SUPERMICRO SUPERSERVER 5014C-MF server User's Manual

SUPERMICRO SUPERSERVER 5014C-MF server User's Manual

Below you will find brief information for server SUPERSERVER 5014C-MF. The Supermicro SuperServer 5014C-MF is a high-end single processor, 1U rackmount server with state-of-the-art features. The 5014C-MF is comprised of two main subsystems: the SC513L-260 1U chassis and the P8SCT motherboard. The P8SCT supports single Intel® Pentium® 4 LGA775 ("Prescott") type processors at an 800 MHz FSB or single Intel® Celeron® processors at a 533 MHz FSB.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

SUPERSERVER 5014C-MF User's Manual | Manualzz
SUPER
®
SUPERSERVER 5014C-MF
USER’S MANUAL
Revision 1.0a
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of
this manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this
manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any
medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE
OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE
LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE
PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING
OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all
claims will not exceed the price paid for the hardware product.
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2005 by SUPER MICRO COMPUTER INC.
All rights reserved.
Printed in the United States of America
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 5014C-MF. Installation and maintainance should be performed by experienced technicians only.
The SuperServer 5014C-MF is a high-end single processor 1U rackmount server
based on the SC513L-260 server chassis and the Super P8SCT motherboard. The
P8SCT supports single Intel® Pentium® 4 LGA775 ("Prescott") type processors at
an 800 MHz FSB or single Intel® Celeron® processors at a 533 MHz FSB.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with the
server system and describes the main features of the Super P8SCT motherboard
and the SC513L-260 chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 5014C-MF
into a rack and check out the server configuration prior to powering up the system. If
your server was ordered without the processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions
and information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
SUPERSERVER 5014C-MF User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 5014C-MF.
Chapter 5: Advanced Motherboard Setup
Chapter 5 provides detailed information on the P8SCT motherboard, including the
locations and functions of connectors, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfiguring the
motherboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC513L-260 1U rackmount server
chassis. You should follow the procedures given in this chapter when installing,
removing or reconfiguring Serial ATA or peripheral drives and when replacing system
power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: Software Installation
Appendix D: System Specifications
iv
Preface
Notes
v
SUPERSERVER 5014C-MF User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1
Overview ......................................................................................................... 1-1
1-2
Motherboard Features .................................................................................... 1-2
1-3
Server Chassis Features ................................................................................ 1-5
1-4
Contacting Supermicro ................................................................................... 1-7
Chapter 2: Server Installation
2-1
Overview ......................................................................................................... 2-1
2-2
Unpacking the System ................................................................................... 2-1
2-3
Preparing for Setup ........................................................................................ 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions .................................................................................... 2-2
Server Precautions ................................................................................. 2-2
Rack Mounting Considerations ............................................................... 2-3
2-4
Installing the System into a Rack ................................................................... 2-4
Basic Installation Procedure ................................................................... 2-4
Installing with Optional Rackmount Kit ..................................................... 2-4
Installing the Chassis Rails ....................................................................... 2-5
Installing the Rack Rails ............................................................................ 2-6
Installing the Server into the Rack ............................................................ 2-6
Installing the Server into a Telco Rack ..................................................... 2-7
2-5
Checking the Motherboard Setup .................................................................. 2-9
2-6
Checking the Drive Bay Setup ....................................................................... 2-9
Chapter 3: System Interface
3-1
Overview ......................................................................................................... 3-1
3-2
Control Panel Buttons .................................................................................... 3-1
Reset ....................................................................................................... 3-1
Power ...................................................................................................... 3-1
3-3
Control Panel LEDs ........................................................................................ 3-2
Overheat/Fan Fail
.................................................................................. 3-2
NIC2 ........................................................................................................ 3-2
NIC1 ........................................................................................................ 3-2
vi
Table of Contents
HDD ........................................................................................................ 3-2
Power ...................................................................................................... 3-3
Chapter 4: System Safety
4-1
Electrical Safety Precautions ........................................................................... 4-1
4-2
General Safety Precautions ............................................................................. 4-2
4-3
ESD Precautions ............................................................................................ 4-3
4-4
Operating Precautions .................................................................................... 4-4
Chapter 5: Advanced Motherboard Setup
5-1
Handling the Motherboard ............................................................................... 5-1
5-2
Motherboard Installation .................................................................................. 5-2
5-3
Connecting Cables .......................................................................................... 5-3
Connecting Data Cables ........................................................................... 5-3
Connecting Power Cables ......................................................................... 5-3
Connecting the Control Panel ................................................................... 5-3
5-4
I/O Ports........................................................................................................... 5-4
5-5
Installing the Processor ................................................................................... 5-5
5-6
Installing Memory............................................................................................. 5-8
5-7
Adding PCI Cards ............................................................................................ 5-9
5-8
Motherboard Details ...................................................................................... 5-10
P8SCT Layout ......................................................................................... 5-10
P8SCT Quick Reference ......................................................................... 5-11
5-9
Connector Definitions .................................................................................... 5-12
Power Supply Connectors .................................................................... 5-12
PWR_ON Connnector ............................................................................. 5-12
Reset Connector ................................................................................... 5-12
Overheat LED (OH) ................................................................................. 5-13
NIC2 (JLAN2) LED .................................................................................. 5-13
NIC1 (JLAN2) LED .................................................................................. 5-13
IDE/SATA LED ......................................................................................... 5-13
Power On LED ........................................................................................ 5-14
NMI Button .............................................................................................. 5-14
Fan Headers............................................................................................ 5-14
ATX PS/2 Keyboard and PS/2 Mouse Ports ........................................... 5-14
Chassis Intrusion ..................................................................................... 5-15
Universal Serial Bus (USB) ..................................................................... 5-15
Wake-On-LAN ......................................................................................... 5-15
JLAN1/2 (Ethernet Ports) ........................................................................ 5-15
vii
SUPERSERVER 5014C-MF User's Manual
Wake-On-Ring ......................................................................................... 5-16
SATA LED ................................................................................................ 5-16
Serial Ports ............................................................................................. 5-16
Power LED .............................................................................................. 5-16
5-10 Jumper Settings ............................................................................................. 5-17
Explanation of Jumpers ........................................................................... 5-17
CMOS Clear ............................................................................................ 5-17
Speaker Connector ................................................................................. 5-17
USB Wake-Up ......................................................................................... 5-18
Keyboard Wake-Up ................................................................................. 5-18
System Force Power On ......................................................................... 5-18
Watch Dog Enable/Disable ..................................................................... 5-19
JLAN1/JLAN2 Enable/Disable ................................................................. 5-19
SMBus to PCI.......................................................................................... 5-19
PCI-X Slot Speed Select ......................................................................... 5-20
CPU Front Side Bus Speed .................................................................... 5-20
5-11 Onboard Indicators ........................................................................................ 5-20
JLAN1/JLAN2 LEDs ................................................................................ 5-20
5-12 Parallel Port, Floppy and IDE Drive Connections ......................................... 5-21
Parallel Port Connector ........................................................................... 5-21
Floppy Connector .................................................................................... 5-22
IDE Connector ......................................................................................... 5-23
Chapter 6: Advanced Chassis Setup
6-1
Static-Sensitive Devices .................................................................................. 6-1
6-2
Control Panel ................................................................................................... 6-2
6-3
System Fan...................................................................................................... 6-3
System Fan Failure ................................................................................... 6-3
6-4
Drive Bay Installation/Removal ........................................................................ 6-3
Accessing the Drive Bay ........................................................................... 6-3
Serial ATA Drive Installation ...................................................................... 6-4
6-5
Power Supply................................................................................................... 6-6
Power Supply Failure ................................................................................ 6-6
Replacing the Power Supply ..................................................................... 6-6
Chapter 7: BIOS
7-1
Introduction ...................................................................................................... 7-1
7-2
Running Setup ................................................................................................. 7-2
7-3
Main BIOS Setup ............................................................................................ 7-2
7-4
Advanced BIOS Setup ................................................................................... 7-5
viii
Table of Contents
7-4.1 Advanced BIOS Features .............................................................. 7-5
7-4.2 Advanced Chipset Control ............................................................. 7-6
7-4.3 I/O Device Configuration ............................................................... 7-8
7-4.4 PnP/PCI Configuration .................................................................. 7-9
7-4.5 Hardware Monitors ...................................................................... 7-11
7-4.6 Processor & Clock Options ......................................................... 7-12
7-4.7 DMI Event Log ............................................................................. 7-13
7-4.8 Console Redirection .................................................................... 7-14
7-5
Security .......................................................................................................... 7-15
7-6
Boot .............................................................................................................. 7-16
7-7
Exit ................................................................................................................ 7-17
Appendices:
Appendix A: BIOS POST Messages ......................................................................... A-1
Appendix B: BIOS POST Codes ............................................................................... B-1
Appendix C: Software Installation ............................................................................ C-1
Appendix D: System Specifications ......................................................................... D-1
ix
SUPERSERVER 5014C-MF User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1
Overview
The Supermicro SuperServer 5014C-MF is a high-end single processor, 1U rackmount server with state-of-the-art features. The 5014C-MF is comprised of two main
subsystems: the SC513L-260 1U chassis and the P8SCT motherboard. Please
refer to our web site for information on operating systems that have been certified
for use with the 5014C-MF.
In addition to the mainboard and chassis, various hardware components may have
been included with the 5014C-MF, as listed below.
One CPU heatsink (SNK-P0011)
One (1) 10-cm blower fan (FAN-0059)
One (1) fan holder (CSE-PT64)
One (1) 1U air shroud (CSE-PT62)
One (1) SATA cable (CBL-0061)
One (1) IDE cable (CBL-0036)
Rackmount hardware with screws (optional, CSE-PT8):
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails in a rack/telco rack
One (1) CD containing drivers and utilities
SuperServer 5014C-MF User's Manual
Note: "B" indicates black.
1-1
SUPERSERVER 5014C-MF User's Manual
1-2
Motherboard Features
At the heart of the SuperServer 5014C-MF lies the P8SCT, a single processor
motherboard based upon Intel's E7221 chipset. Below are the main features of
the P8SCT.
Processor
The P8SCT has a single LGA775 ZIF socket to support an Intel® Pentium® 4
("Prescott" type) processor with hyper-threading technology at an 800/533 MHz FSB
speed or a single Intel® Celeron® processor at a 533 MHz FSB speed. Please refer
to the support section of our web site for a complete listing of supported processors
(http://www.supermicro.com/support/).
Memory
The P8SCT has four (4) 240-pin DIMM sockets that can support up to 4 GB of
unbuffered ECC type DDR2-533/400 SDRAM modules. The P8SCT's dual-channel
memory bus requires modules to be populated in pairs. All memory modules must
be the same size and speed.
Serial ATA
A Serial ATA controller is incorporated into the ICHR6 (South Bridge) portion of the
E7221 chipset to provide a four-port Serial ATA subsystem, which is RAID0, RAID1
and RAID 10 supported. The drive may also be used in a JBOD configuration.
Only a single hard drive may be installed in the system. The Serial ATA drive is
not hot-swappable.
PCI Expansion Slots
The P8SCT has one 64-bit 133 MHz PCI-X slot and five 32-bit PCI slots. One riser
card is included with the system (see Chapter 5 for details).
Ethernet Ports
Two onboard Broadband BCM5721 Ethernet controllers are integrated into the
P8SCT to support two Gigabit LAN (Ethernet) ports.
1-2
Chapter 1: Introduction
Onboard Controllers/Front Side Ports
An onboard IDE controller supports one floppy drive and up to four Ultra ATA 100
hard drives or ATAPI devices. Front side ports include one COM port, one parallel
(printer) port, two USB ports, PS/2 mouse and keyboard ports, a graphics port and
two Gigabit LAN (NIC) ports.
Other Features
Other onboard features that promote system health include voltage monitors, a
chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3
SUPERSERVER 5014C-MF User's Manual
Figure 1-1 . Intel E7221 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
1-4
Chapter 1: Introduction
1-3
Server Chassis Features
The SuperServer 5014C-MF is built on the SC513L-260 1U rackmount server
chassis. The SC513L-260 features a unique design that places all I/O ports at the
front of the chassis for easy access. The following is a general outline of the main
features of the SC513L-260 chassis.
System Power
When configured as a SuperServer 5014C-MF, the SC513L-260 chassis includes
a single 260W power supply.
Serial ATA Subsystem
The SC513L-260 chassis was designed to support one internal 3.5" Serial ATA hard
drive. This Serial ATA drive is not hot-swappable; power must be removed from
the system before installing or replacing. ATA/100 IDE drives can be alternately
supported.
Control Panel
The control panel on the SC513L-260 provides important system monitoring and
control information. LEDs indicate power on, network activity, hard disk drive activity and system overheat conditions. The control panel also includes a main power
button and a system reset button.
Front I/O Panel
The I/O panel for the SC513L-260 is located on the front side of the chassis. It
provides one COM port, two USB ports, PS/2 mouse and keyboard ports, a graphics port and two Gb Ethernet ports. (See Figure 1-2.)
