Stacked Dryers

-Hz Models

Instructions

Part No. 3402328

Before you start...

Check locatlon where dryers will be used. Proper installation is your responsibility. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Make sure you have everything necessary for correct installation.

Each of the dryers Is equipped with a timer, selector switches and indicator lights. The timers are set to provide

45 minutes (4 pins) of drying time when activated by the coin slide. Timer cams for 30-minute (6 pins) and &-minute

(3 pins) drying timers are supplied with the unit in the parts bag. See Pages

7 and 8 for timer cam changing instructions.

The coin-slide mechanisms, control panel lock and key, coin box and coin box locks and keys are not included and are available from usual industry sources.

Protectlon from weather:

Proper operation requires temperatures above 7°C (45°F).

The wiring diagram is located inside the control panel and access panels.

Check utlllttes:

Proper suoolv connections muit be available.

+t

Important: Observe all governing codes and ordinances.

l/&lncrkPT plugged tapplng Is required.

See “Gas supply

:’ j:jjjjjjji:..:.:: Page 3.

_...-

Dryers may be exhausted from

Fire Hazard

For your safety, the lnformatlon In thls manual must be followed to mlnlmlre the rlsk ot tlre or explosion or to prevent property damage, personal

InJury or loss

0r iir8.

- Do Not store or use gasoline or other flammable vapors and llqulds In the vlclnlty ot thls or any other appliance.

- WHAT TO DO IF YOU SMELL GAS:

Do Not try to light any appliance.

Do Not touch any electrlcal switch; Do Not use any phone

In your bulldlng.

Clear the room, bulldlng or area

0r all occupants. lmmedlately call your gas suppller from a nelghbor’s phone. Follow the gas suppller’s

Instructions.

- If you cannot reach your gas suppller, call the fire department.

- Never Install dryer up agalnst draperies or curtains or on carpet.

- Keep any and all Items from falling or collecting behlnd the dryer.

Installation and service must be performed by a qualltled Installer, service agency or the gas suppller.

Post thls warnlng In a promlnent locatlon.

J

It is recommended that the operator post, in a prominent location, instructions for the customer’s use in the event that the customer smells gas. This information should be obtained from your local gas supplier.

Page 2

support the total welght of 143 kg

(315 pounds) per unit.

Level floor:

Maximum floor slope under dryers - 2.5 cm (1 inch).

Electrlcal Shock Hazard

It Is the customer’s responslblllty to contact a licensed electrlclan, and to have dryers

Installed according to all natlonal and local codes and ordinances.

Failure to tallow these lnstructlons could result In death or serious InJury.

Fire Hazard

If you Install dryers In a garage, carport, or areas near vehicles where fumes from gasoline or other vapors may be present, the vapors may be heavier than alr and remain near the rloor.

;roun&d electrlcal outlet is reauired. See “Electrical requlrements,” Page 4.

Locatlon must be large enough to fully open dryer doors. See Page 7 for recessed area requirements and

Droduct dimensions.

Place dryers a mlnlmum of 45.7 cm (18 Inches) above tloor.

Check wlth your bulldlng

Inspector regarding requirements for thls Installation.

Failure to follow these lnstructlons could result In a fire or exploslon.

InJury Hazard

More than one person Is required to Iltt, tilt, or move the dryers because ot their welght and size.

Failure to follow thls lnstructlon may result In Injury.

Tools needed for installation:

adjustable wrench utility knife

Phillips screwdriver

Bat-blade screwdriver dew level glasses pliers duct tape gloves

Parts supplied for installation:

2 slide protectors

2 slide extensions

2 bolt and washer assemblies

8 screws

2, SO-minute cams

2,60-minute cams

4.314” wood screws

Parts owner must

supply:

1 control panel lock and key

2 coin vaults and keys (E.S.D. vault must have projecting lock.)

2 coin-slide mechanisms (vertical 8)

Parts may be ordered from

Greenwald Industries, Inc. or

Equipment Systems and Devices, Inc. l

Greenwald Industries, Inc.

1340 Metropolitan Avenue

Brooklyn, NY 11237 telephone (7 18) 82 l-9000 or toll free (800) 221-0982 fax(718)417-7412 l

Equipment Systems and

Devices, Inc.

