United States Stove 2941 is a thermostat-controlled wood-burning circulator designed to provide efficient and reliable heat for your home. With its 6-inch chimney connector, it can be easily installed to vent smoke and combustion products safely to the outside. The heater features a durable cast-iron construction, ensuring longevity and heat retention. It also includes a blower kit for enhanced heat distribution, helping to keep your home warm and comfortable.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Wonderwood 2941 Owner's Manual | Manualzz

HOW TO ORDER REPAIR PARTS

This manual will help you to obtain efficient, dependable service from the heater, and enable you to order repair parts correctly.

Keep this manual in a safe place for future reference.

When writing, always give the full model number which is on the nameplate attached to the inside of the cabinet door of the heater.

When ordering repair parts or options, always give the following information as shown in this list:

1. The PART NUMBER

2. The PART DESCRIPTION

3. The MODEL NUMBER: 2941

4. The SERIAL NUMBER:________________

Before installing your heater, fill in the serial number of your heater in the space provided above.

OWNERS MANUAL

Model 2941

WONDERWOOD

THERMOSTAT CONTROLLED WOOD BURNING CIRCULATOR

WONDERW

OOD

*ASSEMBLY

*INSTALLATION

*OPERATION

*REPAIR PARTS

United States Stove Company

227 Industrial Park Rd.

P.O.Box 151

South Pittsburg, TN 37380

(423) 837-2100 www.USSTOVE.com

SAFETY NOTICE:

If this heater is not properly installed, a house fire may result.

For your safety, follow the installation directions.

Contact local building or fire officials about restrictions and inspection requirements in your area.

CAUTION:

Read all instructions carefully before starting the installation or operation of this heater.

Improper installation may void your warranty.

DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER

Tested to UL 1482 & CAN/ULC-S627

U

NI

TED

U

STATES STO

V

E

S

S

COMPANY

C

United States Stove Company

227 Industrial Park Rd.

P.O.Box 151

South Pittsburg, TN 37380

(423) 837-2100 www.USSTOVE.com

85947-J

TOOLS AND MATERIAL NEEDED

TOOLS

Pencil

6 Foot Folding rule or tape

Tin Snips

Drill, hand or electric

Drill bit, 1/8" dia.

(for sheet metal screws)

Gloves

Screwdriver (blade-type)

5/16" Nut Driver or

5/16" Socket w/Ratchet

MATERIALS

Chimney Connection- 6" Dia. Black

Steel (24 Ga. minimum): Straight or

corrugated elbow (as required)*

1/2" Sheet Metal Screws

6" Inside Diameter Underwriters

Laboratories (UL) listed Residential

Type and Building Heating Appliance

Chimney, Type "HT", or 6" existing

Masonry Chimney with flue liner.

Floor Protector Material: 3' x 4'-6" as

specified on page 4.

Furnace Cement (Manufacturer

recommends: Rutland Code 78 or

Equivalent)

* Avoid adjustable elbows, they leak!

CIRCULATOR DIMENSIONS

Fig. 1

32 1/4 19 1/4

4 1/4

12 1/2

CENTER LINE OF 6"

CHIMNEY CONNECTOR

CENTER LINE

OF 6"

CHIMNEY

CONNECTOR

WONDERWOOD

33 1/2

24

4 1/8

TOP OF FLOOR PROTECTOR

RULES FOR SAFE INSTALLATION AND OPERATION

Read these rules and the instructions carefully.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

1. Check local codes. The installation must comply with their rulings. Do not install this heater in a mobile home or trailer.

2. Always connect this heater to a chimney or vent to the outside. Never vent to another room or inside a building.

3. Do not connect a WOOD burning heater to an aluminum Type B gas vent. This is not safe and is prohibited by all codes. This heater requires connection to approved chimneys: Either a factory built 6" UL 103HT or a lined and approved and recently in spected and cleaned masonry chimney with a 6" flue, preferably round. A larger masonry flue may be used, so long as the flue-section diameter is not greater than 50 sq. in.

The chimney portion (whether factory-built

2

F36 BLOWER KIT

An Optional Blower kit is available for the 2941 Wonderwood automatic wood burning circulator heater. If this kit is not available where you have purchased this Wonderwood heater, you can purchase the F36 Blower Kit directly from the factory. To order contact the United States Stove Company at the address and telephone number given on the back page.

