Below you will find brief information for server SUPERSERVER 6014L-T. The SUPERSERVER 6014L-T is a high-end dual processor, 1U rackmount server featuring state-of-the-art technology. The 6014L-T is comprised of two main subsystems: the SC811LT-260 1U rackmount chassis and the X6DLP-EG2 serverboard. The X6DLP-EG2 supports Intel® Xeon® LV or ULV processors in 479-pin PGA sockets.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
120
SUPER ® SUPERSERVER 6014L-T USER’S MANUAL Revision 1.0 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent. IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product. Manual Revision 1.0 Release Date: March 6, 2006 Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright © 2006 by SUPER MICRO COMPUTER INC. All rights reserved. Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6014L-T. Installation and maintenance should be performed by experienced technicians only. The SuperServer 6014L-T is a high-end dual processor rackmount server based on the SC811LT-260 1U rackmount server chassis and the Super X6DLP-EG2 serverboard. The X6DLP-EG2 supports Intel® Xeon® LV or ULV processors in 479-pin PGA sockets. Manual Organization Chapter 1: Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the Super X6DLP-EG2 serverboard and the SC811LT-260 chassis. Chapter 2: Server Installation This chapter describes the steps necessary to install the SuperServer 6014L-T into a rack and check out the server configuration prior to powering up the system. If your server was ordered without the processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation. Chapter 3: System Interface Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system. iii SUPERSERVER 6014L-T User's Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6014L-T. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X6DLP-EG2 serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard. Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC811LT-260 1U rackmount server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans. Chapter 7: BIOS The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility. Appendix A: BIOS Error Beep Messages Appendix B: BIOS POST Checkpoint Codes Appendix C: Software Installation Appendix D: System Specifications iv Preface Notes v SUPERSERVER 6014L-T User's Manual Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Chapter 1: Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ..................................................................................... 1-2 1-3 Server Chassis Features ................................................................................ 1-5 1-4 Contacting Supermicro ................................................................................... 1-7 Chapter 2: Server Installation 2-1 Overview ......................................................................................................... 2-1 2-2 Unpacking the System ................................................................................... 2-1 2-3 Preparing for Setup ........................................................................................ 2-1 Choosing a Setup Location ...................................................................... 2-2 Rack Precautions ..................................................................................... 2-2 Server Precautions ................................................................................... 2-2 Rack Mounting Considerations ................................................................ 2-3 2-4 Installing the System into a Rack ................................................................... 2-4 Identifying the Sections of the Rack Rails ............................................... 2-4 Installing the Rear Inner Rails ................................................................. 2-4 Installing the Rack Rails .......................................................................... 2-5 Installing the Server into the Rack ........................................................... 2-6 Installing the Server into a Telco Rack .................................................... 2-7 2-5 Checking the Serverboard Setup ................................................................... 2-8 2-6 Checking the Drive Bay Setup ..................................................................... 2-10 Chapter 3: System Interface 3-1 Overview ......................................................................................................... 3-1 3-2 Control Panel Buttons .................................................................................... 3-1 Reset ........................................................................................................ 3-1 Power ....................................................................................................... 3-1 3-3 Control Panel LEDs ........................................................................................ 3-2 Overheat/Fan Fail .................................................................................... 3-2 NIC2 ......................................................................................................... 3-2 NIC1 ......................................................................................................... 3-2 HDD .......................................................................................................... 3-2 vi Table of Contents Power ....................................................................................................... 3-3 3-4 Serial ATA Drive Carrier LEDs ......................................................................... 3-3 Chapter 4: System Safety 4-1 Electrical Safety Precautions .......................................................................... 4-1 4-2 General Safety Precautions ........................................................................... 4-2 4-3 ESD Precautions ............................................................................................ 4-3 4-4 Operating Precautions .................................................................................... 4-4 Chapter 5: Advanced Serverboard Setup 5-1 Handling the Serverboard .............................................................................. 5-1 5-2 Serverboard Installation .................................................................................. 5-2 5-3 Processor and Heatsink Installation ............................................................... 5-3 5-4 Connecting Cables ......................................................................................... 5-6 Connecting Data Cables .......................................................................... 5-6 Connecting Power Cables ....................................................................... 5-6 Connecting the Control Panel .................................................................. 5-7 5-5 I/O Ports ......................................................................................................... 5-7 5-6 Installing Memory ........................................................................................... 5-8 5-7 Adding PCI Cards ........................................................................................... 5-9 5-8 Serverboard Details ...................................................................................... 5-10 Super X6DLP-EG2 Layout ..................................................................... 5-10 Super X6DLP-EG2 Quick Reference ..................................................... 5-11 5-9 Connector Definitions ................................................................................... 5-12 ATX Power Connector ........................................................................... 5-12 Processor Power Connector .................................................................. 5-12 NMI Button ............................................................................................. 5-12 Power On LED ....................................................................................... 5-12 PW_ON Connnector .............................................................................. 5-12 HDD LED ............................................................................................... 5-13 NIC1/NIC LEDs ...................................................................................... 5-13 Overheat/Fan Fail LED .......................................................................... 5-13 Power Fail LED ...................................................................................... 5-13 Reset Button .......................................................................................... 5-14 Power Button .......................................................................................... 5-14 JLAN1/2 .................................................................................................. 5-14 Chassis Intrusion .................................................................................... 5-14 Universal Serial Bus ............................................................................... 5-15 Universal Serial Bus Headers ................................................................ 5-15 Fan Headers .......................................................................................... 5-15 vii SUPERSERVER 6014L-T User's Manual Speaker/Power LED/Keylock ................................................................. 5-16 Wake-On-Ring ........................................................................................ 5-16 Wake-On-LAN ........................................................................................ 5-16 Power Fault ............................................................................................ 5-17 ATX PS/2 Keyboard and PS/2 Mouse Ports ......................................... 5-17 SMB ........................................................................................................ 5-17 Serial Ports ............................................................................................. 5-17 5-10 Jumper Settings ............................................................................................ 5-18 Explanation of Jumpers ......................................................................... 5-18 CMOS Clear ........................................................................................... 5-18 JLAN1/2 Enable/Disable ........................................................................ 5-18 VGA Enable/Disable ............................................................................... 5-19 SMBus to PCI ........................................................................................ 5-19 Power Force On ..................................................................................... 5-19 Watch Dog ............................................................................................. 5-19 Alarm Reset ........................................................................................... 5-20 5-11 Onboard Indicators ....................................................................................... 5-20 JLAN LEDs ............................................................................................. 5-20 System Status LED ................................................................................ 5-20 Onboard LED Indicators ........................................................................ 5-21 5-12 Parallel Port, Floppy, IDE and SATA Drive Connections ............................. 5-22 Parallel Port ............................................................................................ 5-22 Floppy Connector ................................................................................... 5-23 SATA Connectors ................................................................................... 5-23 IDE Connector ........................................................................................ 5-24 Chapter 6: Advanced Chassis Setup 6-1 Static-Sensitive Devices ................................................................................. 6-1 6-2 Control Panel .................................................................................................. 6-2 6-3 System Fans ................................................................................................... 6-3 System Fan Failure .................................................................................. 6-3 6-4 Drive Bay Installation/Removal ...................................................................... 6-3 Accessing the Drive Bays ........................................................................ 6-3 Serial ATA Drive Installation ..................................................................... 6-4 Serial ATA Backplane ............................................................................... 6-5 CD-ROM Drive Installation ....................................................................... 6-6 6-5 Power Supply ................................................................................................. 6-7 Power Supply Failure ............................................................................... 6-7 Replacing the Power Supply .................................................................... 6-7 viii Table of Contents Chapter 7: BIOS 7-1 Introduction ..................................................................................................... 7-1 7-2 Main Setup ..................................................................................................... 7-2 7-3 Advanced Settings .......................................................................................... 7-3 7-4 Boot Settings ................................................................................................ 7-15 7-5 Security Settings ........................................................................................... 7-18 7-6 Exit Options .................................................................................................. 7-19 Appendices: Appendix A: BIOS Error Beep Codes ...................................................................... A-1 Appendix B: BIOS POST Checkpoint Codes .......................................................... B-1 Appendix C: Software Installation ........................................................................... C-1 Appendix D: System Specifications ........................................................................ D-1 ix SUPERSERVER 6014L-T User's Manual Notes x Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview The SuperServer 6014L-T is a high-end dual processor, 1U rackmount server featuring state-of-the-art technology. The 6014L-T is comprised of two main subsystems: the SC811LT-260 1U rackmount chassis and the X6DLP-EG2 serverboard. Please refer to our web site for information on operating systems that have been certified for use with the 6014L-T (www.supermicro.com). In addition to the serverboard and chassis, various hardware components may have been included with the 6014L-T, as listed below. Two (2) CPU heatsinks (SNK-P0019) One (1) slim CD-ROM drive [CDM-TEAC-24(B)] One (1) floppy drive [FPD-PNSC-02(01)] SATA Accessories: Two (2) SATA hard drive carriers (CSE-PT-10(B)) One (1) internal SATA backplane (CSE-SATA-810) Two (2) SATA cables (CBL-0061) One (1) 3.3V 64-bit, 66 MHz PCI-X slot riser card (CSE-RR1U-X) Two (2) 4-cm high-performance fans (FAN-0061) Rackmount hardware with screws (CSE-PT8): Two (2) rack rail assemblies Six (6) brackets for mounting the rack rails in a rack/telco rack One (1) CD containing drivers and utilities SuperServer 6014L-T User's Manual Note: "B" indicates part is also available in black. 