270 New Jersey Dr.

Fort Washington, PA 19034 telephone (215) 628-0860 or toll free (800) 523- 1510 fax (215) 643-4623 l

Monarch

P.O. Box 427

105-l 15 East Fourth St.

Covington, KY 41011

Gas supply reauhements

Fire Hazard

Dryers must be connected to a regulated gas supply.

Failure to do so could result In hlgh- pressure gas release, resulting In a fire or exploslon.

Have L.P. gas checked by a quallfled person bdore lnstalllng the dryer. The L.P. gas supply must not exceed 13 Inches water column pressure.

New, flexible tublng should be used.

Reuslng old, flexible tublng mlght result In possible gas leaks.

Failure to follow these lnstructlons could result In flre or exploslon.

OBSERVE ALL GOVERNING CODES

AND ORDINANCES.

A n

This installation must conform with American National Standard,

National Fuel Gas Code ANSI Z223.1- latest edition,* and all local codes and ordinances.

B n

The desian of this drver has been certified by the American Gas

Association for use at altitudes up to

3000 m (10.000 feet) above sea level at the B.T.U. rating indicated on the model/serial rating plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

When installed above 3000 m (10,000 feet), a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial rating plate is required for each 300 m (1 ,ooO foot) increase in elevation, For assistance when converting to other gas types and/or installing above 3000 m (10,000 feet) elevation, contact your local service company.

C n

Check that dryers are equipped with the correct burner for the particular type of gas used.

Burner information will be found on the rating plate in door well of the appliance. If thls information does not agree with the type of gas available, see your dealer.

D n

These dryers are shipped for use with NATURAL GAS.

They are certified by the American Gas

Association for manufactured, mixed and L.P.

(propane and butane) gases with appropriate conversion. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas suppller.

Converslon must be done by a quallfled service technlclan. Gas converslon klt part numbers are llsted on the gas valve burner base.

E n

Provide a rlgld gas supply line of l/2-inch IPS pipe to ihe dryer’s location. If the total length of the supply line is more than 6.1 m

(20 feet), larger pipe will be needed.

For L.P. gas usage, 3/8-inch, approved copper tubing may be used. Pipe-ioint comDounds suitable fge with L.P. gas should be used

F

n

If local codes and ordinances permit, it is recommended that new flexible metal tubing, design-certified by the American Gas Association. be used for connecting the dryers to the gas supply line. (The gas feed pipe. which extends through the lower rear of each dryer, is provided with

3/8-inch male plpe thread.)

G w The SUDDIV line shall be equipped with a manual shutoff valve. This valve should be located in the same room as the dryers and should be in a location that allows ease of opening and closing. Do Not block access to shutoff valve.

H. connec main gas supply line, a combination of fittings must be used to obtaln an in-line connection to the dryers.

Copies of the standards listed above may be obtained from:

*American Gas Association

11515 Wilson Boulevard

Arlington, Virginla 22209

Page 3

I n Make sure lower edges, back and sides of the cabinet are free of obstructions to permit adequate clearance of air openings for combustton air. See ‘Recessed area and closet installation instructions” for minimum spacing requirements.

J

W For ease of installation, operating and servicing (if ever needed), adequate space should be provided around the dryers.

K n A l/&inch, NPT pluaaed tapping, accessible for testgauge connection, must be installed immediately upstream of the gas supply connector to the dryers.

The dryers and their individual shutoff valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of l/2 psig

(3.4 kPa).

The dryers must be isolated from the gas supply piping system by closing their individual manual shutoff valves during any pressure testing of the gas supply piping system at test pressures equal to or less than l/2 psig

(3.4 kPa). shutott valve -4 l/0”

(3.2 mm) pipe plu (for check1

7 s l/2” (I 2.7 mm), as supply Ine

$ lock Iron pipe) ttexlble

/ connector

(use A.G.A. desl n-

1 connector)

Electrical reauirements

a

Electrlcal Shock Hazard

Electrlcal ground Is required for dprs.

Do Not ground to a gas pipe.

Do Not change the power supply cord plugs. If plugs will not flt outlets have proper outlets Installed by a quallfled electrlclan.

Do Not have a fuse In the neutral or groundlng clrcult. A tuse In the neutral or groundlng clrcult could result In an electrlcal shock.

Do

Not use an extension cord wlth this appliance.