19

NOTE:

DURING OPENING AND CLOSING OF THE FEED AND ASH DOORS

OF THIS HEATER, IT MAY SEEM THAT THE FIT OF THE DOOR IS

"TOO TIGHT". AS THE HEATER IS FIRED, THE GASKETING

"SETTLES" OR "SEATS" ITSELF IN THE DOOR. THE TIGHT FIT AT

THE FACTORY AND BEFORE THE HEATER'S INITIAL FIRING IS TO

INSURE A GOOD SEAL AFTER THE GASKETING "SETTLES".

NOTE:

FOR YOUR SAFETY, WE RECOMMEND INSTALLING SMOKE

DETECTORS IN YOUR HOME IF NOT ALREADY INSTALLED.

SAFETY NOTICE

In the unlikely event that your 2941 "overfires" (a condition evidenced by elbows, stovepipes, and connectors glowing red in appearance or otherwise discoloring), then your installation is subject to excessive draft created by either a chimney too tall or too great in diameter in conjunction with its height, or some other factor of an indeterminate cause. In this event, you should install a barometric draft regulator.

Such installation will preclude any overfiring and/or any hazardous consequences of potential overfiring.

Barometric draft regulators are generally available where you purchased your stove or may be ordered directly from United States Stove Company at a nominal charge.

2001 Consumer Price:

$24.00 - Includes Shipping and Handling

BAROMETRIC DRAFT REGULATOR

Model DR6

18 or masonry) must be tall enough to provide sufficient draft and safe exit of smoke and combustion products. Please refer to Page

5.

4. Be sure that your Chimney is safely con structed and in good repair. Have the chim ney inspected by the Fire Department or a qualified inspector (such as a Chimney sweep). Your insurance company may be able to recommend a qualified inspector.

5. Inspect chimney connector and chimney twice monthly during the heating season for any deposit of creosote or soot which must be removed.

6. Provide air for combustion from outside the house into the room where the heater is located. If the intake is not in the same room, air must have free access to the room.

7. CAST IRON PARTS MUST BE "SEA

SONED" TO AVOID CRACKING. BUILD

ONLY SMALL FIRES ON FIRST USE.

8. To prevent injury, do not allow anyone to use this heater who is unfamiliar with the correct operation of the heater. Do not allow children to use or in any way operate this heater.

9. For further information on using your heater safely, obtain a copy of the National Fire

Protection Association (NFPA) publication

"Using Coal and Wood Stoves Safely" NFPA

No. HS-10-1978. The address of the NFPA is Battery March Park, Quincy, MA. 02269.

10.Keep the ash pit section free of excess ashes. Do not allow ashes to stack higher than the sides of the ash pan.*

11.DISPOSAL OF ASHES- Ashes should be placed in a metal container with a tight fitting lid. Keep the closed container on a noncombustible floor or on the ground, well away from all combustible materials. Keep the ashes in the closed container until all cinders have thoroughly cooled. The ashes may be buried in the ground or used as fertilizer.

12.CAUTION: The special paints used on your heater may give off some smoke while they are curing during first few fires. Build small fires at first. The metal used in construction of the heater has a light coating of oil. This could give off smoke and/or odors when heater is used for the first couple of times.

This should disappear after a short period.

Once this burn-off has occurred, it should not reoccur.

13.CARING FOR PAINTED PARTS- This heater has a painted outside jacket, which is durable but will not stand rough handling or abuse. When installing your heater, use care in handling. Clean with soap and warm water when heater is not hot. DO NOT use any harsh chemicals (acids or caustics) or scouring powder, as these wear and dull the finish.

14.KEEP THE FEED DOOR, ASH DOOR AND

CABINET DOOR CLOSED AT ALL TIMES

EXCEPT WHILE TENDING THE HEATER.

DO NOT OVERFIRE THE HEATER. THIS

WILL HAPPEN IF THE FEED DOOR, OR

PARTICULARLY THE ASH DOOR, IS LEFT

OPEN DURING OPERATION. UNDER EX

TREME CONDITIONS THIS CAN PRO

DUCE DANGEROUS RESULTS. AT A

MINIMUM, IT WILL ALLOW THE PAINT TO

DISCOLOR.