1-5
SUPERSERVER 5014C-MF User's Manual
Cooling System
The SC513L-260 chassis has an innovative cooling design that features one 10-cm
blower-type system cooling fan. The blower fan plugs into a chassis fan header
on the motherboard and an air shroud channels the airflow to efficiently cool the
processor area.
A fan speed control setting in BIOS allows fan speed to be determined by system
temperature [the recommended setting is 3-pn (Server)], see page 7-11.
Figure 1-2. Front I/O Panel
1-6
Chapter 1: Introduction
1-4
Contacting Supermicro
Headquarters
Address:
Tel:
Fax:
Email:
Web Site:
SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
+1 (408) 503-8000
+1 (408) 503-8008
[email protected] (General Information)
[email protected] (Technical Support)
www.supermicro.com
Europe
Address:
Tel:
Fax:
Email:
SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
+31 (0) 73-6400390
+31 (0) 73-6416525
[email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Pacific
Address:
SuperMicro, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C.
Tel:
+886-(2) 8226-3990
Fax:
+886-(2) 8226-3991
Web Site:
www.supermicro.com.tw
Technical Support:
Email:
[email protected]
Tel:
886-2-8228-1366, ext.132 or 139
1-7
SUPERSERVER 5014C-MF User's Manual
Notes
1-8
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 5014C-MF
up and running. Following the steps in the order given should enable you to have
the system operational within a minimal amount of time. This quick setup assumes
that your 5014C-MF system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a motherboard, processor,
system memory etc., please turn to the chapter or section noted in each step for
details on installing specific components.
2-2
Unpacking the System
You should inspect the box the SuperServer 5014C-MF was shipped in and note
if it was damaged in any way. If the server itself shows damage, you should file a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 5014CMF. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fields are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3
Preparing for Setup
The SuperServer 5014C-MF does not ship with a rack rail hardware package as the
system can be rack mounted without the use of rails. An optional rack rail package
is available if you wish to order from Supermicro. Follow the steps in the order
given to complete the installation process in a minimal amount of time. Please
read this section in its entirety before you begin the installation procedure outlined
in the sections that follow.
2-1
SUPERSERVER 5014C-MF User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow for
sufficient airflow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
Warnings and Precautions!
!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
floor with the full weight of the rack resting on them.
- In a single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack first, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
- Allow the power supply units and hot plug Serial ATA drives to cool before touching them.
- Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
SUPERSERVER 5014C-MF User's Manual
2-4
Installing the System into a Rack
This section provides information on installing the SuperServer 5014C-MF into a
rack unit. If the system has already been mounted into a rack, you can skip ahead
to Sections 2-5 and 2-6.
Basic Installation Procedure
The 5014C-MF server comes with two rack mounting brackets, which are located
on each side at the front of the chassis. To mount the system into a rack, simply
screw these brackets directly to the front of the rack (two screws for each bracket).
You may also detach the brackets from the chassis and move them back approx.
4 inches, where you will see a group of three holes to secure them to. You may
then secure them to the rack as just described. Note that installing in this manner
may prevent you from closing the rack door.
Installing with Optional Rackmount Kit (CSE-PT8)
This section is only for customers that have the optional rack mount kit.. Each of
these assemblies consist of two sections: an inner rail that secures to the chassis
and an outer rail that secures directly to the rack itself (see Figure 2-1). This is
a guideline for installing the unit into a rack with the optional rack kit. You should
Figure 2-1. Identifying the Rail Sections
Outer (rack) rail
Inner (chassis) rail
2-4
Chapter 2: Server Installation
also refer to the installation instructions that came with the rack unit you are using.
Be aware that there are a variety of rack units on the market, which may mean the
assembly procedure will differ slightly.
The two rail sections must be detached from each other prior to installation. Do
this by depressing the locking tab on the inner rail to release it from its locked
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of the
chassis so that the three screw holes line up with the corresponding holes on the
chassis. Note that these two rails are left/right specific. Screw the rail securely to
the side of the chassis (see Figure 2-2) with the screws provided in the rackmount
kit. Repeat this procedure for the other rail on the other side of the chassis. You
will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which
serves two functions. The first is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
2-5
SUPERSERVER 5014C-MF User's Manual
Installing the Rack Rails
Locate a pair of front (short) and rear (long) brackets in the rackmount kit. The
brackets are marked with arrows to distinguish front from rear. Secure the front
and rear brackets to the rack rails using the screws and washers provided, but do
not fully tighten. Determine where you want to place the SuperServer 5014C-MF
in the rack (see Rack and Server Precautions in Section 2-3). Adjust the length
of the rails according to the depth of the rack. Now tighten the screws holding the
brackets to the rails.
Next, secure the rail to the rack with the screws provided. Repeat this procedure
to attach the other rail to the other side of the rack, making sure that both are at
the exact same height.
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). The server may not slide in easily when installed for the first time; some
adjustment to the rails might be necessary. See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
When removing the server from a rack, you will need to release the locking tabs
on both rails to pull the unit completely out of the rack.
2-6
Chapter 2: Server Installation
Figure 2-3. Installing the Server into a Rack
Installing the Server into a Telco Rack
If you are installing the SuperServer 5014C-MF into a Telco type rack, follow the
directions given on the previous pages for rack installation. The only difference in
the installation procedure will be the positioning of the rack brackets to the rack.
They should be spaced apart just enough to accomodate the width of the telco
rack. See Figure 2-4.
2-7
SUPERSERVER 5014C-MF User's Manual
Figure 2-4.
Installing the Server into a Telco Rack
2-8
Chapter 2: Server Installation
2-5 Checking the Motherboard Setup
After you install the 5014C-MF in the rack, you will need to open the unit to make
sure the motherboard is properly installed and all the connections have been
made.
1. Accessing the inside of the system (Figure 2-5)
First, release the retention screws that secure the unit to the rack. If you installed
with rails, grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click"). Next, remove the screw at the back of the chassis
that secures the top cover. Depress the two buttons on the top of the chassis to
release the top cover from the locked position. Push the cover away from you until
it stops. You can then lift the top cover from the chassis to gain full access to the
inside of the server.
2. Check the CPU (processor)
You may have one processor already installed into the system board. The processor
should have its own heatsink attached. See Chapter 5 for instructions on processor
installation.
3. Check the system memory
Your 5014C-MF server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
4. Installing add-on cards
If desired, you can install an add-on card to the system. See Chapter 5 for details
on installing a PCI add-on card.
5. Check all cable connections and airflow
Make sure all power and data cables are properly connected and not blocking the
airflow. See Chapter 5 for details on cable connections. Also, check the air seals
for damage. The air seals are located under the blower fan and beneath the frame
cross section that separates the drive bay area from the motherboard area of the
chassis.
2-9
SUPERSERVER 5014C-MF User's Manual
Figure 2-5. Accessing the Inside of the System
2-10
Chapter 2: Server Installation
2-6
Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the Serial ATA drives
and Serial ATA backplane have been properly installed and all essential connections
have been made.
1. Accessing the drive bays
To access the internal hard drives, you will need to remove the top chassis cover.
See step 1 in the previous section for instructions on removing the top chassis
cover.
2. Check the hard disk drive
Depending upon your system's configuration, your system may have an IDE or
Serial ATA drive already installed. If you need to install an IDE or Serial ATA drive,
please refer to the appropriate section in Chapter 6.
3. Check the airflow
Airflow is provided by a single 10-cm blower fan. The system component layout
was carefully designed to promote sufficient airflow through the small 1U rackmount
space. Also note that all power and data cables have been routed in such a way
that they do not block the airflow generated by the fans.
4. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the power
cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an
uninterruptible power supply (UPS).
2-11
SUPERSERVER 5014C-MF User's Manual
Notes
2-12
Chapter 3: System Interface
Chapter 3
System Interface
3-1
Overview
There are several LEDs on the control panel to keep you constantly informed of
the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel. This chapter
explains the meanings of all LED indicators and the appropriate response you may
need to take.
3-2
Control Panel Buttons
There are two push-button buttons located on the front of the chassis. These are
(in order from left to right) a reset button and a power on/off button.
RESET: The reset switch reboots the system.
POWER: This is the main power switch, which is used to apply or turn off
the main system power. Turning off system power with this button removes the
main power but keeps standby power supplied to the system.
3-1
SUPERSERVER 5014C-MF User's Manual
3-3
Control Panel LEDs
The control panel located on the front of the chassis has five LEDs. These LEDs
provide you with critical information related to different parts of the system. This
section explains what each LED indicates when illuminated and any corrective action you may need to take.
Overheat/Fan Fail: When this LED flashes, it indicates a fan failure. When
on continuously it indicates an overheat condition, which may be caused by cables
obstructing the airflow in the system or the ambient room temperature being too
warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain flashing or on as long as the indicated condition exists.
2
NIC2: Indicates network activity on GLAN2 when flashing .
1
NIC1: Indicates network activity on GLAN1 when flashing.
HDD: Channel activity for all hard disk drives. This light indicates SATA drive
activity when flashing.
3-2
Chapter 3: System Interface
Power: Indicates power is being supplied to the system's power supply unit.
This LED should normally be illuminated when the system is operating.
3-3
SUPERSERVER 5014C-MF User's Manual
Notes
3-4
Chapter 4: System Safety
Chapter 4
System Safety
4-1
Electrical Safety Precautions
!
Basic electrical safety precautions should be followed to protect yourself from harm
and the SuperServer 5014C-MF from damage:
Be aware of the locations of the power on/off switch on the chassis as well as
the room's emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power
from the system.
Do not work alone when working with high voltage components.
Power should always be disconnected from the system when removing or
installing main system components, such as the motherboard, memory
modules and floppy drives. When disconnecting power, you should first
power down the system with the operating system first and then unplug the
power cords of all the power supply units in the system.
When working around exposed electrical circuits, another person who is
familiar with the power-off controls should be nearby to switch off the power
if necessary.
Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock.
Use extreme caution when using metal tools, which can easily damage any
electrical components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection
from electrical shock. Instead, use rubber mats that have been specifically
designed as electrical insulators.
The power supply power cords must include a grounding plug and must be
plugged into grounded electrical outlets.
4-1
SUPERSERVER 5014C-MF User's Manual
Motherboard Battery: CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarites (see Figure
4-1). The battery must be replaced with the same or an equivalent type
recommended by the manufacturer. Dispose of used batteries according to
manufacturer's instructions.
CD-ROM Laser: CAUTION - this server may have come equipped with a CDROM drive. To prevent direct exposure to the laser beam and hazardous
radiation exposure, do not open the enclosure or use the unit in any
unconventional way.
4-2
General Safety Precautions
!
Follow these rules to ensure general safety:
Keep the area around the SuperServer 5014C-MF clean and free of clutter.
The SuperServer 5014C-MF weighs approximately 16.5 lbs (7.5 kg) when fully
loaded. When lifting the system, two people at either end should lift slowly
with their feet spread out to distribute the weight. Always keep your back
straight and lift with your legs.
Place the chassis top cover and any system components that have been
removed away from the system or on a table so that they won't accidentally
be stepped on.
While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits
or be pulled into a cooling fan.
Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into
contact with printed circuit boards or areas where power is present.
After accessing the inside of the system, close the system back up and secure
it to the rack unit with the retention screws after ensuring that all connections
have been made.
4-2
Chapter 4: System Safety
4-3
ESD Precautions
!
Electrostatic discharge (ESD) is generated by two objects with different electrical
charges coming into contact with each other. An electrical discharge is created to
neutralize this difference, which can damage electronic components and printed
circuit boards. The following measures are generally sufficient to neutralize this
difference before contact is made to protect your equipment from ESD:
Use a grounded wrist strap designed to prevent static discharge.
Keep all components and printed circuit boards (PCBs) in their antistatic
bags until ready for use.
Touch a grounded metal object before removing the board from the antistatic
bag.
Do not let components or PCBs come into contact with your clothing, which
may retain a charge even if you are wearing a wrist strap.
Handle a board by its edges only; do not touch its components, peripheral
chips, memory modules or contacts.
When handling chips or modules, avoid touching their pins.
Put the motherboard and peripherals back into their antistatic bags when
not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
4-3
SUPERSERVER 5014C-MF User's Manual
4-4
Operating Precautions
!
Care must be taken to assure that the chassis cover is in place when the
5014C-MF is operating to assure proper cooling. Out of warranty damage to
the 5014C-MF system can occur if this practice is not strictly followed.
Figure 4-1. Installing the Onboard Battery
LITHIUM BATTERY
LITHIUM BATTERY
OR
BATTERY HOLDER
BATTERY HOLDER
4-4
Chapter 5: Advanced Motherboard Setup
Chapter 5
Advanced Motherboard Setup
This chapter covers the steps required to install the P8SCT motherboard into the
SC513L-260 chassis, connect the data and power cables and install add-on cards.
