TECHNICAL SPECIFICATIONS
INPUT VOLTAGE .................... 10 to 30 Vdc
INPUT CURRENT ................... 3.75A at 12.8V, 2A at 25.6V
INPUT POWER ........................ 50 Watts
OUTPUT POWER .................... 40 Watts
OUTPUT ENERGY................... 34 Joules
FLASH PATTERNS................... 12
QUICK REFERENCE
4.35"
2.00"
HEIGHT: 1.65"
402
INPUT VOLTAGE: 10 to 30 Vdc
INPUT CURRENT: 3.75A
INPUT POWER: 50 WATTS
OUTPUT POWER: 40 WATTS shutting this unit off before attempting service.
MADE IN U.S.A.
RED: +V
BLACK: - GND
VIOLET: PATTERN SELECT
ALTERNATE
3.
EPS Xtreme
40 Watt, 2 outlet
Strobe Power Supply
INSTALLING THE EPSX402 …
When mounting in a location which is exposed to water, the STROBE
HEAD OUTLET
CONNECTORS must be sealed .
Use RTV Silicone Rubber
Sealant. Do Not put on electrical contacts!
TO HEAD
TO POWER
SUPPLY
4. POWER HARNESS
Connect the RED wire to +12/24V through an ON/OFF switch. A 10 AMP fuse should be installed as close as possible to the voltage source.
Connect the BLACK wire to - Ground.
MOUNTING TABS
DIA: 0.20"
Note: Use the correct size wire for power connections.
The length of the wires determines the size needed.
1 to 15 ft. use 18AWG wire.
15 to 30 ft. use 16AWG wire.
30 to 45 ft. use 14AWG wire.
45 and over, use 12AWG wire.
1.
2.
RED: +
BLACK:
VIOLET:
10 to 30 Volts
- GROUND
FLASH PATTERN
SELECTION
ORANGE
BLACK
YELLOW
3
2
1
RED
BLACK
VIOLET
POWER HARNESS
INSTALLING THE EPSX402
Mounting
The EPSX402 can be mounted to a flat surface. The holes in the mounting tabs will accept up to a #10 screw.
Connect Strobe Heads
The two outlets alternate with each other.
ORANGE
BLACK
WHITE
OR YELLOW
1
2
3
EPSX402
WHIT
E
3
2
1
STROBE HEAD
OUTLETS
RED or GREEN
BLACK
WHITE or CLEAR
STROBE HEAD CABLE
The VIOLET
When the wire selects the FLASH PATTERN.
VIOLET wire is momentarily pattern in the flash pattern list.
The EPSX402 will remember the flash pattern you select even when power is removed, or the EPSX402 is removed from the vehicle.
The VIOLET wire can be run to a momentary pushbutton located inside the vehicle if you wish to change flash patterns frequently.
connected to
+12/24V the EPSX402 will advance to the next flash
# Flash Pattern
FLASH PATTERN LIST
Description
1 Random, Level 5 Randomly selects from all patterns and runs each pattern 5 times.
2 Single Flash
3 Double Flash
4 Triple Flash
5 Quad Flash
6 Quintuple Flash
Single flash alternating, 200 Flashes per minute.
2 Flash Bursts Alternating, 125 double flashes per minute.
3 Flash Bursts Alternating, 140 Triple Flashes per minute.
4 Flash Bursts Alternating, 140 Quad Flashes per minute.
5 Flash Bursts Alternating, 140 Quintuple Flashes per minute.
Single flash alternating, 700 Flashes per minute.
7 Mega Flash
8 Phased Mega Flash Flashrate varies from 360 FPM to 860 FPM
9 Warble
10 Single-Double
11 Single-Quad
12 Cycle Flash
6 Single flashes at 450 FPM, 6 single flashes at 860 FPM.
Single Flash, Double Flash combination.
Single Flash, Quad Flash combination.
Classic EPS Cycle Flash. Cycles through Double-Quad-Mega.
Pattern selection loops back to Pattern 1 when incremented past Pattern 12.
TIP: Connecting VIOLET to +12/24V while turning power switch ON will reset the flash pattern to pattern #1.
BASIC WIRING WITH SIMPLE ON/OFF SWITCH
WARNING!
High Voltage
Please wait 5 minutes after attempting service.
ALTERNATE
402
INPUT VOLTAGE: 10 to 30 Vdc
INPUT CURRENT: 3.75A
INPUT POWER: 50 WATTS
OUTPUT POWER: 40 WATTS
MADE IN U.S.A.
RED: +V
VIOLET: PATTERN SELECT
WIRING DIAGRAM 1
10A FUSE
Battery + or
Fuse Panel.
Battery or nearby chassis ground.