CAUTION: DO NOT TOUCH THE

HEATER UNTIL IT HAS COOLED.

ALWAYS WEAR GLOVES WHEN

REFUELING THIS UNIT OR WORKING

WITH METAL CABINET PARTS.

*

Never allow ashes to contact the grate(s).

MINIMUM CLEARANCES TO COMBUSTIBLE WALLS AND CEILINGS

Minimum clearances to unprotected combustible walls and ceilings as noted by figures 2 through

4 must be maintained. Drapes, curtains, furniture and other combustible materials should be kept much further away from the heater to avoid fire. If you choose to, you may install the heater and chimney connector closer to combustible surfaces than indicated by Figures 2 through 4 IF a clearance reduction system is also installed to protect combustible ceilings and walls near the heater and chimney connector. However, there are limits to how close the heater and chimney connector can be installed to combustible surfaces protected by a clearance reduction system.

A correctly installed clearance reduction system protects the combustible surfaces well beyond the sides and above the top of the heater and beyond the sides and top of the chimney connector pipe.

Two common types of clearance reduction systems use sheet metal with a minimum thickness of 28 gauge (galvanized steel, aluminum, copper) or a 3-1/2 inch (4 inch nominal) thick masonry wall. Either of these materials must be spaced out 1 inch from the combustible surfaces. With sheet metal, non-combustible spacers are used to maintain the 1 inch air space. With a masonry wall, metal wall ties and furring strips, if needed are used to anchor the brick to the wall. To avoid excessive heat transmission, the spacers or wall ties should not be placed directly behind the

3

heater or chimney connector. The 1 inch air space provides free air circulation. It is essential that there be openings at the top and bottom of these clearance reducers so cool air can enter at the bottom and hot air exit at the top. It is the "chimney effect" whereby when the air in the space is heated, it rises exiting from the top and being replaced by cooler air at the bottom, that makes these shields effective.

Masonry, or other non-combustible products, attached directly to a combustible surface without an air space offer very little protection and cannot be considered a clearance reducer unless specified materials have been tested and listed for direct attachment to a combustible surface.

The same applies to thin veneer brick and stone coverings. These materials provide adequate protection only when mounted on sheet metal with a 1 inch spacing to the wall.

A variety or prefabricated clearance reduction systems which have been tested and listed are available through heater dealers. Always look for a safety listing label on the product when selecting a clearance reduction system and make sure it is designed for solid fuel appliances. The manufactures of these systems provide specific installation instructions that must be followed exactly for a safe installation.

LOCATING THE HEATER

AS A LOCATION IS SELECTED,

KEEP THE FOLLOWING IN MIND:

1. The chimney connection should be as airtight as possible. The heater must have its own chimney flue. Do not connect this unit to a chimney flue serving another appliance. If there is no chimney near where you wish to place the heater, you can use a UL 103HT Residential

Type and Building Heating Appliance Chimney (Fig. 5, 6, 6A & 6B).

2. Place the heater on solid masonry or solid concrete. When the heater is used on a combustible floor protector of one layer of 3/8" millboard having a thermal conductivity of

K=0.84 BTU in./ft. 2 hr. Deg. F with 28-gauge sheet metal or a UL Listed floor protector. Have the floor protector extend 16" beyond the door side of the heater and under the connector pipe in the back.

3. Check Figures 2, 3, and 4. Be sure you have the clearances shown from the heater and the connector pipe to combustible surfaces. If you have a solid brick or stone wall behind your heater, you can place the heater as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall.

26"

25"

Fig. 2

WONDERWOOD

Fig. 3

16"

12"

35"

54"

12"

NON-COMBUSTIBLE

CONSTRUCTION IN

ACCORDANCE WITH

NFPA 211

Fig. 4

17"

SIDEWALL

32 1/4"

16"

FLOOR PROTECTOR

(TOP VIEW)

19 1/4"

36"

NOTE: DASHED LINES SHOW

STRAIGHT UP AND THROUGH

THE WALL INSTALLATION

4 3/4"

4

REPAIR PARTS LIST - MODEL 2941 (SEE PAGE 18)

AUTOMATIC WOOD BURNING CIRCULATOR

26

27

28

29

22

23

24

25

30

31

18

19

20

21

14

15

16

17

Key No.