All motherboard jumpers and connections are also described. A layout and quick
reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have finished working with the motherboard to
better cool and protect the system.
5-1
Handling the Motherboard
Electric-static discharge (ESD) can damage electronic components. To prevent
damage to any printed circuit boards (PCBs), it is important to handle them very
carefully (see previous chapter). To prevent the P8SCT motherboard from bending, keep one hand under the center of the board to support it when handling. The
following measures are generally sufficient to protect your equipment from electric
static discharge.
Precautions
•
Use a grounded wrist strap designed to prevent Electric Static Discharge
(ESD).
•
Touch a grounded metal object before removing any board from its antistatic
bag.
• Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
•
When handling chips or modules, avoid touching their pins.
•
Put the motherboard, add-on cards and peripherals back into their antistatic bags
when not in use.
•
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
5-1
SUPERSERVER 5014C-MF User's Manual
Unpacking
The motherboard is shipped in antistatic packaging to avoid electrical static discharge. When unpacking the board, make sure the person handling it is static
protected.
5-2
Motherboard Installation
This section explains the first step of physically mounting the P8SCT into the
SC513L-260 chassis. Following the steps in the order given will eliminate the most
common problems encountered in such an installation. To remove the motherboard,
follow the procedure in reverse order.
1. Accessing the inside of the system (see Figure 2-5)
Two release buttons are located on the top cover of the chassis. Depressing both
of these buttons while pushing the cover away from you until it stops. You can then
lift the top cover from the chassis to gain full access to the inside of the server. (If
already installed in a rack, you must first release the retention screws that secure
the unit to the rack. Then grasp the two handles on either side and pull the unit
straight out until the rails lock into place.)
2. Check compatibility of motherboard ports and I/O shield
The P8SCT requires a chassis big enough to support a 12" x 9.5" motherboard,
such as Supermicro's SC513L-260 1U rackmount. Make sure that the I/O ports
on the motherboard align properly with their respective holes in the I/O shield at
the back of the chassis.
3. Mounting the motherboard onto the motherboard tray
Carefully mount the motherboard to the motherboard tray by aligning the board
holes with the raised metal standoffs that are visible in the chassis. Insert screws
into all the mounting holes on your motherboard that line up with the standoffs
and tighten until snug (if you screw them in too tight, you might strip the threads).
Metal screws provide an electrical contact to the motherboard ground to provide a
continuous ground for the system.
5-2
Chapter 5: Advanced Motherboard Setup
5-3
Connecting Cables
Now that the motherboard is installed, the next step is to connect the cables to
the board. These include the data (ribbon) cables for the peripherals and control
panel and the power cables.
Connecting Data Cables
The ribbon cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the flow of cooling air that moves through
the system from front to back. If you need to disconnect any of these cables, you
should take care to keep them routed as they were originally after reconnecting
them (make sure the red wires connect to the pin 1 locations). The following data
cables (with their locations noted) should be connected. (See the layout on page
5-9 for connector locations.) Note that you may install either a single IDE drive or
a single Serial ATA drive.
Control Panel cable (JF1)
IDE drive cable (IDE) or Serial ATA cable (SATA#0)
Connecting Power Cables
The P8SCT has a 24-pin primary power supply connector (PW1) for connection
to the ATX power supply. In addition, there is a 4-pin secondary power connector
(PW2) that also must be connected to your power supply. See Section 5-9 for
power connector pin definitions.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1
for the pin locations of the various front control panel buttons and LED indicators.
All JF1 wires have been bundled into a single ribbon cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the board. The other
end connects to the Control Panel PCB board, located just behind the system status
LEDs on the chassis. See Chapter 5 for details and pin descriptions.
5-3
SUPERSERVER 5014C-MF User's Manual
Figure 5-1. Control Panel Header Pins
20
19
Ground
NMI
x (Key)
x (Key)
Power On LED
Vcc 5V Stby
IDE/SATA LED
Vcc 3V
NIC1 LED
Vcc 3V Stby
NIC2 LED
Vcc 3V Stby
OH/Fan Fail LED
Vcc 3V
Reserved
Reserved
Ground
Reset (Button)
Ground
Power (Button)
2
5-4
1
I/O Ports
The I/O ports are color coded in conformance with the PC 99 specification. See
Figure 5-2 below for the colors and locations of the various I/O ports, all are located
at the front of the chassis.
Figure 5-2. I/O Ports
Mouse (Green)
Keyboard
Parallel Port (Burgundy)
USB 0/1 Ports COM1 Port (Turquoise)
VGA Port (Blue)
JLAN1
JLAN2
(Purple)
Note: The COM2 port is a header on the motherboard, located near the PCI #1
slot at the corner of the motherboard.
5-4
Chapter 5: Advanced Motherboard Setup
5-5
Installing the Processor
Avoid placing direct pressure to the top of the processor
!
package. Always remove the power cord first before adding,
removing or changing any hardware components.
Processor Support
The P8SCT has a single LGA775 socket, which supports Intel Pentium 4 (800 MHz
FSB) or Intel Celeron (533 MHz FSB) processors.
CPU socket (with load plate)
Step 1.
1. Press the socket lever to release the
load plate that covers the CPU socket
from its locking position.
Socket Lever
Load Plate
Step 2a.
2. Carefully lift the socket lever up to
open the load plate.
Step 2b.
Load Plate
North Key
Step 3.
3. Locate Pin 1 on the CPU socket. (Pin
1 is closest to the notched corner of the
housing.) Please note that a North key
and a South key (notches) are located
at opposite sides of the CPU housing.
Pin 1
Notched
corner
South Key
5-5
SUPERSERVER 5014C-MF User's Manual
North Center Edge
Step 4.
4. Use your thumb and index finger to
hold the CPU at the north center and
south center edges of the CPU.
5. Align Pin 1 of the CPU with Pin 1
of the socket. Once aligned, carefully
South Center Edge
lower the CPU straight down and into
the socket. Do not drop the CPU on
the socket. Do not move the CPU
horizontally or vertically. Do not rub
the CPU against the surface of the
socket or against any pins of the socket,
which may damage the CPU and/or
the socket.
Steps 5 & 6.
Socket Lever
CPU in the CPU socket
6. With the CPU inside the socket,
inspect the four corners of the CPU
to make sure that the CPU is properly
installed.
Step 7.
7. Use your thumb to gently press the
lever down and lock it in the hook.
Step 8.
8. If the CPU is properly installed into
the socket, the black plastic cover will
be automatically released from the load
plate when the lever is pushed into
the hook. Remove the cover from the
motherboard.
Plastic cap is released from
the load plate when the CPU is
properly installed.
5-6
Chapter 5: Advanced Motherboard Setup
Heatsink Installation
1. Do not apply any thermal grease to
the heatsink or the CPU die; the required
amount has already been applied.
2. Place the heatsink on top of the CPU so
that the four mounting holes are aligned with
those on the retention mechanism.
3. Screw in two diagonal screws (eg. the #1
and the #2 screws) until just snug (do not
fully tighten the screws, which may damage
the CPU).
4. Finish the installation by fully tightening
all four screws.
Retention mechanism (pre-installed)
Heatsink Removal
1. Unscrew and remove the heatsink screws
from in the sequence as show in the picture
on the right.
2. Hold and gently wriggle the heatsink to
loosen it from the CPU. (Do not use excessive force when loosening the heatsink!)
3. Once the heatsink is loosened, remove it
from the CPU socket.
4. Clean the surfaces of the CPU and the
heatsink to remove the old thermal grease.
Reapply the proper amount of thermal
grease on the surface before re-installing
the heatsink.
5-7
SUPERSERVER 5014C-MF User's Manual
5-6
Installing Memory
CAUTION! Exercise extreme care when installing or removing
!
DIMM modules to prevent any possible damage.
1. Memory support
The P8SCT supports up to 4 GB of dual or single-channel, unbuffered ECC or
unbuffered non-ECC DDR2-533 or DDR2-400 SDRAM. Both interleaved and noninterleaved memory are supported, so you may populate any number of DIMM slots.
Populating two slots at a time (starting with Bank 1: DIMM1A and DIMM 1B) with
the same size and type of memory modules will result in dual-channel (two-way
interleaved) operation, which is faster than single channel operation.
2. Installing memory modules
Insert each memory module vertically. Pay attention to the notches along the bottom
of the module to prevent inserting it incorrectly. Gently press down on the DIMM
module until it snaps into place in the slot (see Figure 5-3).
Figure 5-3. DIMM Installation
Notch
Release
Tab
Notch
Note: Notches
should align
with their
receptive points
on the slot
Release
Tab
To Install: Insert module vertically and press down until it snaps into place. Pay attention to the bottom
notches.
To Remove: Use your thumbs to gently push each release tab outward to free the DIMM from the
slot.
5-8
Chapter 5: Advanced Motherboard Setup
5-7
Adding PCI Cards
1. 64-bit PCI-X slot
The 5014C-MT has a riser card (p/n CSE-RR1U-X) designed specifically for use
in the SC513L-260 1U rackmount chassis (included with the system). This riser
card allows a 64-bit, 133 MHz (3.3V) standard size PCI-X card to sit at a 90 degree
angle so it can fit inside the chassis.
2. PCI card installation
The riser card has already been preinstalled into the motherboard. Perforn the
following steps to add a PCI add-on card:
1. Remove the appropriate PCI slot shield by releasing the locking tab.
2. Insert the add-on card into the riser card.
3. Secure the add-on card with the locking tab.
5-9
SUPERSERVER 5014C-MF User's Manual
5-8
Motherboard Details
Figure 5-4. P8SCT Layout
(not drawn to scale)
Kybd/Mouse
JPWAKE1
JPUSB1
J14
Keyboard/
Mouse
FAN1
FAN5
ATX Power Connector
PW2
JFSB2/JFSB1
PW1
+12V PWR
USB1/2
COM1
CPU
Parallel Port
E7221
LGA775
North Bridge
J11
VGA
BANK1
JLAN1
DIMM1A
DIMM1B
JLAN2
BANK2
DIMM2B
SPEAKER
PXH-V
JF1
SUPER
PCI-X #6 (133 MHz)
J9
JSLED
P8SCT
DIMM2A
JP3
BATTERY
FAN2
PCI #5 (33 MHz)
ICH6R
PCI #5 (33 MHz)
BIOS
FAN3
South Bridge
SATA#0 / SATA#1 / SATA#2 / SATA#3
BCM5721
PCI #4 (33 MHz)
JPL1
JPL2
PCI #3 (33 MHz)
LE1
PCI #2 (33 MHz)
IPMI
JP1
JP2
JPUSB2
PCI #1 (33 MHz)
JWD
JK1
JWOR
JWOL
COM2
USB5/6
USB3/4
Floppy
Note: Jumpers not indicated are for test purposes only.
5-10
JL1
JPF
JLED
BCM5721
FAN4
IDE
Chapter 5: Advanced Motherboard Setup
P8SCT Quick Reference
Jumper
Description
Default Setting
JBT1
CMOS Clear
See Section 5-10
JP1/JP2
SMBus to PCI Enable/Disable
Open (Disabled)
JP3
JPF
PCI-X Slot Frequency
Power Force-On
Closed (133 MHz)
Open (Disabled)
JPL1/JPL2
JLAN1/JLAN2 Enable/Disable
Pins 1-2 (Enabled)
JFSB1/JFSB2 CPU Frequency Speed
Pins 1-2 (Auto)
JPUSB1/2
JPWAKE1
JWD
Pins 2-3 (Disabled)
Pins 1-2 (Enabled)
Pins 1-2 (Reset)
USB1/2 & USB3/4/5/6 Wakeup
Keyboard/Mouse Wakeup En/Disable
Watchdog
Connector
Description
COM1/COM2
Fan1-5
Floppy
IDE
IPMI
J9
J11
J14
JF1
JK1
JL1
JLAN1/2
JOH1
JSLED
JWOL
JWOR
LE1
PW1
PW2
SATA#0 - #3
USB1/2
USB3/4/5/6
VGA
COM1/COM2 Serial Port Connectors
System Fan Headers
Floppy Disk Drive Connector
IDE Hard Disk Drive Connector
IPMI 2.0 Header
Internal Speaker (Buzzer) Header
Parallel (Printer) Port
Keyboard/Mouse Ports
Front Control Panel Connector
Keylock Header
Chassis Intrusion Header
Gigabit Ethernet Ports
Overheat LED Header
SATA LED Header
Wake-on-LAN Header
Wake-on-Ring Header
+5V Standby Voltage Warning LED
24-pin ATX Power Connector
4-pin (12V) ATX Power Connector
ICH6R Serial ATA Connectors
Universal Serial Bus Ports
Universal Serial Bus Headers
VGA (Monitor) Port
5-11
SUPERSERVER 5014C-MF User's Manual
5-9
Connector
Definitions
ATX Power 24-pin Connector
Pin Definitions (PW1)
Pin#
Definition
13
+3.3V
1
+3.3V
14
-12V
2
+3.3V
15
COM
3
COM
16
PS_ON
4
+5V
17
COM
5
COM
18
COM
6
+5V
pin definitions of the ATX 24-pin power
19
COM
7
COM
connector. You must also connect the
20
Res (NC)
8
PWR_OK
4-pin (PSW2) processor power connector to your power supply. Refer
to the table below right for the PW2
(12V) connector.