Check wlth a quallfled electrlclan If you are not sure dryers are properly grounded.

Failure to follow these lnstructlons could result In death or serious

Injury.

If codes permit and a separate groundlng wire Is used, It Is recommended that a qualltled electrlclan determlne that the groundlng path Is adequate.

OBSERVE ALL GOVERNING CODES

AND ORDINANCES.

A 230-volt, 50-Hz, AC-only, 15- or

20-ampere fused electrical supply is required. Time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit for the dryers be provided.

Kgrdmended grounding

For your personal safety, these dryers must be grounded. Each dryer is equipped with a power supply cord having a 3-prong grounding plug. To minimize shock hazard, the cords must be plugged into mating 3-prong grounding-type wall receptacles, grounded in accordance with local codes and ordinances, If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, J-prong wall receptacle installed by a quallfled techniclan.

Schuko .

L n If the dryers are installed in a confined area such as a bathroom or closet, they must be exhausted to the outside and provislon made for enough air for combustion and ventilation. (Check governlng codes and ordinances. Also refer to the sectlon of thls Instruction covering

‘Recessed and closet Installations.“)

Page 4

Exhaust requirements

Fire Hazard

Do Not use non-metal, tlexlble duct.

Do Not use metal duct smaller than

10.2 cm (tour Inches) In diameter.

Do Not use exhaust hoods wlth metal latches.

Check that exhaust system Is not longer than specltled. Exhaust system longer than speclfled will:

- Accumulate Ilnt.

- Shorten the llfe ot the dryer.

- Reduce the performance, resulting In longer drylng times and Increased energy usage.

Failure to r0ii0w specltlcatlons may result In a tire.

Do Not exhaust dryers Into a chimney, turnace cold alr duct, alilc or crawl space, or any other duct used ror ventlng.

Clean the exhaust system every other year.

Do Not Install tlexlble duct In enclosed walls, celllngs or floors.

Accumulated lint could result In a fire or cause moisture damage.

Exhaust dryers outslde to prevent exposure to substances In gas tuels and combustion which may be harmful to your health.

The moisture and llnt Indoors may cause:

- FIRE HAZARD tram llnt collected In dryer.

- Moisture damage to woodwork, furniture, palnt, wallpaper, carpet, etc.

- Housecleanlng problems and possible health problems.

Failure to tallow these lnstructlons could result In a tlre or Inlury. ixhaust materials are not supplled.

It uslng an exlstlng exhaust system, clean llnt from entlre length ot exhaust system. Make sure exhaust hood Is not plugged wlth Ilnt.

The exhaust system should be

Inspected and cleaned yearly.

Replace any vlnyl or metalllzed plastic toll exhaust duct wlth rlgld metal or tlexlble metal duct.

Use duct tape to seal all joints. Do Not use screws to secure duct.

10.2-cm (tour-

Inch) metal exhaust duct is required. Plan installation to use the fewest number of elbows and turns, exhaust air tlow better good i?zJ

Metal tlexlble duct must be fully extended and supported when the dryers are in final position, DO NOT

KINK OR CRUSH THE DUCT. The metal flexible duct must be completely open to allow adequate exhaust air to flow.

Allow as much room as possible when using elbows or making turns. Bend duct gradually to avoid kinking.

Remove excess flexible duct to avoid sagging and kinking that may cause reduced airflow.

The external exhaust ducts can be routed straight out the back of the dryers. Kits are available to convert the external exhaust duct to be routed right, left or through the bottom (See Page 6). Product dimensions and recessed area requirements are given on Page 7.

Slde or bottom exhaust:

The maximum length of the exhaust system through the side or bottom is

4.9 m (16 feet) wlth two external elbows and hood.

Rear exhaust:

The maximum length of the exhaust system depends on the type of duct, the number of elbows and the type of exhaust hood. The maximum length for both rigid and flexible duct is shown in the chart.

Thls chart applies only to lndlvldually exhausted unlts.

I

EXHAUST HOOD TYPE

Service check:

The back pressure in any exhaust system used must not exceed 0.6 inches of water column measured with an incline manometer at the point that the exhaust system connects to the dryers.

If dryers are Installed In a conflned area such as a bedroom, bathroom or closet, they must be exhausted to the outslde and provislon must be made for enough air for combustion and ventilation. (Check governing codes and ordinances. Also refer to the “Recessed area and closet installation instructions,” Page 7.)