Description

8

9

10

11

12

13

6

7

4

5

3

*

1

2

Heat Jacket Assembly

Base Weldment

Smoke Curtain

Smoke Curtain Bracket

Flue Collar

Flue Collar Gasket

Draft Damper Frame

Draft Control Damper

Draft Damper Hinge Pin

Clip Spring

Fire Grate

Liner

Firebrick

Top Brick Retainer

Feed Door Assembly

Ash Door Assembly

Feed Door

Ash Door

Door Latch

Door Handle

Feed Door Rope Gasket

Ash Door Rope Gasket

1/4-20 Kep Nut

5/16 ID, 3/4 OD Washer

Latch Spacer

Door Hinge Pin (Short)

Door Hinge Pin (Long)

Heat Shield

Drop Wooden Handle

Ash Pan

Solid Damper

Top Liner

Heat Shield

Secondary Heat Shield

1

1

1

1

1

1

1

1

2

1

2

2

1

1

3.75FT

2.5FT

2

2

Qty.

2

3

1

1

10

2

1

1

1

1

1

2

1

1

Part No.

21467

83872

23441

23475

89523

67444

D6

23474

22110

22030

40199

40289

22108

40091

88033

88033

83250

83045

17200

83818

40076

40100

89066

40132

68621

68620

68619

67859

22090

22171

40246

88032

40075

23476

* NOT SHOWN

17

16

CHIMNEY CONNECTION

Two basic types of chimneys are approved for use with solid fuel: Factorybuilt and masonry. Factory-built chimney must comply with UL103HT standard.

Do not expect your stove or furnace to create draft. Draft is not a function of the appliance. Draft is purely a function of the chimney. Modern stoves and furnaces are much more air-tight and efficient than those of the past and, therefore require greater draft. A minimum of .05, measured in water column (gauges to measure chimney draft are readily available at stove shops and are economical to purchase or rent) is required for proper drafting to prevent back-puffing, smoke spillage, and to maximize performance.

Chimneys perform two functions - one

of which is apparent: The chimney provides a means for exhausting smoke and flue gases resulting from combustion of the fuel. Secondarily, though, the chimney provides "Draft" which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible. As of April 1,

1987, all heaters and furnaces manufactured by United States Stove

Company should be installed using a factory built chimney that meets the

"Type HT" requirement of UL 103 (when a factory - built chimney is used).

IMPORTANT

*Size the chimney to the flue outlet on the stove. (6" outlet = 6" I.D. chimney)

*Avoid using elbows except as necessary (they reduce draft).

*Make sure all horizontal runs of connector pipe go up hill (1/4" elevation for each horizontal foot).

10 FT.

2 FT MIN.

CHIMNEY CAP MANDATORY

3 FT.

MIN.

11 FT. MIN.

REFER TO CHIMNEY

MANUFACTURERS PARTS

AND INSTRUCTIONS

BAROMETRIC

DRAFT CONTROL

(OPTIONAL)

PIPE

DAMPER

10 FT.

2 FT MIN.

CHIMNEY CAP MANDATORY

3 FT.

MIN.

11 FT. MIN.

REFER TO CHIMNEY

MANUFACTURERS PARTS

AND INSTRUCTIONS

DAMPER

PIPE

BAROMETRIC

DRAFT CONTROL

(OPTIONAL)

FIG. 5

FLOOR PROTECTOR

FLOOR PROTECTOR

FIG. 6

Cathedral Ceiling - Chimney

Cap Mandatory

5

FIG. 6A - Thru-The-Wall Installation

NON-COMBUSTIBLE

WALL

THIMBLE

COLLAR

PIPE

DAMPER

BAROMETRIC

DRAFT CONTROL

(OPTIONAL)

FLOOR PROTECTOR

CLASS A UL 103HT

CHIMNEY KIT INCLUDING

WALL THIMBLE.

FIG. 6B - Typical Masonry Chimney Installation

APPROVED COWL

2 FT MIN.

10 FT.

MINIMUM

3 FT.

MIN.

6" MIN.

APPROVED

THIMBLE

60" MIN.

DAMPER

BAROMETRIC DRAFT

CONTROL

FLOOR PROTECTOR

6

6"

MIN.