21
+5V
9
5VSB
22
+5V
10
+12V
23
+5V
11
+12V
24
COM
12
+3.3V
Power Supply Connectors
The primary power supply connector
(PW1) on the P8SCT meets the SSI
(Superset ATX) 24-pin specification.
Refer to the table on the right for the
Important: you must connect PW2 to
your power supply to meet the ATX
safety requirements.
Pin #
Definition
+12V 4-pin Power
Pin Definitions (PW2)
Required Connection
PW_ON Connector
Pins
Definition
1&2
Ground
3&4
+12V
Power Button
Pin Definitions (JF1)
The PW_ON connector is on pins 1
and 2 of JF1. This header should
be connected to the chassis power
button. See the table on the right for
pin definitions.
Reset Connector
Pin#
Definition
1
PW_ON
2
Ground
Reset Button
Pin Definitions (JF1)
The reset connector is located on pins
3 and 4 of JF1 and attaches to the
reset switch on the computer chassis. See the table on the right for pin
definitions.
5-12
Pin#
Definition
3
Reset
4
Ground
Chapter 5: Advanced Motherboard Setup
Overheat LED (OH)
OH/Fan Fail LED
Pin Definitions (JF1)
Connect an LED to the OH connection
Pin#
Definition
on pins 7 and 8 of JF1 to provide ad-
7
Vcc
vanced warning of chassis overheating. Refer to the table on the right for
8
Ground
pin definitions.
NIC2 (JLAN2) LED
NIC2 LED
Pin Definitions (JF1)
The LED connections for JLAN2 are
on pins 9 and 10 of JF1. Attach LAN
LED cables to display network activity. See the table on the right for pin
definitions.
NIC1 (JLAN1) LED
Pin#
Definition
9
Vcc
10
Ground
NIC1 LED
Pin Definitions (JF1)
The LED connections for JLAN1 are
on pins 11 and 12 of JF1. Attach LAN
LED cables to display network activity. See the table on the right for pin
definitions.
IDE/SATA LED
Pin#
Definition
11
Vcc
12
Ground
IDE/SATA LED
Pin Definitions (JF1)
The IDE/SATA LED connection is located on pins 13 and 14 of JF1. This
LED is used to display all IDE and
SATA activity. See the table on the
right for pin definitions.
5-13
Pin#
Definition
13
Vcc
14
HD Active
SUPERSERVER 5014C-MF User's Manual
Power On LED
Power LED
Pin Definitions (JF1)
The Power On LED connector is lo-
Pin#
Definition
cated on pins 15 and 16 of JF1 (use
15
5V Stby
JLED for a 3-pin connector). This
connection is used to provide LED
16
Control
indication of power being supplied to
the system. See the table on the right
for pin definitions.
NMI Button
NMI Button
Pin Definitions (JF1)
The non-maskable interrupt button
header is located on pins 19 and 20
of JF1. Refer to the table on the right
for pin definitions.
Pin#
Definition
19
Control
20
Ground
Fan Headers
Fan Header
Pin Definitions
(Fan1-5)
There are five fan headers on the
P8SCT, which are designated FAN1,
FAN2, FAN3, FAN4 and FAN5. Connect the fan on your CPU heatsink to
the FAN1 header. See the table on
the right for pin definitions.
Pin#
Definition
1
Ground (Black)
2
+12V (Red)
3
Tachometer
4
PWM Control
ATX PS/2 Keyboard and
PS/2 Mouse Ports
PS/2 Keyboard and
Mouse Port Pin
Definitions (J14)
The ATX PS/2 keyboard and the
PS/2 mouse are located on J14. The
mouse port is above the keyboard
port. See the table on the right for
pin definitions.
5-14
Pin#
Definition
1
Data
2
NC
3
Ground
4
VCC
5
Clock
6
NC
Chapter 5: Advanced Motherboard Setup
Chassis Intrusion
Chassis Intrusion
Pin Definitions (JL1)
The Chassis Intrusion header is des-
Pin#
Definition
ignated JL1. See the board layout for
1
Intrusion Input
the location of JL1 and the table on
the right for pin definitions.
2
Ground
Universal Serial Bus (USB)
Universal Serial Bus
Pin Definitions (USB0/1)
There are two Universal Serial Bus
ports located on the I/O panel and
four additional USB headers located
on the motherboard. The headers,
labeled USB3/4 and USB5/6, can be
used to provide front side USB access
(cables not included). See the tables
on the right for pin definitions.
USB0/1/3/5
Pin #
Definition
USB4/6
Pin #
Definition
1
+5V
1
+5V
2
PO-
2
PO-
3
PO+
3
PO+
4
Ground
4
Ground
5
N/A
5
Key
Wake-On-LAN
Wake-On-LAN
Pin Definitions
(JWOL)
The Wake-On-LAN header is designated JWOL on the motherboard.
See the table on the right for pin
definitions. You must enable the LAN
Wake-Up setting in BIOS to use this
function. (You must also have a LAN
card with a Wake-On-LAN connector
and cable to use this feature.)
JLAN1/2 (Ethernet Ports)
Two Ethernet ports (designated
JLAN1 and JLAN2) are located
beside the VGA port on the I/O
backplane. These ports accept
RJ45 type cables.
5-15
Pin#
Definition
1
+5V Standby
2
Ground
3
Wake-up
SUPERSERVER 5014C-MF User's Manual
Wake-On-Ring
Wake-On-Ring
Pin Definitions
(JWOR)
The Wake-On-Ring header is designated
JWOR. This function allows your computer
to receive and be "awakened" by an incoming call when in the suspend state. See the
Pin#
Definition
1
Ground (Black)
2
Wake-up
table on the right for pin definitions. You
must also have a WOR card and cable to
use this feature.
SATA LED
SATA LED Pin
Definitions (JSLED)
The SATA LED header is designated
JSLED. This header is used to display
all SATA activity. See the table on the
right for pin definitions.
Serial Ports
Pin#
Definition
1
HD Active
2
HD Active
3
HD Active
4
HD Active
5
NC
Serial Port Pin Definitions
(COM1/COM2)
Two serial ports are included on the
motherboard: COM1 is a port located
under the parallel port and COM2 is
a header located on the motherboard
near the floppy connector. See the
table on the right for pin definitions.
Pin #
Definition
Pin #
Definition
1
DCD
6
DSR
2
RXD
7
RTS
3
TXD
8
CTS
4
DTR
9
RI
5
Ground
10
NC
Note: Pin 10 is included on the header but not on
the port. NC indicates no connection.
Power LED
The Power LED header is located on
JLED. This header provides LED indication of power being supplied to the
system. See the table on the right for
pin definitions.
5-16
Power LED
Pin Definitions
(JLED)
Pin#
Definition
1
Anode
2
Key
3
Cathode
Chapter 5: Advanced Motherboard Setup
5-10 Jumper Settings
Explanation of
Jumpers
To modify the operation of the mother-
3
2
1
3
2
1
Connector
Pins
board, jumpers can be used to choose
between optional settings. Jumpers
create shorts between two pins to
Jumper
change the function of the connector.
Pin 1 is identified with a square solder
pad on the printed circuit board. See
the motherboard layout pages for
jumper locations.
Setting
Note: On a two-pin jumper, "Closed"
means the jumper is on both pins and
"Open" means the jumper is either on
only one pin or completely removed.
CMOS Clear
JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins,
this jumper consists of contact pads to prevent accidentally clearing the contents
of CMOS. To clear CMOS,
1) First power down the system and unplug the power cord(s)
2) With the power disconnected, short the CMOS pads with a metal object such
as a small screwdriver
3) Remove the screwdriver (or shorting device)
4) Reconnect the power cord(s) and power on the system.
Speaker Connector
Speaker Jumper
Pin Definitions (J9)
Use the header on J9 to enable either
the internal or an external speaker. To
use the internal system speaker, connect the speaker wires to pins 3-4. If
you wish to use an external speaker,
you should jump pins 1 and 2.
5-17
Setting
Definition
Pins 1-2
External Speaker
Pins 3-4
Internal Speaker
SUPERSERVER 5014C-MF User's Manual
USB Wake-Up
Use JPUSB1/2 to enable or disable
USB Wake-Up
Jumper Settings
(JPUSB1/2)
USB Wake-Up, which allows you to
Jumper Setting
wakeup the system by depressing a
key on the keyboard or by clicking the
Pins 1-2
Enabled
Pins 2-3
Disabled
Definition
mouse when either is connected to a
USB port. Enable the jumper to allow
the system to be woken up from an
S1 or S3 state in Windows OS. The
JPUSB1 jumper controls the USB1/2
ports and the JPUSB2 jumper controls
the USB2/3 and USB4/5 headers.
See the table on the right for jumper
settings.
Keyboard Wake-Up
The JPWAKE1 jumper is used to allow the system to be woken up by
depressing a key on the keyboard
from an S1 or S3 state in Windows
OS. See the table on the right for
jumper settings. Your power supply
must meet ATX specification 2.01 or
higher and supply 720 mA of standby
power to use this feature.
System Power Force On
Jumper JPF allows you to enable or
disable the Force-Power-On function.
If enabled, system power will always
stay on. If disabled (the normal setting), the user needs to press the power
button to power on the system.
5-18
Keyboard Wake-Up
Jumper Settings
(JPWAKE1)
Jumper Setting
Definition
Pins 1-2
Disabled
Pins 2-3
Enabled
System Power Force On
Jumper Settings
(JPF)
Jumper Setting
Definition
Closed
Force On
Open
Disabled
Chapter 5: Advanced Motherboard Setup
Watch Dog Enable/Disable
Watch Dog
Jumper Settings (JWD)
JWD enables the Watch Dog function,
Jumper Setting
a system monitor that takes action
Pins 1-2
Reset
when a software application freezes
the system. Jumping pins 1-2 will
Pins 2-3
NMI
Open
Disabled
Definition
have WD reboot the system if a pro-
Note: when Watch Dog is enabled, the user must
gram freezes. Jumping pins 2-3 will
write their own application software to disable the
generate a non-maskable interrupt for
Watch Dog Timer.
the program that has frozen. See the
table on the right for jumper settings.
Watch Dog must also be enabled in
BIOS.
JLAN1/JLAN2 Enable/
Disable
JLAN1/2 Enable/Disable
Jumper Settings (JPL1/2)
Change the setting of jumper JPL1 to
enable or disable the JLAN1 port and
JPL2 to enable or disable the JLAN2
port on the motherboard. See the
table on the right for jumper settings.
The default setting is enabled.
SMBus to PCI
Jumpers JP1, JP2 allow you to connect PCI/PCI-X slots to the System
Management Bus. The default setting
is “Open” to disable the connection.
See the table on the right for jumper
settings.
5-19
Jumper Setting
Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
SMBus to PCI
Enable/Disable
Jumper Settings (JP1/JP2)
Jumper Setting
Definition
Closed
Enabled
Open
Disabled
SUPERSERVER 5014C-MF User's Manual
PCI-X Slot Speed Select
PCI-X Slot Speed Select
Jumper Settings (JP3)
JP3 allows you to select the Frequency
Jumper Setting
for the PCI-X slot. The default setting
is Closed. (Please do not change the
default setting.) See the table on the
Definition
Open
133 MHz
Closed
100 MHz
right for pin definitions.
CPU Front Side Bus Speed
JFSB1 and JFSB2
CPU Front Side Bus Speed
Pin Definitions
(JFSB1/JFSB2)
allow you to set
the Front Side Bus Frequency. See
the table on the right for pin definitions.
(The default setting is Auto and should
not be changed.)
JFSB1
JFSB2
Definition
Pins 1-2
Pins 1-2
Auto
Pins 2-3
Pins 2-3
266 MHz
Pins 2-3
Open
200 MHz
Open
Open
166 MHz
Open
Pins 2-3
133 MHz
Note: Clock values are shown, employ a 4x
multiplier for front side bus speed. This jumper
setting should remain on Auto.
5-11 Onboard Indicators
JLAN Right LED
Connection Speed Indicator
JLAN1/JLAN2 LEDs
The Ethernet ports (located beside
the VGA port) have two LEDs. On
each Gb LAN port, the yellow (right)
LED indicates activity while the left
LED may be green, orange or off to
indicate the speed of the connection.
See the table on the right for the functions associated with the left (activity
speed) LED.
5-20
LED Color
Definition
Off
10 MHz
Green
100 MHz
Amber
1 GHz
Chapter 5: Advanced Motherboard Setup
5-12 Parallel Port, Floppy and IDE Drive Connections
Use the following information to connect the IDE hard disk drive cables.