1-1 SUPERSERVER 6014L-T User's Manual 1-2 Serverboard Features At the heart of the SuperServer lies the X6DLP-EG2, a dual processor serverboard based on Intel's E7520 chipset and designed to provide maximum performance. Below are the main features of the X6DLP-EG2. Processors The X6DLP-EG2 supports single or dual Intel® Xeon® LV or ULV processors in 479-pin PGA sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com). Memory The X6DLP-EG2 has four (4) 240-pin DIMM sockets that can support up to 16 GB of registered ECC DDR2-400 SDRAM. The memory bus is a dual-channel configuration and memory modules must be installed in pairs (two at a time). All memory modules used to populate the system should be the same size, type and speed. Serial ATA The 6300ESB South Bridge portion of the chipset includes a Serial ATA controller that supports a four-port SATA subsystem (RAID 0, 1 and 10 supported). The Serial ATA drives are hot-swappable units. Note: The operating system you use must have RAID support to enable the hotswap capability and RAID function of the Serial ATA drives. PCI Expansion Slots The X6DLP-EG2 has two 64-bit, 66 MHz (3.3V) PCI-X slots, two x8 PCI-Express slots and one 32-bit, 33 MHz (5V) PCI slot. When configured as the X6DLP-EG2, the 64-bit, 133 MHz PCI-X slot is available with the use of a riser card (included with the system). Ethernet Ports The X6DLP-EG2 has one Intel 82573V and one Intel 82573L single port Ethernet controllers to support two Gigabit LAN ports. (Supports 100/1000 BASE-T, RJ45 output.) 1-2 Chapter 1: Introduction Onboard Controllers/Ports An onboard IDE controller supports up to four UltraDMA/100 hard drives or ATAPI devices. Onboard I/O backpanel ports include one COM port, a VGA port, two USB ports, PS/2 mouse and keyboard ports and two GLAN (NIC) ports. Other Features Other onboard features that promote system health include voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue. 1-3 SUPERSERVER 6014L-T User's Manual CPU1 CPU2 667 MT/s DDR2-400 Group A DIMM 1A Links0-7 8x PCI-Express (Slot 6) DIMM 2A DIMM 3A 8x PCI-Express (Slot 3) Group B Links0-7 LAN 82573 LAN 82573 E7520 MCH DIMM 4A DIMM 1B DIMM 2B DIMM 3B DIMM 4B PCI-X 66 MHz (Slot 6) SATA Ports (4) PCI-X 66 MHz (Slot 5) 6300ESB IDE (ATA133) PCI 33 MHz (Slot 1) USB Ports (4) ATI Rage LPC BIOS Kybd/ Mouse S I/O Floppy IPMI COM Ports Figure 1-1 . Intel E7520 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. 1-4 Chapter 1: Introduction 1-3 Server Chassis Features The following is a general outline of the main features of the SC811LT-260 chassis. System Power When configured as a SuperServer 6014L-T, the SC811LT-260 chassis includes a single 260W power supply. Serial ATA Subsystem For the 6014L-T, the SC811LT-260 chassis was designed to support two Serial ATA hard drives, which are hot-swappable units. Note: The operating system you use must have RAID support to enable the hotswap capability of the Serial ATA drives. Control Panel The SC811LT-260's control panel provides important system monitoring and control information. LEDs indicate power on, network activity, hard disk drive activity and system overheat conditions. The control panel also includes a main power button and a system reset button. Rear I/O Panel The SC811LT-260 is a 1U rackmount chassis. Its I/O panel provides one PCI expansion slot, one COM port (another is internal), two USB ports, PS/2 mouse and keyboard ports, a VGA port and two Gb Ethernet ports. (See Figure 1-2.) 1-5 SUPERSERVER 6014L-T User's Manual Figure 1-2. Rear I/O Panel Cooling System The SC811LT-260 chassis has an innovative cooling design that features three 4-cm high-performance system cooling fans. Each of these fans plug into a chassis fan header on the serverboard. An air shroud channels the airflow generated by the fans to efficiently cool the processor area of the system. A fan speed control setting in BIOS allows fan speed to be determined by system temperature [the recommended setting is 3-pin (Server)]. 1-6 Chapter 1: Introduction 1-4 Contacting Supermicro Headquarters Address: Tel: Fax: Email: Web Site: SuperMicro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. +1 (408) 503-8000 +1 (408) 503-8008 [email protected] (General Information) [email protected] (Technical Support) www.supermicro.com Europe Address: Tel: Fax: Email: SuperMicro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands +31 (0) 73-6400390 +31 (0) 73-6416525 [email protected] (General Information) [email protected] (Technical Support) [email protected] (Customer Support) Asia-Pacific Address: SuperMicro, Taiwan 4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: [email protected] Tel: 886-2-8228-1366, ext.132 or 139 1-7 SUPERSERVER 6014L-T User's Manual Notes 1-8 Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 6014L-T up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your 6014L-T system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a serverboard, processor, system memory etc., please turn to the chapter or section noted in each step for details on installing specific components. 2-2 Unpacking the System You should inspect the box the SuperServer 6014L-T was shipped in and note if it was damaged in any way. If the server itself shows damage, you should file a damage claim with the carrier who delivered it. Decide on a suitable location for the rack unit that will hold the SuperServer 6014LT. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section. 2-3 Preparing for Setup The box the SuperServer 6014L-T was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow. 2-1 SUPERSERVER 6014L-T User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. - This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). ! Warnings and Precautions! ! Rack Precautions - Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. - In single rack installation, stabilizers should be attached to the rack. - In multiple rack installations, the racks should be coupled together. - Always make sure the rack is stable before extending a component from the rack. - You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable. Server Precautions - Review the electrical and general safety precautions in Chapter 4. - Determine the placement of each component in the rack before you install the rails. - Install the heaviest server components on the bottom of the rack first, and then work up. - Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure. - Allow the hot plug SATA drives and power supply modules to cool before touching them. - Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. 2-2 Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra). Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading. Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Ground A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). 2-3 SUPERSERVER 6014L-T User's Manual 2-4 Installing the System into a Rack This section provides information on installing the SuperServer 6014L-T into a rack unit. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the unit into a rack with the rack rails provided with the system. You should also refer to the installation instructions that came with the rack unit you are using. Identifying the Sections of the Rack Rails You should have received two rack rail assemblies with the SuperServer 6014LT. Each of these assemblies consist of two sections: an inner fixed chassis rail that secures to the unit (A) and an outer fi xed rack rail (B) that secures to the rail brackets. A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail (see Figure 2-1). The A and B rails must be detached from each other to install. To remove the fixed chassis rail (A), pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail assemblies. Figure 2-1. Identifying the Sections of the Rack Rails Mounting Holes B Locking Tab A 2-4 Chapter 2: Server Installation Installing the Chassis Rails Position the fixed chassis rail sections you just removed along the side of the chassis making sure the five screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack. Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. Figure 2-2. Installing Chassis Rails Installing the Rack Rails Determine where you want to place the SuperServer 6014L-T in the rack (see Rack and Server Precautions in Section 2-3). Position the fixed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward. 2-5 SUPERSERVER 6014L-T User's Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3. When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack. Figure 2-3. Installing the Server into a Rack 2-6 Chapter 2: Server Installation Installing the Server into a Telco Rack If you are installing the SuperServer 6014L-T into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accomodate the width of the telco rack. Figure 2-4. Installing the Server into a Telco Rack 2-7 SUPERSERVER 6014L-T User's Manual 2-5 Checking the Serverboard Setup After you install the 6014L-T in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. 1. Accessing the inside of the system (Figure 2-5) First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server. 2. Check the CPUs (processors) You should have one or two processors already installed into the serverboard. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor installation. 3. Check the system memory Your 6014L-T server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5. 4. Installing add-on cards If desired, you can install an add-on card to the system. See Chapter 5 for details on installing a PCI add-on card. 5. Check all cable connections and airflow Make sure all power and data cables are properly connected and not blocking the airflow. See Chapter 5 for details on cable connections. Also, check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the serverboard area of the chassis. 2-8 Chapter 2: Server Installation Figure 2-5. Accessing the Inside of the System 2-9 SUPERSERVER 6014L-T User's Manual 2-6 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the Serial ATA drives and Serial ATA backplane have been properly installed and all essential connections have been made. 1. Accessing the drive bays All drives can be accessed from the front of the server. For servicing the CDROM and floppy drives, you will need to remove the top chassis cover. The Serial ATA disk drives can be installed and removed from the front of the chassis without removing the top chassis cover. 2. Installing a CD-ROM and floppy disk drives Refer to Chapter 6 if you need to reinstall a CD-ROM and/or floppy disk drive to the system. 3. Check the Serial ATA disk drives Depending upon your system's configuration, your system may have one or two Serial ATA drives already installed. If you need to install Serial ATA drives, please refer to the appropriate section in Chapter 6. 4. Check the airflow Airflow is provided by two 10-cm input fans. The system component layout was carefully designed to promote sufficient airflow through the small 1U rackmount space. Also note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans. 5. Supplying power to the system The last thing you must do is to provide input power to the system. Plug the power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS). 2-10 Chapter 3: System Interface Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the Serial ATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take. 3-2 Control Panel Buttons There are two push-button buttons located on the front of the chassis: a reset button and a power on/off button. RESET: The reset switch reboots the system. POWER: This is the main power switch, which is used to apply or turn off the main system power. Turning off system power with this button removes the main power but keeps standby power supplied to the system. 3-1 SUPERSERVER 6014L-T User's Manual 3-3 Control Panel LEDs The control panel located on the front of the chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Overheat/Fan Fail: When this LED flashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain flashing or on as long as the indicated condition exists. 2 NIC2: Indicates network activity on JLAN2 when flashing . 1 NIC1: Indicates network activity on JLAN1 when flashing. HDD: Channel activity for all HDDs. This light indicates CD-ROM and SATA drive activity when flashing. 3-2 Chapter 3: System Interface Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. 3-4 Serial ATA Drive Carrier LED Each Serial ATA drive carrier has a green LED. When illuminated, this green LED (on the front of the Serial ATA drive carrier) indicates drive activity. A connection to the Serial ATA backplane enables this LED to blink on and off when that particular drive is being accessed. 3-3 SUPERSERVER 6014L-T User's Manual Notes 3-4 Chapter 4: System Safety Chapter 4 System Safety 4-1 Electrical Safety Precautions ! Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6014L-T from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system. Do not work alone when working with high voltage components. Power should always be disconnected from the system when removing or installing main system components, such as the serverboard, memory modules and floppy drive. When disconnecting power, you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system. When working around exposed electrical circuits, another person who is familiar with the power-off controls should be nearby to switch off the power if necessary. Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with. Do not use mats designed to decrease static electrical discharge as protection from electrical shock. Instead, use rubber mats that have been specifically designed as electrical insulators. The power supply power cords must include a grounding plug and must be plugged into grounded electrical outlets. 4-1 SUPERSERVER 6014L-T User's Manual Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. CD-ROM Laser: CAUTION - this server may have come equipped with a CDROM drive. To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any unconventional way. 4-2 General Safety Precautions ! Follow these rules to ensure general safety: Keep the area around the SuperServer 6014L-T clean and free of clutter. The SuperServer 6014L-T weighs approximately 23 lbs. (10.5 kg) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs. Place the chassis top cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on. While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan. Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made. 4-2 Chapter 4: System Safety 4-3 ESD Precautions ! Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards. The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD: Use a grounded wrist strap designed to prevent static discharge. Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use. Touch a grounded metal object before removing the board from the antistatic bag. Do not let components or PCBs come into contact with your clothing, which may retain a charge even if you are wearing a wrist strap. Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or contacts. When handling chips or modules, avoid touching their pins. Put the serverboard and peripherals back into their antistatic bags when not in use. For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard. 4-3 SUPERSERVER 6014L-T User's Manual 4-4 Operating Precautions ! Care must be taken to assure that the chassis cover is in place when the 6014L-T is operating to assure proper cooling. Out of warranty damage to the 6014L-T system can occur if this practice is not strictly followed. Figure 4-1. Installing the Onboard Battery LITHIUM BATTERY LITHIUM BATTERY OR BATTERY HOLDER BATTERY HOLDER 4-4 Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors, memory and heatsinks to the X6DLP-EG2 serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system. 