REPAIR PARTS

AUTOMATIC WOOD BURNING CIRCULATOR HEATER

MODEL NUMBER 2941

(SEE PAGE 16)

REPAIR PARTS LIST

19

20

21

15

16

17

18

11

12

13

14

7

8

9

10

KEY NO.

PART NO.

DESCRIPTION

1

2

89062

83005

Cabinet Door Knob

Screw (10-24 x 1/2) FL

5

6

3

4

83033

83093

83244

67968

Screw (8-32 x 1/4) PH,TR,HD,Z

Spring Latch

Kep Nut (10-24)

Cabinet Door Frame

86191 Thermostat Linkage

85381W Control Panel Plate

89142

67725

67967

21593

83833

67966

Thermostat Knob

Cabinet Front Assembly

Cabinet Left Side

Hinge Support

Hinge Clip

Cabinet Top

67743

21063

67514

89065

67969

23477

83406

Thermostat Assembly

Back Brace

Cabinet Back

Door Hinge

Cabinet Door

Top Thermostat Shield

10-16 x 3/4 TORX, WAF, HD,DP,Z

1

1

1

1

1

1

1

1

QTY.

1

1

1

1

1

1

1

1

2

1

4

1

2

15

14

WONDERWOOD

VENTING INTO A FIREPLACE

(Not recommended)

Many people may wish to convert an existing fireplace to heater use. Usually, safe connection of stovepipe to a masonry chimney requires more effort than connection to a prefabricated chimney.

The fireplace must be closed and sealed at the damper in the flue. Good sealants are high temperature caulking, ceramic wool, and furnace cement. Always remember to inspect the masonry chimney and fireplace. If necessary, clean the flue and smoke shelf before beginning your installation. Install the heater into the chimney so that the system can be dismantled for cleaning and inspection.

Many prefabricated fireplaces fall into the "zero-clearance fireplace" category.

This is a factory metal fireplace with multi-layered construction. It is designed to provide enough insulation and/or air cooling so that the base, back and sides can be safely placed in close contact with combustible floors and walls. Although many prefabricated fireplaces have been tested by nationally recognized organizations for use as fireplaces, they have not been tested to accept heaters. In fact, their use as such may void the manufacturer's warranty.

Before deciding to convert your fireplace or existing chimney, keep in mind that older fireplaces and their chimneys are unsafe. They must be structurally sound, and the flue liner must be in good condition. Do not use a chimney if it is

unlined (should have a tile clay liner to protect brickwork), have it relined

professionally. Clearances to combustibles are explained in the previous section on masonry chimneys. If you have any questions regarding the condition of the chimney, consult a qualified engineer, competent mason, certified Chimney Sweep, or knowledgeable inspector.

Steel-lined fireplaces, on the other hand, can be used with heaters. These units use a 1/4-inch fire box liner and an air chamber in connection with 8 inches of masonry to meet code. They contain all the essential parts of a fireplace, firebox, damper, throat, smoke shelf, and smoke chamber. Many of them look exactly like a masonry fireplace and must be checked closely for above requirements before installing a coal heater into them.

Another method frequently used by some people is to vent the heater directly into the fireplace. This does not meet code since the heater is being vented into another appliance - the fireplace. This method should not be attempted because combustion products will deposit and build up in the firebox or fireplace. Be certain not to install a hazard in you house. You will

void your warranty with this installation.

CAUTION:

NOT ALL FIREPLACES

ARE SUITABLE FOR

INSTALLATION OF A WOOD

HEATER.

7

FIREPLACE INSTALLATION

Connection of the stovepipe directly into the existing masonry chimney over the fireplace opening is the only approved method. This installation performs better, yielding easy to clean and inspect for creosote. Before beginning this type of installation plan carefully; a high degree of skill is required to insure safety.

An entry port for the stovepipe must be cut through the chimney with minimum damage to the fire clay liner. Some involved measurements may be required to locate the flue liner exactly. Before cutting, take time to mark the size and position of the entry port. Position the entry port so that at least 8 inches of the flue liner remains below the port.