•
A red mark on a wire typically designates the location of pin 1.
• The 80-wire ATA100/66 IDE hard disk drive cable that came with your system
has two connectors to support two drives. This special cable should be used
to take advantage of the speed this new technology offers. The blue connector
connects to the onboard IDE connector interface and the other connector(s) to
your hard drive(s). Consult the documentation that came with your disk drive
for details on actual jumper locations and settings for the hard disk drive.
Parallel (Printer) Port Connector
Pin Definitions (J11)
Parallel Port Connector
The parallel port is located on
J11. See the table at right for pin
definitions.
Pin#
Definition
1
Strobe-
2
Auto Feed-
3
Data Bit 0
4
Error-
5
Data Bit 1
6
Init-
7
Data Bit 2
8
SLCT IN-
9
Data Bit 3
10
GND
11
Data Bit 4
12
GND
13
Data Bit 5
14
GND
15
Data Bit 6
16
GND
17
Data Bit 7
18
GND
19
ACK
20
GND
21
BUSY
22
Write Data
23
PE
24
Write Gate
25
SLCT
26
NC
5-21
Pin #
Definition
SUPERSERVER 5014C-MF User's Manual
Floppy Connector
The floppy connector is located
between the IDE slot and the
IPMI Socket. See the table below
for pin definitions.
Floppy Drive Connector
Pin Definitions (Floppy)
Pin#
Definition
1
Ground
2
FDHDIN
3
Ground
4
Reserved
5
Key
6
FDEDIN
7
Ground
8
Index
9
Ground
10
Motor Enable
11
Ground
12
Drive Select B
13
Ground
14
Drive Select B
15
Ground
16
Motor Enable
17
Ground
18
DIR
19
Ground
20
STEP
21
Ground
22
Write Data
23
Ground
24
Write Gate
25
Ground
26
Track 00
27
Ground
28
Write Protect
29
Ground
30
Read Data
31
Ground
32
Side 1 Select
33
Ground
34
Diskette
5-22
Pin #
Definition
Chapter 5: Advanced Motherboard Setup
IDE Connector
There are no jumpers to configure
the onboard IDE interface "IDE".
See the table below for pin definitions.
IDE Drive Connectors
Pin Definitions (IDE)
Pin#
Definition
1
Reset IDE
2
Ground
3
Host Data 7
4
Host Data 8
5
Host Data 6
6
Host Data 9
7
Host Data 5
8
Host Data 10
9
Host Data 4
10
Host Data 11
11
Host Data 3
12
Host Data 12
13
Host Data 2
14
Host Data 13
15
Host Data 1
16
Host Data 14
17
Host Data 0
18
Host Data 15
19
Ground
20
Key
21
DRQ3
22
Ground
23
I/O Write
24
Ground
25
I/O Read
26
Ground
27
IOCHRDY
28
BALE
29
DACK3
30
Ground
31
IRQ14
32
IOCS16
33
Addr1
34
Ground
35
Addr0
36
Addr2
37
Chip Select 0
38
Chip Select 1
39
Activity
40
Ground
5-23
Pin #
Definition
SUPERSERVER 5014C-MF User's Manual
Notes
5-24
Chapter 6: Advanced Chassis Setup
Chapter 6
Advanced Chassis Setup
This chapter covers the steps required to install components and perform maintenance on the SC513L-260 chassis. For component installation, follow the steps in
the order given to eliminate the most common problems encountered. If a step is
unnecessary, skip ahead to the step that follows.
Tools Required
The only tool you will need to install components and perform maintainance is a
Philips screwdriver.
6-1
Static-Sensitive Devices
Electric Static Discharge (ESD) can damage electronic components. To prevent
damage to any printed circuit boards (PCBs), it is important to handle them very
carefully. The following measures are generally sufficient to protect your equipment
from ESD discharge.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing any board from its antistatic
bag.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the motherboard, add-on cards and peripherals back into their antistatic bags
when not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When
unpacking the board, make sure the person handling it is static protected.
6-1
SUPERSERVER 5014C-MF User's Manual
Figure 6-1. Chassis Front View
Figure 6-2. Chassis Rear View
6-2
Control Panel
The control panel (located on the front of the chassis) must be connected to the
JF1 connector on the motherboard to provide you with system control buttons and
status indicators. These wires have been bundled together in a ribbon cable to
simplify the connection. Connect the cable from JF1 on the motherboard to JP4
on the Control Panel PCB (printed circuit board). Make sure the red wire plugs
into pin 1 on both JF1 and JP4. Pull all excess cabling out of the airflow path. The
LEDs inform you of system status. See Chapter 3 for details on the LEDs and the
control panel buttons. Details on JF1 can be found in Chapter 5.
6-2
Chapter 6: Advanced Chassis Setup
6-3
System Fan
A 10-cm blower fan provides the cooling for the SuperServer 5014C-MF. The chassis includes air seals under the blower fan and at the chassis cross section, which
separates the drive bay area from the motherboard area of the chassis to promote
better airflow. It is highly important that the air seal is properly installed and making
a good seal in order for the cooling air to circulate properly through the chassis.
The fan can adjust its speed according to the heat level sensed in the system,
which results in more efficient and quieter fan operation. Fan speed is controlled
by a setting in BIOS (see page 7-11).
System Fan Failure
If the fan fails, you will need to have it replaced with the same type. Contact your
vendor or Supermicro for information on replacement fans.
6-4
Drive Bay Installation/Removal
Accessing the Drive Bay
Hard Drive: The hard drive in the 5014C-MF is not hot-swappabe. The system
must be shutdown and power removed when the hard drive is installed removed.
You must also first remove the cover to access the inside of the system. Proceed
to the next section for instructions.
CD-ROM/Floppy Disk Drives: There is no floppy drive or CD-ROM drive included
in the 5014C-MF.
6-3
SUPERSERVER 5014C-MF User's Manual
Serial ATA Drive Installation
1. Accessing the inside of the system
The Serial ATA drive is installed internally in the 5014C-MF. To add or remove the
Serial ATA drive, you must first remove the top chassis cover to gain access to the
inside of the system.
First, power down the system (it is also recommended to remove the AC power
cord) then release the retention screws near the handles that secure the unit to
the rack. Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click"). Next, remove the screw at the back of the chassis
that secures the top cover to the chassis. Depress the two buttons on the top of
the chassis to release the top cover from the locked position. Push the cover away
from you until it stops. You can then lift the top cover from the chassis to gain full
access to the inside of the server.
2. Installing/removing a Serial ATA drive
The hard drive is mounted in a tray at the right rear area of the server. The tray is
quipped with rubber grommets to reduce vibration (Figure 6-3, #1). Remove the
screws that secure the hard drive to the chassis and then lift it of the standoffs, as
shown in Figure 6-4. To remove a hard drive, unscrew the screws that secure it
to the tray (Figure 6-3, #3) and then remove the drive. To add a drive, position it
in the tray with the printed circuit board side facing down and with the holes in the
drive and the holes in the tray aligned. You can install it in either the top or the
bottom half of the tray. Then secure the drive to the tray with four screws (two on
each side), as shown in Figure 6-3.
6-4
Chapter 6: Advanced Chassis Setup
Figure 6-3. Internal Hard Drive Bay
Figure 6-4. Removing/Installing the Hard Drive
6-5
SUPERSERVER 5014C-MF User's Manual
6-5
Power Supply
The SuperServer 5014C-MF has a single 260 watt power supply. This power supply has the capability of operating at 100 - 240 input volts. Shutdown the system
and then unplug the AC power cord to completely remove power from the system
before removing the power supply.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need to replace
the power supply unit. Replacement units can be ordered directly from Supermicro
(PWS-0055 - see contact infomation in Chapter 1).
Replacing the Power Supply
1. Accessing the inside of the SuperServer 5014C-MF
To replace a power supply, you must first remove the top chassis cover. To do so,
first release the retention screws near the handles that secure the unit to the rack.
Grasp the two handles on either side and pull the unit straight out until it locks (you
will hear a "click"). Next, remove the screw at the back of the chassis that secures
the top cover to the chassis. Depress the two buttons on the top of the chassis to
release the top cover from the locked position. Push the cover away from you until
it stops. You can then lift the top cover from the chassis to gain full access to the
inside of the server.
2. Removing the power supply
First shut down the system and unplug the power cord. To remove the failed power
unit, remove the two screws on the back of the power supply, which secure it to
the chassis. You can then lift the unit straight out of the chassis. (The power cord
should have already been removed.)
3. Installing a new power supply
Replace the failed unit with another unit of the same wattage. It is highly recommended to replace it with the exact same power supply. Carefully insert the new
unit into position in the chassis and secure it with the two screws at the rear of
the unit. Before reconnecting the power cord, make sure the power switch on the
power supply is in the off position. Then reconnect the power cord, replace the
chassis top cover and push the unit back into the rack. Finish by depressing the
power button on the front of the system.
6-6
Chapter 7: BIOS
Chapter 7
BIOS
7-1
Introduction
This chapter describes the AwardBIOS for the P8SCT. The Award ROM BIOS
is stored in a Flash chip and can be easily upgraded using a floppy disk-based
program.
Note: Due to periodic changes to the BIOS, some settings may have been added
or deleted and might not yet be recorded in this manual. Refer to the Manual
Download area of our web site for any changes to the BIOS that are not reflected
in this manual.
System BIOS
The BIOS is the Basic Input Output System used in all IBM® PC, XT™, AT®, and
PS/2® compatible computers. The AwardBIOS Flash chip stores the system parameters, such as amount of memory, type of disk drives and video displays, etc.
CMOS requires very little power. When the computer is turned off, a back-up battery
provides power to the BIOS Flash chip, enabling it to retain the system parameters.
Each time the computer is powered-on, the computer is then configured with the
values stored in the BIOS ROM by the system BIOS, which gains control when the
computer is powered on.
How To Change the Configuration Data
The CMOS information that determines the system parameters may be changed
by entering the BIOS Setup utility. This Setup utility can be accessed by pressing
<Del> at the appropriate time during system boot.
Starting the Setup Utility
Normally, the only visible POST (Power On Self Test) routine is the memory test. As
the memory is being tested, press the <Delete> key to enter the main menu of the
BIOS Setup utility. From the main menu, you can access the other setup screens,
such as the Chipset and Power menus. Section 7-3 gives detailed descriptions of
each parameter setting in the Setup utility.
7-1
SUPERSERVER 5014C-MF User's Manual
7-2
Running Setup
*Optimal default settings are in bold text unless otherwise noted.
The BIOS setup options described in this section are selected by choosing the appropriate text from the Main BIOS Setup screen. All displayed text is described in
this section, although the screen display is often all you need to understand how
to set the options (see on next page).
When you first power on the computer, the AwardBIOS™ is immediately activated.
While the BIOS is in control, the Setup program can be activated in one of two
ways:
1.
2.
By pressing <Del> immediately after turning the system on, or
When the following message appears briefly at the bottom of the screen
during the POST (Power On Self-Test), press the <Del> key to activate
the Main Setup Menu.
Press DEL to enter SETUP
7-3
Main BIOS Setup
All Main Setup options are described in this section. The Main BIOS Setup screen
is displayed below.
Use the <Up> <Down> arrow keys or the <Tab> key to move among the different
settings in the above menu.
Press the <Esc> key to exit the CMOS Setup Menu and use the <Left> <Right> arrow
keys to enter the other categories of the BIOS settings. The next section is described
in detail to illustrate how to navigate through the menus.
7-2
Chapter 7: BIOS
Date/Time
Set the system date and time. Key in the correct information in the "mm", "dd"
and "yy" fields. Press the "Enter" key to save the data.
Legacy Diskette A/Legacy Diskette B
This setting allows the user to set the type of floppy disk drive installed as diskette
A and diskette B. The options are None, 360Kb 5.25 in, 1.2MB 5.25 in, 720Kb 3.5
in, 1.44/1.25MB, 3.5 in and 2.88MB 3.5 in.
Swap Floppy Drive
If the system has two floppy drives, enable this feature to assign physical drive
B to logical drive A or physical drive A to logic drive B. The options are Enabled
and Disabled.
IDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, IDE
Channel 2 Master/Slave, IDE Channel 3 Master/Slave
These settings allow the user to set the parameters of the IDE Channel 0 Master/
Slave to IDE Channel 3 Master/Slave slots. Hit <Enter> to activate the following
sub-menu screen for detailed options of these items. Set the correct configurations
accordingly. The items included in the submenu are:
7-3
SUPERSERVER 5014C-MF User's Manual
IDE HDD Auto-Detection
This option allows the user to determine the manner in which the AwardBIOS
sets the settings for IDE Channel 0 to IDE Channel 3 Master Devices. The
options are "None", "Auto" and "Manual."
IDE Channel 0 to IDE Channel 3 Master
Press the <Enter> key to activate the 'IDE HDD Auto-Detection" function, which
will allow the BIOS to automatically detect the status of the IDE HDD installed
in the system, such as the size, the number of cylinders, the configurations of
items such as Head, Precomp, Landing Zone and Sector. The options are None,
Auto and Manual.