5-1 Handling the Serverboard Static electrical discharge can damage electronic components. To prevent damage to printed circuit boards, it is important to handle them very carefully (see Chapter 4). Also note that the size and weight of the serverboard can cause it to bend if handled improperly, which may result in damage. To prevent the serverboard from bending, keep one hand under the center of the board to support it when handling. The following measures are generally sufficient to protect your equipment from static discharge. Precautions • Use a grounded wrist strap designed to prevent static discharge. • Touch a grounded metal object before removing any board from its antistatic bag. • Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts. • When handling chips or modules, avoid touching their pins. • Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use. Unpacking The serverboard is shipped in antistatic packaging to avoid static damage. When unpacking the board, make sure the person handling it is static protected. 5-1 SUPERSERVER 6014L-T User's Manual 5-2 Serverboard Installation This section explains how to mount the X6DLP-EG2 into the SC811LT-260 chassis. Following the steps in the order given will eliminate the most common problems encountered in such an installation. To access the inside of the server, remove the screws from the back lip of the top cover of the chassis, then pull the cover off. Note: Before you install the serverboard you should first attach the heatsink brackets to the back of the serverboard. Installing the Heatsink Brackets 1. Remove the protective film from the heatsink bracket. Remove the protective film 2. Locate the heatsink bracket mounting holes on the reverse side of the serverboard. 3. Align the four pins of the heatsink bracket with the four bracket mounting holes on the back of the serverboard. Heatsink bracket mounting holes 4. Insert the pins of the bracket into the corresponding mounting holes. Gently press the bracket onto the serverboard until it is fully inserted into the holes. Installing the Serverboard Carefully mount the serverboard to the chassis by aligning the board holes with the raised metal standoffs that are visible on the serverboard tray. Insert screws into all the mounting holes on your serverboard that line up with the standoffs and tighten until snug (do not screw them in too tightly). Metal screws provide an electrical contact to the serverboard ground to provide a continuous ground for the system. 5-2 Chapter 5: Advanced Serverboard Setup 5-3 Processor and Heatsink Installation Avoid placing direct pressure to the top of the processor package. Also, never place the serverboard on a conductive ! surface. Always remove the power cord first before adding, removing or changing any hardware components. The X6DLP-EG2 has two 479-pin PGA sockets that support Intel® Xeon® LV or ULV processors. Important: Make sure that you have installed the heatsink bracket(s) to the back of the serverboard first. Tools needed: a flat head screwdriver, a Phillips screwdriver and thermal grease. Installing the Processors 1. Locate the pin 1 locations on the CPU socket and the processor as shown in the pictures. 2. The CPU socket should come in the unlocked position. To unlock the CPU socket, use a flat head screwdriver to turn the lock mechanism counter-clockwise until it cannot turn further. CPU Socket Processor Lock Pin 1 (no hole) 3. Align pin 1 of the processor with the pin 1 corner of the CPU socket. Pin 1 (triangle) Align pin 1 of processor with pin 1 of the CPU socket. 4. Once aligned, lower the processor straight-down and into the socket. ! Warning: Do not brush the processor pins against the surface of the socket or install it at an angle, which may bend or damage the pins. 5-3 SUPERSERVER 6014L-T User's Manual 5. Once the processor is properly seated in the socket, turn the lock mechanism clockwise with the flathead screw driver to lock it. Repeat the above steps if you wish to install a secind processor. Installing the Heatsinks Installed processor 1. Do not apply any thermal grease to the heatsink or the CPU die; the if the required amount has already been applied . 2. Locate the four heatsink mounting holes on the serverboard. Heatsink mounting holes Screw# 1 3. Place the heatsink on top of the processor and insert the heatsink's four pegs into the heatsink mounting holes. Screw# 2 4. Using a Phillips screwdriver, screw in two diagonal screws (i.e. the #1 and the #2 screws) until just snug (do not fully tighten the screws, which may damage the processor.) Repeat the same step to install the remaining two screws. Installed heatsink 5. Repeat the steps above to install another heatsink to the secind processor (if installed). 5-4 Chapter 5: Advanced Serverboard Setup Removing the Heatsink 1. Using a Phillips screwdriver to remove the Screw# 1 heatsink screws from the serverboard (remove diagonal screws first, as show in the picture on the right). Screw# 2 2. Hold the heatsink and gently wriggle the heatsink to loosen it from the processor. (Do not use excessive force when wriggling the heatsink!!) 3. Once the heatsink has been loosened, remove the heatsink from the processor. 4. Clean the surface of the processor and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease before you re-install the processor and the heatsink. 5-5 SUPERSERVER 6014L-T User's Manual 5-4 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back. If you need to disconnect any of these cables, you should take care to keep them routed as they were originally after reconnecting them (make sure the red wires connect to the pin 1 locations). If you are configuring the system, keep the airflow in mind when routing the cables. The following data cables (with their serverboard connector locations noted) should be connected. See the serverboard layout figure in this chapter for connector locations. Serial ATA cables (I-SATA0, I-SATA1) CD-ROM cable (IDE2) Floppy drive cable (J24) Control panel cable (JF1, see next page) Connecting Power Cables The X6DLP-EG2 has a 24-pin primary ATX power supply connector designated "PW1" for connection to the ATX power supply. Connect the appropriate connector from the power supply to the PW1 connector to supply power to the serverboard. The power connector at PW2 must also be connected to your power supply. See the Connector Definitions section in this chapter for power connector pin definitions. 5-6 Chapter 5: Advanced Serverboard Setup Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indicators. Note that even and odd numbered pins are on opposite sides of each header. All JF1 wires have been bundled into single ribbon cable to simplify their connection. Make sure the red wire plugs into pin 1 as marked on the board. The other end connects to the Control Panel printed circuit board, located just behind the system status LEDs in the chassis. See the Connector Definitions section in this chapter for details and pin descriptions of JF1. Figure 5-1. JF1 Header Pins 20 19 Ground NMI x (key) x (key) Power LED Vcc HDD LED Vcc NIC1 Vcc NIC2 Vcc OH/Fan Fail LED Vcc Power Fail LED Vcc Ground Reset Button Ground Power Button 2 5-5 1 I/O Ports The I/O ports are color coded in conformance with the PC 99 specification. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. I/O Ports 5-7 SUPERSERVER 6014L-T User's Manual 5-6 Installing Memory Note: Check the Supermicro web site for recommended memory modules: http:// www.supermicro.com/support/resources/ CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. DIMM Installation (See Figure 5-3) 1. Insert the desired number of DIMMs into the memory slots, starting with DIMM1A and DIMM1B. Pay attention to the notch along the bottom of the module to prevent inserting the module incorrectly. (See support information below.) 2. Gently press down on the memory module until it snaps into place. Repeat to install all DIMMs. Memory Support The X6DLP-EG2 supports up to 16 GB of registered ECC DDR2-400 type SDRAM. The memory scheme is interleaved so you must install two modules at a time. Note: Due to OS limitations, some operating systems may not support more than 4GB of memory.) Figure 5-3. Installing DIMMs DIMM2 Notch To Install: Insert module vertically and press down until it snaps into place. Pay attention to the bottom notch. Release Tab Note: Notches should align with their receptive points on the slot To Remove: Use your thumbs to gently push each release tab outward to free the DIMM from the slot. 5-8 Not Relea Tab Chapter 5: Advanced Serverboard Setup 5-7 Adding PCI Cards 1. PCI slots The 6014L-T system includes a CSE-RR1U-X riser card. This riser fits into a 66 MHz PCI slot to support a full-height, half-length PCI add-on card. There is also the option of using the (optional) CSE-RR1U-EL riser card to support the use of an expansion card in the x8 PCI-Express slot. 2. PCI card installation Before installing a PCI add-on card, see step 1, above. Begin by swinging out the release tab on the appropriate PCI slot shield. Insert the PCI card into the riser card, pushing down with your thumbs evenly on both sides of the card. Finish by pushing the release tab back to its original (locked) position. 5-9 SUPERSERVER 6014L-T User's Manual 5-8 Serverboard Details Figure 5-4. SUPER X6DLP-EG2 Layout (not drawn to scale) PW1 Keyboard/ Mouse PW4 PW3 PW2 CPU FAN1 J43 JPR1 USB0/1 DIMM1B CPU 1 COM1 DIMM1A DIMM2B DIMM2A DIMM3B VGA DIMM3A DIMM4B DIMM4A JLAN1 Battery CPU2 JF1 E7520 JLAN2 MCH North Bridge FAN6 JPL1 JPL2 FAN5 JWOL CPU FAN2 8x PCI-Express Slot6: PCI-X 66 MHz (ZCR) JF2 FAN3 Slot5: PCI-X 66 MHz JP15 JP13 Speaker JWD Slot4: 8x PCI-Express DS9 COM2 IDE1 IPMI BIOS 6300 ESB Rage XL ICH South Bridge JWOR JPG1 JL1 JBT1 FAN4 Slot1: PCI 33 MHz I-SATA0 Printer Floppy I-SATA1 IDE2 Notes: Jumpers not indicated are for test purposes only. 5-10 USB2/3 Chapter 5: Advanced Serverboard Setup X6DLP-EG2 Quick Reference Jumper Description Default Setting J13/J15 PCI/PCI-X Slots to System SMB Open (Disabled) JBT1 CMOS Clear See Section 5-9 JPF JPG1 Power Force On VGA Enable Open (Disabled) Pins 1-2 (Enabled) JPL1/JPL2 JLAN1/JLAN 2 Enable/Disable Pins 1-2 (Enabled) JPR1 Power Fail Alarm Reset Open (Disabled) JWD Watch Dog Enable Pins 1-2 (Enabled) Connector Description COM1/COM2 FAN 1-6 Floppy IDE1/IDE2 IPMI I-SATA0/1 JF1 JF2 JL1 JLAN 1/2 JWOL JWOR Keyboard/Mouse Printer PW1 PW2 PW3 PW4 USB0/1 USB2/3 VGA COM1/COM2 Serial Port Connector/Header CPU/Chassis Fan Headers Floppy Disk Drive Connector IDE1/2 Hard Disk Drive Connectors IPMI 2.0 Socket Serial ATA0, Serial ATA1 Connectors Front Control Panel Connector PWR LED (Pins1-3), Speaker (Pins 5-7) Chassis Intrusion Header G-bit Ethernet Ports Wake-on-LAN Header Wake-on-Ring Header Keyboard and Mouse Ports Parallel (Printer Port) Header Primary 24-pin ATX PWR Connector 12V 8-pin PWR Connector Power SMB (System Management Bus) PWR Fault Universal Serial Bus Ports Universal Serial Bus Headers VGA Connector Onboard Indicators Description DS1, DS5 DS7-DS8 DS9 Power LED Indicators POST Code LEDs (*See Section 5- & App.A) System Status LED 5-11 SUPERSERVER 6014L-T User's Manual 5-9 Connector Definitions ATX Power 24-pin Connector Pin Definitions (PW1) ATX Power Connector The main power supply connector on the X6DPL-EG2 meets the SSI EPS 12V specification. See the table on the right for pin definitions. Note: You must also connect the processor power connector (PW2, below.) Pin# Definition Pin # Definition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 COM 16 PS_ON 4 +5V 17 COM 5 COM 18 COM 6 +5V 19 COM 7 COM 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 11 +12V 24 COM 12 +3.3V Processor Power Connector In addition to the Primary ATX power connector (above), the 12V processor power connector at PW2 must also be connected to your power supply to provide adequate power to the system. NMI Button Secondary Power Connector Pin Definitions (PW2) Pins Definition 1 through 4 Ground 5 through 8 +12V NMI Button Pin Definitions (JF1) The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin definitions. Power LED Pin# Definition 19 Control 20 Ground Power LED Pin Definitions (JF1) The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for pin definitions. 5-12 Pin# Definition 15 Vcc 16 Control Chapter 5: Advanced Serverboard Setup HDD LED HDD LED Pin Definitions (JF1) The HDD LED (for IDE and SATA Pin# Definition drives) connection is located on pins 13 Vcc 13 and 14 of JF1. Attach the drive LED cable to these pins to display disk 14 HD Active activity. See the table on the right for pin definitions. NIC1/2 LEDs NIC1/2 LED Pin Definitions (JF1) The NIC (Network Interface Controller) LED connections for JLAN1 are located on pins 11 and 12 of JF1 and the NIC LED connections for JLAN2 are located on pins 9 and 10 of JF1. Attach the NIC cables to display network activity. Refer to the table on the right for pin definitions. Overheat/Fan Fail LED Pin# Definition 9/11 Vcc 10/12 Ground OH/Fan Fail LED Pin Definitions (JF1) Connect an LED to the OH/Fan Fail connection on pins 7 and 8 of JF1 to provide warning of system overheating or system fan failure. The LED will flash/stay on as long as the fan fail/overheat condition exists. Refer to the table on the right for pin definitions and Chapter 3 for details. Power Fail LED Pin# Definition 7 Vcc 8 Ground Power Fail LED Pin Definitions (JF1) The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions. 5-13 Pin# Definition 5 Vcc 6 Ground SUPERSERVER 6014L-T User's Manual Reset Button The Reset Button connection is lo- Reset Button Pin Definitions (JF1) cated on pins 3 and 4 of JF1. Attach Pin# Definition it to the hardware reset switch on the computer case. Refer to the table on 3 Reset 4 Ground the right for pin definitions. Power Button Power Button Pin Definitions (JF1) The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (see setting in BIOS). To turn off power in suspend mode, depress the button for at least 4 seconds. Pin# Definition 1 PW_ON 2 Ground JLAN1/2 (Ethernet Ports) Two gigabit Ethernet ports are located beside the VGA port. These ports accept RJ45 type cables. Chassis Intrusion Chassis Intrusion Pin Definitions (JL1) A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion. 5-14 Pin# Definition 1 Intrusion Input 2 Ground Chapter 5: Advanced Serverboard Setup Universal Serial Bus (USB0/1) Universal Serial Bus Pin Definitions (USB0/1) Two USB 2.0 ports are located beside the LAN ports. USB0 is the bottom port and USB1 is the top port. See the table on the right for pin definitions. USB0 Pin # Definition USB1 Pin # Definition 1 +5V 1 +5V 2 PO- 2 PO- 3 PO+ 3 PO+ 4 Ground 4 Ground 5 N/A 5 Key Universal Serial Bus Headers USB Headers Pin Definitions (USB2/3) Two extra USB headers designated USB2/3 can be used for front side USB access. You will need a USB cable to use these connections. Refer to the table on the right for pin definitions. USB2 Pin # Definition USB3 Pin # Definition 1 +5V 1 +5V 2 PO- 2 PO- 3 PO+ 3 PO+ 4 Ground 4 Ground 5 N/A 5 N/A Fan Headers There are six fan headers (Fan1 - Fan 6) on the X6DLP-EG2. Fan1 and Fan 2 are for the CPU fans and Fan3 to Fan6 are system cooling fans. See the table on the right for pin definitions. Note: These fan headers are 4-pin fans. Pins 1-3 are backward compatible with traditional 3-pin fans. Please refer to "Health Monitoring" in the BIOS Advanced Settings for fan speed control settings. 