An exhaust hood should cap the exhaust duct to prevent exhausted air from returning into the dryers. The outlet hood must be at least 30.5 cm

(12 inches) from the ground or any object that may be in the path of the exhaust.

10.2-cm (four-Inch) outlet hood ls preferred.

However, a 6.4-cm (2-l /2- inch) outlet exhaust hood may be used. (A 64cm (2-l/2-inch) outlet creates greater back pressure than other hoods.)

A maln exhaust duct can be used for exhausting a group of dryers. Main exhaust duct should be sized to remove 18.6 CCM (200 CFM) of air per dryer. Large-capacity lint screens of proper design may be used in the main exhaust duct if checked and cleaned frequently. The room where the dryers are located should have make-up air equal to or greater than the CFM of all the dryers in the room. airflow - maincolleciorducl -

E!$i2

IQ2 all (4-l

9;s

I(12 cm (F

WIMUM LENGTH OF 10.2~cm (4-inch) DIAMEIERRIGID MEIAL DUC

0 13.1 m (43’) 12.5 m (41’) 11.0 m (36’)

1 10.1 m (33’)

9.4 m (31’)

7.9 m (26’)

2 7.0 m (23’)

6.4 m (21’)

4.9 m (16’)

I I I

AXIMUM IfNGiH OF 10.2~cm @-inch) DIAMETER FLWBLE METAL DUC

0

1

2

9.1 m (JO’)

8.8 m (29’)

7.3 m (24’)

7.0

4.9 m (16’)

4.6 m (23’) m (15’)

7.3 m (24’)

5.5 m (18’)

3.0 m (10’)

For exhaust systems not covered by the exhaust length chart, see

WhirtDool Service Manual, “Exhausting

Whirlpool Dryers,” Part No. 603197, available from your Whirlpool parts distributor.

Back-drattdamper kits

(Part No.

3391910) are available from your

Whirlpool dealer and should be installed in each dryer’s exhaust duct to prevent exhausted air from returning into the dryers and to keep the exhaust balance within the main exhaust duct. Unobstructed air openings are required.

Each exhaust duct should enter the main duct at an angle pointing in the direction of the airflow. Ducts entering from the opposite side should be staggered to reduce the exhausted alr from interfering with the other ducts,

The maxlmum angle of each duct entering the main duct should be no more than 30”.

Page 5

Keep air openlngs free ot dry- cleaning fluld fumes. Fumes create acids which, when drawn through the dryer heatlng unlts, can damage dryers and loads being drled.

A clean-out cover should be located on the main exhaust duct for periodlcally cleaning the exhaust system.

An exhaust hood should cap the outside end of the main duct to prevent exhausted air from returning to the dryers. If an exhaust hood cannot be used, the outside end of the main duct should have a sweep elbow directed downward. If the main duct travels vertically through the roof rather than through the wall, install 180” sweep elbow on the end of duct at least 61 cm (2 feet) above the highest part of the building. The opening wall or roof shall have a diameter 1.3 cm (l/2 inch) larger than the exhaust duct diameter. The exhaust duct should be centered in the opening. exhaust hood or

WCIII hortzontal duct

Exhaust duct connection

Determine which direction you need to attach the exhaust ducts to the dryers, Both dryers can be exhausted straight out the back or from the right or left side. The lower dryer can also be exhausted through the bottom.

Next, determine the length of exhaust duct you will need to connect the dryers to exhaust hoods or the main exhaust.

To connect exhaust duct straight out the back -

=z~$$p

WQII

61 cm

(2 ft. mkt.)

180” sweep dbOW hlgheat polnt ot bulldIng

5 s

3

E

B T maln collector duct root dF

Do

Not install screening cap over end of duct.

Attach exhaust duct to each dryer duct. Then connect exhaust ducts to exhaust hoods or main exhaust. Use duct tape to seal all joints.

To connect exhaust duct to the right, left or bottom -

Use one of the following kits to convert the dryers. Follow kit instructions to avoid operating problems.

Exhaust Kit No. 279818 (White)

Exhaust Kit No. 279819 (Almond)

Recessed area and closet installations

Fire Hazard

Dryers MUST be exhausted to

Wslde. i

20 Not exhaust dryers Into a

4 chimney, turnace cold alr duct, attlc t or crawl space, or any other duct used tar ventlng.