Access Mode
This item determines the location through which the AwardBIOS accesses the IDE
Primary Master Device. The settings are "CHS", "LBA", "Large", and "Auto".
Halt On
This item allows the user to select the situation in which the BIOS will stop the
POST process and notify you about the status of the system. The settings are
"All Errors", "No Errors", "All, But Keyboard", "All, But Diskette", and "All, But
Disk/Key".
Total Physical Memory/Total System Resources/Total Available
Memory
These are displays that inform you how much of each type of memory is recognized
as being present in the system.
7-4
Chapter 7: BIOS
7-4
Advanced BIOS Setup
Choose the Advanced BIOS Setup from the Award BIOS main menu with the Left/
Right arrow keys. You should see the following display. Select one of the items in the
left frame of the screen to go to the sub screen for that item. The Advanced BIOS Setup
options are displayed by highlighting the option using the arrow keys. All Advanced
BIOS Setup options are described in this section.
7-4.1 Advanced BIOS Features
When the item of Advanced BIOS Features is highlighted, press the <Enter> key
to activate the submenu below:
Quick Boot
If enabled, this feature allows the system to skip certain tests while booting. This
will decrease the time needed to boot the system. The settings are "Enabled" and
"Disabled".
Quiet Boot
This feature allows the user to enable "Quiet Boot". When set to Enabled, the
BIOS is in the graphic mode and displays only an OEM Logo during POST while
booting. If an error occurs, The system will automatically switch to the text mode.
The options are "Enabled" and "Disabled".
ACPI Function
Select "Enabled" to enable BIOS Support for the Advanced Configuration and Power
Interface features. The settings are "Enabled" or "Disabled".
7-5
SUPERSERVER 5014C-MF User's Manual
MPS Version Control
This setting allows you to select the MPS version for your operating system. The
options are "1.1" and "1.4".
Agent After Boot
Set this option to Enabled to keep the "Agent" of Remote Access running after OS
bootup. The options are "Enabled" and "Disabled".
PWRON After PWR-Fail
This setting allows the user to determine how the system will respond when power
is reapplied after a system shut down caused by power failure. The options are
"Off", "On" and "Former-Sts".
Watch Dog Timer Select
This setting is for enabling the Watch Dog feature. The options are Enabled and
Disabled. (Please refer to Chapter 2 for more details.)
7-4.2 Advanced Chipset Control
DRAM Data Integrity Mode
If enabled, this feature allows the data stored in the DRMA memory to be
integrated for faster data processing. The options are ECC and Non-ECC.
On-Chip Frame Buffer Size
This setting allows you to set On-Chip Frame Buffer Size. The options are "1
MB" and "8 MB."
SATA Mode
This feature allows you to select the channel for SATA mode. The options are
"IDE", "RAID" and "AHCI (Advanced Host Controller Interface)."
7-6
Chapter 7: BIOS
On-Chip Serial ATA
Select "Disabled" to disable the SATA Controller. Select "Auto" to allow the
BIOS to configure the SATA Controller automatically. Select "Combined Mode"
to use PATA and SATA Combined Mode. The maximum of 2 IDE drives in each
channel is allowed. Select "Enhanced Mode" to enable both SATA and PATA.
This mode will support up to 6 IDE drives. Select "SATA Only" to allow SATA to
operate in "Legacy Mode".
PATA IDE Mode
When the item -On-chip Serial ATA is set to Combined Mode, the user can select
either Primary or Secondary for Parallel ATA IDE. The options are Primary and
Secondary. If On-chip Serial ATA is set to Enhanced Mode, only Serial ATA
will be activated, and Primary PATA IDE will be available. Secondary PATA IDE
will not be available.
SATA Port
This setting allows you configure the setting for the SATA port. The options are
P1 and P3 is Secondary.
USB Controller
This setting allows you to enable or disable the USB Controller. The options are
Enabled and Disabled.
USB 2.0 Controller
This setting allows you to enable or disable USB 2.0 (EHCI) Controller. The
options are Enabled and Disabled.
USB Legacy Support
This setting allows you to enable or disable the functions of USB, Keyboard/Mouse
under POST and DOS. The options are "Disabled" and "Enabled."
7-7
SUPERSERVER 5014C-MF User's Manual
7-4.3 I/O Device Configuration
Onboard Serial Port1/Onboard Serial Port2
This setting allows the user to set the address and the corresponding IRQ for
Serial Port1 and Serial Port 2.
The options are "Disabled" , "3F8/IRQ4", "2F8/
IRQ3", "3E8/IRQ4", "2E8/IRQ3", and "Auto". The default setting for Serial Port1
is "3F8/IRQ4" and the default for Port 2 is "2F8/IRQ3".
Onboard Parallel Port
This setting allows the user to set the address and the corresponding IRQ for the
onboard parallel port. The options are "Disabled", "378/IRQ7", "278/IRQ5" and
"3BC/IRQ7".
Parallel Port Mode
This setting sets the mode for the onboard Parallel port. The options are "SPP,"
"EPP", "ECP" "ECP+EPP" and "Normal".
EPP Mode Select
This setting allows the user to select the EPP port type. The options are "EPP
1.9" and "EPP 1.7".
ECP Mode Use DMA
This setting allows the user to select the DMA channel for the ECP mode (port) to
use. The options are "1" and "3".
Power On Function
This setting allows the user to decide which method to use to power on the system.
The options are "Password", "Hot Key", "Mouse Left", "Mouse Right", "Any Key",
and "Button Only".
KB Power On Password
This setting allows the user to enter the Password when the system is powered
on via keyboard.
Hot Key Power On
This setting allows the user to decide which hot-keys to use in order to power on
the system. The options are "Ctrl-F1", "Ctrl-F2, Ctrl-F3", "Ctrl-F4", "Ctrl-F5", "CtrlF6", "Ctrl-F7", and "Ctrl-F8".
7-8
Chapter 7: BIOS
7-4.4
PnP/PCI Configuration
Choose PCI/PnP Configurations from the Award BIOS main menu with the Left/
Right arrow keys. You should see the following display:
Initial Display From
This feature sets the device that will initiate the monitor display when the system
is first turned on.
The options are "PCI Slot" and "PCI Ex(press)".
Reset Configuration Data
Enabling this setting resets the extended system configuration data when you exit
setup. Do this when you have installed a new add-on and the system reconfiguration
has caused such a serious conflict that the OS cannot reboot the system. The
options are "Enabled" and "Disabled." If this feature is set to Enabled, the following
item will display:
Resources Controlled By
This setting allows the BIOS to automatically configure all boot and Plug and Play
compatible devices. If you choose Auto, you cannot select the IRQ, DMA and
memory base address fields, because the BIOS automatically assigns them. The
options are "Auto (ESCD)" and "Manual".
IRQ Resources
If the above item-Resources Controlled By" is set to manual, the user is allowed
to assign an IRQ to a PCI Device or Reserve an IRQ for other purpose. The
options are: Auto (ESCD) and Manual.
IRQ-3,
IRQ-4,
IRQ-5,
IRQ-7,
IRQ-9,
IRQ-10,
IRQ-12,
IRQ-14,
IRQ-15
Onboard LAN Boot ROM
This feature allows the user to determine if the Boot ROMs of the Onboard LAN
chips should be activated. If activated, the user can boot the system from the
Onboard LAN chips. The options are Disabled, LAN1, LAN2 and Both.
7-9
SUPERSERVER 5014C-MF User's Manual
Maximum Payload Size
This setting allows the BIOS to set the maximum TLP Payload size for the PCI
Express devices in the system. The options are: "128 (bytes)", "256 (bytes)", "512
(bytes)", "1024 (bytes)", "2048 (bytes)", and "4096 (bytes)".
PCI Express Root Port Function
PCI Express Port 1/PCI Express Port 2/PCI Express Port 3/PCI
Express Port 4
Select "Enabled" to enable the PCI Express Root Port Functions for the PCI
Express port specified. The options are: "Disabled", "Enabled", and "Auto".
PCI-E Compliance Mode
This features allows the BIOS to set the version of PCI-E Compliance Mode for
the system. The options are: "v.1.0a" and "v.1.0".
PCI-X Frequency
This features allows the user to set the PCI-X slot frequency. The options are: "Auto,
PCI-33 MHz, PCI-66 MHz, PCIX-66 MHz, PCI-X 100 MHz and PCI-X 133 MHz."
7-10
Chapter 7: BIOS
7-4.5 Hardware Monitors
There are only three settings on this menu (below). The rest of this menu
shows various temperatures and voltage levels as indicated.
CPU Warning Temperature
This allows you to set the CPU warning temperature. If the CPU temperature reaches
this threshold, an alarm will activate and a warning message will be displayed
onscreen. The options are "Disabled", "500C/1220F", "600C/1400F", "650C/1490F",
"700C/1580F", "750C/1670F", "800C/1760F" and "850C/1850F".
Highlight this and hit <Enter> to see monitor data for the following items:
CPU Temperature:
System Temperature:
In addition to temperature monitoring, the status of the following items will also
be displayed:
Fan 1 Speed-Fan 5 Speed
Voltage Monitoring
Processor Vcore (V), 3.3V Vcc (V), 5V Vcc (V), -12V Vcc (V), +12V Vcc (V),
5V Standby, VBAT
Fan Speed Control (Fan1-Fan5)
When set to 3-pin, the onboard fan speed is controlled by the CPU temperature.
When the CPU temperature is higher, the fan speed will be higher as well. If set
to "Disable," the fan speed control is disabled and the onboard fan will run at the
full speed (12V) at all time. The options are: "Disabled" and "3-pin Server".
7-11
SUPERSERVER 5014C-MF User's Manual
7-4.6 Processor & Clock Options
Thermal Management
This setting determines the method used by the BIOS to control the thermal
management of the system. The options are "Thermal Monitor 1 (On die throttling)
" and "Thermal Monitor 2 (Ratio & VID transition)." (See Section 1-4 for details.)
Limit CPUID MaxVal
Select "Enabled" to set CUPID maximum value to 3. Select "Disabled" for Windows
XP OS. The options are "Enabled" and "Disabled."
Hyper-Threading
Set this option to "Enabled" to activate the hyper-threading function of the CPUs.
Enabling the hyper-threading function makes each CPU appear as two to any
programs that support it (you must have OS support also). The settings are
"Disabled" and "Enabled."
CPU Clock Ration
Use this option to set the clock ratio of the processor. Use number keys to enter
a number. The default setting is "14".
Spread Spectrum
Spread Spectrum is a technique used to stabilize a system by reducing the level of
ElectroMagnetic Interference. The options are "Enabled" and "Disabled."
7-12
Chapter 7: BIOS
7-4.7 DMI Event Log
DMI Event Log
This setting allows you to Enable or Disable the function of DMI Event Logging.
The options are Disabled and Enabled.
Clear All DMI Event Logs
Select Yes and press <Enter> to clear all DMI event logs. The default setting
is "Yes."
View DMI Event Log
Highlight this item and press <Enter> to view the contents of the event log.
Mark DMI Events as Read
Highlight this item and press <Enter> to mark the DMI events as read.
Event Log Capacity
This is a display to inform you of the event log capacity. It is not a setting.
Event Log Validity
This is a display to inform you of the event log validity. It is not a setting.
7-13
SUPERSERVER 5014C-MF User's Manual
7-4.8 Console Redirection
Console Redirection
This setting allows you to Enable or Disable the function of Console Redirection.
The options are Disabled and Enabled.
BAUD Rate
Select the BAUD rate for console redirection. The options are 300, 1200, 2400,
9600, 19.2K, 38.4K, 57.6K and 115.2K [-bits per second].
Agent Connect Via
This setting allows you to select the device to be used for Console
Redirection.
Agent Wait Time (Min)
This setting allows you to set the wait time for Console Redirection. The options
are 1 (Min), 2 (Min), 4 (Min), and 8 (Min).
7-14
Chapter 7: BIOS
7-5
Security
Choose Security from the Award BIOS main menu with the Left/Right arrow keys.
You should see the following display:
Set Supervisor Password
When the item "Set Supervisor Password" is highlighted on the above screen, press
the <Enter> key. When prompted, type the Supervisor Password in the dialogue
box to set or to change the Supervisor Password.
Set User Password
When the item "Set User Password" is highlighted on the above screen, press the
<Enter> key. When prompted, type the User Password in the dialogue box to set
or to change the User Password.
Password Check
This setting allows the user to determine if the password is required every time
when the system boots up or if the password is required only when you enter the
CMOS setup. The options are "System" and "Setup".
7-15
SUPERSERVER 5014C-MF User's Manual
7-6
Boot
Choose Boot from the Award BIOS main menu with the Left/Right arrow keys. You
should see the following display:
The Award BIOS attempts to load the operating system from devices specified
by the users in a user-specified sequence.