5-15 Fan Header Pin Definitions (Fan1-5) Pin# Definition 1 Ground (Black) 2 +12V (Red) 3 Tachometer 4 PWM_Control SUPERSERVER 6014L-T User's Manual Speaker/Power LED/Keylock Speaker Connection Pin Definitions On the JF2 header, pins 1, 3, 5 and 1 Red Wire, Speaker Data 7 are for the speaker, pins 2, 4 and 6 3 No Connection are for the power LED and pins 8 and 10 are for the keylock. Pin 9 is absent 5 Key 7 Speaker Data (key). See the table on the right for PWR LED/Keylock Connection Pin Definitions speaker pin definitions. Note: The speaker connector pins are for use with an external speaker. If you wish to use the onboard speaker, you should close pins 5-7 with a jumper. 2 +Vcc 4 -Vcc 6 -Vcc 8 Keylock 10 Keylock Wake-On-Ring The Wake-On-Ring header is designated JWOR. This function allows your computer to receive and "wakeup" by an incoming call to the modem when in suspend state. See the table on the right for pin definitions. You must have a Wake-On-Ring card and cable to use this feature. Wake-On-Ring Pin Definitions (JWOR) Pin# Definition 1 Ground (Black) 2 Wake-up Wake-On-LAN The Wake-On-LAN (JWOL) header is designated JWOR. See the table on the right for pin definitions. You must enable the LAN Wake-Up function in the BIOS and also have a LAN card with a Wake-on-LAN connector and cable to use this feature. 5-16 Wake-On-LAN Pin Definitions (JWOL) Pin# Definition 1 +5V Standby 2 Ground 3 Wake-up Chapter 5: Advanced Serverboard Setup Power Fault PWR Fault Connection Pin Definitions (PW4) Connect a cable from your power supply to the PW4 header to provide Pin# Definition warning of power supply failure. This warning signal is passed through the 1 PWR 1 Fail Signal 2 PWR 2 Fail Signal PWR_LED pin to indicate of a power 3 PWR 3 Fail Signal failure on the chassis. See the table 4 PWR 4 Fail Signal on the right for pin definitions. Note: This feature is only available when using redundant Supermicro power supplies. ATX PS/2 Keyboard and PS/2 Mouse Ports PS/2 Keyboard and Mouse Port Pin Definitions The ATX PS/2 keyboard and PS/2 mouse ports are located beside the USB ports. See the table at right for pin definitions. SMB Power (I2 C) Pin# Definition 1 Data 2 NC 3 Ground 4 VCC 5 Clock 6 NC SMB Power Connection Pin Definitions (PW3) Connector The I2C connector (PW3) allows you to monitor the status of the power supply, fans and system temperature. Pin# Definition 1 Clock 2 Data 3 N/A 4 N/A 5 N/A Serial Port Pin Definitions (COM1/COM2) Serial Ports Pin # One backpanel COM port and one COM header (located near the BIOS chip) are included on the serverboard. See the table on the right for pin definitions. Definition Pin # Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC Note: Pin 10 is included on the header but not on the port. NC indicates no connection. 5-17 SUPERSERVER 6014L-T User's Manual 5-10 Jumper Settings Explanation of Jumpers To modify the operation of the 3 2 1 3 2 1 Connector Pins serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two Jumper pins to change the function of the connector. Pin 1 is identified with a Setting square solder pad on the printed circuit board. See the serverboard layout pages for jumper locations. Note: On two pin jumpers, "Closed" means the jumper is on and "Open" means the jumper is off the pins. CMOS Clear JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To clear CMOS, 1) First power down the system and unplug the power cord(s) 2) With the power disconnected, short the CMOS pads with a metal object such as a small screwdriver 3) Remove the screwdriver (or shorting device) 4) Reconnect the power cord(s) and power on the system. Note: Do not use the PW_ON connector to clear CMOS. JLAN1/2 Enable/Disable JLAN Enable/Disable Jumper Settings (JPL1, JPL2) Change the setting of jumper JPL1 and JPL2 to enable or disable the JLAN1 and JLAN2 ports, respectively . See the table on the right for jumper settings. The default setting is enabled 5-18 Jumper Setting Definition Pins 1-2 Enabled Pins 2-3 Disabled Chapter 5: Advanced Serverboard Setup VGA Enable/Disable VGA Enable/Disable Jumper Settings (JPG1) Jumper Setting JPG1 enables or disables the VGA Definition port on the serverboard. See the table Pins 1-2 Enabled on the right for jumper settings. Pins 2-3 Disabled SMBus to PCI Slots SMBus to PCI Jumper Settings (J13, J15) Jumpers J13 and J15 allow you to connect the PCI-X/PCI slots to the System Jumper Setting Management Bus. The default setting is open to disable the connection. See the table on the right for jumper settings. Closed Enabled Open Disabled Definition Power Force On Power Force-On Jumper Settings (JPF) Jumper JPF allows you to enable or disable the Power Force-On function. If enabled, power will always stay on automatically. If disabled (the default setting), the user must press the power button to power on the system. Jumper Setting Definition Open Disabled Closed Force Pwr On Watch Dog JWD controls Watch Dog, a system monitor that takes action when a software application freezes the system. Jumping pins 1-2 will cause WD to reset the system if an application is hung up. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that is hung up. See the table on the right for jumper settings. Watch Dog can also be enabled via BIOS. Note: When enabled, the user needs to write their own application software to disable the Watch Dog Timer. 5-19 Watch Dog Jumper Settings (JWD) Jumper Setting Definition Pins 1-2 Reset Pins 2-3 NMI Open Disabled SUPERSERVER 6014L-T User's Manual Alarm Reset The system will notify you in the event of Alarm Reset Jumper Settings a power supply failure. This feature assumes that Supermicro redundant power supply units are installed in the chassis. Jumper Setting Open Enabled If you only have a single power supply Closed Disabled Definition installed, you should not connect anything to this header (JPR1) to prevent false alarms. See the table on the right for jumper settings. 5-11 Onboard Indicators JLAN Left LED (Connection Speed Indicator) JLAN LEDs The Gigabit Ethernet LAN ports (located beside the USB ports) each have two LEDs. The right LED indicates activity while the left LED may be green, amber or off to indicate the speed of the connection. See table at right for the functions associated with the connection speed LED. System Status LED DS9 is an onboard indicator that informs you of the system power status. Refer to table on the right for information. Please refer to Appendix A for more information. 5-20 LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz System Status LED Indicator (DS9) DS9 Definition Green System: On, Normal Amber System: Off, PWR Cable Connected Red PWR or CPU Failure, CPU Overheat Chapter 5: Advanced Serverboard Setup Onboard LED Indicators (DS1, DS5) LED Indicators (DS1, DS5) DS1 and DS5 are additional LED DS# Definition (when illuminated) DS1 CPU PWR bad or processor power cable not connected DS5 Power present on serverboard indicators on the X6DLP-EG2. See the table on the right for information regarding these two LEDs. Onboard LED Indicators (DS7, DS8) DS7 and DS8 are POST code LEDs. Please refer to Appendix A for POST code information. 5-21 SUPERSERVER 6014L-T User's Manual 5-12 Parallel Port, Floppy, IDE and SATA Drive Connections Note the following when connecting the floppy and hard disk drive cables: • The floppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1. • A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives. The connector with twisted wires always connects to drive A, and the connector that does not have twisted wires always connects to drive B. Parallel (Printer) Port Connector Pin Definitions (Printer) Parallel (Printer) Port Header The parallel (printer) port is located beside the floppy drive connection. See the table on the right for pin definitions. 5-22 Pin# Definition Pin # Definition 1 Strobe- 2 Auto Feed- 3 Data Bit 0 4 Error- 5 Data Bit 1 6 Init- 7 Data Bit 2 8 SLCT IN- 9 Data Bit 3 10 GND 11 Data Bit 4 12 GND 13 Data Bit 5 14 GND 15 Data Bit 6 16 GND 17 Data Bit 7 18 GND 19 ACK 20 GND 21 BUSY 22 Write Data 23 PE 24 Write Gate 25 SLCT 26 NC Chapter 5: Advanced Serverboard Setup Floppy Connector Floppy Drive Connector Pin Definitions (Floppy) The floppy connector is des- Pin# Definition ignated "Floppy". See the 1 Ground 2 FDHDIN table to the right for pin definitions. 3 Ground 4 Reserved 5 Key 6 FDEDIN 7 Ground 8 Index 9 Ground 10 Motor Enable 11 Ground 12 Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable 17 Ground 18 DIR 19 Ground 20 STEP 21 Ground 22 Write Data 23 Ground 24 Write Gate 25 Ground 26 Track 00 27 Ground 28 Write Protect 29 Ground 30 Read Data 31 Ground 32 Side 1 Select 33 Ground 34 Diskette Pin # Definition SATA Connector Pin Definitions (I-SATA0, I-SATA1) SATA Connectors There are no jumpers to configure the onboard SATA connectors. See the table on the right for pin definitions. 5-23 Pin # Definition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SUPERSERVER 6014L-T User's Manual IDE Connectors There are no jumpers to configure the onboard IDE connectors. See the table below for pin definitions. IDE Drive Connectors Pin Definitions (IDE1, IDE2) Pin# Definition Pin # 1 Reset IDE 2 Ground 3 Host Data 7 4 Host Data 8 5 Host Data 6 6 Host Data 9 7 Host Data 5 8 Host Data 10 9 Host Data 4 10 Host Data 11 11 Host Data 3 12 Host Data 12 13 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17 Host Data 0 18 Host Data 15 19 Ground 20 Key 21 DRQ3 22 Ground 23 I/O Write 24 Ground 25 I/O Read 26 Ground 27 IOCHRDY 28 BALE 29 DACK3 30 Ground 31 IRQ14 32 IOCS16 33 Addr1 34 Ground 35 Addr0 36 Addr2 37 Chip Select 0 38 Chip Select 1 39 Activity 40 Ground 5-24 Definition Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC811LT-260 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If a step is unnecessary, skip ahead to the step that follows. Tools Required The only tool you will need to install components and perform maintainance is a Philips screwdriver. 6-1 Static-Sensitive Devices Electric Static Discharge (ESD) can damage electronic components. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully. The following measures are generally sufficient to protect your equipment from ESD discharge. Precautions Use a grounded wrist strap designed to prevent static discharge. Touch a grounded metal object before removing any board from its antistatic bag. Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts. When handling chips or modules, avoid touching their pins. Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use. For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard. Unpacking The serverboard is shipped in antistatic packaging to avoid static damage. When unpacking the board, make sure the person handling it is static protected. 6-1 SUPERSERVER 6014L-T User's Manual Figure 6-1. Chassis Front View Figure 6-2. Chassis Rear View 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system control buttons and status indicators. These wires have been bundled together in a ribbon cable to simplify the connection. Connect the cable from JF1 on the serverboard to the correct neader on the Control Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both headers. Pull all excess cabling out of the airflow path. The LEDs inform you of system status. See Chapter 3 for details on the LEDs and the control panel buttons. Details on JF1 can be found in Chapter 5. 6-2 Chapter 6: Advanced Chassis Setup 6-3 System Fans Two 4-cm fans provide the cooling for the SuperServer 6014L-T. Air seals are used at the chassis cross section, which separates the drive bay area from the serverboard area of the chassis to promote better airflow. It is highly important that the air seal is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis. The fans can adjust their speed according to the heat level sensed in the system, which results in more efficient and quieter fan operation. Fan speed is controlled by a setting in BIOS (see Chapter 7). System Fan Failure If a fan fails, you will need to have it replaced with the same type. Contact your vendor or Supermicro for information on replacement fans. 6-4 Drive Bay Installation/Removal Accessing the Drive Bays Serial ATA Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace Serial ATA drives. Proceed to the next step for instructions. CD-ROM/Floppy Disk Drives: For installing/removing a CD-ROM or floppy disk drive, you will need to gain access to the inside of the 6014L-T by removing the top cover of the chassis. Proceed to the "CD-ROM and Floppy Drive Installation" section later in this chapter for instructions. Note: Only a "slim" CD-ROM drive will fit into the 6014L-T. 6-3 SUPERSERVER 6014L-T User's Manual Serial ATA Drive Installation 1. Mounting a Serial ATA drive in a drive carrier The Serial ATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the Serial ATA drive bays. For this reason, even empty carriers without Serial ATA drives installed must remain in the chassis. To add a new Serial ATA drive, install a drive into the carrier with the printed circuit board side toward the carrier so that the mounting holes align with those in the carrier. Secure the drive to the carrier with four screws, as shown in Figure 6-3. Figure 6-3. Mounting a Drive in a Carrier ! ! Use caution when working around the Serial ATA backplane. Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper airflow. Important: Regardless of how many Serial ATA hard drives are installed, both drive carriers must remain in the drive bays to maintain proper airflow. 6-4 Chapter 6: Advanced Chassis Setup 2. Installing/removing hot-swap Serial ATA drives Two Serial ATA drive bays are located in the front of the chassis, making them easily accessible for installation and removal. These drives are hot-swappable, meaning they can be installed and removed without powering down the system. To remove, first push the release button located beside the drive LEDs, then swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-4). Figure 6-4. Removing/Installing Serial ATA Drives ! Important: Regardless of how many Serial ATA drives are installed, both drive carriers must remain in the drive bays to maintain proper airflow. 6-5 SUPERSERVER 6014L-T User's Manual Serial ATA Backplane The Serial ATA drives plug into a backplane that provides power, drive ID and bus termination. A RAID controller can be used with the backplane to provide data security. The operating system you use must have RAID support to enable the hot-swap capability of the Serial ATA drives. The backplane has two jumpers as follows: JP18: Alarm reset JP25: Hard drive temperature threshold Settings: Open = 45º, Pins 1-2 = 50º, Pins 2-3 = 55º. CD-ROM and Floppy Drive Installation The top cover of the chassis must be opened to gain full access to both drives. The CD-ROM drive must have a "slim" profile to fit into the 6014L-T. You must power down the system before installing or removing a CD-ROM or floppy drive. First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server. To install either type of drive, start by disconnecting the drives' power and data cables then remove the two screws from either side of the bracket the secures the drives to the chassis. With these screws removed, you can then lift out the entire assembly (drives and bracket). Both the CD-ROM and the floppy drives are each secured to this bracket with four screws (two on either side). Remove these screws to take out the drive then install a new drive into the same space. Secure it to the bracket with the four screws. Then place the assembly back into place and secure it to the chassis with the two screws previously removed. Finish by reconnecting the drves' power and data cables. Drives mount on rails and should "click" into place to be correctly and fully installed in their bays. • A red mark on a wire typically designates the location of pin 1. 