how the 3mm sealing rope is placed between the glass and
the door.) Remember to dispose of the old glass safely.
8.4
Clean, and re-paint, the rear of the door if required. Clean
the screws with light oil and coat with high temperature
anti-seize grease, this will aid future removal.
8.5
Fit a new sealing rope between the new glass and the door,
and place the glass into position in the door. Place the glass
fixing clips into position and re-fix with the clean fixing
screws, tighten the screws evenly until the clips hold the
glass. Do not over tighten the clips as this could break the
glass.
MAINTENANCE and SERVICING
8.6
8.7
Fit only Stovax ceramic glass, which is suitable to use in
high temperature applications.
9.6
Using the stove with a damaged door glass could cause
dangerous fumes to enter the room, or the stove to overfire,
resulting in damage.
Using the stove with a damaged door seal could cause
dangerous fumes to enter the room, or the stove to overfire,
resulting in damage.
10. ADJUSTING DOOR HINGES
9. fitting a new door seal
9.1
9.2
10.1 To maintain the safe use of your Stockton stove, you may
need to adjust the door hinges to ensure safe correct closing
of the door. Complete this operation as follows.
To maintain the safe use of your stove you may need to
replace a damaged or worn door sealing rope. To complete
this operation, use this method.
10.2 Open the door to give access to the fixed part of the door
hinge as shown.
Remove the door from the stove, by opening and lifting the
door free of the hinge blocks. Then lie the door face down
on a soft flat surface, to protect the paintwork and glass.
Single Door
Seal 14mm
Fixing Nut
Lock Nut
PR7087
PR7086
10.3 Using a 19mm A/F spanner loosen the fixing nuts, as shown,
and reposition the hinge blocks to achieve a correct fit. This
may require a trial and error approach to find the correct
position.
Joint
Double Door
PR7084
Seal 14mm
Seal 10mm x 2mm
PR7085
9.3
Remove the old rope and scrape old glue from the locating
groove. Clean the locating groove with a clean dry cloth to
remove all old dust and debris.
9.4
Squeeze a generous bead of fresh Stovax Thermic Seal glue
(Stovax Part No. 5037) into the rope locating groove. Press
the new Stovax rope into the locating groove, placing the
joint in the middle of the lower edge of the door.
9.5
Refit the door and close the door to apply pressure to
new rope. Leave the stove closed for at least 12 hours
before lighting the stove and using at a low output for
approximately one day.
12
13
14
CARE OF YOUR STOCKTON
To help you get the best performance from your Stockton and keep it in good condition, inside and out, Stovax offers a wide range of
cleaning and maintenance products as well as a host of accessories to help you enjoy the maximum pleasure from your stove. Your Stovax
retailer will be able to provide full details but here is a brief list of items that may be of interest:
Product Description
Code
3047
Extra long matches
5039
Gas lighter
4052
Log basket
3048
Wood sling - for easy carrying of logs
3016
Log tongs
Extra long protective gloves
4027
3046
Stove pipe thermometer
Hearthgate - 5 section (for areas 1780x610mm)
5038
5044
Hearthgate - 7 section (for areas 1780x405mm)
4227
Ash caddy - All models except Stockton 11MF
4228
Ash caddy - Stockton 11MF only
2091
Ashclean vacuum cleaner attachment
Steel brush
4232
Your retailer will also be able to provide genuine spare parts such as replacement glass, door sealing rope and fire bricks, as and when
required. Remember, an annual service is recommended to keep your appliance in best possible condition.
15
L
I
M
I
T
E
D
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF
Tel: (01392) 474011 Fax: (01392) 219932 E-mail: [email protected] www.stovax.com

advertisement

Key Features

  • Domestic heating
  • Solid fuel burning
  • Airwash system
  • Safety features
  • Multifuel kit
  • Easy to clean

Frequently Answers and Questions

How do I start a fire in my Stockton stove?
Refer to the "Burning Wood" or "Burning Solid Fuel" sections in the instructions for a step-by-step guide on how to start a fire in your stove.
What type of fuel should I use in my Stockton stove?
This stove is designed to burn approved fuels and should only be used for this purpose. Refer to the "Recommended Fuels" section in the instructions for a list of suitable fuels.
What should I do if my stove glass blackens?
Blackening of the stove glass can be caused by several factors, including burning unseasoned wood, burning the stove at too low a temperature, or problems with your flue. Refer to the "Troubleshooting" section for more information and possible solutions.

Related manuals

Download PDF

advertisement