First Boot Device
This item allows the user to set the first boot-up device. The options are "Floppy",
"LS120", "HDD", "CDROM", "ZIP100", "USB-FDD", "USB-ZIP", "USB-CDROM",
"USB-HDD", "LAN" and "Disabled".
Second Boot Device
This item allows the user to set the second boot-up device. The options are "Floppy",
"LS120", "HDD", "CDROM", "ZIP100", "USB-FDD", "USB-ZIP", "USB-CDROM",
"USB-HDD", "LAN" and "Disabled".
Third Boot Device
This item allows the user to set the third boot-up device. The options are "Floppy",
"LS120", "HDD", "SCSI", "CDROM", "ZIP100", "USB-FDD", "USB-ZIP", "USBCDROM", "USB-HDD", "LAN" and "Disabled".
Boot Other Device
If enabled, this option enables the BIOS to load the OS from another device rather
than the ones that have been specified as the first, second and third boot up devices.
The settings are "Enabled" and "Disabled".
7-16
Chapter 7: BIOS
7-7
Exit
Choose Exit from the Award BIOS main menu with the Left/Right arrow keys. You
should see the following display:
Save & Exit Setup
When the item "Save & Exit Setup" is highlighted, press <Enter> to save the
changes you've made in the BIOS program (CMOS) and exit. Your system should,
then, continue with the boot-up procedure.
Exit without Saving
When the item "Exit without Saving" is highlighted, press <Enter> to exit the Setup
routine without saving any changes you may have made. Your system should then
continue with the boot-up procedure.
Load Fail-Safe Defaults
Highlight this item and hit <Enter> to load the default settings for all items in the
BIOS Setup. These are the safest settings to use.
Load Optimized Defaults
Highlight this item and hit <Enter> to load the optimized settings for all items in the
BIOS Setup. These settings provide you with optimal system performance.
Discard Changes
When the item "Discard Changes" is highlighted, press <Enter> to discard any
changes you made to the BIOS settings and to stay in the BIOS Setup. Your system
should then continue with the boot-up procedure.
7-17
SUPERSERVER 5014C-MF User's Manual
Notes
7-18
Appendix A: BIOS POST Messages
Appendix A
BIOS POST Messages
During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is found, the BIOS will activate an alarm or display a message. The following is
a list of such BIOS messages.
Beeps
Error Messages
1 short beep
1 long beep+2 short beeps
1 long beep+9 short beeps
Repetitive pattern of beep+pause
Overheat LED is On with beeping
System Normal
VGA Errors
ROM Errors
Memory errors
Overheat
A-1
SUPERSERVER 5014C-MF User's Manual
Notes
A-2
Appendix B: BIOS POST Codes
Appendix B:
BIOS POST Codes
This section lists the POST (Power On Self Testing) Codes for the Award BIOS.
POST (hex)
Definition
CFh
Test CMOS R/W functionality
C0h
Early chipset initialization
- Disable shadow RAM
- Disable L2 cache (socket 7 or below)
- Program basic chipset registers
C1h
Detect memory
- Auto detection of DRAM size, type and ECC
- Auto detection of L2 cache (socket 7 or below)
C3h
Expand compressed BIOS code to DRAM
C5h
Call chipset hook to copy BIOS back to E000 & F000 shadow RAM
0h1
Expand the Xgroup codes located in physical address 1000:0
02h
Reserved
03h
Initial Superio_Early_Init switch
04h
Reserved
05h
1. Blank out screen
2. Clear CMOS error flag
06h
Reserved
07h
1. Clear 8042 interface
2. Initialize 8042 self-test
08h
1. Test special keyboard controller for Winbond 977 series Super I/O chips
2. Enable keyboard interface
09h
Reserved
0Ah
1. Disable PS/2 mouse interface
2. Auto detect ports for keyboard & mouse followed by a port & interface swap (optional)
3. Reset keyboard for Winbond 977 series Super I/O chips
0Bh
Reserved
0Ch
Reserved
0Dh
Reserved
0Eh
Test F000h segment shadow to see whether it is R/W-able or not. If test fails, keep beeping the
speaker.
0Fh
Reserved
10h
Auto detect flash type to load appropriate flash R/W codes into the run time area in F000 for ESCD
& DMI support
11h
Reserved
B-1
SUPERSERVER 5014C-MF User's Manual
POST (hex)
Definition
12h
Use walking 1's algorithm to check out interface in CMOS circuitry. Also set real-time clock power
status, and then check for override.
13h
Reserved
14h
Program chipset default values into chipset. Chipset default values are MODBINable by OEM
customers.
15h
Reserved
16h
Initial Early_Init_Onboard_Generator switch
17h
Reserved
18h
Detect CPU information including brand, SMU type (Cyrix or Intel) and CPU level (586 or 686)
19h
Reserved
1Ah
Reserved
1Bh
Initial interrupts vector table. If no special specified, all H/W interrupts are directed to SPURIOUS_INT_HDLR & S/W interrupts to SPURIOUS_softHDLR.
1Ch
Reserved
1Dh
Initial EARLY_PMI_INIT switch
1Eh
Reserved
1Fh
Load keyboard matrix (notebook platform)
20h
Reserved
21h
HPM initialization
22h
Reserved
23h
1. Check validity of RTC value, e.g. a value of 5Ah is an invalid value for RTC minute.
2. Load CMOS settings into BIOS stack. If CMOS checksum fails, use default value instead.
3. Prepare BIOS resource map for PCI and PnP use. If ESCD is valid, take into consideration of
the ESCD's legacy information.
4. Onboard clock generator initialization. Disable respective clock resource to empty PCI & DIMM
slots.
5. Early PCI initialization:
- Enumerate PCI bus number
- Assign memory and I/O resource
- Search for a valid VGA device and VGA BIOS and put it into C000:0.
24h
Reserved
25h
Reserved
26h
Reserved
27h
Initialize INT 09 buffer
28h
Reserved
29h
1. Program CPU internal MTRR (P6 & PII) for 0-64K memory address.
2. Initialize the APIC for Pentium class CPU.
3. Program early chipset according to CMOS setup. Example: onboard IDE controller.
4. Measure CPU speed.
5. Invoke video BIOS.
2Ah
Reserved
2Bh
Reserved
2Ch
Reserved
2Dh
1. Initialize multi-language
2. Put information on screen display, including Award title, CPU type, CPU speed, etc.
2Eh
Reserved
B-2
Appendix B: BIOS POST Codes
POST (hex)
Definition
2Fh
Reserved
30h
Reserved
31h
Reserved
32h
Reserved
33h
Reset keyboard except Winbond 977 series Super I/O chips
34h
Reserved
35h
Reserved
36h
Reserved
37h
Reserved
38h
Reserved
39h
Reserved
3Ah
Reserved
3Bh
Reserved
3Ch
Test 8254
3Dh
Reserved
3Eh
Test 8259 interrupt mask bits for channel 1
3Fh
Reserved
40h
Test 8259 interrupt mask bits for channel 2
41h
Reserved
42h
Reserved
43h
Test 8259 functionality
44h
Reserved
45h
Reserved
46h
Reserved
47h
Initialize EISA slot
48h
Reserved
49h
1. Calculate total memory by testing the last double word of each 64K page.
2. Program writes allocation for AMDK5 CPU.
4Ah
1. Initialize multi-language
2. Put information on screen display, including Award title, CPU type, CPU speed, etc.
4Bh
Reserved
4Ch
Reserved
4Dh
Reserved
4Eh
1. Program MTRR of M1 CPU.
2. Initialize L2 cache for P6 class CPU & program CPU with proper cacheable range.
3. Initialize the APIC for P6 class CPU.
4. On MP platform, adjust the cacheable range to smaller one in case the cacheable ranges
between each CPU are not identical.
4Fh
Reserved
50h
Initialize USB
51h
Reserved
B-3
SUPERSERVER 5014C-MF User's Manual
POST (hex)
Definition
52h
Test all memory (clear all extended memory to 0)
53h
Reserved
54h
Reserved
55h
Display number of processors (multi-processor platform)
56h
Reserved
57h
1. Display PnP logo
2. Early ISA PnP initialization
- Assign CSN to every ISA PnP device
58h
Reserved
59h
Initialize the combined Trend anti-virus code
5Ah
Reserved
5Bh
Show message for entering AWDFLASH.EXE from FDD (optional feature)
5Ch
Reserved
5Dh
1. Initialize Init_Onboard_Super_IO switch
2. Initialize Init_Onboard_AUDIO switch
5Eh
Reserved
5Fh
Reserved
60h
Ok to enter Setup utility; i.e. not until this POST stage can users enter the CMOS Setup utility
61h
Reserved
62h
Reserved
63h
Reserved
64h
Reserved
65h
Initialize PS/2 mouse
66h
Reserved
67h
Prepare memory size information for function call: INT 15h ax=E820h
68h
Reserved
69h
Turn on L2 cache
6Ah
Reserved
6Bh
Program chipset registers according to items described in Setup and Auto-configuration table
6Ch
Reserved
6Dh
1. Assign resources to all ISA PnP devices
2. Auto assign ports to onboard COM ports if the corresponding item in Setup is set to "AUTO".
6Eh
Reserved
6Fh
1. Initialize floppy controller
2. Set up floppy related fields in 40:hardware
70h
Reserved
71h
Reserved
72h
Reserved
73h
Enter AWDFLASH.EXE if: (optional feature)
- AWDFLASH is found in floppy drive
- Alt+F2 is pressed
B-4
Appendix B: BIOS POST Codes
POST (hex)
Definition
74h
Reserved
75h
Detect and install all IDE devices: HDD, LS120, ZIP, CD-ROM, etc.
76h
Reserved
77h
Detect serial ports and parallel ports
78h
Reserved
79h
Reserved
7Ah
Detect and install co-processor
7Bh
Reserved
7Ch
Reserved
7Dh
Reserved
7Eh
Reserved
7Fh
1. Switch back to text mode if full screen logo is supported.
- If errors occur, report errors and wait for keys.
- If no errors occur or F1 key is pressed to continue:
- Clear EPA or customization logo
80h
Reserved
81h
Reserved
82h
1. Call chipset power management hook
2. Recover the text font used by EPA logo (not for full screen logo)
3. If password is set, ask for password
83h
Save all data in stack back to CMOS
84h
Initialize ISA PnP boot devices
85h
1. USB final initialization
2. NET PC: Build SYSID structure
3. Switch screen back to text mode
4. Set up ACPI table at top of memory
5. Invoke ISA adapter ROMs
6. Assign IRQs to PCI devices
7. Initialize APM
8. Clear noise of IRQs
86h
Reserved
87h
Reserved
88h
Reserved
89h
Reserved
90h
Reserved
91h
Reserved
92h
Reserved
93h
Read HDD boot sector information for Trend anti-virus code
B-5
SUPERSERVER 5014C-MF User's Manual
POST (hex)
Definition
94h
1. Enable L2 cache
2. Program boot up speed
3. Chipset final initialization
4. Power management final initialization
5. Clear screen and display summary table
6. Program K6 write allocation
7. Program P6 class write combining
95h
1. Program daylight savings
2. Update keyboard LED and typematic rate
96h
1. Build MP table
2. Build and update ESCD
3. Set CMOS century to 20h or 19h
4. Load CMOS time into DOS timer tick
5. Build MSIRQ routing table
FFh
Boot attempt (INT 19h)
B-6
Appendix C: Software Installation
Appendix C
Software Installation
If you do not wish to configure SATA RAID, proceed directly to Section C-3.
After all the hardware has been installed, you must first configure Intel's ICH6R
SATA RAID before you install the Operating System and other software drivers.
The necessary drivers and user's guides are all included on the Supermicro CDs
that came packaged with the system.
C-1 Configuring Intel's ICH6R SATA RAID Function
To configure SATA RAID functions, you must first configure the desired RAID
level with the ICH6R SATA RAID Utility program before you install the operating
system and other software drivers. The necessary drivers are all included on the
Supermicro CDs that came packaged with your system.
Note: the current ICH6R SATA RAID Utility version can only support Windows
XP/2000/2003 and Linux/SuSE Operating Systems.
Serial ATA (SATA)
Serial ATA (SATA) is a physical storage interface that uses a single cable with a
minimum of four wires to create a point-to-point connection between devices. It
is a serial link that supports SATA transfer rates of up to 150MBps. Because the
serial cables used in SATA are thinner than the traditional cables used in Parallel ATA (PATA), SATA systems have better airflow and can be installed in smaller
chassis than PATA. In addition, the cables used in PATA can only extend to 40
cm, while SATA cables can extend up to one meter. Overall, SATA provides better
functionality than PATA.
Intel's ICH6R Serial RAID
Located in the South Bridge of the E7221 Copper River Chipset, the I/O Controller
Hub (ICH6R) provides the I/O subsystem with access to the rest of the system.