6-6 Chapter 6: Advanced Chassis Setup 6-5 Power Supply The SuperServer 6014L-T has a single 260 watt power supply. This power supply has the capability of operating at 100 or 240 input volts. Depress the main power button on the front of the chassis and then unplug the AC power cord to completely remove power from the system before removing the power supply. Power Supply Failure If the power supply unit fails, the system will shut down and you will need to replace the power supply unit. Replacement units can be ordered directly from Supermicro (PWS-0055 - see contact infomation in Chapter 1). Replacing the Power Supply 1. Accessing the inside of the SuperServer 6014L-T To replace a power supply, you must first remove the top chassis cover. To do so, first release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover and push it away from you. You can then lift the top cover from the chassis to gain full access to the inside of the server. 2. Removing the power supply First unplug the power cord from the system. To remove the failed power unit, remove the two screws on the back of the power supply, which secure it to the chassis. You can then lift the unit straight out of the chassis. (The power cord should have already been removed.) 3. Installing a new power supply Replace the failed unit with another unit of the same wattage. It is highly recommended to replace it with the exact same power supply. Carefully insert the new unit into position in the chassis and secure it with the two screws at the rear of the unit. Before reconnecting the power cord, make sure the power switch on the power supply is in the off position. Then reconnect the power cord, replace the chassis top cover and push the unit back into the rack. Finish by turning the power switch on the power supply on, and then depress the power button on the front of the system. 6-7 SUPERSERVER 6014L-T User's Manual Notes 6-8 Chapter 7: BIOS Chapter 7 BIOS 7-1 Introduction This chapter describes the AMIBIOS Setup Utility for the X6DLP-EG2. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily upgraded using a floppy disk-based program. This chapter describes the basic navigation of the AMIBIOS Setup Utility setup screens. Starting the BIOS Setup Utility To enter the AMIBIOS Setup Utility screens, hit the <Delete> key while the system is booting up. Each main BIOS menu option is described in this user’s guide. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be configured. “Grayed-out” options cannot be configured while options in blue can be configured by the user. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: AMI BIOS has default text messages built-in. Supermicro retains the option to include, omit, or change any of these text messages.) The AMIBIOS Setup Utility uses a key-based navigation system (hot keys). Most of these hot keys can be used at any time during the setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, arrow keys, and Esc. Options printed in Bold are the default settings. How To Change the Configuration Data The configuration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate time during system boot. Normally, the only visible POST (Power On Self Test) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens. An AMIBIOS identification string is displayed at the left bottom corner of the screen, below the copyright message. Warning!! To prevent a possible boot failure, do not shut down or reset the system while updating BIOS.. 7-1 SUPERSERVER 6014L-T User's Manual 7-2 Main Setup When you first enter the AMI BIOS Setup Utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below. When you select the Main Setup, the following items will be automatically displayed: System Overview: The following BIOS information will be displayed: AMIBIOS Version Build Date ID Processors When you select this option, the AMI BIOS will automatically display the status of processors as shown below: Type Speed Counts System Memory This option allows the AMI BIOS to display the status of memory installed in the system. 7-2 Chapter 7: BIOS System Time/System Date Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard. Press the <Tab> key or the arrow keys to move between fields. The date must be entered in DAY/MM/DD/YY format. The time is entered in HH:MM:SS format.(*Note: The time is in 24-hour format. For example, 5:30 A.M. appears as 05:30:00, and 5:30P. M. as 17:30:00.) 7-3 Advanced Settings The Advanced Settings screen and sub menus are listed below: Warning When you first enter the Advanced Setup screen, the Setup Warning will be displayed. Please follow the instruction and set the correct value for each item to prevent the system from malfunctioning. CPU Configuration Sub-Menu Configure Advanced CPU Settings This option allows the user to configure the Advanced CPU settings for the processor(s) installed in the system. 7-3 SUPERSERVER 6014L-T User's Manual Execute Disable Bit (Available when supported by the OS and the CPU.) Set to Enabled to enable the Execute Disable Bit to allow the processor to classify areas in the system memory where an application code can and cannot execute, thus preventing a worm or a virus from creating a flood of codes to overwhelm the processor or damage the system during an attack. (For more information regarding hardware/software support for this function, please refer to Intel's and Microsoft's web sites. Core Multi-Processing (Available when supported by the CPU.) Select Enabled to enable the function of multiple CPU core processing. if Disabled, one CPU execution core will be disabled. CPU TM Function (Available when supported by the CPU.) This feature allows the user to activate the CPU thermal monitor mechanism. TM1 allows the CPU to regulate its power consumption based upon the modulation of the CPU Internal clock when the CPU temperature reaches a pre-defined overheat threshold. The options are Disabled and Enabled. (Select Enabled to allow the CPU to reduce its power consumption by lowering the CPU frequency and the CPU voltage when the CPU temperature reaches a pre-defined overheat threshold.) TM2 is available only when it is supported by the CPU. IDE Configuration Sub-Menu IDE Configuration This feature allows the user to configure the IDE mode. The options are Disabled, P-ATA (Parallel ATA) only, S-ATA (Serial ATA) only and P-ATA & S-ATA. Combined Mode Operation This feature allows the user to select the IDE Combined Mode. The options are P-ATA 1st Channel and S-ATA 1st Channel. S-ATA Ports Definition This feature allows the user to configure the Serial ATA Ports. The options are P0-Master/P1-Slave and P0-Slave/P1-Master. Primary IDE Channel Master/Slave, Secondary IDE Channel Master/ Slave, Third IDE Master/Slave, Fourth IDE Channel Master/Slave These settings allow the user to set the parameters of Primary IDE Channel Master/ Slave, Secondary IDE Channel Master/Slave, Third IDE Master/Slave, Fourth IDE Channel Master/Slave slots. Hit <Enter> to activate the following sub-menu screen for detailed options of these items. Set the correct configurations accordingly. 7-4 Chapter 7: BIOS Type Select the type of device connected to the system. The options are Not Installed, Auto, CDROM and ARMD. LBA/Large Mode LBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities over 137 GB, your system must be equipped with a 48-bit LBA mode addressing. If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled and Auto. Block (Multi-Sector Transfer) Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select "Disabled" to allow the data to be transferred from and to the device one sector at a time. Select "Auto" to allows the data transfer from and to the device occur multiple sectors at a time if the device supports it. The options are Auto and Disabled. PIO Mode The IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4. Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be determined. Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs. Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs. Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate of 8.3 MBs. Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate of 11.1 MBs. Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer rate of 16.6 MBs. This setting generally works with all hard disk drives manufactured after 1999. For other disk drives, such as IDE CD-ROM drives, check the specifications of the drive. S.M.A.R.T. For Hard disk drives Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive failures. Select "Auto" to allow the AMI BIOS to auto detect hard disk drive support. Select "Disabled" to prevent the AMI BIOS from using the S.M.A.R.T. Select "Enabled" to allow the AMI BIOS to use the S.M.A.R.T. to support hard drive disk. The options are Disabled, Enabled, and Auto. 7-5 SUPERSERVER 6014L-T User's Manual 32Bit Data Transfer Select "Enabled" to activate the 32-bit data transfer function. Select "Disabled" to disable this function. The options are Enabled and Disabled. Hard Disk Write Protect Select Enabled to enable the function of Hard Disk Write Protect to prevent data from being written to HDD. The options are Enabled or Disabled. IDE Detect Time Out This feature allows the user to set the time-out value for detecting ATA and ATAPI devices installed in the system. The options are 0 (sec), 5, Mode 1.0, 15, 20, 25, 30, and 35. ATA(PI) 80Pin Cable Detection This feature allows the AMI BIOS to auto-detect 80-pin ATA(PI) cables. The options are Host & Device, Host and Device. Floppy Configuration This option allows the user to configure the settings for the floppy drives installed in the system. Floppy A Move the cursor to these fields via up and down arrow keys to select the floppy type. The options are Disabled, 360 KB 5 1/4", 1.2 MB 5 1/4", 720 KB 3½", 1.44 MB 3½”, and 2.88 MB 3½". OnBoard Floppy Controller Select "Enabled" to enable the onboard floppy controller. The options are Disabled and Enabled. PCI/PnP Configuration Plug & Play OS Select Yes to allow the OS to configure Plug & Play devices. (This is not required for system boot if you system has an OS that supports Plug & Play.) Select No to allow the AMI BIOS to configure all devices in the system. PCI Latency Timer This option sets the latency of all PCI devices on the PCI bus. The default setting is "64." Select "32" to set the PCI latency to 32 PCI clock cycles. Select "64" to set the PCI latency to 64 PCI clock cycles. Select "96" to set the PCI latency to 7-6 Chapter 7: BIOS 96 PCI clock cycles. Select "128" to set the PCI latency to 128 PCI clock cycles. Select "160" to set the PCI latency to 160 PCI clock cycles. Select "192" to set the PCI latency to 192 PCI clock cycles. Select "224" to set the PCI latency to 224 PCI clock cycles. Select "248" to set the PCI latency to 248 PCI clock cycles. Allocate IRQ to PCI VGA Set this value to allow or restrict the system from giving the VGA adapter card an interrupt address. The options are Yes and No. Palette Snooping Select Enabled to inform the PCI devices that an ISA graphics device is installed in the system in order for the graphics card to function properly. The options are Enabled and Disabled. PCI IDE BusMaster Set this value to allow or prevent the use of PCI IDE busmastering. Select "Enabled" to allow the BIOS to use the PCI busmaster for reading and writing to IDE drives. The options are Disabled and Enabled. Offboard PCI/ISA IDE Card This option allows the user to assign a PCI slot number to an off-board PCI/ISA IDE card in order for it to function properly. The options are Auto, PCI Slot1, PCI Slot2, PCI Slot3, PCI Slot4, PCI Slot5, and PCI Slot6. IRQ3/IRQ4/IRQ5/IRQ7/IRQ9/IRQ10/IRQ11/IRQ14/IRQ15 This feature specifies the availability of an IRQ to be used by a PCI, PnP device. Select Reserved for an IRQ to be used by a Legacy ISA device. The options are Available and Reserved. DMA Channel 0/Channel 1/Channel 3/Channel 5/Channel 6/Channel 7 Select Available to indicate that a specific DMA channel is available to be used by a PCI/PnP device. Select Reserved if a DMA channel specified is reserved for a Legacy ISA device. Reserved Memory Size This feature specifies the size of memory block to be reserved for Legacy ISA devices. The options are Disabled, 16K, 32K, 64K. 7-7 SUPERSERVER 6014L-T User's Manual Super IO Configuration Sub-Menu Serial Port1 Address This option specifies the base I/O port address and the Interrupt Request address of Serial Port 1. Select "Disabled" to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port physically becomes unavailable. Select "3F8/IRQ4" to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address. The options are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3. Serial Port2 Address This option specifies the base I/O port address and the Interrupt Request address of Serial Port 2. Select "Disabled" to prevent the serial port from accessing any system resources. When this option is set to "Disabled", the serial port physically becomes unavailable. Select "2F8/IRQ3" to allow the serial port to use 2F8 as its I/O port address and IRQ 3 for the interrupt address. The options are Disabled, 2F8/IRQ3, 3E8/IRQ4 and 2E8/IRQ3. Parallel Port Address This option specifies the I/O address used by the parallel port. Select Disabled to prevent the parallel port from accessing any system resources. When the value of this option is set to Disabled, the printer port becomes unavailable. Select 378 to allow the parallel port to use 378 as its I/O port address. The majority of parallel ports on computer systems use IRQ7 and I/O Port 378H as the standard setting. Select 278 to allow the parallel port to use 278 as its I/O port address. Select 3BC to allow the parallel port to use 3BC as its I/O port address. Parallel Port Mode This feature allows the user to specify the parallel port mode. The options are Normal, Bi-Directional, EPP and ECP. ECP Mode DMA Channel This feature allows the BIOS to select the ECP DMA mode for the parallel port. The options are DMA0, DMA1 and DMA3. Parallel Port IRQ This feature allows the user to select the IRQ (interrupt request) for the parallel port. The options are IRQ5 and IRQ7. 7-8 Chapter 7: BIOS Advanced Chipset Settings This item allows the user to configure the Advanced Chipset settings for the system. NorthBridge Configuration This feature allows the user to configure the settings for the Intel E7520 NorthBridge chipset. Memory Remap Feature Select Enabled to allow remapping of the overlapped PCI memory above the total physical memory. The options are Enabled and Disabled. Memory Mirroring/Sparing This feature allows the user to enable the function of Memory Mirroring and Sparing if memory configuration supports this function. The options are Disabled and Sparing. DMA Controller This feature allows the user to enable or disable DMA Controller. The options are Disabled and Enabled. SouthBridge Configuration This feature allows the user to configure the settings for the Intel ICH SouthBridge chipset. CPU B.I.S.T. Enable Select Enabled to enable the function of CPU Built In Self Test. The options are Enabled and Disabled. ICH Delayed Transaction Select Disabled to set the South Bridge P2P Bridge Secondary Discard Timer to 32 micro-seconds for the PCI 32-bit bus. Select Enabled to set the South Bridge P2P Bridge Secondary Discard Timer to 4 micro-seconds for the PCI 32-bit bus. ICH DCB Select Enabled to activate the ICH DMA Collection Buffer to provide Type-F DMA performance for all DMA channels, allowing the DMA controllers located in the FPGA to move data between the CPU memory and the coprocessor. It is ideal for systems whose CPU main memory can be directly accessed from the FPGA. 7-9 SUPERSERVER 6014L-T User's Manual APCI Configuration This item allows the user to enable or disable the ACPI support for the operating system. ACPI Configuration Use this feature to configure additional ACPI options. Select Yes if the operating system supports ACPI. Select No if the operating system does not support ACPI. The options are No and Yes. ACPI 2.0 Features Select Yes to allow the RSDP pointers to point to the Fixed System Description Tables. Select No to deactivate this function. The options are Yes and No. ACPI APIC Support Select Enabled to allow the ACPI APIC Table Pointer to be included in the RSDP pointer list. The options are Enable and Disabled. AMI OEMB Table Select Enabled to allow the OEMB Table Pointer to be included in the R(x)SDT pointer lists. The options are Enabled and Disabled. Headless Mode Select Enabled to activate the Headless Operation Mode through the ACPI and will allow the BIOS to boot up the system without any keyboard, mouse and video. The options are Enabled and Disabled. Power Configuration This feature allows the user to configure PnP settings. Power Button If set to Instant-Off, the system will power off immediately as soon as the user hits the power button. If set to 4-sec., the system will power off when the user presses the power button for 4 seconds or longer. The options are Instant-Off and 4-sec override. Restore on AC Power Loss This setting allows the user to decide how the system will react when power returns after an unexpected loss of power. The options are Stay Off, Power On and Last State. 