INSTALLATION SHEET
833 West Diamond Street, Boise, ID 83705 TEL: 800-635-5900 www.eccogroup.com
EPS Xtreme
40 Watt, 4 outlet
Strobe Power Supply
TECHNICAL SPECIFICATIONS
INSTALLING THE EPSX404...
INPUT VOLTAGE...........................10 to 30 Vdc
INPUT CURRENT..........................3.75A at 12.8V, 2A at 25.6V
INPUT POWER..............................50 Watts
OUTPUT POWER..........................40 Watts
OUTPUT ENERGY.........................34 Joules
FLASH PATTERNS........................12
QUICK REFERENCE
4.35"
HEIGHT: 1.65"
INPUT VOLTAGE: 10 to 30 Vdc
WARNING!
High Voltage
INPUT POWER: 50 WATTS
RED: +V
BLACK: - GND
VIOLET: PATTERN SELECT
5.55"
WHITE FLASH
TOGETHER
5.15"
4.70"
OUTPUT POWER: 40 WATTS
ALTERNATE
MOUNTING TABS
DIA: 0.20"
ORANGE
BLACK
YELLOW
1
2
3
ORAN
GE
BLACK
YELL
OW
TE
HI
W
1
2
3
WH
ITE
3
1
2
3
RED: + 10 to 30 Volts
BLACK: - GROUND
VIOLET: FLASH PATTERN
SELECTION
2
1
2
3
1
STROBE HEAD
OUTLETS
3 2 1
Outlets with the same
color wires fire at the same time.
RED
POWER HARNESS
BLACK
VIOLET
1. Mounting
The EPSX404 can be mounted to a flat surface. The holes in
the mounting tabs will accept up to a #10 screw.
EPSX404
920-9071-00 REV. A
3 2
1
2. Connect Strobe Heads
Outlets with WHITE wires fire at the same time and alternate
with the outlets that have YELLOW wires.
1
2
3
TO POWER
SUPPLY
Note: Use the corrected size wire for power connections.
The length of the wires determines the size needed.
1 to 15 ft. use 18AWG wire.
15 to 30 ft. use 16AWG wire.
30 to 45 ft. use 14AWG wire.
45 and over, use 12AWG wire.
The VIOLET wire selects the FLASH PATTERN. When the
VIOLET wire is momentarily connected to +12/24V EPSX404
will advance to the next flash pattern in the flash pattern list. The EPSX404 will remember the flash pattern you select from
the vehicle.
The VIOLET wire can be run to a momentary push-button
located inside the vehicle if you wish to change flash patterns
frequently.
FLASH PATTERN LIST
INSTALLING THE EPSX404
ORANGE
BLACK
WHITE
OR YELLOW
TO HEAD
Connect the BLACK wire to - Ground.
INPUT CURRENT: 3.75A
www.eccogroup.com
MADE IN USA
YELLOW FLASH
TOGETHER
Use RTV Silicone Rubber
Sealant. Do Not put on
electrical contacts!
4.POWER HARNESS
Connect the RED wire to +12/24V through an ON/OFF
switch. A 10 AMP fuse should be installed as close as possible to the voltage source.
2.00"
Please wait 5 minutes after
shutting this unit off before
attempting service.
3. When mounting in
a location which is
exposed to water,
the STROBE
HEAD OUTLET
CONNECTORS
must be sealed.
RED or GREEN
BLACK
WHITE or CLEAR
STROBE HEAD CABLE
#
Flash Pattern:
Description:
1
Random, Level 5
Randomly selects from all patterns and runs each pattern 5 times
2
Single Flash
Single Flash Alternating, 200 Flashes per minute
3
Double Flash
2 Flash Bursts Alternating, 125 double flashes per minute
4
Triple Flash
3 Flash Bursts Alternating, 140 Triple Flashes per minute
5
Quad Flash
4 Flash Bursts Alternating, 140 Quad Flashes per minute
6
Quintuple Flash
5 Flash Bursts Alternating, 140 Quintuple Flashes per minute
7
Maga Flash
Single Flash alternating, 700 Flashes per minute
8
Phased Maga Flash
Flash rate Varies from 360 FPM to 860 FPM
9
Warble
6 Single flashes at 450 FPM, 6 Single flashes at 860 FPM
10
Single-Double
Single Flash, Double Flash combination
11
Single-Quad
Single Flash, Quad Flash combination
12
Cycle Flash
Classic EPS Cycle Flash, Cycles Though Double-Quad-Mega
Pattern selection loops back to Pattern 1 when incremented past Pattern 12
TIP: Connecting VIOLET to +12/24V while turning power
switch ON will reset the flash pattern to pattern #1.
PAGE 1
WIRING DIAGRAM 1
TROUBLESHOOTING
BASIC WIRING WITH SIMPLE ON /OFF SWITCH
INPUT CURRENT: 3.75A
INPUT POWER: 50 WATTS
OUTPUT POWER: 40 WATTS
Battery or nearby
chassis ground.
www.eccogroup.com
MADE IN USA
ALTERNATE
YELLOW FLASH
TOGETHER
Battery + or
Fuse Panel.
INPUT VOLTAGE: 10 to 30 Vdc
WARNING!
High Voltage
Please wait 5 minutes after
shutting this unit off before
attempting service.