Failure to tallow these lnstructlons could result In a flre.

Stacked dryers may be Installed In a recessed area.

The installation spacing is in centimeters and inches and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing and compliance with local codes and ordinances.

If closet door is installed, the mlnimum unobstructed air openings in the top and bottom are required. Door must have two centered openings as illustrated. Both openings must provide a minimum of 465 sq cm

(72 square inches) of unobstructed airflow as shown. Louvered doors with equivalent air openlngs are acceptable.

FOR CLOSET INSTALLATIONS, TO

PREVENT LARGE AMOUNTS OF LINT

AND MOISTURE FROM

ACCUMULATING, TO MAINTAIN

DRYING EFFICIENCY, AND TO PREVENT

TO POSSIBLE

HAZARDS, DRYERS MUST BE EXHAUSTED

OUTDOORS.

It yoy q recessed front view

Addlttonal clearances may be required for wall, door and floor moldtngs It external exhaust elbow

Is used.

(I

Page 6

Ocmj

(0”) closet side view

Product dimensions

side view

F’

I

191 CI

(75-l/ n

‘4”) c

To than e to a

$ timing cam

-B.

0

Additional space may be needed for exhaust elbow. Additional clearances fog wall, door and floor moldings may be required. closet door front view

T

h-

7.6 cm

WI

0

154.8 sq cii

(2P sq. in.2

+

7.6 cm w

T-

Opening is minimum for closet door.

Louvered door with e uivalent air openings Is acceptab

9

8.

Corn anion appliance spacing should be

No other fuel-burning appliance may be installed in the same closet. approx,

2.5 cm

(1”)

-

Electrlcal Shock Hazard

Disconnect both power supply cords betore changing timer cams.

Failure to tallow thls lnstructlon could result In death or serlous Injury. rear view

I3

34.9 cm

(13-314”)

2.5 cm _

J

(1’3, IFi& -4 .-.-. .- et

118.7’cm I, cm

Each dryer is equipped with a 45 minute tlmer cam that provides 45 minutes of drying time when activated by the coin slide.

You can install the 30-minute or 60 minute timing cam (shipped with each dryer) as follows:

1.

Unlock control panel. Lift up and rotate out from cabinet. Control panel will still be attached to cabinet.

2. Reach into control panel area. Use a Phillips screwdriver to loosen @ut not remove) timer mounting bracket screw. Lift up to remove timer assembly and bracket from cabinet.

17.1 cm

(6-314”) cm (4”) timing cam

3. Turn the timing cam by hand until me “W-shaped notch lines up below me ratchet tooth.

Page 7

to clear ratchet tooth.

4. Insert a narrow, flat-blade screwdriver under the timing cam near the clock shaft. Gently lift cam stralght up and off shaft maklng sure that the “V-shaped notch clears the ratchet tooth.

5. Place new cam (hub side down) over clock shaft. Line up flat side of shaft with flat side of cam hole.

Check that drive lug is in place,

6.

Turn cam until “Y-shaped notch lines up with ratchet tooth.

7. Press cam down in place on motor shaft. Make sure that Y-shaped notch clears the ratchet tooth,

8.

Reattach the timer bracket assembly; tighten the screws.

9. Repeat steps for other timer.

10.

Close and lock the control panel.

Now start...

With dryers in laundry area.

1 n

Put on gloves and safety glasses.

Check that each leg is approximately

2.5 cm (1 inch) from base.

2.

Wipe the interior of the drums thoroughly with a damp cloth.

3.

Install coin vaults and locks (not supplied) into meter case openings.

4.

Install control panel lock and key (not supplied).

5.

If you wish to change the 45-minute dryer timing cams to either 30- or 60- minute timing cams, see “To change to a 30 or 60-minute timlng cam,”

Pages 7 and 8. Complete all of the steps given in that section before going to Step 6.

Open control panel and rest it on the bottom edge of the opening. Attach slide extension (with flange pointing down) to one of the coin-slide mechanisms. Insert the coin-slide mechanism through the opening to the left of the control panel.

7.

Secure coin-slide mechanism from inside the control panel using the

3/16” bolt and washer supplied. Install coin box.

8.