7-10 Chapter 7: BIOS Watch Dog Timer This setting is used to activate and de-activate the Watch Dog Timer. It must be used in conjunction with the WD jumper (see Chapter 2 for details). The options are Disabled and Enabled. Event Log Configuration Highlight this item and press <Enter> to view the contents of the event log. View Event Log This feature allows the user to view all unread events. Mark All Events as Read Highlight this item and press <Enter> to mark the DMI events as read. Clear Event Log This setting will clear all event logs when set to OK. The options are OK and Cancel. ECC Event Logging This setting allows you to enable or disable the function of ECC Event logging. The options are Enabled or Disabled. Hub Interface Event Logging This setting allows you to enable or disable the function of Hub Interface Event logging. The options are Enabled or Disabled. System Bus Event Logging This setting allows you to enable or disable the function of System Bus Error Event logging. The options are Enabled or Disabled. Memory Buffer Event Logging This setting allows you to enable or disable the function of Memory Buffer Event logging. The options are Enabled or Disabled. PCI/PCI Error Logging This setting allows you to enable or disable the function of PCI Error logging. The options are Enabled or Disabled. PCI/PCI Express Error Logging This setting allows you to enable or disable the function of PCI Express Error logging. The options are Enabled or Disabled. 7-11 SUPERSERVER 6014L-T User's Manual MPS Configuration This section allows the user to configure the multiprocessors table. MPS Revision This feature allows the user to select the MPS revision. Please follow the instructions given on the screen to select the MPS revision number. The options are 1.1 and 1.4. PCI Express Configuration This section allows the user to configure the PCI Express slots. Active State Power Management Select Enabled to activate the function of power management for signal transactions between the PCI Express L0 and L1 Links. The options are Enabled and Disabled. I/O Expander Mode This feature allows the user to set the IO Expand Mode for Hot Plug support. The options are PCA9555, Two PCA9554, One PCA9554 (Low), One PCA9554 (High), Two PCA9554A, One PCA9554A (Low), and Two PCA9554. PCI Express PortA (Slot4)/PCI Express PortB (Slot6)/PCI Express PortC0 (NIC1)/PCI Express PortC1 (NIC2) This feature allows the user to configure the PCI Express slot specified. If set to Auto, the slots with IO cards installed will be visible. If Enabled, the IO slots will always be displayed. If set to Disabled, the IO slots will not displayed. The options are Auto, Enabled, and Disabled. PCI Express Compliance Mode Select Enabled to enable MCH to activate the PCI Express Compliance Mode. The options are Disabled and Enabled. Spread Spectrum Select Enabled to enable the function of Spread Spectrum and allows the BIOS to monitor the level of electromagnetic interference caused by the components installed in the system and to attempt to reduce the electromagnetic interference when needed. The options are Disabled and Enabled. Remote Access Configuration You can use this screen to select options for the Remote Access Configuration. Use the up and down arrow keys to select an item. Use the <+> and <-> keys to change the value of the selected option. 7-12 Chapter 7: BIOS Remote Access This feature allows the user to disable the function of Remote Access. If Disabled is not selected, then you can select a Remote Access type. The options are Enabled and Disabled. Remote Access This feature allows the user to enable the Remote Access function. The Options are Enabled and Disabled. If the item "Remote Access" is set to Enabled, you can select a Remote Access type and configure the following settings: Serial Port Number This feature allows the user to select the serial port for Console Redirection. The options are COM1 and COM2. Serial Port Mode This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, N, 1, 57600 8, N, 1, 38400 8, N, 1, 19200 8, N, 1 and 9600 8, N, 1. Flow Control This feature allows the user to set the flow control for Console Redirection. The options are None, Hardware and Software. Redirection After BIOS POST This feature allows the user to select Disabled to turn off Console Redirection after POST. Select Always to keep Console Redirection active all the time. (This setting may not be supported by some operating systems.) Select Boot Loader to keep Console Redirection active during POST and Boot Loader. Terminal Type This feature allows the user to select the target terminal type for Console Redirection.The options are ANSI, VT100 and VT-UTF8. VT-UTF8 Comb Key Support This feature allows the user to select Enabled to enable the VT-UTF8 Combination Key support for the ANSI/VT100 Terminals. The options are Enabled and Disabled. Sredir Memory Display Delay This feature allows the user to decide how many seconds the BIOS shall wait before memory information is displayed. The Default setting is No Delay. 7-13 SUPERSERVER 6014L-T User's Manual USB Configuration USB Function This feature allows you to enable the USB Ports. The options are Disabled and Enabled. Legacy USB Support Select Enabled to enable USB Legacy support. Disable legacy support if there are no USB devices installed in the system. The options are Disabled, Enabled, and Auto. USB 2.0 Controller This setting allows you to enable or disable the USB 2.0 Controller. The options are Disabled and Enabled. USB 2.0 Controller Mode This setting allows you to configure the USB 2.0 Controller Mode. The options are Hi-Speed (480 Mbps) and Full Speed-(12Mbps). USB Mass Storage Device Configurations USB Mass Storage Reset Delay This setting allows you to decide how long the system should wait in an attempt to detect the presence of a USB Mass Storage Device before it issues a start command the system to proceed with the next operation during POST. The options are 10 Seconds, 20 Seconds, 30 Seconds and 40 Seconds. Emulation Type If set to Auto, USB devices that are smaller than 530MB will be emulated as floppy and the remaining will be emulated as an HDD. The Forced FDD option will allow you to configure an HDD formatted drive to boot as an FDD (eg. Zip Drive). The options are Auto, Floppy, Forced FDD, Hard Disk, and CD ROM. System Health Monitor This feature allows the AMI BIOS to automatically display the status of the following items: CPU Overheat Temperature This feature allows the user to set the CPU Overheat temperature threshold. The options range from 65oC to 90oC. Use the <+> and <-> keys to set the desired setting. The default setting is 78oC. 7-14 Chapter 7: BIOS AMI BIOS will automatically monitor and display the following information: CPU1 Temperature, CPU2 Temperature, System Temperature, CPU1 VCORE/ CPU2 VCORE (*for 2U systems), 3.3V Vcc(V), +5 Vin, 12V Vcc(V), -12V Vcc (V), DRAM VTT, 1.2V Vcc, DIMM Voltage, 1.5V Voltage, 5V Standby, 3.3V Standby. System Fan Monitor Fan Speed Control Modes: This feature allows the user to decide how the system controls the speed of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase, and vise versa. If the option is set to “3-pin fan,” the fan speed will be controlled by voltage. If the option is set to “4-pin,” the fan speed will be controlled by Pulse Width Modulation (PWM). Select “3-pin” if your chassis came with 3-pin fan headers. Select “4-pin” if your chassis came with 4-pin fan headers. Select “Workstation” if your system is used as a Workstation. Select “Server” if your system is used as a Server. Select “Disable” to disable the fan speed control function to allow the onboard fans to run at full speed (12V) at all the time. The options are 1. Disable, 2. 3-pin (Server), 3. 3-pin (Workstation), 4. 4-pin (Server) and 5. 4-pin (Workstation). Fan1 Speed to Fan6 Speeds 7-4 Boot Settings 7-15 SUPERSERVER 6014L-T User's Manual BIOS Settings Configuration Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for system bootup. The options are Enabled and Disabled. Quiet Boot This option allows the boot up screen options to be modified between POST messages or the OEM logo. Select Disabled to allow the computer system to display the POST messages. Select Enabled to allow the computer system to display the OEM logo. Add-On ROM Display Mode This option allows the BIOS to display add-on ROM (read-only memory) messages. Select Force BIOS to display a third party BIOS during system boot. Select "Keep Current" to display the current BIOS information during system boot. Boot up Num-Lock This option allows the Number Lock setting to be modified during boot up. The default setting is On. The options are On and Off. PS/2 Mouse Support This option allows the PS/2 mouse support to be modified. The options are Auto, Enabled and Disabled. Wait for ‘F1’ If Error Select Enable to activate the function of Wait for F1 if Error. The options are Enabled and Disabled. Hit ‘DEL’ Message Display Select Enabled to display the Setup Message when the user hits the DEL key. The options are Enabled and Disabled. Interrupt 19 Capture Select Enabled to allow ROMs to trap Interrupt 19. The options are Enabled and Disabled. Quiet Boot Progress Bar Select Enabled to display a graphic bar that shows the progress of POST if the feature of Quiet Boot is enabled. The options are Enabled and Disabled. 7-16 Chapter 7: BIOS Boot Device Priority This feature allows the user to specify the Boot Device priority sequence. The settings are 1st Floppy Drive, CD ROM, ATAPI CDROM and Disabled. The default settings are: · 1st boot device – 1st Floppy Drive · 2nd boot device – SM-Sony CD-ROM CDU · 3rd boot device – 00, AIC-0791A: 1MA · 4th boot device – IBA GE Slot 0300V · 5th boot device – IBA GE Slot 0400V Hard Disk Drives This feature allows the user to specify the boot sequence from available Hard Drives. 1st Drive/2nd Drive/3rd Drive · 1ST boot device – #328 ID01 LUN0 LSI Removable Drives This feature allows the user to specify the boot sequence from available Removable Drives. 1st Drive This option allow the user to specify the boot sequence for 1st Removable Drive. The options are 1st Floppy Drive and Disabled. CD/DVD Drives This feature allows the user to specify the boot sequence from available CD/DVDDrives. 1st Drive This option allows the user to specify the boot sequence for the 1st CD/DVD Drive. The options are SM-Sony CD-ROM CDU, AMI Virtual CDROM and Disabled. 2nd Drive This option allows the user to specify the boot sequence for the 2nd CD/DVD Drive. The options are SM-MATSHITA CR-176, AMI Virtual CDROM and Disabled. PCI-X Slot5 Option ROM/PCI-X Slot6 Option ROM Select Enabled to display the Option ROMs stored in the add-on cards installed on PCI-X Slot5/PCI-X Slot6. The options are Enabled and Disabled. 7-17 SUPERSERVER 6014L-T User's Manual 7-5 Security Settings The AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set first. Change Supervisor Password Select this option and press <Enter> to access the sub-menu, and then type in the password. Change User Password Select this option and press <Enter> to access the sub-menu, and then type in the password. Clear User Password Select this option and press <Enter> to access the sub menu. You can use the sub menu to clear the user password. Boot Sector Virus Protection This option is near the bottom of the Security Setup screen. Select "Disabled" to deactivate the Boot Sector Virus Protection. Select "Enabled" to enable boot sector protection. When Enabled, AMIBOIS displays a warning when any program (or virus) issues a Disk Format command or attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled. 7-18 Chapter 7: BIOS 7-6 Exit Options Select the Exit tab from the AMIBIOS Setup Utility screen to enter the Exit BIOS Setup screen. Saving Changes and Exit When you have completed the system configuration changes, select this option to leave the BIOS Setup and reboot the computer, so the new system configuration parameters can take effect. Select Save Changes and Exit from the Exit menu and press <Enter>. Discarding Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>. Discarding Changes Select this option and press <Enter> to discard all the changes and return to the AMIBIOS Utility Program. Load Optimal Defaults To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, Select "OK" to allow the AMI BIOS to automatically load Optimal Defaults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications. 7-19 SUPERSERVER 6014L-T User's Manual Load Fail-Safe Defaults To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Safe settings are designed for maximum system stability, but not for maximum performance. 7-20 Appendix A: AMIBIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen. Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs. These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list, on the following page, correspond to the number of beeps for the corresponding error. All errors listed, with the exception of Beep Code 8, are fatal errors. POST codes may be read on the debug LEDs located beside the LAN port on the motherboard backplane. See the description of the Debug LEDs (LED1 and LED2) in Section 2-6. A-1 AMIBIOS Error Beep Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset. (Ready to power up.) 5 short, 1 long Memory error No memory detected in system 8 beeps Display memory read/write error Video adapter missing or with faulty memory A-1 SUPERSERVER 6014L-T User's Manual A-2 DS7/DS8 LED Post Codes LED Indicators DS7 DS8 On On Off Off On Off On Off Description/Message PWR On SPD Read OK Memory Size-OK Starting Bus Initialization A-2 Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint Codes When AMIBIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, diagnostic equipment can be attached to the computer to read I/O port 0080h. B-1 Uncompressed Initialization Codes The uncompressed initialization checkpoint codes are listed in order of execution: Checkpoint Code Description D0h The NMI is disabled. Power on delay is starting. Next, the initialization code checksum will be verified. D1h Initializing the DMA controller, performing the keyboard controller BAT test, starting memory refresh and entering 4 GB flat mode next. D3h Starting memory sizing next. D4h Returning to real mode. Executing any OEM patches and setting the Stack next. D5h Passing control to the uncompressed code in shadow RAM at E000:0000h. The initialization code is copied to segment 0 and control will be transferred to segment 0. B-1 SUPERSERVER 6014L-T User's Manual B-2 Bootblock Recovery Codes The bootblock recovery checkpoint codes are listed in order of execution: Checkpoint Code Description E0h The onboard floppy controller if available is initialized. Next, beginning the base 512 KB memory test. E1h Initializing the interrupt vector table next. E2h Initializing the DMA and Interrupt controllers next. E6h Enabling the floppy drive controller and Timer IRQs. Enabling internal cache memory. Edh Initializing the floppy drive. Eeh Looking for a floppy diskette in drive A:. Reading the first sector of the diskette. Efh A read error occurred while reading the floppy drive in drive A:. F0h Next, searching for the AMIBOOT.ROM file in the root directory. F1h The AMIBOOT.ROM file is not in the root directory. F2h Next, reading and analyzing the floppy diskette FAT to find the clusters occupied by the AMIBOOT.ROM file. F3h Next, reading the AMIBOOT.ROM file, cluster by cluster. F4h The AMIBOOT.ROM file is not the correct size. F5h Next, disabling internal cache memory. FBh Next, detecting the type of flash ROM. FCh Next, erasing the flash ROM. FDh Next, programming the flash ROM. FFh Flash ROM programming was successful. Next, restarting the system BIOS. B-2 Appendix B: BIOS POST Checkpoint Codes B-3 Uncompressed Initialization Codes The following runtime checkpoint codes are listed in order of execution. These codes are uncompressed in F0000h shadow RAM. Checkpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on condition. 