Keep in mind that wood mantels and combustible trim around the fireplace must have adequate clearances from the heater and stovepipe or must be protected in an approved manner. Also, be sure to leave at least 24" clearance between the top of the stovepipe and the combustible ceiling or other combustibles. Placing the center of the entry port 2 feet below the ceiling will insure proper clearance for 6 inch, 8 inch, and

10 inch stovepipes. Next, install a fire clay (at least 5/8 in. thick) or metal thimble, being sure that the thimble is flush with the inner flue lining. Secure the thimble in place with refractory mortar. The thimble should be surrounded on all sides with 8 inches of brickwork

(solid masonry units) or 24 inches of stone.

Install the stovepipe as far as possible into the thimble, but not past the inside of the flue lining. There should be a small air space (approximately 1/2 in.) between the stovepipe and thimble, allowing for expansion of the stovepipe.

Seal this airspace with high-temperature caulking or ceramic wool. Finally, be sure to wire the damper closed and apply the same sealant you used at the stovepipe and thimble junction.

Do not vent up through the fireplace opening, regardless of whether the fireplace opening is closed.

MASONRY CHIMNEY have several positive attributes: If properly built, they are quite durable, and most homeowners consider them more attractive perhaps than a non-enclosed factory built chimney. And, if the chimney is located within the confines of the house (that is, not attached to an exterior wall), its mass alone will store heat longer and continue to release the heat long after the fire has died. Masonry chimneys have many disadvantages though.

Masonry chimneys constructed on an exterior wall are exposed to cold outdoor temperatures, promoting greater heater loss, higher accumulations of creosote, and reduced draft which leads to poorer heater or furnace performance.

8

SERVICE HINTS

Do not expect a heater to draw. It is the 4. If the chimney is too cool, water will chimney that creates the draft. Smoke spillage into the house or excessive build-up of water or creosote in the chimney are warnings that the chimney condense in the chimney and run back into the stove. Creosote formation will be rapid and may block the chimney.

Operate the heater at a high enough fire is not functioning properly. Possible causes are: to keep the chimney warm preventing this condensation. (Poorly insulated chimney)

1. The connection pipe may be pushed into the chimney too far, stopping the draft (Fig. 8).

2. Two heaters connected into the same chimney flue.

3. Same flue being used to ventilate the cellar or basement. If there is a cleanout opening at the base of the chimney, it must be closed tightly and sealed.

5. The chimney top may be lower than another part of the house or a nearby tree. The wind blowing over a house or a tree falls on top of the chimney like water over a dam, beating down the smoke. The top of the chimney should be at least 3 feet higher than any point of the roof within 10 feet (Fig. 6).

6. Other chimney/flue inadequacies covered else where in this manual.

NOTE:

A draft reading of .05 to .06 w.c. is suggested for proper burning of this unit.

CHIMNEY MAINTENANCE

CREOSOTE-FORMATION AND NEED FOR REMOVAL

When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire.

If creosote has accumulated, it should be removed.

Failure to remove creosote or soot may cause a house fire. Creosote may be removed by using a chimney brush or other commonly available materials. Or, better yet, by a certified chimney sweep.

The chimney connector and chimney should be inspected at least twice monthly during the heating season to determine if a creosote build-up has occurred.

Chimney fires burn very hot. If the chimney connector should glow red, immediately call the fire department, then reduce the fire by closing the inlet air control and closing the damper in the pipe.

CAUTION

A chimney fire may cause ignition of wall studs or rafters which you thought were safe distance from the chimney. If you have a chimney fire, have your chimney inspected by a qualified person before using again.

13

CABINET DOOR KNOB ASSEMBLY

The door knob is mounted inside of the cabinet door to facilitate shipping and must be reversed for proper usage.

To get cabinet door open, place hand under cabinet frame (right hand side of cabinet door) and push door out.

INSTALL THE CABINET DOOR KNOB USING THE STEPS

BELOW:

1. Remove the machine screw and door knob (Fig. 10).

2. Place door knob on outside of cabinet door. Then place machine screw through hole and into door knob and tighten (Fig.

11).