Repeat Steps 6 and 7 for the other coin-slide mechanism. Close control panel, l i

9.

Insert top of wire guard into holes on each side of the coin-slide mechanism. Insert screws through hooked ends of guard and tighten.

Repeat for other wire guard.

Page 8

16 n

Check levelness of dryers by placing a carpenter’s level on top of the dryers or collar, first side to side, then front to back. If dryer Is not level. adjust the front legs up or down.

Make the final check with the level.

Remove the red caps from the gas pipes.

11.

Connect gas supply to each dryer.

Use pipe-joint compound resistant to the action of Natural and L.P. gas for gas connections.

12.

Open the shutoff valves in the gas supply lines.

Plug power supply cords into grounded outlets, Turn on electrical power supply.

Betore movlng dryers across floor, slide dryers onto cardboard or hardboard to protect rloor coverlng.

Move unit to its permanent location.

15.

Turn one dryer on to remove air from the gas supply line. Using a full heat cycle (not the air cycle), let the dryer run for at least five minutes. If the burner does not ignite and you can feel no heat inside the dryer, shut off the dryer for five minutes. Check that all supply valve controls are In “ON” position and that the power supply cord is plugged in. Repeat the five- minute test.

17.

To exhaust the dryers, see “Exhaust requirements” and “Exhaust duct connection,” Pages 5 and 6.

Injury Hazard

To prevent tlpplng, tether bracket must be secured to wall studs or concrete wall.

Failure to do so could result In

InJury. tether bracket lo at rear of the top

Fire Hazard

Do Not use an open flame to test tar leaks from gas connectlons.

Checking for leaks wlth a flame may result In a tire or explosion.

13.

Use a brush and liquid detergent to test all gas connections for leaks.

Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again.

NEVER TEST FOR

GAS LEAKS WITH A FLAME.

Close the access panels.

All connectlons must be wrench- tightened.

Attach both ends of tether located at

, ,

2 x4.

Page 9

If dryers do not operate properly...

Check the followlng to be sure that:

1. Electrical supply is connected.

2. Circuit breakers are not tripped or fuses blown.

3. Doors are closed.

4. Timer has been actuated.

5. Controls are set in a running or

“ON” position,

6. Gas shutoff valves are open both on dryer and supply Ilne.

Move dryers to a new location...

Before movlng dryers across tloor, slide dryers onto cardboard or hardboard to protect tloor coverlng. l

Shut off electrical supply to dryers. l l

Disconnect power supply cords and tape securely to dryer.

Shut off the gas supply valves in the gas supply line. l l l

Disconnect gas pipe and fittings from dryer and cap the gas supply line. Tape end of dryer gas pipes.

Tape the drums to the front panel.

Tape doors to cabinet. l

Adjust leveling legs all the way in.

Before installing dryers in a new location, check with your gas supplier or dealer to see that your dryer is equipped with the correct burner for the particular type of gas in your new building. Burner informatlon may be found on the model/serial rating plate in the door well of the dryer.

Page 11

Part No. 3402328

0 1995 Whirlpool Corporation

Prepared by Whirlpool Corporation, Benton Harbor, Michigan 49022

Printed in U.S.A.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What are the gas supply requirements for the Whirlpool 3402328 dryers?
The dryers must be connected to a regulated gas supply. A rigid gas supply line of 1/2-inch IPS pipe or, for L.P. gas usage, 3/8-inch, approved copper tubing, should be used. The supply line should be equipped with a manual shutoff valve.
What are the electrical requirements for the Whirlpool 3402328 dryers?
The dryers require a 230-volt, 50-Hz, AC-only, 15- or 20-ampere fused electrical supply. A time-delay fuse or circuit breaker is recommended, and a separate circuit for the dryers is advised.
Can the Whirlpool 3402328 dryers be installed in a confined area?
Yes, the dryers can be installed in a confined area, such as a bathroom or closet, provided that they are exhausted to the outside and adequate air is provided for combustion and ventilation. Refer to the manual's section on 'Recessed and Closet Installations' for specific guidelines.
What tools are needed for the installation of the Whirlpool 3402328 dryers?
The following tools are required for installation: adjustable wrench, utility knife, Phillips screwdriver, flat-blade screwdriver, glasses, level, pliers, duct tape, gloves, and a drill.