05h The BIOS stack has been built. Next, disabling cache memory. 06h Uncompressing the POST code next. 07h Next, initializing the CPU and the CPU data area. 08h The CMOS checksum calculation is done next. 0Ah The CMOS checksum calculation is done. Initializing the CMOS status register for date and time next. 0Bh The CMOS status register is initialized. Next, performing any required initialization before the keyboard BAT command is issued. 0Ch The keyboard controller input buffer is free. Next, issuing the BAT command to the keyboard controller. 0Eh The keyboard controller BAT command result has been verified. Next, performing any necessary initialization after the keyboard controller BAT command test. 0Fh The initialization after the keyboard controller BAT command test is done. The keyboard command byte is written next. 10h The keyboard controller command byte is written. Next, issuing the Pin 23 and 24 blocking and unblocking command. 11h Next, checking if <End or <Ins> keys were pressed during power on. Initializing CMOS RAM if the Initialize CMOS RAM in every boot AMIBIOS POST option was set in AMIBCP or the <End> key was pressed. 12h Next, disabling DMA controllers 1 and 2 and interrupt controllers 1 and 2. 13h The video display has been disabled. Port B has been initialized. Next, initializing the chipset. 14h The 8254 timer test will begin next. 19h Next, programming the flash ROM. 1Ah The memory refresh line is toggling. Checking the 15 second on/off time next. 2Bh Passing control to the video ROM to perform any required configuration before the video ROM test. 2Ch All necessary processing before passing control to the video ROM is done. Looking for the video ROM next and passing control to it. 2Dh The video ROM has returned control to BIOS POST. Performing any required processing after the video ROM had control 23h Reading the 8042 input port and disabling the MEGAKEY Green PC feature next. Making the BIOS code segment writable and performing any necessary configuration before initializing the interrupt vectors. 24h The configuration required before interrupt vector initialization has completed. Interrupt vector initialization is about to begin. B-3 SUPERSERVER 6014L-T User's Manual Checkpoint Code Description 25h Interrupt vector initialization is done. Clearing the password if the POST DIAG switch is on. 27h Any initialization before setting video mode will be done next. 28h Initialization before setting the video mode is complete. Configuring the monochrome mode and color mode settings next. 2Ah Bus initialization system, static, output devices will be done next, if present. See the last page for additional information. 2Eh Completed post-video ROM test processing. If the EGA/VGA controller is not found, performing the display memory read/write test next. 2Fh The EGA/VGA controller was not found. The display memory read/write test is about to begin. 30h The display memory read/write test passed. Look for retrace checking next. 31h The display memory read/write test or retrace checking failed. Performing the alternate display memory read/write test next. 32h The alternate display memory read/write test passed. Looking for alternate display retrace checking next. 34h Video display checking is over. Setting the display mode next. 37h The display mode is set. Displaying the power on message next. 38h Initializing the bus input, IPL, general devices next, if present. See the last page of this chapter for additional information. 39h Displaying bus initialization error messages. See the last page of this chapter for additional information. 3Ah The new cursor position has been read and saved. Displaying the Hit <DEL> message next. 3Bh The Hit <DEL> message is displayed. The protected mode memory test is about to start. 40h Preparing the descriptor tables next. 42h The descriptor tables are prepared. Entering protected mode for the memory test next. 43h Entered protected mode. Enabling interrupts for diagnostics mode next. 44h Interrupts enabled if the diagnostics switch is on. Initializing data to check memory wraparound at 0:0 next. 45h Data initialized. Checking for memory wraparound at 0:0 and finding the total system memory size next. 46h The memory wraparound test is done. Memory size calculation has been done. Writing patterns to test memory next. 47h The memory pattern has been written to extended memory. Writing patterns to the base 640 KB memory next. 48h Patterns written in base memory. Determining the amount of memory below 1 MB next. 49h The amount of memory below 1 MB has been found and verified. 4Bh The amount of memory above 1 MB has been found and verified. Checking for a soft reset and clearing the memory below 1 MB for the soft reset next. If this is a power on situation, going to checkpoint 4Eh next. B-4 Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description 4Ch The memory below 1 MB has been cleared via a soft reset. Clearing the memory above 1 MB next. 4Dh The memory above 1 MB has been cleared via a soft reset. Saving the memory size next. Going to checkpoint 52h next. 4Eh The memory test started, but not as the result of a soft reset. Displaying the first 64 KB memory size next. 4Fh The memory size display has started. The display is updated during the memory test. Performing the sequential and random memory test next. 50h The memory below 1 MB has been tested and initialized. Adjusting the displayed memory size for relocation and shadowing next. 51h The memory size display was adjusted for relocation and shadowing. 52h The memory above 1 MB has been tested and initialized. Saving the memory size information next. 53h The memory size information and the CPU registers are saved. Entering real mode next. 54h Shutdown was successful. The CPU is in real mode. Disabling the Gate A20 line, parity, and the NMI next. 57h The A20 address line, parity, and the NMI are disabled. Adjusting the memory size depending on relocation and shadowing next. 58h The memory size was adjusted for relocation and shadowing. Clearing the Hit <DEL> message next. 59h The Hit <DEL> message is cleared. The <WAIT...> message is displayed. Starting the DMA and interrupt controller test next. 60h The DMA page register test passed. Performing the DMA Controller 1 base register test next. 62h The DMA controller 1 base register test passed. Performing the DMA controller 2 base register test next. 65h The DMA controller 2 base register test passed. Programming DMA controllers 1 and 2 next. 66h Completed programming DMA controllers 1 and 2. Initializing the 8259 interrupt controller next. 67h Completed 8259 interrupt controller initialization. 7Fh Extended NMI source enabling is in progress. 80h The keyboard test has started. Clearing the output buffer and checking for stuck keys. Issuing the keyboard reset command next. 81h A keyboard reset error or stuck key was found. Issuing the keyboard controller interface test command next. 82h The keyboard controller interface test completed. Writing the command byte and initializing the circular buffer next. 83h The command byte was written and global data initialization has completed. Checking for a locked key next. 84h Locked key checking is over. Checking for a memory size mismatch with CMOS RAM data next. 85h The memory size check is done. Displaying a soft error and checking for a password or bypassing WINBIOS Setup next. B-5 SUPERSERVER 6014L-T User's Manual Checkpoint Code Description 86h The password was checked. Performing any required programming before WINBIOS Setup next. 87h The programming before WINBIOS Setup has completed. Uncompressing the WINBIOS Setup code and executing the AMIBIOS Setup or WINBIOS Setup utility next. 88h Returned from WINBIOS Setup and cleared the screen. Performing any necessary programming after WINBIOS Setup next. 89h The programming after WINBIOS Setup has completed. Displaying the power on screen message next. 8Ch Programming the WINBIOS Setup options next. 8Dh The WINBIOS Setup options are programmed. Resetting the hard disk controller next. 8Fh The hard disk controller has been reset. Configuring the floppy drive controller next. 91h The floppy drive controller has been configured. Configuring the hard disk drive controller next. 95h Initializing the bus option ROMs from C800 next. See the last page of this chapter for additional information. 96h Initializing before passing control to the adaptor ROM at C800. 97h Initialization before the C800 adaptor ROM gains control has completed. The adaptor ROM check is next. 98h The adaptor ROM had control and has now returned control to BIOS POST. Performing any required processing after the option ROM returned control. 99h Any initialization required after the option ROM test has completed. Configuring the timer data area and printer base address next. 9Ah Set the timer and printer base addresses. Setting the RS-232 base address next. 9Bh Returned after setting the RS-232 base address. Performing any required initialization before the Coprocessor test next. 9Ch Required initialization before the Coprocessor test is over. Initializing the Coprocessor next. 9Dh Coprocessor initialized. Performing any required initialization after the Coprocessor test next. 9Eh Initialization after the Coprocessor test is complete. Checking the extended keyboard, keyboard ID, and Num Lock key next. Issuing the keyboard ID command next. A2h Displaying any soft errors next. A3h The soft error display has completed. Setting the keyboard typematic rate next. A4h The keyboard typematic rate is set. Programming the memory wait states next. A5h Memory wait state programming is over. Clearing the screen and enabling parity and the NMI next. A7h NMI and parity enabled. Performing any initialization required before passing control to the adaptor ROM at E000 next. A8h Initialization before passing control to the adaptor ROM at E000h completed. Passing control to the adaptor ROM at E000h next. B-6 Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description A9h Returned from adaptor ROM at E000h control. Performing any initialization required after the E000 option ROM had control next. Aah Initialization after E000 option ROM control has completed. Displaying the system configuration next. Abh Uncompressing the DMI data and executing DMI POST initialization next. B0h The system configuration is displayed. B1h Copying any code to specific areas. 00h Code copying to specific areas is done. Passing control to INT 19h boot loader next. B-7 SUPERSERVER 6014L-T User's Manual Notes B-8 Appendix C: Software Installation Appendix C Software Installation After all the hardware has been installed, you must first configure the Adaptec Embedded Serial ATA RAID driver before you install the Windows operating system. The necessary drivers are all included on the Supermicro bootable CDs that came packaged with your serverboard. The following section provides information on Adaptec's SATA RAID driver based on the Intel ICH5R/6300ESB controller. C-1 Introduction Serial ATA (SATA) Serial ATA (SATA) is a physical storage interface that uses a single cable with a minimum of four wires to create a point-to-point connection between devices. SATA is a serial link that supports transfer rates from 150MBps. Because the SATA cables are thinner than the traditional cables used for Parallel ATA (PATA), SATA systems have better airflow and can be installed in smaller chassis than PATA. In addition, PATA cables can only extend to 40 cm long, while SATA cables can extend up to one meter. Overall, Serial ATA provides better functionality than Parallel ATA. Intel 6300ESB I/O Controller Hub Located in the South Bridge of Intel's E7520 chipset, the 6300ESB I/O controller hub provides the I/O subsystem with access to the rest of the system. It supports a dual-channel Ultra ATA/100 Bus Master IDE controller (PATA) and two Serial ATA (SATA) Host controllers, which can support up to two Serial ATA ports and two RAID drives. The 6300ESB I/O controller hub supports the following Parallel ATA and Serial ATA device configurations: C-1 SUPERSERVER 6014L-T User's Manual Configuring SATA RAID Note: applies only to Operating Systems that support RAID functions (Windows, Red Hat & SuSe, Linux, etc.) 1. Select "Advanced Setting" from the AMI BIOS menu. 2. Select the IDE Configuration menu. 3. Change the IDE Configuration to "P-ATA Only." 4. Under the item-"Configure S-ATA as RAID", select "Yes". 5. Tap the <Esc> key and scroll down to "Exit". Select "Save and Exit" from the "Exit" menu. Press the <Enter> key to save the changes and exit the BIOS. 6. Once you've exited the BIOS Utility, the system will re-boot. 7. During the system startup, press the <Ctrl> and the <A> keys simultaneously to run the Adaptec RAID Configuration Utility when prompted by the following message: Press <Ctrl><A> for the Adaptec RAID Configuration Utility. Adaptec SATA HostRAID Controller Driver Adaptec's Embedded SATA RAID with HostRAID controller adds RAID functionality to the SATA I/O controller and enhances the performance of PCI-Express based products. RAID striping (RAID 0) allows data to be written across across multiple drives, greatly improving hard disk I/O performance. RAID mirroring (RAID 1) allows data to be simultaneously written to two drives, improving data security even if a single hard disk fails. By incorporating Adaptec's Embedded SATA into the serverboard design, the X6DLP-EG2 offers the user the benefits of SATA RAID without the high costs associated with hardware RAID applications. Note: For instructions on installing Adaptec's RAID driver, please refer to the Adaptec RAID Controller User's Guide ("Emb_SA_RAID_UG.pdf") in the CD that came with the serverboard. You can also download a copy of Adaptec's User's Guide from our web site at www.supermicro.com. Adaptec RAID Configuration Utility (ARC) The Adaptec RAID Configuration utility, an embedded BIOS utility, includes the following: Array Configuration Utility: Use this utility to create, configure and manage arrays. Disk Utilities: Use this option to format or verify disks. C-2 Appendix C: Software Installation To run the Adaptec RAID Configuration utility, do to the following: 1. Enable the RAID function in the system BIOS (refer to Chapter 7 for System BIOS Configurations). 