If the EPSX404 stops working check the following:
WHITE FLASH
TOGETHER
RED: +V
BLACK: - GND
VIOLET: PATTERN SELECT
10A FUSE
1
2
3
1
2
3
1
2
3
3
2
1
1
2
3
ON/OFF
SWITCH
(10 AMP)
3 2 1
RED,
BLACK,
VIOLET
CONNECTOR
RED
BLACK
VIOLET
TURN EPSX402 ON AND TOUCH
VIOLET WIRE TO A NEARBY
+12/24 CONNECTION TO SELECT
FLASH PATTERN.
LEAVE VIOLET UNCONNECTED OR
TIE TO BLACK WIRE (GROUND)
WHEN FINISHED SELECTING
FLASH PATTERN.
POWER HARNESS
1) POWER CONNECTIONS
Check for corroded connections to +12/24V and Ground.
A bad connection will cause the voltage to drop at the
EPSX404. The EPSX404 will shut off if the voltage drops
below 10 Volts.
2) OUTPUT SHORT CIRCUIT.
The EPSX404 will shut down if there is a short circuit
condition on any one of the strobe heads. If the electrical
conductors connecting the power supply to the strobe heads are
exposed to water a short circuit will result. The first sign is
intermittent operation, followed by complete shutdown of the
strobe system. To find the short circuit, unplug all strobe head cables
from the EPSX404. Test one cable/head at a time until the problem is
found.Water shoring shows as a blue/green colored residue
where the short circuit has occurred.
WIRING DIAGRAM 2
FLASH PATTERN LIST CUTOUTS
ON/OFF AND FLASH PATTERN SELECTION
ON/OFF AND FLASH PATTERN SELECTION
INPUT CURRENT: 3.75A
www.eccogroup.com
MADE IN USA
WHITE FLASH
TOGETHER
RED: +V
BLACK: - GND
VIOLET: PATTERN SELECT
10A FUSE
1
2
3
1
2
3
1
2
3
3
2
1
1
2
3
ON/OFF
SWITCH
(10 AMP)
3 2 1
RED,
BLACK,
VIOLET
CONNECTOR
THESE LISTS MAY BE CUT-OUT AND USED
ON CUSTOM SWITCH PANELS, ETC.
Battery or nearby
chassis ground.
INPUT POWER: 50 WATTS
OUTPUT POWER: 40 WATTS
ALTERNATE
YELLOW FLASH
TOGETHER
Battery + or
Fuse Panel.
INPUT VOLTAGE: 10 to 30 Vdc
WARNING!
High Voltage
Please wait 5 minutes after
shutting this unit off before
attempting service.
RED
#
1
2
3
4
5
6
7
8
9
10
11
12
Flash Pattern
Random, Level 5
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Phased Mega Flash
Warble
Single-Double
Single-Quad
Cycle Flash
Description
Randomly selects from all patterns and runs each pattern 5 times.
Single Flash Alternating, 200 Flashes per minute.
2 Flash Bursts Alternating, 125 Double Flashes per minute.
3 Flash Bursts Alternating, 140 Triple Flashes per minute.
4 Flash Bursts Alternating, 140 Quad Flashes per minute.
5 Flash Bursts Alternating, 140 Quintuple Flashes per minute.
Single Flash alternating, 700 Flashes per minute.
Flash rate varies from 360 FPM to 860 FPM
6 Single Flashes at 450 FPM, 6 Single flashes at 860 FPM.
Single Flash, Double Flash combination.
Single Flash, Quad Flash combination.
Classic EPS Cycle Flash. Cycles through Double-Quad-Mega.
BLACK
VIOLET
POWER
HARNESS
PATTERN
SELECT
PATTERN SELECT SWITCH
IS A MOMENTARY, MORMALLY OFF,
LOW CURRENT Push-button SWITCH.
(CURRENT THROUGH SWITCH IS LESS THE 0.005A)
PRESSING PATTERN SELECT WILL INCREMENT
THE FLASH PATTERN.
PRESS AND HOLD PATTERN SELECT WHILE
TURNING THE POWER SWITCH ON TO RESET
FLASH PATTERN TO #1.
1
2
3
4
5
6
7
8
9
10
11
12
Random
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Phased Mega
Warble
Single-Double
Single-Quad
Cycle Flash
1
2
3
4
5
6
7
8
9
10
11
12
Random
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Phased Mega
Warble
Single-Double
Single-Quad
Cycle Flash
1
2
3
4
5
6
7
8
9
10
11
12
Random
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Phased Mega
Warble
Single-Double
Single-Quad
Cycle Flash
ACCESSORIES
The following accessories are available to make the installation of the
EPSX404 power supply even easier:
SWITCH-EPSX
ON/OFF with PATTERN SELECT push-button switch panel with 15
foot pre-wired harness. Provides the same function as WIRING DIAGRAM 2.
EPSX
ON
OFF
920-9071-00 REV. A
FLASH
PATTERN
1
2
3
4
5
6
7
8
9
10
11
12
Random
Single Flash
Double Flash
Triple Flash
Quad Flash
Quintuple Flash
Mega Flash
Phased Mega
Warble
Single-Double
Single-Quad
Cycle Flash
PAGE 2
">