MACHINE

SCREW

CABINET DOOR

KNOB

Fig. 10

12

Fig. 11

When considering a masonry chimney, round tiles are preferable to square or rectangular, as round tiles have much better airflow characteristics and are far easier to clean. Unfortunately, most

North American chimneys use square or rectangular tile liners that are really designed for open fireplaces, not stoves or furnaces. Of most importance, second only to overall chimney height, is the diameter of the flue liner itself. In most instances, it should be sized to the appliance; i.e., 6" flue outlet on the appliance requires a 6" flue. The inner diameter should never be less than the flue outlet diameter and should never be greater than 50% of the appliance flue outlet. For example, do not expect a wood burning stove or furnace to function properly if installed into a chimney with a flue liner greater than 50% the appliance outlet -

- such as a 6" flue outlet requires a 6" diameter for optimum drafting, but can function well with an 8", but becomes borderline beyond 8" diameter.

solid fuel appliance must not be joined to a chimney flue which is connected to another appliance burning other fuels.

If your chimney has a typically oversized flue liner of 8x12 inches or greater, or if it is unlined, it will be necessary for you to reline the chimney, using many of the modern approved and economical methods such as stainless steel, castable refractory, or properly sized fireclay linings.

If you have any question regarding venting your appliance, feel free to contact the factory at the address and phone number on this Owner's Manual. You may also contact NFPA (National Fire Protection

Association) and request NFPA Standard

211 (1984 Edition). Their address is

Battery March Park, Quincy,

Massachusetts 02269. Another helpful publication is NFPA Standard 908, available at the same address. Specify

1984 Edition on either of the above publications.

Masonry chimneys built of concrete blocks without flue liners of at least 5/8" fireclay do not meet modern building codes. A

5/8" FIRECLAY

FLUE LINER

TYPE "A"

FIREPLACE

CONVERSION

Fig. 7

STOVEPIPE CONNECTOR

SEALED AT THIMBLE

HORIZONTAL 6" STOVEPIPE

(24 GAUGE) WITH 1/4"

RISE PER FOOT

6" STOVEPIPE ELBOW

CLEARANCE REDUCER

(FOR MANTEL)

6" STOVEPIPE - HAVING

THREE SHEET METAL SCREWS

PER JOINT OF STOVEPIPE

9

U.L. LISTED

FLOOR PROTECTOR

DAMPER THROAT

CLOSED AND SEALED

RULES FOR CONNECTOR PIPE INSTALLATION

1. The crimped end of the stovepipe fits

5. Seal each connector pipe joint with

inside the heater flue collar. Install adfurnace cement. Also seal the pipe at ditional pipe and elbow with the the chimney.

CRIMPED END TOWARD THE

HEATER. This will allow any

6. Use 3 Sheet Metal screws at each condensation in the flue to run back into the heater. Smoke will not escape when joint to make the piping rigid.

installed in this manner.

2. Slope any horizontal pipe upward toward the chimney at least 1/4 inch for each foot of horizontal run.

3. You must have at least 18 inches of clearance between any horizontal piping and the ceiling.

7. It is recommended that no more than two 90 degree bends be used in the stovepipe installation as more than two may decrease the amount of draw and if possible, use only corrugated (nonadjustable) elbows. They are much more airtight.

4. The pipe cannot extend into the chimney flue. (Fig. 8)

8. The chimney connector must not pass through an attic or roof space, closet, or any concealed space, or floor, ceiling, wall or combustive construction.

RIGHT WRONG

Fig. 8

WRONG

HOW TO LIFT THE TOP

CAUTION - DO NOT OPEN OR CLOSE TOP WHEN HEATER IS HOT!

To open, grasp TOP at front and lift all the way, then gently lower the TOP until the TOP SUPPORT ROD latches to hold the TOP (Fig. A).

To close, lift TOP until the TOP SUPPORT ROD is unlatched. Pull the ROD forward and lower the TOP (Fig. B).

SUPPORT ROD

TOP

SUPPORT

SEAT

GRASP TOP

HERE TO

OPEN

WONDERWO

OD

WONDERWO

OD

A

Fig. 9

10

B

OPERATING INSTRUC-

TIONS

FUEL

Hardwood, 18" to 23" should be split and air dried (seasoned) for 6 months to obtain maximum burning efficiency.

CAUTION: BUILD A FIRE ON THE

INTEGRAL GRATE THAT IS PRO-

VIDED WITH THE HEATER.

CAUTION: STORING OF WOOD

WITHIN MINIMUM CLEARANCES OF

HEATER MAY CAUSE HOUSE FIRE.