2. Press the <Ctrl> and <A> keys simultaneously when prompted to do so during system boot. (Refer to the previous page for detailed instructions.) Using the Array Configuration Utility (ACU) When you press <Ctrl> and <A> keys simultaneously at the prompt during system bootup, the main menu will appear as seen below. Note: To select an option, use the arrow keys to highlight the item and then press the <Enter> key to select it. To return to the previous menu, press the <Esc> key. C-3 SUPERSERVER 6014L-T User's Manual Managing Arrays Select this option to view array properties and configure array settings. Viewing Array Properties To view the properties of an existing array: 1. At the BIOS prompt, press Ctrl+A. 2. From the ARC menu, select Array Configuration Utility (ACU). 3. From the ACU menu, select Manage Arrays (as shown above.) 4. From the List of Arrays dialog box, select the array you want to view and press Enter. The Array Properties dialog box appears, showing detailed information on the array. The physical disks associated with the array are displayed here. 5. Press Esc to return to the previous menu. C-4 Appendix C: Software Installation Deleting Arrays Warning: Back up the data on an array before you delete it to prevent data loss Deleted arrays cannot be restored. To delete an existing array: 1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2. From the ARC main menu, select Array Configuration Utility (ACU). 3. From the ACU menu, select Manage Arrays. 4. Select the array you wish to delete and press Delete. 5. In the Array Properties dialog box, select Delete and press Enter. The following prompt is displayed: Warning!! Deleting the array will render array unusable. Do you want to delete the array?(Yes/No): RAID 1 only—the following prompt is also displayed: Deleting the partition will result in data loss! Do you also want to delete the partition? (Yes/No): 6. Press Yes to delete the array or partition or No to return to the previous menu. 7. Press Esc to return to the previous menu. Creating Arrays Before you create arrays, make sure that the disks for the array are connected and installed in your system. Note that disks with no usable space and disks that are un-initialized are shown in gray and cannot be used. See Initializing Disk Drives. To create an array 1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2. From the ARC menu, select Array Configuration Utility Main Menu. 3. From the ACU menu, select Create Array. 4. Select the disks for the new array and press Insert (as shown in the screenshot below). Note: To de-select any disk, highlight the disk and press Delete. 5. Press Enter when both disks for the new array are selected. The Array Properties menu displays (as the third following screenshot shows). C-5 SUPERSERVER 6014L-T User's Manual C-6 Appendix C: Software Installation Assigning Array Properties Once you've create a new array, you are ready to assign properties to it. Caution: Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. To assign properties to the new array: 1. In the Array Properties menu, select an array type and press Enter. Only the available array types will be displayed on the screen. (RAID 0 or RAID 1 requires two drives.) 2. Under the item "Arrays Label", type in a label and press Enter. (The label cannot contain more than 15 characters.) 3. For RAID 0, select the desired stripe size. Available stripe sizes are 16, 32, and (the default) 64 KB. It is recommended that you do not change the default setting. 4. The item: "Create RAID via" allows you to select between the different ways of creating RAID 0 and RAID 1 arrays. The following table gives examples of when each is appropriate. C-7 SUPERSERVER 6014L-T User's Manual RAID Levels RAID Level Create Via When Appropriate RAID 0 No Init. Creating a RAID 0 on new drives RAID 0 Migrate* Creating a RAID 0 from one new drive and one drive with data you wish to preserve RAID 1 Build 1 Any time you wish to create a RAID 1 but especially if you have data on one drive you wish to preserve RAID 1 Clear Creating a RAID 1 on new drives or when you want to ensure that the array contains no data after creation RAID 1 Quick Fastest way to creata a RAID 1. Appropriate when using new drives RAID 1 Init Fastest way to creata a RAID 1. Appropriate when using new drives *If you select Migrate for RAID 0, or Build for RAID 1, you will be asked to select the source drive. The contents of the source drive will be preserved, however the data on the new drive will be lost. 5. When you are finished, press Done (as the screen shown below). Notes: 1. Before adding a new drive to an array, back up any data contained on the new drive. Otherwise, all data will be lost. 2. If you stop the Build or Clear process on a RAID 1 from ACU, you can restart it by pressing Ctrl+R. 3. A RAID 1 created using the Quick Init option may return some data miscompares if you later run a consistency check. This is normal and is not a cause for concern. C-8 Appendix C: Software Installation 4. The ACU allows you to use drives of different sizes in a RAID. However, during a build operation, only the smaller drive can be selected as the source or first drive. 5. When migrating from a single volume to RAID 0, migrating from a larger drive to a smaller drive is allowed. However, the destination drive must be at least half the capacity of the source drive. 6. Adaptec does not recommend that you migrate or build an array on Windows dynamic disks (volumes), as it will result in data loss. Warning: Do not interrupt the creation of a RAID 0 using the Migrate option. If you do, you will not be able to restart or recover the data from the source drive. Adding a Bootable Array To make an array bootable: 1. From the Main menu, select Manage Arrays. 2. From the List of Arrays, select the array you want to make bootable and press Ctrl+B. 3. Enter Y to create a bootable array when the following message is displayed: "This will make all other existing bootable array non-bootable. Do you want to make this array bootable? (Yes/No):" A bootable array will then be created. An asterisk will appear next to the bootable array (as shown in the picture below:) C-9 SUPERSERVER 6014L-T User's Manual Deleting a Bootable Array To delete a bootable array: 1. From the Main menu, select Manage Arrays. 2. From the List of Arrays, select the bootable array you want to delete, and press Ctrl+B. (A bootable array is an array marked with an asterisk, as shown in the screenshot above.) 3. Enter Y to delete a bootable array when the following message is displayed: "The array is already marked bootable. Do you want to make this array as not bootable? (Yes/No):" The bootable array will then be deleted and the asterisk will disappear. Note: do not use the delete key to delete the bootable array. Initializing Disk Drives If an installed disk does not appear in the disk selection list for creating a new array or if it appears grayed out, you may have to initialize it before you can use it as part of an array. Drives attached to the controller must be initialized before they can be used in an array. Caution: Initializing a disk overwrites the partition table on the disk and makes any data on the disk inaccessible. If the drive is used in an array, you may not be able to use the array again. Do not initialize a disk that is part of a boot array. To determine which disks are associated with a particular array, please refer to Viewing Array Properties. To initialize drives: 1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2. From the ARC menu, select the Array Configuration Utility (ACU). 3. Select Initialize Drives (as shown in the next screenshot). C-10 Appendix C: Software Installation 4. Use the up and down arrow keys to highlight the disk you wish to initialize and press Insert (as shown in the screenshot below). C-11 SUPERSERVER 6014L-T User's Manual 5. Repeat Step 4 so that both drives to be initialized are selected (as shown below). 6. Press Enter. 7. Read the warning message as shown in the screen. 8. Make sure that you have selected the correct disk drives to initialize. If correct, type Y to continue. C-12 Appendix C: Software Installation Rebuilding Arrays Notes: Rebuilding applies to Fault Tolerant arrays (RAID 1) only. If an array Build process (or initialization) is interrupted or critical with one member missing, you must perform a Rebuild to optimized its functionality. For a critical array Rebuild operation, the optimal drive is the source drive. If no spare array exists and a hard disk drive fails, you need to create a spare before you can rebuild an array. To rebuild an array: 1. From the Main Menu, select Manage Arrays (as shown in the screen below). From the list of arrays, select the array you want to rebuild. 2. Press Ctrl+R to rebuild. C-13 SUPERSERVER 6014L-T User's Manual Using the Disk Utilities The Disk Utilities enable you to format or verify the media of your Serial ATA hard disks. To access the disk utilities: 1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2. From the ARC menu, select Disk Utilities. 3. Select the desired disk and press Enter (as shown below.) C-14 Appendix C: Software Installation You can choose from the following options: 1. Format Disk: Simulates a low-level format of the hard drive by writing zeros to the entire disk. Serial ATA drives are low-level formatted at the factory and do not need to be low-level formatted again. Caution: Formatting destroys all data on the drive. Be sure to back up your data before performing this operation. 2. Verify Disk Media—Scans the media of a disk drive for defects. Exiting the Adaptec RAID Configuration Utility 1. Once you have completed RAID array configurations, press Esc to exit. 2. Select and press Yes to exit the Utility. C-15 SUPERSERVER 6014L-T User's Manual C-2 Installing the ICH5R/6300 ESBDriver 1. Insert Supermicro's bootable CD into the CD drive before a system reboot, and the screen "Super Micro Driver Diskette Maker" will appear. 2. Choose "Intel ICH5R/6300 ESB Driver by 3rd Party (Adaptec)" from the list and press <Enter>. 3. From the next screen displayed, choose the OS driver you want to install and press <Enter>. 4. Insert a formatted diskette into drive A: and press <Enter> as prompted. 5. Exit the program after the process is completed. Then, reboot the system. 6 Insert the Microsoft Windows OS Setup CD in the CD drive, and the system will start to boot up from the CD. 7. Press the <F6> key when the message "Press F6 if you need to install a third party SCSI or RAID driver" displays. 8. When the Windows OS Setup screen appears, press "S" to specify additional device(s). 9. Insert the driver diskette "Adaptec Embedded Serial ATA Raid Controller Driver" into drive A: and press the <Enter> key. 10. Choose "Adaptec Embedded Host Serial ATA Raid Controller" from the list indicated in the Windows OS Setup Screen, and press the <Enter> key. 11. Press the <Enter> key to continue the installation process. (If you need to specify any additional devices to be installed, do so at this time.) Once all devices are specified, press the <Enter> key to continue with the installation. 12. From the Windows OS Setup screen, press the <Enter> key. The OS Setup will automatically load all device files and then, continue the Windows OS installation. 13. After the Windows OS installation is completed, the system will automatically reboot. C-16 Appendix C: Software Installation C-3 Installing Other Software Programs and Drivers A. Installing Additional Drivers After you've installed the Windows Operating System, the screen shown below will appear. You are now ready to install additional software and drivers. To install, click the icons to the right of these items. Driver/Tool Installation Display Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the list. You should install everything here except for the Super Doctor utility, which is optional. The bottom icon with a CD on it allows you to view the entire contents of the CD. C-17 SUPERSERVER 6014L-T User's Manual Supero Doctor III The Supero Doctor III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system. Supero Doctor III displays crucial system information such as CPU temperature, system voltages and fan status. See the Figure below for a display of the Supero Doctor III interface. Note: The default User Name and Password for SuperDoctor III is ADMIN / ADMIN. Supero Doctor III Interface Display Screen-I (Health Information) C-18 Appendix C: Software Installation Supero Doctor III Interface Display Screen-II (Remote Control) Note: SD III Software Revision 1.0 can be downloaded from our Website at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend Supero Doctor II. C-19 SUPERSERVER 6014L-T User's Manual Notes C-20 Appendix D: System Specifications Appendix D System Specifications Processors Single or dual Intel® Xeon® 4 LV or ULV processors in 479-pin PGA sockets Note: Please refer to the support section of our web site for a complete listing of supported processors (http://www.supermicro.com/support/). Chipset Intel E7520/6300ESB Memory Capacity Eight (8) 240-pin DIMM slots to support a maximum of 16 GB registered ECC DDR2-400 SDRAM Serial ATA Controller On-chip (6300ESB) controller (RAID 0, 1, JBOD) Serial ATA Backplane SATA backplane (CSE-SATA-810) for two (2) hot-swap SATA drives Main Drive Bays Two (2) drive bays to house two (2) standard SATA drives Peripheral Bays One (1) 3.5" floppy drive One (1) slim CD-ROM drive PCI Expansion Slots One 64-bit 133/100 MHz PCI-X slot (with riser card, included) Serverboard Model: X6DLP-EG2 (ATX Form Factor) Dimensions: 12 x 9.6 in (305 x 244 mm) Chassis Model: SC811LT-260: (1U Rackmount) Dimensions: (WxHxD) 16.7 x 1.7 x 22 in. (424 x 43 x 559 mm) D-1 SUPERSERVER 6014L-T User's Manual Weight Net (Bare Bone): 28 lbs. (12.7 kg.) Net (Gross): 34 lbs. (15.5 kg.) System Cooling Two (2) 4-cm fans System Input Requirements AC Input Voltage: 100-240 VAC Rated Input Current: 115V to 230V (5A max) Rated Input Frequency: 50 to 60 Hz Power Supply Rated Output Power: 260W (Model# EFA250, Part# PWS-0055) Rated Output Voltages: +3.3V (20A), +5V (25A), +12V (13A), -12V (.8A), +5Vsb (2A) BTU Rating 1372 BTUs/hr (for rated output power of 260W) Operating Environment Operating Temperature: 10º to 35º C (50º to 90º F) Non-operating Temperature: -40º to 70º C (-40º to 158º F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5 to 95% (non-condensing) Regulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant UL Listed (USA) CUL Listed (Canada) TUV Certified (Germany) CE Marking (Europe) D-2
advertisement
Key Features
- Supports two Intel Xeon processors
- Supports up to 16GB of registered ECC DDR2-400 SDRAM
- Has two 64-bit, 66 MHz (3.3V) PCI-X slots
- Has two x8 PCI-Express slots
- Has one 32-bit, 33 MHz (5V) PCI slot
Frequently Answers and Questions
What processors are supported by the X6DLP-EG2 serverboard?
The X6DLP-EG2 supports single or dual Intel Xeon LV or ULV processors in 479-pin PGA sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
What kind of memory does the X6DLP-EG2 serverboard support?
The X6DLP-EG2 has four (4) 240-pin DIMM sockets that can support up to 16 GB of registered ECC DDR2-400 SDRAM. The memory bus is a dual-channel configuration and memory modules must be installed in pairs (two at a time). All memory modules used to populate the system should be the same size, type and speed.
How many SATA drives can the server support?
The server supports two Serial ATA hard drives, which are hot-swappable units. The operating system you use must have RAID support to enable the hot-swap capability of the Serial ATA drives.