RED,
BLACK,
VIOLET
CONNECTOR
3
2
1
3
1
2 TURN EPSX402 ON AND TOUCH
VIOLET WIRE TO A NEARBY
+12/24V CONNECTION TO SELECT
FLASH PATTERN.
RED
ON/OFF
SWITCH
(10 AMP)
LEAVE VIOLET UNCONNECTED OR
TIE TO BLACK WIRE (GROUND)
WHEN FINISHED SELECTING
FLASH PATTERN.
BLACK
VIOLET
POWER HARNESS
WIRING DIAGRAM 2
ON/OFF AND FLASH PATTERN SELECTION
TROUBLESHOOTING
If the EPSX402 stops working check the following:
1) POWER CONNECTIONS
Check for corroded connections to +12/24V and Ground.
A bad connection will cause the voltage to drop at the
EPSX402. The EPSX402 will shut off if the voltage drops below 10 Volts.
2) OUTPUT SHORT CIRCUIT.
The EPSX402 will shut down if there is a short circuit condition on any one of the strobe heads. If the electrical conductors connecting the power supply to the strobe heads are exposed to water a short circuit will result. The first sign is intermittent operation, followed by complete shutdown of the strobe system.
To find the short circuit, unplug all strobe head cables from the
EPSX402. Test one cable/head at a time until the problem is found. Water shoring shows as a blue/green colored residue where the short circuit has occurred.
WARNING!
High Voltage
Please wait 5 minutes after attempting service.
ALTERNATE
402
INPUT VOLTAGE: 10 to 30 Vdc
INPUT CURRENT: 3.75A
INPUT POWER: 50 WATTS
OUTPUT POWER: 40 WATTS
MADE IN U.S.A.
BLACK: - GND
VIOLET: PATTERN SELECT
3
2
1
2
3
1
10A FUSE
Battery + or
Fuse Panel.
Battery or nearby chassis ground.
6
7
4
5
2
3
#
1
8
9
10
11
12
FLASH PATTERN LIST CUTOUTS
THESE LISTS MAY BE CUT-OUT AND USED
ON CUSTOM SWITCH PANELS, ETC.
Flash Pattern
Random, Level 5
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Description
Randomly selects from all patterns and runs each pattern 5 times.
Single flash alternating, 200 Flashes per minute.
2 Flash Bursts Alternating, 125 double flashes per minute.
3 Flash Bursts Alternating, 140 Triple Flashes per minute.
4 Flash Bursts Alternating, 140 Quad Flashes per minute.
5 Flash Bursts Alternating, 140 Quintuple Flashes per minute.
Single flash alternating, 700 Flashes per minute.
Phased Mega Flash Flashrate varies from 360 FPM to 860 FPM
Warble
Single-Double
Single-Quad
Cycle Flash
6 Single flashes at 450 FPM, 6 single flashes at 860 FPM.
Single Flash, Double Flash combination.
Single Flash, Quad Flash combination.
Classic EPS Cycle Flash. Cycles through Double-Quad-Mega.
RED,
BLACK,
VIOLET
CONNECTOR
ON/OFF
SWITCH
(10 AMP)
RED
BLACK
VIOLET
POWER
HARNESS
PATTERN
SELECT
PATTERN SELECT SWITCH
IS A MOMENTARY, NORMALLY OFF,
LOW CURRENT PUSHBUTTON SWITCH.
(CURRENT THROUGH SWITCH IS LESS THAN 0.005A)
PRESSING PATTERN SELECT WILL INCREMENT
THE FLASH PATTERN.
PRESS AND HOLD PATTERN SELECT WHILE
TURNING THE POWER SWITCH ON TO RESET
FLASH PATTERN TO #1.
ACCESSORIES
The following accessories are available to make the installation of the EPSX402 power supply even easier:
SWITCH-EPSX
ON/OFF with PATTERN SELECT pushbutton switch panel with 15 foot pre-wired harness. Provides the same function as WIRING DIAGRAM 2.
1 Random
2 Single Flash
3 Double Flash
4 Triple Flash
5 Quad Flash
6 Quintuple Flash
7 Mega Flash
8 Phased Mega
9 Warble
10 Single-Double
11 Single-Quad
12 Cycle Flash
1 Random
2 Single Flash
3 Double Flash
4 Triple Flash
5 Quad Flash
6 Quintuple Flash
7 Mega Flash
8 Phased Mega
9 Warble
10 Single-Double
11 Single-Quad
12 Cycle Flash
1 Random
2 Single Flash
3 Double Flash
4 Triple Flash
5 Quad Flash
6 Quintuple Flash
7 Mega Flash
8 Phased Mega
9 Warble
10 Single-Double
11 Single-Quad
12 Cycle Flash
ON
OFF
FLASH
PATTERN
7
8
5
6
3
4
1
2
9
10
11
12
Random
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Phased Mega
Warble
Single-Double
Single-Quad
Cycle Flash