Wood should be stored in a dry, well ventilated area. A Wooden box or crate is ideal for storage.

NOTE: USE SOLID WOOD MATERIAL

ONLY. DO NOT USE COAL.

DO NOT USE MANUFACTURED OR

CHARCOAL LOGS!

CAUTION: DO NOT OVERFIRE THE

HEATER, AS STATED EARLIER, THIS

CAN PRODUCE A DANGEROUS

CONDITION AND EVEN CAUSE A

HOUSE FIRE. IF ANY PORTION OF

THE HEATER OR ANY CHIMNEY

CONNECTOR GLOWS RED OR DIS-

COLORS, THE HEATER IS BEING

OVERFIRED.

LIGHTING

1. Set the thermostat on "High" for maximum draft.

2. Open the feed door and place paper and kindling on the grate for starting the fire.

3. Light fire and close feed door.

4. Add fuel after fire is burning briskly.

Use care not to smother the kindling fire.

5. Set thermostat higher or lower for desired temperature.

CAUTION: DO NOT OPERATE THIS

HEATER WITH FEED OR ASH DOOR

OPEN. THIS HEATER IS DESIGNED

FOR THERMOSTATIC OPERATION.

OPERATION WITH EITHER DOOR

OPEN WILL OVERHEAT AND DAM-

AGE THE HEATER.

CAUTION: NEVER STORE FLAM-

MABLE LIQUIDS, ESPECIALLY

GASOLINE, IN THE VICINITY OF THE

HEATER.

ADDING FUEL

When possible, add small amounts of fuel each hour or so instead of adding large quantities of fresh fuel every 4 to

5 hours. This will give more complete combustion and less build-up of tars or soot in the chimney.

1. Set Thermostat to HIGH before opening feed door.

2. Empty ash pan regularly. Do not allow ashes to build up to grate as grate will warp and burnout will occur, and you might spill the ashes when removing the pan. Dispose of hot ashes properly (see Note 11 on Page 3).

CAUTION:

HOT WHILE IN OPERATION.

KEEP CHILDREN, CLOTHING

AND FURNITURE AWAY.

CONTACT MAY CAUSE

SKIN BURNS.

11

CAUTION: NEVER USE GASOLINE,

GASOLINE-TYPE LANTERN FUEL,

KEROSENE, CHARCOAL LIGHTER

FLUID, OR SIMILAR LIQUIDS TO

START OR "FRESHEN UP" A FIRE IN

THE HEATER.

DO NOT BURN GARBAGE OR FLAM-

MABLE FLUIDS.

DO NOT CONNECT TO ANY AIR

DISTRIBUTION DUCT OR SYSTEM.

NOTE: BEFORE FIRING

HEATER

1. Remove plastic knob from inside of cabinet door and install on outside of door.

(See Page 15)

2. Slide firebricks toward the rear so no gaps remain between them.

advertisement

Key Features

  • Thermostat controlled
  • Wood burning
  • Circulating heat
  • Safe operation
  • Easy to install
  • Efficient heating

Frequently Answers and Questions

What are the minimum clearances to combustible walls and ceilings?
Minimum clearances to unprotected combustible walls and ceilings are as follows: 18 inches to side walls, 36 inches to rear wall, and 48 inches to ceiling. However, a clearance reduction system can be used to reduce these clearances.
What type of chimney is required for this heater?
This heater requires connection to approved chimneys: Either a factory built 6" UL 103HT or a lined and approved and recently inspected and cleaned masonry chimney with a 6" flue, preferably round. A larger masonry flue may be used, so long as the flue-section diameter is not greater than 50 sq. in.
What is the recommended method for disposing of ashes?
Ashes should be placed in a metal container with a tight fitting lid. Keep the closed container on a noncombustible floor or on the ground, well away from all combustible materials. Keep the ashes in the closed container until all cinders have thoroughly cooled. The ashes may be buried in the ground or used as fertilizer.
How should the heater be cleaned?
Clean the heater with soap and warm water when the heater is not hot. Do not use harsh chemicals (acids or caustics) or scouring powder, as these wear and dull the finish.
What is the recommended frequency for inspecting the chimney connector and chimney?
Inspect the chimney connector and chimney twice monthly during the heating season for any deposit of creosote or soot which must be removed.