It supports a one-channel Ultra ATA/100 Bus Master IDE controller (PATA) and a
Serial ATA (SATA) Host Controller, which supports up to four Serial ATA ports and
up to two sets of RAID drives. RAID 0 (Striping), RAID 1 (Mirroring) and RAID
10 (Striping+Mirroring) are supported. The ICH6R supports both PATA and SATA
device configurations.
ATA Operating Modes
You can select from the following two modes: Legacy mode and Native mode.
C-1
SUPERSERVER 5014C-MF User's Manual
SATA Operating Modes
You can select from the following modes: Auto, Combined, Enhanced, and SATA
Only Mode. The number of devices supported by these modes are listed below:
*SATA Only: The maximum of 4 devices are supported (4 SATA)
*Auto Mode: The maximum of 6 devices supported (4 SATA + 2 IDE)
*Enhanced Mode: The maximum of 6 devices supported (4 SATA + 2 IDE)
*Combined Mode: The maximum of 4 devices supported (2 SATA + 2 IDE)
Configuring BIOS Settings (Native Mode)
1. Press the Del key during system bootup to enter the BIOS Setup Utility.
Note: If it is the first time to power on the system, we recommend that you load the
Optimized Default Settings. If you have already done so, please skip to Step 3.
2. Use the arrow keys to select the "Exit" Menu. Once in the "Exit" Menu, scroll
down the menu to select the item "Load Optimized Default Settings" and press the
Enter key. Select OK to confirm the selection. Press the Enter key to load the
default settings to the BIOS.
3. Use the arrow keys to select the "Advanced" Menu in BIOS.
4. Scroll down to the item "Advanced Chipset Control" and press the <Enter> key
to select this option.
5. Select the item "On-Chip Serial ATA", and press the <Enter> key. When the
sub-menu appears, select the item "Enhanced Mode".
6. Scroll up to the item "SATA Mode" and press the <Enter> key to select this option. When the sub-menu appears, select the item "RAID".
7. Tap "Esc" and scroll down to "Exit". Select "Save and Exit" from the "Exit" menu.
Press the <Enter> key to save the changes and exit the BIOS.
8. Once you've exited the BIOS Utility, the system will re-boot.
C-2
Appendix C: Software Installation
Using the LSI ICH6R SATA RAID Utility Driver
Accessing the LSI SATA RAID Utility
After the system exits from the BIOS Setup Utility, it will automatically reboot. To
run the LSI Logic Embedded SATA RAID Setup Utility, press the <CTRL> and the
<M> keys simultaneously during system bootup as shown in the screen below:
Once you've entered the LSI SATA RAID Setup Utility, the main menu displays as
shown below:
Note: Please refer to the LSI User's Guide (included in the CD) to install the LSI
SATA RAID Controller driver.
C-3
SUPERSERVER 5014C-MF User's Manual
Creating New A SATA RAID:
1. From the Main Menu (shown on the previous page), select "Configure" and press
the <Enter> key. The following screen displays:
2. From the Configuration submenu, select "New Configuration" and press the
<Enter> key to activate the following submenu:
3. When the submenu appears, highlight "Yes" and press the <Enter> key at the
prompt (as shown above) to proceed with the new RAID configuration. The following screen displays:
C-4
Appendix C: Software Installation
4. When the screen shown above appears, press the space bar on your keyboard
to select the physical drives that you wish to configure as RAID drives. The text of
the selected drives will change from "Ready" to "Online" as shown below:
5. When the screen shown above displays, press <F10> to associate the selected
physical drive with the current array. Once you've finished creating the current array, press <Enter>. The following screen appears:
C-5
SUPERSERVER 5014C-MF User's Manual
6. In the above display, press the space bar to select the array.
7. When the pop-up submenu, indicating "SPAN-1" appears as shown above, use
the space bar to configure the selected drive and press <F10>. The following
screen appears:
C-6
Appendix C: Software Installation
8. When the screen shown above appears, highlight RAID 1 to select it (this is the
default setting), or press <Enter> for other RAID options.
9. After completing the RAID level selection, use the arrow keys to highlight "Accept", and press <Enter>.
10. Once you've created a new RAID, save the configuration and proceed with
disk drive initialization.
C-7
SUPERSERVER 5014C-MF User's Manual
Initializing Disk Drives
If an installed disk does not appear in the disk selection list for creating a new array
or if it appears grayed out, you may have to initialize it before you can use it as
part of an array. Drives attached to the controller must be initialized before they
can be used in an array.
Caution: Initializing a disk overwrites the partition table on the disk and makes any
data on the disk inaccessible. If the drive is used in an array, you may not be able
to use the array again.
Do not initialize a disk that is part of a boot array. To determine which disks are
associated with a particular array, please refer to Viewing Array Properties.
1. Use the arrow keys to select "Initialize" from the LSI SATA RAID main menu
(shown below), and press the <Enter> key.
2. Select "Logical Drive" from the pop-up submenu and press <Enter>.
3. Use the space bar on your keyboard to select the Logical Drive you wish to
initialize and press <Enter>.
C-8
Appendix C: Software Installation
4. After selecting the Logical Drive, press <F10> to initialize the selected disk
drive.
5. When prompted for confirmation, use the arrow keys to select "Yes" and press
<Enter>. A new screen will confirm the initialization of the selected disk drive.
Creating Hot Spare Drives
1. Use the arrow keys to select "Objects" from the LSI SATA RAID main menu and
press <Enter>.
2. Select "Physical Drive" and press <Enter>. The following menu displays.
C-9
SUPERSERVER 5014C-MF User's Manual
3. Use the space bar to select the physical drive you wish to configure as a Hot
Spare drive from the pop-up submenu and press <Enter>. The status of the disk
drive selected will be changed from "Ready" to "HOTSP".
Note: For detailed information regarding LSI's SATA RAID configuration, please refer to the LSI User's Manual included in the CD that came with the system. You can
also visit our web site at www. supermicro.com for the LSI's User's Manual.
C-10
Appendix C: Software Installation
C-2 Installing WindowsXP/2000/2003 for RAID Systems
Note: It is strongly recommended that you initialize the disk drives before installing
the OS. Refer to the previous section for disk drive initialization.)
1. Insert Supermicro's bootable CD that came with the system into the CD-ROM
drive during the system reboot. The "Super Micro Driver Diskette Maker" screen
displays.
2. Choose "Marvell Hercules II SATA Driver by 3rd Party (LSI)" from the items listed
and press <Enter>.
3. From the next screen displayed, choose the OS driver you want to install and
press <Enter>.
4. Insert a formatted diskette into drive A: and press <Enter> as prompted.
5. Exit the program after the process has completed. Then, reboot the system.
6. Insert Microsoft Windows OS Setup CD in the CD-ROM drive. The system will
boot up from the CD.
7. Press the <F6> key when the message "Press F6 if you need to install a third
party SCSI or RAID driver" is displayed.
8. When the Windows OS Setup screen appears, press <S> to specify additional
device(s).
9. Insert the driver diskette labelled "LSI Embedded Serial ATA RAID Controller
Driver" into your floppy drive and press the <Enter> key.
10. Choose "LSI Embedded Host Serial ATA RAID Controller" from the list indicated
in the Windows OS Setup Screen and press the <Enter> key.
11. Press the <Enter> key to continue the installation process. (If you need to specify
any additional devices to be installed, do so at this time.) Once all devices are
specified, press the <Enter> key to continue with the installation.
12. From the Windows OS Setup screen, press the <Enter> key. The OS setup
routine will automatically load all device files and continue the Windows OS installation.
13. After the Windows OS installation has completed, the system will automatically
reboot.
Note: To install operating systems other than a Windows OS, or to install other
software, please refer to the LSI User's manual included in the CD that came
with the system. You can also visit our web site at www. supermicro.com to
download the manual.
C-11
SUPERSERVER 5014C-MF User's Manual
C-3 Installing Other Software Programs and Drivers
Installing Other Drivers
After you've installed the Windows Operating System, a screen as shown in Figure
C-1 displays. You are now ready to install additional software programs and drivers. To install these software programs and drivers, click the icons to the right of
these items.
Figure C-1. Driver/Tool Installation Display Screen
Click the icons showing a hand writing on paper to view the readme files for each
item. Click the computer icons to the right of these items to install each item (from
top to the bottom) one at a time. After installing each item, you must re-boot
the system before moving on to the next item on the list. You should install
everything here except for the SUPER Doctor utility, which is optional. The bottom
icon with a CD on it allows you to view the entire contents of the CD.
Note: Please refer to the LSI User's Guide (included in the CD) for installing the
LSI SATA RAID Controller Driver. You can also download a copy of the guide from
our web site.
C-12
Appendix C: Software Installation
Supero Doctor III
The Supero Doctor III program is a web base management tool that supports remote
management capability. It includes Remote and Local Management tools. The local
management is called SD III Client. The Supero Doctor III program included on the
CDROM that came with your motherboard allows you to monitor the environment
and operations of your system. Supero Doctor III displays crucial system information
such as CPU temperature, system voltages and fan status. See the Figure below
for a display of the Supero Doctor III interface.
Note: The default User Name and Password for SuperDoctor III is ADMIN / ADMIN.
C-2. Supero Doctor III: Health Information
C-13
SUPERSERVER 5014C-MF User's Manual
C-3. Supero Doctor III: Remote Control
Note: SD III Software Revision 1.0 can be downloaded from our web site at: ftp://
ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's
Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For
Linux, we will still recommend Supero Doctor II.
C-14
Appendix D: System Specifications
Appendix D
System Specifications
Processors
Single Intel® Pentium® 4 LGA775 processor at an 800 MHz front side bus
speed or a single Intel® Celeron® processor at a 533 MHz FSB (hyper-threading
enabled)
Chipset
Intel E7221
BIOS
Award BIOS in 8 Mb Flash EEPROM
Memory Capacity
Four (4) DIMM slots to support a maximum up to 4 GB of unbuffered ECC or
non-ECC DDR2-533/400 SDRAM modules
Note: all memory modules should be the same size, speed and type
Serial ATA Controller
• Intel ICH6R on-chip controller for 4-port Serial ATA (JBOD supported)
Hard Drive Bay
One (1) fixed drive bay for one (1) 3.5" hard drive
PCI Expansion Slots
One (1) 64-bit 133 MHz (3.3V) PCI-X slot (bundled with a riser card)
Motherboard
Model: P8SCT (ATX Form Factor)
Dimensions: 12 x 9.5 in (305 x 241 mm)
Chassis
Model: SC513L-260 (1U Rackmount)
Dimensions: (WxHxD) 17.2 x 1.7 x 19.85 in. (437 x 43 x 504 mm)
D-1
SUPERSERVER 5014C-MF User's Manual
Weight
Gross Weight: 16.5 lbs. (7.5 kg.)
System Cooling
One (1) 10-cm 5K rpm cooling fan
One (1) air shroud
One (1) fan holder
System Input Requirements
AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 4A max
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 260W (Model# SP262-1S, Part# PWS-0055)
Rated Output Voltages: +3.3V (15A), +5V (25A), +12V (18A), -12V (1A),
+5Vsb (2A)
BTU Rating
1372 BTUs/hr (for rated output power of 260W)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions:
FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
D-2
Appendix D: System Specifications
Safety:
EN 60950/IEC 60950-Compliant
UL Listed (USA)
CUL Listed (Canada)
TUV Certified (Germany)
CE Marking (Europe)
D-3
SUPERSERVER 5014C-MF User's Manual
Notes
D-4

advertisement

Key Features

  • High-end single processor 1U rackmount server
  • SC513L-260 1U chassis
  • P8SCT motherboard
  • Supports Intel® Pentium® 4 LGA775 ("Prescott") type processors
  • Supports Intel® Celeron® processors
  • Onboard IDE controller
  • Two onboard Broadband BCM5721 Ethernet controllers
  • Serial ATA controller

Frequently Answers and Questions

What is the Supermicro SuperServer 5014C-MF?
The Supermicro SuperServer 5014C-MF is a high-end single processor, 1U rackmount server with state-of-the-art features. It's designed for professional system integrators and PC technicians.
What are the main components of the SuperServer 5014C-MF?
The SuperServer 5014C-MF consists of two main subsystems: the SC513L-260 1U chassis and the P8SCT motherboard.
What types of processors does the P8SCT motherboard support?
The P8SCT supports single Intel® Pentium® 4 LGA775 ("Prescott") type processors at an 800 MHz FSB or single Intel® Celeron® processors at a 533 MHz FSB.
What kind of memory does the SuperServer 5014C-MF use?
The P8SCT has four (4) 240-pin DIMM sockets that can support up to 4 GB of unbuffered ECC type DDR2-533/400 SDRAM modules.
What are the main features of the SC513L-260 chassis?
The SC513L-260 chassis features a unique design that places all I/O ports at the front of the chassis for easy access. It also includes a single 260W power supply, a Serial ATA subsystem, a control panel with LEDs and buttons, and an innovative cooling design with a 10-cm blower fan.

Related manuals

Download PDF

advertisement